® AP1400R

Dual Pentium ® III 1U Rackmount Server

User’s Manual

Disclaimer/Copyrights

No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER

INC. (“ASUS”).

ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND,

EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED

WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS DIRECTORS,

OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL,

INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR

LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA,

INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN

ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY

DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.

Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by

ASUS; or (2) the serial number of the product is defaced or missing.

Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’ benefit, without intent to infringe.

The product name and revision number are both printed on the product itself. Manual revisions are released for each product design represented by the digit before and after the period of the manual revision number. Manual updates are represented by the third digit in the manual revision number.

For previous or updated manuals, BIOS, drivers, or product release information, contact

ASUS at http://www.asus.com.tw or through any of the means indicated on the following page.

SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE

FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE

AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A

COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY

FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL,

INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.

Copyright © 2001 ASUSTeK COMPUTER INC. All Rights Reserved.

2

Product Name: AP1400R

Manual Revision: 1.00 E628

Release Date: March 2001

ASUS Contact Information

ASUSTeK COMPUTER INC. (Asia-Pacific)

Marketing

Address:

Telephone:

Fax:

Email:

150 Li-Te Road, Peitou, Taipei, Taiwan 112

+886-2-2894-3447

+886-2-2894-3449 [email protected]

Technical Support

Tel (English): +886-2-2890-7123

Tel (Chinese): +886-2-2890-7113

Fax:

Email:

Newsgroup:

+886-2-2893-7775 [email protected]

news2.asus.com.tw

WWW:

FTP: www.asus.com.tw

ftp.asus.com.tw/pub/ASUS

ASUS COMPUTER INTERNATIONAL (America)

Marketing

Address:

Fax:

Email:

6737 Mowry Avenue, Mowry Business Center, Building 2

Newark, CA 94560, USA

+1-510-608-4555 [email protected]

Technical Support

Fax:

BBS:

Email:

WWW:

FTP:

+1-510-608-4555

+1-510-739-3774 [email protected]

www.asus.com

ftp.asus.com.tw/pub/ASUS

ASUS COMPUTER GmbH (Europe)

Marketing

Address:

Fax:

Email:

Harkortstr. 25, 40880 Ratingen, BRD, Germany

+49-2102-442066 [email protected] (for marketing requests only)

Technical Support

Hotline: MB/Others: +49-2102-9599-0

Notebook: +49-2102-9599-10

Fax: +49-2102-9599-11

Support (Email): www.asuscom.de/de/support (for online support)

WWW:

FTP: www.asuscom.de

ftp.asuscom.de/pub/ASUSCOM

3

4

FCC/CDC Statements

Federal Communications Commission Statement

This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:

• This device may not cause harmful interference, and

• This device must accept any interference received including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a

Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer’s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

WARNING! The use of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Canadian Department of Communications Statement

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

This class B digital apparatus complies with Canadian ICES-003.

Safet y Precautions

Safeguards

Observe the following safety precautions when you are connecting or disconnecting any devices.

Operation Safety

IMPORTANT

• Any operation on this server must be conducted by certified or experienced engineers.

• Before operating your server, carefully read all the manuals included with the server package.

• Before using the server, make sure all cables are correctly connected and the power cables are not damaged. If any damage is detected, contact your dealer as soon as possible.

• To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry.

• Before opening the chassis panels, make sure all power cables are unplugged.

• Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.

• If the power supply is broken, do not try to fix it by yourself. Contact an authorized dealer.

• It is recommanded that you wear gloves when assembling or dissembling the server to protect from cuts and scrapes.

• When the server is powered on, heat sinks and the surfaces of certain IC devices may be hot. Do not touch them. Check whether the fans are functioning properly.

Tools Required

You need a Philips (cross) screwdriver and a flat screwdriver to install or remove the components in the server.

5

6

Safet y Precautions

Electrical Safety

IMPORTANT

• Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged.

• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system.

• When adding or removing any additional devices to or from the system, ensure that the power cables for those devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.

• Use one hand, when possible, to connect or disconnect signal cables to prevent a possible shock from touching two surfaces with different electrical potentials.

CAUTION

This product is equipped with a three-wire power cable and plug for the user’s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock.

IMPORTANT

Motherboards, adapters, and disk drives are sensitive to static electricity discharge. These devices are wrapped in antistatic bags to prevent this damage. Take the following precautions:

• If you have an antistatic wrist strap available, use it while handling the device.

• Do not remove the device from the antistatic bag until you are ready to install the device in the system unit.

• With the device still in its antistatic bag, touch it to a metal frame of the system.

• Grasp cards and boards by the edges. Hold drives by the frame. Avoid touching the solder joints or pins.

• If you need to lay the device down while it is out of the antistatic bag, lay it on the antistatic bag. Before picking it up again, touch the antistatic bag and the metal frame of the system unit at the same time.

• Handle the devices carefully to prevent permanent damage.

Contents

Introduction: About This Manual .................................. 9

Audience ..................................................................................... 10

Contents Description ................................................................. 10

Conventions ................................................................................. 11

Symbols ................................................................................... 11

Package Contents ...................................................................... 12

Standard Components ............................................................ 12

Optional Components ............................................................. 12

Chapter 1: System Overview ...................................... 13

Features ...................................................................................... 14

Chassis: ASUS AR-10 ............................................................ 14

Motherboard: ASUS CUR-DLSR ............................................ 14

Front Panel .................................................................................. 15

Back Panel .................................................................................. 15

Power Button and System LEDs ............................................... 16

LED Information ...................................................................... 16

Chapter 2: Basic Operation ........................................ 17

Getting Started ........................................................................... 18

Monitor Connection ................................................................. 18

Power Connection .................................................................. 18

Power ON ............................................................................... 18

Check LED .............................................................................. 18

Chapter 3: Hardware Setup ........................................ 19

Opening the Chassis .................................................................. 20

Unlocking the Cover ............................................................... 20

Removing the Cover ............................................................... 21

Internal Components ................................................................. 22

Motherboard Placement ............................................................ 23

Placement Direction ................................................................ 23

Motherboard Screws ............................................................... 23

Central Processing Unit (CPU) .................................................. 24

CPU Orientation ...................................................................... 24

CPU Socket Locations ............................................................ 24

CPU Installation ...................................................................... 25

CPU Heatsink .............................................................................. 26

Attaching the Heatsink Front Clip ........................................... 26

Attaching the Heatsink Back Clip ............................................ 26

7

8

Contents

CPU Terminator .......................................................................... 27

CPU Fan Cable ............................................................................ 27

Connecting the Fan Cable ...................................................... 27

CPU Blower and Tube ................................................................ 28

CPU Blower and Tube Location .............................................. 28

Cooling Fans ............................................................................... 29

System Memory .......................................................................... 29

DIMM Sockets Location .......................................................... 29

DIMM Installation .................................................................... 30

Riser Card / Expansion Card ..................................................... 31

Installing an Expansion Card .................................................. 31

Securing the Expansion Card ................................................. 32

Securing an Extended PCI Card ............................................. 32

SCSI Backplane .......................................................................... 33

Front Side ............................................................................... 33

Back Side ................................................................................ 33

Connecting Cables ..................................................................... 34

SCSI Cable ............................................................................. 34

IDE Cable ............................................................................... 34

Floppy Cable ........................................................................... 35

LED Cable .............................................................................. 35

Power Cables ......................................................................... 36

Cooling Fan Cables ................................................................ 36

CD-ROM Drive ............................................................................. 37

CD-ROM Mounting ................................................................. 37

CD-ROM Adapter Board ......................................................... 38

CD-ROM Installation ............................................................... 38

Floppy Drive ................................................................................ 39

Floppy Drive Mounting ............................................................ 39

Floppy Drive Installation ......................................................... 39

SCSI Hard Disk Drives ............................................................... 40

Hot-Swap Drive Tray ............................................................... 40

SCSI HDD Mounting ............................................................... 40

HDD Installation ...................................................................... 41

System Power Supply ................................................................ 42

Power Supply Specifications .................................................... 43

Output Voltage Regulation ...................................................... 43

Output Current Capacity ......................................................... 43

Over-Voltage Protection (OVP) ............................................... 43

Introduction

You are reading the AP1400R Server

User’s Manual. This manual provides genaral and specific information about the AP1400R server.

“About This Manual” contains an introduction on the contents of this document that include target audience, chapter description, and conventions used. It also lists the items included in the system package.

AP1400R Server User’s Manual 9

Audience

This manual is intended for experienced users and integrators with hardware knowledge of personal computers.

Contents Description

This manual contains the following parts:

1. Introduction: About This Manual

This part contains an introduction on the contents of this document that include target audience, chapter description, and conventions used. It also lists the items included in the system package.

2. Chapter 1: System Overview

This chapter describes the external features of the AP1400R server. It includes specific sections that identify these features.

3. Chapter 2: Basic Operation

This chapter tells how to get started with the AP1400R server.

The basic operation includes connecting the cables and powering on the system.

4. Chapter 3: Hardware Setup

This chapter describes the hardware setup procedures that you have to perform when installing system components. It also gives detailed information on the internal components and how to install them.

10 Introduction: About This Manual

Conventions

Symbols

To make sure that you perform certain tasks properly, take note of the following symbols used throughout this guide.

WARNING: Information to prevent injury to yourself when trying to complete a task.

CAUTION: Information to prevent damage to the components when trying to complete a task.

IMPORTANT: Information that you MUST follow to complete a task.

NOTE: Tips and information to aid in completing a task.

PHILIPS (CROSS) SCREW DRIVER: A tool required to install or remove the components in the server.

STANDARD (FLAT) SCREW DRIVER: A tool required to install or remove the components in the server.

STEP: Actions to complete a task.

AP1400R Server User’s Manual 11

Package Contents

This section lists the items included in the server package.

Standard Components

Motherboard

Chassis

Power Supply

Processor (CPU)

Memory Modules

Hard Drive

Floppy Drive

CD-ROM Drive

PCI Riser Card

SCSI Cable

S370 CPU Terminator

Rackmount Rails

User’s Manuals

CUR-DLSR

AR-10 1U Rackmount

200W

Pentium ® III up to 1GHz

64, 128, 256, 512MB, 1GB SDRAM

80-pin SCA-2 Ultra160 SCSI interface

Slim-type 1.44MB

Slim-type 24X

64-bit/33MHz PCI slot

AR-10 rail kit

CD-ROM, motherboard

Optional Components

RAID Controller ASUS PCI-DA2200 RAID controller

12 Introduction: About This Manual

Chapter 1

This chapter describes the external features of the AP1400R server. It includes specific sections that identify these features.

AP1400R Server User’s Manual 13

14

Features

The AP1400R is configured for the ASUS CUR-DLSR smart motherboard that uses the ServerSet TM chipset from ServerWorks ®.

The motherboard supports dual Pentium III processors to accelerate even the most complicated server tasks. The following are highlights to the server’s many features. For additional information, refer to the

CUR-DLSR User’s Manual.

Chassis: ASUS AR-10

Chassis: 1U form factor that fits in a standard 19” rack

SCSI Backplane: Supports three SCSI hard drives using 80pin SCA-2 connectors

Power: Pinot 200W single power supply equipped with universal

AC input and ATX-compliant output cables

Device Bays: Support for one 3.5-inch slim type floppy device, one 5.25-inch slim type CD-ROM drive, and three 3.5-inch wide

1-inch high hot-swappable SCA SCSI hard disk drives in removable trays

Motherboard: ASUS CUR-DLSR

Processor: Dual Intel ® Pentium III FC-PGA processors running up to 1GHz

Memory: Four 168-pin DIMM sockets that support up to 4GB

PC133 registered SDRAM with ECC support

Onboard SCSI: LSI ® 53C1010-33 dual-channel Ultra160 SCSI controller that supports up to 30 SCSI devices using two 68-pin

Wide SCSI connectors

Onboard LAN: Dual Intel ® 82559 Fast-Ethernet server controllers that supports 10BASE-T and 100BASE-TX, RJ-45 output

Onboard VGA: ATI ® Rage XL VGA controller with 4MB PC100

SDRAM

Integrated Super I/O: PC97317 controller that supports one floppy drive, two serial ports, one printer port, two USB ports, one PS/2 keyboard, and one PS/2 mouse

Expansion Slot: One full-length 64-bit/33MHz PCI slot on riser card

Chapter 1: System Overview

Front Panel

The front panel of the AP1400R server allows easy access to the floppy, CD-ROM, and removable hard disk drives. The power button and the system LED indicators are also located on the front panel

(see next page for descriptions).

CD-ROM Drive Floppy Drive

System LEDs

HDD0 Drive Bay HDD1 Drive Bay HDD2 Drive Bay

Back Panel

The server back panel includes the connectors the system devices and a slot for an expansion card.

