Pressalit Height Adjustable Changing Table User Guide
PDF
Document
Advertisement
Advertisement
REF Child Size R8592313 Adult Size R8592318 3 Intended use This product is intended for showering/changing a person who is unable to stand up or sit down. The person is lying horizontally on the shower table. Intended operator profile The product is to be used by a person trained in health care and/or trained in washing/changing a person in their care. Intended user profile The product can be used by all - adults, children, young, old, whose weight does not exceed the maximum load of 200 kg / 440 lbs. Operating environment For indoor use in a wet environment, such as a bathroom or wash room. The product is intended to be used at room temperature, in private homes, nursing homes and hospitals under normal working conditions. Contraindications for use Use of the unit is not recommended for patients with infusion or insulin pump, inflammatory skin diseases or patients in feverish conditions. en Patients with cardiac insufficiency, cardiovascular diseases, craniocerebral injury, open wounds, feed or drain lines (e.g. catheter, drainage tube) may use the unit only after consulting with the attending physician. Biocompatibility The materials in contact with the skin of the user during the intended use have been evaluated for their content of harmful substances according to the procedures in BS EN ISO 10993-1:2020 Biological evaluation of medical devices – Part 1 and are therefore considered suitable for this purpose. ! CAUTION The surface of the product may become hot and / or cold if exposed to external sources of heat or cold (eg sunlight or frost). 12 The product is to be cleaned with hot water or a mild soapy cleaning agent. A list of suitable cleaning agents tested by Pressalit can be found on www.pressalit.com. ! CAUTION Always read the material safety data sheet (MSDS) and supplied instructions of the cleaning, disinfecting or de-scaling agent and comply with instructions for safe use, dilution, rinsing, drying, handling and storage of the agent. IMPORTANT • Do not use an autoclave or other type of steam cleaner. • Avoid aggressive cleaning agents containing acids. • Never spray the product directly with a high pressure cleaner. en • Avoid use of abrasive, corrosive or chlorine-based cleaning or disinfecting products. Disinfection When using the shower table for multiple patients, it is necessary to both clean and disinfect the shower table between uses on different patients to prevent the risk of cross infection. NOTICE If the product is installed in an atmosphere heavy in salt or chloride, the warranty of the shower table will be reduced from the normal 3 years to 1 year. Salt and chloride have a corrosive effect on the products components and will cause a decrease in the life expectancy of the product. The damaging effects can, however, be reduced if the product is showered with tap water on a daily basis. 18 Electromagnetic immunity Electrostatic discharge The product must not be affected by electrical discharge between a person and the product in such a way as to initiate actions or render components defective. Test standard Immunity test level EN 61000-4-2 +/- 8 kV contact +/- 2, 4, 8, 15 kV air Radiated RF electromagnetic field The product must not be affected by radiating RF signals, for example from a mobile phone or radio, that could cause the product to take action or to make components defective. Test standard Immunity test level EN 61000-4-3 15 V/m 80 MHz to 1000 MHz (only on the front) 15 V/m 1,01 GHz to 3 GHz 80 % AM 1 kHz en 25 Disposal and recycling The unit contains reusable materials. There are no known hazards or risks associated with disposal of the product. All components can be discarded after having been cleaned and disinfected. When disposing of the product, we recommend that it be disassembled and broken down into different waste groups for recycling or combustion. The following table provides information on the recycling and handling of the product. Recyclable components Aluminium Steel Material Aluminium is theoretically 100% recyclable without any loss of its natural qualities. It requires only 5% of the energy used to produce primary aluminium. The quality of recycled aluminium is so high that it can be used again and again, even in the case of anodised products as the anodised layer is a natural part of the aluminium. Steel can be recycled by being re-melted and included as a secondary material in the production of new steel. PVC and polystyrene Hard PVC is granulated and re-melted. Use plastic sorting and recycling systems where they are locally available, otherwise incinerating plastic has the added benefit of generating energy, which can be used for, for example, combined heat and power production. Polyurethane Like other plastics, polyurethane can be recycled in two primary ways: mechanical recycling, in which the material is reused in its polymer form, and chemical recycling that takes the material back to its various chemical constituents. Electronics The electronic components should be collected separately and returned to the designated recycling service. en 29 ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement