HunterLab EasyMatch QC Color quality control software User Manual
PDF
Documento
Anuncio
Anuncio
User’s Manual for EasyMatch® QC Version 4.99 and Above Hunter Associates Laboratory 11491 Sunset Hills Road Reston, Virginia 20190 USA www.hunterlab.com A60-1012-402 Manual Version 3.8 EasyMatch QC User’s Manual Version 3.8 PREFACE Copyrights and Trademarks This documentation contains proprietary information of Hunter Associates Laboratory, Inc. Its reproduction, in whole or in part, without express written consent of Hunter Associates Laboratory, Inc. is prohibited. EasyMatch, Agera, Aeros, Vista, ColorFlex, MiniScan, and UltraScan are registered trademarks of Hunter Associates Laboratory, Inc. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Duraflect, Spectraflect, and Spectralon are trademarks of Labsphere, Inc. Teflon is a registered trademark of Dupont. LOVIBOND is a registered trademark of The Tintometer Ltd., UK Safety Notes For your safety when using your color measurement equipment, you should pay attention to the following types of statements in the hardware section of this User’s Manual. Each description is shown in its representative typeface. Caution: If the equipment is used in a manner not specified by HunterLab, the overall safety and protection provided by the equipment may be impaired. The instrument is for indoor use only and not suitable for a wet location. Caution: There is a potential UV Light hazard in using this instrument. Please avoid looking directly at the light. The frequency of this flashing light is in the range of sensitivity for those prone to epileptic seizures. For your safety when using HunterLab instruments, you should pay attention to the following types of statements in this User’s Manual: 2 ▪ General safety instruction that should be observed at all times while operating the instrument. ▪ Specific safety instruction critical to the type of instrument operation being explained in the manual where the caution appears. EasyMatch QC User’s Manual Version 3.8 ▪ Use of this equipment in a manner not specified by the manufacturer may impair the protection afforded by the equipment. ▪ Danger of electric shock if liquids are spilled and fire if volatile or flammable liquids are spilled. Use care when measuring liquid samples. Legal Disclaimers: Instrumental – Visual Evaluation The HunterLab Colorimetric Spectrophotometers are designed for precision color and appearance measurement. Each instrument measures numerical color and related data in absolute and relative terms. HunterLab cannot guarantee the accuracy, completeness, efficacy and timeliness of the data due to inherent uncertainties in instrumental readings, variations in sample presentation, and potential inconsistencies in human color perception. It is strongly advised that each user verify the instrumental data with meticulous visual evaluation. Disclaimer of Liability: Utilization of Data, Metadata and Information Hunter Associates Laboratory, Inc (including its employees, agents and assignees) assumes no responsibility for consequences from the use of the data derived from its spectrocolorimeters or from the information contained herein or in any respect for the content of such information including but not limited to errors or omissions, the accuracy or reasonableness of factual or scientific assumptions, studies or conclusions, the defamatory nature of statements, ownership of copyright or other intellectual property rights and the violation of property, privacy or personal rights of others. Hunter Associates Laboratory, Inc. is not responsible for and expressly disclaims all liability for damages of any kind arising out of use, reference to or reliance on such data and/or information. No guarantees or warranties, including but not limited to any express or implied warranties of merchantability or fitness for any particular use or purpose made by Hunter Associates Laboratory, Inc. with respect to such data and/or information. 3 EasyMatch QC User’s Manual Version 3.8 4 EasyMatch QC User’s Manual Version 3.8 Table of Contents PREFACE ...................................................................................................................... 2 Copyrights and Trademarks ..................................................................................................................... 2 Safety Notes............................................................................................................................................. 2 TABLE OF CONTENTS.................................................................................................... 5 GETTING STARTED WITH EASYMATCH QC ...................................................................11 What is EasyMatch QC? ......................................................................................................................... 11 How to Install EasyMatch QC ................................................................................................................ 11 Install the Software ................................................................................................................................ 11 Activate the SoftKey License .................................................................................................................. 13 Add the Sensor ...................................................................................................................................... 15 Standardization Setup ........................................................................................................................... 16 STANDARDIZATION ....................................................................................................17 Standardization of 45°/0° or 0°/45° ...................................................................................................... 17 Standardization of d/8° sphere ............................................................................................................. 18 Care of Instrument Standards ............................................................................................................... 20 Standard Tiles, Green Tiles and Black Glass ....................................................................................... 20 Fluorescent Standards........................................................................................................................ 20 Cleaning the Lens Surface and Didymium Filter ................................................................................ 21 Haze Standard Care ............................................................................................................................ 21 SOFTWARE FEATURES .................................................................................................23 Jobs ........................................................................................................................................................ 23 Toolbar Buttons ..................................................................................................................................... 24 Job Conventions .................................................................................................................................... 24 Templates .............................................................................................................................................. 25 Data Views ............................................................................................................................................. 26 Job Tree .............................................................................................................................................. 26 5 EasyMatch QC User’s Manual Version 3.8 Color Data Table ................................................................................................................................. 31 2D Color Plot ...................................................................................................................................... 38 3D Color Plot ...................................................................................................................................... 42 Color Render ...................................................................................................................................... 44 EZ View ............................................................................................................................................... 46 Memo View ........................................................................................................................................ 49 Spectral Data Table ............................................................................................................................ 51 Spectral Plot ....................................................................................................................................... 54 Trend Plot ........................................................................................................................................... 56 Database............................................................................................................................................. 59 Keyboard Shortcuts ............................................................................................................................... 60 Commands from an Open File Menu: ................................................................................................ 61 Commands from an Open Edit Menu: ............................................................................................... 62 Commands from an Open View Menu: ............................................................................................. 62 Commands from an Open Measurements Menu: ............................................................................. 62 Commands from an Open Options Menu: ......................................................................................... 62 Commands from an Open Sensor Menu: .......................................................................................... 63 Commands from an Open Window Menu: ........................................................................................ 63 Commands from an Open Help Menu: .............................................................................................. 63 THE FILE MENU ...........................................................................................................65 File > New Job ........................................................................................................................................ 65 File > Default Job ................................................................................................................................... 65 File > Open Job ...................................................................................................................................... 65 File > Open Job Template ...................................................................................................................... 65 File > Recall Measurement from Database ........................................................................................... 66 Recall .................................................................................................................................................. 66 Auto DB Search................................................................................................................................... 68 Recall from Common DB .................................................................................................................... 69 File > Delete Measurement from Database .......................................................................................... 69 File > Close Job....................................................................................................................................... 71 File > Save Job ........................................................................................................................................ 72 File > Save Job As ................................................................................................................................... 72 File > Save Job Template ....................................................................................................................... 72 File > Save Job Template As ................................................................................................................... 72 File > Apply Template to Job ................................................................................................................. 73 6 EasyMatch QC User’s Manual Version 3.8 File > Save Measurement to Database .................................................................................................. 73 File > e-Signature (-ER Version Only) ..................................................................................................... 73 File > Configure Company Logo ............................................................................................................. 73 File > Header/Footer Setup ................................................................................................................... 74 File > Print Job Setup ............................................................................................................................. 75 File > Print Job Preview.......................................................................................................................... 76 File > Print Job ....................................................................................................................................... 77 File > Printer Setup ................................................................................................................................ 77 File > Page Setup.................................................................................................................................... 78 File > Import QTX Format ...................................................................................................................... 78 File > Export ........................................................................................................................................... 78 QTX Format ........................................................................................................................................ 78 File > Email ............................................................................................................................................. 79 File > Time Synchronization (-ER Version Only) .................................................................................... 80 File > Database ...................................................................................................................................... 80 Backup Database ................................................................................................................................ 80 Universal Database Import ................................................................................................................ 80 Create New Database......................................................................................................................... 81 Import Textiles Database ................................................................................................................... 82 File > Log Off .......................................................................................................................................... 83 File > Most Recently Opened Jobs......................................................................................................... 83 File > Exit ................................................................................................................................................ 83 THE EDIT MENU ..........................................................................................................85 Edit > Cut ............................................................................................................................................... 85 Edit > Copy ............................................................................................................................................. 85 Edit > Paste ............................................................................................................................................ 85 Edit > Delete .......................................................................................................................................... 85 7 EasyMatch QC User’s Manual Version 3.8 THE VIEW MENU .........................................................................................................87 View > Toolbar ....................................................................................................................................... 87 View > Status Bar ................................................................................................................................... 88 View > Job Tree...................................................................................................................................... 89 View > Audit Log (-ER Version Only)...................................................................................................... 89 View > Event Log (-ER Version Only) ..................................................................................................... 90 THE MEASUREMENTS MENU ......................................................................................93 Measurements > Read Standard ........................................................................................................... 93 Measurements > Read Sample .............................................................................................................. 93 Measurements > Read Series ................................................................................................................ 94 Y, x, y Chromaticity Plot for Highway Safety Colors (ASTM 4956) ..................................................... 94 Measurements > Average ..................................................................................................................... 97 Measurements > Timed Read................................................................................................................ 98 Measurements > Automatic Standard Search ...................................................................................... 98 Measurements > Average Selected to Measurement .......................................................................... 99 Measurements > Average Selected to Standard ................................................................................... 99 Measurements > Average Selected to New Standard .......................................................................... 99 THE OPTIONS MENU ................................................................................................. 101 Options > Naming Conventions ........................................................................................................... 101 Options > Average Method ................................................................................................................. 103 Options > Read Method ...................................................................................................................... 104 Options > Configure Timed Read......................................................................................................... 106 Options > Configure Automatic Standard Search ............................................................................... 107 Options > Default Tolerances .............................................................................................................. 107 Options > Adjust Scale Factors ............................................................................................................ 110 Options > ASCII Export ......................................................................................................................... 111 8 EasyMatch QC User’s Manual Version 3.8 Options > Data Send ............................................................................................................................ 112 Options > Custom Indices .................................................................................................................... 114 Options > Application Preferences ...................................................................................................... 115 Options > External Trigger ................................................................................................................... 118 Choose Target .................................................................................................................................. 119 Communication ................................................................................................................................ 119 Standardization ................................................................................................................................ 119 Read Command ................................................................................................................................ 120 Commands for Triggering Device ..................................................................................................... 120 Options > System Configuration .......................................................................................................... 121 Access Privileges............................................................................................................................... 121 Data Storage ..................................................................................................................................... 125 Server Settings (ER Version Only) .................................................................................................... 126 e-Signature Settings (ER Version Only) ............................................................................................ 127 Options > Customize Toolbar .............................................................................................................. 127 Options > EasyGroup ........................................................................................................................... 127 Options > Import EasyGroup Sequence .............................................................................................. 127 THE SENSOR MENU................................................................................................... 129 Sensor > Install/Configure ................................................................................................................... 129 Sensor > Standardize ........................................................................................................................... 131 Sensor > Set Modes ............................................................................................................................. 132 Sensor > Set Interval ............................................................................................................................ 133 Sensor > UV Calibration ....................................................................................................................... 133 Sensor > Configure Multi Mode .......................................................................................................... 135 Sensor > Import Logged Reads ............................................................................................................ 136 Sensor > Configure Setups ................................................................................................................... 137 Download ......................................................................................................................................... 137 Edit ................................................................................................................................................... 137 Sensor > Diagnostics ............................................................................................................................ 138 Green Tile Test ................................................................................................................................. 138 Repeatability Test............................................................................................................................. 140 9 EasyMatch QC User’s Manual Version 3.8 Didymium Filter Test ........................................................................................................................ 142 Advanced Diagnostics ...................................................................................................................... 145 Predictive Diagnostics ...................................................................................................................... 147 THE WINDOW MENU ................................................................................................ 148 Window > New Window ...................................................................................................................... 148 Window > Cascade .............................................................................................................................. 148 Window > Tile ...................................................................................................................................... 149 Window > List of Open Jobs ................................................................................................................ 149 THE HELP MENU ....................................................................................................... 150 Help > Help Topics ............................................................................................................................... 150 Help > HunterLab on the Web ............................................................................................................. 150 Help > About ........................................................................................................................................ 150 Help > License Information.................................................................................................................. 150 APPENDIX A: SOFTWARE MESSAGES......................................................................... 152 APPENDIX B: CREATING AND CONFIGURING A SQL DATABASE ................................ 154 FIGURES .................................................................................................................... 158 INDEX ....................................................................................................................... 