U-Line VCDE215-SSH1A 15" 2 Tap Cold Coffee Dispenser User Guide & Service Manual
Below you will find brief information for VCDE215-SSH1A. This dispenser features an internal nitrogen source or allows connection to an external source to deliver the perfect nitro cold brew. Discover installation steps, operating instructions, cleaning, maintenance, and troubleshooting for your dispenser. It is designed for both free-standing and built-in applications. Also, it provides safety warnings, disposal instructions, and maintenance guide.
Advertisement
Advertisement
USER GUIDE & SERVICE MANUAL ® Model: VCDE215-SSH1A USER GUIDE & SERVICE MANUAL Click on any section below to jump directly there Table of Contents Intro R600a Specifications System Diagnosis Guide Safety Compressor Specifications Safety and Warning Disposal And Recycling Installation Environmental Requirements Electrical Cutout & Product Dimensions Anti-Tip Bracket General Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non-Use Operating Instructions First Use Control Operation Airflow and Product Loading Service Troubleshooting Wire Diagram Product Liability Parts Troubleshooting Extended Control Operation - Service Thermistor Defrost Remove Fan and Cover Warranty USER GUIDE WELCOME TO VIKING COMMERCIAL Congratulations on your purchase! Viking is synonymous with decades of innovation and craftsmanship. Our industry-leading appliances set the standards. Delivering professional performance and stunning design. Our products have become the standard for elite chefs around the world. PRODUCT INFORMATION Looking for additional information on your product? User Guides, Spec Sheets, and Product Warranty information are available online at vikingrange.com/commercial. PROPERTY DAMAGE / INDUSTRY CONCERNS In the unlikely event property damage or personal injury is suspected related to a Viking Commercial product, please take the following steps: 1. Customer Care must be contacted at +1.616.754.5601 2. Service or repairs performed on the unit without prior written approval is not permitted. If the units have been altered or repaired in the field without prior written approval, claims will not be eligible. GENERAL INQUIRIES SERVICE & PARTS ASSISTANCE 1260 E. Van Deinse • Greenville, MI 48838 • Monday – Friday 8:00 am to 4:30 pm CST +1.616.754.5601 +1.616.754.5601 Website: vikingrange.com/commercial Service Email: [email protected] [email protected] CONNECT WITH US Introduction 3 USER GUIDE Safety and Warning This appliance is not intended for use by persons NOTICE mental capabilities, or lack of experience or knowledge, Please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide: (including children) with reduced physical, sensory or unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with this appliance. ! DANGER SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger, Warning, or Caution based on the risk type: ! DANGER Danger means that failure to follow this safety statement will result in severe personal injury or This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the “R600a specifications” section included in the User Guide. Do not damage the refrigerant circuit. death. ! WARNING ! WARNING Service must be done by factory authorized service personnel. Any parts shall be replaced Warning means that failure to follow this safety statement could result in serious personal injury or death. ! CAUTION with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service. CALIFORNIA PROPOSITION 65 Caution means that failure to follow this safety This product contains chemicals known to the statement may result in minor or moderate state of California to cause cancer and birth personal injury, property, or equipment damage. defects or other reproductive harm. www.P65warnings.CA.gov Caution: risk of fire, flammable refrigerant and ! CAUTION blowing gas used. GENERAL PRECAUTIONS Use this appliance for its intended purpose only and follow This equipment is to be installed with adequate backflow protection to comply with applicable federal, state and local codes. these general precautions with those listed throughout this guide. Safety and Warning 4 USER GUIDE ! WARNING Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. ! WARNING DO NOT use medical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer. DO Please accord to local regulations regarding NOT use an ice pick or other sharp instrument to disposal of the appliance for its flammable help speed up defrosting. These instruments can refrigerant and blowing gas. Before you scrap the puncture the inner lining or damage the cooling appliance, please remove the doors to prevent unit. DO NOT use any type of heater to defrost. child entrapment. Using a heater to speed up defrosting can cause Do not store explosive substances such as personal injury and damage to the inner lining. aerosol cans with a flammable propellant in this appliance. ! WARNING Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. ! WARNING Do not damage the refrigerating circuit. This warning is only applicable for appliances with refrigerating circuits which are accessible by the user. ! WARNING Do not use electrical appliances inside the food/ NOTICE Do not lift unit by door handle. Never install or operate the unit behind closed doors. Be sure front grille is free of obstruction. Obstructing free airflow can cause the unit to malfunction and will void the warranty. Failure to clean the condenser every six months can cause the unit to malfunction. This could void the warranty. Allow unit temperature to stabilize for 24 hours before use. Do not block any internal fans. Use only genuine U-Line replacement parts. Imitation parts can damage the unit, affect its operation or performance and may void the warranty. ice storage compartments unless they are of the This appliance is intended to be used in household and type recommended by the manufacturer. similar applications such as: • Staff kitchen areas in shops, offices and other working environments. • Farm houses and by clients in hotels, motels and other residential type environments. • Bed and breakfast type environments. • Catering and similar non-retail applications. ! WARNING When positioning the appliance, ensure the supply cord is not trapped or damaged. ! WARNING Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance. Safety and Warning 5 USER GUIDE Disposal and Recycling ! DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely: 1. Remove all consumable contents from the unit. 2. Unplug the electrical cord from its socket. 3. Remove the door(s)/drawer(s). Disposal and Recycling 6 USER GUIDE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 90°F (32°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. For best performance, keep the unit out of direct sunlight and away from heat generating equipment. In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops. ! CAUTION Damages caused by ambient temperatures of 40°F (4°C) or below are not covered by the warranty. CLIMATE CLASSES Test room climate class Dry bulb temperature Relative humidity Dew point Water vapor mass in dry air 0C % 0C g/kg 0 20 50 9.3 7.3 1 16 80 12.6 9.1 2 22 65 15.2 10.8 3 25 60 16.7 12.0 4 30 55 20.0 14.8 6 27 70 21.1 15.8 5 40 40 23.9 18.8 7 35 75 30.0 27.3 8 23.9 55 14.3 10.2 NOTE: The water vapor mass in dry air is one of the main points influencing the performance and the energy consumption of the cabinets. Environmental Requirements 7 USER GUIDE Electrical ! WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty. Never use an extension cord to connect power to the unit. Always keep your working area dry. NOTICE Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician. The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. A GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping. However, be sure to consult your local codes. See CUTOUT & PRODUCT DIMENSIONS for recommended receptacle location. Electrical 8 USER GUIDE 50 1⁄16” (1,272 mm) Cutout & Product Dimensions 45 13⁄16” (1,165 mm) PREPARE SITE Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit FRONT does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, and clearance is required for an electrical connection in the rear. 28” (711 mm) 34 ½” (876 mm) to 35 ½” (902 mm) ! CAUTION Unit can NOT be installed behind a closed cabinet door. 3 11⁄16” (95 mm) 15” (381 mm) CUTOUT DIMENSIONS 11” (279 mm) TOP 2 3/4” (57 mm) 24 ¼” (616 mm) Preferred location for electrical outlet is in adjacent cabinet. 34 3⁄4" (883 mm) to 35 3⁄4" (909 mm) 14 ¼” (362 mm) 28" (712 mm) 5⁄8" (16 mm) 7" (178 mm) 7 ½” (191 mm) 1 7⁄8” (48 mm) 15 9⁄16” (396 mm) 4" (102 mm) 15 1⁄4" (388 mm) PRODUCT DIMENSIONS 27 13⁄16” (708 mm) REAR 25 15⁄16” (660 mm) SIDE 1” (25 mm) 25 ½” (648 mm) 6” (152 mm) 19 15⁄16” (507 mm) Power Cord 2 ¾” (70 mm) Cutout & Product Dimensions Power Cord 7 7⁄16” (189 mm) 2” (51 mm) 1 “ (25 mm) 9 USER GUIDE Anti-Tip Bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Tighten screws fully. 4. Gently push unit into position. Be careful not to entangle the electrical cord or water line, if applicable. 5. Check to be sure the unit is level from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1⁄8” (3 mm) below the countertop. 6. Secure bracket into adjoining surface. Anti-Tip Bracket 10 USER GUIDE General Installation The following components are shipped inside the unit: 1. Double Tower (faucets, handles, gaskets, & hardware) 2. Nitrogen hose (1 hose clamp) 3. Infuser regulator (hoses & hardware) 4. Liquid jumper line (with in-line filter) and gas jumper line 5. Drip tray 6. Cleaning solution (2-ounce packet) (Additional cleaner, ULACOFFEECLEAN, is available at u-line.com) 7. Four casters (2 locking, 2 non-locking) 4 2 7 6 1 3 5 Required (not included): 1. Food grade nitrogen - available at your local gas supplier. 22 cubic feet aluminum empty tank (ULANITROTANK) and nitrogen regulator (ULANITROREG) are available at u-line.com. Note: If using an external nitrogen source, see CONNECTING EXTERNAL NITROGEN SOURCE section. 2. Ball-tap keg - up to 5 gallon 3. Your favorite cold coffe or tea. General Installation Safety and Warning ! WARNING Keep nitrogen tank in an upright position and handle with care. Never exceed 60 PSI. Ventilate area after nitrogen leak. 11 USER GUIDE Install Tower on Free-Standing Refrigerator Do not remove all the protective film on the stainless exterior until the tower is installed. 1. Remove four Phillips screws (secured with nuts on the inside of the refrigerator) and lift off cap to reveal tower mounting hole. Peel back enough film for tower to clear. 2. Position gasket over mounting hole and install tower using four Phillips screws and nuts. 3. Gasket General Installation 12 Screw the handles onto the faucets and continue to assemble and connect regulator to Nitrogen tank. USER GUIDE Install Tower on Countertop (See template on next page) Note: These instructions are designed for a standard 36" countertop application. Note: For a customized fit, it may be necessary to acquire screws that are sized to the thickness of your countertop. 1. Position keg refrigerator under countertop to determine the desired depth. 2. Use the dimensions from Diagram A to determine the center point of the tower mounting hole. 3. Remove keg refrigerator from under countertop. 4. Use template to drill 4 mounting holes and drill 3-1⁄8" diameter hole through countertop. 5. Connect keg and infuser hoses to tower. 6. Pull down insulation inside tower far enough to extend into refrigerator - Diagram B. 7. Secure tower to countertop. 8. Remove hole cover from top of refrigerator. 9. Carefully slide refrigerator under countertop, taking care to insert hoses and insullation as you go. Diagram A 6 Diagram B Rear Wall 15” (381 mm) 2” (51 mm) Front edge of hole to front face of refrigerator 11-1/8” (283 mm) Power Cord Countertop Rear Wall 24 ¼” (616 mm) 7 ½” (19 1 mm) Insulation 2 ¾” (70 mm) Hole Diameter 12 ½” (318 mm) 11 1⁄8” (283 mm) 1 11⁄16” (43 mm) General Installation Front Face of Unit 13 USER GUIDE Template for Countertop Installation Note: Verify template has printed true to scale - double check hole dimensions and placement. 1 Inch 7-1/2“ TO SIDE OF REFRIGERATOR 1⁄4” HOLE 2-3/4“ HOLE 12-1/2“ TO FRONT FACE OF REFRIGERATOR (SEE DIAGRAM A PREVIOUS PAGE) General Installation 14 USER GUIDE Connecting Internal Nitrogen Source 3. Attach nitrogen hose to ball valve on tank regulator. Make sure valve is in the off position - turned clockwise as far as it can go. Tighten hose clamp. 4. Attach other end of nitrogen hose to T connector on infuser regulator - line up and press in firmly. Install Infuser Regulator 1. Tower Align infuser regulator withTo Tap pre-drilled holes in upper left corner of side wall. Use 2 screws to attach. Interior Side Wall 6 5 4 3 2 1 7 8 9 10 11 12 13 15 14 Assemble and connect tank regulator to tank 1. Attach ball valve to tank regulator (not included). Tighten with an adjustable wrench. Make sure valve is in the off position - turned clockwise as far as it can go. T-Connector 2. Attach regulator to nitrogen tank. Hand tighten the coupling nut and then use an adjustable wrench for an additional quarter turn. DO NOT OVER TIGHTEN. Connect nitrogen to keg 1. Attach gas jumper line to T connector on infuser regulator - line up and press in firmly. T-Connector General Installation 15 USER GUIDE 2. Attach gray coupler of the gas jumper line to keg. With your thumb press down on the top of the coupler while pulling up on collar. Press coupler down firmly onto "in" valve. Release collar - listen for a click. Pull up on the coupler to ensure it is locked down. Connect keg to tower 1. In Valve Attach black nitrogen coupler of the liquid jumper line to keg. With your thumb press down on the top of the coupler while pulling up on collar. Press coupler down firmly onto "out" valve. Release collar - listen for a click. Pull up on the coupler to ensure it is locked down. Out Valve 3. Attach infuser hose to elbow connector on infuser regulator. 2. Attach other end of beverage hose to "Y" connection within dispenser tower - line up and press in firmly. Other end is connected to keg Other end is connected to Tower Elbow Connector 4. Attach other end of hose to the single connection within the beverage tower. Other end is connected to Infuser Regulator General Installation 16 USER GUIDE Connecting External Nitrogen Source 4. Insert gasket ring into hole that corresponds to the drilled-out hole in bulkhead. 5. Inside cabinet, apply foodgrade lubricant to inside of gasket ring in bulkhead and push nitrogen hose through. Note: Connection to an external Nitrogen source requires drilling one hole through the preinstalled bulkhead located near the top of the back wall. Install Infuser Regulator 1. Align infuser regulator with pre-drilled holes in upper To Tap Tower left corner of side wall. Use 2 screws to attach. Interior Side Wall Connects to keg Inside 6 5 4 3 2 1 7 8 9 10 11 12 13 15 14 6. Prepare bulkhead and back panel 1. Attach nitrogen hose to infuser regulator T-Connector Inside the cabinet, drill out 1 of the ⁹⁄16" holes in the bulkhead. 