High Volume Air Sampler
MODEL H-810
Great Sampler for Emergency Response or Temporary Portable Sampling of Air Particulates
•
HIGH ACCURACY
•
RUGGED
•
LCD DISPLAYS
Elapsed Sample Time
Flow Rate
•
•
•
Total Volume
•
MICROPROCESSOR BASED
BATTERY-BACKED
DATA MEMORY
RECESSED FLOW ADJUST
The RAD ēCO
TM
Model H-810 is a dependable, lightweight high volume air sampler which incorporates the reliability of the Model H-809V with an Air Volume Totalizer. This microprocessor based unit is designed to eliminate the use of rotometers and mechanical time meters, simplifying air sampling procedures while adding significantly higher accuracy to air sampling data.
The Air Volume Totalizer portion of the sampler is composed of an enclosed air-turbine which rotates at speeds proportional to the air velocity of the sampled air. The turbine’s rotation is sensed by a reflective sensor/breaker disk. The microprocessor converts the signal to volume and displays the flow rate, total volume, and elapsed time on the LCD readout.
The Model H-810 may be operated in the TOTAL VOLUME mode or the TOTAL ELAPSED TIME mode with the mode of operation determined by the user’s established procedures. All functions are entered during the calibration mode. The functions/parameters established during calibration may be locked in using the keypad security. When the keypad security is on, all keys on the keypad are disabled with the exception of the START/STOP and UNITS keys. The UNITS key will toggle the
LCD display from CFM to LPM.
The operation of the Model H-810 is a very simple, four-step procedure, and the training required by the user is relatively short. Its operational procedure is:
1. Connect to a power source. 2. Install the sample holder with filter media.
3. Turn power switch on. 3. Press the start key.
High Volume Air Sampler
MODEL H-810
SPECIFICATIONS
The Model H-810 samples the environment until the desired total volume or total elapsed time has been reached and then turns itself off. The LCD readout indicates the total volume and elapsed sample time. A
STOP key is provided to stop the sampling procedure at any point during the sampling period, and the total volume of air sampled up to that point is indicated. Should the power be cut off, the unit will store the total volume and sample period and display it when power is restored.
If the FLOW reading is blinking during regular operation, it is because the unit is running beyond its calibrated range. This can be corrected by increasing or decreasing flow adjust, located on the left side of the unit.
The Model H-810 has been designed using the latest in technology. The unit is microprocessor based with battery backed data memory to store operational parameters for as long as 10 years. All calibrations are performed using the on-board membrane key pad.
A 2” wide, 6’ belt for carrying purposes or for hanging the instrument during sampling is provided.
A tripod is available as well as different style flow barrels for varying flow rates.
120/220VAC/60Hz; 220/50hz available .
CARTRIDGE
TYPICAL MAXIMUM FLOW RATES
FOR VARIOUS COMBINATIONS OF FILTERS AND CARTRIDGES
HD-2061 FILTER
47mm DIAMETER
LB-5211 FILTER
0750-36
GELMAN AE FILTER
47mm DIAMETER
CP-100
CP-200
BG-300
GY-130
None
FLOW RATE
(CFM)
4.5
8.9
7.4
4.2
11.8
FLOW RATE
(CFM)
3.3
4.9
4.7
3.1
6.0
FLOW RATE
(CFM)
2.8
5.0
3.8
2.7
4.5