OutBack Power Technologies FLEXmax 80, 60 Charge Controller Owner’s Manual
PDF
Документ
Реклама
Реклама
FLEXmax Series Charge Controllers (FLEXmax 80, FLEXmax 60) Owner’s Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems. Contact Information Telephone: +1.360.435.6030 (North America) +1.360.618.4363 (Technical Support) +1.360.435.6019 (Fax) Mailing Address: (North America) OutBack Power Technologies 5917 – 195th Street N.E., #7 Arlington, WA 98223 USA E-mail: [email protected] Web Site: www.outbackpower.com Address: Sales, Marketing, & Warranty 6115 – 192nd Street NE Arlington, WA 98223 USA Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES: (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK. Warranty Summary OutBack Power Technologies warrants that the products it manufactures will be free from defects in materials and workmanship for a period of five (5) years subject to the conditions set forth in the warranty detail, found inside the back cover of this manual. OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products. Notice of Copyright FLEXmax Series Charge Controllers Owner’s Manual © February 2012 by OutBack Power Technologies. All Rights Reserved. Trademarks OutBack Power is a registered trademark of OutBack Power Technologies. Date and Revision February 2012, Revision B Part Number 900-0009-01-00 Rev B Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS! This manual contains important safety instructions for the FLEXmax 60 and FLEXmax 80 Charge Controllers. Read all instructions and cautionary markings on the charge controller and on any accessories or additional equipment in the installation. Failure to follow these instructions could result in severe shock or possible electrocution. Use extreme caution at all times to prevent accidents. Audience This manual is intended for use by anyone required to install and operate this equipment. Be sure to review this manual carefully to identify any potential safety risks before proceeding. Installers and operators must be familiar with all the features and functions of this equipment before proceeding. Failure to install or use this equipment as instructed in this manual can result in damage to the equipment that may not be covered under the limited warranty. Symbols Used Symbol Description Ground WARNING: Hazard to Human Life This type of notation indicates that the hazard could be harmful to human life. CAUTION: Hazard to Equipment This type of notation indicates that the hazard may cause damage to the equipment. IMPORTANT: This type of notation indicates that the information provided is important to the installation, operation, and/or maintenance of the equipment. Failure to follow the recommendations in such a notation could result in voiding the equipment warranty. Definitions The following is a list of initials, terms, and definitions used with this product. Table 1 Terms and Definitions Term Definition AC Alternating Current; refers to voltage produced by the inverter, utility grid, or generator AGS Advanced Generator Start AUX Inverter’s 12-volt auxiliary output 900-0009-01-00 Rev B 1 Important Safety Instructions Table 1 Terms and Definitions Term Definition CE Conformité Européenne; French for “European Conformity”; a marking on OutBack products indicating that they meet European Union requirements DC Direct Current; refers to voltage produced by the batteries or renewable source DVM Digital Voltmeter Grid-interactive, grid-tie Utility grid power is available for use and the system is capable of returning (selling) electricity back to the utility grid. LED Light-Emitting Diode; refers to indicators used by the inverter and the system display MPP, MPPT Maximum Power Point, Maximum Power Point Tracking PWM Pulse-Width Modulation PV Photovoltaic RTS Remote Temperature Sensor; accessory that measures battery temperature for charging SK Soft Key; a key with programming that varies with screen System display Remote interface device (such as the MATE, MATE2, or MATE3), used for monitoring, programming and communicating with the inverter; also called “remote system display” Vmp Maximum-power voltage; voltage sought by MPPT where maximum power is harvested Voc Open-circuit voltage; the unloaded voltage displayed by a PV module or array General Safety WARNING: Limitations on Use This equipment is NOT intended for use with life support equipment or other medical equipment or devices. CAUTION: Equipment Damage Only use components or accessories recommended or sold by OutBack Power Technologies or its authorized agents. IMPORTANT: Do not attempt to install this equipment if it appears to be damaged in any way. See the Warranty section for instructions on returning the equipment. Personal Safety WARNING: Personal Injury 2 Use standard safety equipment such as safety glasses, ear protection, steel-toed safety boots, safety hard hats, etc. as prescribed by the Occupational Safety and Health Association (or other local codes) when working on this equipment. Use standard safety practices when working with electrical equipment (Remove all jewelry, use insulated tools, wear cotton clothing, etc.) Never work alone when installing or servicing this equipment. Have someone nearby in case emergency assistance is required. 900-0009-01-00 Rev B Important Safety Instructions Product Safety WARNING: Lethal Voltage Review the system configuration to identify all sources of energy. Disconnect ALL sources of power before performing any installation or maintenance on this equipment. Confirm that the terminals are de-energized using a validated voltmeter (rated for a minimum 1000 Vdc) to verify the de-energized condition. Do not perform any servicing other than that specified in the installation instructions unless qualified to do so and have been instructed to do so by OutBack Power Technologies Technical Support personnel. WARNING: Burn Hazard Internal parts can become hot during operation. Do not remove the cover during operation or touch any internal parts. Be sure to allow them sufficient time to cool down before attempting to performance any maintenance. WARNING: Fire Hazard Do not place combustible or flammable materials within 3.7 m (12 feet) of the equipment. Use only the recommended cable sizes for DC conductors in compliance with local codes. Ensure all conductors are in good condition. Do not operate the unit with damaged or substandard cabling. CAUTION: Equipment Damage Thoroughly inspect the equipment prior to energizing. Verify that no tools or equipment have been inadvertently left behind. Ensure clearance requirements are strictly enforced. Keep all vents clear of obstructions that can prevent air flow around, or through, the unit. Sensitive electronics inside the equipment can be destroyed by static electricity. Be sure to discharge any static electricity built up before touching the equipment and wear appropriate protective gear. PV Safety WARNING: Shock Hazard Photovoltaic (PV) arrays can be energized with minimal ambient light available. Therefore to ensure a safe disconnect from the system, be sure to install a PV disconnect, breaker, or accessible fuse box (depending on local code requirements). CAUTION: Equipment Damage PV Arrays must be wired with correct polarity (positive-to-positive, negative-tonegative). Connecting the cables incorrectly can damage or destroy the equipment. 900-0009-01-00 Rev B 3 Additional Resources Battery Safety WARNING: Explosion, Electrocution, or Fire Hazard Use the battery types recommended by OutBack Power Technologies. Follow the battery manufacturer’s recommendations for installation and maintenance. Ensure the cables are properly sized. Failure to size the cables properly can results in a fire hazard. Ensure clearance requirements are strictly enforced around batteries. Ensure the area around the batteries is well ventilated and clean of debris. Never smoke or allow a spark or flame near the batteries. Always use insulated tools. Avoid dropping tools onto batteries or other electrical parts. Keep plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. Wear complete eye protection and clothing protection when working with batteries. Avoid touching bare skin or eyes while working near batteries. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters the eye, immediately flood it with running cold water for at least 20 minutes and get medical attention immediately. Never charge a frozen battery. If a battery needs to be removed, always remove the ground terminal from the battery first. Make sure all accessories are turned off to avoid creating sparks. IMPORTANT: Baking Soda neutralizes lead-acid battery electrolyte. Vinegar neutralizes NiCad and NiFe battery electrolyte. Have a supply of either substance readily available if using these types of batteries. Regulatory Specifications See page 99 for all specifications and regulatory information. Required Resources This product is required to be installed according to pertinent safety codes and standards. If installed in the United States, wiring practices must meet the requirements of the National Electrical Code (NEC). If installed in Canada, wiring practices must meet the requirements of the Canadian Electrical Code. National Electrical Code (NEC)/NFPA 70, Current Edition Canadian Electrical Code, C22.1, Current Edition Additional Resources The following are references which may be used when installing this equipment. Depending on the nature of the installation, it may be highly recommended to consult any or all of these resources. 4 National Electrical Code (NEC) or NFPA 70 Handbook, Current Edition UL 1741, Current Edition, Static Inverter and Charge Controllers for Use in Photovoltaic Power Systems International Building Code (IBC), Current Edition Photovoltaic Power Systems and the 2005 National Electrical Code: Suggested Practices 900-0009-01-00 Rev B Additional Resources Recycling Information IMPORTANT: Recycle Electronics and Batteries Batteries are considered hazardous waste and must be recycled according to local jurisdiction. Inverters and other electronics contain metals and plastics that should also be recycled. The following websites and phone numbers provide additional information for recycling electronic products and batteries. Earth 911, USA Web site: Address: Phone: http://www.Earth911.com 14646 N. Kierland Blvd., Suite 100 Scottsdale, AZ 85254 +1.480.337.3025 (direct) Environmental Protection Agency, USA Web site: Address: http://www.epa.gov/wastes/conserve/materials/ecycling/donate.htm EPA USA Office of Resource Conservation and Recovery (5305P) 1200 Pennsylvania Avenue NW Washington, DC 20460 Keep America Beautiful, USA Web site: Email: Address: Phone: Fax: www.kab.org/ [email protected] 1010 Washington Boulevard Stamford, CT 06901 +1.203.659.3000 (Main number) +1.203.659.3001 OurEarth.org, USA There is a place on the Web site for contacting OurEarth.org using email. No direct email address is provided. Web site: Address: Phone: http://www.ourearth.org P.O. Box 62133 Durham, NC 27715 +1.410.878.6485 Natural Resources Canada Address: Phone: TTY: Web site: 900-0009-01-00 Rev B 580 Booth, Ottawa, ON K1A 0E8 +1.613.995.0947 +1.613.996.4397 (Phone 7and TTY: Monday to Friday, 8:30 a.m. to 4:30 p.m. ET) http://www.nrcan-rncan.gc.ca/mms-smm/busi-indu/rec-rec-eng.htm 5 Additional Resources Office of Waste Management, Canada Address: Phone: Web site: Office of Waste Management Conservation and Protection Environment Canada Ottawa, Ontario K1A 0H3 +1. 819.997.2800 http://www.portaec.net/library/recycling/recycling_in_canada.html National Institute of Recyclers, Mexico Web site: Email: Phone: Fax: http://www.inare.org.mx/ [email protected], [email protected] 55.57.85.9160 55.57.84.1279 EuroRecycle.net The following Web site provides general information about recycling in Europe. It also provides a list of companies and organizations that provide recycling information or assistance. Web site: E-mail: 6 http://euro.recycle.net/assn/index.html http://euro.recycle.net/cgi-bin/feedback1.cgi?w=27 (This is an online form providing a means to contact the owners of the web site.) 900-0009-01-00 Rev B Table of Contents Important Safety Instructions ............................................................................................................................... 1 Audience................................................................................................................................................................................................... 1 Symbols Used ......................................................................................................................................................................................... 1 Definitions................................................................................................................................................................................................ 1 General Safety......................................................................................................................................................................................... 2 Personal Safety ....................................................................................................................................................................................... 2 Product Safety ........................................................................................................................................................................................ 3 PV Safety................................................................................................................................................................................................... 3 Battery Safety.......................................................................................................................................................................................... 4 Regulatory Specifications ................................................................................................................................................................... 4 Required Resources .............................................................................................................................................................................. 4 Additional Resources............................................................................................................................................................................ 4 Recycling Information.......................................................................................................................................................................... 5 Introduction...............................................................................................................................................................11 Features ..................................................................................................................................................................................................11 Firmware.................................................................................................................................................................................................11 Soft Keys .................................................................................................................................................................................................12 Installation..................................................................................................................................................................13 Standards and Requirements ..........................................................................................................................................................13 Grounding ........................................................................................................................................................................................13 DC and Battery-Related Installation Requirements............................................................................................................13 Dimensions............................................................................................................................................................................................14 Mounting the Charge Controller....................................................................................................................................................15 Wiring ......................................................................................................................................................................................................16 Wire and Disconnect Sizing........................................................................................................................................................16 FLEXmax 80 ................................................................................................................................................................................16 FLEXmax 60 ................................................................................................................................................................................16 Wiring Compartment....................................................................................................................................................................17 Operation....................................................................................................................................................................21 Power Up Screens................................................................................................................................................................................21 Version and/or Voltage Setting Screens.................................................................................................................................22 Status Screen ...................................................................................................................................................................................23 End-of-Day Summary Screen .....................................................................................................................................................24 Navigating the End-of-Day Screens and Data Logging ....................................................................................................25 Modes of Operation............................................................................................................................................................................26 Absorbing.........................................................................................................................................................................................26 Auto Start (Auto ReStart).............................................................................................................................................................27 BatTmpErr.........................................................................................................................................................................................27 BatTooHot ........................................................................................................................................................................................27 Charged.............................................................................................................................................................................................27 EQ ........................................................................................................................................................................................................27 EQ Done ............................................................................................................................................................................................27 EX-Absorb.........................................................................................................................................................................................28 Floating .............................................................................................................................................................................................28 GT Mode............................................................................................................................................................................................28 High Voc............................................................................................................................................................................................28 Low Light or Snoozing .................................................................................................................................................................28 MPPT Bulk.........................................................................................................................................................................................28 900-0009-01-00 Rev B 7 Table of Contents MPPT Float........................................................................................................................................................................................28 MPPT EQ............................................................................................................................................................................................29 New Voc ............................................................................................................................................................................................29 OvrCurrent........................................................................................................................................................................................29 Over Temp........................................................................................................................................................................................29 Re-Cal .................................................................................................................................................................................................29 Sleeping ............................................................................................................................................................................................29 Sys Error.............................................................................................................................................................................................29 Tracking.............................................................................................................................................................................................29 Unloaded ..........................................................................................................................................................................................30 Wakeup..............................................................................................................................................................................................30 Zzzzz... ................................................................................................................................................................................................30 Initial Operation ...................................................................................................................................................................................30 Changing the Settings on the FLEXmax ......................................................................................................................................30 Accessing the Main Menu ...........................................................................................................................................................30 Main Menu Map..............................................................................................................................................................................31 Charger Screen..........................................................................................................................................................................32 Aux Screens................................................................................................................................................................................33 AUX MODE Screen Navigation.............................................................................................................................................35 Vent Fan (AUX Mode)........................................................................................................................................................36 PV Trigger (AUX Mode).....................................................................................................................................................37 Error Output (AUX Mode) ................................................................................................................................................38 Night Light (AUX Mode) ...................................................................................................................................................39 Float (AUX Mode) ...............................................................................................................................................................40 Diversion (AUX Mode).......................................................................................................................................................41 Low Battery Disconnect (AUX Mode)...........................................................................................................................46 Remote (AUX Mode)..........................................................................................................................................................47 Backlight......................................................................................................................................................................................47 EQ – Battery Equalize ..............................................................................................................................................................48 Misc Screen.................................................................................................................................................................................50 Advanced Menu........................................................................................................................................................................52 Snooze Mode (Advanced Menu)...................................................................................................................................52 Wakeup Mode (Advanced Menu) ................................................................................................................................53 MPPT Mode (Advanced Menu) ......................................................................................................................................53 Absorb Time Limits (Advanced Menu)........................................................................................................................55 Absorb End Amps (Advanced Menu)...........................................................................................................................55 Rebulk Voltage (Advanced Menu) ................................................................................................................................56 Vbatt Calibration (Advanced Menu).............................................................................................................................56 RTS Compensation (Advanced Menu).........................................................................................................................56 Auto ReStart (Advanced Menu) .....................................................................................................................................58 Aux Polarity (Advanced Menu) ......................................................................................................................................59 Reset to Defaults? ...............................................................................................................................................................59 Logging .......................................................................................................................................................................................60 Stats ..............................................................................................................................................................................................61 Viewing the Firmware Revision.................................................................................................................................................62 Extended Play Mode .....................................................................................................................................................................62 Rebooting the FLEXmax ..............................................................................................................................................................63 MATE3 System Display and Controller............................................................................................................65 Display and LED Status Indicators..................................................................................................................................................65 Charge Controller Soft Key....................................................................................................................................................66 DataLog Screen ...................................................................................................................................................................67 Graph Screens......................................................................................................................................................................68 Menu Structure in the MATE3 .........................................................................................................................................................69 Charge Controller Settings...............................................................................................................................................................70 Charger..............................................................................................................................................................................................70 MPPT...................................................................................................................................................................................................70 8 900-0009-01-00 Rev B Table of Contents Temperature Compensation......................................................................................................................................................71 Battery Equalize..............................................................................................................................................................................71 Grid-Tie Mode..................................................................................................................................................................................71 Auxiliary Output (Charge Controller) ......................................................................................................................................72 Aux Modes for the Charge Controller ...............................................................................................................................72 Restart Mode..............................................................................................................................................................................73 Calibrate ......................................................................................................................................................................................74 Reset Charge Controller to Factory Defaults...................................................................................................................74 Device Data Logs .................................................................................................................................................................................75 Saving Data Logs for the FLEXmax Charge Controller ......................................................................................................75 Data Log File Format .........................................................................................................................................................76 MATE/MATE2 Screens............................................................................................................................................77 Summary Screens ................................................................................................................................................................................77 Status Screens.......................................................................................................................................................................................78 MODE Screens.................................................................................................................................................................................78 METER Screens ................................................................................................................................................................................79 SETPT Screens .................................................................................................................................................................................80 LOG Screens.....................................................................................................................................................................................81 STAT Screens ...................................................................................................................................................................................82 Advanced Menus.................................................................................................................................................................................83 Accessing the Advanced Menus ...............................................................................................................................................83 CHGR Menu......................................................................................................................................................................................84 CC ADVANCED Menu....................................................................................................................................................................85 EQ Menu............................................................................................................................................................................................86 AUX Menu.........................................................................................................................................................................................87 MATE and MATE2 Menu Maps for the FLEXmax.......................................................................................................................88 STATUS Menu Map ........................................................................................................................................................................88 Advanced Menu Map ...................................................................................................................................................................90 Menu Maps for the FLEXmax ..............................................................................................................................93 Troubleshooting ......................................................................................................................................................97 Specifications ............................................................................................................................................................99 Electrical and Mechanical Specifications.....................................................................................................................................99 Firmware Revision ...............................................................................................................................................................................99 Regulatory Specifications .................................................................................................................................................................99 Default Settings and Ranges......................................................................................................................................................... 100 Applications............................................................................................................................................................ 101 Maximum Power Point Tracking ................................................................................................................................................. 101 Three-Stage Battery Charging...................................................................................................................................................... 102 BULK ................................................................................................................................................................................................ 102 ABSORBING ................................................................................................................................................................................... 103 FLOAT.............................................................................................................................................................................................. 103 Battery Temperature Compensation.................................................................................................................................... 103 Array Design....................................................................................................................................................................................... 104 Sizing Guidelines......................................................................................................................................................................... 104 Open Circuit Voltage (Voc) ................................................................................................................................................... 104 Weather Conditions.............................................................................................................................................................. 104 Maximum-Power Voltage (Vmp) ........................................................................................................................................... 105 Standard vs. Australian Default Settings .................................................................................................................................. 105 Hydroelectric and Fuel Cell Applications Performance Optimization............................................................................ 106 Auto Track Mode......................................................................................................................................................................... 106 U-Pick Mode.................................................................................................................................................................................. 106 Grid-Interactive Settings ................................................................................................................................................................ 108 Charge Controller Efficiency vs. Input Power.......................................................................................................................... 108 900-0009-01-00 Rev B 9 Table of Contents Product Registration............................................................................................................................................ 109 Extended Warranty .......................................................................................................................................................................... 110 Warranty................................................................................................................................................................... 111 How to Arrange for Warranty Service........................................................................................................................................ 112 Contacting OutBack ................................................................................................................................................................... 112 Troubleshooting.......................................................................................................................................................................... 112 Return Material Authorization (RMA)................................................................................................................................... 112 Returning Product to OutBack ............................................................................................................................................... 113 Out of Warranty ..................................................................................................................................................................... 113 Index.......................................................................................................................................................................... 115 List of Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 10 Terms and Definitions ...................................................................................................................................................... 1 Battery Voltage and Charge Timer.............................................................................................................................27 Aux Mode Functions.......................................................................................................................................................33 Regulatory Specifications for All Models .................................................................................................................99 FLEXmax Settings ......................................................................................................................................................... 100 Maximum PV Input Wattage per Charge Controller......................................................................................... 104 Default Settings Standard vs. Australian .............................................................................................................. 105 900-0009-01-00 Rev B Introduction IMPORTANT: This manual provides safety guidelines and installation information for the FLEXmax Series Charge Controllers. It does not provide information about specific brands of PV modules and supplies limited information on batteries. Contact the supplier or manufacturer of the PV modules or batteries for additional information. Thank you for purchasing a FLEXmax Series Charge Controller (CC). These charge controllers offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a PV array. Each charge controller is designed to seamlessly integrate with other OutBack components and can be remotely monitored and configured (up to 1000 feet or 300 meters away) using the optional OutBack Power Technologies system displays. Features The FLEXmax Charge Controllers use continuous Maximum Power Point Tracking (MPPT), which seeks out the maximum power available from a PV array and uses it to recharge the batteries. Without this feature, the PV array does not operate at the ideal voltage and can only operate at the level of the battery voltage itself. (See page 101 for a description of MPPT.) Each charge controller continuously tracks the array’s maximum operating power. The FLEXmax Series has two models available: FLEXmax 80: 80 amps maximum continuous output current (up to 40°C without thermal derating) FLEXmax 60: 60 amps maximum continuous output current (up to 40°C without thermal derating) Both models have the following features: Supports 12, 24, 36, 48, and 60 Vdc battery voltages Backlit LCD display screen with 80 characters (4 lines, 20 characters per line) Last 128 days of operational data are logged for review Voltage step-down capability allowing a higher PV array voltage configuration Manual and auto-equalize cycle Firmware This manual covers FLEXmax firmware revision 002.001.xxx. 900-0009-01-00 Rev B 11 Introduction LCD Screen Soft Keys FLEXmax 80 Figure 1 FLEXmax 60 Charge Controller Features Soft Keys Four “soft” keys are located directly below the LCD. The functions of the soft keys will vary depending on the location of the user within the menu structure. Some soft keys will be used for navigation. Some soft keys will be used for programming. Soft key functions are identified by text in the LCD screen directly above the key (e.g., EXIT). In this manual, soft keys will be identified by brackets (for example, <EXIT>). Not every soft key may be used in some screens. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Soft Key Buttons LCD Soft Key Commands <EXIT>, <GO> etc. SK1 SK2 SK3 SK4 Figure 2 12 Soft Keys 900-0009-01-00 Rev B Installation Standards and Requirements All installations must comply with national and local electrical codes; professional installation is recommended. IMPORTANT: The charge controller is designed for indoor installation or installation inside a weatherproof enclosure. It must not be exposed to rain and should be installed out of direct sunlight. Grounding This product is intended to be installed as part of a permanently grounded electrical system as shown in the wiring diagrams shown in Figure 6, Figure 7, and Figure 8. The FLEXmax equipment ground is marked with this symbol: The following important restrictions apply unless superseded by local or national codes: The negative battery conductor should be bonded to the grounding system at only one point in the system. If a GFDI is present, the battery negative and ground are not bonded together directly but are connected together by the GFDI device when it is on. All negative conductor connections must be kept separate from the grounding conductor connections. The FLEXmax controller is not intended to be wired into a positive-ground configuration. However, certain telecom applications may require this configuration. If it is necessary to build a positive-ground system with OutBack products, contact OutBack Technical Support at +1.360.618.4363 before proceeding. Additionally, consult the online forum at www.outbackpower.com/forum/, where this subject has been discussed extensively. If damaged or malfunctioning, the FLEXmax should only be disassembled and repaired by a qualified service center. Please contact the local renewable energy dealer/installer for assistance. Incorrect reassembly risks malfunction, electric shock or fire. DC and Battery-Related Installation Requirements Shut off all DC circuit breakers before connecting any wiring. Torque all the FLEXmax wire lugs and ground terminals to 4 Nm (35 in-lb). Copper wiring must be rated at 75°C or higher. Use up to 35 mm2 (2 AWG) to reduce losses and ensure highest performance of the FLEXmax (smaller cables can reduce performance and possibly damage the unit). Run positive and negative cables side by side. ~ Keep cables together (e.g., using a tie-wrap) as much as possible to allow the inductive currents to cancel. ~ Ensure paired cables pass through the same knockout and conduit fittings. DC battery overcurrent protection must be used as part of the installation. OutBack offers both circuit breakers and fuses for overcurrent protection. 