Pool & Spa Heaters

P R O U D L Y M A D E I N T H E U . S . A . S I N C E 1 9 5 5

QUALITY AND RELIABILITY:

A COATES COMMITMENT SINCE 1955

Since we built our first pool heater in 1955, Coates has been the name to trust for quality and reliability in water heating equipment.

Today, the Coates Heater Company manufactures the largest, most complete selection of electric heaters for pools and spas. All Coates models, from our largest capacity

300kw commercial pool heater to the smallest 1.5kw in-line spa heater, blend the latest technology, the finest materials and innovative engineering to provide the kind of quality and reliability you've come to expect from Coates. Easy to use sizing calculator available at our website.

Visit

.com

There are two ways to size a pool/spa. Either by the heat loss, which is used for maintaining the temperature, or the temperature rise, which is used when heat up time is a factor.

TEMPERATURE RISE METHOD:

For use when a rapid change in temperature is important.

(common for spas)

HEAT LOSS METHOD:

For use when maintaining water temperature.

(common for pools)

V = Volume of pool/spa in gallons

= Length x Width x Depth x 7.5

kw = Kilowatt rating of heater

D T = Temperature rise in °F/hour

Do you want to know the kilowatt required to achieve a desired temperature rise?

kw = V x 8.3 x DT*

3413

Do you want to know the temperature rise a kilowatt rating will achieve?

D T = KW x 411*

V

A = Surface area of pool/spa (ft 2 )

= Length x Width

T = Difference between average air temp and desired

water temp (°F).

kw = Kilowatt rating of heater kw = A x T x 10**

3413

** Assumes a heat loss of 10 BTU/hour per ft 2 per °F.

Assumes a 3-1/2 mph maximum wind and

partial sun exposure. 1kw= 3,413 BTU/hour

* Assumes spa is covered when not in use.

Formula does not account for heat loss — actual heat

up times may vary.

www.CoatesHeater.com

[253] 872-7256

Compact and efficient, Coates in-line spa heaters feature stainless steel tanks and replaceable incoloy elements.

STANDARD FEATURES:

> Replaceable incoloy element

> Stainless steel tank

> Contactors (Mod. 6ILS)

> Pressure switch

> Close differential thermostat

> Control box with powder coat finish

> Manual reset high temp limit

> Element "on" light

> 1-1/2 x 2 inch union

connections for PVC pipe

> U.L. listed

CONTROL BOX DIMENSIONS

1.5ILS: 12''L x 5-1/2''W x 5-1/2''H (9 lbs.)

6ILS: 12''L x 5-1/2''W x 5-1/2''H (10 lbs.)

OVERALL LENGTH: 19-1/2''

WITHOUT UNIONS: 15''

MODEL NUMBER

1.5ILS

6ILS

KW

1.5

5.5

VOLTAGE

120

240

PHASE

1

1

AMPS

12

23

BTU'S P/H

5,120

18,772

SHIPPING WT.

9 lbs.

10 lbs.

C

UL

LISTED

US

The built-in pressure switch prevents operation when there is no water flow and allows operation at flow rates between

15GPM and 80GPM. The stainless steel tank is designed to optimize heat transfer by directing the water flow over the incoloy elements efficiently.

STANDARD FEATURES:

> Incoloy heating elements

> Close differential thermostat

> Manual reset high temp limit

> Pressure switch

> Heavy duty contactors

> Element & flow "on" lights

> Piping connections:

1-1/2 x 2" union connections for PVC pipe

MODEL NUMBER

12406ST

12411ST

KW

5.5

11.0

VOLTAGE

240

240

Easy to use sizing calculator available at our website. V isit www.CoatesHeater

.com

D I M E N S I O N S

17-1/2" L x 4" W x 14" H

PHASE

1

1

AMPS

23

46

BTU'S P/H

18,772

37,543

SHIPPING WT.

17 lbs.

18 lbs.

C

UL

LISTED

US www.CoatesHeater.com

These pool and spa heaters feature a flow switch to prevent operation when there is no water flow. An all stainless steel tank for long life and corrosion resistance is also standard. Available in single phase and three phase configurations.

STANDARD FEATURES:

> Incoloy heating elements

> Close differential thermostat

> Manual reset high temp limit

> Flow switch

> 1-1/2" male NPT connections

> Stainless steel tank

> Heavy duty contactors

> Element & flow “on” lights

> Element fusing on

units rated over 48 amps

D I M E N S I O N S

CE: 19''L x 10''W x 11''H (47 lbs.)

