Below you will find brief information for WCS3900, WCS3905. This programming guide covers configuring the Wasp CCD scanners, including barcode symbology settings, keyboard connection, beep and delay options, and how to enable/disable specific barcode types. It also includes test symbols and technical specifications to help users set up the scanners for their applications.
Advertisement
Advertisement
Barcode Scanning Made Easy
Wasp Barcode Technologies
1400 10th Street
Plano, TX 75074 www.waspbarcode.com
0707US
Programming Guide
CCD Scanner Programming Guide
Please Read
Note: The Wasp
®
WCS3900 Series Scanners are ready to scan the most popular barcodes out of the box.
This manual should only be used to make changes in the
configuration of the scanner for specific applications. These scanners do not require software or drivers to operate. The scanner enters data as keyboard data. Please review this manual before scanning any of the programming barcodes in this manual.
Tech Tip
If you are unsure of the scanner configuration or have scanned the incorrect codes, please scan the default barcode on page 7.
This will reset the scanner to its factory settings.
Check Version
© Copyright Wasp Barcode Technologies 2007
No part of this publication may be reproduced or transmitted in any form or by any means without the written permission of Wasp Barcode Technologies. The information contained in this document is subject to change without notice.
Wasp and the Wasp logo are registered trademarks of Wasp Barcode Technologies. All other trademarks or registered trademarks are the property of their respective owners.
Wasp Barcode Technologies
Productivity Solutions for Small Business that
Increases Productivity & Profitability
• Barcode, data collection solutions
• Small business focus
• Profitable growth since 1986
• Over 200,000 customers
• Business unit of Datalogic SPA
Wasp ® Barcode Technologies
1400 10th Street
Plano, TX 75074
Phone: 214-547-4100 • Fax: 214-547-4101 www.waspbarcode.com
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 1
Table of Contents
Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Chapter 2. Barcode Symbologies . . . . . . . . . . . . . . . . . . . . .3
Chapter 3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chapter 4. Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Chapter 5. Setup & Configuration . . . . . . . . . . . . . . . . .6-28
1. Factory Default & Keyboard Connection . . . .7
2. Autosense Stand Mode . . . . . . . . . . . . . . . . .7
3. Beep and Delay . . . . . . . . . . . . . . . . . . . . . .8-9
4. Upper/Lower Case . . . . . . . . . . . . . . . . . . . .10
5. Keyboard Language . . . . . . . . . . . . . . . . . . .11
6. Preamble/Postamble Configuration . . . . . . .12
7. Terminator/Code ID . . . . . . . . . . . . . . . . . . .13
8. Enable/Disable Barcode Symbologies . . .14-15
9. Barcode Symbology Settings . . . . . . . . .16-28
Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Interleaved 2 of 5 and Code 93 . . . . . . . . . .17
Code 128 and UCC/EAN 128 . . . . . . . . . . . .18
MSI/Plessey . . . . . . . . . . . . . . . . . . . . . . . . .19
Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
UPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
UPC-A Supplemental / UPC-A to EAN-13 . .22
UPC-E . . . . . . . . . . . . . . . . . . . . . . . . . . .23-24
EAN-8 . . . . . . . . . . . . . . . . . . . . . . . . . . .25-26
EAN-13 . . . . . . . . . . . . . . . . . . . . . . . . . .27-28
Appendix A Barcode Test Symbols . . . . . . . . . . . . . . . .29-31
Appendix B ASCII Table . . . . . . . . . . . . . . . . . . . . . . . . .32-35
Appendix C Codes for PC . . . . . . . . . . . . . . . . . . . . . . . . . .36
Appendix D Technical Specifications . . . . . . . . . . . . . . . . . .37
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . .39
Product Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 2
Chapter 1
Introduction
Barcoding is the most common Automated Data Collection (ADC) technology providing timely, error-free information that can be used to increase productivity, accuracy, and efficiency in the workplace. Virtually every type of industry is using barcodes to replace keyboard data entry.
Studies have shown that a proficient data entry operator will make one error for every 300 characters that are manually entered. The error rate using barcodes is almost negligible and can be error-free using barcode symbologies with the check digit enabled.
The Wasp Charged Coupled Device (CCD) technology is a technique whereby a barcode is photographed, digitized, and electronically sampled by built-in photodetectors. The detectors process the measurement of every bar and space using the number of adjacent photodetectors which contrast a black mark and a white space. Wasp WCS3900 Series Scanners are extremely rugged since they have no moving parts. WCS3900 Series
Scanners plug into your PC’s USB or PS/2 port. As you scan a barcode, the barcode value is automatically displayed in your application (eg. an
Excel cell, inventory application, etc.) where the blinking curser is, just as if it had been typed on the keyboard.
Of all the hand held barcode scanning devices on the market, the CCD reader is the easiest to use and most cost effective for the typical business user. To activate the scanner, the user simply points the scanning aperture towards the barcode, pulls the trigger, and aims the red LED beam across the barcode. This scanner will work at a range of contact up to 1.5” away from the barcode.
2
2
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 3
Chapter 2
Barcode Symbologies
Barcodes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commercial products.
The bars and spaces in each symbol are grouped in such a way to represent a specific ASCII character or function. The interpretation of these groups is based on a particular set of rules called symbologies.
Various symbologies have been developed for particular applications.
Some examples are shipping and receiving, manufacturing, retail, healthcare, transportation, document processing and tracking, and libraries.
The resolution of a barcode is dependent on the narrowest element of a barcode (X dimension), and can vary from high density (nominally less than 0.009 in./0.23 mm), medium density (between 0.009 in./0.23 mm and
0.020 in./0.50 mm), and low density (greater than 0.020 in./0.50 mm).
Medium and low densities are the most common since these are the easiest to read (scan) with nearly all scanning devices. The scanner can read barcodes with X-dimensions as low as 5 mils (0.005 in/0.13mm).
WCS3900 Series Scanners can read the most popular barcode symbologies including Code 39, Code 93, Code 128, Interleaved 2 of 5,
UPC-A, UPC-E, EAN/JAN-8, EAN/JAN-13, Codabar, and MSI/Plessey.
Please see test chart on pages 29-31.
3
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 4
Chapter 3
Installation
WCS3900 USB Scanner
Trigger
USB Port
1. Insert the USB cable directly into your PC’s USB port.
Scanning Aperture
WCS3900 PS2 Scanner
Trigger
Scanning Aperture
Din-6M
Din-6F
1. Turn off your computer.
2. Unplug your PC keyboard cable and plug the male end (Din 6) of the WCS3900 Scanner directly into your PC keyboard port.
Plug your keyboard cable into the other end (female Din 6) of the the scanner.
3. Turn your computer on.
4
4
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 5
Chapter 4
Quick Start
Your Wasp WCS3900 Series Scanners are ready for use. The default settings of the scanners have been pre-programmed for the most common barcode configurations. Use the “Setup & Configuration” sections only to customize the scanners settings. Please review the “Enable Barcode
Symbologies” configuration beginning on page 14 to see the list of barcodes symbologies which are enabled by default.
Tip:
• Use the pre-printed "Barcode Test Symbols" in Appendix A on pages
29-31 as a test chart to practice scanning.
PS2 Connection
USB Connection
5
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 6
Chapter 5
Setup & Configuration
In order to configure Wasp WCS3900 Series Scanners, you must familiarize yourself with the setup procedures on the following pages. The default settings of the scanners are identified on each page and clearly marked using an asterisk (*). The default settings have been programmed for the most common barcode configurations. Use the setup & configuration barcodes only to customize the
WCS3900 Series Scanner settings. If you need to configure the
Scanner, the default settings will be overwritten. All the programmed settings are stored permanently in non-volatile memory; therefore, your configuration will be maintained even if the keyboard power to the
WCS3900 Series Scanners are removed by turning off your PC.
In order to configure Wasp WCS3900 Series Scanners, two basic steps need to be followed:
(1) Locate the group that contains the options to be changed.
(2) Scan the barcode representing the option to be changed.
The scanner will sound two beeps.
To change Minimum/Maximum Length:
(1) Scan the Minimum or Maximum Length barcode on page 15.
(2) Scan a 2 digit value from the ASCII table on pages 31-34
(3) Scan the Minimum or Maximum Length barcode again.
Example: To have a minimum length barcode of 1, you must scan a
0 then 1, then scan the minimum barcode again. To have a maximum length barcode of 10, you must scan a 1 then 0, then scan the maximum barcode again.
6
6
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 7
FACTORY DEFAULT & KEYBOARD CONNECTION
Chapter 5
Factory Default
Use the Factory Default barcode to reset the scanner to the Default settings.
F a c t o ry Default
Continuous Mode
Scan this continuous scan mode barcode to enable continuous scanning.
This feature allows the scanner to be used with a stand for hands free scanning. The trigger is functionless in this mode. To turn this mode off scan the default barcode above.
Continuous Scan Mode Enable
Keyboard Connection
The Keyboard Connection is used to program the Wasp WCS3900 Series scanner for the type of host computer.
PC (USB or PS/2) * N o t e b o o k
*Default
7
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 8
Chapter 5
BEEP AND DELAY
The 'Beep and Delay' configuration supports the general control options for the WCS3900 Series Scanners. These options include the volume, intercharacter delay, and interblock delay.
Interblock delay is the minimum time interval between two adjacent scans.
If the processing speed of your host device is slower than your scanning speed, a longer interblock delay may ensure the data integrity.
Intercharacter delay is the time period that the scanner will wait before transmitting the next character. If data sent by the scanner has incorrect or missing characters, a longer intercharacter delay may solve the problem.
The intercharacter delay should be changed only if the transfer rate cannot be maintained between the scanner and the keyboard buffer of the computer.
Note: The default for the intercharacter delay is set to '140us' and is the most common configuration; however, your PC may be different. When you scan a barcode, if stray or scrambled characters appear, increase the intercharacter delay to slow down the transfer rate.
Beep Settings
Beep Off Beep Hi
Beep Medium * Beep Low to High
Beep High to Low
8
Beep Low
*Default
8
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 9
BEEP AND DELAY
Chapter 5
Interblock Delay Intercharacter Delay
0ms * 140us *
1 0 0 m s
2 0 0 m s
1 0 m s
5 0 m s
5 0 0 m s
4 m s
1 6 m s
5 0 0 u s
1 m s
*Default
9
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 10
Chapter 5
UPPER/LOWER CASE
• Caps Lock Auto (For PC XT/AT only):
In Auto mode, the scanner will keep track of the Caps Lock status automatically. For some PCs, the scanning performance may be compromised because of the auto tracing. If the scanning performance is poor (or cannot scan) or the scanner cannot output the upper/lower case characters correctly, try to select one of the next two choices instead of auto tracing.
• Caps Lock Off:
When the keyboard is in the unshifted state
(Caps Lock is not pressed), select “Lower Case.”
• Caps Lock On:
When the keyboard is in the shifted state (Caps Lock is on), select “Upper Case.”
Caps Lock On
Caps Lock Off *
Caps Lock Auto
*Default
10
10
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 11
KEYBOARD LANGUAGE
Chapter 5
The ‘Keyboard Language’ setting controls the key codes for your keyboard’s language.
U.S. *
G e r m a n
F r e n c h
S p a n i s h
I t a l i a n
*Default
11
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 12
Chapter 5
PREAMBLE/POSTAMBLE CONFIGURATION
The ‘Preamble/Postamble’ configuration is used to add a prefix or suffix set of characters to the barcode value. Up to 8 characters may be added for each option separately. Preamble and postamble characters can function concurrently, but need to be configured separately.
To add preamble or postamble characters, follow the steps below:
1) Scan the ‘Clear Pre/Postamble’ barcode on this page.
2) Scan the ‘Preamble’ or ‘Postamble’ barcode.
3) Use Appendix B on pages 32-35 to locate the characters you want to add as preamble or postamble characters. Make sure that you scan the barcode associated with each letter before preceding to the next character. For example, to add the letter “A,” scan the barcode corresponding to the letter “A” on page 34. The letter “A” will always appear in your data as prefix or suffix to the barcode value.
4) Scan the corresponding 'Pre/Postamble' barcode on this page to exit this setting.
Clear Pre/Postamble
P r e a m b l e
P o s t a m b l e
12
12
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 13
TERMINATOR/CODE ID
Chapter 5
Terminator
The ‘Terminator’ option is used to specify the end-of-text message and is primarily used to denote the end of the barcode value.
CR *
N o n e
Ta b
S p a c e
L F E S C
CR + LF
Code ID
The ‘Code ID’ option sends a specific value when a particular barcode symbology is scanned. For example, if ‘Code ID’ is enabled and Code 39 is scanned, an “M” will appear in the data stream in front of the barcode value.
Code ID On
O - MSI/Plessey T - EAN 128
S - EAN 8 K - Code 128
E - UPC E
A - UPC A
F - EAN 13
N - Codabar
D - Full ASCII Code 39
M - Std. Code 39
L - Code 93 I - Interleaved 2 of 5
Code ID Off *
*Default
13
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 14
Chapter 5
Enable
ENABLE/DISABLE BARCODE SYMBOLOGIES
Disable
Enable All Disable All
MSI Plessey M S I Plessey *
Interleaved 2 of 5 *
Code 128 *
Codabar *
Code 39 *
Interleaved 2 of 5
Code 128
C o d a b a r
Code 39
*Default
14
14
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 15
ENABLE/DISABLE BARCODE SYMBOLOGIES
Chapter 5
Enable Disable
UPC A * UPC A
UPC E *
EAN 8 *
EAN 13 *
Code 93
UPC E
EAN 8
EAN 13
Code 93 *
*Default
15
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 16
Chapter 5
CODE 39 SETTINGS
Code 39 is variable length and is the most frequently used symbology in industrial barcode systems today. It is extensively used within the
Department of Defense (DOD). The principal feature is to encode messages using the full alphanumeric character set. Standard Code 39 contains only 43 characters (0-9, A-Z, $, /, %, +, -, ., SPACE) and can be extended to a 128 character symbology (full ASCII) by combining one of the special characters (S, /, %, +) with a letter (A-Z) to form the characters that are not present in the standard Code 39 symbology.
See page 6 for information on setting the minimum and maximum lengths.
Enable Code 39 * Disable Code 39
Enable Code 39
Full ASCII *
Check Digit Do
Not Calculate *
Disable Code 39
Full ASCII
Check Digit Calculate
And Send
Check Digit Calculate
But Do Not Send *
Minimum Length (1 *)
16
Maximum Length (48 *)
*Default
16
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 17
INTERLEAVED 2 OF 5 AND CODE 93 SETTINGS
Chapter 5
Interleaved 2 of 5 is a variable length, even numbered, numeric barcode.
It is typically used in industrial and master carton labeling and also in the automobile industry. The symbology uses bars to represent the first digit of a pair and the interleaved (white) spaces to represent the second digit of a character pair.
See page 6 for information on setting the minimum and maximum lengths.
Enable Interleaved
2 of 5 *
Disable Interleaved
2 of 5
Check Digit Calculate
And Send
Check Digit Do
Not Calculate *
Check Digit Calculate
But Do Not Send
Minimum Length (6 *) Maximum Length (48 *)
Code 93 encodes the full 128 ASCII character set using 9 modules arranged into 3 bars with adjacent spaces. Two of the characters are check characters. Code 93 is similar to Code 39 but encodes more characters per inch.
Enable Code 93 Disable Code 93 *
Minimum Length (6 *)
17
Maximum Length (48 *)
*Default
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 18
Chapter 5
CODE 128 AND UCC/EAN 128 SETTINGS
Code 128 is the most flexible of all the common linear symbologies.
It supports alpha and numeric characters easily, has the highest number of characters per inch, and is variable length.
See page 6 for information on setting the minimum and maximum lengths.
Enable Code 128 * Minimum Length (5 *)
Disable Code 128 Maximum Length (48 *)
UCC/EAN 128
Enable *
UCC/EAN 128
Code ID Enable
UCC/EAN 128
D i s a b l e
UCC/EAN 128
Code ID Disable *
Function 1
Character Send
Define UCC/EAN 128
Group Separator
Function 1
Character Do Not Send *
To Define UCC/EAN 128 Group Separator:
1. Scan Define UCC/EAN 128 Group Separator
2. Scan ASCII code from pages 31-34
3. Scan Define UCC/EAN 128 Group Separator
Note: Default Group Separator is GS
*Default
18
18
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 19
MSI PLESSEY SETTINGS
Chapter 5
MSI Plessey is a variable length numeric symbology and is primarily used in marking retail shelves. Each character consists of four bars with intervening spaces for each encoded digit, one or two symbol check digits, and a reverse start code.