900-0009-01-00 Rev B 13 Installation Dimensions 16.25” (41.3 cm) FLEXmax 80 Charge Controller 5.75” (14.6 cm) FLEXmax 60 Charge Controller Figure 3 14 4.0” (10.2 cm) 13.5” (34.3 cm) FLEXmax 80 and FLEXmax 60 Dimensions 900-0009-01-00 Rev B Installation Mounting the Charge Controller IMPORTANT: Install the FLEXmax in an upright position out of direct sunlight. The FLEXmax is designed to attach directly to OutBack’s FLEXware 500 DC and FLEXware 1000 DC enclosures (FLEXware 500 shown) or attach to its own charge controller brackets (FW-CCB, FW-CCB2, and FW-CCB2T). Mounting directly to a FLEXware DC enclosure: 1. Remove the fan cover and bottom cover from the FLEXmax. 2. Insert a #10 X 3/8” sheet metal screw in the top hole on the side of the DC enclosure. This will act as a hanging screw for the keyhole slot at the top center of the FLEXmax. Holes for #10 x 3/8” sheet metal screws Insert screws through lower holes inside the charge controller. 3. Hang the FLEXmax on the top screw and line up its bottom two screw holes with the holes on the enclosure. 4. Insert a #10 x 3/8” sheet metal screw through each hole and tighten against the enclosure (screws are included with each DC enclosure). 5. Keep the cover off until wiring is completed. The conduit nipple assembly creates a sealed connection from the FLEXmax to the enclosure. DC Enclosure Charge Controller (front view) Mounting to Plywood Use 1-5/8” wood screws to secure the FLEXmax at the top slotted holes and other interior lower holes as needed, making sure the unit is straight and level. Bushing Lock Nut Lock Nut Figure 4 900-0009-01-00 Rev B Conduit Nipple Mounting the Charge Controller 15 Installation Wiring This section provides instructions on installing PV array wiring into the FLEXmax controller. See page 104 for more notes on PV array sizing and operation. Wire and Disconnect Sizing IMPORTANT: Wire sizes must comply with local and national codes. See page 4. Input conductors and circuit breakers must be rated at 1.56 times the short-circuit current of the PV array (per NEC). OutBack 100% duty continuous circuit breakers only need to be rated at 1.25 times the short-circuit current. Copper wiring must be rated at 75°C or higher. Use up to 2 AWG (33.6 mm2) to reduce losses and ensure high performance of the FLEXmax (smaller cables can reduce performance and possibly damage the unit). FLEXmax 80 The output current limit of the FLEXmax 80 is 80 amps. Install OutBack PNL-80-DC circuit breakers for disconnect and overcurrent protection Use a minimum of #4 AWG (25 mm2) wire for the output between the FLEXmax 80 and the battery bus bar conductors. The largest PV array must have a rated short-circuit current of 64 amps or less under STC (Standard Test Conditions). Torque all the FLEXmax wire lugs and ground terminals to 4 Nm (35 in-lb). FLEXmax 60 The output current limit of the FLEXmax 60 is 60 amps. Install OutBack PNL-60-AC/DC or PNL-80-DC circuit breakers for disconnect and overcurrent protection. Use a minimum of #6 AWG (16 mm2) wire for the output between the FLEXmax 60 and the battery bus bar conductors. The largest PV array must have a rated short-circuit current of 48 amps or less under STC (Standard Test Conditions). Torque all the FLEXmax wire lugs and ground terminals to 4 Nm (35 in-lb). Please refer to the NEC and other electrical codes for recommendations on PV array cable sizing and recommended length and ampacity. 16 900-0009-01-00 Rev B Installation Wiring Compartment WARNING: Shock Hazard Make sure all DC circuit breakers are OFF (open) BEFORE making any wiring connections. Use a DVM to check for voltage on all wires. The PV (-) and BAT (-) terminals are connected internally. Only one negative wire may be needed to connect to the (-) wire lugs if the PV - and BAT- conductors are bonded at the negative bus bar. See Figure 6, Figure 7, and Figure 8 for sample wiring diagrams. Auxiliary output terminals Wire terminals Battery Remote Temp Sensor (RTS) RJ11 port PV+ PV– BAT– BAT+ MATE/HUB RJ45 port Use up to 35 mm2 (2 AWG) wire Torque to 4 Nm (35 in-lb) Chassis/Equipment Ground Lug Screw holes for mounting the charge controller Figure 5 Wiring Compartment CAUTION: Equipment Damage Each FLEXmax requires its own PV array. DO NOT PARALLEL FLEXmax PV+ and PVTERMINALS ON THE SAME ARRAY! An optional battery Remote Temperature Sensor (RTS) is recommended for accurate battery charging. Only one RTS is needed for multiple OutBack inverter/chargers and charge controller units when the system includes an OutBack HUB and a system display. When one RTS is used, it must be connected to the component plugged into the Port 1 of the HUB. 900-0009-01-00 Rev B 17 Installation Figure 6 18 Wiring Diagram - Single Charge Controller with PV Array 900-0009-01-00 Rev B Installation Figure 7 900-0009-01-00 Rev B Wiring Diagram – Charge Controller with PV Array and Inverter 19 Installation Figure 8 20 Wiring Diagram – Charge Controller with PV Array Ground Fault Protection 900-0009-01-00 Rev B Operation Operation of this unit consists of monitoring screens and programming screens. The majority of programming screens are accessed using the main menu. See page 30. Power Up Screens IMPORTANT: The default settings of the FLEXmax are for a 12 Vdc battery bank. Change the setting after powering up if a different battery voltage is used. Once set, the FLEXmax retains the nominal voltage setting. Following any type of shutdown or disconnect, it will return to operation automatically. The PV array voltage is automatically detected. The PV array voltage must never exceed 150 Voc. It is recommended to restore the FLEXmax to factory default settings (see page 59) and reset the nominal voltage any time the system is substantially revised or the controller is relocated. The FLEXmax uses power from the battery bank to operate. The battery voltage must be at least 10.5 volts or higher to power up the FLEXmax. When battery power is detected, the FLEXmax will go through a series of power-up screens. Power Up Screen OutBack System Voltage 12V Power Systems Charge Controller - AU On Australian versions only To power up the charge controller: 1. Ensure the PV array and battery circuit breakers are OFF. 2. Turn ON the battery circuit breaker only. The FLEXmax will show the system battery voltage in the upper right corner of the screen. If the screen reads Low Battery Voltage, please see the Troubleshooting section on page 97. If the Australian version was previously selected, AU will be displayed in the lower right corner of the screen. To change version settings: OutBack 12V While turning on the circuit breaker, press and hold the first and third soft keys. This brings up the Select Version screen. Changing the version settings requires entering a password. Systems Charge Controller - AU Power NOTE: This process will reset the FLEXmax to its default settings. It may be necessary to re-enter previous settings. To change the system password: 1. Press <NEXT> or <SEL> when the Select Version screen appears on power up. This will open the PASSWORD screen. 2. Press <–> or <+> to reduce the number from 150 to 141. 3. Press <ENTRA> or <ENTER> to enter the new password. Figure 9 PASSWORD CONTRASENA ***150*** ENTRA + ENTER PASSWORD Screen Continued on next page... Powering up the FLEXmax Select Version offers two types of options. The English (default) or Spanish selections offer standardized charge settings in two languages. Selecting Australian leaves the menus in English, but changes the charging parameters. (For details, see Table 7 on page 105.) 900-0009-01-00 Rev B 21 Operation Version and/or Voltage Setting Screens Once the password has been entered, the display will return to the Select Version screen. Select Version Screen To change the version: Select Version Elija la Version English NEXT ENTER ENTRA SEL 1. or Select Version Screen Select Version Elija la Version English NEXT ENTER ENTRA SEL Press <NEXT> or <SEL> to cycle through the version choices of: English, Australian, or Espanola. 2. When the desired version is displayed, press <ENTER> or <ENTRA> to proceed to the confirmation screen. 3. Press <YES> to confirm the selection. or Confirmation Screen Are you sure? English NO YES SYSTEM VOLTAGE Screen SYSTEM VOLTAGE 24 36 48 60 12 ^^ The SYSTEM VOLTAGE screen appears next. ENTER The FLEXmax automatically detects the system’s battery voltage and indicates it by placing two ^^ symbols below the value. Verification Screen 12 ^^ NO Are you sure? 24 36 48 60 If the value indicated is correct, press <ENTER>. If the value indicate is not correct for the present system, press <> to move the ^^ to below the correct voltage. Press <YES> to confirm the selection. YES Status Screen In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Figure 10 22 The Status screen is the last screen to be displayed after startup. The soft keys below the Status screen navigate to the main menu and the End-of-Day summary screen. See page 23 for details on the Status screen. Changing the Version Setting 900-0009-01-00 Rev B Operation Status Screen The status screen displays system information. See page 24 for detailed information of the different modes of operation. The optional OutBack system display shows CC (Charge Controller) status screens for convenient distant viewing from the installation location. See page 65 for the FLEXmax screens displayed on the MATE3. Please see pages 77 to 89 to view the FLEXmax screens displayed on the MATE (or MATE2). Status Screen In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping PV Input Voltage In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping PV Input Current In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Battery Voltage In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Daily Accumulated Kilowatt-hours In Out 0.0 A 0.0 A 0.0 kWH Sleeping AUX Status (ON or OFF) The PV voltage will slowly rise to the battery voltage level even when the PV breaker is off – this is normal as the PV capacitors charge up. Navigation Status Screen 11.6V 13.8V 0.000 kW AUX: OFF Output Current Instantaneous Kilowatts In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Pressing the first soft key (SK1) opens the main menu screen. Status Screen In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Pressing SK2 opens the end-of-day summary menu and logging. In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Mode of Operation See page 26 Figure 11 900-0009-01-00 Rev B Status Screen 23 Operation End-of-Day Summary Screen The end-of-day summary screen appears after one hour of continuous Sleeping (see page 29). This screen can be opened any time by pressing the second soft key while in the status screen, providing a summary up to that point. End-of-Day Screen NOTE: When finished viewing the end-of-day screen(s), be sure to return the display to the status screen. Otherwise, it will not reset the counters when the sun rises the next morning. The values will continue to accumulate. Figure 12 24 Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Day (up to 128 days) Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Accumulated Amp-hours Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Accumulated kWh Total