7. At the back of the unit, appy foodgrade lubricant to inside of gasket ring and push nitrogen hose through. 8. Re-install back panel. Outside 2. Insert gasket ring into drilled-out hole. Connects to external nitrogen 9. Connect nitrogen hose to external nitrogen source. 10. Continue with inside connections (see CONNECT NITROGREN TO KEG in this manual) 3. In the back of the unit, remove back panel. General Installation 17 USER GUIDE Connections When complete, the connections should look like this: Infuser Regulator Keg Filter Assembly LEVELING INFORMATION 1. ! CAUTION Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. To comply with applicable federal, state, and local codes, it may be necessary to caulk the refrigerator to the floor. CASTERS (optional) 2. 3. If the unit is not level, shim as needed. Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level. 1. Remove grille and back panel to access nuts. 2. Remove each nut and unscrew each leg. 3. Install each caster and secure with nut. Tighten with included wrench. 4. Replace grille and back panel. When ready to use, see FIRST USE section in this manual. General Installation 18 USER GUIDE Grille Installation REMOVING AND INSTALLING GRILLE ! WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille Note: Grille and display are attached. The length of the display wire is sufficient to allow access to the front base components. 1. Disconnect power to the unit. 2. Loosen the two screws (1). 3. Remove grille (2) from unit. Installing the grille 1. Align cabinet and grille holes and secure, but do not over tighten grille screws (1). 2. Reconnect power to the unit. 1 2 Grille Installation 19 USER GUIDE Door Swing 3 1⁄8” (79 mm) Minimum Clearance Needed 900 Door Swing Stainless steel models require 3 1⁄8” (79 mm) door clearance to accommodate the handle if installed next to a wall. Door Swing 20 USER GUIDE Door Adjustments TO REVERSE THE DOOR HINGE COVER Hinge cover included with the literature bag is optional. To install hinge cover: 1. Press hinge cover squarely over hinge. Hinge Cover Remove grille: Remove the grille (see GRILLE INSTALLATION section of DOOR ALIGNMENT AND ADJUSTMENT this guide). Align and adjust the door if it is not level or is not sealing Remove arrow clips: properly. If the door is not sealed, the unit may not cool properly, or excessive frost may form in the interior. NOTICE Properly aligned, the door’s gasket should be 1. With a puddy knife or other flat tool, gently pry each arrow clip from hinge mounting holes. 2. Set aside arrow clips to be reused on the opposite side. firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to ensure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the hinge side of the door. To align and adjust the door: 1. Gently pry off hinge cover from top of unit. 2. Loosen (do not remove) top and bottom hinge screws using a Philips screwdriver on the top and a 1/4” Remove top hinge and door: socket on the bottom. 1. Remove hinge cover from top of unit 3. Align door squarely with cabinet. 2. Hold door to keep it from falling. 4. Make sure gasket is firmly in contact with cabinet all 3. Remove top hinge from cabinet using a Philips screwdriver to remove three screws. the way around the door (no gaps). 5. Tighten bottom hinge screws. 6. Tighten top hinge screws and replace hinge cover. REVERSING THE DOOR Location of the unit may make it desirable to mount the door on the opposite side of the cabinet. The hinge hardware will be removed and reinstalled on the opposite side of the cabinet. Door Adjustments 21 USER GUIDE 4. Remove door by tilting forward and lifting door off Install top hinge and door: bottom hinge. Retain shoulder washers; they will be reused. 5. Use a Philips screwdriver to remove hinge pin and reinstall on the opposite surface of the hinge. 6. Install arrow clips in holes. Remove bottom hinge: 1. Remove bottom hinge from cabinet using a 1/4” 1. socket. Rotate door 180o and lift the door on to the bottom hinge. 2. Install hinge that was used on the opposite side of the unit. 3. Align edge of the hinge with the outer edge of the unit while inserting hinge pin into top of door. 4. Tighten three screws and replace hinge cover. Align and adjust the door: 2. Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind one or both screws on either side. Align and adjust the door (see DOOR ALIGNMENT AND ADJUSTMENT) Install grille Install bottom hinge: Install two or three screws, depending on model. Replace nuts if used. Door Adjustments 22 USER GUIDE First Use 4. Remove keg from refrigerator. 5. Lift handle and remove lid. 6. Fill keg with cold brew. assembled according to the instructions in GENERAL 7. Replace and lock down lid. INSTALLATION. 8. Reattach hoses. Initial startup requires no adjustments. If the unit was turned off, press and hold for 5 seconds to turn unit on. See “Control Operation” section for more details. NOTICE Temperature displayed reflects actual temperature inside unit. If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set points before loading. To dispense cold coffee, make sure the components are Fill the Keg DE-PRESSURIZE SYSTEM NOTICE Before attempting to fill the keg it is necessary to confirm system is not pressurized. 1. Shut off nitrogen tank by turning handle clockwise until it stops. 2. The pressure should be set around 20 - 30 PSI. Start at 25 PSI on regulated gauge; 7 PSI at infuser regulator. 1. Make sure red regulator valve is in the OFF position. 2. On top of Nitrogen tank, turn black handle counterclockwise until it stops. 3. Rotate the red regulator valve to ON Position; turn counterclockwise 1/4 turn until it stops Lift up on pressure release valve ring. Allow pressure to release. 3. Set Nitrogen Pressure Detach hoses from keg. (See General Installation section of this guide.) First Use 23 USER GUIDE 4. To adjust pressure, loosen locking nut, turn adjusting screw until desired pressure is reached, and retighten locking nut. Regulated Gauge Tank Pressure Gauge Locking Nut Adjusting Screw 5. On infuser regulator, pull out middle knob to unlock then turn knob until needle points at 7 - turn right to increase; left to decrease. Unlock 6. Lock Once set, lock in place by pressing middle knob in until it clicks. First Use 24 USER GUIDE Dispensing Coffee The left tap delivers still cold brew which is refreshing and less acidic than hot coffee. The right tap delivers nitrogen-infused coffee which is the ultimate cold brew experience. Thousands of micro-nitrogen bubbles are infused as the coffee is dispensed. This creates a naturally slightly sweet taste and thicker and smoother texture. Troubleshooting ISSUE CAUSE No/reduced liquid flow through faucet(s). The strainer inside of the filter bowl assembly is clogged or beginning to clog. See cleaning section Nitrogen source is empty or turned off. If applicable, assure that the nitrogen tank is not empty and that the nitrogen shutoff switch is in the on position (in-line with the tube). Also assure that the knob on top of the tank is turned all the way counterclockwise. If the tank is empty, replace it with a full one. Liquid and/or nitrogen ball lock disconnects are not fully connected to product tank. Attach the liquid/nitrogen ball lock disconnects to the product tank. If they already appear to be connected, disconnect/ reconnect them. The nose cone of the faucet is clogged. Detach the nose cone assembly from the stout faucet by turning it counterclockwise. Remove the stainless steel restrictor disc and inspect the small holes to assure that none