See page 6 for information on setting the minimum and maximum lengths.
E n a b l e Disable *
Check Digit Ve r i f y
And Send *
Check Digit Ve r i f y
And Do Not Send
Check Digit Double
MOD 10
Check Digit Single MOD 10
Check Digit Double 11
Plus MOD 10
Minimum Length (6 *)
19
Maximum Length (48 *)
*Default
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 20
Chapter 5
CODABAR SETTINGS
Codabar is a variable length symbology capable of encoding six special alphanumeric characters, capital letters A through D, T, N, *, E, and all numeric digits. Codabar is one of the oldest barcode symbologies and is still used in some library applications. It should not be considered for new applications except under unusual circumstances.
See page 6 for information on setting the minimum and maximum lengths.
Codabar Enable * Codabar Disable
Send Start/Stop *
Check Digit
Do Not Verify *
Check Digit Ve r i f y
And Do Not Send
Do Not Send
S t a r t / S t o p
Check Digit
Verify And Send
Minimum Length (6 *)
20
Maximum Length (48 *)
*Default
20
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 21
UPC-A SETTINGS
Chapter 5
UPC-A (Universal Product Code-A) is fixed length and is the most common UPC barcode for retail product labeling. It is seen in most grocery stores across the United States. The symbology encodes a
12-digit number. The first six digits are assigned from the Uniform Code
Council (UCC). The next five digits are assigned by the manufacturer, and the final digit is a modulo 10 check digit. The nominal height for the
UPC-A barcode is one inch. The reduced size is 80% of the nominal size.
UPC-A Enable * UPC-A Disable
Send Leading Digit *
Send Check Digit *
Do Not Send
Leading Digit
Do Not Send
Check Digit
21
*Default
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 22
Chapter 5
UPC-A SUPPLEMENT SETTINGS / UPC-A TO EAN-13
This option enables the two and five digit supplements for the UPC and
EAN/JAN barcode symbologies.
5 Digit Supplement
E n a b l e
2 Digit Supplement
E n a b l e
Transmit if Present
5 Digit Supplement
Disable *
2 Digit Supplement
Disable *
Must Be Present *
This option expands the UPC-A barcode to EAN-13.
PostScript Picture
(UPCtoEAN13_on.eps)
UPC-A to EAN-13
E n a b l e
PostScript Picture
(UPCtoEAN13_off.eps)
UPC-A to EAN-13
Disable *
*Default
22
22
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 23
UPC-E SETTINGS
Chapter 5
UPC-E (Universal Product Code-E) is fixed length and is a compressed six digit code used for marking small packages, including magazines and paperback books. UPC-E symbols are UPC-A symbols that have been zero suppressed (i.e. consecutive zeros are not included in the symbol).
The printed value of the UPC-E code is a twelve digit code. The nominal height for the UPC-E barcode is one inch. The reduced size is 80% of the nominal size.
UPC-E Enable * UPC-E Disable
Send Leading Digit *
Send Check Digit *
Do Not Send
Leading Digit
Do Not Send
Check Digit
Expand to UPC-A
O n
23
Expand to UPC-A
Off *
*Default
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 24
Chapter 5
UPC-E SUPPLEMENT SETTINGS
This option enables the two and five digit supplements for the UPC and
EAN/JAN barcode symbologies.
5 Digit Supplement
E n a b l e
2 Digit Supplement
E n a b l e
Transmit if Present
5 Digit Supplement
Disable *
2 Digit Supplement
Disable *
Must Be Present *
24
*Default
24
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 25
EAN-8 SETTINGS
Chapter 5
The EAN/JAN-8 is fixed length and is similar to the UPC-E code, but includes two more digits for the country code. The nominal height for the EAN/JAN-8 barcode is one inch. The reduced size is 80% of the nominal size.