Power Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Peak Input Voltage Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Peak Output Current Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Peak Output Power in Kilowatts Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Maximum Battery Voltage Obtained Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Accumulated Absorb Time Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Minimum Battery Voltage Obtained Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Accumulated Float Time End-of-Day Summary Screen 900-0009-01-00 Rev B Operation Navigating the End-of-Day Screens and Data Logging Status Screen In Out 11.6V 13.8V 0.000 kW AUX: OFF End-of-Day Screen 0.0 A 0.0 A 0.0 kWH Sleeping Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Press SK1 to return to the status screen. Pressing the second soft key (SK2) opens the end-of-day summary menu/logging. CLEAR LOG Screen The daily statistics or the accumulated statistics are stored on the charge controller's static memory. A new log “day” begins when the controller enters Wakeup. (See page 30.) Logs accumulate for up to 128 days. See pages 81 and page 82 for details. End-of-Day Screen Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 CLEAR LOG Press SK2 to open the CLEAR LOG screen. BACK TOTL DAILY OR End-of-Day Screen Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Are you sure? NO YES OR Press SK3 to open the previous day’s summary screen. Continuing to press this soft key will cycle back through the last 128 daily summary screens. End-of-Day Screen Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Pressing SK4 will bring up the summary for the 128th day back. Figure 13 900-0009-01-00 Rev B End-of-Day Screen Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 Press SK1 to return to the status screen. This data log can be downloaded to an SD card. The MATE3 system display is required for this download. See page 75 for details on this feature. Navigating the End-of-Day Summary Screen 25 Operation Modes of Operation The FLEXmax has 25 different modes that will display on the status screen. These messages will vary with function. The FLEXmax modes consist of various charging stages, equalization, various reasons for stopping charging, and certain specialized operating modes. The amount of time required before starting operation is dependent on the module type, ambient temperature, and the amount of sunlight directly on the PV array. Normally, the FLEXmax starts in the morning within a few minutes of the PV array being exposed to direct sunlight. The FLEXmax modes of operation will change occasionally during the day based on the PV array output and the battery system state of charge. The FLEXmax operating modes are displayed at the bottom right hand corner of the status screen. See Figure 11. Figure 14 shows an example of the various stages of operation during battery charging and the messages shown during each stage. Battery charging is described in detail on page 102. Figure 14 FLEXmax Battery Charging and Modes Absorbing The FLEXmax is in the Absorbing stage of a three-stage cycle, regulating the battery voltage at the Absorbing voltage set point. While the batteries are held at this voltage, the ChgT counter in the Misc menu counts up from zero toward the user-defined Absorb Time Limit. (See pages 50 and 55.) The charger will exit this stage and enter the Float stage if the ChgT timer reaches the time limit, or if the Absorb End Amps setting is reached. (See page 55.) If the battery voltage drops below the Absorbing voltage (see page 32), the FLEXmax reverts back to the Bulk charge stage and displays MPPT Bulk as shown on page 28. The ChgT counter will begin counting back toward zero. Lower voltages will cause the timer to subtract minutes at a faster rate, as shown on Table 2 on page 27. 26 900-0009-01-00 Rev B Operation Table 2 Battery Voltage and Charge Timer Battery Voltage ChgT (Charge Timer) Activity/Display 12.4 V, 24.8 V, 37.2 V, 49.6 V, or 62.0 V, and less than the Absorbing voltage No change. <12.4 V, 24.8 V, 37.2 V, 49.6 V, or 62.0 V For every minute elapsed, 1 minute is subtracted from the timer <12.0 V, 24.0 V, 36.0 V, 48.0 V, or 60.0 V For every minute elapsed, 2 minutes is subtracted from the timer < 11.6 V, 23.2 V, 34.8 V, 46.6 V, or 58.0 V For every minute elapsed, 4 minutes is subtracted from the timer. Auto Start (Auto ReStart) This setting allows the user to choose between continuous MPP tracking or occasional restarts of the sweeping process. A restart means the controller abandons the existing maximum power point and “re-sweeps”, or begins gathering new power point data. See page 58 for more information. Mode 1: Once every 1.5 hours in the Bulk charging stage Mode 2: Once every 1.5 hours in the Bulk, Absorbing and Float recharging stages Mode 0: Auto ReStart is disabled completely. It will continously track the maximum power point without starting over. NOTE: If enabled, AutoStart also occurs during the MPPT EQ cycle. See page 29. BatTmpErr The battery temperature sensor is shorted or damaged. The charging voltage will not be temperature compensated and the cooling fan will continuously operate. See the section on RTS compensation on page 56. BatTooHot The battery temperature sensor has detected a battery temperature of over 50°C. The FLEXmax will stop charging the battery and wait for the battery to cool below 50°C. Charged There is an external DC source other than PV keeping the battery above the Float voltage set point (see page 32). The FLEXmax will stop charging because it is not needed. The display may also appear when the cycle is transitioning from Absorbing (upper target voltage) to Floating (lower voltage). EQ The charger is in a cycle of equalization. (See page 48.) This is the time elapsed in hours and minutes since the BATTERY EQUALIZE VOLTS set point was met. If this set point is not maintained, the controller will revert back to MPPT EQ. (See page 29.) The EQ timer will pause until the batteries are regulated at the BATTERY EQUALIZE VOLTS set point again. The paused time can be viewed in the End-of-day Summary screen (see page 24). EQ Done Once the set EQ time (between 1 and 7 hours) has successfully completed, the FLEXmax will transition to Float stage. EQ Done will be displayed either until a button is pressed or the next morning’s wakeup. The FLEXmax will transition to Float stage at the end of the completed equalization cycle. 900-0009-01-00 Rev B 27 Operation EX-Absorb There is an external DC source other than PV keeping the battery above the Absorbing voltage set point. The FLEXmax will stop charging because it is not needed. Floating The FLEXmax is in the Float stage of a three-stage cycle, regulating the battery voltage at the Float voltage set point. This stage is temperature compensated. (See page 103.) If the battery voltage drops below the Float voltage, the FLEXmax will employ the MPPT function to draw more power from the PV array. (This may occur if the batteries are powering loads.) If this happens, the operating mode will change to MPPT Float. (See below.) GT Mode The FLEXmax is in Grid-Tie mode. In a system with an OutBack grid-interactive inverter, a HUB, and a system display, the FLEXmax will display GT Mode, if and only if, the inverter is in Sell mode and the FLEXmax is in the MPPT BULK or MPPT FLOAT modes. This message also indicates that Grid-Tie mode communication has been established between the inverter and charge controller. GT must be selected in the MPPT Mode advanced menu in order to be viewed. (See page 53.) High Voc This indicates the PV array’s open-circuit voltage is too high for the controller to safely operate (> 145 Vdc). This should only occur with systems using 72 Vdc nominal PV arrays in very cold temperatures (below -15°C / 5°F). The FLEXmax will automatically restart operation once the PV array’s open-circuit voltage falls to a safe level (145 Vdc or lower). CAUTION: Equipment Damage Voltages in excess of 150 Vdc are likely to damage the FLEXmax controller. The PV array should be designed to avoid ever reaching these voltages. Low Light or Snoozing A Low Light or Snoozing mode indicates that the PV voltage is high enough to activate the FLEXmax, but there is not enough current available to charge. During the initial tracking (see Wakeup and Tracking), if it is determined to be too late (or too early) in the day, the FLEXmax will display Low Light for a few seconds and then display Snoozing for five minutes (default). This reduces energy usage and unnecessary powering of the FLEXmax. This message is also displayed in extremely cloudy weather. MPPT Bulk This is a Maximum Power Point Tracking mode which harvests the maximum wattage available from the PV array. The controller is trying to regulate the battery voltage towards the Absorbing voltage set point. Normally the charge controller enters this mode at the beginning of the day or when a new charge cycle begins. The controller may also enter this stage if there is not enough PV energy to maintain a different stage, such as Absorbing. See page 26 for more information. MPPT Float This is a Maximum Power Point Tracking mode which harvests the maximum wattage available from the PV array. The controller is trying to regulate the battery voltage towards the Float voltage set point. Normally, the charge controller enters this mode if it was in the Floating mode (see above) and there was not enough energy to maintain the battery voltage. 28 900-0009-01-00 Rev B Operation MPPT EQ The equalization cycle has started and the charge controller is trying to regulate the batteries at the BATTERY EQUALIZE VOLTS set point. Once this voltage has been reached, the displayed mode will change to EQ. Before equalizing, battery loads should be turned off and the battery should be charged so the charge controller can quickly reach the EQ voltage set point. Otherwise, the charge controller may have difficulty reaching or maintaining the equalization process. Equalization is not battery temperature compensated. New Voc The FLEXmax is measuring a new open-circuit panel voltage (Voc). This mode tells the user that external conditions have changed. After displaying this message, the charge controller will enter Tracking mode to perform power point tracking again. OvrCurrent This condition occurs if more than 6 amps flows from the battery to the FLEXmax, or if more than 100 amps is drawn from the FLEXmax by the battery. To reinitiate power production, press <RSTRT> in the Misc menu (see page 51). If this continues to occur, the unit may be malfunctioning. Over Temp The FLEXmax is too hot. If this message appears, carefully check to see if the heat sink is extremely hot. To help control its operating temperature, avoid installing the FLEXmax in direct sunlight. Re-Cal There are certain conditions that can confuse the current measuring method in the FLEXmax. If this happens, the FLEXmax will temporarily stop and re-calibrate. This may happen because of high temperatures or current flowing from the battery. After displaying this message, the charge controller will enter Tracking mode to perform power point tracking again. Sleeping The PV voltage is two volts less than the battery voltage. This normally appears at night, when no PV energy is available. This may also appear during the day when the FLEXmax is transitioning between certain states, or due to other conditions. After three hours of Sleeping, the FLEXmax will transition to Zzzzz... mode. Sys Error This indicates an internal non-volatile memory error. The unit will stop operating when this message is displayed. Call OutBack Technical Support if this message appears (+1.360.618.4363). Tracking In Tracking mode, the FLEXmax is doing an initial tracking of the panel voltage from Voc towards battery voltage after wakeup. This is also displayed when the controller transitions from a target set point (Absorbing, Floating, or EQ) to the MPPT state (MPPT Bulk, MPPT Float, or MPPT EQ). 900-0009-01-00 Rev B 29 Operation Unloaded The battery terminals have become disconnected. This may mean that the battery circuit breaker breaker has tripped. It can also appear if the nominal battery voltage is set too low. Wakeup As the PV open circuit voltage (Voc) rises above the battery system voltage by two volts, the FLEXmax prepares to deliver power to the batteries, although it does not perform MPPT in this mode. During this period (initial tracking), the FLEXmax is calculating the PWM duty cycles, turning on power supply voltages in the proper sequences, and making internal calibrations. It also measures a new Voc at this time. In Wakeup, the daily statistics of a single FLEXmax (amp-hours, kilowatt-hours, etc.), will accumulate into the total statistics. The daily statistics and the end-of-day summary will clear, and the controller will begin logging a new “day”. A FLEXmax combined with a HUB and a MATE will log this information at midnight. On the MATE3, the data logging will occur at the interval scheduled in the MATE3 data logging parameters. Zzzzz... The FLEXmax will display Zzzzz... after 3 hours of continuous Sleeping. This transition indicates that the controller recognizes it is night. It will perform Wakeup when voltage is available (see above). Initial Operation Status Screen In Out 113.6V 12.5V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Status Screen In Out 000.0V 12.5V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Turn the PV input circuit breaker ON. The FLEXmax automatically detects the PV input voltage. The FLEXmax enters Wakeup, transitions to Tracking, and prepares to charge the batteries by tracking the maximum power point of the solar array. During the initial tracking, the input PV source is gradually loaded from the open-circuit voltage (Voc) to ½ of the Voc. Within this range, the FLEXmax seeks the maximum power point. When the FLEXmax goes into Re-Cal, Auto Restart, or Wakeup, modes, among other conditions, it performs an initial tracking. If PV voltage registers 000V when the PV circuit breaker is ON, check the polarity of the PV connections. Figure 15 Initial Operation Changing the Settings on the FLEXmax Accessing the Main Menu The main menu allows the user to adjust and calibrate the FLEXmax for maximum performance. Main Menu Status Screen From the status screen, press SK1 to open the main menu screen. To return to the status screen from the main menu, press <EXIT> (also SK1). Figure 16 30 In Out 113.6V 12.5V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH Sleeping Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Accessing the Main Menu 900-0009-01-00 Rev B Operation Main Menu Map Main Menu From the main menu, a user can choose among the following FLEXmax functions by aligning the arrow next to the desired selection. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO <EXIT> returns to the Status screen. <> moves the cursor to the left. <> moves the cursor to the right. <GO> goes to the setup screen for the chosen option. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger—CHARGER SETUP Adjusts the Current Limit, Absorbing, and Float recharging voltage set points. See page 32 for details. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Aux—AUX OUTPUT CONTROL Provides a secondary control circuit for a vent fan, error alarm, and other system-related additions. See page 33 for details. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Light—BACKLIGHT CONTROL Adjusts the backlighting of LCD screen and soft key buttons. See page 47 for details. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO EQ—BATTERY EQUALIZE Activates battery equalization recharging (manually or automatically). See page 48 for details. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Additional settings and service information. See page 50 for details. Advanced —ADVANCED MENU Optimizes/fine-tunes the charge controller. See page 52 for details. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Logging—DATA LOGGING Displays recorded power production information. See page 60 for details. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO STATS—STATISTICS Displays recorded peak system information and cumulative kilowatt-hours and amp-hours. See page 61 for details. Figure 17 900-0009-01-00 Rev B Misc—MISCELLANEOUS Main Menu 31 Operation Charger Screen Charging settings should follow the battery manufacturer's recommendations. This screen allows changes to the recharging voltage set points if the default settings do not match the manufacturer's recommendations. (For an explanation of battery charging, see pages 102 and 103). Current Limit Absorbing Float The default charger output current limit setting is: 80 amps for the FM80, and 60 amps for the FM60. This setting is adjustable from 5-80 amps. IMPORTANT: Check the battery manufacturer’s recommendations for the optimal charging settings for the type of batteries being used. An appropriate circuit breaker, or overcurrent device, must be used between the battery and the FLEXmax. If a battery remote temperature sensor (RTS) is used, set the Absorbing and Float setting voltage based on a 25°C/77°F setting. RTS compensated voltage values can be viewed in the Advanced menu screen under the RTS Compensation heading. Main Menu To access the Charger screen and adjust the settings: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 1. From the main menu, press the <> or <> soft key to move the to the left of the Charger function. 2. Press <GO> to open the Charger screen. The indicates which set point is selected. 3. Press <> to move the to the set point that needs to be changed. 4. Press <+> to increase the value or (–) to decrease the value. Charger Screen Current Limit 80A Absorbing 14.4V Float 13.8V + EXIT To Exit: Figure 18 32 Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Charger Setup Menu 900-0009-01-00 Rev B Operation Aux Screens The AUX (Auxiliary) is a secondary control circuit — essentially, a small power supply that provides a 12 Vdc output current (up to 200 milliamps/2.4 watts) to an isolated load. It is either ON (Active High) with 12 Vdc available at the output or OFF (Active Low) with 0 Vdc at the output. It can also be set to AUTO, so that it activates when certain criteria are met. The AUX output can respond to specific criteria and control cooling fans, vent fans, load diversion, fault alarms, and automatic generator control. In some cases, such as the PV Trigger, Night Light, or Diversion:Relay applications, the polarity of the output can be reversed so that a lack of power activates the output. This function is controlled through the Aux Polarity screen in the ADVANCED MENU. (See page 59.) NOTE: Diversion:Relay and Diversion:Solid St can be used for AC coupling applications. The AUX output can also be controlled externally through the system display. See the Owner's Manual for the system display (if used) for details. Only one AUX MODE can operate at a time (even if other modes have been preset). See Figure 27, page 45, for an auxiliary setup wiring diagram example. Table 3 Mode Name Vent Fan Aux Mode Functions Function/Purpose Function: When the threshold voltage set point is exceeded, the AUX output will change state for at least 15 seconds. If the set point continues to be exceeded, the output will remain in that state until the voltage falls below the set point. Set Points Aux Polarity Threshold Voltage Not Available Threshold Voltage Active High: Activates the output when the voltage exceeds the set point. Once the voltage decreases below the threshold voltage, the AUX output will remain in that state for another 15 seconds. It will then deactivate. Purpose: This mode is intended to operate a vent fan for a battery enclosure to ventilate hydrogen gas from the enclosure. PV Trigger Function: When the threshold voltage set point is exceeded, the AUX output will activate. When the threshold voltage decreases below the voltage set point, the output will remain active for the duration of the hold time set by the user. Hold Time Active Low: Deactivates the output when the voltage exceeds the set point. Purpose: This mode is intended to operate an alarm, or relay that disconnects the PV array, when PV input exceeds the threshold voltage set by the user. The mode deactivates the alarm or PV disconnect after the time set point has been reached. NOTE: Do not exceed 150 Vdc or the FLEXmax could be damaged. 900-0009-01-00 Rev B 33 Operation Table 3 Mode Name Error Output Aux Mode Functions Function/Purpose Function: When the voltage decreases below the threshold voltage for 10 minutes or more, the AUX output will change state. Set Points Aux Polarity Threshold Voltage Not Available Threshold voltage Active High: Activates for a set amount of time when the voltage drops below the threshold for a set amount of time. Purpose: This mode is useful for monitoring remote sites. It is intended to signal when the charge controller has not charged the batteries for 26 hours or more or if the battery voltage has fallen below the threshold voltage for more than 10 minutes. When set as Active Low, it can activate an alarm by sending a signal through a modem to a computer to alert the operator of the problem. Night Light Function: When the voltage drops below the threshold voltage set point for the amount of time set in the Hysteresis time, the AUX output changes states and remains in that state for the amount of time set for the ON time. ON Time Hysteresis Time Purpose: This mode is intended to illuminate a user-provided, low wattage light for as long as the charge controller remains in Sleep mode or for the ON time set by the user. Float Function: When the FLEXmax is in the Float stage, the output activates to power a load. Active Low: Deactivates for a set amount of time when the voltage drops below the threshold for a set amount of time. None Not Available Threshold Voltage Active High: Controls an auxiliary load to divert power away from the batteries when a wind or hydroelectric turbine is connected directly to the batteries. Purpose: This mode is intended to power a load when the FLEXmax is in the Float stage of charging the batteries. Diversion: Relay Function: When the battery voltage exceeds the threshold voltage, the AUX output changes state. Often used with wind or hydroelectric sources. Time Purpose: This mode is intended to divert power from the batteries to prevent overcharging by activating a diversion load at the appropriate time. Diversion: Solid St Function: When the battery voltage exceeds the threshold voltage, the AUX output goes into pulse-width modulation at a rate of 200 Hz. Often used with wind or hydroelectric sources. Active Low: Deactivates an auxiliary load to stop diverting from batteries. Threshold Voltage Not Available Time Purpose: This mode is intended to divert power from the batteries to prevent overcharging by operating a diversion load at the appropriate PWM level. Recommended for use with a solid-state relay for fast and precise load control. 34 900-0009-01-00 Rev B Operation Table 3 Mode Name Low Battery Disconnect Aux Mode Functions Function/Purpose Set Points Function: When the battery voltage falls below the threshold disconnect voltage, the AUX output activates. When the battery voltage rises above the threshold reconnect voltage, the AUX deactivates. Purpose: Threshold Voltage for disconnect Aux Polarity Not Available Threshold voltage for reconnect Time delay This mode is intended to operate a relay to turn off loads and save battery capacity. Remote Allows an OutBack system display to control the AUX output (see the system display manual for details). None Not Available AUX MODE Screen Navigation Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To access the AUX MODE screen and adjust the settings: 1. From the main menu, press <> or <> to move the to the left of Aux. 2. Press <GO> to open the Aux screen. 3. Press <NEXT> to cycle through the available auxiliary modes. 4. Press <MODE> to cycle through the mode set points ON, OFF, or AUTO. In AUTO mode, the function will automatically activate when a user-determined value is met and deactivate (or shut down) when other conditions are met, such as a certain amount of time passing. 