164 10 EasyMatch QC User’s Manual Version 3.8 Getting Started with EasyMatch QC What is EasyMatch QC? EasyMatch QC is a comprehensive color quality control package designed for 32- or 64-bit Windows Operating Systems. The software allows you to control your spectrophotometer instrument, make color measurements, and display, print, and store results, both in spreadsheet format and graphically. How to Install EasyMatch QC Confirm that the computer meets the following minimum requirements: Table1: Minimum Computer Requirements Component Minimum Requirements for EasyMatch QC 4.88 and above Operating System Windows 7, 32+64 bit, Ultimate or Professional Windows 8, 8.1 64 bit, Ultimate or Professional Windows 10, 64 bit, Professional Windows 11 Processor RAM 1.0 gigahertz (GHz) or faster, 32-bit (x86) or 64-bit (x64) processor 4 gigabyte (GB) RAM (32-bit) or 4 GB RAM (64-bit) Hard Drive 120 GB minimum Hard Disk Space; 256 BG is recommended DVD/CD DVD/CD or CD Optical Drive* COM Ports Multiple COM ports, including at least one available USB or Serial port for sensor. If the Sentinel Key is still used - one additional USB port for software key** Network Card Network Card 10/100 Monitor 19-inch or larger Color (110V/220V) supported by Video Card Printer A hard copy printer for reporting data and diagnostic test results is useful but not required. *Software can be provided via thumb drive or dropbox for computers without these drives. **Required only for legacy customers still using a Sentinel key. Install the Software Complete the following steps: 1. Log into the system using an account that has full ‘Administrator’ privileges for the PC — network or local. If any antivirus package is installed, please close/disable protection for installation. Antivirus software can be reenabled after installation. 2. Insert the installation CD into the CD-ROM drive or insert the flash drive into a USB port to install the software. 3. For the CD: Select the Easy Match QC Icon or from Windows, go to START > RUN >EZMQC_MENU and OPEN. The following screen will be shown. 11 EasyMatch QC User’s Manual Version 3.8 Figure 1. EasyMatch Installation For the Flash Drive: Go to the folder for EasyMatch QC and click on this file to begin installation - EasyMatch QC-Setup.exe. The manuals and the softkey license are also included on the flash drive and can be copied into the PC or network location. Figure 2. Installation for Flash Drive 4. Select INSTALL EASYMATCH QC SOFTWARE and follow the screen prompts. 5. Select SOFTKEY LICENSE as the type of key to use with the software. Note: You can select Sentinel Key to use if you have this key from a previous purchase. Figure 3. Software Key License 12 EasyMatch QC User’s Manual Version 3.8 6. When the EasyMatch QC installation is finished, select the OPTION BUTTON next to YES, I WANT TO RESTART MY COMPUTER NOW and then FINISH to restart the computer and log back in. Figure 4. Completed Install 7. The CD or flash drive can now be removed. Activate the SoftKey License 1. From the Desktop, select the EasyMatch QC Icon or from the Windows Start menu, choose the following to open the software: START > PROGRAMS > HUNTERLAB > EASYMATCH QC 2. A warning message to activate the license will be displayed as shown in Figure 4. Note: EZMQC functions are unavailable before key activation. Figure 5. No License Warning 3. The SoftKey License is uniquely associated with the sensor serial number and is provided on a thumb drive supplied with EasyMatch QC or via email from HunterLab. 4. Go to HELP > LICENSE REGISTRATION > ACTIVATION. 5. Select ACTIVATE LICENSE. 13 EasyMatch QC User’s Manual Version 3.8 Figure 6. Activate License i. Option #1: Key ID. This method is for copying the ID from an email or writing down the 32-digit code. This requires an internet connection. a. From the CHOOSE AN OPTION page (Figure 5), select KEY ID. b. Paste-in or type-in the License Key ID and click ACTIVATE. c. An acknowledgement will be displayed showing the activation status. ii. Option #2: Key File (.skl) This method is for using the SoftKey License (.skl file) on the thumb drive. a. Place the thumb drive with the SoftKey License in the USB port. b. From the CHOOSE AN OPTION page (Figure 5), select KEY FILE (.skl). c. Browse the USB to find the SoftKey License (.skl) file, then click ACTIVATE. d. An acknowledgement will be displayed showing the activation status. iii. Option #3: Sentinel Key a. If the user has a HunterLab USB hardware key, then it can be used with a new sensor on the same computer. Return to Install the Software, Step 5 (Figure 2), and select SENTINEL KEY to continue. iv. Option #4: 30-day trial a. Fill out the registration form provided for the 30-day trial. Connect to the internet. HunterLab will approve the trial and email the SoftKey license back. Follow the directions for Option #1 or #2 to complete. 14 EasyMatch QC User’s Manual Version 3.8 Figure 7. Request 30-day Trial Add the Sensor 1. Upon initial startup, the following message will be displayed: SENSOR NOT YET INSTALLED. PLEASE INSTALL A SENSOR TO TAKE MEASUREMENTS. This message will remain until you proceed to the Install/ Configure command in the Sensor menu and install a new sensor. 2. The Sensor Manager appears first: Figure 8. Sensor Manager 3. Select ADD SENSOR to install a new sensor. The Setup Sensor screen allows selection of the instrument model and the communications port. Select NEXT when ready. Figure 9. Setup Sensor 15 EasyMatch QC User’s Manual Version 3.8 Note: If using a typical 9-pin serial cable for communications between the sensor and PC, select COM1. If using USB-to-serial adapter, then select the highest number COM Port No. offered. If using USB communications, the COM port will automatically be selected. Standardization Setup 1. Next, configure a Standardization Mode for the sensor. Select the TYPE of MODE, a NAME for the MODE, the AREA of VIEW and the UV FILTER POSITION. Figure 10. Setup Mode 2. Select the option next to STANDARDIZE NOW to proceed immediately to standardization upon completion of sensor configuration. Select NEXT to complete the installation. Restart EZMQC to get sensor info saved and get the database updated correspondingly. 16 EasyMatch QC User’s Manual Version 3.8 Standardization Standardization sets the top and bottom of the photometric scale. During standardization, the bottom of the scale is set first. For this, you simulate the case where all the light is absorbed by the sample. Tools used to set the bottom-of-scale include a black glass, light trap or black card. The top-of-scale is then set by measuring the light which is reflected from or transmitted through a calibrated standard. This is done using a calibrated white tile for reflectance measurements and air or a solvent-filled cell for transmittance measurements. Standardization can be done through EasyMatch QC by selecting SENSOR > STANDARDIZE or by clicking the STANDARDIZE button on the default toolbar). Re-standardization is recommended per the interval in Table 2. An overview of HunterLab instruments and their standardization modes are shown below in Table 2. Table 2. HunterLab Instrument Modes & Geometry Directional Standardization Reflectance Interval Aeros X 8 hours ColorFlex EZ X 4 hours Agera X 8 hours LabScan XE X 8 hours Instrument MiniScan EZ 4000 Geometry: Diffuse TTRAN/ RSIN RSEX RTRAN 4 hours X MiniScan EZ 4500 X 4 hours UltraScan PRO X X X 8 hours UltraScan VIS X X X 8 hours X 8 hours Vista Instrument Geometry: As referenced in CIE Publication 15:2018, the geometry of an instrument defines the relative position of light source, sample plane and detector. There are two broad categories of instrument geometries - directional and diffuse. Instrument Mode: For an instrument of a defined geometry, a mode is a configuration of the optical path of the sensor that defines all optical elements such as sample measurement position at the reflectance port in RSIN specular-included or RSEX specular-excluded, or at the TTRAN or RTRAN transmittance ports. Standardization of 45°/0° or 0°/45° Standardization on an instrument with 45°/0° or 0°/45° geometry requires reading of the black glass and the calibrated white tile that are contained in the standards box. . 17 EasyMatch QC User’s Manual Version 3.8 Figure 11. LabScan Standardization Note: It is highly recommended that a Green Tile test be performed after standardization. Do not proceed without successfully passing the Green Tile Test. If needed, contact the Service Department of HunterLab. For more instruction on the Green Tile Test click here. Standardization of d/8° sphere To standardize for reflectance measurements and set the Bottom-of-scale, place the light trap at the reflectance port. Figure 12. Standardizing on the Light Trap to set Bottom-of-Scale To standardize for Total Transmittance (TTRAN) measurements, place the light blocker card inside the transmittance chamber at the sphere side and set the bottom-of-scale. This is shown in the next photo. The transmittance compartment door may be closed or left open. 18 EasyMatch QC User’s Manual Version 3.8 Figure 13. Setting Bottom-of-Scale for RTRAN To standardize for Regular Transmittance (RTRAN) measurements and set the bottom-of-scale, place the light blocker inside the transmittance chamber over the lens as shown in the figure below. Figure 14. Setting Bottom-of-scale for RTRAN Mode To set the top-of-scale, measure the white tile at the reflectance port with the Transmittance Chamber closed. Figure 15. Setting Top-of-Scale with the White Tile 19 EasyMatch QC User’s Manual Version 3.8 When standardizing in transmittance modes you are prompted to place the white calibrated standard at the reflectance port. Alternatively, a plug of barium sulfate (BaSO4) or magnesium oxide (MgO) may be used to approximate the actual sphere wall. When taking transmittance measurements, the calibrated white tile or the plug used during standardization must be kept at the reflectance port. When the instrument is to be used for transmittance measurements of liquids, a clear liquid (distilled water for water-based samples, toluene or benzene for resins, or mineral oil for oils) in a cell of the desired size should be used to set the top-of-scale. Place the cell in the transmittance compartment as close to the sphere as possible for measuring total transmittance. Place it as close to the lens as possible when measuring regular transmittance. Note: Closing the transmittance compartment door while making transmittance measurements is the best practice for this instrument. However, when measuring the transmittance of liquids that are volatile and/or toxic, it may be more important to measure the samples quickly than to eliminate ambient room light. To see if leaving the door open will adversely affect your color measurements, standardize the instrument in the desired transmittance mode with the transmittance compartment door closed, then measure either air or a typical sample with the door open and then with the door closed. Compare the measurements. If the difference is acceptable under your measurement method, you may measure your samples with the door open. This test should be repeated if the instrument is moved to a new location. Note: It is highly recommended that a Green Tile test be performed after standardization. Do not proceed without successfully passing the Green Tile Test. If needed, contact the Service Department of HunterLab. For more instruction on the Green Tile Test click here. Care of Instrument Standards It is important that the standards be treated with extreme care. When a standard is used, center it carefully at the measurement port. Never use a calibrated standard to back samples being measured. The sample clamp or a white uncalibrated tile should be used as a backing. When not using the standards, keep them in the standards case. Inspect the standards for dust and fingerprints before standardizing your instrument. If using a white tile and black glass for standardization, inspect these tiles for dust and fingerprints. Do the same for the diagnostic green tile prior to running the green tile test. If a tile is lost or damaged, contact HunterLab concerning replacement. Note: significant scratches may cause standardization to be in error. Standard Tiles, Green Tiles and Black Glass HunterLab uses a variety Instrument Standards to meet the precise needs of each product, i.e. Opal Glass, Ceramic Glass, Porcelain Enamel on Steel, or PTFE coated Steel. Recommended cleaning instructions are specific to each type of standard. Please refer to the Instrument Manual for cleaning instructions. If using a light trap, please keep it in the standards case when not in use to prevent it from becoming scratched or collecting dust. Before standardizing, check the light trap for scratches and dust. Fluorescent Standards The fluorescent standard used with the UV control option must be cleaned as well. This Spectralon standard may be air brushed with a jet of clean, dry air or nitrogen, NOT FREON. If air brushing is insufficient, sand the standard under running water with 220-240 grit waterproof emery cloth until 20 EasyMatch QC User’s Manual Version 3.8 water immediately beads and runs off the surface. Then blow the standard dry with clean air or nitrogen. Cleaning the Lens Surface and Didymium Filter The lens and filter may be cleaned using photographic-quality lens solution and lens paper. Put a few drops of solution on the lens paper and gently wipe the lens or filter in a circular motion for a few seconds. Then wipe the lens or filter with a dry lens paper to remove streaks and any hazy film. Haze Standard Care HunterLab provides the following information to customers purchasing Haze Standards and is the proper method for handling and cleaning the standards: • Haze standards must be kept clean to ensure the accuracy of the measurement. • Standards may be cleaned with cold water and mild dish washing detergent. • Never use harsh solvents, alcohol, or aggressive cleaners! • Never rub the surface of the standards when they are dry. • Use compressed air to remove dust or to dry after washing. • Never store standards near harsh chemicals or solvents. • Standards should be stored covered in their box in a cool, dry place. • Use caution when handling the standards as fingerprints will affect the readings. • Standards should be validated on an annual basis to ensure accuracy. 21 EasyMatch QC User’s Manual Version 3.8 22 EasyMatch QC User’s Manual Version 3.8 Software Features The sections below examine some of the most important concepts and features related to operation of EasyMatch QC. Jobs A job is a collection of all the data views (displays) and measurements (standards and samples) that you use for a task, product, or customer. Jobs are the documents of EasyMatch QC, analogous to word processing documents containing text and its formatting or spreadsheet documents containing fields of data and formulas. If you wanted to transfer a job to another computer or another user who also has EasyMatch QC, the job file (with a .JSD file extension) would contain all the information needed to examine and/or reproduce your results. You can create new jobs for many reasons, such as to hold data for a certain customer or a specific product line. Each operator may maintain his own job with his own preferences, or you can create separate jobs for different operations, such as measuring plastic pellets before extrusion and then the final extruded product. You can be creative in maintaining and organizing your job files. You may have multiple jobs open and in use at the same time; each job will be shown as a separate tab on your screen. You can switch easily between jobs by clicking the tab of the job you wish to see. To set up a job, you will need to complete the following tasks: 1. OPEN the new job. 2. SAVE the job under the desired name. (Long file names and spaces are acceptable.) 3. CONFIGURE the desired data views (see the ‘Data Views’ section), including setting the location, size, shape, and properties of each view on the screen. 4. READ or recall the desired standard and samples into the job and view the results. The number of standards and samples that can be housed in a single job is virtually unlimited—restricted only by the amount of memory available on the computer. It is difficult to picture a job file, but a screen capture of a job is provided below as an illustration. Standard Color Data Display Samples Color Plot Display Job Name Spectral Plot Display Figure 16. Parts of a Job As you can see on the tab, this job is called GREEN. You can see that the job contains a standard called STANDARD 1 and four numbered samples. A 2D Color Plot has been configured to display the CIELAB color scale for D65/10° with a colored background. The Color Data Table display is displaying L*, a*, b*, and dE* for the 23 EasyMatch QC User’s Manual Version 3.8 samples related to the standard. The Spectral Plot is displaying spectral reflectance at 10 nm increments with the colored background. The location, size, and shape of each view are also saved as part of the job, along with the measurements and the properties of each view. A second job, called YELLOW is contained on the tab behind this one and you can switch to it simply by clicking the tab at the bottom of the screen. Toolbar Buttons The toolbar at the top of the screen provides quick access to many functions in EasyMatch QC via its buttons. All functions incorporated into the toolbar may also be accessed through the drop-down menus. The default buttons on the toolbar are shown below in order from left to right on the toolbar, along with a brief explanation of each button's function. The functions of the buttons may be altered, if desired, using the OPTIONS > CUSTOMIZE TOOLBAR command. Default Toolbar Buttons Icon Function Opens a New Job Open an Existing Job. Prints the Current Job Print Preview Saves the Current Job. Reads a Standard Reads a Sample Instrument Standardization. Sensor Diagnostics Logs the Current User Out Opens the Html Help File. Job Conventions Although great flexibility has been incorporated into the concept of a job, there are some attributes that all jobs will share. • 24 Each individual job may contain all the information necessary to complete that job if the operator has included that data. All information recalled from the database or read in through the instrument for use in that job will be saved with that job. EasyMatch QC User’s Manual Version 3.8 • When you open a job, it will reappear looking the same as when it was last closed. Note: It is recommended that you back up your database, job, and template files periodically, particularly prior to upgrading or making other major changes to your system computer. Templates JOB TEMPLATES can be thought of as subsets of jobs. They contain some of the pieces of information contained in jobs, but not all of them. Templates are analogous to style lists or style sheets that are available in some word processing and desktop publishing programs because they can be used to control the cosmetic appearance of a job. A template houses configuration information for the data views and screen, such as locations, sizes, shapes, and properties, but does not contain any measurements. A template is saved whenever a job is saved. A template is meant to be used as a starting point in creating a new job when the same views are used for many jobs. You can then fill the template with measurements and configuration settings. Several application-specific templates are installed with EasyMatch QC. These templates provide a starting point for new jobs. To set up a TEMPLATE, you will need to complete the following tasks: 1. OPEN A NEW JOB. 2. CONFIGURE THE DESIRED DATA VIEWS. This includes setting the location, size, shape, and properties of each view on the screen. 3. CONFIGURE THE DESIRED OPTIONS you wish to use for this template using the OPTIONS menu. 4. SAVE THE JOB as a template using the SAVE JOB TEMPLATE AS command in the FILE menu. The extension for a template is .JTP. Whenever you want to use a template to create a new job, simply choose the FILE > OPEN JOB TEMPLATE command, choose the desired template from the list of available templates, fill the template with your measurements, and SAVE it as a job. To apply a template to an existing job, choose the FILE > APPLY TEMPLATE TO JOB and the configuration of the job screen will adjust to match the template while retaining the measurements. The types of information a template may house are illustrated in the picture below. Figure 17. Example of a Template 25 EasyMatch QC User’s Manual Version 3.8 Templates contain no standards or samples. The measurements would be added to the job as they are made. The screen configuration and options for each data view comprise the template and will be part of any job created using the template. There are four menu options allowing you to utilize templates: OPEN JOB TEMPLATE, SAVE JOB TEMPLATE, SAVE JOB TEMPLATE AS, and APPLY TEMPLATE TO JOB. Note: It is recommended that you back up your database, job, and template files periodically, particularly prior to upgrading or other major changes to your system computer. Data Views Each of the smaller panes shown on a job tab is a data view. Each data view displays unique information about the standard and/or samples. You may resize any data view to fill as much or as little of the screen as you like. The types of data views that are available are: • Job Tree • Color Data Table • 2D Color Plot • 3D Color Plot • Color Render • EZ View • Memo View • Spectral Data Table • Spectral Plot • Trend Plot These views are described in the subsections below. Job Tree The information displayed in the Job Tree view includes the name of each standard and each sample contained in the job. Samples affiliated with a standard will be shown as branches under the standard. Note: The Job Tree is only visible when Job Tree is checked in the View menu. 26 EasyMatch QC User’s Manual Version 3.8 Figure 18. Job Tree Single or multiple items may be highlighted in this view. Click the + next to an item to open the branches below it or the - sign to close the branches. Click the left mouse button on any item to highlight it. To highlight multiple items, hold the CTRL KEY while clicking on EACH DESIRED ITEM or hold the SHIFT KEY and click on the FIRST and LAST items desired to highlight all items in between. Then click the right mouse button for various options concerning the highlighted items. These options are described below. In addition, the items that are highlighted in the Job Tree are those displayed in the other views in the job. Note: To keep data views clean and not cluttered, and for speed of measurements, it is recommended that you limit the number of items highlighted in the Job Tree at any one time to 500 or less. • CUT: This command removes the highlighted items from the Job Tree and from the job and places them on the Windows clipboard. If desired, the cut items may then be pasted into another job using the PASTE command. • COPY: This command copies the highlighted items from the Job Tree to the Windows clipboard. If desired, the copied items may then be pasted into another job using the PASTE command. Items may also be dragged and dropped from one job to another to copy and then paste them. • PASTE: This command allows you to place items previously cut or copied to the Windows clipboard onto the Job Tree and into this job. Items may also be dragged and dropped from one job to another to copy and then paste them. • DELETE: This command allows you to permanently delete the currently highlighted items from the Job Tree and from the job. No copies of the items are kept on the Windows clipboard. • PROPERTIES: This command allows you to view the measurement properties of the currently highlighted item. If the standard or sample is the result of averaging several readings, the standard deviation and range of those readings are included. For standards, you may also set tolerances for as many scales, indices, and differences in as many illuminant/observer combinations as you wish and/or indicate hitch factors to apply to the standard and its samples. 27 EasyMatch QC User’s Manual Version 3.8 Figure 19. Properties of a Standard Figure 20. Tolerances See the DEFAULT TOLERANCES section in the OPTIONS MENU chapter for instructions on setting tolerances. Figure 21. Hitch Standardization 28 EasyMatch QC User’s Manual Version 3.8 Figure 22. Setting Up a Hitch Standard • SHOW THIS ITEM ONLY: This command appears for standards only and causes the chosen standard and its associated samples alone to be displayed in the Job Tree. All other standards and samples are removed from the Job Tree display. • COPY SAMPLE TO STANDARD: This command appears for samples only and causes the highlighted sample measurement to replace the current standard measurement in the Job Tree, while retaining the sample’s ID. • COPY SAMPLE TO NEW STANDARD: This command appears for samples only and causes the highlighted sample measurement to be added to the job as a standard as well, while retaining the sample’s ID. • COPY STANDARD TO SAMPLE: This command appears for standards only and causes the highlighted standard measurement to be placed in the Job Tree as a sample on that standard’s branch. You are given the opportunity to name the new sample. • COPY STANDARD TO NEW STANDARD: This command appears for standards only and causes the highlighted standard measurement to be added to the job as a second instance of the standard, while retaining the original standard’s ID. When the right mouse button clicks on an open area of the Job Tree view (an area other than a sample or standard), further commands are available, as follows: • PRINT PREVIEW: This command shows on-screen what the Job Tree will look like when printed. Figure 23. Print Preview 29 EasyMatch QC User’s Manual Version 3.8 • PRINT THIS VIEW: This command prints the Job Tree view in a fashion similar to that shown below. Figure 24. Printing the Job Tree • ICON SIZES: Choosing this command allows you to choose to display small icons, large icons, or no icons to represent each standard and sample in the Job Tree. • SHOW ALL ITEMS: This command opens all the branches of the Job Tree so that every standard and sample is visible. • ENTER STANDARD DATA: This command allows you to hand enter colorimetric or spectral data to create a new standard. Figure 25. Enter Colorimetric Data for a Standard 30 EasyMatch QC User’s Manual Version 3.8 Figure 26. Entering Standard ID • ENTER SAMPLE DATA: This command allows you to hand enter colorimetric or spectral data to create a new sample. Figure 27. Entering Spectral Data for a Standard Figure 28. Entering Sample ID • COLLAPSE THE TREE: This command closes all the branches of the Job Tree so that only the standards are visible. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. Color Data Table The Color Data Table view shows COLOR SCALE, COLOR DIFFERENCE, and INDICE DATA for the standards and samples in the job. The items in the Color Data Table may be sorted by clicking the column header (for row major) or row header (for column major) of interest. 31 EasyMatch QC User’s Manual Version 3.8 Figure 29. Color Data Table Click on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • COPY TO CLIPBOARD: Before you initiate this command, you must highlight one or more of the samples and standards shown in the spreadsheet. When COPY TO CLIPBOARD is then selected, the highlighted data is then copied to the Windows Clipboard. If desired, the copied data may then be pasted into another application (such as Microsoft Excel) using its PASTE command. Figure 30. Configure the Color Data Table • 32 CONFIGURE: This command allows you to set various preferences pertaining to the Color Data Table view. Select each SCALE, DIFFERENCE, INDICE, and TEXT field parameter you would like to display from the drop-down boxes and click the LEFT ARROW (<<) button after each selection to move it to the SELECTED ITEMS box. Once all desired items are shown in the Selected Items box, you may move them up and down in the display order using the up and down arrows. Items may also be removed from the Selected Items box using the REMOVE button. EasyMatch QC User’s Manual Version 3.8 Highlight (select) each ILLUMINANT/OBSERVER combination you wish to display. Choose your STATISTICS the same way. You may indicate the order in which you would like the illuminant/observer tabs and statistical parameters displayed by deselecting all items that have already been chosen and then selecting the items for display in the order desired. Configure other settings at the bottom right of the screen. When DISPLAY LATEST DATA FIRST is checked, the most recent reading is shown at the top of the display rather than the bottom. When AUTO SIZE CELLS is checked, the spreadsheet cells will be automatically sized based on the data contained in them. You may also insert custom fields into the Color Data Table using the INSERT CUSTOM FIELD button. These fields may consist of data obtained from outside EasyMatch QC or calculated formulas. Follow the instructions below to insert a custom field. • CUSTOM DATA FIELD 1. Click INSERT CUSTOM FIELD. The Configure Custom Field box appears. Figure 31. Configure Custom Field 2. Click the RADIO BUTTON next to DATA FIELD and then the RADIO BUTTON next to NEW. Type a label for the data field into the LABEL BOX. In this example, ‘oven temperature’ was used. Figure 32. Select a Custom Label 3. Click OK. Add DATA FIELDS to your display as a text field, then click OK from the Color Data Table Configuration screen. The Oven Temperature field is added to the Color Data Table. 