EAN-8 Enable * EAN-8 Disable
Send Leading Digit *
Send Check Digit *
Do Not Send
Leading Digit
Do Not Send
Check Digit
25
*Default
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 26
Chapter 5
EAN-8 SUPPLEMENT SETTINGS
This option enables the two and five digit supplements for the UPC and
EAN/JAN barcode symbologies.
5 Digit Supplement
E n a b l e
2 Digit Supplement
E n a b l e
Transmit if Present
5 Digit Supplement
Disable *
2 Digit Supplement
Disable *
Must Be Present *
26
*Default
26
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 27
EAN-13 SETTINGS
Chapter 5
The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology, but encodes a
13th digit. The nominal height for the EAN/JAN-8 barcode is one inch.
The reduced size is 80% of the nominal size.
EAN-13 Enable * EAN-13 Disable
Send Leading Digit *
Send Check Digit *
ISBN Enable
Do Not Send
Leading Digit
Do Not Send
Check Digit
ISBN Disable *
ISSN Enable
27
ISSN Disable *
*Default
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 28
Chapter 5
EAN-13 SUPPLEMENT SETTINGS
This option enables the two and five digit supplements for the UPC and
EAN/JAN barcode symbologies.
5 Digit Supplement
E n a b l e
2 Digit Supplement
E n a b l e
Transmit if Present
5 Digit Supplement
Disable *
2 Digit Supplement
Disable *
Must Be Present *
28
*Default
28
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 29
BARCODE TEST SYMBOLS
Appendix A
Note: Make sure that the appropriate barcode symbology is configured properly and enabled before trying to scan. Use the 'Barcode Symbologies' configuration beginning on page 14 to enable specific symbologies.
Code 39*
Code 93
Interleaved 2 of 5 *
Codabar *
Code 128*
MSI/Plessey
*Default
29
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 30
Appendix A
BARCODE TEST SYMBOLS
UPC-A*
UPC-A w/5 digit supplement
UPC-A w/2 digit supplement
UPC-E*
UPC-E w/5 digit supplement
UPC-E w/2 digit supplement
*Default
30
30
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 31
BARCODE TEST SYMBOLS
Appendix A
EAN/JAN-13*
EAN/JAN-13 w/5 digit supplement
EAN/JAN-13 w/2 digit supplement
EAN/JAN-8*
EAN/JAN-8 w/5 digit supplement
EAN/JAN-8 w/2 digit supplement
*Default
31
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 32
Appendix B
ASCII TABLE
Use this ASCII Table to add preamble and postamble characters to your barcode value. Please refer to the appropriate configuration section for the number of characters that can be configured.
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
FF
CR
LF
VT
SO
SI
DLE
DC1
DC2
DC3
32
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
32
"
#
SP
!
RS
US
$
%
&
(
'
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 33
ASCII TABLE
Appendix B
;
:
<
=
>
8
9
6
7
4
5
.
-
/
0
1
+
,
*
)
2
3
33
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 34
A
B
C
D
?
@
E
F
PostScript Picture
Appendix B
ASCII TABLE
H
I
N
O
P
Q
R
L
M
J
K
S
T
34
\
[
]
^
_
Y
Z
W
X
U
V
34 f g h j i d e b c
` a
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 35
ASCII TABLE
Appendix B z
{ x y v w
}
|
~
DEL l k m n o p q r s t u
35
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 36
Appendix C
FUNCTION CODE FOR PC
F1 F10 Cursor Right
F4
F5
F2
F3
F11
F12
Tab
Back Tab
Cursor Up
Cursor Left
Cursor Down
Page Up
F8
F9
F6
F7
Esc
End
Home
Back Space
36
Page Down
Ins
Enter
Del
36
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 37
TECHNICAL SPECIFICATIONS
Appendix D
MODEL
OPTICAL
Scanning Width
Depth of Field
Scan Rate
Decode Rate
ELECTRICAL
Light Sourc e
S e n s o r
Operating Vo l t a g e
Current Consumption
O u t p u t
MECHANICAL
D i m e n s i o n s
We i g h t
C a b l e
H o u s i n g
ENVIRONMENTAL
Operating Te m p e r a t u r e
Storage Te m p e r a t u r e
Relative Humidity
Safety Certification
WCS3900
3.00” (76mm) contact to 5mm (approx 1.5”)
45 scans / second
100 scans / second
660 nm red visible LED
2088 linear imager
+5 VDC ± 5%
Decoded: Standby
<30 mA/ Working <95 mA
USB or PS/2
L7.40” x W3.62” x H1.06”
125 g (without cable)
6 ft
A B S
0˚C to 50˚C
-20˚C to 60˚C
20% to 80% non-condensing
Conforms FCC Class A and
CE requirements
37
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 38
Warranty Information
Wasp Barcode Technologies products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions.
