Today, the Coates Heater Company manufactures the largest, most complete selection of electric heaters for pools and spas. All Coates models, from our largest capacity
300kw commercial pool heater to the smallest 1.5kw in-line spa heater, blend the latest technology, the finest materials and innovative engineering to provide the kind of quality and reliability you've come to expect from Coates. Easy to use sizing calculator available at our website.
Visit
.com
There are two ways to size a pool/spa. Either by the heat loss, which is used for maintaining the temperature, or the temperature rise, which is used when heat up time is a factor.
TEMPERATURE RISE METHOD:
For use when a rapid change in temperature is important.
(common for spas)
HEAT LOSS METHOD:
For use when maintaining water temperature.
(common for pools)
V = Volume of pool/spa in gallons
= Length x Width x Depth x 7.5
kw = Kilowatt rating of heater
D T = Temperature rise in °F/hour
Do you want to know the kilowatt required to achieve a desired temperature rise?
kw = V x 8.3 x DT*
3413
Do you want to know the temperature rise a kilowatt rating will achieve?
D T = KW x 411*
V
A = Surface area of pool/spa (ft 2 )
= Length x Width
T = Difference between average air temp and desired
water temp (°F).
kw = Kilowatt rating of heater kw = A x T x 10**
3413
** Assumes a heat loss of 10 BTU/hour per ft 2 per °F.
Assumes a 3-1/2 mph maximum wind and
partial sun exposure. 1kw= 3,413 BTU/hour
* Assumes spa is covered when not in use.
Formula does not account for heat loss — actual heat
up times may vary.
www.CoatesHeater.com
[253] 872-7256
Compact and efficient, Coates in-line spa heaters feature stainless steel tanks and replaceable incoloy elements.
STANDARD FEATURES:
> Replaceable incoloy element
> Stainless steel tank
> Contactors (Mod. 6ILS)
> Pressure switch
> Close differential thermostat
> Control box with powder coat finish
> Manual reset high temp limit
> Element "on" light
> 1-1/2 x 2 inch union
connections for PVC pipe
> U.L. listed
CONTROL BOX DIMENSIONS
1.5ILS: 12''L x 5-1/2''W x 5-1/2''H (9 lbs.)
6ILS: 12''L x 5-1/2''W x 5-1/2''H (10 lbs.)
OVERALL LENGTH: 19-1/2''
WITHOUT UNIONS: 15''
MODEL NUMBER
1.5ILS
6ILS
KW
1.5
5.5
VOLTAGE
120
240
PHASE
1
1
AMPS
12
23
BTU'S P/H
5,120
18,772
SHIPPING WT.
9 lbs.
10 lbs.
C
UL
LISTED
US
The built-in pressure switch prevents operation when there is no water flow and allows operation at flow rates between
15GPM and 80GPM. The stainless steel tank is designed to optimize heat transfer by directing the water flow over the incoloy elements efficiently.
STANDARD FEATURES:
> Incoloy heating elements
> Close differential thermostat
> Manual reset high temp limit
> Pressure switch
> Heavy duty contactors
> Element & flow "on" lights
> Piping connections:
1-1/2 x 2" union connections for PVC pipe
MODEL NUMBER
12406ST
12411ST
KW
5.5
11.0
VOLTAGE
240
240
Easy to use sizing calculator available at our website. V isit www.CoatesHeater
.com
D I M E N S I O N S
17-1/2" L x 4" W x 14" H
PHASE
1
1
AMPS
23
46
BTU'S P/H
18,772
37,543
SHIPPING WT.
17 lbs.
18 lbs.
C
UL
LISTED
US www.CoatesHeater.com
These pool and spa heaters feature a flow switch to prevent operation when there is no water flow. An all stainless steel tank for long life and corrosion resistance is also standard. Available in single phase and three phase configurations.
STANDARD FEATURES:
> Incoloy heating elements
> Close differential thermostat
> Manual reset high temp limit
> Flow switch
> 1-1/2" male NPT connections
> Stainless steel tank
> Heavy duty contactors
> Element & flow “on” lights
> Element fusing on
units rated over 48 amps
D I M E N S I O N S
CE: 19''L x 10''W x 11''H (47 lbs.)
CPH: 24''L x 12''W x 13''H (68 lbs.)