of them are clogged. The system is dirty and requires a thorough line cleaning/sanitizing procedure. Follow the line cleaning procedure above to remove buildup and restore full flow. The secondary regulator is set to a pressure that is either too high or low. If there is less/more nitro effect than desired, use the black knob on the secondary regulator assembly to make a change. To adjust the secondary regulator, pull the black knob out until you feel a slight click. This is the adjustment mode. To increase the level of nitro, turn this knob clockwise. To decrease the level of nitro, turn the knob counterclockwise. Continue adjusting and pouring until the level of nitro meets your requirements. Once you have found your desired level of nitrogenation, push the black knob back in to lock it in place. The strainer inside of the filter bowl assembly is beginning to clog. See cleaning section The system is dirty and needs cleaned. See cleaning section Liquid leak. Loose connection, broken fitting/tube, or loose faucet, nose cone or filter bowl assembly. Immediately turn the nitrogen off to the system, disconnect the quick disconnects from the product tank and call customer support for consultation to assess the system. Nitrogen leak (system is using nitrogen even when faucets are closed). Product tank lid is not sealed completely. Remove the lid and reattach making sure that the lid is centered and sealed. Fitting is loose, disconnected, or broken. Immediately turn the nitrogen off to the system, disconnect the quick disconnects from the product tank and call customer support for consultation to assess the system. The product is pouring too warm/cold or is freezing in the lines. Hot/Warm - The refrigeration is not plugged in or turned on. Plug in the refrigerator and assure it is powered on. Frozen - The thermostat on the refrigeration needs adjusted. See control section The condenser coil on the refrigeration is dirty and needs cleaned. See condenser cleaning Too much or not enough nitrogen being infused into the product (head is too big or too small). First Use SOLUTION 25 USER GUIDE Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and hold for 5 seconds Unit will turn On or OFF Adjust Temperature Press or Toggle between ºF / ºC Hold and Control Operation When the display is flashing, press and release adjust the set point temperature. for 5 seconds The display will change units 26 or to USER GUIDE Airflow and Product Loading AIRFLOW External • Do not block the front grille - no additional clearance around sides, top or rear of unit is needed for ventilation • Do not install behind a closed door Internal • When loading, leave space between internal fans, vents, and side walls to allow air to circulate freely NOTICE Restricting airflow may result in poor product performance, product failure, and uneven internal temperatures and may freeze contents. Airflow & Product Loading 27 USER GUIDE Cleaning CLEANING VS. SANITIZING CLEAN INTERIOR COMPONENTS Use warm or hot water with dish soap to clean all removed This guide will address both the cleaning and the sanitizing components and interior surfaces. You may use a vinegar and of the unit. water solution in place of soap. Proceed to sanitizing. Clean the unit to remove dried food and spills, to prevent Note: Cleaning soaps and vinegar solutions are not build-up of grime, and to maintain the natural luster sanitizers. stainless steel surfaces. Sanitize the unit when exposed to raw meat juice or human germs such as from a sneeze or being touched by someone who is ill. Sanitizing the unit can also be part of regular cleaning routine. Stainless Surfaces Stainless door panels, handles and frames can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your stainless unit looking new by cleaning with a SANITIZE INTERIOR COMPONENTS AND SURFACES Choose a Commercial Sanitizer Safe for Stainless Steel • surface will actually be sanitized • • Some products require a wait time before rinsing • Verify the sanitizer you are using is safe for stainless steel. Mix Your Own Sanitizer Polish and Cleaner. Comparable products are acceptable. Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning weekly. Do not clean with steel wool pads. Isopropyl Alcohol (rubbing alcohol) 1. Fill a clean, empty spray bottle with isopropyl alcohol 2. Spray surface 3. Wait 20 minutes 4. Dampen a non-abrasive cloth with isopropyl alcohol and wipe down surface Do not use stainless steel cleaners or polishes on any glass surfaces. 5. 1. 2. a nonabrasive cloth. Always clean with the grain. Always finish with Claire® Stainless Steel Polish and Cleaner or comparable product to prevent further problems. paper towel. 3. Fill a clean, empty spray bottle with bleach solution. 4. Spray surface. 5. After 2-3 minutes, use clean potable water to thoroughly rinse off surface. Allow to air dry or dry with a disposable Using abrasive pads such as ScotchBrite™ will cause the graining in the stainless steel to become blurred. paper towel. 6. removal of the rust may not be possible. Sanitize the door and all holes where the hinges attach to the unit and the brackets attach to the door as well as all Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete Submerse small parts for no more than 3 minutes - rinse immediately and allow to air dry or dry with a disposable If any surface discoloring or rusting appears, clean it quickly with Bon-Ami® or Barkeepers Friend Cleanser® and Create a solution of 1 tablespoon of unscented bleach with one gallon of water. stainless steel on stainless steel surfaces (this includes glass, tile, and counter cleaners). Dry surface with a clean dry non-abrasive cloth Unscented Bleach and Water Clean any glass surfaces with a non-chlorine glass cleaner. Do not use cleaners not specifically intended for Many products require rinsing with water after use, especially when food will be touching the surface good quality all-in-one stainless steel cleaner and polish monthly. For best results use Claire® Stainless Steel Read the directions for proper use to ensure that the the screws. CLEAN EXTERIOR SURFACES Use Bon-Ami® or Barkeepers Friend Cleanser® and a nonabrasive cloth. Always clean with the grain. Always finish with Claire® Stainless Steel Polish and Cleaner or comparable product to prevent further problems. Cleaning 28 USER GUIDE INTERIOR CLEANING & SANITIZING Tap Heads NOTICE Clean the faucet with warm soapy water. Remove nose Do not use any solvent-based or abrasive cone and soak in the cleaning solution for at least five cleaners. These types of cleaners may transfer taste minutes. Rinse with clean potable water, dry and reattach. and/or odor to the interior products and damage or discolor the interior. Nose Cone Cleaning the System The system should be cleaned each time you change your coffee tank and before extended periods of non use using a solution of water and ULACOFFEECLEAN. One packet of ULACOFFEECLEAN (Stera-Sheen®) was included with your product and more can be purchased at u-line.com. Infuser Filter Disassemble by unscrewing the cap. Rinse cap and filter with warm potable water and reassemble. Notice Cap Confirm system is not pressurized by turning off nitrogen – turn handle clockwise. Release pressure in system by pulling up on the release valve. Filter Line and System Cleaning 1. Remove the contents, clean the keg with water warm soapy water, and rinse. 2. Pour the cleaning solution into keg, attach hoses and open the nitrogen valve to pressurize the system. 