This warranty is limited to repair or replacement at Wasp Barcode
Technologies option, with reasonable promptness after being notified.
These provisions do not prolong the original warranty term for any product which has been repaired or replaced by Wasp Barcode
Technologies.
This warranty applies to the original owner and does not extend to any product which has been subject to misuse, neglect, accidental damage, unauthorized repair, or tampering.
No other express warranty is given. The replacement or repair of a product is your exclusive remedy. Any other implied warranty of merchantability or fitness is limited to the duration of this written warranty.
Some states, provinces, and countries do not allow limits on how long an implied warranty lasts, so the above limitation may not apply to you.
In no event shall Wasp Barcode Technologies be liable for consequential damages. Some states, provinces, and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.
38
38
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 39
FAQ
Q: How do I configure the scanner for a notebook (or laptop) computer?
A: Scan the “Notebook” barcode on page 7.
Q: How do I change the terminator to a Tab?
A: Scan the “Tab” barcode on page 13.
Q: How do I remove the terminator?
A: Scan the “None” barcode on page 13.
Q: How do I enable the Full ASCII character set for the Code 39 barcode symbology?
A: Scan the following “Enable Code 39 Full ASCII” barcode on page 14.
39
WCS3900_3905Manual0707_sm.A0 6/25/08 4:32 PM Page 40
Product Support
If you experience any problems with the Wasp WCS3900 Series
Scanners that you are unable to resolve, call for technical assistance at
(214) 547-4100 ext 2, Monday through Friday, 8:00 AM - 5:00 PM Central
Standard Time. Visit www.waspbarcode.com/support anytime.
40
CCD Scanner Programming Guide
Please Read
Note: The Wasp
®
WCS3900 Series Scanners are ready to scan the most popular barcodes out of the box.
This manual should only be used to make changes in the
configuration of the scanner for specific applications. These scanners do not require software or drivers to operate. The scanner enters data as keyboard data. Please review this manual before scanning any of the programming barcodes in this manual.
Tech Tip
If you are unsure of the scanner configuration or have scanned the incorrect codes, please scan the default barcode on page 7.
This will reset the scanner to its factory settings.
Check Version
© Copyright Wasp Barcode Technologies 2007
No part of this publication may be reproduced or transmitted in any form or by any means without the written permission of Wasp Barcode Technologies. The information contained in this document is subject to change without notice.
Wasp and the Wasp logo are registered trademarks of Wasp Barcode Technologies. All other trademarks or registered trademarks are the property of their respective owners.
Wasp Barcode Technologies
Productivity Solutions for Small Business that
Increases Productivity & Profitability
• Barcode, data collection solutions
• Small business focus
• Profitable growth since 1986
• Over 200,000 customers
• Business unit of Datalogic SPA
Wasp ® Barcode Technologies
1400 10th Street
Plano, TX 75074
Phone: 214-547-4100 • Fax: 214-547-4101 www.waspbarcode.com
Barcode Scanning Made Easy
Wasp Barcode Technologies
1400 10th Street
Plano, TX 75074 www.waspbarcode.com
0707US
Programming Guide
Download
Advertisement
Key features
Supports popular barcode symbologies (Code 39, Code 128, UPC-A, etc.)
Easy configuration via programming barcodes
Rugged design with no moving parts
USB or PS/2 connectivity
Adjustable beep volume and delay settings
Preamble/postamble configuration for adding prefixes/suffixes
Terminator options (CR, Tab, etc.)
Code ID feature to identify scanned symbologies
Frequently asked questions
Scan the “Notebook” barcode on page 7.
Scan the “Tab” barcode on page 13.
Scan the “None” barcode on page 13.
Scan the “Enable Code 39 Full ASCII” barcode on page 14.