33 EasyMatch QC User’s Manual Version 3.8 Figure 33. Custom Field Added to Color Data Table 4. Enter the oven temperature for each item desired by RIGHT-CLICKING on the item in the JOB TREE > ENTER OVEN TEMPERATURE DATA from the menu that appears. Oven Temperature will be replaced by whatever label was entered on the Configure Custom Data screen. Once you click OK, the entered data will be displayed. Figure 34. Inserting Data for Custom Field Figure 35. Display of Data for Custom Field • Custom Formula Field 1. Click INSERT CUSTOM FIELD. The Configure Custom Field box appears. Figure 36. Custom Field Configuration 2. Click the RADIO BUTTON next to FORMULA FIELD. TYPE A LABEL for the formula field into the LABEL BOX. In this example, ‘ABC Index’ was used. 34 EasyMatch QC User’s Manual Version 3.8 Figure 37. Label for Formula Field 3. Click OK. The Configure Formula Field box is shown. 4. Select an index type (i.e., Number only or Text only) in the following dialog. Figure 38. Enter Custom Formula Numeric data only and text data only are supported in formula field. Formula cannot support both numeric and text data at the same time for one index. If text is selected, then only the non-numeric data in result are allowed. For example, IF(H#>55, "Very Bright", IF(H#>41, "Bright", IF(H#>28, "Intermediate", IF(H#>10, "Tanned", IF(H#>-30, "Brown"). The result for this equation will be strings like Very Bright, Bright, Intermediate, Tanned, and Brown. Figure 39.Measurements with Text Criteria TYPE THE FORMULA. Place your CURSOR IN THE FORMULA BOX at the top of the screen and type ‘= ‘(equals). Further information follows. A formula is a text string defining how the value of the cell is to be calculated. A cell is referenced in a formula by specifying the column letter and then the row number. The columns are counted as A to Z from left to right of the spreadsheet. The rows are numbered from 1 to n from the top of the spreadsheet down. For instance, the top left cell of the spreadsheet is ‘A1.’ You may use the pound sign (#) instead of a column letter or row number to indicate that you wish to use the same row or column 35 EasyMatch QC User’s Manual Version 3.8 as the cell containing the formula. For instance, in the example below, ‘C#’ indicates that the same formula will apply to each cell of the column in which the formula was entered, using the data from Column C’s cell in the same row. It is useful to specify formulas in this manner if you want to assign formulas to entire rows or columns. Note: The row or column letter or number for each parameter selected in the Color Data Configuration was shown after that parameter in the Selected Items box. Figure 40. Display of Custom Formula in the Field The operators you may use in your formulas are: + ^ * / & | ! > < = : Addition Subtraction Power operator Multiplication Division Logical And Logical Or Negation Greater than Less than Equality Sum a range of cells. Use parentheses as necessary to indicate the desired order of operations. The functions you may use in your formulas include: ABS(Coord) Returns the absolute value of the cell. ADD(a,b) Adds the two elements. ACOS(Coord) Returns the arccosine of the value in the cell ASIN(Coord) Returns the arcsine of the value in the cell ATAN(Coord) Returns the arctangent of the value in the cell AVERAGE(a:b) Averages the range of cells COS(Coord) Returns the cosine of the value in the cell EXP(X) Returns raised to the power X IF(a,b,c) If a is true, cell is assigned b, else assigned c. LOG10(Coord) Returns the logarithm (base 10) of the value in the cell LN(Coord) Returns the natural logarithm of the value in the cell MAX(a:b) Returns the largest of the cell values MEDIAN(a:b) Returns the median of the cell values MIN(a:b) Returns the smallest of the cell values 36 EasyMatch QC User’s Manual Version 3.8 NEG(Coord) Returns the negative of the value in the cell. NOT(Coord) Returns the logical NOT of the cell's value PI Pi (3.14159...) POWER(B, P) Returns base B raised to power P RADIAN(Coord) Converts the value in the cell from degrees to radians SIN(Coord) Returns the sine of the value in the cell SQRT(Coord) Returns the square root of the value in the cell SQUARE(Coord) Returns the square of the value in the cell STDEV(a:b) Returns the standard deviation of the range of cells TAN(Coord) Returns the tangent of the value in the cell. Following are examples of valid formulas. A1:A10 Sums the first column, rows 1 through 10. 3.1415*C6 Pi times the value in C6. A#*G# The cell in column A, this row, multiplied by the value of the cell at Column G, same row. (A1+B1)*C1 Adds the first two cells and multiplies the result by the third. IF(A1>5, A1*2, A1*3) If the contents of A1 are greater than 5, then multiply A1 by 2, else multiply A1 by 3. Remember that your formulas are based on cell location, NOT the value in the cell (i.e., your formula uses cell C1, regardless whether L, a, or b values are in it.) If you reconfigure your display, you may need to adjust your formula. Click SET FORMULA, then OK. Add FORMULA FIELDS to your DISPLAY as a TEXT FIELD, then click OK from the Color Data Table Configuration screen. The formula will fill cells as indicated. Figure 41. Color Data Table with Custom Fields • PRINT PREVIEW: This command shows on-screen what the Color Data Table will look like when printed. Figure 42. Print Preview of Color Data Table 37 EasyMatch QC User’s Manual Version 3.8 • PRINT THIS VIEW: This command prints the Color Data Table view in a fashion like that shown below. Figure 43. Printed View of Color Data Table (Truncated page) • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. 2D Color Plot The 2D color plot displays a two-dimensional representation of color space with the standard as the center point of the plot and the samples plotted on the graph. In the example below, the a* of the L*a*b* scale is plotted on the x axis and the b* of L*a*b* is plotted on the y axis. Just to the right of this square portion of the plot is a thermometer graph that plots L*. The samples in the job are shown on the plot relative to the standard and each other. If tolerances have been set, the tolerance limits will be shown as a red box (for rectangular tolerances), ellipse (for elliptical tolerances), or pie segment (for polar tolerances) around the standard position. Placing the mouse over a point causes the sample ID, its pass or fail status, and its color values to be displayed. 38 EasyMatch QC User’s Manual Version 3.8 Figure 44. 2D Color Plot CLICK on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • SHOW BACKGROUND: This item, when checked, causes the colored background to be shown on the 2D Color Plot. When unchecked, the background is white. • SHOW LEGEND: This item, when checked, causes the legend (the list of which samples are currently displayed) to be shown to the left of the 2D Color Plot. When unchecked, the legend is not shown. • CONFIGURE: This command allows you to set various preferences pertaining to the 2D Color Plot view. Figure 45. 2D Color Plot Configuration Make your selections for each parameter, including the illuminant, observer, and color scale for display and the whether the hue circle and chroma line should be displayed. • PRINT PREVIEW: This command shows on-screen what the 2D Color Plot will look like when printed. 39 EasyMatch QC User’s Manual Version 3.8 Figure 46. Print Preview of 2D Color Plot • 40 PRINT THIS VIEW: This command prints the 2D Color Plot view in a fashion like that shown in the next figure. EasyMatch QC User’s Manual Version 3.8 Figure 47. Printed Output of 2D Color Plot • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. 41 EasyMatch QC User’s Manual Version 3.8 3D Color Plot The 3D color plot displays a three-dimensional representation of color space with the standard as the center point of the plot and the samples plotted on the graph. As shown in Figure 46, L*, a*, and b* are shown on the axes as labeled. The samples in the job are shown on the plot relative to the standard and each other. If tolerances have been set, the tolerance limits will be shown as a magenta box (for rectangular tolerances), ellipsoid (for elliptical tolerances), or ‘pie segment’ (for polar tolerances) around the standard position. Figure 48. 3D Color Plot CLICK on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • CONFIGURE: This command allows you to set various preferences pertaining to the 3D Color Plot view. Figure 49. 3D Color Plot Configuration Make your selections for each parameter, including the illuminant, observer, and color scale for display and whether you wish to display a flat representation of two fixed axes. You may also choose whether you wish to view a perspective projection (where data points that are 42 EasyMatch QC User’s Manual Version 3.8 further away from you are smaller than those that are closer) or an orthographic one (where all data points appear at the same scale), opt to turn on rotate mode, in which you may click on the plot and drag it to rotate it, and increase or decrease the opacity of the tolerance indicator. • PRINT PREVIEW: This command shows on-screen what the 3D Color Plot will look like when printed as shown in the next figure. Figure 50. Print Preview of 3D Color Plot • PRINT THIS VIEW: This command prints the 3D Color Plot view in a fashion like that shown in the next figure. Figure 51. Printer Output of 3D Color Plot 43 EasyMatch QC User’s Manual Version 3.8 • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 3D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. Color Render The Color Render view shows an accurate color rendering of items highlighted in the Job Tree view. This makes it easy to visually compare standards and samples even when the physical standards and samples are no longer available. By placing the mouse cursor over an area of the Color Render view, you may display a flag indicating the name of the item displayed and the illuminant/observer combination shown. Figure 52. Color Rendering Plot The following options are available by clicking the right mouse button within the boundaries of the view: • 44 CONFIGURE: Selection of CONFIGURE brings up the following dialog box, which allows you to set various preferences pertaining to the Color Render view: EasyMatch QC User’s Manual Version 3.8 Figure 53. Color Rendering Configuration Choose one, two, or three illuminant/observer combinations to render. If more than one combination is chosen, they are displayed side by side on the rendering display. • PRINT PREVIEW: This command shows you on-screen what the view will look like when printed as shown in the next figure. Figure 54. Color Rendering Print Preview • PRINT THIS VIEW: This command prints the Color Render view in a fashion like that shown in the next figure. 45 EasyMatch QC User’s Manual Version 3.8 Figure 55. Color Rendering Printer Output • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. EZ View The EZ View is a simple, eye-catching display of a limited amount of color data: up to four fields of color scale, difference, and/or index data, as well as pass/fail status if tolerances have been defined for the standard. 46 EasyMatch QC User’s Manual Version 3.8 Figure 56. Easy View Screen Click on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • CONFIGURE: This command allows you to set various preferences pertaining to the EZ View. Figure 57. EZ View Configuration Make one selection in the Illuminant/Observers box and then select either one color scale and one difference or index or a total of four differences and indices. The red number next to each parameter indicates how many more selections you have available. • PRINT PREVIEW: This command shows you on-screen what the view will look like when printed. The preview is shown in the next figure. 47 EasyMatch QC User’s Manual Version 3.8 Figure 58. EZ View Print Preview • PRINT THIS VIEW: This command prints the EZ View in a fashion like that shown in the next figure. Figure 59. EZ View Printer Output 48 • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. EasyMatch QC User’s Manual Version 3.8 • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. Memo View The Memo View is a blank view in which text, such as comments on the measurement method, may be entered using the keyboard and then stored in the job. An example of this view is shown below (Figure 58). Figure 60. Memo View CLICK anywhere in the white portion of the view and begin typing to enter your memo. Text does not wrap, so you will want to use the ENTER key at the end of each line to proceed to the next line. While this view is active, the following options are available by clicking the right mouse button: • CUT: Before using the CUT command, use the mouse to HIGHLIGHT THE TEXT you wish to remove from the Memo View. Then select CUT to permanently remove it from the view. If you wish, you may paste the text elsewhere, such as in a word processing program. • COPY: Before using the COPY command, use the mouse to HIGHLIGHT THE TEXT you wish to copy to the Windows clipboard. Then select COPY to copy it. If you wish, you may paste the text elsewhere, such as in a word processing program. • PASTE: Before you may use the PASTE command, you must have copied text to the Windows clipboard from another job or another program. Then, select PASTE to paste it into the Memo View. • SELECT ALL: This command allows you to highlight (select) all the text currently in the Memo View, such as selecting a font or copying. • DELETE: Before using the DELETE command, use the mouse to HIGHLIGHT THE TEXT you wish to remove from the Memo View. Then select DELETE to permanently remove it from the view. 49 EasyMatch QC User’s Manual Version 3.8 • FONT: Before using the FONT command, use the mouse to HIGHLIGHT THE TEXT for which you wish to modify the font. Then select FONT to obtain the following screen on which you may select the TEXT FONT, SIZE, and COLOR for the highlighted text. Figure 61. Memo View Configuration • PRINT PREVIEW: This command shows you on-screen what the view will look like when printed. Figure 62. Memo View Print Preview • 50 PRINT THIS VIEW: This command prints the Memo View in a similar fashion to that shown in the next figure. EasyMatch QC User’s Manual Version 3.8 Figure 63. Memo View Printer Output • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. Spectral Data Table The Spectral Data Table displays percent reflectance, percent transmittance, K/S, or absorbance values for each selected measurement at the wavelengths being measured. When reflectance, transmittance, or absorbance is being displayed, the cell representing the wavelength of minimum reflectance or transmittance (maximum absorbance) for each measurement is shaded pink. An example of this view is shown in the next figure. Figure 64. Spectral Data View 51 EasyMatch QC User’s Manual Version 3.8 CLICK on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • COPY TO CLIPBOARD: Before you initiate this command, you must HIGHLIGHT one or more of the samples and standards shown in the spreadsheet. When COPY TO CLIPBOARD is then selected, the highlighted data is then copied to the Windows Clipboard. If desired, the copied data may then be pasted into another application (such as Microsoft Excel) using its Paste command. • CONFIGURE: This command allows you to set various preferences pertaining to the Spectral Data Table view. Figure 65. Spectral Data Configuration Make your selections for each parameter, including the wavelength range and precision and whether you wish to view absolute or difference spectral data. (Difference is available only when the Spectral Data Type is Reflectance/Transmittance.) When Auto Size Cells is checked, the spreadsheet cells will be automatically sized based on the data contained in them. • PRINT PREVIEW: This command shows you on-screen what the view will look like when printed. Figure 66. Spectral Data Print Preview 52 EasyMatch QC User’s Manual Version 3.8 • PRINT THIS VIEW: This command prints the Spectral Data Table in a similar fashion to that shown below. Figure 67. Spectral Data Printer Output • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. 53 EasyMatch QC User’s Manual Version 3.8 Spectral Plot The Spectral Plot shows a plot of WAVELENGTH versus REFLECTANCE, TRANSMITTANCE, K/S, or ABSORBANCE for the entire scanning range of the spectrophotometer. The minimum and maximum values and their corresponding wavelengths are shown to the left of the plot. Figure 68. Spectral Plot View Click on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • SHOW BACKGROUND: This item, when checked, causes the colored background to be shown on the Spectral Plot. When unchecked, the background is white. • SHOW LEGEND: This item, when checked, causes the legend (the list of which samples are currently displayed) to be shown to the left of the Spectral Plot. When unchecked, the legend is not shown. • CONFIGURE: This command allows you to set various preferences pertaining to the Spectral Plot view. Make your selections for each parameter, including the wavelength and percent ranges. Figure 69. Spectral Plot Configuration • 54 PRINT PREVIEW: This command shows you on-screen what the view will look like printed. EasyMatch QC User’s Manual Version 3.8 Figure 70. Spectral Plot Print Preview • PRINT THIS VIEW: This command prints the Spectral Plot view in a similar fashion to that shown below. Figure 71. Spectral Plot Printer Output • CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. 55 EasyMatch QC User’s Manual Version 3.8 • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. Trend Plot The trend plot displays the trend of the data for each sample relative to the current standard. An example is shown in the next figure. Figure 72. Trend Plot View – Line and Point In this example, ‘Standard 1’ is the name of the standard. Four separate graphs are shown, each with three samples displayed. The top graph shows the change in lightness/darkness, or L*. The standard is plotted as the center line of this graph. Samples that are lighter than the standard are shown above this line in white, and samples that are darker are shown below the line in black. The L* value can be estimated based on the scale given to the left of the graph. Similarly, the second graph shows the change in redness/greenness, or a*. Samples in red above the standard line are redder than the standard and samples in green below the standard line are greener. Yellowness/blueness (b*) is shown on the third graph. dE* is shown at the bottom. CLICK on this view to make it active. While this view is active, the following options are available by clicking the right mouse button: • 56 CONFIGURE: This command allows you to set various preferences pertaining to the Trend Plot view. EasyMatch QC User’s Manual Version 3.8 Figure 73. Trend Plot Configuration Make your selections for each parameter, including the COLOR SCALE, FOURTH TRACE, and ILLUMINANT/OBSERVER combination. A line and point display is shown in the example at the beginning of this section. A column display graphs each data point as a rectangle above or below the standard line. Note: When Statistics are displayed in the Trend Plot, they are calculated based on the values of all the samples shown. The standard values are not included. • LIMITS: This command allows you to set parameters regarding the scale and limits of the trend plot. Figure 74. Trend Plot Limits Make your selections for each parameter. The range for each trace is the number of trace units that will be displayed around the standard for the trace. The control limit and warning limit are percentages of the tolerance for the trace or the number of standard deviations from the sample average where indicator lines will be shown (red for the control limit and purple for the warning limit). • PRINT PREVIEW: This command shows you on-screen what the view will look like when printed. 57 EasyMatch QC User’s Manual Version 3.8 Figure 75. Trend Plot Print Preview • PRINT THIS VIEW: This command prints the Trend Plot view in a fashion like that shown in the next figure. Figure 76. Trend Plot Printout • 58 CHANGE VIEW: This command allows you to replace the current view with another type of view (i.e., replace the 2D Color Plot with a Spectral Plot). EasyMatch QC User’s Manual Version 3.8 • DELETE VIEW: This command allows you to remove the current view from the job display. • SPLIT VIEW VERTICALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed side by side. • SPLIT VIEW HORIZONTALLY AND ADD: This command splits the current view into two and adds a new view so that the old view and the new view are displayed with one above the other. • MAXIMIZE THIS VIEW: This command causes the currently-selected view to be enlarged to the full size of the job. • RESTORE VIEW: This command restores the screen to its previous configuration after one view has been maximized. Database The database is a permanent repository of all spectral data and ID information for standards and samples that have been specifically saved to the database. When tolerances are assigned to standards, the tolerances can also be saved to the database with the standard. Data that has been saved to the database may be recalled in any job, but data that has been saved into a job has not necessarily been saved to the database. Use of the database is not required. Measurements may be permanently stored only in jobs if desired. The database is in a Microsoft Access (.MDB) or SQL Server format. See the File Menu chapter for information on saving data to the database and recalling data from the database and the Options Menu chapter for information on configuring the database type and location. Once the database is configured, its name is displayed on the EasyMatch QC title bar after the job name. Figure 77. Database Title Note: It is recommended that you back up your database, job, and template files periodically, particularly prior to upgrading or other major changes to your system computer. 59 EasyMatch QC User’s Manual Version 3.8 Keyboard Shortcuts Function keys have been assigned to some frequently used items and can be used to speed operation. New Job Ctrl + N Open Job Ctrl + O Recall Measurement from Database Ctrl + R Save Job Ctrl + S Save Job As Ctrl + A Save Job Template Ctrl + J Apply Template to Job Ctrl + T Save Measurement to Database Ctrl + M Print Job Ctrl + P Cut Ctrl + X Copy Ctrl + C Paste Ctrl + V Return to English Ctrl + E Delete Del Read Standard F2 Read Sample F3 Standardize F4 Read Series F5 Help Topics F1 Figure 78. Keyboard Shortcuts In addition, the EasyMatch QC menus may be opened using ALT + the first letter of the menu name and then the desired menu command may be selected by typing the underlined letter in the name of the command. These shortcuts are outlined below. 60 EasyMatch QC User’s Manual Version 3.8 Open File Menu Alt + F Open Edit Menu Alt + E Open View Menu Alt + V Open Measurements Menu Alt + M Open Options Menu Alt + O Open Sensor Menu Alt + S Open Window Menu Alt + W Open Help Menu Alt + H Figure 79. Open Commands Commands from an Open File Menu: New Job N Open Job O Open Job Template T Recall Measurement from Database R Delete Measurement from Database D Close Job C Save Job S Save Job As A Save Job Template J Save Job Template As B Save Measurement to Database M eSignature E Print Job Setup N Print Job Preview V Print Job P Printer Setup U Time Synchronization Y Database/Backup Database B Log Off L Open This Job 1-4 Exit X Figure 80. Command from Open File Menu 61 EasyMatch QC User’s Manual Version 3.8 Commands from an Open Edit Menu: Cut T Copy C Paste P Delete D Figure 81. Open Edit Menu Commands from an Open View Menu: Toolbar T Status Bar S Job Tree J Audit Log L Figure 82.Open View Menu Commands from an Open Measurements Menu: Read Standard S Read Sample R Average A Timed Read T Average Selected to Measurement U Average Selected to Standard N Average Selected to New Standard W Figure 83. Open Measurements Commands from an Open Options Menu: Naming Conventions N Average Method A Read Method R Configure Timed Read G Default Tolerances T Adjust Scale Factors L Application Preferences P Customize Toolbar Z Figure 84. Open Options 62 EasyMatch QC User’s Manual Version 3.8 Commands from an Open Sensor Menu: Install/Configure C Standardize S Set Modes M Import Logged Reads L Configure Setups P Configure Multi Mode C Figure 85. Open Sensor Commands from an Open Window Menu: New Window N Cascade C Tile T Bring this Job to the Front 1-4 Figure 86. Open Window Commands from an Open Help Menu: Help Topics H About A Figure 87. Open Help 63 EasyMatch QC User’s Manual Version 3.8 64 EasyMatch QC User’s Manual Version 3.8 The File Menu From the FILE MENU, you can open, save, and close jobs, as well as access the DATABASE, CONTROL THE PRINTER, E-MAIL JOBS, and EXIT EasyMatch QC. The functions available through the FILE MENU are described in the remainder of this chapter. File > New Job The FILE > NEW JOB command opens a new job based on the default template. This new job is presented on a new, untitled tab. The keyboard shortcut for this command is CTRL + N. File > Default Job FILE > DEFAULT JOB permits the user to define a default template and save it to the system. File > Open Job The FILE > OPEN JOB command allows you to open a pre-existing job that has been saved to your computer. The keyboard shortcut for this command is CTRL + O. Figure 88. Open Job Menu When the Select Job File dialog box appears, locate the job you wish to open from any drive or folder accessible by your computer. Highlight the job name and then click OPEN. The job is opened into EasyMatch QC. File > Open Job Template The FILE > OPEN JOB TEMPLATE command allows you to select a template to open and modify or use as the basis of a new job. 65 EasyMatch QC User’s Manual Version 3.8 Figure 89. Job Template: Open When the Open dialog box appears, LOCATE THE TEMPLATE you wish to open from any drive or folder accessible by your computer. HIGHLIGHT the template name and then click OPEN. The template is opened into EasyMatch QC. File > Recall Measurement from Database When you choose FILE > RECALL MEASUREMENT FROM DATABASE, a window appears where you must first choose whether you wish to RECALL, AUTO DB SEARCH, RECALL FROM COMMON DB. Recall RECALL A STANDARD, SAMPLE, or SERIES by choosing the appropriate radio button at the top right of the screen. On the left, you can ENTER THE ID, PRODUCT ID, AND/OR EXTRA ID FOR THE MEASUREMENT(S) to be recalled. You can also use (* and ?) wildcards to recall measurements. For example, to recall all measurements that start with ‘T’ you would enter ‘T*’ for the ID. Figure 90. Recall Measurement You can add information concerning the sensor, date and time, or other data parameters to your query. SELECT THE SENSOR TYPE and make sure that there is at least one standard or sample in the job. CLICK SEARCH if you wish to recall items based on their color difference from a standard or sample that is contained in the current job. The following screen appears. 66 EasyMatch QC User’s Manual Version 3.8 Figure 91. Recall Measurement based on dE Choose whether you wish to search based on differences from a standard or sample and then highlight the standard or sample for comparison in the white box. Then click OK. The Search Criteria screen appears. Figure 92. Search Criteria for dE Select the COLOR DIFFERENCE PARAMETER, ILLUMINANT, and OBSERVER you wish to use for the comparison and then ENTER THE MAXIMUM COLOR DIFFERENCE value from the selected sample or standard you wish to see. In the example shown in Figure 91, all standards within 2.00 dE* units using D65/10° from Sample 1 will be recalled. Click OK. You can save a set of search parameters as a query available for future use by typing in a QUERY ID and clicking SAVE. Later, select the QUERY ID from the drop-down box and click GET TO RECALL THE QUERY. After you have entered your selection parameters or recalled a query, click OK to display a list of the items in the database that match your recall parameters. You may sort this list, if you like, by clicking on the column header for the parameter by which you want to sort. 67 EasyMatch QC User’s Manual Version 3.8 Figure 93. Search Results SELECT (CHECK) THE ITEMS you wish to recall into the current job and click OK. They will be recalled and placed in the job. The keyboard shortcut for the RECALL MEASUREMENT FROM DATABASE command is CTRL + R. Auto DB Search Once the parameters are selected under recall, they can be saved as a query for Auto DB search. Figure 94. Search Using Query 68 EasyMatch QC User’s Manual Version 3.8 Figure 95. List of Queries Recall from Common DB This function is available only when Convergence CMR is enabled in EasyMatch QC. Convergence is an optional feature in EZMQC and Essentials. It allows users to save each measurement data from Essentials-based instruments into SQL database automatically through Essentials or EasyMatch QC, which could help users to organize data. Data in SQL database is more secured compared to be saved locally in instruments. Users could get the color data of all measurements through SQL database directly (No need to setup auto export). Users could take measurements through Essentials, recall these measurements in EZMQC from SQL database and then analysis data in EZMQC. Measurements will be showed in both Essentials and EZMQC simultaneously if both software is active. Convergence is available for Vista Essentials Rev 1.10 and above, Agera Essentials Rev 1.07 and above, and EZMQC 4.98 and above. Please note that Convergence is only working in English for Vista/Agera Essentials currently. For more details on this option, please refer to the Supplemental Manual for EasyMatch QC and Agera or Vista. File > Delete Measurement from Database When you choose FILE > DELETE MEASUREMENT FROM DATABASE, a window appears where you must first choose whether you wish to DELETE A STANDARD, SAMPLE, or SERIES by choosing the appropriate radio button at the top right of the screen. On the left, you can ENTER THE ID, PRODUCT ID, AND/OR EXTRA ID FOR THE MEASUREMENT(S) to be deleted. You can also use (* and ?) wildcards to recall measurements. For example, to delete all measurements that start with ‘T’ you would enter ‘T*’ for the ID. 69 EasyMatch QC User’s Manual Version 3.8 Figure 96. Delete from Database Click MORE if you wish to add information concerning the sensor, date and time, or other data parameters to your query. Figure 97. Criteria for Deletion Click SEARCH if you wish to delete items based on their color difference from a standard or sample that is contained in the current job. The following screen appears. Figure 98. Delete based on dE 70 EasyMatch QC User’s Manual Version 3.8 Choose whether you wish to search based on differences from a standard or sample and then highlight the standard or sample for comparison in the white box. Then click OK. The Search Criteria screen appears. Figure 99. Search Criteria for Deletion SELECT the COLOR DIFFERENCE PARAMETER, ILLUMINANT, and OBSERVER you wish to use for the comparison and then ENTER THE MAXIMUM COLOR DIFFERENCE VALUE from the selected sample or standard you wish to see. In the example shown above, all standards within 2.00 dE units using D65/10° from Sample 1 will be deleted. Click OK. You can SAVE A SET OF SEARCH PARAMETERS AS A QUERY available for future use by typing in a QUERY ID and clicking SAVE. Later, select the Query ID from the drop-down box and click GET to recall the query. After you have entered your selection parameters or recalled a query, click OK to display a list of the items in the database that match your delete parameters. You may sort this list by licking on the column header for the parameter to sort. Figure 100. Search Results for Deletion Select (check) the items you wish to DELETE FROM THE DATABASE and click OK. They will be deleted from the database File > Close Job The FILE > CLOSE JOB command saves the current job using its pre-established name and then closes the job. If the job is untitled, it prompts for a job name and then saves the job using its new name before closing the job. 71 EasyMatch QC User’s Manual Version 3.8 File > Save Job The FILE > SAVE JOB command saves the current job, including its measurements and screen configuration. If the job has been saved previously, it will automatically be saved under the same name. Otherwise, you will be prompted to enter a name. The keyboard shortcut for this command is Ctrl + S. File > Save Job As The FILE > SAVE JOB AS command allows you to save the current job under a new name or to name a previously untitled job. The complete job, including its measurements and screen configuration, is saved. The keyboard shortcut for this command is CTRL + A. Figure 101. File Save As When the SAVE JOB FILE AS dialog box appears, locate the drive and folder where you wish to save the job (any that are accessible by your computer). Type the desired job name into the File name box and then click SAVE. (Long file names and spaces are acceptable.) The job is saved. File > Save Job Template The FILE > SAVE JOB TEMPLATE command saves the screen configuration of the current job as a template. If the template has been saved previously, it will automatically be saved under the same name. Otherwise, you will be prompted to enter a name. The keyboard shortcut for this command is CTRL + J. File > Save Job Template As The FILE > SAVE JOB TEMPLATE AS command allows you to save the job template currently in use under a new name. Figure 102. Job Save As 72 EasyMatch QC User’s Manual Version 3.8 When the SAVE AS dialog box appears, locate the drive and folder where you wish to save the template (any that are accessible by your computer). Type the desired template name into the File name box and then click SAVE. (Long file names and spaces are acceptable.) The template is saved using the new name. File > Apply Template to Job The FILE > APPLY TEMPLATE TO JOB command allows you to apply a template to an existing job and have the configuration of that job change accordingly. The keyboard shortcut for this command is CTRL + T. File > Save Measurement to Database The FILE > SAVE MEASUREMENT TO DATABASE command saves any standards and samples currently selected (highlighted) in the Job Tree to the database. Once the measurement(s) are saved, the following message is shown. The keyboard shortcut for this command is CTRL + M. Figure 103. Measurements Saved File > e-Signature (-ER Version Only) The FILE > e-SIGNATURE command allows you to apply an electronic signature to the job. The following screen appears: Figure 104. eSignature Enter your EasyMatch QC USER NAME and PASSWORD, and type in the meaning of the signature or choose the meaning of the signature (creation, review, approval, etc.) from the drop-down box in the Comments box. These choices were configured by your System Administrator using the CFR Facile Admin tool (see the Validation and Compliance Notebook for more information). Click SIGN. After a moment, the signature is permanently applied to the job and can be viewed and printed by selecting VIEW > AUDIT LOG. File > Configure Company Logo The FILE > CONFIGURE COMPANY LOGO command allows you add a bitmap (.BMP) company logo or other graphic to printouts created using the FILE > PRINT JOB SETUP command. The following screen appears: 73 EasyMatch QC User’s Manual Version 3.8 Figure 105. Company Logo Configuration Click the BROWSE (...) button to find the file name and location for the logo file. The file can then be previewed on the Configure Company Logo screen. Figure 106. Select Company Logo Click OK. This logo will now be available as an item available for printing in print jobs. File > Header/Footer Setup The FILE > HEADER/FOOTER SETUP command allows you to configure the headers and footers that will be applied to all printouts in this job. Figure 107. Report Header & Footer 74 EasyMatch QC User’s Manual Version 3.8 You may type any information into the Header Information and Footer Information boxes that you wish to have displayed on every page of your printouts. Type any of the codes listed at the bottom of the screen to have that information automatically inserted. For example, type ‘%t’ to have the time of printing shown on the printout. File > Print Job Setup The FILE > PRINT JOB SETUP command allows you to lay out a report that will be printed when you select FILE > PRINT JOB or click the PRINT button on the default toolbar. All data views currently in your job except the Job Tree may be printed as part of your report. When you print the report, data for all the samples and standards currently selected in your Job Tree for display in the other views will be printed. When PRINT JOB SETUP is selected, the Print Job Setup screen is obtained. The printer and paper size as designated for your Windows default printer will be shown at the top of the screen and all data views in the current job are shown under Available Items. The header and footer configured in HEADER/FOOTER SETUP and company logo configured in CONFIGURE COMPANY LOGO (discussed earlier in this chapter) may also be placed in the report. Figure 108. Print Job Setup To add an item to your report, highlight it in the AVAILABLE ITEMS list on the right side of the display by clicking on its name and then click the <<ADD button. The item is moved to the Selected Items box and is assigned a representative color. You may remove an item added in error by highlighting it in the Selected Items list and using the REMOVE>> button. To configure the size and location of an item on the page, highlight it in the SELECTED ITEMS LIST on the left side of the screen. Then CLICK the mouse on the page representation in the middle of the screen where you wish to locate one of the corners of the view. HOLD THE MOUSE BUTTON AND DRAG TO THE LOCATION of the opposite corner. Then release the mouse button. The colored box indicates the location and size of that data view. It may be altered at any time using the same procedure. 75 EasyMatch QC User’s Manual Version 3.8 Figure 109. Selected Views to Print You may click the ADD PAGE button to add a new page to your report and scroll through the pages of your report using the PREV PAGE and NEXT PAGE buttons. When a Spectral Data Table has been added to the Selected Items box and is highlighted, a CONFIGURE button appears next to the REMOVE>> button. When the CONFIGURE button is clicked, the Configure Spectral Data screen appears on which you can alter the WAVELENGTH RANGE and INTERVAL that will be shown in this part of the screen. You may include multiple Spectral Data Tables with different wavelength ranges if you wish to fit all the data in the print job. Figure 110. Printing Spectral Data Table File > Print Job Preview The FILE > PRINT JOB PREVIEW command allows you to view your configured print job on-screen as it will appear when printed. If you select this command without having configured the print out using the PRINT JOB SETUP command, you will be prompted to do so. 76 EasyMatch QC User’s Manual Version 3.8 Figure 111. Print Job Preview File > Print Job The FILE > PRINT JOB command initiates printing of the print job that was configured using the PRINT OUT SETUP command. The job is printed to the Windows default printer. The keyboard shortcut for this command is CTRL + P. If you select this command without having configured the print out using the PRINT OUT SETUP command, you will be prompted to do so. File > Printer Setup The FILE > PRINTER SETUP command causes the Windows Print Setup dialog box to be displayed so you can configure your printer parameters without printing anything. Click OK when your configuration is complete. The configuration indicated here is used for all printing in EasyMatch QC, regardless of job. Figure 112. Printer Setup 77 EasyMatch QC User’s Manual Version 3.8 File > Page Setup The File > Page Setup command opens the Page Setup window in which you can set the margins you wish to leave on each page when printing the print job configured using the PRINT JOB SETUP command described earlier in this chapter. Click OK when your configuration is complete. Figure 113. Printer Margins File > Import QTX Format The FILE > IMPORT QTX FORMAT command opens the Windows Open box that allows you to choose an existing QTX file for import into the current EasyMatch QC job. Once you click OPEN, the data records in the QTX file will be added to the current job. Figure 114. Import File into Current Job Note: A sensor of the same type (i.e., UltraScan PRO) as the one used in making the measurements contained in the QTX file must be the current active sensor in EasyMatch QC for the QTX file to import. File > Export The FILE > EXPORT command allows you to export job data to either the QTX format . A submenu appears from which you can make this selection. QTX Format Select QTX FORMAT to export the data in the job to a QTX color communication file that, when opened in Windows Notepad, resembles the following: 78 EasyMatch QC User’s Manual Version 3.8 Figure 115. QTX Format File > Email The FILE > EMAIL command, and then the choice of JOB or TEMPLATE from the submenu that appears opens a new e-mail message and attaches the current job or template to that message. This command appears in the FILE menu only if an e-mail program is installed and available on your computer. The picture below uses Microsoft Outlook 98. Compose and send your e-mail as you normally would be using your e-mail program. Figure 116. Email Command 79 EasyMatch QC User’s Manual Version 3.8 Note: If Job is chosen from the submenu, the job is e-mailed with its screen configuration (template) intact. If Template is chosen, only the template is e-mailed. File > Time Synchronization (-ER Version Only) The FILE > TIME SYNCHRONIZATION command causes your client computer’s clock to be synchronized with the server computer. Your system administrator should check the time and date on the server periodically to ensure that it is correct. File > Database The FILE > DATABASE command allows you to manually back up your Access database file, import data stored in a Universal Software or EasyMatch Textiles database into EasyMatch QC, or create a new Access database. A submenu appears containing these four choices. Backup Database Select BACKUP DATABASE to save a second copy of your EasyMatch QC Access database file to a location other than the one where it is currently stored. The following screen appears. Figure 117. Database Backup Browse for the location where you wish the backup copy of the database to be stored and then click SAVE. The file will be copied to this location. Universal Database Import Select UNIVERSAL DATABASE IMPORT to import measurements from a Universal Software database. Universal Software must be installed on this computer to complete the import, as the Universal installation provides necessary information to the import tool. Figure 118. Database Import 80 EasyMatch QC User’s Manual Version 3.8 The import tool automatically looks for a database in the C:\Universe\DB folder on your hard drive. If this is the database you wish to import, you need not use the SET UNIVERSAL SW FOLDER or SET DATABASE FOLDER buttons. If, on the other hand, your Universal Software was installed into a folder other than C:\Universe, click the SET UNIVERSAL SW FOLDER button and select the folder where Universal Software was installed. If the Universal database you wish to import is in a folder other than C:\Universe\DB, click the SET DATABASE FOLDER button and select the folder where the database is located. When both folders have been indicated correctly, the sensor(s) with which the database measurements were made will be shown in the upper right corner of the screen and a list of samples and standards stored in the database will be shown below. To examine the details (date and time of reading, plus spectral data) of any sample or standard, highlight it and click the SHOW DETAILS button. Figure 119. Import Measurement Select all the records you wish to import into EasyMatch QC using the CTRL key plus clicking on each individual record, by holding the SHIFT key and clicking on the first and then the last record desired, or by clicking the SELECT All button. Then click IMPORT DATABASE. You will be given the choice to place the records in your EasyMatch QC database, in your current job, or in a new job. When you click OK, the records will be imported to the location you chose. Figure 120. Import Dialog Box Figure 121. Import Completed Create New Database Select CREATE New Database to create a new, empty Access database with the name and location desired. This new database will not be used for storing measurements until you select it using OPTIONS > SYSTEM CONFIGURATION > DATA STORAGE. 81 EasyMatch QC User’s Manual Version 3.8 Figure 122. Save New Database Import Textiles Database Select IMPORT TEXTILES DATABASE to import measurements from an EasyMatch Textiles database. The following screen appears first. Note: Select Textiles Database must be checked with a Textiles Database Path set in Options >System Configuration > Data Storage before the File > Import Textiles Database command will be available. Figure 123. Import Database Indicate whether you wish to import the standards that are in the database or the samples, then click OK. Figure 124. Results of Searching a Database The samples or standards available in the EasyMatch Textiles database are listed and you may select the ones you wish to import. Then click OK. 82 EasyMatch QC User’s Manual Version 3.8 Figure 125. Import File to . . . Indicate whether you wish to import the EasyMatch Textiles measurements into the current EasyMatch QC job or the EasyMatch QC database. Then click OK. The measurements will be imported as you instructed. If you imported sample(s) to a job, you will be asked to link the sample(s) to a standard before they are inserted into the job. File > Log Off The FILE > LOG OFF command logs the current user out of EasyMatch QC and returns to the EasyMatch QC splash screen so that the next user may log on. If the current job has not yet been saved, you will be prompted to save it before log off occurs. Figure 126. Log Off for User Note: This command is available only if Login Required is checked on the Startup Defaults tab available by choosing Options > Application Preferences. File > Most Recently Opened Jobs The most recently opened jobs area of the FILE MENU lists the four most recently opened jobs. You may select the name of any of these jobs to open it quickly and easily. File > Exit The FILE > EXIT command allows you exit EasyMatch QC. If the current job has not yet been saved, you will be prompted to save it before exit occurs. 83 EasyMatch QC User’s Manual Version 3.8 84 EasyMatch QC User’s Manual Version 3.8 The Edit Menu From the EDIT MENU, you can cut or copy the samples and standards highlighted in the Job Tree to the Windows clipboard for use in another job. Likewise, you can paste measurements from another job into this one. You may also delete measurements. The functions available through this menu are described in the remainder of this chapter. Edit > Cut The EDIT > CUT command allows the measurement(s) highlighted in the Job Tree to be removed and placed on the Windows clipboard. The measurements can then be pasted into another job. The keyboard shortcut for this command is CTRL + X. Note: If you cut measurement(s) and then don’t paste them elsewhere, they will be permanently deleted. Edit > Copy The EDIT > COPY command allows the measurement(s) highlighted in the Job Tree to be copied to the Windows clipboard. The measurement(s) can then be pasted into another job. The keyboard shortcut for this command is CTRL + C. Items may also be dragged and dropped from one job to another to copy and then paste them. Edit > Paste The EDIT > PASTE command allows you to paste measurement(s) from one job into another. Before you select PASTE, select the job in which you would like the measurement to be placed and click in the Job Tree (in a blank area if you cut or copied a standard or on the desired ‘Samples’ branch header for a sample). Then, when you select PASTE, the measurement(s) from the clipboard are placed in that job. The keyboard shortcut for this command is CTRL + V. Items may also be dragged and dropped from one job to another to copy and then paste them. Edit > Delete The EDIT > DELETE command deletes the measurement(s) that are highlighted in the Job Tree from the current job. You are prompted to confirm that you wish to delete. Figure 127. Confirming Deletion The keyboard shortcut for this command is DEL. 85 EasyMatch QC User’s Manual Version 3.8 86 EasyMatch QC User’s Manual Version 3.8 The View Menu The VIEW menu allows you to turn on or off display of the toolbar, status bar, and Job Tree on your EasyMatch QC screen. The functions available through this menu are described in the remainder of this chapter. View > Toolbar The VIEW > TOOLBAR command allows you to choose whether to display the toolbar beneath the menu bar at the top of your EasyMatch QC screen. When a check appears next to TOOLBAR, the toolbar is displayed. When no check appears, the toolbar is not displayed. The setting chosen here applies to this installation of EasyMatch QC regardless what job is in use. Figure 128. Display of Toolbar Figure 129. Toolbar Not Displayed 87 EasyMatch QC User’s Manual Version 3.8 View > Status Bar The VIEW > STATUS BAR command allows you to choose whether to display the status bar at the bottom of your EasyMatch QC screen. When a check appears next to STATUS BAR, the bar is displayed. When no check appears, the status bar is not displayed. The setting chosen here applies to this installation of EasyMatch QC regardless what job is in use. Figure 130. Status Bar is Displayed Figure 131. No Status Bar Displayed 88 EasyMatch QC User’s Manual Version 3.8 View > Job Tree The VIEW > JOB TREE command allows you to choose whether to display the Job Tree at the left of your EasyMatch QC screen for the current job. When a check appears next to JOB TREE, the Job Tree is displayed. When no check appears, the Job Tree is not displayed. Note: Some software functions require use of the Job Tree. Figure 132. Job Tree is Displayed Figure 133. Job Tree Not Displayed View > Audit Log (-ER Version Only) The VIEW > AUDIT LOG command allows you to view the audit log for the current job. Select the types of events you would like to view from the drop-down box next to FILTER BY. The available choices are Save (the job), Edit, 89 EasyMatch QC User’s Manual Version 3.8 Print (the job or a view), Signature, and All. Click PRINT AUDIT LOG to print the log to the Windows default printer in a fashion like that shown at the bottom of this page. Figure 134. View Audit Log Figure 135. Printout of Audit Log View > Event Log (-ER Version Only) The VIEW > EVENT LOG is a log of events taken by a user within the EasyMatch QC-ER application that are generally steps outside a Job with codes for the different application operations. If a client selects the item + code; then selects DETAILS at the bottom of the screen, the full details for the Event Log item are listed. 90 EasyMatch QC User’s Manual Version 3.8 Figure 136. Event Log Filters Figure 137. Event Log Configuration Figure 138. Event List 91 EasyMatch QC User’s Manual Version 3.8 Figure 139. Event Details 92 EasyMatch QC User’s Manual Version 3.8 The Measurements Menu From the MEASUREMENTS MENU, you may read either a standard or a sample. You may also average data. The functions available through the MEASUREMENTS MENU are described in the remainder of this chapter. Measurements > Read Standard The MEASUREMENTS > READ STANDARD command initiates reading of a standard. Place the standard before initiating the READ STANDARD command. If Prompt for standard name was checked in OPTIONS > NAMING CONVENTIONS, you will then be prompted to enter a name for the standard (as well as a Product ID and Extra ID, if you wish). You may simply accept the name defined using the NAMING CONVENTIONS command, if desired. The measurement is then accepted and added to the current job. The keyboard shortcut for this command is F2. Figure 140. Enter Standard ID Measurements > Read Sample The MEASUREMENTS > READ SAMPLE command initiates reading of a sample. Place the sample before initiating the READ SAMPLE command. If Prompt for sample name was checked in OPTIONS > NAMING CONVENTIONS, you will then be prompted to ENTER A NAME for the sample (as well as a Product ID and Extra ID, if you wish) and to choose the standard with which the sample should be linked. (‘Standard Empty’ is a choice if you do not want to link to a standard.) You may simply accept the name defined using the NAMING CONVENTIONS command and the suggested standard, if desired. The measurement is then accepted and added to the current job. The keyboard shortcut for this command is F3. Figure 141. Enter Sample ID 93 EasyMatch QC User’s Manual Version 3.8 Measurements > Read Series The MEASUREMENTS > READ SERIES command creates a new standard in the current job. This standard has no color values (i.e., L=0, a=0, b=0), but can be used to indicate a tolerance box of color values within which samples must fall to be considered ‘in-spec.’ Once the standard is created, select it (and only it) in the Job Tree. Then, RIGHT-CLICK on the standard and choose PROPERTIES. Click the TOLERANCES button to obtain a Tolerances screen on which you can enter the tolerance box desired by entering the minimum (min) and maximum (max) acceptable values for each parameter of the color scale. Samples that are read and assigned to this standard will then be compared to this tolerance box. The keyboard shortcut for this command is F5. Y, x, y Chromaticity Plot for Highway Safety Colors (ASTM 4956) The Measurement Series allows input for Chromaticity tolerances and a display of a Y scale plot and a trapezoid plot to accommodate the PASS/FAIL tolerances for Highway/Safety Colors. To use this function for this application following the instructions below: 1. Go to MEASUREMENTS > READ SERIES and NAME the Series. Press OK to continue. Figure 142. Name the Series 2. Enable the COLOR DATA TABLE and RIGHT-CLICK to CONFIGURE. Select the scale as Yxy, the illuminant and select TOLERANCES by clicking on the box. 94 EasyMatch QC User’s Manual Version 3.8 Figure 143. Configure Color Data Table 3. READ STANDARD and from the JOB TREE >RIGHT CLICK on the circle next to the standard in the Job Tree. Select PROPERTIES. Figure 144. Right Click to Select Standard Properties 4. Click on TOLERANCES and then change the selected scale to Yxy and Ill/Obs. Enter the desired tolerances. 