3. Place a bucket under the taps. Pull and hold the left tap open until approximately ½ gallon of cleaning solution is dispensed. Close the left faucet. Pull and hold the right faucet handle until ½ gallon of solution is dispensed. Discard solution. 4. Allow the cleaning solution to remain in the system for a minimum of five minutes. 5. Dispense approximately ¼ gallon of the solution through the left tap. Dispense the remaining solution from the right tap. No rinsing is required. 6. Unless refilling, remove lid from keg to allow keg to air dry. Cleaning Solution Preparation Follow safety instructions on packet. Mix ULACOFFEECLEAN with 2 gallons of warm (100°F/38°C) potable water. Cleaning 29 USER GUIDE DEFROSTING Under normal conditions this unit does not require manual defrosting. Minor frost on the rear wall or visible through the evaporator plate vents is normal and will melt during each cycle. If there is excessive build-up of 1/4” (6 mm) or more, manually defrost the unit. Ensure the door is closing and sealing properly. High ambient temperature and excessive humidity can also produce frost. ! CAUTION DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining. NOTICE The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. To defrost: 1. Disconnect power to the unit. 2. Remove all products from the interior 3. Prop the door in an open position (2 in. [50 mm] minimum). 4. Allow the frost to melt naturally. 5. After the frost melts completely, clean the interior and all removed components. (See INTERIOR CLEANING). 6. When the interior is dry, reconnect power and turn unit on. Cleaning 30 USER GUIDE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary. ! WARNING Disconnect electric power to the unit before cleaning the condenser. NOTICE DO NOT use any type of cleaner on the condenser unit. Condenser may be cleaned using a vacuum, soft brush, or compressed air. 1. Remove the grille. See GRILLE INSTALLATION). 2. Clean the condenser coil using a soft brush or vacuum cleaner. 3. Install the grille. Condenser Cleaning Condenser 31 USER GUIDE Extended Non-Use VACATION/HOLIDAY, PROLONGED SHUTDOWN The following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service. 3. If any ice is visible inside the unit, allow ice to thaw naturally. 4. Clean and dry the interior of the unit. Ensure all water has been removed from the unit. 5. Clean the system. (See CLEANING) 6. The door must remain open to prevent formation of mold and mildew. Open door a minimum of 2” (50 mm) to provide the necessary ventilation. WINTERIZATION If the unit will be exposed to temperatures of 40oF (5oC) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. ! CAUTION Damage caused by freezing temperatures is not covered by the warranty. Extended Non-Use 32 USER GUIDE Troubleshooting • Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid. BEFORE CALLING FOR SERVICE • Condenser Fan: Air moving through a condenser may be heard. • Automatic Defrost Drain Pan: Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle. If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the function of the control. If the problem persists, read the NORMAL OPERATING SOUNDS and TROUBLESHOOTING GUIDE sections below to help you quickly identify common problems and possible TROUBLESHOOTING GUIDE causes and remedies. Most often, this will resolve the ! DANGER problem without the need to call for service. IF SERVICE IS REQUIRED ELECTROCUTION HAZARD. Never attempt to If you do not understand a troubleshooting remedy, or your repair or perform maintenance on the unit product needs service, contact U-Line Corporation directly before disconnecting the main electrical power. at +1.414.354.0300. Troubleshooting - What to check when problems occur: When you call, you will need your product Model and Serial Problem Possible Cause and Remedy interior of your product. Interior Light Does Not Illuminate If the unit is cooling, it may be in Sabbath mode. NORMAL OPERATING SOUNDS Light Remains on When Door Is Closed. Turn off light switch if equipped. Adjust light actuator bracket on bottom of door. Unit Develops Frost on Internal Surfaces. Ensure the door is closing and sealing properly. Unit Develops Condensation on External Surfaces. The unit is exposed to excessive humidity. Moisture will dissipate as humidity levels decrease. Product is Not Cold Enough Air temperature does not indicate product temperature. See CHECKING PRODUCT TEMPERATURE below. Adjust the temperature to a cooler set point. Ensure unit is not located in excessive ambient temperatures or in direct sunlight. Ensure the door is closing and sealing properly. Ensure the interior light has not remained on too long. Ensure nothing is blocking the front grille, found at the bottom of the unit. Ensure the condenser coil is clean and free of any dirt or lint build-up. Numbers. This information appears on the Model and Serial number plate located on the upper right or rear wall of the All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components. Despite this technology, your model may make sounds that are unfamiliar. Normal operating sounds may be more noticeable because of the unit’s environment. Hard surfaces such as cabinets, wood, vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises. Listed below are common refrigeration components with a brief description of the normal operating sounds they make. NOTE: Your product may not contain all the components listed. • Compressor: The compressor makes a hum or pulsing sound that may be heard when it operates. Troubleshooting 33 USER GUIDE CHECKING PRODUCT TEMPERATURE Causes which affect the internal temperatures of the cabinet include: • Temperature setting. • Ambient temperature where installed. • Installation in direct sunlight or near a heat source. • The number of door openings and the time the door is open. To check the actual product temperature in the unit: • The time the internal light is illuminated. (This mainly affects product on the top rack or shelf.) 1. Partially fill a plastic (nonbreakable) bottle with water. • Obstruction of front grille or condenser. 2. Insert an accurate thermometer. 3. Tighten the bottle cap securely. 4. Place the bottle in the desired area for 24 hours. 5. Avoid opening the unit during the testing period. 6. After 24 hours, check the temperature of the water. If required, adjust the temperature control in a small increment (see CONTROL OPERATION). Troubleshooting 34 Wire Diagram 35 Door switch Zone temp Evap temp 6 Us e FUSE Open Light blue Black N.C. White 5 1 5 Compressor NEUTRAL WHITE (115V) DARK BLUE (220-240V) 115 V (If Applicable) POWER CORD ASSEMBLY LIVE BLACK (115V) BROWN (220-240V) PLUG 220-240 VOLT Wire Diagram Light Evap/Cond fan 1 1 fac e rI nt er 42376_C USER GUIDE Programming USER GUIDE Product Liability Field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, the technician should call the manufacturer for further explanation. While inspecting for defects or installation issues, photos should be taken to document any damages or issues found. During the assessment, if the service technician is able to find the source of the damage and it can be resolved by replacement of a part, the servicer is authorized to replace the part in question. The part that caused the damage must be returned to the manufacturer in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part. If the service technician determines the damage is the result of installation issues (water connection/drain, etc.), the consumer would be notified and the issues shall be resolved at the direction of the consumer. If damage is evident and the service technician is unable to find the source, the manufacturer must be contacted at +1.616.754.5601 for further direction. 