1 2 3 4 5 6 7 8 9 10 11

1. AC Power Connector

2. PS/2 Keyboard Port

3. PS/2 Mouse Port

4. USB Ports 1 and 2

5. Serial Port (COM1)

6. Printer Port

7. VGA Port

8. LAN1 Port (RJ-45)

9. LAN2 Port (RJ-45)

10. Expansion Slot

11. High-Density SCSI Connector

AP1400R Server User’s Manual 15

Power Button and System LEDs

The chassis includes system LEDs to indicate fan and thermal status, hard disk status, and system power status.

1 2 3 4 5 6 7 8 9 10

16

1. Reset Switch

2. Fan Fail LED

3. Temperature LED

4. HDD0 Status LED

5. HDD1 Status LED

6. HDD2 Status LED

7. Hard Disk Activity LED

8. Power LED

9. Power Button

10. Programmable Message LED

LED Information

Fan Fail LED

When the fan speed is normal, this LED is ON (steady green). The

LED turns to steady red when the fan speed crosses a critical threshold.

Temperature LED

When the system temperature is normal, this LED is ON (steady green). The LED turns to steady red when the system temperature crosses a critical threshold.

SCSI HDD Drive Status LEDs

The SCSI hard disks have individual LEDs. When a hard disk is installed, the specific LED for that hard disk is ON (steady green) under normal conditions. When the disk becomes faulty, the LED turns to steady red. The HDD LED is unlit when there is no hard disk present.

HDD Activity LED

This LED flickers (green) whenever there is an IDE/SCSI HDD activity.

This LED is unlit when there is no disk activity.

Power LED

This LED lights up (steady green) when you apply power to the system by pressing the power button. This LED goes off when you turn off the system.

Message LED

This LED is software programmable to indicate conditions such a power outage.

Chapter 1: System Overview

Chapter 2

This chapter tells how to get started with the AP1400R server. The basic operation includes connecting the cables and powering on the system.

AP1400R Server User’s Manual 17

18

Getting Star ted

Before you turn on the server, make sure that you have completed the basic system connections. Follow these steps when starting the server.

Monitor Connection

Connect a monitor by plugging a video cable to the video port (blue port) at the back of the server.

Video Port

Power Connection

Connect a power cord to the AC power connector at the back of the server, then plug the power cord to a grounded wall socket.

AC Power Connector

Power Button

Power ON

Turn on the server by pressing the power button on the front panel.

Power LED

Check LED

After turning on the power, check if the power LED lights up.

Chapter 2: Basic Operation

Chapter 3

This chapter describes the hardware setup procedures that you have to perform when installing system components. It also gives detailed information on the internal components and how to install them.

AP1400R Server User’s Manual 19

Opening the Chassis

The AP1400R chassis is a 1U form factor designed for easy assembly and disassembly, making the installation of internal components very convenient. At the top of the chassis is a rotating lock that secures the cover to the chassis.

20

Rotating Lock

Unlocking the Cover

To unlock the cover, turn the rotating lock clockwise until the triangle mark points to

OPEN.

CLOSE

Triangle Mark

OPEN

Chapter 3: Hardware Setup

Opening the Chassis

Removing the Cover

Slide the top cover toward the front for about an inch, then lift it from the chassis.

CAUTION

The top cover of the chassis has locking tabs at the rear end that connect to the inner side of the back panel. Make sure to disengage the locking tabs before lifting up the cover.

AP1400R Server User’s Manual 21

Internal Components

The AP1400R server interior comprise the motherboard and other parts that complete the system.

1 2 3

13

12 11

1. Power Supply

2. CPU Blower

3. SCSI Backplane Board

4. Floppy Drive

5. SCSI Hard Disk Bay 2

6. SCSI Hard Disk Bay 1

7. Slim CD-ROM Drive

4 (Top)

5 (Bottom)

6

10 9

8. SCSI Hard Disk Bay 0

9. Memory Fan

10. Expansion Card Fan

11. Expansion Card (optional)

12. Riser Card Holder

13. CUR-DLSR Motherboard

7 (Top)

8 (Bottom)

22 Chapter 3: Hardware Setup

Motherboard Placement

This section tells how the motherboard is placed into the chassis in case you need to remove and re-install it in the future.

NOTE

The motherboard and other internal components of the

AP1400R server are already installed as indicated in the section “Internal Components” . Refer to the motherboard user’s manual for detailed technical information about the motherboard.

Placement Direction

When installing the motherboard, make sure that you place it into the chassis correctly. The edge with the external ports goes to the back panel of the chassis.

Back Panel

Motherboard Screws

Place 11 screws in the holes indicated by circles to secure the motherboard to the chassis. Do not overtighten the screws.

Doing so may damage the motherboard.

The two holes marked by solid white circles are for securing the CPU fan tube.

AP1400R Server User’s Manual 23

24

Central Processing Unit (CPU)

The CUR-DLSR motherboard has two ZIF Socket 370. Each socket supports one Intel Pentium III processor. The figure below shows the

CPU sockets on the motherboard. (NOTE: The CPU sockets are underneath the CPU blower tube. Detach the tube to locate the sockets.)

CPU Socket Locations

Socket for CPU 2

Socket for CPU 1

CPU Orientation

A CPU has a mark (usually a notch or a gold mark) on one corner to help you identify the proper orientation and enable you to correctly install the CPU.

Match the marked corner of the

CPU with the marked corner on the socket to avoid damaging the CPU pins.

Gold Mark

Chapter 3: Hardware Setup

Central Processing Unit (CPU)

CPU Installation

1. Unlock the socket by pressing the lever sideways then lifting it up to a 90°-100° angle. See

Figure 1.

2. Position the CPU above the socket such that its notched or marked corner matches the socket corner near the end of the lever, while making sure that the CPU is parallel to the socket. See Figure 2.

3. Carefuly insert the CPU into the socket until it fits in place.

4. When the CPU is in place, press it firmly on the socket while you push down the socket lever to secure the

CPU. The lever clicks on the socket indicating that it is locked.

Figure 1

Figure 2

Gold Mark Marked Corner

IMPORTANT

The CPU fits only in one orientation. Do not force the CPU into the socket to prevent bending the pins and damaging the CPU. If the CPU does not fit completely, check its orientation or check for bent pins.

AP1400R Server User’s Manual 25

CPU Heatsink

Attaching the Heatsink Front Clip

Place the heatsink on top of the installed

CPU. Attach the heatsink front clip to the front of the CPU socket.

(NOTE: When viewed from the front, the CPU socket has the lever on the right side.)

Heatsink Front Clip Socket Lever

Attaching the Heatsink Back Clip

Use a flat screwdriver to attach the back clip to the back of the CPU socket until it snaps in place.

26 Chapter 3: Hardware Setup

CPU T erminator

When using only one processor socket, make sure to install an S370 processor terminator to the unused socket. Install a CPU terminator as you would install a CPU. Refer to the section

“CPU Installation”

.

CPU Socket 2 with

Installed Terminator

CPU Socket 1 with

Installed CPU and

Heatsink

CPU Fan Cable

Connecting the Fan Cable

Connect the CPU fan (blower) cable to the connector on the motherboard.

Fan Connector on the Motherboard

AP1400R Server User’s Manual 27

CPU Blower and Tube

To maintain the ideal temperature for the CPUs, the chassis includes a 9-cm CPU blower. The blower has an extended tube directed to the two CPUs. The blower cable connects to the CPU_FAN2 connector on the motherboard.

CPU Blower and Tube Location

Three screws (indicated by white circles) secure the CPU blower to the base of the chassis. The blower tube extends to the CPU area on the motherboard and is secured by two screws as indicated in the picture by solid white circles.

These two screws have spacers underneath to allow clearance from the motherboard components.

28

Tube 9-cm CPU Blower

IMPORTANT

Detach the blower tube by removing the two securing screws to access the CPU and DIMM sockets.

Chapter 3: Hardware Setup

Cooling Fans

Subdividing the motherboard area and the disk drive area is a metal bracket that holds the cooling fans. These fans maintain the ideal temperature for the system memory and the expansion card. The fan cables connect to CHA_FAN1 and CHA_FAN2 on the motherboard.

A fan fail LED on the front panel indicates if a fan fails while another

LED indicates a thermal failure.

Memory Fan Expansion Card Fan

Metal Bracket Connect to

CHA_FAN1 on the M/B

Connect to

CHA_FAN2 on the M/B

System Memor y

The motherboard has four Dual Inline Memory Module (DIMM) sockets that support 3.3V Synchronous Dynamic Random Access Memory

(SDRAM) modules in 16, 32, 64, 128, 256, 512MB, or 1GB densities.

DIMM Sockets Location

Locate the DIMM sockets on the motherboard to install memory modules.

DIMM Sockets

AP1400R Server User’s Manual 29

System Memor y

DIMM Installation

1. Unlock a DIMM socket by pressing the retaining clips outward. Align a DIMM on the socket such that the notches on the DIMM

(indicated by white circles on the figure) match the breaks on the socket.

DIMM Socket Retaining Clip

2. Carefully insert the DIMM on the socket until the retaining clips snap back in place.

DIMM Notches

30

CAUTION

DIMMs fit in only direction. DO NOT force a DIMM into the socket to avoid damaging the DIMM.

Chapter 3: Hardware Setup

Riser Card / Expansion Card

The motherboard has a 64-bit/33MHz PCI expansion slot. The slot requires a PCI riser card (P64-1U) to accommodate a PCI expansion card. The riser card comes with the system package.

The riser card golden fingers connect to the PCI slot on the motherboard. The card has a PCI card connector for connecting a

PCI expansion card.

Golden Fingers PCI Card Connector

Installing an Expansion Card

Carefully insert the golden fingers of the PCI expansion card to the connector on the riser card. Insert the golden fingers of the riser card to the PCI slot on the motherboard until it fits in place.

Expansion Card

Riser Card

Locking Tab

PCI Slot

AP1400R Server User’s Manual 31

32

Riser Card / Expansion Card

Securing the Expansion Card

When the card is installed, push down the locking tab to firmly fix the card in place. Replace the riser card holder to secure the riser and the installed card to the chassis.

Locking Tab

Riser Card Holder

Securing an Extended PCI Card

If you are installing an extended PCI card, such as a

RAID card, pull up the the metal card holder before installing the card. When the card is in place, push down the card holder to secure the other end of the card.

Card Holder

Chapter 3: Hardware Setup

SCSI Backplane

The 1-inch high SCSI backplane included in the system supports three Ultra160 SCSI devices. The backplane design incorporates a hot-swap feature to allow easy installation of external SCSI hard disks.

The LED connector on the backplane connects to the front panel

LEDs to indicate HDD access, HDD failure, thermal failure, and fan failure.

Front Side

The front side of the backplane has three 80-pin SCA SCSI

Out connectors available for the SCA SCSI hard disks. The hard disks are extenally accessible from the front panel.

SCSI Out

HDD0

SCSI Out

HDD1

SCSI Out

HDD2

Back Side

The back side of the backplane include the power, SMB, LED, and SCSI In connectors.

Backplane Power

Connector SCSI In Connector

LED Connector SMB Connector

NOTE

The SCSI backplane is already installed in the system chassis. You do not need to remove the backplane when installing components or connecting cables.

AP1400R Server User’s Manual 33

34

Connecting Cables

SCSI Cable

Connect the 68-pin SCSI cable to the SCSI connector on the motherboard and the other end to the SCSI In connector on the backplane board.

IDE Cable

Connect one end of the

IDE cable to connector labeled IDE1 on the motherboard. Connect the other end of the cable to the IDE connector on the

CD-ROM adapter board.

SCSI Connector on the Motherboard

SCSI Connector on the Backplane

IDE1 Connector on the Motherboard

IDE Connector on the CD-ROM Adapter

Board

Chapter 3: Hardware Setup

Connecting Cables

Floppy Cable

Connect the floppy cable directly to the floppy drive connector.

Floppy Drive Connector

LED Cable

Connect one end of the

LED cable to the PANEL2 connector on the motherboard and the other end to the LED connector on the backplane board.

(Refer to the section

“SCSI

Backplane”

and to the

CUR-DLSR User ’s

Manual for details on LED connector.)

LED Connector on the Motherboard

LED Connector on the Backplane

AP1400R Server User’s Manual 35

36

Connecting Cables

Power Cables

Connect the ATX power cable to the ATX power connector on the motherboard. Connect the

4-pin power cable to the power connector on the backplane. Refer to the section

“System Power

Supply”

for details on power cables.

Power Connector on the Motherboard

Power Connector on the Backplane

Cooling Fan Cables

Connect the memory fan cable and card fan cable to their respective connectors on the motherboard.

Memory Fan

Connector

CHA_FAN1

Expansion Card

Fan Connector

CHA_FAN2

Chapter 3: Hardware Setup

CD-ROM Drive

The system chassis supports a slim CD-ROM drive. The CD-ROM bay is on top of the SCSI HDD0 drive bay (leftmost bay when facing the front panel).

CD-ROM Mounting

Place a slim CD-ROM drive to the drive tray and secure it using four screws in the areas indicated by circles.

Attach a CD-ROM adapter board to the back of the slim CD-ROM using two screws.

Drive Tray Guide Tab

Power Connector

IDE Connector CD-ROM Adapter Board

AP1400R Server User’s Manual 37

38

CD-ROM Drive

CD-ROM Adapter Board

One side of the CD-ROM adapter board has a special connector that matches the connector on the slim CD-ROM drive.

Two screw holes are available for securing the board to the CD-ROM drive. DO NOT overtigthen the screws to avoid damaging the board.

On the other side of the board, a power connector and a standard IDE connector are available.

Slim CD-ROM Connector

Power

Connector

Screw Holes

IDE Connector

CD-ROM Installation

Place the CD-ROM drive on its bay and slide it inward for about an inch

(as indicated by the arrow), making sure that the drive tray guide tab locks in place.

Secure the drive to the chassis with two screws on the areas indicated by circles. Connect the IDE and power cables to the connectors on the adapter board.

Chapter 3: Hardware Setup

Floppy Drive

The system comes with the floppy drive already installed. Refer to this section when you need to replace the floppy drive.

Floppy Drive Mounting

Place the floppy drive to the drive tray and secure it with four screws on the areas indicated by circles.

Floppy Drive Installation

Place the floppy drive on its bay (top of the SCSI

HDD2). Secure the drive to the chassis with two screws on the areas indicated by circles.

Connect the floppy disk cable to the back of the floppy drive and the other end to the floppy drive connector on the motherboard.

AP1400R Server User’s Manual 39

SCSI Hard Disk Drives

The system comes with three externally accessible hard disk drive bays.

Hot-Swap Drive Tray

In each of the HDD bays is a hot-swap tray for mounting a hard disk drive. Flip open the tray levers to release the tray, then slide the tray out of the chassis.

40

Tray Levers

IMPORTANT

Take note of the drive tray orientation before you slide it out.

The tray will not fit back into the bay if you insert it the wrong way.

SCSI HDD Mounting

Place the SCSI hard disk drive to the hot-swap drive tray and secure it with four screws as shown. Ensure the correct drive tray orientation before installing the HDD.

Chapter 3: Hardware Setup

SCSI Hard Disk Drives

HDD Installation

After the drive is secured to the tray, carefully insert the drive into the bay, then push the levers back in place.

IMPORTANT

Make sure that the SCSI cable is connected to the motherboard and the backplane. Refer to the section

“Connecting Cables” .

AP1400R Server User’s Manual 41

42

System Power Supply

The system comes with a Pinot 200W single power supply with universal AC input that includes PFC and ATX-compliant output cables and connectors. The power supply has an internal cooling fan.

The power supply has four plugs labeled P1 for ATX connector, P2 for backplane connector, P3 for CD-ROM, and P5 for fan.

Power Supply Fan

ATX Power Plug

Backplane Power Plug

CD-ROM Power Plug

Fan Power Plug

The power supply is located on the back side of the system chassis.

Power Supply

Chapter 3: Hardware Setup

Power Supply Specifications

Output Voltage Regulation

Output Voltage Min (V)

+3.3V

3.2

+5V 4.8

+12V

-12V

+5Vsb

11.4

-10.8

4.8

Nom (V) Max (V)

3.30

3.465

5.00

5.25

12.00

-12.00

5.00

12.60

-13.20

5.25

Ripple/Noise

50mV p-p

50mV p-p

120mV p-p

200mV p-p

100mV p-p

Output Current Capacity

Output Voltage Min (A)

+3.3V

0.5

+5V 0.5

+12V

-12V

+5Vsb

0.8

0.0

0.1

Max (A) Max. Load (W)

12.5

41.25

21.5

107.5

4.1

0.25

1.5

69.2

3.0

7.5

Over-Voltage Protection (OVP)

Voltage

+3.3V

+5V

+12V

Min (V)

3.8

5.7

13.5

Nom (V) Max (V)

4.1

4.3

6.25

-

6.5

15.0

AP1400R Server User’s Manual 43

This page was intentionally left blank.

44 Chapter 3: Hardware Setup

advertisement