KW
12
15
18
24
30
MODEL NUMBER
12412CE
12415CE
12418CE
12424CPH
12430CPH
AMPS
50
63
75
100
125
KW
12
15
18
24
30
MODEL NUMBER
32012CE
32015CE
32018CE
32024CPH
32030CPH
N O T E : Heaters also available in 220v, 380v, and 415v.
Please see export brochure for details.
AMPS
34
42
50
67
84
KW
12
15
18
24
30
MODEL NUMBER
34812CE
34815CE
34818CE
34824CPH
34830CPH
AMPS
15
19
22
29
37
KW
12
15
18
24
30
MODEL NUMBER
36012CPH
36015CPH
36018CPH
36024CPH
36030CPH
AMPS
12
15
18
24
29
Along with the same features as our 12-24kw heaters, our 36-57kw heaters now include a digital thermostat for more precise control of pool water temperature.
STANDARD FEATURES:
> Incoloy heating elements
> Digital thermostat
> Manual reset high temp limit
> Flow switch
> 2" male NPT connections
> Stainless steel tank
> Heavy duty contactors
> Element, flow and high
temp “on” lights
> Element fusing on units
rated over 48 amps
D I M E N S I O N S
PHS: 28''L x 15''W x 15''H (100 lbs.)
KW
36
45
54
57
MODEL NUMBER AMPS
12436PHS-3 150
12445PHS 188
12454PHS-4 225
12457PHS 238
KW
36
45
54
57
MODEL NUMBER
32036PHS-3
32045PHS
32054PHS-4
32057PHS
N O T E : Heaters also available in 220v, 380v, and 415v.
Please see export brochure for details.
AMPS
100
125
150
158
KW
36
45
54
57
MODEL NUMBER
34836PHS-3
34845PHS
34854PHS-4
34857PHS
AMPS
44
55
65
69
KW
36
45
54
57
MODEL NUMBER
36036PHS-3
36045PHS
36054PHS-4
36057PHS
AMPS
35
44
52
55
C
UL
LISTED
US
Designed for high capacity commercial pool installations, Coates heaters incorporate design features that increase service life, dependability and provide ease of servicing. Corrosion resistant all stainless steel tank surfaces and low watt density incoloy elements mounted on four-bolt stainless steel flanges provide long, trouble-free service life.
All electrical components are easily accessible under the conveniently hinged cover. Terminal blocks are provided for simplified power supply wiring.
STANDARD FEATURES:
> Stainless steel tank
> 35psi design pressure – ASME
"U" stamp
> Incoloy heating elements
> Close differential thermostat
> Manual reset high temp limit
> 120V control circuit
> Lighted “on/off” switch
>
>
>
Element & flow "on" lights
Pressure relief valve*
> Flow switch*
U.L. listed for indoor installation
* Installation required
MODEL NUMBER
PHS-20
KW
180
210
240
270
300
FLOW RATE
MIN. GPM MAX. GPM 208V
100
100
125
125
125
175
175
175
175
175
220V
THREE PHASE AMPERAGE
240V 346V 380V 415V
Consult
Factory
For Availability
274
319
365
410
456
250
292
334
375
417
PHS-20
THREE PHASE
480V
217
253
289
325
361
600V
173
202
230
260
288
18'' Clearance required for heating element removal (typical each end)
18'' A
Outlet Conduit Entrance
S
S S
Inlet
S
S
Relief Valve Opening Drain
REAR VIEW
S
28''
28'' Clearance required to open top cover
(control access)
B
S
Heater Controls:
On/Off Switch,
Temperature
& High Limit
S
S
16''
(Min.)
C
S
FRONT
LEFT END
CANADIAN
REGISTRATION
ASME
C
UL
LISTED
US
PIPING SIZES: (PHS-20)
Inlet/Outlet .....................................3"
Drain ...........................................1/2"
Relief Valve ..................................3/4"
DESIGN PRESSURE:
PHS-20 ....................................35 PSI
D I M E N S I O N S
( I N C H E S ) :
MODEL NUMBER A B
PHS-20 54 26
C
28
SHIP WT.
450 lbs. www.CoatesHeater.com [253] 872-7256
HEATER COMPANY, INC.
P.O. Box 1750, Kent, Washington 98035 U.S.A. | Phone: (253) 872-7256 Fax: (253) 859-4660
© 2008 Coates Heaters, Inc. S/WD #106963 3M 4/2008 Printed in the U.S.A.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project