1260 Van Deinse St. Greenville, MI T: +1.616.754.5601 Website: vikingrange.com/commercial Product Liability 36 USER GUIDE Parts VCDE215-SSH1A 1 1 ANTI TIP BRACKET 80-54221-00 2 BACK PANEL 80-55350-05 3 CASTER, 3" NON-LOCKING * 80-55674-00 4 CASTER, 3" LOCKING * 80-55674-01 5 COFFEE DISPENSER CLEANER * 6 COMPRESSOR ASSEMBLY 80-55548-00 7 CONDENSER ASSEMBLY 80-55453-01 8 CONDENSER FAN 80-54014-00 9 CONTROL ASSEMBLY 80-55552-00 10 DISPLAY, UI, MAIN BOARD 80-55507-01 11 DOOR ASSEMBLY 80-55560-02 12 DRAIN PAN 80-54524-00 13 DRAIN TROUGH * 80-55484-00 14 DRIER 80-54055-00 15 EVAPORATOR ASSEMBLY 80-55458-00 16 EVAP FAN & COVER 80-54151-03 17 GASKET, DOOR 80-54213-00 18 GRILLE ASSEMBLY 80-55555-03 19 HINGE ASSEMBLY 80-55556-00 20 MAIN BOARD 80-55507-00 21 PACKAGING * 80-55563-00 22 POWER CORD, EXTERNAL * 80-55278-00 23 POWER CORD, INTERNAL * 80-55553-00 24 THERMISTOR 80-54006-00 25 WIRE HARNESS * 80-55402-00 2 19 15 16 24 18 9,10 11 17 * NOT PICTURED 6 8 10 20 12 14 7 Parts 37 ULACOFFEECLEAN USER USER GUIDE GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A Specifications Gloves and Eye Protection must be used. For R-600a refrigerant service tips and more videos, go to: www.u-line.com/videos. ! WARNING Flammability warnings for a pure-iso-butane refrigerant. R-600a is considered non-toxic, but is flammable when mixed with air. Keep a dry powder type fire extinguisher in the work area. R-600a is heavier than air, do not allow any leakage/migration to low areas such as basements and stairs. Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants. R-600A Specifications approved containers. 38 R-600A Specifications 1 USER USER GUIDE GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE ! WARNING Only skilled and well trained service technicians permitted to service R-600a equipped products. R-600A SPECIFICATIONS/LABELING R-600a equipped products are labeled (both the unit and the compressor). R-600a is colorless and odorless. All tools and equipment must be approved for use with R-600a refrigerant. R-600a is considered non-toxic, but is flammable when mixed with air. Local, state and federal laws, standards must be observed along with proper certification and licensing. Ventilation is required during servicing. No conversions to R-600a from any other refrigerants. OEM R-600a equipped unit only. Service area must be free of ignition sources. Do not remove or alter any R-600a labeling on the product. Use only a refrigerant grade R-600a from a properly labeled container. RECOVERING/RECLAIMING R-600A (R-600a has been exempted from recovery/reclaiming requirements by the US EPA) No smoking is allowed in the service area. Recovery/Reclaiming equipment must be approved for use All replacement electrical components must be with R-600a. OEM and installed properly (sealed and covered). If the evaporator is cold prior to service, it must be thawed prior to service. When using a vacuum pump, start pump before opening refrigeration system. Ensure the evaporator is at room temperature prior to recovery/reclaiming R-600a. Use a common piercing pliers or piercing valve to remove R-600a from the compressor process tube. (Note: Piercing devices must not be left on the system and must be replaced with a Schrader type valve.) Vacuum pump and recovery equipment should be at least 10 feet from the work area. It is recommended that a simple LPG gas detector is on site during service. Ensure that all R-600a is removed from the system prior to brazing any part of the sealed system. Only a clean, dry leak free system should be charged with R-600a. R-600A Specifications 39 R-600A Specifications 2 USER GUIDE GUIDE USER u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed. atmosphere. When re-brazing, proper ventilation is required along with constant monitoring for the presence of R600a refrigerant. The filter dryer must be replaced any time the sealed system is serviced. No system should be open to the atmosphere for longer than 15 minutes to avoid moisture migration into the system components. LEAK DETECTION The recovery cylinder must be evacuated (no air inside) prior to accepting R-600a. The recovery cylinder must not be filled more than 45% safe fill level and refrigerants must not be mixed. After removal of the R-600a, the unit can be charged with dry nitrogen or helium. Electronic leak detection or soap solution can be used to check for nitrogen/helium leaks. The recovery cylinder must be clearly marked with R600a and Flammable Warning labels. Ensure proper ventilation during recovery/reclaiming of R600a. Start vacuum pump/recovery pump prior to piercing the compressor process tube. Follow recovery/reclaim OEM instructions for the specific equipment used. SYSTEM REPAIR Ensure no residual R-600a refrigerant is left within the Never use a halide torch or lighted match to check the system for leaks at any time. system prior to repair (simple venting is not sufficient). The high side of the refrigeration system (compressor Evacuate and charge with dry nitrogen for leak checks. discharge to outlet of drier) must be leak tested with the compressor running. Repair leaks or replace system parts as required. R-600A Specifications 40 R-600A Specifications 3 USER GUIDE GUIDE USER u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure). Never apply a torch to a charged R-600a refrigeration system. RECHARGING No air is ever to be allowed inside the refrigeration system (R-600a refrigerant or dry nitrogen only). Use OEM replacement service parts and do not alter the construction of the unit. Never use a torch on a fully charged refrigeration system. Install a Schrader Type access port on the compressor process stub. Evacuate the system to 100 microns prior to charging. Weigh in the R-600a charge using a refrigerant scale. (run compressor an extra two minutes to clear the charging hoses). Seal the Schrader Type access port, a proper cap and seal must be used to close the system. SUMMARY Safely handling R-600a requires proper procedures and training. R-600a approved service tools must be used. R-600a labeling must not be removed or altered. R-600A Specifications 41 R-600A Specifications 4 USER GUIDE System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Condition Suction Pressure Suction Line Compressor Condenser Discharge Capillary Tube Evaporator Wattage Normal Normal Slightly below room temperature Very hot Very hot Warm Cold Normal Overcharge Higher than normal Very cold may frost heavily Slightly warm to hot Hot to warm Cool Cold Higher than normal Warmnear room temperature Hot Warm Warm Extremely cold near inlet - Outlet below room temperature Lower than normal Undercharge Lower than normal Partial Restriction Somewhat Warmlower than near room normal vacuum temperature Very hot Top passes warm Lower passes cool (near room temperature) due to liquid Room temperature (cool) or colder Extremely cold near inlet - Outlet below room temperature backing up Lower than normal Complete Restriction In deep vacuum Room temperature (cool) Room temperature (cool) Room temperature (cool) Room temperature (cool) No refrigeration Lower than normal No Gas 0 PSIG to 25” Room temperature (cool) Cool to hot Room temperature (cool) Room temperature (cool) No refrigeration Lower than normal COMPRESSOR CONDENSER DRYER CAPILLARY TUBE System Diagnosis Guide 42 EVAPORATOR USER GUIDE Compressor Specifications FMXA9C REFRIGERANT R600A VOLTAGE 230 VAC FREQUENCY 43-134 Hz Electrocution can cause death or serious injury. START WINDING 20 Ohm at 77o F Burns from hot or cold surfaces can cause serious RUN WINDING 20 Ohm at 77o F injury. Take precautions when servicing this unit. RUN TO START 20 Ohm at 77o F LRA 1.7 A FLA 1.7 A STARTING DEVICE Inverter CF02C05 OVERLOAD Inverter CF02C05 ! DANGER Disconnect the power source. Do not stand in standing water when working around electrical appliances. *All resistance readings are + 10% Make sure the surfaces you touch are not hot or frozen. Do not touch a bare circuit board unless you are wearing an anti-static wrist strap that is grounded to an electrical ground or grounded water pipe. Handle circuit boards carefully and avoid touching components. Compressor Specifications 43 USER GUIDE Troubleshooting - Extended ! CAUTION Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected from the unit. NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components. Despite this technology, your model may make sounds that are unfamiliar. Normal operating sounds may be more noticeable because SPECIFIC ERRORS AND ISSUES The advanced diagnostic capabilities of the electronic controls utilized on the 1, 3, and 5 Class units allow for easy and thorough troubleshooting. Navigation of the control is the key and is explained in the CONTROL OPERATION section of the manual, along with control button layout, control function descriptions, a service mode menu and service menu selection of the unit’s environment. Hard surfaces such as cabinets, wood, vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises. Listed below are common refrigeration components with a brief description of the normal sounds they make. NOTE: Your product may not contain all the components listed. • sound that may be heard when it operates. explanations. Verification of temperature and thermistor performance can • • Corp, “Customer Care Facility” at +1.414.354.0300 for Condenser Fan: Air moving through a condenser may be heard. Included in this section are some diagnostic tips; if additional help is required, please contact the U-Line Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid. be identified by directly viewing thermistor readings in the service mode. Compressor: The compressor makes a hum or pulsing • Automatic Defrost Drain Pan: Water may be heard dripping or running into the drain pan when the unit is assistance. in the defrost cycle. Solenoid Valves: An occasional clicking sound may be heard as solenoid valves are operated. Troubleshooting Extended 44 USER GUIDE TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify proper air flow through condenser. Is condenser clean? Confirm condenser fan operation. Frozen Product Frost Buildup Inside Unit Display Not Working Compressor not operating Test overload and relay, replace as needed. Compressor operating - no cooling Refer to System Diagnosis Guide. Control set too cold Adjust Set Point Temp accordingly. Thermistor failure Check Error Log in Service Mode, OHM thermistor. Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry. Check distribution of product in unit. Thermistor failure OHM thermistor Display unplugged Verify that both ends of the display wiring are firmly connected. Display wiring broken or damaged Perform continuity test of wiring and replace as needed. Interior Lights Not Working Door switch misaligned or defective Check the function of reed switch and door magnet adjustment. Noisy Refrigeration tubing touching cabinet Carefully reposition tubing. Fan blade obstruction (wiring, foam insulation, packaging material) Remove obstruction. Troubleshooting Extended 45 USER GUIDE MAIN CONTROL ! CAUTION The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures before attempting to remove the board for replacement or service. Follow the guidelines below to fully test and diagnose the main control. Precautions must be taken while working with live electrical equipment. Be sure to follow proper safety procedures while performing tests on live systems. Power Fault PLUNGER SWITCH If the unit does not (or seems to not) power on, follow the A plunger switch is used to monitor door state. When the flow chart below to help diagnose the issue. Before begin- door is closed it comes into contact with the plunger which ning it is important to first verify the unit is not simply set closes a circuit which turns the light and display off. When to sabbath mode. the door is open the plunger moves outward and opens the circuit. If the door is left open for longer than 5 minutes the switch will trigger an error code and set an audible Check Voltage At Wall Outlet No Voltage Alert Customer Of Power Failure No Voltage Replace Power Cord No Continuity Replace Fuse warning. Voltage Verify Voltage At Main Control Voltage Input Voltage Check Fuse F1 For Continuity Continuity Connect Test Display Cycle Power And Check For Operation Operating Inspect Customer UI and Data Cable Yes Replace Main Board Not Operating Is the Plunger Switch Operating Properly? No Replace Plunger Switch Troubleshooting Extended 46 USER GUIDE Control Operation-Service UI BUTTON LAYOUT 1. Up Button -Increases temperature -Navigates through service menu -LED activated with button activation 2. Down Button -Decreases temperature -Navigates through service menu -LED activated with button activation 3. Light Button -Activates light for 3 hours on select models -Used to select items in service menu -LED activated with button activation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES Enter menu by pressing Defrost Duration Use or Display shows “df” (defrosting). This controls how to increase/reduce defrost duration. Press Press Defrost Period Exit Menu Control Operation-Service Use once again. Use or to to increase/reduce tempera- ture. Press Display shows the interval in which the unit defrosts in hours. again. or long the unit defrosts. to select. increase/reduce defrost period. Press Set Offset Temperature for more than 5 seconds. Each adjustment for this setting is 1 degree: Positive = colder Negative = warmer and release 47 USER USER GUIDE GUIDE Thermistors Thermistor u-line.com Thermistor Data Thermistor Resistance Resistance Data Thermistors are used for various temperature readings. Thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a Thermistors provide reliable temperature readings resistance which varies based on surrounding temperatures. using a resistance which varies based on surrounding If a faulty thermistor is suspected, it may be tested using temperatures. If a faulty thermistor is suspected it may be an accurate ohmmeter. tested using an accurate ohmmeter. Temp (F) Thermistor connections must be kept clean. A thermistor Both thermistors in the unit are identical. If a thermistor connection that has become corroded can cause resistance is suspected of being defective, the resistance can be values from the thermistor to change as they pass through verified. Place the thermistor in an ice water bath, the a dirty connection to the board. resistance should read 16.1k Ohms +/-5% on your meter. It is for that reason that we apply dielectric grease to all of Thermistor connections must be kept clean. A thermistor our thermistor connections. Dielectric grease will help to connection that has become corroded can cause resistance keep thermistor connections clean and dry. values from the thermistor to change as they pass through Temp (C) Nominal Resistance (OHMS)* -40 -40 169157 -31 -35 121795 -22 -30 88766 -13 -25 65333 -4 -20 48614 5 -15 36503 14 -10 27681 23 -5 21166 32 0 16330 41 5 12696 50 10 9951 59 15 7855 68 20 6246 a dirty connection to the board. If you change a thermistor in the unit, please re-apply 77 25 5000 dielectric grease to the connection. If you encounter a dirty It is for that reason that we apply dielectric grease to all of thermistor connection, you should replace the thermistor our thermistor connections. Dielectric grease will help to and the thermistor harness. keep thermistor connections clean and dry. 86 30 4029 95 35 3266 104 40 2665 113 45 2186 122 50 1803 131 55 1495 140 60 1247 149 65 1044 158 70 879 167 75 743 176 80 631 This unit has one thermistor located along the right hand If you change a thermistor in the unit please re-apply sidewall of the ice bin. It is used to maintain the ice level in dielectric grease to the connection. If you encounter the bin. a dirty thermistor connection, you should replace the thermistor and the thermistor harness. Thermistor error information can be found in the Control Operations - Service section. * (+/- 5%) This unit has one thermistor. Thermistor one (Zone): Located along the right hand side wall. It is used to maintain the operating temperature within that zone. THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails, the unit will continue to cool in a backup mode (Self Preservation Mode) to preserve the integrity of the contents. The unit will otherwise operate normally. Thermistor Thermistor 48 USER GUIDE Defrost Outdoor units defrost every 12 hours of compressor runtime for 45 minutes. If you have verified that the unit does not have an ambient air leak, utilize the Control Operation - Service section and adjust unit to defrost every 9 hours for 60 minutes Defrost 49 USER GUIDE Remove Fan and Cover 6. Remove insulating foam from refrigerant line passthrough hole as needed to gain clearance for fan plug. CONVECTION COOLING This unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, cools product faster and increases energy efficiency. Evaporator Fan The evaporator fan is responsible for circulating warm air 7. Remove internal shelving. 8. Remove rear shelf clips, fronts can remain. 9. Remove thermistor cover. 10. Remove two evaporator cover screws from top of from the refrigeration zone, past the evaporator and back evaporator plate. into the refrigerated zone. The evaporator fan is factory set to have a 1 minute delay at the beginning of a cooling cycle. This delay gives the evaporator time to cool properly before warm air is passed over it. The fan will continue to run for an additional 2 minutes at the end of a cooling cycle. Fan delay times can be modified through the service menu. Evaporator Cover Screws Evaporator fan operation is also determined by door switch state. If the door switch circuit opens, the fan will stop. When the door switch circuit is closed the fan will either continue running with the cooling cycle, or if not currently cooling, the fan will run for 1 minute to circulate air and clear any condensation that may have appeared on glass 11. Grasp evaporator cover, pull forward and up as bottom of cover is installed behind the front edge of the drain doors and shelves. trough. Note: If the unit is set to sabbath mode, the evaporator fan will no longer respond to the state of the door switch. 12. While pulling the evaporator cover clear of the unit, it may be necessary to use your free hand to manipulate In order to operate efficiently, the evaporator fan blade the fan plug end through the pass-through hole. and vents should be unobstructed and free of any dust buildup. Evaporator Fan Replacement 13. Remove the 4 screws mounting the fan shroud to the evaporator plate. Should the evaporator fan need to be replaced follow the steps below. 1. Remove any product from the unit. 2. Remove unit from cabinetry to access rear. 3. Disconnect power to the unit. 4. Remove back panel from unit. 5. Disconnect fan electrical connection at rear of unit. Remove Fan and Cover Air Flow 50 USER GUIDE 14. Remove and replace fan. Take special care to properly route fan wire. NOTICE Fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting location. 15. Installation is the reverse of removal. 16. Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough. 17. Use sealant gum to seal any openings at rear of unit before replacing rear cover. 18. Reinstall unit taking care to level, space and secure as found. Remove Fan and Cover 51 Viking Commercial Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. Service provided by Viking under the above warranty must be performed by a Viking factory authorized servicer, unless otherwise specified by Viking. Service provided during normal business hours. Five Year Sealed System Limited Warranty For five years from the date of original purchase, Viking will repair or replace the following parts, labor not included, that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by Viking under the above warranty must be performed by a Viking factory authorized servicer, unless otherwise specified by Viking. Service provided during normal business hours. Terms These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and maintained in accordance with your product’s User Guide. The remedies described above for each warranty are the only ones that Viking will provide, either under these warranties or under any warranty arising by operation of law. Viking will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal rights, and you may also have other rights which vary from state to state. Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts described in the section related to the one year limited warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. • Service must be dispatched by the factory to be eligible for warranty coverage. • The warranties only apply to the original purchaser and are non-transferable. • Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties. • The start of Viking's obligation begins on the shipment date from the factory. • Food, beverage, and medicine loss are not covered by these warranties. • If the product is located in an area where Viking factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a Viking factory authorized service location at your own cost and expense. • Any product purchased as a floor display is covered by a 90-day warranty only. • Signal issues related to Wi-Fi connectivity are not covered by these warranties. For parts and service assistance, or to find Viking factory authorized service near you, contact Viking: 1260 E. Van Deinse Street, Greenville, MI 48838 • [email protected] • +1.616.754.5601 All Rights Reserved. | Publication Number 30717 | 02/2024 Rev. A 52 ">
Download
Advertisement
Key features
Nitrogen Infusion
2 Tap Dispenser
Temperature Control
Filter Bowl Assembly
Keg Compatibility
Free-standing & Built-in Installation
Frequently asked questions
To adjust the nitrogen pressure, pull out the middle knob on the infuser regulator. Then, turn the knob clockwise to increase pressure or counterclockwise to decrease pressure. Once you've found your desired level, press the knob back in to lock the setting.
The manual states that the unit is designed to operate between 50°F (10°C) and 90°F (32°C). However, it also notes that higher ambient temperatures may reduce the unit's ability to reach low temperatures or reduce ice production.
The manual recommends cleaning the condenser coil every six months to ensure proper performance. To do this, you'll need to unplug the unit, remove the grille, and use a vacuum cleaner with a brush attachment to clean the coils.