CPH: 24''L x 12''W x 13''H (68 lbs.)

KW

12

15

18

24

30

MODEL NUMBER

12412CE

12415CE

12418CE

12424CPH

12430CPH

AMPS

50

63

75

100

125

KW

12

15

18

24

30

MODEL NUMBER

32012CE

32015CE

32018CE

32024CPH

32030CPH

N O T E : Heaters also available in 220v, 380v, and 415v.

Please see export brochure for details.

AMPS

34

42

50

67

84

KW

12

15

18

24

30

MODEL NUMBER

34812CE

34815CE

34818CE

34824CPH

34830CPH

AMPS

15

19

22

29

37

KW

12

15

18

24

30

MODEL NUMBER

36012CPH

36015CPH

36018CPH

36024CPH

36030CPH

AMPS

12

15

18

24

29

Along with the same features as our 12-24kw heaters, our 36-57kw heaters now include a digital thermostat for more precise control of pool water temperature.

STANDARD FEATURES:

> Incoloy heating elements

> Digital thermostat

> Manual reset high temp limit

> Flow switch

> 2" male NPT connections

> Stainless steel tank

> Heavy duty contactors

> Element, flow and high

temp “on” lights

> Element fusing on units

rated over 48 amps

D I M E N S I O N S

PHS: 28''L x 15''W x 15''H (100 lbs.)

KW

36

45

54

57

MODEL NUMBER AMPS

12436PHS-3 150

12445PHS 188

12454PHS-4 225

12457PHS 238

KW

36

45

54

57

MODEL NUMBER

32036PHS-3

32045PHS

32054PHS-4

32057PHS

N O T E : Heaters also available in 220v, 380v, and 415v.

Please see export brochure for details.

AMPS

100

125

150

158

KW

36

45

54

57

MODEL NUMBER

34836PHS-3

34845PHS

34854PHS-4

34857PHS

AMPS

44

55

65

69

KW

36

45

54

57

MODEL NUMBER

36036PHS-3

36045PHS

36054PHS-4

36057PHS

AMPS

35

44

52

55

C

UL

LISTED

US

Designed for high capacity commercial pool installations, Coates heaters incorporate design features that increase service life, dependability and provide ease of servicing. Corrosion resistant all stainless steel tank surfaces and low watt density incoloy elements mounted on four-bolt stainless steel flanges provide long, trouble-free service life.

All electrical components are easily accessible under the conveniently hinged cover. Terminal blocks are provided for simplified power supply wiring.

STANDARD FEATURES:

> Stainless steel tank

> 35psi design pressure – ASME

"U" stamp

> Incoloy heating elements

> Close differential thermostat

> Manual reset high temp limit

> 120V control circuit

> Lighted “on/off” switch

>

>

>

Element & flow "on" lights

Pressure relief valve*

> Flow switch*

U.L. listed for indoor installation

* Installation required

MODEL NUMBER

PHS-20

KW

180

210

240

270

300

FLOW RATE

MIN. GPM MAX. GPM 208V

100

100

125

125

125

175

175

175

175

175

220V

THREE PHASE AMPERAGE

240V 346V 380V 415V

Consult

Factory

For Availability

274

319

365

410

456

250

292

334

375

417

PHS-20

THREE PHASE

480V

217

253

289

325

361

600V

173

202

230

260

288

18'' Clearance required for heating element removal (typical each end)

18'' A

Outlet Conduit Entrance

S

S S

Inlet

S

S

Relief Valve Opening Drain

REAR VIEW

S

28''

28'' Clearance required to open top cover

(control access)

B

S

Heater Controls:

On/Off Switch,

Temperature

& High Limit

S

S

16''

(Min.)

C

S

FRONT

LEFT END

CANADIAN

REGISTRATION

ASME

C

UL

LISTED

US

PIPING SIZES: (PHS-20)

Inlet/Outlet .....................................3"

Drain ...........................................1/2"

Relief Valve ..................................3/4"

DESIGN PRESSURE:

PHS-20 ....................................35 PSI

D I M E N S I O N S

( I N C H E S ) :

MODEL NUMBER A B

PHS-20 54 26

C

28

SHIP WT.

450 lbs. www.CoatesHeater.com [253] 872-7256

HEATER COMPANY, INC.

P.O. Box 1750, Kent, Washington 98035 U.S.A. | Phone: (253) 872-7256 Fax: (253) 859-4660

© 2008 Coates Heaters, Inc. S/WD #106963 3M 4/2008 Printed in the U.S.A.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement