Shaefer VAF3000A is a portable air ventilator designed to provide high-performance ventilation for various applications. It features a powerful 1 HP motor that delivers up to 2796 CFM (79.2 m³/min) of airflow, making it ideal for ventilating confined spaces, warehouses, workshops, and other industrial settings.
advertisement
AMERIC AXIAL FAN TROUBLESHOOTING
CAUTION: All service procedures should be executed with the unit unplugged.
PROBLEM
Unit will not run.
CAUSE
1) No power to unit.
2) Switch not on.
3) Switch is faulty.
4) Faulty / Broken cord or motor wire.
Unit runs but fan makes loud scraping noise.
Unit runs but fan does not turn.
1) Unit has been severely jolted causing fan to rub against housing.
2) Unit has been severely jolted causing housing to deform.
Unit runs but vibrates excessively.
1) Severe jolt has bent motor shaft causing unit to be out of balance.
2) Fan blade damaged.
3) Dirt build up on one side of fan blade.
1) Fan is jammed against housing.
2) Capacitor wire has broken/come loose, capacitor has failed.
3) Housing has been damaged such that it presses on the fan blade.
SOLUTION
1) Plug unit in. Check circuit breaker.
2) Place in "ON" position.
3) Replace switch.
4) Perform continuity check using volt/amp meter.
Repair/replace faulty/broken wire.
1) Remove motor and replace damaged motor mounts.
2) Replace housing/unit as necessary.
1) Remove and replace motor. Replace fan blade if necessary.
2) Replace fan blade.
3) Clean fan blade.
1) Remove motor and replace damaged motor mounts. Replace fan blade if necessary.
2) Repair/replace wires/capacitor as necessary.
3) Replace housing/unit as necessary.
Unit runs briefly, then shuts off on overload.
1) Motor bearings are failing, or motor has developed an internal electric fault.
2) Intake grill and/or exhaust grill is obstructed.
3) Excessive duct length.
1) Replace motor.
2) Remove obstruction.
3) Reduce duct length to recommended maximum.
(Refer to item # on pictorial breakdown)
Item Part#
1 0SMS8X12PPHSS
3 0CAP40UF240V
0CAP40UF370V
0CC114
4 SWPLTASY-V30A
4 SWPLTASY-V30B
CORD-16/3-20NA
CORD-16/3-20EU
CONNECTOR-PG11
0RSSPST20A
0RSCAP
SWPLT-VAF3000
5 HSG-VAF3000
6 0BM3-0.5X25HHSS
7 0WM3SS
8 0RF78OD
9 0WNM3-0.5HT
10 0RG38X1316X38
11 0RIVET6-8A-B
12 CS211-SP
CS211-50-SP
0NY3816Z
0W38X114FWZ
0S832X14HWHTC
MTRVN-VAF3000
BLADE-VAF3000
13 RING-VAF3000
14 GUARD-VAF3000
Each Description
4 Screw #8 x 1/2" PPH SS
1 Capacitor 115V
1 Capacitor 230V
1 1-1/4" Clamp (230V only)
1 Switch Plate Cord Kit 115V
1 Switch Plate Cord Kit 230V
1 Cord 115V North America
1 Cord 230V European
1 Cord Strain Relief
1 Rocker Switch
1 Rocker Switch Cover
1 Switch Plate
1 Shell Housing Blue
10 Bolt M3x.5 25mm
10 Washer M3 SS
4 Rubber Foot 7/8" OD
10 Well Nut M3x.5
1 Rubber Grommet 3/8"
13 Rivet 3/16" x 1/2" G
1 Motor 1 HP 115V 60 Hz
1 Motor 1 HP 230V 50 Hz
1 Nut Nyloc 3/8" -16
1 Washer 3/8"
12 Screw 8-32 x 1/4" Threading
6 Motor Mount Vane
1 Fan Blade 12" 7 Wing
2 Duct Ring 12"
2 Wire Guard 12"
EUROPEAN CORDS ONLY
WARNING
THIS APPLIANCE MUST BE EARTHED. IMPORTANT!
The wire of this mains lead are colored in accordance with the following code:
BLUE---- NEUTRAL
BROWN---- LIVE
YELLOW / GREEN---- EARTH
As the colors of the wires in the main lead of this appliance may not correspond with the colored markings identifying the terminals in your plug, proceed as follows:
The wire colored brown must be connected to the terminal marked with the letter “L” or colored red.
The wire colored blue must be connected to the terminal marked with the letter “N” or colored black.
The wire colored yellow/green must be connected to the terminal marked with the letter “E” or ensure that your machine is connected correctly. If you are in any doubt consult a qualified electrician.
This appliance must be protected by a 13A fuse if a 13A
(B.S. 1363) plug is used, or if any other type of plug is used by a 5A fuse either in the plug, or adapter or at the distribution board.
©2012 Schaefer Ventilation Equipment. All rights reserved.
M-VAF3000A/B
OWNER’S MANUAL
SAFETY INSTRUCTIONS
Please read and keep these instructions with the fan.
MODEL: VAF3000A/B
For use in Non-Explosive/Non-Flammable environments only.
Purchase Date: ___________________ Serial No. ___________________
Dealer: ______________________________________
1.800.779.3267 • www.schaeferfan.com
Schaefer Limited Warranty Policy
Schaefer Ventilation Equipment, LLC (SVE) provides the following limited warranty from the date of invoice to the initial purchaser of our products or to its customer with a dated proof of purchase:
I. Two-year coverage applies to all products, components and assemblies provided by SVE that prove to be defective in material or workmanship.
Any such defective product will be repaired or replaced at SVE’s option, with the defective product or component returned, upon approval, to SVE, F.O.B Sauk Rapids, Minnesota.
II. This warranty does not cover: a. Failure, damage or malfunction as a result of: i. Improper installation or installation not in accordance with installation instructions.
ii. Operating conditions that vary from SVE’s operating instructions.
iii. Misuse, abuse, negligence, alteration, or accident.
iv. Transporting the product.
v. Improper operation or lack of appropriate or regular maintenance of the product.
b. Loss of time, inconvenience, loss of use of the product or other consequential or incidental damages.
c. Parts that need replacement due to normal wear and tear.
d. Superficial or cosmetic rust or corrosion.
e. Any product whose name plate has been removed.
THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS
OF USE.
Schaefer Ventilation reserves the right to change product design and specification without prior notice or liability.
The above constitutes the sole warranty offered by Schaefer Ventilation
Equipment, LLC.
VAF3000 PICTORIAL BREAKDOWN
MAINTENANCE
DANGER
ALWAYS SHUT OFF THE FAN AND UNPLUG IT FROM ITS POWER SOURCE TO PREVENT ACCIDENTAL STARTING
AND THE POSSIBILITY OF ELECTRICAL SHOCK AND/OR ELECTROCUTION. BE SURE THE FAN BLADE HAS
STOPPED ROTATING BEFORE PLACING ANY OBJECTS OR FINGERS NEAR THE FAN GRILL.
I. Visually check all fasteners and individual components for loose or broken parts. Tighten or replace items as required with only genuine, factory approved replacement parts.
2. Keep the fan blade clean from debris. Accumulation of dust, dirt, paint, etc. on the fan blade will throw the blade rotation out of balance resulting in damage. To clean the fan blade, be sure the plug is disconnected and the blade has stopped rotating. Remove one grill and wipe blade and interior shell housing clean of debris with a damp cloth and mild liquid soap. Dry all parts thoroughly. DO NOT PRESSURE WASH THE FAN. Replace grill prior to next operation.
DANGER
DO NOT OPERATE THE FAN WITHOUT THE INLET AND OUTLET GRILL PROPERLY IN PLACE.
3. Contact Schaefer directly for fan maintenance or repair not described in this manual (or if you are unsure whether maintenance is required.) at Tel# (320) 251-8696 or at www.schaeferfan.com.
SERVICE
1) Refer to the TROUBLESHOOTING GUIDE in this manual.
MOTOR SPECIFICATIONS
A
Voltage 115/100V AC--
Frequency
Phase
60/50 Hz
Single
Electric Motor 1 HP
Current (amps) 8.0/5.7
R.P.M
3300/2800
Watts
Free Air (cfm)
Max S.P.
615W@115V
2796 (79.2m³)
3"
B
220/240V AC--
50Hz
Single
1 HP (.75kw)
4.2
2850
670W @230V
2492 (70.6m³)
2.5" (68mmlaq)
GENERAL INFORMATION & DIMENSIONS
Duct adapter
Height
Width
Length
Weight
Type
12" dia.
21"
14"
17"
32.5 lbs
Axial
(30 cm)
(53.34 cm)
(35.65 cm)
(43.18 cm)
(14.74 kg)
15' duct
25' duct
25' duct
25' duct
40' duct
50' duct
75' duct
AIR FLOW RATES
Feet
(115V AC)
Description CFM M³/Min
Free Air
Straight
Straight
2796
1938
1829
1-90° bend 1564
2-90° bends 1377
Straight 1764
Straight
Straight
1567
1254
79.2
54.9
51.8
44.3
39.0
50.0
44.4
35.5
(230V AC)
CFM M³/Min
2492
1722
1646
1344
1232
1556
1173
1094
70.6
48.8
46.6
38.1
34.9
44.1
33.2
31.0
*Tested in accordance with ANSI/AMCA 230-99 as circulation fans.
The published flow rates are intended to serve only as a reference. Manufacturing tolerances, duct type and specific operating parameters will affect the overall flow rates(s) for each particular fan.
CAUTION
THE AIR FLOW RATE DECREASES AS THE LENGTH OF DUCT INCREASES FOR BOTH BLOWING AND
EXTRACTING APPLICATIONS. AIR FLOW RATES WILL VARY WITH SPECIFIC DUCT TYPES AND
MANUFACTURES.
INTRODUCTION
Congratulations on your selection of a new vane axial fan from Schaefer Ventilation. Our goal is to provide you with the very best in high performance air ventilators. Reading this owner's manual will help you achieve the maximum benefit from your portable air ventilator. If you do not understand any portion of this Manual please contact Schaefer, or your authorized Schaefer dealer for proper assistance prior to operating this Fan.
Do not allow anyone to operate the vane axial fan without first reading the operator's manual and becoming familiar with its operation. Schaefer has endeavored to provide you with the finest equipment available for providing air for portable ventilation purposes. The possibility does exist; however, that the vane axial fan can be subjected to applications not intended by Schaefer.
Misuse and/or misapplication of the vane axial fan can lead to the possibility of serious
damage, injury or even death.
Anyone operating the vane axial fan should refer to current OSHA job safety and health rules and regulations pertaining to the construction industry, with a particular emphasis on 29 CFR 1910, which contains rules governing Permit-Required
Confined Spaces for General Industry.
Record the vane axial fan model and serial number in the space provided below.
Model No.____________________ Serial No. ________________________ Date Purchased ______________________
All specifications are general in nature and are not intended for specific application purposes. Schaefer accepts no responsibility for variations which may be evident in actual products, specifications, pictures and descriptions contained in this publication.
SAFETY PRECAUTIONS
DANGER
THE FAN IS DESIGNED FOR PORTABLE AIR VENTILATION PURPOSES ONLY. THE FAN IS NOT DESIGNED
FOR TRANSPORTING LIQUID OR SEMI-SOLID MATERIALS. THE ELECTRIC MOTOR AND FAN HOUSING ARE
NOT DESIGNED FOR OPERATION IN AN EXPLOSIVE OR FLAMMABLE ATMOSPHERE. OPERATION OF
THE FAN IN AN EXPLOSIVE OR FLAMMABLE ATMOSPHERE MAY RESULT IN PROPERTY DAMAGE,
PERSONAL INJURY OR EVEN DEATH. INCORRECT USE OF THE FAN CAN RESULT IN AN ELECTRICAL
SHOCK AND/OR ELECTROCUTION. ALWAYS OPERATE THE FAN IN COMPLIANCE WITH CURRENT OSHA
AND NATIONAL ELECTRIC CODE REGULATIONS.
DANGER
INCORRECT USE OF THE FAN CAN RESULT IN PROPERTY DAMAGE, PERSONAL INJURY OR EVEN DEATH.
TO REDUCE THIS RISK, GIVE COMPLETE AND UNDIVIDED ATTENTION TO THE JOB AT HAND. AN
ENVIRONMENT ATMOSPHERE CONSTANTLY CHANGES. THEREFORE, IT'S RECOMMENDED THAT AIR
MONITORING/ GAS DETECTION EQUIPMENT BE USED FREQUENTLY. IF TESTS SHOW THAT THE
ATMOSPHERE QUALIFIES AS A HAZARDOUS LOCATION (AN AREA WHERE THE POSSIBILITY OF
EXPLOSION AND FIRE IS CREATED BY THE PRESENCE OF COMBUSTIBLE LIQUIDS, FLAMMABLE GASES,
VAPORS, DUST, FIBERS, FLAMES OR FILINGS.) DO NOT USE THIS FAN. READ AND UNDERSTAND THE
FOLLOWING PREPARATION ITEMS AND GENERAL SAFETY INFORMATION.
PREPARATION
1) Become familiar with the fan operations before utilizing this fan. Read and understand all cautions and warnings in this manual. Refer to current OSHA publications for complete job safety and health rules and regulations (CFR 1926 and 1910).
2) Confirm that the fan is in its original, factory configuration and has not been modified in any manner.
3) Minors should not be allowed to operate the fan. Close attention is necessary when used, especially when used near children or animals.
4) Guard against the possibility of back-related injuries. Always lift the fan with leg muscles and not with the back.
5) Periodically inspect the fan visually for damaged or worn parts. Check for loose and/or broken parts. Be sure that the fan and accessories are in good working condition before operating.
6) Ground the motor securely. The (U.S.) fan utilizes a NEMA 5-15P plug. It is designed to operate ONLY from a grounded, 115 volt nominal AC~, 60Hz, single phase power source that utilizes a NEMA 5-15R receptacle. The 230 volt, 50Hz Fan (VAF3000B) comes with a power cord having no end connector. The customer must provide a plug suitable for use with grounded receptacles at their location. The use of a ground fault circuit interrupter (GFCI) gives additional on the job protection from electrical shock hazards caused by ground faults in commercial, industrial and residential applications.
7) Know how to stop the fan quickly in an emergency. Turn unit off using (on/off) switch located on side of unit or unplug fan from power supply.
GENERAL SAFETY INFORMATION
1) Never place the fan in standing water because of extreme shock hazard.
2) Never allow air intake grill to become blocked.
3) Never discharge flammable solvents or kerosene based chemicals through the fan air intake grill.
4) Do not use the fan in areas where flammable or combustible liquids, gases, vapors, dust, fibers or filings may be present.
5) Never put any object in the air intake grill.
6) Never run the fan outside when it is raining. Never store the Fan outdoors.
7) Do not use the fan as a toy.
8) Use the fan only with a properly grounded outlet.
9) Unplug the fan from outlet when not in use and before servicing.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid state speed control device.
GENERAL SAFETY INFO. (Continued)
10) Do not use the fan with a damaged cord or plug. Do not pull or carry the fan by its cord, do not use cord as a handle, do not close a door on the cord and do not pull cord around sharp edges or corners. Keep cord away from heated surfaces. Do not unplug the fan by pulling on cord. Grasp the plug when unplugging. Do not handle the plug or cord with wet hands.
11) Keep hair, loose clothing, fingers and all parts of the body away from the air intake grill.
12) Do not allow water inside the motor. If the motor becomes wet for any reason, unplug the fan and thoroughly dry it before using again.
13) Never remove the ground from the power cord or plug as this may result in electrical shock or electrocution.
Removing the ground would void the warranty.
14) If the fan has been dropped, left outdoors or dropped into water, etc...,please thoroughly inspect it prior to use.
If the fan is not working or if you have a question about its safe operation, do not operate it. Contact Schaefer
Ventilation directly at (320)251-8696 or at www.schaeferfan.com.
OPERATION
1) Your new fan comes to you completely assembled and ready to operate. Upon removing the fan from its carton, inspect it for any possible damage in transit.
2) Before operating the fan, please read all the safety precautions and general safety information about the proper and safe use of the fan.
3) Assess your job site. Certain job site locations are classified as being hazardous because the atmosphere may contain gas, vapor or dust in explosive quantities.
DANGER
THE ELECTRIC MOTOR AND FAN HOUSING ARE NOT DESIGNED FOR OPERATION IN AN
EXPLOSIVE AND/OR FLAMMABLE ATMOSPHERE OF ANY CLASS OR GROUP. OPERATION
OF THE FAN IN AN EXPLOSIVE OR FLAMMABLE ATMOSPHERE MAY RESULT IN PERSONAL
INJURY OR DEATH.
4) Locate a properly grounded outlet.
5) Prior to plugging the fan into a grounded outlet, inspect the inlet and outlet grills and remove debris which may restrict airflow movement. Never operate the fan without the inlet and outlet grills properly secured and in place. Never replace the grills with other than factory supplied replacement units.
6) Note the directional airflow indicator on the external shell. This is the way the air moves.
7) Place the fan on secure footing to prevent it from shifting while in use.
8) ) Do not stand directly in front of and/or face the fan outlet. Personal injury can result from being struck by debris thrown at a relatively high velocity from the fan blade.
9) When ducting is required, do not install duct while fan is in operation. Place duct lip over the fan duct adapter, secure firmly and note direction of the airflow.
10) When duct is used, be aware that the airflow rate decreases as the length of duct increases. Airflow rates will vary with specific duct types and manufactures.
11 ) Position fan air inlet away from walls and other obstructions to allow for maximum air intake.
12) For safe operation, use the fan only in combination with thorough gas detection tests and continual retesting.
DANGER
ALWAYS ASSUME A CONFINED SPACE WORK AREA IS CONTAMINATED UNTIL IT HAS BEEN
PROVEN SAFE FOR WORK PERSONNEL. NEVER ENTER A CONFINED SPACE WORK AREA
UNTIL IT HAS BEEN THOROUGHLY TESTED WITH APPROPRIATE GAS DETECTION
EQUIPMENT AND PROVEN SAFE FOR WORK PERSONNEL.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- 1 HP motor for powerful airflow
- Axial design for efficient air circulation
- Adjustable airflow direction for targeted ventilation
- Durable construction for long-lasting performance
- Portable design for easy transport and setup
- Safety features to prevent accidents and injuries
Related manuals
Frequently Answers and Questions
What is the maximum airflow rate of the Schaefer VAF3000A?
Can the Schaefer VAF3000A be used in hazardous environments?
What is the voltage and frequency range of the Schaefer VAF3000A?
What is the weight of the Schaefer VAF3000A?
Can the Schaefer VAF3000A be used to transport liquids or semi-solid materials?
advertisement