95 EasyMatch QC User’s Manual Version 3.8 Figure 145. Select Tolerances Figure 146. Input Tolerance Limits 5. Return to the Main Measurement Screen. In the lower part of the screen, select to view the 2D COLOR PLOT and configure the scale to Yxy. Figure 147. Configure Color Plot 6. All samples measured in this series will have these tolerances applied. Return to the Measurement Screen to view the Color Data table, the PASS/FAIL values and the 2D Color Plot. 96 EasyMatch QC User’s Manual Version 3.8 Figure 148. Graphical Display of Chromaticity Plot Measurements > Average The MEASUREMENTS > AVERAGE command, when checked, initiates on reading the OPTIONS > AVERAGE METHOD selected. After the first reading is taken, the following screen appears. Figure 149. Measurement Average Click READ to initiate each additional reading in the set of readings and AVERAGE to complete the average and add the averaged measurement to the job. You may also delete individual readings in the set by highlighting them and clicking DELETE 97 EasyMatch QC User’s Manual Version 3.8 Figure 150. Calculating Measurement Average The setting chosen here applies to the current job only. Measurements > Timed Read The MEASUREMENTS > TIMED READ command, when checked, initiates on reading the timed read method selected using the OPTIONS > CONFIGURE TIMED READ command. When READ SAMPLE is chosen, measurements are made at the interval chosen until the number of measurements indicated have been made or until the READ SAMPLE button on the toolbar is clicked. The setting chosen here applies to the current job only. Measurements > Automatic Standard Search The MEASUREMENTS > AUTOMATIC STANDARD SEARCH command, when checked, initiates the automatic standard search function as configured using the OPTIONS > CONFIGURE AUTOMATIC STANDARD SEARCH command. When AUTOMATIC STANDARD SEARCH is chosen and measurement of a sample is initiated, either the one standard contained in the database that is closest to that read sample is automatically recalled into the job and linked to the sample, or the closest five standards are offered for selection. The setting chosen here applies to the current job only. Figure 151. Search Results for Best Standard Fit 98 EasyMatch QC User’s Manual Version 3.8 Measurements > Average Selected to Measurement The MEASUREMENTS > AVERAGE SELECTED TO MEASUREMENT command creates a new sample that is the arithmetic average of all the measurements currently highlighted in the Job Tree. You are prompted to choose the standard to which this new sample will be linked and allowed to name the sample. Figure 152. Standard to Compare Average Figure 153. Calculated Measurement Average If spectral reflectance or transmittance data is available for all the measurements being averaged, this spectral data will be averaged in creating the new sample. If spectral reflectance or transmittance data is not available for any or all the measurements being averaged, CIE XYZ data will be averaged in creating the new sample. Measurements > Average Selected to Standard The MEASUREMENTS > AVERAGE SELECTED TO STANDARD command averages the items that are currently selected (highlighted) in the Job Tree and replaces the current standard on the branch with the averaged measurement, while retaining the current standard name. If spectral reflectance or transmittance data is available for all the measurements being averaged, this spectral data will be averaged in creating the standard. If spectral reflectance or transmittance data is not available for any or all the measurements being averaged, CIE XYZ data will be averaged in creating the standard. Measurements > Average Selected to New Standard The MEASUREMENTS > AVERAGE SELECTED TO NEW STANDARD command averages the items currently selected (highlighted) in the Job Tree and creates a new standard for the averaged measurement, which you are prompted to name. Figure 154. Measurement Average Saved as Standard If spectral reflectance or transmittance data is available for all the measurements being averaged, this spectral data will be averaged in creating the new standard. If spectral reflectance or transmittance data is not available for any or all the measurements being averaged, CIE XYZ data will be averaged in creating the new standard. 99 EasyMatch QC User’s Manual Version 3.8 100 EasyMatch QC User’s Manual Version 3.8 The Options Menu From the OPTIONS MENU, you can set various preferences concerning your use of the software, such as your naming conventions and default tolerances. The functions available through the OPTIONS MENU are described in the remainder of this chapter. Options > Naming Conventions The OPTIONS > NAMING CONVENTIONS command allows you to establish naming conventions that will be used when standards and samples are read in all jobs by default (when GLOBAL is chosen from the submenu) or in the current job (when JOB is chosen from the submenu). There are five tabs available on the Naming Conventions screen: SAMPLE, STANDARD, SERIES, PRODUCT ID and EXTRA ID. The SAMPLE tab allows you to set the default naming convention for your samples. You may type any desired text into the Sample ID String Layout box. You may also insert a number to be automatically incremented with each sample read, and/or insert the date and time the sample is read to be automatically applied to the sample. You may override the default name by typing a new one into the box that appears when reading is initiated. This requires a check box next to the PROMPT FOR SAMPLE NAME. If this box is unchecked, the naming convention will be used automatically without allowing you to override it. Figure 155. Setting Up Naming Rules The STANDARD tab allows you to set the default naming convention for your standards. You may type any desired text into the Standard ID String Layout box. You may also insert a number to be automatically incremented with each standard read, and/or insert the date and time the standard is read to be automatically applied to the standard. You may override the default name by typing a new one into the box that appears when reading is initiated if the PROMPT FOR STANDARD NAME box is checked. If this box is unchecked, the naming convention will be used automatically without allowing you to override it. 101 EasyMatch QC User’s Manual Version 3.8 Figure 156. Rules for Naming Standards The SERIES ID tab allows you to set the default naming conventions for your data series. You may type any desired text into the Series ID String Layout box. You may also insert a number to be automatically incremented with each series created, and/or insert the date and time the series is created to be automatically applied to the series. You may override the default name by typing a new one into the box that appears when reading is initiated if the PROMPT FOR SERIES NAME box is checked. If this box is unchecked, the naming convention will be used automatically without allowing you to override it. Figure 157. Rules for Naming Series The PRODUCT ID tab allows you to set the default product IDs for your standards and samples. A list of Product IDs may be maintained and chosen on this tab. Type text for a new Product ID into the box and then click ADD SELECTION to add it to the list. Choose an ID to be deleted from the drop-down box and click REMOVE SELECTION to remove it from the list. The ID that is currently selected from the drop-down box is the one that will be automatically applied on reading. 102 EasyMatch QC User’s Manual Version 3.8 Figure 158. Rules for Naming Products At the bottom of the screen, you may choose to limit your Standard and Sample Product IDs to only those that already exist, to the current selection in the drop-down box, or neither. The EXTRA ID tab allows you to set the default extra IDs for your standards and samples. A list of Extra IDs may be maintained and chosen on this tab. Type text for a new Extra ID into the box and then click ADD SELECTION to add it to the list. Choose an ID to be deleted from the drop-down box and click REMOVE SELECTION to remove it from the list. The ID that is currently selected from the drop-down box is the one that will be automatically applied on reading. Figure 159. Extra ID Rules At the bottom of the screen, you may choose to limit your Standard Extra IDs to only those that already exist, to the current selection in the drop-down box, or neither. You may choose to limit your Sample Extra IDs to those that already exist, to the current selection in the drop-down box, to the Standard Extra ID, or none of these options. Options > Average Method The OPTIONS > AVERAGE METHOD command allows you to indicate the method by which you wish to average when standard and sample measurements are made in the current job. 103 EasyMatch QC User’s Manual Version 3.8 Figure 160. Selecting a Method for Averaging The DISPLAY METHOD controls the information shown in the averaging window while you are taking measurements. For Display Method, you can select NONE, SCALE, INDEX, or SPECTRAL. For Scale or Index, you must also choose the SCALE OR INDEX, ILLUMINANT, and OBSERVER that will appear in the averaging window while you are taking readings. Note: The Average box will display color values based on the parameters set using the Average Method command. These color values will not match those shown in the Color Data Table unless the scale, illuminant, and observer match for the average method and the Color Data Table. In the Average Method area, you may select CONTINUOUS or N OF N. If you select CONTINUOUS, then you can monitor the running average of the measurements each time you choose to read and terminate the readings (by clicking AVERAGE) when the running average stabilizes. If you select N OF N, then you can average a specified number of readings for each measurement. Check the box next to USE SAMPLE PRESENTATION PROMPTS if you wish to enter a helpful prompt to be shown before each reading to guide your users through the averaging sequence. Once the box is checked, ENTER THE PROMPT FOR THE FIRST READING into the white box. Click the RIGHT ARROW (>>) button and enter each successive prompt until the last reading in the sequence is reached. Check SHOW PROMPTS when measuring standards if you wish your prompts to be shown when measuring standards, in addition to when measuring samples. Note: If the timed read feature is also being used, its timing will be ignored to give you a chance to follow the prompts before each reading. Options > Read Method When you select OPTIONS > READ METHOD you can choose a special read method for the sensor in use. These are types of measurements that require more than one reading to obtain a result. If you select NORMAL, then the measurement is either a single reading or an average of multiple readings. 104 EasyMatch QC User’s Manual Version 3.8 Figure 161. Selecting Special Read Method After standardizing in reflectance, if you select OPACITY, you will perform two readings -- one with the sample backed by white and one with the sample backed by black. In the OPACITY SELECTIONS area, you may choose to display Y WHITE and/or Y BLACK in your Color Data Table view in addition to OPACITY by checking the desired boxes. Also, choose the ILLUMINANT/OBSERVER combination for which you would like to display opacity. If DIFFERENCE values are required, check the box at the bottom, then press OK to continue. Figure 162. Read Method Menu: Opacity After standardizing in transmittance, if you select HAZE you will perform two readings -- one with the instrument white tile at the reflectance port and one with the light trap at the port. In the Haze Selections area, you may choose to display Y TOTAL and/or Y DIFFUSE in your Color Data Table view in addition to Haze by 105 EasyMatch QC User’s Manual Version 3.8 checking the desired boxes. Also, choose the ILLUMINANT/OBSERVER combination for which you would like to display Haze. Figure 163. Read Method Menu: Haze Note: Haze is available only with the Vista, UltraScan PRO, and UltraScan VIS sensors. If you select MULTIPLE READ MODE, two readings are made and displayed each time measurement is initiated, one in each of the two standardization modes chosen using the SENSOR > CONFIGURE MULTI MODE command. Figure 164. Multimode Read Option Note: Multiple Read Mode is available only with the Agera, LabScan XE, UltraScan PRO, and UltraScan VIS sensors. The averaging feature activated by clicking Average in the Measurements menu cannot be used in conjunction with multimode reading. You can average selected readings that result from the multimode reading after the readings are completed by using the Average Selected to command in the Measurements menu. Options > Configure Timed Read The OPTIONS > CONFIGURE TIMED READ command allows you to select how you wish EasyMatch QC to automatically perform sample readings within the current job at a specified time interval. 106 EasyMatch QC User’s Manual Version 3.8 Figure 165. Timed Readings Select the Read Count Method desired. You may choose either Continuous Readings or a Fixed Number of readings between 1 and 1000. Also, select the Read Interval (time between the end of one reading and the beginning of the next reading) desired. You may choose from 4 to 60 seconds. Click on OK to accept the parameters. Note: Also select (check) Timed Read in the Measurements menu to activate the timed readings you configured here. Options > Configure Automatic Standard Search The OPTIONS > CONFIGURE AUTOMATIC STANDARD SEARCH command allows you to specify how you would like automatic standard searching to be performed in the current job. This feature is initiated when you read a sample, at which time the sample is compared to all standards currently saved in the database. The standard that is closest in color to the sample is recalled into the current job and linked to the read sample. Figure 166. Automatic Standard Search SELECT THE PARAMETER for which the sample-standard comparison will be performed. Your choices are dE, dE CMC, and dE*. Also, select the ILLUMINANT/OBSERVER combination under which the comparison will be performed and whether you wish to AUTOMATICALLY RECALL THE CLOSEST STANDARD to the sample or CHOOSE FROM A LIST OF THE CLOSEST FIVE STANDARDS. Click OK to accept the parameters. Note: Also select (check) Automatic Standard Search in the Measurements menu to activate the automatic standard searching you configured here. Options > Default Tolerances The OPTIONS > DEFAULT TOLERANCES command allows you to set the tolerances that will be assigned to new standards in the current job by default. You may set tolerances for as many scales, indices, and differences for as many illuminant/observer combinations as you wish. You may override the default tolerances after a standard is read by choosing PROPERTIES from the menu that appears when RIGHT-CLICKING ON THE STANDARD IN THE JOB TREE. 107 EasyMatch QC User’s Manual Version 3.8 Figure 167. Setting Tolerances On the SCALES tab, set all tolerances you wish to assign based on color scales. Choose the color scale from the SELECTED SCALE drop-down box and the ILLUMINANT/OBSERVER combination from the Illuminant/Observer drop-down box. Then enter the UPPER AND LOWER TOLERANCE LIMITS (the allowable differences from the standard values) for each of the three components of the color scale for this illuminant/observer combination. Then enter tolerances for all other scales and illuminant/observer combinations desired by choosing each one individually and typing the tolerance values. It is not necessary to click OK after entering each set of tolerances. Clicking OK once will cause all tolerances entered to be accepted. Figure 168. Setting Tolerances for an Index On the INDICES tab, set all tolerances you wish to assign based on indices. Choose the index from the Selected Index drop-down box and the ILLUMINANT/OBSERVER combination from the Illuminant/Observer drop-down box. Then enter the upper and lower tolerance limits (the allowable difference from the standard value) for the index for this illuminant/observer combination. Then enter tolerances for all other indices and illuminant/observer combinations desired by choosing each one individually and typing the tolerance values. It is not necessary to click OK after entering each set of tolerances. Clicking OK once will cause all tolerances entered to be accepted. 108 EasyMatch QC User’s Manual Version 3.8 Figure 169. Setting Tolerances for a Difference On the DIFFERENCES tab, set all tolerances you wish to assign based on color differences. Choose the difference from the SELECTED DIFFERENCE drop-down box and the illuminant/observer combination from the ILLUMINANT/OBSERVER drop-down box. Then enter the UPPER AND LOWER TOLERANCE LIMITS for the difference for this illuminant/observer combination. Then enter tolerances for all other differences and illuminant/observer combinations desired by choosing each one individually and typing the tolerance values. It is not necessary to click OK after entering each set of tolerances. Clicking OK once will cause all tolerances entered to be accepted. Note: EasyMatch QC pre-sets dE CMC to 1. If you are using your own tolerances, change dE CMC to zero to turn it off. Figure 170. Setting Shade Tolerances On the SHADE tab, ENTER THE TOLERANCE you wish to use for the first, second, and third traces, which will be the three parameters of your color scale (i.e., L*a*b*, L*C*h). Also, SELECT THE NUMBER OF SHADE BLOCKS to be contained within your pass/fail tolerance. For instance, if you choose 5, the blocks within your tolerance will be 3, 4, 5, 6, and 7. In the example shown in Figure 147, the pass/fail tolerance is 0.2 for each color scale parameter, and 5 shade blocks will fit within that tolerance value. 109 EasyMatch QC User’s Manual Version 3.8 Figure 171. Setting Haze & Opacity Tolerances On the HAZE and OPACITY tab, ENTER THE TOLERANCES you wish to use for the haze and opacity read methods. Click OK to accept the default tolerances and close the Tolerances screen. Options > Adjust Scale Factors The OPTIONS > ADJUST SCALE FACTORS command allows you to set various factors used in the calculations for dE CMC, dE CIE94, DIN99, and dE* 2000 differences, plus the ASTM D1500-33mm, Saybolt-50/100mm index, LOVIBOND® and AOCS RY when using Agera, UltraScan PRO, UltraScan VIS or Vista. These factors apply to all jobs used in this installation of EasyMatch QC. Figure 172. Select Adjustable Scale When the Select Adjustable Scale screen appears, first choose the scale of interest from the drop-down box. Then, click OK. The screen where the desired factors may be entered appears. Note: LOVIBOND is a trademark of Tintometer LTD, UK. 110 EasyMatch QC User’s Manual Version 3.8 Figure 173. Enter CMC Factors ENTER THE FACTORS desired or click the DEFAULT VALUES button to return the factors to their default values. Click OK to begin using the new factors. Options > ASCII Export The OPTIONS > ASCII EXPORT command opens a submenu with two commands: EXPORT DATA and CONFIGURE. The EXPORT DATA option initiates export of the readings that are currently highlighted in the Job Tree in the format that was chosen using the CONFIGURE command, described below. You are first prompted for the output file name, and then the data is sent to the file when you click OK. Figure 174. Export ASCII The CONFIGURE option allows you to choose the parameters you would like to export when EXPORT DATA is selected. The screen below is obtained. Figure 175. ASCII Export Configuration 111 EasyMatch QC User’s Manual Version 3.8 Configure the spectral data in the OTHER > ASCII EXPORT > CONFIGURATION dialog if they need the spectral data in 10 or 20nm increments. Color indices, color indices, text fields, and procedures are exported if they are displayed in Color Data Table view. The information currently selected for export is displayed on the left side of this window, and all available parameters are listed on the right side of the window. Configure the spectral data and the data format on the right side of the window and then click on the LEFT ARROW (<<) button nearest to the item to move the item into the SELECTED ITEMS list. Highlight each item to delete on the left side of the window and click the RIGHT ARROW (>>) button to remove it from the list. Select to AUTOMATICALLY EXPORT NEW DATA by checking the box. Also, enter (or browse for) the directory and name for the export file in the box below and select AUTO EXPORT USES THIS FILE. The file extension .CSV will automatically be appended if you chose to export to a comma-delimited file. TXT will be appended for all other types of files. Long file names with spaces and network paths are all acceptable for use. Click OK when all selections have been made. A sample output is shown below. Figure 176. ASCII Export to Notepad Each job may have its own ASCII export configuration. Multiple jobs may export to the same file as long as all the jobs have the same ASCII export configuration. If the option is checked, column headers are written to the top of the file when the file is first created. From that point on, only data is appended to the file (not headers). Note: Beware that if you later change the ASCII export configuration without opening a new file, the file header may no longer accurately reflect the contents of the file. When differences are exported, they are relative to the standard to which the sample is linked, NOT the standard currently being displayed in your data views. Options > Data Send The OPTIONS > DATA SEND command opens a submenu with two commands: SEND DATA and CONFIGURE. The SEND DATA option initiates sending the readings that are currently highlighted in the Job Tree in the format that was chosen using the CONFIGURE command, described below. You are first prompted for the output device, and then the data is sent to the device when you click OK. 112 EasyMatch QC User’s Manual Version 3.8 Figure 177. Data Send COM Port Selection The CONFIGURE option allows you to choose the parameters you would like to send when DATA SEND is selected. The screen below is obtained. Figure 178. Data Send Configuration The information currently selected for sending is displayed on the left side of this window, and all the available parameters are listed on the right side of the window. Select each desired item from the drop-down menus on the right side of the window and then click on THE LEFT ARROW (<<) button nearest the item to move the item into the SELECTED ITEMS list. HIGHLIGHT EACH ITEM to delete on the left side of the window and click the RIGHT ARROW (>>) button to remove it from the list. The UP ARROW and DOWN ARROW buttons allow you to move selected items up or down the list. Enter the device definition for the send in the box below AUTO SEND USES THIS PORT. Click CONFIGURE to define all COM port parameters. Click OK when all selections have been made. 113 EasyMatch QC User’s Manual Version 3.8 Figure 179. Data Send COM Port Configuration Each job may have its own data send configuration. Multiple jobs may be sent to the same device if the device is ready. When differences are exported, they are relative to the standard to which the sample is linked, NOT the standard currently being displayed in your data views. Options > Custom Indices Custom indices is available in EasyMatch QC 4.96.08 and above. Some softkey licenses might not include the Custom Indices feature. In this case, you can contact [email protected] to request new softkey. In EasyMatch QC, go to OPTIONS > CUSTOM INDICES, and create the desired modified-pathlength indices or add reflectance/transmittance data into the indices list. Indices available for pathlength modification are APHA, ASBC, ASTM D1500, Chinese Acid Wash Color, EBC, EP, FAC, Gardner, Iodine, JP, Saybolt, and USP. After these custom indices are created, they are shown in the Bias Configuration list so that user modify the bias and gains. Figure 180. Select Custom Index After custom indices are added in the above dialog, right click on the Color Data table and click CONFIGURATION, user will see all the custom indices listed under indices category. 114 EasyMatch QC User’s Manual Version 3.8 Figure 181. Select New Custom Index for CDT Screen Any transmittance/reflectance and absorbance data from 400nm to 700nm can be added into indices list. Options > Application Preferences The OPTIONS > APPLICATION PREFERENCES command allows you to set various preferences concerning your use of the software. These preferences apply globally when EasyMatch QC is in use, no matter which job or jobs are open. Figure 182. Global Preferences Menu On the UNITS tab shown above, choose the date format and type of length units (English or metric) you wish to use. 115 EasyMatch QC User’s Manual Version 3.8 Figure 183. Global Preferences for Illuminants On the ILLUMINANT/OBSERVERS tab, choose the three ILLUMINANT/OBSERVER combinations you would like to use in new data views by default. These illuminants may later be changed in individual views as desired. Figure 184. Global Preferences for Language On the LANGUAGE SETTINGS tab, you may set the language in which the software text will presented. Choices are ENGLISH, SPANISH, GERMAN, ITALIAN, FRENCH, JAPANESE, and CHINESE. Note: The keyboard shortcut Ctrl + E returns the software to English. Figure 185. Global Preferences - Default Job Template 116 EasyMatch QC User’s Manual Version 3.8 On the STARTUP DEFAULTS tab, you may indicate the name of the job template you would like to use by default when new jobs are opened. Clicking the button with three dots on it allows you to browse for the appropriate template file. Figure 186. Global Preferences - Open Job Template You may also choose to have the software open a specific job or jobs each time it is booted. Clicking the button with three dots (…) on it allows you to browse for the appropriate job file(s). To select more than one job to open, press and hold the CTRL KEY on your keyboard while CLICKING YOUR MOUSE on each desired job. Figure 187. Global Preferences - Browse for Job File Indicate whether you wish software LOG-IN to be required (checked) or not required (unchecked) for the software to open. Note: When Login Required is checked, the default administrator user name ‘admin’ and password ‘hunterlab’ may be used for initial entry to the software and configuration of user accounts. When the KEEP SAMPLE MEASUREMENT WINDOW OPEN box is checked, a READ button is added to the Read Sample screen and this window remains open after a sample is read. You may then click READ to make another reading. This change applies to the reading of samples only, not standards. 117 EasyMatch QC User’s Manual Version 3.8 Figure 188. Global Template - Sample ID When the RETAIN IDS IN SAMPLE MEASUREMENT WINDOW is checked, the last sample ID used is displayed on the Read Sample screen when another sample reading is initiated. This allows you to use the ID again or modify it without having to retype it. This retention applies to the reading of samples only, not standards. When the LOCK SENSOR TO JOB box is checked, the current job may be used to hold only readings made with the sensor type (i.e., LabScan XE or UltraScan PRO) attached to the job. Measurements made with other sensor types may not be read or recalled into this job. When the LOCK STANDARDIZATION MODE TO JOB box is checked, the current job may be used to hold only readings made using the standardization mode (i.e., RSIN, 1.000-inch area of view, UV filter nominal) attached to the job. In fact, when a job that is locked to a standardization mode is opened or made active, the sensor automatically switches to the locked standardization mode without requiring use of the SENSOR > SET MODES command. If both boxes are checked at the same time, the current job will be locked to a single sensor type and standardization mode. When either or both boxes are checked, a second level of status bar is shown at the bottom of the EasyMatch QC screen, showing the job’s sensor type and the job’s standardization mode. The lower status bar continues to show the current sensor and standardization mode. Figure 189. Global Preferences Current Sensor & Standardization Mode Options Options > External Trigger In EasyMatch QC, go to OPTIONS > EXTERNAL TRIGGER and set up the device. Select ENABLE EXTERNAL 118 EasyMatch QC User’s Manual Version 3.8 TRIGGERING and select the type of connection. Figure 190. External Trigger Configuration Choose Target Choose EASYMATCH QC or ESSENTIALS as the target for the external trigger . Communication Select TCP/IP or Serial connection to the triggering device. Select CONNECT when this has been configured. Standardization Select the MODE TYPE from the pull-down menu. Then press STANDARDIZE. The instrument responds with STANDARDIZATION SUCCESSFUL. 119 EasyMatch QC User’s Manual Version 3.8 Figure 191. Standardization Using External Trigger Read Command Setup READ STANDARD and READ SAMPLE. Enter the specimen ID, Product ID and if needed, Extra ID. Once the reading has been completed, the instrument will show MEASUREMENT SUCCESSFUL. Figure 192. Standard Measurement by External Trigger Commands for Triggering Device The below is the typical command frame sent from External Triggering tool. $,<CMD>,<COMMAND INFO>,# Where, <CMD> is the Command String <COMMAND INFO> The associated Command Parameters $ and # are the Beginning and End Markers of the Command frame. 120 EasyMatch QC User’s Manual Version 3.8 For every command received from the Triggering Tool, the Essentials-Vista response will be in the below format: “$ Essentials - <ACKINFO> #” Where, <ACKINFO> can be “Connected to Server”, “Succeeded”, “Failed”, “Standardization Expired! Please Standardize to continue”, the name of the connected sensor, etc.. ‘Get Current Sensor’ Command Structure: $,GETCURRENTSENSOR,# If the connected sensor type is received as “Vista”, then only the standardization command is sent to Essentials. ‘Standardize’ command structure: $, <CMD>, <MODE TYPE>, <mode type>, <HAZESTATUS>,<haze status>, # Where, <CMD>: STANDARDIZE <Mode Type>: ‘RTRAN – Regular Transmittance’ (or) ‘TTRAN – Total transmittance’. For EZMQC: This field is not applicable. The Standardization is performed as per the current selected mode in Modes configuration dialog. <Haze Status>: 0 for ‘without Haze’ and 1 for ‘with Haze’ Example: ex1: $,STANDARDIZE,HAZESTATUS,0,# --->For EZMQC application ex2: $,STANDARDIZE,MODETYPE,RTRAN – Regular Transmittance,HAZESTATUS,0,# --->For Essentials-Vista Measure’ command structure: $, <CMD>, <MEASUREMENT TYPE>, <STD>, <std name>, <SMP>, <sample name>, <PID>, <Product ID>, <EID>, <Extra ID>, # Where, <CMD>: MEASURE <MEASUREMENT TYPE>: 1 for ‘Read Standard’ and 2 for ‘Read Sample’ The <Product ID> & <Extra ID> represent to associated with the respective measured Standard or Sample. Example: a) Read Standard (Only for EZMQC): ex1:$,MEASURE,1,STD,Standard1,PID,prodID1,EID,extraID1,# ex2: $,MEASURE,1,STD,Standard1,# -- with no optional PID &EID. b) Read Sample (For EZMQC): ex1:$,MEASURE,2,STD,Standard1,SMP,sample1,PID,pid1,EID,eid1,# ex2: $,MEASURE,2,STD,Standard1,SMP,sample1,# -- with no optional PID & EID c) Read Sample (For EZMQC and Essentials): ex1: $,MEASURE,2,SMP,sample1,# -- with no Standard and optional PID & EID Options > System Configuration The OPTIONS > SYSTEM CONFIGURATION command yields a submenu that allows you to choose to configure user accounts and privileges or configure data storage. These parameters will be used throughout the software, no matter what job or jobs are in use. Access Privileges User Manager The user manager allows you to configure accounts for system users and assign specific software privileges to those accounts. When the USER MANAGER screen appears, you may click on USERS to view the users already in the system. 121 EasyMatch QC User’s Manual Version 3.8 Figure 193. User Manager Note: The User Manager command is available only if Login Required is checked on the Startup Defaults tab available by choosing Application Preferences from the Options menu. RIGHT-CLICK on USERS to display a pop-up menu with one command: NEW USER. New User brings up a screen on which you may create a new user account. Click CREATE to create the account. This user may log into EasyMatch QC using the account name and password chosen here. Figure 194. User Manager: New User On the right side of the screen, RIGHT-CLICK on a user name to receive a pop-up menu containing the following commands: o SET PASSWORD: Choose this command and enter the old password then the new password twice to change this user’s password. Figure 195. User Manager: Set Password o EDIT: Choose this command to edit the full name for this user. 122 EasyMatch QC User’s Manual Version 3.8 Figure 196. User Manager: Edit User Name o DELETE: Choose this command to delete this user. o ADD TO GROUP: Choose this command to obtain a list of available groups. CLICK ON THE GROUP DESIRED and then OK to add this user to the chosen group. Figure 197. User Manager: Select Group Click on GROUPS to view the groups already in the system. Figure 198. User Manager: View Groups RIGHT-CLICK on GROUPS to display a pop-up menu with one command: NEW GROUP. NEW GROUP brings up a screen on which you may create a new group. Click ADD to add users to the group and REMOVE to remove any highlighted users from the group. Click CREATE to create the group. 123 EasyMatch QC User’s Manual Version 3.8 Figure 199. User Manager: Add New Group Click SET PRIVILEGES to configure the privileges for the group. Each menu command may be allowed or prohibited individually. Click the plus (+) sign next to an item to open a list of its subitems. Check the box near each command that should be allowed and clear the box for each command that should be prohibited. Figure 200. Add New Group Privileges For 21 CFR 11 compliance, the following commands should be prohibited for users that are not the system administrator: o File > Delete Measurement from Database o File > Time Synchronization o Edit > Cut o Edi > /Delete o View > Audit Log 124 EasyMatch QC User’s Manual Version 3.8 o Sensor > Set Interval o Options > User Manager o Options > Data Storage. You may wish to further limit the privileges of lower-level operators. On the right side of the User manager screen, RIGHT-CLICK ON A GROUP NAME to receive a pop-up menu containing the following commands: o ADD USER: Choose this command to add an existing user to this group. A list of users that have not yet been assigned to a group appears. Select the desired user and click ADD. Figure 201. User Manager: Add Users o EDIT PRIVILEGES: Choose this command to edit the privileges of this group. The same screen that was displayed when you initially set the privileges is received. o DELETE: Choose this command to delete this group. Data Storage The DATA STORAGE command allows you to indicate the location where your database will be stored and other parameters related to the database. Note: Use of a database is optional. 125 EasyMatch QC User’s Manual Version 3.8 Figure 202. Default Storage Location CHOOSE THE TYPE OF DATABASE you wish to use and indicate the LOCATION OF THE DATABASE, which may be housed at any location accessible by your computer. If required for database access, enter the user name and password for the database. If you wish to have all measurements saved to the database automatically as they are made, check AUTO SAVE MEASUREMENT. You may also have all measurements in all open jobs automatically saved by checking AUTO SAVE JOB. If you wish to use the same sample and standard IDs multiple times in a single job or database without receiving an error message, check ALLOW DUPLICATE NAMES. If you wish to periodically have the software back up your database automatically, check DATABASE BACKUP and indicate where you would like the back-up file to be stored and how often. Indicate the path where you would like your jobs saved by default and, if you wish to import an EasyMatch Textiles database, check SELECT TEXTILES DATABASE and indicate the database and its location. Click OK. When FILE > SAVE MEASUREMENT TO DATABASE is then chosen, the chosen measurement(s) will be saved to the configured database. Note: Microsoft Access need not be installed on the system to use the Access database feature. Create and configure a SQL database as described in the Appendix. Server Settings (ER Version Only) At the end of the installation of the EasyMatch QC-ER Client software, the server name was entered. However, if the server name should change or require re-entry, use the SERVER SETTINGS command to do so, then click OK. Figure 203. ER Version: Server Settings 126 EasyMatch QC User’s Manual Version 3.8 e-Signature Settings (ER Version Only) Each job will be electronically signed with the name of the signer, date and time of signing, and the meaning of the signature. The electronic signatures applied to the jobs are linked to the jobs, may not be deleted, and are always available for display or printing. Only a user with e-signature access can sign a job file. Options > Customize Toolbar The OPTIONS > CUSTOMIZE TOOLBAR command allows you to modify the ICONS OF THE BUTTONS on the toolbar and the COMMANDS PERFORMED BY THE BUTTONS on the toolbar. This configuration applies to this installation of the software, no matter what job or jobs are in use. Figure 204. Defining the Toolbar In the Button to change box, SELECT THE BUTTON YOU WISH TO CHANGE and then CLICK THE ICON for the button in the Icon box. Then select a NEW COMMAND for that button from the Command box. Click CHANGE to initiate the changes. Click Reset ALL to return all buttons to their default settings. Click CLOSE to exit the window after you have made your changes. Options > EasyGroup The OPTIONS > EASYGROUP command allows you to launch HunterLab’s tapering and grouping program, EasyGroup, if you purchased and installed that package. Refer to the User’s Guide for EasyGroup for complete operational instructions. Options > Import EasyGroup Sequence The OPTIONS > IMPORT EASYGROUP SEQUENCE command allows you, once a collection of samples has been grouped or tapered in EasyGroup, to bring the grouping or tapering information back into EasyMatch QC and display it as a new column in the Color Data Table view. The column header is ‘GROUP’ for grouped samples and ‘GROUP/SEQUENCE’ for group + tapered samples. Note: EasyGroup version 1.82 or higher is required to use this feature. 127 EasyMatch QC User’s Manual Version 3.8 128 EasyMatch QC User’s Manual Version 3.8 The Sensor Menu From the SENSOR MENU, you can select and configure a new sensor, set its standardization modes, and standardize the sensor. You may also set the standardization interval for the instrument and calibrate the optional UV filter. The functions available through the SENSOR MENU are described in the remainder of this chapter. Sensor > Install/Configure The SENSOR > INSTALL/CONFIGURE command allows you to install a new sensor or change the configuration of an existing sensor. The Sensor Manager appears first. Figure 205. Sensor Manager Click ADD SENSOR to install a new sensor. The Setup Sensor screen appears on which you can select your instrument model, name the sensor (using the sensor’s serial number is recommended), and indicate the communications port where it will be installed. Click NEXT when these items are as desired. Figure 206. Configuring Sensor Type & ID Next, you are prompted to configure a standardization mode for the sensor. ENTER A NAME FOR THE MODE AND indicate the OTHER MODE PARAMETERS. Check the box next to STANDARDIZE NOW if you would like standardization to proceed immediately upon completion of sensor configuration. Click NEXT or FINISH to complete the installation. For instruments with more than one available standardization mode, you will receive a check box asking if you would like to set up additional modes. Do so if desired. Then you are either prompted 129 EasyMatch QC User’s Manual Version 3.8 through the standardization process (as described later in this chapter) or returned to the Sensor Manager screen. Figure 207. Setup Mode for Sensor TO DELETE A SENSOR, HIGHLIGHT it in the Sensor Name box and click REMOVE. Confirm that you really wish to remove the sensor by clicking YES. Figure 208. Sensor Deletion TO RENAME A SENSOR, HIGHLIGHT it in the Sensor Name box and click RENAME. Type the new name into the New Name box and click OK to implement the change. Figure 209. Renaming a Sensor TO SET THE STANDARDIZATION MODES for a sensor, HIGHLIGHT it in the Sensor Name box and click SET MODES. 130 EasyMatch QC User’s Manual Version 3.8 Figure 210. Set Modes for a Sensor TO CONNECT TO A DIFFERENT SENSOR than the one that is currently in use, first check your sensor cables to ensure that they are linking the desired new sensor to the computer. Then, HIGHLIGHT the desired new sensor name in the Sensor Name box and click CONNECT. The new sensor will then be in use. Sensor > Standardize The SENSOR > STANDARDIZE command yields prompts that lead you through the standardization procedure for the standardization mode currently selected using the SET MODES command. The prompts will appear slightly differently depending on the instrument in use and the standardization mode. The keyboard shortcut for this command is F4. First, the bottom-of-scale must be set. Click NEXT when you are ready to read the zero. Figure 211. Standardization: Bottom of Scale Then, the top-of-scale must be set. Click NEXT when you are ready to read the standard or blank. 131 EasyMatch QC User’s Manual Version 3.8 Figure 212. Standardization: Top-of-scale Click FINISH when standardization is complete. Figure 213. Confirming that Standardization is Completed Note: It is highly recommended that a Green Tile test be performed after standardization. Do not proceed without successfully passing the Green Tile Test. If needed, contact the Service Department of HunterLab. For more instruction on the Green Tile Test click here. Sensor > Set Modes The SENSOR > SET MODES command allows you to configure standardization modes for the currently active sensor. 132 EasyMatch QC User’s Manual Version 3.8 Figure 214. Set Modes for a Sensor To add a new mode, click the ADD MODE button. To remove an already configured mode, highlight it in the Mode Names box and click REMOVE. To standardize in a mode, highlight it in the Mode Names box and click STANDARDIZE. Follow the prompts to complete standardization. Sensor > Set Interval The SENSOR > SET INTERVAL command allows you to set the standardization interval for the currently active sensor. When that interval has elapsed, the software will prompt you to standardize before more readings can be made. The interval indicated here applies to EasyMatch QC regardless of the job currently in use. Figure 215. Restandardization Interval Note: A standardization interval of no longer than 8 hours is recommended. If your installed sensor is a LabScan XE, you may also set the secondary standardization interval, which is the interval at which the secondary white tile ‘paddle’ is automatically checked. Zero disables reading of this tile entirely. Figure 216. Secondary Standardization for LabScan XE Sensor > UV Calibration The SENSOR > UV FILTER CALIBRATION command appears only when the connected instrument is a LabScan XE, UltraScan PRO, UltraScan VIS or Agera with the UV control option installed. For Agera, please refer to the Agera Supplemental Manual for EasyMatch QC. UV Filter Calibration: The instrument must also be standardized in a mode for which the UV Filter Position is indicated as Calibrated. 133 EasyMatch QC User’s Manual Version 3.8 Note: Before calibrating the UV filter of a Agera, UltraScan PRO, or UltraScan VIS, standardize the instrument in the mode referenced on the label of the fluorescent standard. If the label does not specify a standardization mode, standardize in RSEX. UV filter calibration should be performed weekly and after lamp replacement. Once UV FILTER CALIBRATION is chosen from the SENSOR MENU, the following screen appears. Figure 217. Calibration of UV Filter: 457 Brightness Enter the standard’s assigned value into the appropriate box on the UV Calibration screen. This value has been assigned at the factory if you are using the HunterLab-supplied fluorescent standard. Choose whether the value is for BRIGHTNESS 457, WHITENESS INDEX CIE (and the illuminant/observer combination), WHITENESS INDEX GANZ, or Z%. The scale used will be WI Ganz for a HunterLab standard. Figure 218. Calibration of WI GANZ Select CALIBRATE UV to automatically adjust the UV filter to the appropriate position after several readings of the fluorescent standard. First you are prompted to place the fluorescent standard. Figure 219. Prompt for Calibration of UV Filter Place the fluorescent standard at the instrument port. For the UltraScan PRO, or UltraScan VIS, center spot 3 at the reflectance port. Use the dotted guides on the labeled side of the standard to properly center the standard under the sample clamp. Select READ to read the fluorescent standard with the UV filter in the position indicated at the bottom of the screen. If desired, the slider bar may be used to change the filter position between manual readings. Click STANDARDIZE to initiate standardization. You will be returned to the UV Calibration screen after standardization is complete. For the UltraScan PRO, and UltraScan VIS, measure both spot 3 and spot 4 of the fluorescent standard every six months. Compare the results. If spot 3 has faded beyond tolerable limits for your application, use spot 4 for UV filter calibration from this point on and order a new fluorescent standard (HL#A02-1011-126 [calibrated] for UltraScan PRO, and UltraScan VIS. 134 EasyMatch QC User’s Manual Version 3.8 Note: If you choose to employ the ‘calibrated’ filter position, this position should be employed for all routine measurements using this instrument. If you calibrated the UV filter with an open port and then you wish to use a cover glass, you must recalibrate the UV filter with the cover glass in place. Sensor > Configure Multi Mode The SENSOR > CONFIGURE MULTI MODE command appears only when the connected instrument is a LabScan XE, UltraScan PRO, UltraScan VIS or Agera. This command is used to set up the process by which the instrument can standardize and read in two separate but similar modes when the standardization and read commands, respectively, are given. The following screen first appears that allows you to indicate how you would like the multimode readings to be performed. Figure 220. Multimode Configuration When this screen first opens, all the standardization modes you have configured for your instrument (using SENSOR > SET MODES) are listed in the Available Modes box. Click on the first mode you wish to use and then click the INCLUDE button to move the mode from the Available Modes box to the Selected Modes box. Only modes that are similar enough to the already-selected mode that no user intervention is required for the dual measurements will remain available. Select the second desired mode and click INCLUDE again to include it. Click OK. Then, when the OPTIONS > READ METHOD is set as Multiple Read Mode, the instrument will be standardized in the two modes when you initiate standardization and will read in the two modes when you initiate readings. The multiple readings are placed in the job as separate measurements. Figure 221. Multimode: Mode Selection 135 EasyMatch QC User’s Manual Version 3.8 Sensor > Import Logged Reads The SENSOR > IMPORT LOGGED READS command appears only when the connected instrument is a ColorFlex EZ or MiniScan EZ. There must be items saved to the instrument Data log to use this command. The Data log screen appears first. Figure 222. Data log: Import Readings Click RETRIEVE DATA to copy all the measurements stored in the instrument’s Data log to the Data log screen. Figure 223. Data log: Available Data Once the measurements are shown, the remainder of the buttons at the bottom of the screen become active and serve the following functions: o SORT BY LOG: Causes the measurements shown in the Data log window to be sorted by their instrument Data log ID numbers for easier viewing. o SORT BY SETUP: Causes the measurements shown in the Data log window to be sorted by their instrument setup numbers for easier viewing. o SELECT ALL: Selects (highlights) all the measurements shown on the Data log screen so that the COPY TO JOB or COPY TO DATABASE command may be applied to all of them at once. (The alternative to SELECT ALL is to use the Windows convention of clicking on a single item to select it, CTRL + clicking on multiple items to select them, or SHIFT + clicking on the first and last of a list of items to select all the items between. 136 EasyMatch QC User’s Manual Version 3.8 o COPY TO JOB: Places the measurements that are currently selected into the active job. Standards are automatically placed in the job as standards. You are prompted to indicate the standard under which samples should be saved. o COPY TO DATABASE: Places the measurements that are currently selected into the database. Standards are saved as standards and samples as samples, and the Data log ID number is used as the item ID. The measurements copied to the job or EasyMatch QC database are NOT deleted from the instrument’s Data log. If you wish to delete them, you must do so manually though the instrument firmware. Sensor > Configure Setups The SENSOR > CONFIGURE SETUPS command appears only when the connected instrument is a ColorFlex EZ or MiniScan EZ. When you select it, the Setup Groups window appears where you can choose to create, edit, or delete setup groups and upload, modify, and download individual setups. Figure 224. Configure Setups: Groups Upload When you click UPLOAD, all the setups stored in the instrument are brought into EasyMatch QC. These setups can then be edited, if desired. The setups can also be saved as a setup group by typing a name into the white box or selecting a name from the drop-down list and clicking SAVE. Later, you can select the desired group and click GET to retrieve that saved group of setups or DELETE to delete the group of setups. Download When you click DOWNLOAD, the setups in the current EasyMatch QC setup group are sent back to the instrument. Edit When you click EDIT, the Product Setup Configuration screen appears. 137 EasyMatch QC User’s Manual Version 3.8 Figure 225. Product Setup by Instrument: ColorFlex EZ (left), MiniScan EZ (right) Use the scroll bar next to Setup Number or type a setup number into the box to CHOOSE A SETUP with which to work. If you wish to begin working with the version of the setup that is already resident in your instrument, click RETRIEVE. If you wish to work with the version of the setup that is shown on-screen, do not click RETRIEVE. Alter the setup parameters as desired. The parameters and selections available are the same as those configured through your instrument firmware. If you are using a physical standard, you may click the Read Standard button to read the standard to be saved with the setup using your instrument or RECALL STANDARD to recall a standard from your EasyMatch QC database to be saved with the setup. When all parameters are as desired for this setup, click UPDATE SENSOR to send the setup to your instrument. You may retrieve all the setups from the instrument at once using the RETRIEVE ALL button or send all the setups back to the instrument at once using the UPDATE ALL SETUPS button. Sensor > Diagnostics The SENSOR > DIAGNOSTICS command opens to a submenu allowing access to the various diagnostic tests available to verify performance of your instrument. Those tests are described below. Green Tile Test Note: This is available for all instruments except Vista. When DIAGNOSTICS > GREEN TILE TEST is selected, a special job is opened in EasyMatch QC and, if this is the first time you have run the green tile test for this instrument, the following screen will be shown. ) 138 EasyMatch QC User’s Manual Version 3.8 Figure 226. Green Tile Test As prompted, ENTER THE VALUES READ AT FACTORY for your green tile in XYZ. These values can be found on the back of the green diagnostics tile. Once all three numbers have been entered, click OK. A standard called GREEN TILE VALUES READ AT FACTORY will be created in a Green Tile Test Job. The following prompt then appears. Figure 227. Reminder to Install Standard Port Plate As instructed, make sure that the standard port plate for your instrument is currently installed. This will generally be the port insert with the largest opening that is not covered by glass. Click OK when this port plate is installed. If you need to adjust your green tile values, click REVISE GREEN TILE VALUES before clicking OK. Follow the on-screen prompts to PERFORM A NORMAL STANDARDIZATION IN REFLECTANCE/RSIN MODE. When standardization is complete, the following prompt will be shown. Figure 228. Prompt to Read the Green Tile Center the green tile over the sample port/reflectance port with the colored side facing the instrument. Click OK. The green tile will be read and the measurement added to the green tile check job. Its pass/fail status will also be shown. Should this test FAIL, a different message will appear suggesting actions to take. 139 EasyMatch QC User’s Manual Version 3.8 Figure 229. Results of Diagnostics: Green Tile Click YES to close the Green Tile Job. The following pdf report will appear documenting the results of the test. As an option, this report can be printed as a hardcopy for your records. In addition, this GREEN TILE REPORT is automatically saved in C:\HunterLab\EasyMatchQC-ER Client\Reports or C:\HunterLab\EasyMatchQC\Reports with a unique data/time stamp for future reference. Figure 230. Diagnostics Report FILE > EXIT to close the report and finish the test. Repeatability Test When DIAGNOSTICS > REPEATABILITY TEST is selected, a special job is opened in EasyMatch QC and the following prompt is shown. ) Figure 231. Reminder to Use Standard Port Plate 140 EasyMatch QC User’s Manual Version 3.8 As instructed, make sure that the standard port plate for your instrument is currently installed. This will generally be the port insert with the largest opening that is not covered by glass. Click OK when this port plate is installed. Follow the on-screen prompts to PERFORM A NORMAL STANDARDIZATION IN REFLECTANCE/RSIN MODE. When standardization is complete, the following prompt will be shown. Figure 232. Repeatability Test: White Tile Center the white calibrated tile over the sample port/reflectance port with the white side facing the instrument. Click OK. The Repeatability Test screen appears. Figure 233. Repeatability Test: White Tile Readings The white tile is read as a standard and then twenty times as a sample. The color values for each reading are displayed on the Repeatability Test screen as they are made. The pass/fail result for each reading is also shown. Once all the readings have been made, you are provided with instructions concerning what you should do if your instrument fails the repeatability test. Click YES if you wish to save the test data to the job or NO if you wish the data to be discarded. The pass/fail tolerances for each instrument are listed below. Instrument Pass Criteria for Repeatability Aeros dE* ≤ 0.02 Agera dE* ≤ 0.02 ColorFlex EZ dE* ≤ 0.05 LabScan XE dE* ≤ 0.09 MiniScan EZ dE* ≤ 0.05 UltraScan PRO dE* ≤ 0.03 141 EasyMatch QC User’s Manual Version 3.8 UltraScan VIS dE* ≤ 0.03 Vista dE* ≤ 0.02 Click YES to close the Repeatability Job. The following pdf report will appear documenting the results of the test. As an option, this report can be printed as a hardcopy for your records. This REPEATABILITY TEST REPORT is automatically saved in c:\HunterLab\EasyMatchQC-ER Client\Reports with a unique data/time stamp for future reference. Figure 234. Report on Repeatability Test FILE > EXIT to close the report and finish the test Didymium Filter Test When DIAGNOSTICS > DIDYMIUM FILTER TEST is selected, a special job is opened in EasyMatch QC and the following prompt is shown. Note: This is available for Vista, UltraScan PRO, UltraScan VIS and Vista only.) Figure 235. Didymium Filter Test: Reminder to Use Standard Port Plate As instructed, make sure that the standard port plate for your instrument is currently installed. This will generally be the port insert with the largest opening that is not covered by glass. Click OK when this port plate is installed. 142 EasyMatch QC User’s Manual Version 3.8 Follow the on-screen prompts to PERFORM A NORMAL STANDARDIZATION IN RTRAN mode. When standardization is complete, the following prompt will be shown. Figure 236. Didymium Filter Test: Place filter at RTRAN port Screw the didymium filter, in its threaded tune, into the matching threads at the lens. Shut the transmittance compartment door. Click OK when you have done so. The Didymium Filter Test screen appears. Figure 237. Inserting the Didymium Filter at RTRAN port (lens side) Figure 238. Didymium Filter Test: Enter Data Sheet Values As instructed, ENTER THE 430 NM AND 570 NM TRANSMITTANCE VALUES from the Didymium Filter area of your tile data sheet. For an UltraScan PRO, also ENTER THE 820NM READING. Click ACCEPT to enter these values. (Click ACCEPT on future instances of the test to acknowledge the correct values). Twenty readings of the didymium filter will be made and then averaged. 