ELPRO 415U-E-CX Long Range Wireless Ethernet Modem Installation Guide
PDF
Dokument
Reklama
Reklama
415U-E-CX INSTALLATION GUIDE Antenna installation When selecting an antenna, consider radio proximity. Use Figure 1 as a guide for installing an antenna and attaching it to the 415U-E-Cx. Figure 1. Antenna installation Antenna* Wavelength: 1 Wavelength (minimum) 360MHz = 33” (83cm) 400MHz = 30” (75cm) 480MHz = 25” (63cm) 930MHz = 13” (32cm) Connect Coax to building earth in accordance with 6.2 g) and 6.2 i) of IEC60728-11:2005 Stress Relief Loop Weatherproof Connections (recommended: 3M™ 23 selfbonding tape) Surge Arrestor (recommended) Coaxial Cable Mast GND 415U-E Earth Conductor at least 5 AWG (16 mm2) WARNING - EXPLOSION HAZARD Do not disconnect the device while the circuit is live unless the area is known to be non-hazardous. NOTE All connections must be SELV <50 Vac and <60Vdc. * For maximum range, install above local obstruc�ons. GND at least 11 AWG (4 mm2) Earth Stake Provide good ground connection to mast, module, and surge arrestor. If ground conditions are poor, use more than one stake. Models 415U-E-C1 – 148 to 174MHz Connecting to the module for configuration 415U-E-C3 – 360 to 400MHz • Download and install configuration utility software, available from the Elpro Technolgies website. www.elprotech.com 415U-E-C4 – 400 to 480MHz • Connect to PC using supplied USB cable. 415U-E-C5 – 470 to 520MHz 415U-E-C9 – 928 to 960MHz • Connect to the device by selecting USB connection and using the IP address 192.168.111.1 or 1.1.1.1 for older firmware (pre V2.28) • The PC will automatically be assigned an IP address from the module via DHCP. A new network adaptor will be created using IP address 192.168.1.2 (or 1.1.1.2) • Username: user • Password: user TECHNICAL NOTE EL-inst-415U-E-Cx_Dec24 EFFECTIVE Dec, 2024 An envirada group company 415U-E-CX INSTALL GUIDE Configuration Switches The following illistrations show the port connections on the 415U-E-Cx. Use the DIP switches in the side access panel to select analog input voltage or current, and to enable default configuration. LED Indicator Lights PWR RF 232 485 DIP Description OFF ON I/O Connectors 1 Unused Off On Signal Strength Indication 2 Default configuration Side Access Panel Factory use only USB Host Normal Enabled ON OFF Configuration Switches Input and Output connections The digital input/output channels can be wired as inputs or outputs. USB Port RS-232 Port High speed pulsed input B A - GND BAT SUP SUP - + + ETHERNET USB RS232 + D1 D2 SUPPLY RJ-45 Ethernet Port (connects to hub or switch) Power Supply Wiring The ground (GND) and “SUP –“ terminals are connected internally to the ground (Earth) terminal. Connect the screw terminal on the end plate to ground (Earth) for surge protection. GND BAT SUP SUP + USB RS232 - + TTL CMOS Output from other device SUPPLY Digital Input – Optional 10.8–15 Vdc Lead Acid + Battery 3A Fuse D1 D2 15-30 Vdc Supply Expansion I/O Power and RS485 serial connection An on-board RS‑485 terminating resistor provides line termination for long runs. Only enable terminating resistor on the last device connected on the RS‑485 cable. B A B A - TTL CMOS Output from other device + ETHERNET USB RS232 RS-485 Digital Output 115S-xx 115S-xx D1 B A - + B A D2 - + DC Load (Relay) Max 30VDC 200mA + – Device common Ground CONTACT Australia ELPRO Technologies 29 Lathe Street Virginia QLD 4014 T +61 7 3352 8600 E [email protected] W elprotech.com USA ELPRO Technologies Inc 2028 East Ben White Boulevard #240-5656 Austin, TX 78741-6931 T +1 855 443 5776 E [email protected] W elprotech.com HOW TO ORDER Simply send us an email at [email protected], contact your local distributor, or phone +61 7 3352 8600 An envirada group company ">
/
Stiahnuť
Len priateľské pripomenutie. Dokument si môžete pozrieť priamo tu. Ale čo je najdôležitejšie, naša AI si ho už prečítala. Dokáže vysvetliť zložité veci jednoducho, odpovedať na vaše otázky v akomkoľvek jazyku a pomôže vám rýchlo prechádzať aj tie najdlhšie alebo najkomplikovanejšie dokumenty.
Reklama