143 EasyMatch QC User’s Manual Version 3.8 Figure 239. Display of Didymium Filter Readings & Average A pass/fail assessment is provided for the averaged reading along with instructions concerning what to do if your instrument failed the test. Click YES if you wish to save the test data to the job or NO if you wish the data to be discarded. The pass/fail tolerances for each instrument are listed below. Sensor • 430nm 570nm UltraScan VIS Average reading ≤ 1.05 %T Average reading ≤ 3.15 %T UltraScan PRO Average reading ≤ 1.25 %T Average reading ≤ 4.55 %T Vista Average reading ≤ 1.05 %T Average reading ≤ 3.15 %T For the UltraScan PRO, the 820-nm average reading differs from the entered 820 nm value by no more than 2.0 %T else fail. The following prompt is given next. Figure 240. Reminder to Remove the Didymium Filter Remove the didymium filter from the lens port and click OK. Click YES to close the Didymium Filter Job. The following pdf report will appear documenting the results of the test. As an option, this report can be printed as a hardcopy for your records. This Wavelength Accuracy Didymium Filter Report is 144 EasyMatch QC User’s Manual Version 3.8 automatically saved in C:\HunterLab\EasyMatchQC-ER Client\Reports or C:\Hunterlab\EasyMatchQC\Reports with a unique data/time stamp for future reference. Figure 241. Report on Didymium Filter Readings File > Exit to close the report and finish the test. Advanced Diagnostics Note: This is available for most instruments except Vista, Aeros and Agera Advanced diagnostics can be found in Vista/Aeros/Agera Essentials software. When DIAGNOSTICS > ADVANCED DIAGNOSTICS is selected, a utility by which the various hardware components of your instrument may be checked is opened. Example screens for the LabScan XE are shown below. These screens will appear slightly differently for other instrument types. Figure 242. Instrument Status Information 145 EasyMatch QC User’s Manual Version 3.8 Figure 243. Advanced Diagnostics: Read Photometric Data Figure 244. Advanced Diagnostics: Standardize Figure 245. Advanced Diagnostics: Motor Test Click MOTOR TEST to test the instrument motors. Click the button to the left of each test name to toggle between RUN (PERFORM THE TEST) and SKIP (DO NOT PERFORM THE TEST), then click START to begin the chosen test(s). These tests are not available for ColorFlex EZ, , and MiniScan EZ, as there are no motors in these instruments to test. Results are shown at the bottom of the screen. Figure 246. Advanced Diagnostics: Signal Level Test 146 EasyMatch QC User’s Manual Version 3.8 Click SIGNAL LEVEL and then click FLASH to display raw signal level counts for the sample that is currently at the sample port. Check any of the available boxes to show the data a different way, such as in a graph. Predictive Diagnostics Predictive Diagnostics are available for each sensor type under SENSOR > DIAGNOSTICS > PREDICTIVE. Figure 247. Predictive Diagnostics Settings 1.1 Setup the reminder interval (in days) for each diagnostic test (i.e.. Repeatability, Green Tile, and Didymium Filter). Next select Disable alerts or enable alerts. The default value is to "Disable Diagnostics Test Alerts". 1.2 View trend plots for each diagnostic test (e.g. Repeatability, Green Tile, and Didymium Filter). For each trend plot, select the time range, then click Show to display the data. Figure 248. Green Tile Diagnostic Trend 2. All collected predictive diagnostics data are saved into a database. This data is specific to an instrument and can include alert reminders, didymium data, gloss tile data, green tile data, trend names, and white tile data. 147 EasyMatch QC User’s Manual Version 3.8 The Window Menu From the WINDOW MENU, you can arrange the data views on the screen, open a new window, or go to a specific job. The functions available through the WINDOW MENU are described in the remainder of this chapter. Window > New Window The WINDOW > NEW WINDOW command allows you to open a second window for the current job on your EasyMatch QC screen. This creates additional displays for the job, without running out of room on the screen. Figure 249. Creating a New Window Window > Cascade The WINDOW > CASCADE command moves the current jobs so that they are cascaded one on top of the other and only the title bar of each job is visible. You may CLICK ON ANY OF THE TITLE BARS to show that job as the top job. Pressing CTRL and TAB simultaneously toggles each job to the top in turn. Figure 250. Cascading of Windows 148 EasyMatch QC User’s Manual Version 3.8 Window > Tile The WINDOW > TILE command moves the current jobs so that they are displayed on the screen with one on top of the other. The sizes of the jobs are adjusted so that they all fit on the screen. The currently selected job is always placed in the upper portion of the screen area. Figure 251. Window Tile for Multiple Windows Window > List of Open Jobs You can make any job active by selecting it from the WINDOW MENU. A check will appear next to that job in the WINDOW MENU, the title bar of the active job will be highlighted, and the job will come to the front. 149 EasyMatch QC User’s Manual Version 3.8 The Help Menu From the HELP MENU, you can view the EasyMatch QC help file and information about your version of the program. The functions available through the HELP MENU are described in the remainder of this chapter. Help > Help Topics The HELP MENU > HELP TOPICS command opens the EasyMatch QC help file in which you can locate information on how to operate your instrument and software by searching for keywords, using the index, or using the table of contents. To use the help file, you must have a web browser (such as Internet Explorer or Netscape Navigator) installed on your computer. The keyboard shortcut for this command is F1. Note: If you are running Windows XP with Service Pack 2 installed and are viewing the help file using Microsoft Internet Explorer, you will need to allow blocked content to view the help correctly. See the yellow bar at the top of the browser for instructions on how to do so. Help > HunterLab on the Web The HELP > HUNTERLAB ON THE WEB command opens your web browser and takes you to the HunterLab web site in case you need to get information on color measurement, instruments, or technical assistance. Help > About The HELP > ABOUT command brings up the About EasyMatch QC Software box specifying the VERSION of EasyMatch QC being run and giving copyright and contact information. Figure 252. Help Menu: About Help > License Information The HELP > ABOUT > LICENSE INFO command brings up a box specifying the type of SoftKey license and the instrument interface. For information on installing a SoftKey license, see HOW TO INSTALL EASYMATCH QC. 150 EasyMatch QC User’s Manual Version 3.8 Figure 253. License Information 151 EasyMatch QC User’s Manual Version 3.8 APPENDIX A: Software Messages Occasionally you may receive an error or warning message on your computer screen. A message can help you determine if you have a setup, instrument, or software problem. This appendix lists some of the more prevalent messages for EasyMatch QC. If any error message is displayed which is not described in this chapter, it may be a Windows message. Refer to your Windows User’s Guide for a possible explanation. Contact HunterLab Technical Support if the error message cannot be found or the problem persists. Please read ‘When You Need Assistance’, prior to telephoning HunterLab. Message Text Meaning Possible Solution(s) An error occurred during the move data process. This message indicates that one or more files are not registering in the system (Windows) registry during the installation process. This generally occurs when you are attempting to install while logged into Windows using an account that does not have administrator privileges. Cancel the installation and log into Windows using an administrator account, then perform the installation. Cannot execute the application due to Invalid license. Please contact HunterLab. You are attempting to open EasyMatch QC with a defective hardware key connected to your computer. . Obtain a new key from HunterLab. Did not receive a status message from the sensor. The sensor is not responding to the software’s attempt to connect to it. Follow the instructions on the screen below the message to check the status of the sensor and its connections. If you are connecting to a MiniScan EZ, confirm that the instrument is turned on. If you are connecting to an UltraScan PRO or UltraScan VIS using a USB cable, also consider whether the FTDI USB-to-serial adapter is installed properly. If, after checking and attempting to connect again, this message is still received, contact HunterLab concerning instrument service. 152 EasyMatch QC User’s Manual Version 3.8 Message Text Meaning Possible Solution(s) Difference data cannot be retrieved from the data log when it is in tristimulus mode. You are attempting to copy a Difference Tristimulus sample from a ColorFlex EZ or MiniScan EZ Data log into a job or into the database. The software does not know what standard values were used to calculate the sample’s difference data. Save all data to the ColorFlex EZ or MiniScan EZ Plus Data log as Spectral Data or Absolute Tristimulus data. Failed to detect HunterLab key. Insert and try again. You are attempting to open EasyMatch QC without the SoftKey connected to your computer. Install the EasyMatch QC key provided with your system onto your computer. Not an EasyMatch QC key. You are attempting to open EasyMatch QC with a hardware key connected to your computer that is either not a HunterLab key or is not programmed to allow access to EasyMatch QC. Install the EasyMatch QC key provided with your system onto your computer. Standard’s standardization mode doesn’t match the sample’s standardization mode. Sample will not be read. You are attempting to link a sample read in one mode (i.e., TTRAN 1.00in with UV filter nominal) to a standard read in another mode (i.e., RSIN 1.00-in with UV filter nominal). If the mode of the sample is correct, link it to a standard read in that mode. The job’s sensor type and the current sensor type do not match. Standard cannot be read. The current job is linked to one sensor type (i.e., LabScan XE), but you are trying to make measurements using a sensor of a different type (i.e., Agera) If the mode of the sample is incorrect, standardize the instrument in the proper mode before reading the sample again. Uncheck ‘Lock Standardization Mode to Job’ in Application Preferences. Open a job that is linked to the sensor type with which you wish to read. Uncheck ‘Lock Sensor to Job’ in Application Preferences. Connect licensed sensor. You have not yet installed a sensor. Please install a sensor if you wish to take measurements. You are opening the software for the first time or for the first time after removing all installed sensors. Use the Sensor > Install/Configure command to install the desired sensor. Your license has expired. Please contact HunterLab. You are attempting to open EasyMatch QC with SoftKey that has expired on your computer. Obtain an updated key from HunterLab and install it onto your computer. No license is activated. Need to activate a license key to use the application. 153 EasyMatch QC User’s Manual Version 3.8 APPENDIX B: Creating and Configuring a SQL Database This appendix describes how to create and configure a SQL database for use with EasyMatch QC. A working knowledge of SQL server is recommended for performing these steps. A copy of SQL Server (Microsoft SQL Server is typical) should be installed first followed by EasyMatch QC, as described in the EasyMatch QC Installation Guide. 1. In SQL Server, select FILE > OPEN and choose to open the script file from the location For 32 bit OS: C:\Program Files\HunterLab\EasyMatchQC\SQL Database Script\EZMQC.sql (or) For 64 bit OS: C:\Program Files (x86)\HunterLab\EasyMatchQC\SQL Database Script\EZMQC.sql” This is the location of the file if you installed EasyMatch QC to the default folder. If you installed elsewhere, you will find the SQL Database Script subfolder in your installation folder. 2. Execute the EZMQC.sql script file and the EZMQC SQL database will be created. A separate database for each sensor type based on the sensor name, “tblMeasurements_XXXX” is also created. 3. You can use the SQL Server to view this database and see that tables have been created within it. 4. In the TREE VIEW, expand the SECURITY BRANCH. 5. Right-click on SECURITY > LOGINS and choose NEW LOGIN. 6. Change Default Database to EZMQC and do USER MAPPING to set each User with data read and write roles for the EZMQC SQL database. Figure 254. Creating an SQL Database 7. Close SQL Server. 8. On the computer where EasyMatch QC will be run, open EasyMatch QC. 9. Select SYSTEM CONFIGURATION > OPTIONS, and then DATA STORAGE. The Data Storage Screen appears. 10. Select the SQL SERVER, enter the server and database name (EZMQC). Click OK. 154 EasyMatch QC User’s Manual Version 3.8 Figure 255. SQL Database Storage When the SQL Database Server is selected, a new option is provided to select the Authentication type as Windows or SQL server in the Data Storage Dialog. If Windows is selected, the current system login in user credentials will be used to login to the SQL server, then there is no need to specify the user name and password. When SQL Server option is selected, the database server credentials need to be specified. Note: When Windows Authentication option is selected in SQL server (local server or network server in a domain), the login security permissions should be added for the configured EZMQC-ER Admin/User groups for EZMQC database in the SQL Server. 11. Restart EasyMatch QC and then SQL Server Database is ready for use. 12. A separate data table is created for each instrument based on the sensor name. The following information is available in this table: time stamp, measurement type, measurement name, color scale, Ill/Obs, tristimulus color value, sensor type, sensor ID and spectral data. This table can be imported directly to the user’s own SQL server. An example of this table is shown below. 155 EasyMatch QC User’s Manual Version 3.8 Figure 256. Additional Table for Each Sensor 156 EasyMatch QC User’s Manual Version 3.8 157 EasyMatch QC User’s Manual Version 3.8 Figures Figure 1. EasyMatch Installation ............................................................................................................... 12 Figure 2. Installation for Flash Drive ......................................................................................................... 12 Figure 3. Software Key License ................................................................................................................. 12 Figure 4. Completed Install ....................................................................................................................... 13 Figure 5. No License Warning ................................................................................................................... 13 Figure 6. Activate License ......................................................................................................................... 14 Figure 7. Request 30-day Trial .................................................................................................................. 15 Figure 8. Sensor Manager ......................................................................................................................... 15 Figure 9. Setup Sensor .............................................................................................................................. 15 Figure 10. Setup Mode.............................................................................................................................. 16 Figure 11. LabScan Standardization .......................................................................................................... 18 Figure 12. Standardizing on the Light Trap to set Bottom-of-Scale ......................................................... 18 Figure 13. Setting Bottom-of-Scale for RTRAN ......................................................................................... 19 Figure 14. Setting Bottom-of-scale for RTRAN Mode ............................................................................... 19 Figure 15. Setting Top-of-Scale with the White Tile ................................................................................. 19 Figure 16. Parts of a Job ............................................................................................................................ 23 Figure 17. Example of a Template ............................................................................................................ 25 Figure 18. Job Tree .................................................................................................................................... 27 Figure 19. Properties of a Standard .......................................................................................................... 28 Figure 20. Tolerances ................................................................................................................................ 28 Figure 21. Hitch Standardization .............................................................................................................. 28 Figure 22. Setting Up a Hitch Standard ..................................................................................................... 29 Figure 23. Print Preview ............................................................................................................................ 29 Figure 24. Printing the Job Tree ................................................................................................................ 30 Figure 25. Enter Colorimetric Data for a Standard ................................................................................... 30 Figure 26. Entering Standard ID ................................................................................................................ 31 Figure 27. Entering Spectral Data for a Standard ..................................................................................... 31 Figure 28. Entering Sample ID................................................................................................................... 31 Figure 29. Color Data Table....................................................................................................................... 32 Figure 30. Configure the Color Data Table ............................................................................................... 32 Figure 31. Configure Custom Field ............................................................................................................ 33 Figure 32. Select a Custom Label .............................................................................................................. 33 Figure 33. Custom Field Added to Color Data Table ................................................................................. 34 Figure 34. Inserting Data for Custom Field ............................................................................................... 34 Figure 35. Display of Data for Custom Field ............................................................................................. 34 Figure 36. Custom Field Configuration ..................................................................................................... 34 Figure 37. Label for Formula Field ............................................................................................................ 35 Figure 38. Enter Custom Formula ............................................................................................................. 35 Figure 39.Measurements with Text Criteria ............................................................................................. 35 Figure 40. Display of Custom Formula in the Field ................................................................................... 36 Figure 41. Color Data Table with Custom Fields ....................................................................................... 37 Figure 42. Print Preview of Color Data Table ............................................................................................ 37 Figure 43. Printed View of Color Data Table (Truncated page) ................................................................ 38 Figure 44. 2D Color Plot ............................................................................................................................ 39 158 EasyMatch QC User’s Manual Version 3.8 Figure 45. 2D Color Plot Configuration ..................................................................................................... 39 Figure 46. Print Preview of 2D Color Plot ................................................................................................. 40 Figure 47. Printed Output of 2D Color Plot............................................................................................... 41 Figure 48. 3D Color Plot ............................................................................................................................ 42 Figure 49. 3D Color Plot Configuration ..................................................................................................... 42 Figure 50. Print Preview of 3D Color Plot ................................................................................................. 43 Figure 51. Printer Output of 3D Color Plot ............................................................................................... 43 Figure 52. Color Rendering Plot ................................................................................................................ 44 Figure 53. Color Rendering Configuration ................................................................................................ 45 Figure 54. Color Rendering Print Preview ................................................................................................. 45 Figure 55. Color Rendering Printer Output ............................................................................................... 46 Figure 56. Easy View Screen ..................................................................................................................... 47 Figure 57. EZ View Configuration .............................................................................................................. 47 Figure 58. EZ View Print Preview .............................................................................................................. 48 Figure 59. EZ View Printer Output ............................................................................................................ 48 Figure 60. Memo View .............................................................................................................................. 49 Figure 61. Memo View Configuration ....................................................................................................... 50 Figure 62. Memo View Print Preview ....................................................................................................... 50 Figure 63. Memo View Printer Output ..................................................................................................... 51 Figure 64. Spectral Data View ................................................................................................................... 51 Figure 65. Spectral Data Configuration ..................................................................................................... 52 Figure 66. Spectral Data Print Preview ..................................................................................................... 52 Figure 67. Spectral Data Printer Output ................................................................................................... 53 Figure 68. Spectral Plot View .................................................................................................................... 54 Figure 69. Spectral Plot Configuration ...................................................................................................... 54 Figure 70. Spectral Plot Print Preview ...................................................................................................... 55 Figure 71. Spectral Plot Printer Output .................................................................................................... 55 Figure 72. Trend Plot View – Line and Point ............................................................................................. 56 Figure 73. Trend Plot Configuration ......................................................................................................... 57 Figure 74. Trend Plot Limits ...................................................................................................................... 57 Figure 75. Trend Plot Print Preview .......................................................................................................... 58 Figure 76. Trend Plot Printout .................................................................................................................. 58 Figure 77. Database Title .......................................................................................................................... 59 Figure 78. Keyboard Shortcuts .................................................................................................................. 60 Figure 79. Open Commands ..................................................................................................................... 61 Figure 80. Command from Open File Menu ............................................................................................. 61 Figure 81. Open Edit Menu ....................................................................................................................... 62 Figure 82.Open View Menu ...................................................................................................................... 62 Figure 83. Open Measurements ............................................................................................................... 62 Figure 84. Open Options ........................................................................................................................... 62 Figure 85. Open Sensor ............................................................................................................................. 63 Figure 86. Open Window .......................................................................................................................... 63 Figure 87. Open Help ................................................................................................................................ 63 Figure 88. Open Job Menu ........................................................................................................................ 65 Figure 89. Job Template: Open ................................................................................................................. 66 Figure 90. Recall Measurement ................................................................................................................ 66 159 EasyMatch QC User’s Manual Version 3.8 Figure 91. Recall Measurement based on dE ........................................................................................... 67 Figure 92. Search Criteria for dE ............................................................................................................... 67 Figure 93. Search Results .......................................................................................................................... 68 Figure 94. Search Using Query .................................................................................................................. 68 Figure 95. List of Queries .......................................................................................................................... 69 Figure 96. Delete from Database .............................................................................................................. 70 Figure 97. Criteria for Deletion ................................................................................................................. 70 Figure 98. Delete based on dE .................................................................................................................. 70 Figure 99. Search Criteria for Deletion ..................................................................................................... 71 Figure 100. Search Results for Deletion .................................................................................................... 71 Figure 101. File Save As............................................................................................................................. 72 Figure 102. Job Save As ............................................................................................................................. 72 Figure 103. Measurements Saved ............................................................................................................ 73 Figure 104. eSignature .............................................................................................................................. 73 Figure 105. Company Logo Configuration ................................................................................................ 74 Figure 106. Select Company Logo ............................................................................................................. 74 Figure 107. Report Header & Footer ........................................................................................................ 74 Figure 108. Print Job Setup ....................................................................................................................... 75 Figure 109. Selected Views to Print .......................................................................................................... 76 Figure 110. Printing Spectral Data Table .................................................................................................. 76 Figure 111. Print Job Preview ................................................................................................................... 77 Figure 112. Printer Setup .......................................................................................................................... 77 Figure 113. Printer Margins ...................................................................................................................... 78 Figure 114. Import File into Current Job ................................................................................................... 78 Figure 115. QTX Format ............................................................................................................................ 79 Figure 116. Email Command ..................................................................................................................... 79 Figure 117. Database Backup.................................................................................................................... 80 Figure 118. Database Import .................................................................................................................... 80 Figure 119. Import Measurement ............................................................................................................ 81 Figure 120. Import Dialog Box .................................................................................................................. 81 Figure 121. Import Completed.................................................................................................................. 81 Figure 122. Save New Database ............................................................................................................... 82 Figure 123. Import Database .................................................................................................................... 82 Figure 124. Results of Searching a Database ............................................................................................ 82 Figure 125. Import File to . . . .................................................................................................................... 83 Figure 126. Log Off for User ...................................................................................................................... 83 Figure 127. Confirming Deletion ............................................................................................................... 85 Figure 128. Display of Toolbar .................................................................................................................. 87 Figure 129. Toolbar Not Displayed ........................................................................................................... 87 Figure 130. Status Bar is Displayed ........................................................................................................... 88 Figure 131. No Status Bar Displayed ......................................................................................................... 88 Figure 132. Job Tree is Displayed .............................................................................................................. 89 Figure 133. Job Tree Not Displayed .......................................................................................................... 89 Figure 134. View Audit Log ....................................................................................................................... 90 Figure 135. Printout of Audit Log .............................................................................................................. 90 Figure 136. Event Log Filters ..................................................................................................................... 91 160 EasyMatch QC User’s Manual Version 3.8 Figure 137. Event Log Configuration......................................................................................................... 91 Figure 138. Event List ................................................................................................................................ 91 Figure 139. Event Details .......................................................................................................................... 92 Figure 140. Enter Standard ID ................................................................................................................... 93 Figure 141. Enter Sample ID ..................................................................................................................... 93 Figure 142. Name the Series ..................................................................................................................... 94 Figure 143. Configure Color Data Table .................................................................................................... 95 Figure 144. Right Click to Select Standard Properties .............................................................................. 95 Figure 145. Select Tolerances ................................................................................................................... 96 Figure 146. Input Tolerance Limits ........................................................................................................... 96 Figure 147. Configure Color Plot ............................................................................................................... 96 Figure 148. Graphical Display of Chromaticity Plot .................................................................................. 97 Figure 149. Measurement Average .......................................................................................................... 97 Figure 150. Calculating Measurement Average........................................................................................ 98 Figure 151. Search Results for Best Standard Fit ...................................................................................... 98 Figure 152. Standard to Compare Average .............................................................................................. 99 Figure 153. Calculated Measurement Average ........................................................................................ 99 Figure 154. Measurement Average Saved as Standard ............................................................................ 99 Figure 155. Setting Up Naming Rules ..................................................................................................... 101 Figure 156. Rules for Naming Standards ................................................................................................ 102 Figure 157. Rules for Naming Series ....................................................................................................... 102 Figure 158. Rules for Naming Products .................................................................................................. 103 Figure 159. Extra ID Rules ....................................................................................................................... 103 Figure 160. Selecting a Method for Averaging ....................................................................................... 104 Figure 161. Selecting Special Read Method............................................................................................ 105 Figure 162. Read Method Menu: Opacity .............................................................................................. 105 Figure 163. Read Method Menu: Haze ................................................................................................... 106 Figure 164. Multimode Read Option ...................................................................................................... 106 Figure 165. Timed Readings .................................................................................................................... 107 Figure 166. Automatic Standard Search ................................................................................................. 107 Figure 167. Setting Tolerances................................................................................................................ 108 Figure 168. Setting Tolerances for an Index ........................................................................................... 108 Figure 169. Setting Tolerances for a Difference ..................................................................................... 109 Figure 170. Setting Shade Tolerances ..................................................................................................... 109 Figure 171. Setting Haze & Opacity Tolerances ...................................................................................... 110 Figure 172. Select Adjustable Scale ........................................................................................................ 110 Figure 173. Enter CMC Factors ............................................................................................................... 111 Figure 174. Export ASCII .......................................................................................................................... 111 Figure 175. ASCII Export Configuration................................................................................................... 111 Figure 176. ASCII Export to Notepad ...................................................................................................... 112 Figure 177. Data Send COM Port Selection ............................................................................................ 113 Figure 178. Data Send Configuration ...................................................................................................... 113 Figure 179. Data Send COM Port Configuration ..................................................................................... 114 Figure 180. Select Custom Index............................................................................................................. 114 Figure 181. Select New Custom Index for CDT Screen ........................................................................... 115 Figure 182. Global Preferences Menu .................................................................................................... 115 161 EasyMatch QC User’s Manual Version 3.8 Figure 183. Global Preferences for Illuminants ...................................................................................... 116 Figure 184. Global Preferences for Language ......................................................................................... 116 Figure 185. Global Preferences - Default Job Template ......................................................................... 116 Figure 186. Global Preferences - Open Job Template ............................................................................ 117 Figure 187. Global Preferences - Browse for Job File ............................................................................. 117 Figure 188. Global Template - Sample ID ............................................................................................... 118 Figure 189. Global Preferences Current Sensor & Standardization Mode Options ............................... 118 Figure 190. External Trigger Configuration ............................................................................................. 119 Figure 191. Standardization Using External Trigger ............................................................................... 120 Figure 192. Standard Measurement by External Trigger ....................................................................... 120 Figure 193. User Manager ...................................................................................................................... 122 Figure 194. User Manager: New User..................................................................................................... 122 Figure 195. User Manager: Set Password .............................................................................................. 122 Figure 196. User Manager: Edit User Name .......................................................................................... 123 Figure 197. User Manager: Select Group ............................................................................................... 123 Figure 198. User Manager: View Groups ............................................................................................... 123 Figure 199. User Manager: Add New Group.......................................................................................... 124 Figure 200. Add New Group Privileges ................................................................................................... 124 Figure 201. User Manager: Add Users ................................................................................................... 125 Figure 202. Default Storage Location ..................................................................................................... 126 Figure 203. ER Version: Server Settings ................................................................................................. 126 Figure 204. Defining the Toolbar ............................................................................................................ 127 Figure 205. Sensor Manager ................................................................................................................... 129 Figure 206. Configuring Sensor Type & ID .............................................................................................. 129 Figure 207. Setup Mode for Sensor ........................................................................................................ 130 Figure 208. Sensor Deletion .................................................................................................................... 130 Figure 209. Renaming a Sensor .............................................................................................................. 130 Figure 210. Set Modes for a Sensor ........................................................................................................ 131 Figure 211. Standardization: Bottom of Scale ........................................................................................ 131 Figure 212. Standardization: Top-of-scale .............................................................................................. 132 Figure 213. Confirming that Standardization is Completed ................................................................... 132 Figure 214. Set Modes for a Sensor ........................................................................................................ 133 Figure 215. Restandardization Interval ................................................................................................... 133 Figure 216. Secondary Standardization for LabScan XE ......................................................................... 133 Figure 217. Calibration of UV Filter: 457 Brightness .............................................................................. 134 Figure 218. Calibration of WI GANZ ........................................................................................................ 134 Figure 219. Prompt for Calibration of UV Filter ...................................................................................... 134 Figure 220. Multimode Configuration .................................................................................................... 135 Figure 221. Multimode: Mode Selection ............................................................................................... 135 Figure 222. Data log: Import Readings .................................................................................................. 136 Figure 223. Data log: Available Data ....................................................................................................... 136 Figure 224. Configure Setups: Groups .................................................................................................... 137 Figure 225. Product Setup by Instrument: ColorFlex EZ (left), MiniScan EZ (right) ............................... 138 Figure 226. Green Tile Test ..................................................................................................................... 139 Figure 227. Reminder to Install Standard Port Plate .............................................................................. 139 Figure 228. Prompt to Read the Green Tile ............................................................................................ 139 162 EasyMatch QC User’s Manual Version 3.8 Figure 229. Results of Diagnostics: Green Tile........................................................................................ 140 Figure 230. Diagnostics Report ............................................................................................................... 140 Figure 231. Reminder to Use Standard Port Plate .................................................................................. 140 Figure 232. Repeatability Test: White Tile .............................................................................................. 141 Figure 233. Repeatability Test: White Tile Readings ............................................................................. 141 Figure 234. Report on Repeatability Test ............................................................................................... 142 Figure 235. Didymium Filter Test: Reminder to Use Standard Port Plate .............................................. 142 Figure 236. Didymium Filter Test: Place filter at RTRAN port ................................................................ 143 Figure 237. Inserting the Didymium Filter at RTRAN port (lens side) .................................................... 143 Figure 238. Didymium Filter Test: Enter Data Sheet Values .................................................................. 143 Figure 239. Display of Didymium Filter Readings & Average ................................................................. 144 Figure 240. Reminder to Remove the Didymium Filter .......................................................................... 144 Figure 241. Report on Didymium Filter Readings ................................................................................... 145 Figure 242. Instrument Status Information ............................................................................................ 145 Figure 243. Advanced Diagnostics: Read Photometric Data ................................................................. 146 Figure 244. Advanced Diagnostics: Standardize .................................................................................... 146 Figure 245. Advanced Diagnostics: Motor Test ..................................................................................... 146 Figure 246. Advanced Diagnostics: Signal Level Test ............................................................................. 146 Figure 247. Predictive Diagnostics Settings ........................................................................................... 147 Figure 248. Green Tile Diagnostic Trend................................................................................................. 147 Figure 249. Creating a New Window ...................................................................................................... 148 Figure 250. Cascading of Windows ......................................................................................................... 148 Figure 251. Window Tile for Multiple Windows ..................................................................................... 149 Figure 252. Help Menu: About ............................................................................................................... 150 Figure 253. License Information ............................................................................................................. 151 Figure 254. Creating an SQL Database .................................................................................................... 154 Figure 255. SQL Database Storage .......................................................................................................... 155 Figure 256. Additional Table for Each Sensor ......................................................................................... 156 163 EasyMatch QC User’s Manual Version 3.8 Index 2D Color plot, 38 3D Color plot, 42 About, 151 Adjust Scale Factors, 110 Advanced Diagnostics, 145 An error occurred during the move data process, 153 Application Preferences, 115 Apply Template to Job, 73 ASCII export, 111 Audit Log, 90 Automatic Standard Search, 98 Average, 97 Average method, 104 Average Selected to Measurement, 99 Average Selected to New Standard, 99 Average selected to standard, 99 Backup Database, 80 Cannot execute the application due to Invalid license., 153 Cascade, 149 Close Job, 71 Color data table, 31 Color render, 44 Company Logo, 73 Configure Automatic Standard Search, 107 Configure Multi Mode, 135 Configure setups, 137 Configure Timed Read, 107 Copy, 85 Create New Database, 81 Custom Data Field, 33 Custom Field, 33 Custom Formula Field, 34 Customize Toolbar, 127 Cut, 85 Data Send, 112 Data Storage, 125 Data views, 26 Database, 80 Default tolerances, 108 Delete, 85 Delete Measurement from Database, 69 Diagnostics, 138 164 Didymium Filter Test, 142 Difference tolerances, 109 EasyGroup, 127 Edit menu, 85 Copy, 85 Cut, 85 Delete, 85 Paste, 85 E-mail, 79 error message, 153 eSignature, 73 Event Log, 90 Exit, 83 Export, 78 EZ view, 46 Features of software, 23 File menu, 65 Apply template to job, 73 Close job, 71 Configure company logo, 73 Delete measurement from database, 69 E-mail, 79 Exit, 83 Export, 78 Header/footer setup, 74 Import QTX format, 78 Log off, 83 Most recently opened jobs, 83 New Job, 65 Open job, 65 Open job template, 65 Page setup, 78 Print job, 77 Print job preview, 76 Print job setup, 75 Printer setup, 77 Recall measurement from database, 66 Save job, 72 Save job as, 72 Save job template, 72 Save job template as, 72 Save measurement to database, 73 Signature, 73 Green Tile Test, 138 EasyMatch QC User’s Manual Version 3.8 Haze, 105 Haze tolerances, 110 Header/footer setup, 75 Help menu, 151 About, 151 Help topics, 151 HunterLab on the web, 151 Help topics, 151 Highway Safety Colors (ASTM 4956, 94 HunterLab on the Web, 151 Import EasyGroup Sequence, 127 Import Logged Reads, 136 Import Textiles Database, 82 Index tolerances, 108 Insert Custom Field, 33 Install the software, 11 Install/Configure, 129 Job conventions, 24 Job tree, 26 Job Tree, 89 Jobs, 23 Keep Sample Measurement Window Open, 117 Lock sensor to Job, 118 Lock Standardization mode to Job, 118 Log Off, 83 Measurements menu, 93 Automatic standard search, 98 Average, 97 Average selected to measurement, 99 Average selected to new standard, 99 Average selected to standard, 99 Read sample, 93 Read series, 94 Read standard, 93 Timed read, 98 Memo view, 49 Most Recently Opened Jobs, 83 Multiple Read Mode, 106 Naming conventions, 101 New Job, 65 New window, 149 Opacity, 105 Opacity tolerances, 110 Open job template, 65 Open Jobs, 150 Options menu, 101 Adjust scale factors, 110 Application Preferences, 115 ASCII export, 111 Average method, 104 Customize toolbar, 127 Data send, 112 Default tolerances, 107 EasyGroup, 127 Import EasyGroup Sequence, 127 Naming conventions, 101 Read Method, 105 System configuration, 121 Options Menu Configure automatic standard search, 107 Configure timed read, 107 Page Setup, 78 Paste, 85 Print Job, 77 Print Job Preview, 76 Print Job Setup, 75 Printer Setup, 77 QTX, 78 QTX Format, 78 Read method, 105 Read sample, 93 Read Series, 94 Read standard, 93 Recall Measurement from Database, 66 Repeatability Test, 140 Retain IDs in Sample Measurement Window, 118 Safety notes, 2 Save job, 72 Save job as, 72 Save job template, 72 Save Job Template As, 72 Save Measurement to Database, 73 Scale tolerances, 108 Sensor Installation, 15 Sensor menu Diagnostics, 138 Sensors menu, 129 Configure Multi Mode, 135 Configure setups, 137 Install/Configure, 129 Set interval, 133 165 EasyMatch QC User’s Manual Version 3.8 Set Modes, 132 Standardize, 131 UV filter calibration, 133 Sensors Menu Import logged reads, 136 Server settings, 126 Set interval, 133 Set Modes, 132 Shade tolerances, 109 SoftKey License Activation, 13 Software Installation, 11 Software messages, 153 Spectral data table, 51 Spectral plot, 54, 59 Standardization, 17 45/0 or 0/45, 17 Standardization d/8 sphere, 18 Standardize, 131 Status bar, 88 System configuration, 121 Templates, 25 166 Tile, 150 Time synchronization, 80 Timed Read, 98 Toolbar, 87 Toolbar buttons, 24 Trend plot, 56 Universal Database Import, 81 User Manager, 121 UV Filter Calibration, 133 View menu, 87 Audit log, 90 Event log, 90 Job tree, 89 Status bar, 88 Toolbar, 87 Window menu, 149 Cascade, 149 New window, 149 Open jobs, 150 Tile, 150 Yxy Chromaticity Plot, 94 ">
/
Descargar
Solo un recordatorio amistoso. Puedes ver el documento aquí mismo. Pero lo más importante es que nuestra IA ya lo ha leído. Puede explicar cosas complejas en términos sencillos, responder a tus preguntas en cualquier idioma y ayudarte a navegar rápidamente incluso por los documentos más largos o complicados.
Anuncio