5. Press <SET> to select the set point(s) (if available). 6. Press <EXIT> once to return to the main menu. 7. Press <EXIT> twice to return to the status screen. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE Screen AUX MODE Night Light Output: Off EXIT NEXT SET Off MODE NOTE: If more than 10 minutes have passed since any activity, the PASSWORD screen becomes active, requiring the user to reenter the password (141). Figure 19 900-0009-01-00 Rev B AUX MODE Name AUX MODE Night Light Output: Off Off EXIT NEXT SET MODE Aux Polarity See page 59. AUX MODE Set Point Aux Screen Navigation 35 Operation Vent Fan (AUX Mode) This mode is intended to operate a vent fan for a battery enclosure which helps ventilate hydrogen gas from the enclosure. If the voltage remains above the threshold voltage set point, the vent fan will remain active. When the voltage falls back below the set point, the vent fan will continue for another 15 seconds, then turn off. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE Vent Fan Output: Off EXIT NEXT SET To set the mode for Vent Fan: 1. From the main menu, press <> or <> to move the to the left of Aux. 2. Press <GO> to open the AUX MODE screen. 3. The Vent Fan screen should be the first default screen to display. If any other mode screen is displayed, press <NEXT> to cycle through the available modes until Vent Fan is displayed again. 4. Press <MODE> to switch between ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. Off MODE <NEXT> advances to the next AUX MODE screen. AUX MODE Vent Fan Output: Off EXIT NEXT SET To change the set points for Vent Fan: Off MODE 1. Press <SET> to advance to the set point screen. 2. Press <VOLT> to advance to the VENT FAN VOLTS screen. 3. Press <-> or <+> to increase or decrease the value. 4. Press <BACK> to return to the Vent Fan set point screen. 5. Press <EXIT> to return to the AUX Mode screen. AUX MODE Vent Fan EXIT VOLT VENT FAN VOLTS > 14.4 BACK - + Figure 20 36 To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Setting the Vent Fan Aux Mode 900-0009-01-00 Rev B Operation PV Trigger (AUX Mode) This mode is intended to operate an alarm, or relay that disconnects the PV array, when PV input exceeds the threshold voltage set by the user. The mode turns off the alarm or PV disconnect after the PV voltage decreases below the threshold for a time period that is set by the user. CAUTION: Hazard to Equipment Do not exceed 150 Vdc or the FLEXmax could be damaged. To set the mode for PV Trigger: Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 1. From the main menu, press <> or <> to move the to the left of Aux. 2. Press <GO> to open the AUX MODE screen. 3. Press <NEXT> until PV Trigger is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through ON, OFF, or AUTO. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE PV Trigger Output: Off EXIT NEXT SET ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. Indicates Aux Polarity is Active High Off MODE <NEXT> proceeds to the next AUX MODE screen. AUX MODE PV Trigger Output: Off EXIT NEXT SET To change the set points for PV Trigger: Off MODE 1. Press <SET> to advance to the set points screens; <VOLT> and <TIME>. 2. Press <-> or <+> to increase or decrease the values. 3. Press <BACK> to return to the set point screen. 4. Press <EXIT> to return to the AUX Mode screen. AUX MODE PV Trigger EXIT TIME VOLT Hold Time Sec 01.1 BACK - + Figure 21 900-0009-01-00 Rev B PV VOLTS > 140 BACK - To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. + Setting the PV Trigger Aux Mode 37 Operation Error Output (AUX Mode) This mode is useful for monitoring remote sites. It is intended to signal when the charge controller has not charged the batteries for 26 hours or more or if the battery voltage has fallen below the threshold voltage for more than 10 minutes. The 26-hour timer can be viewed. When set as Active Low, it can operate an alarm by sending a signal through a modem to a computer to alert the operator of the condition. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To set the mode for Error Output: 1. From the main menu, press <> or <> to move the to the left of the Aux function. 2. Press <GO> to open the AUX MODE screen. 3. Press <NEXT> until ERROR OUTPUT is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. AUX MODE ERROR OUTPUT Output: On On EXIT NEXT SET MODE <NEXT> proceeds to the next AUX MODE screen. AUX MODE ERROR OUTPUT Output: Off On EXIT NEXT SET MODE NOTE: To advance to the timer screen, press <SET>. This timer counts up to the 26-hour limit before the AUX output is activated. The voltage set point for this mode can also be changed. To change the set point for ERROR OUTPUT: AUX MODE ERROR OUTPUT 01 hrs EXIT VOLT 1. Advance to the timer screen as noted above. 2. Press <VOLT> to advance to the ERROR LOW BATT VOLTS screen. 3. Press <-> or <+> to increase or decrease the value. 4. Press <BACK> to return to the ERROR OUTPUT set point screen. 5. Press <EXIT> to return to the AUX Mode screen. ERROR LOW BATT VOLTS < 11.5 To Exit: BACK - + Figure 22 38 Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Setting the Error Output Aux Mode 900-0009-01-00 Rev B Operation Night Light (AUX Mode) This mode is intended to operate a user-provided, low wattage light for as long as the charge controller remains in Sleep mode or for the ON time set by the user. OFF is the default value. Main Menu To set the mode for Night Light: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 1. From the main menu, press <> or <> to move the to the left of the Aux function. 2. Press <GO> to open the AUX MODE screen. The indicates that the mode supports polarity. See page 59. 3. Press <NEXT> until Night Light is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. Indicates Aux Polarity is Active High AUX MODE Night Light Output: Off Off EXIT NEXT SET MODE <NEXT> proceeds to the next AUX MODE screen. AUX MODE Night Light Output: Off EXIT NEXT SET To change the set points for Night Light: Off MODE 1. Press <SET> to advance to the set point screens. <HYST>, <VOLT>, and <TIME>. 2. Press <-> or <+> to increase or decrease the values. 4. Press <BACK> to return to the ERROR OUTPUT set point screen. 5. Press <EXIT> to return to the AUX Mode screen. AUX MODE Night Light EXIT To Exit: HYST TIME VOLT Night Light ON Hysteresis Time Minutes 000 BACK + OFF Night Light OFF Hysteresis Time Minutes 000 BACK + Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Night Light On Time Hours 23 BACK - + Adjusts the amount of time the night light remains on. Figure 23 900-0009-01-00 Rev B Night Light Threshold Voltage 010 BACK + Adjusts the threshold of the voltage that triggers the function. Setting the Night Light Mode 39 Operation Float (AUX Mode) This mode is intended to operate a load when the FLEXmax is in the Float stage of charging the batteries. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To set the mode for Float: 1. From the main menu, press <> or <> to move the to the left of Aux. 2. Press <GO> to open the AUX MODE screen. 3. Press <NEXT> until Float is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through the mode set points ON, OFF, or AUTO. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE Float Output: Off EXIT NEXT SET ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. To Exit: Off MODE Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. <NEXT> proceeds to the next AUX MODE screen. Figure 24 40 Setting the Float Mode 900-0009-01-00 Rev B Operation Diversion (AUX Mode) When external DC sources (wind, hydroelectric) are directly connected to a battery bank, any excess power should be sent to a diversion load, such as a heating element, using a mechanical relay or solid-state relay. In Diversion mode, the user programs set points — from -5.0 volts to 5.0 volts relative to the Absorbing, Float, and EQ voltages — to activate the AUX output. The Diversion AUX mode can be active (ON) when the battery voltage is raised above one of these set points for a certain amount of time or inactive (OFF) when it falls below. To control a mechanical relay for basic on/off switching of a standard diversion load, follow the instructions in Figure 25 (both pages). To control a solid-state relay for PWM switching and precise control of a load, follow the instructions in Figure 26 (both pages). This application should not be used with a mechanical relay. It requires the use of a resistive load and should not be used with other sorts of loads. For a wiring diagram illustrating how to connect this function, see Figure 27. Diversion:Relay Mode Main Menu IMPORTANT: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO If using wind or hydroelectric turbines, keep the charge controller’s diversion voltage slightly above the Absorbing and Float voltage settings for efficient functioning. To set the mode for Diversion:Relay: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE Diversion:Relay Output: Off EXIT NEXT SET Off MODE 1. From the main menu, press <> or <> to move the to the left of Aux. 2. Press <GO> to open the AUX MODE screen. 3. Press <NEXT> until Diversion:Relay is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through the mode set points ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. Continued on next page.... <NEXT> proceeds to the next AUX MODE screen. Figure 25 900-0009-01-00 Rev B Setting the Diversion:Relay AUX Mode (Part 1) 41 Operation ...continued from previous page. AUX MODE Diversion:Relay Output: Off EXIT NEXT SET To change the set points for Diversion:Relay: Off MODE 1. Press <SET> to advance to the set point screens; <VOLT> and <TIME>. 2. Press <TIME> to advance to the Time screen. This allows the user to adjust the minimum time the AUX output is active after the battery voltage falls below the hysteresis voltage. 3. Press <-> or <+> to increase or decrease the Hold time values. 4. Press <DLY+> to increase the Delay Time. 5. Press <BACK> to return to the Diversion:Relay TIME and VOLT screen. 6. Press <VOLT> to move into the Relative Volts screen. 7. Press <-> or <+> to increase or decrease the values. 8. Press <HYST> to select the hysteresis value. 9. Press <BACK> to return to the main Diversion;Relay TIME and VOLT screen. 10. From the Diversion:Relay screen, press <EXIT> to return to the AUX MODE screen. To Exit: AUX MODE Diversion:Relay EXIT Hold 01.0 BACK Time Seconds + Delay 00 DLY+ Hold time shows how long the AUX output stays active after the battery voltage has fallen below the HYST (hysteresis) set point. The user can adjust the Hold time from 0.1 to 25 seconds. The Delay time shows how long the battery voltage must be above the Relative Volts before the AUX mode is activated. It can be adjusted from 0 to 24 seconds, but is rarely required. TIME VOLT Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Absorb--Float--EQ Relative Volts 0.0 00.2 BACK + HYST Use this screen to establish the set points for starting and ending the AUX mode relative to the Absorb, Float, and EQ voltages. The <HYST> (hysteresis) set point establishes when the AUX mode becomes inactive after the battery voltage falls below the Relative Volts voltage minus the hysteresis value. Pressing the <BACK> soft key returns to the AUX MODE Diversion: Relay TIME and VOLT screen. Figure 25 42 Setting the Diversion:Relay Mode (Part 2) 900-0009-01-00 Rev B Operation Diversion:Solid St (AUX Mode) Main Menu IMPORTANT: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE Diversion:Solid St Output: Off Off EXIT NEXT SET MODE <NEXT> proceeds to the next AUX MODE screen. If using wind or hydroelectric turbines, keep the charge controller’s diversion voltage slightly above its Absorb and Float voltage settings for efficient functioning. Do not use Diversion:Solid St with a mechanical relay. The PWM action could cause irregular relay activity. Diversion:Solid St requires the use of a purely resistive load. The PWM action may work poorly with mechanical loads. To set the mode for Diversion:Solid St: 1. From the main menu, press <> or <> to move the to the left of Aux. 2. Press <GO> to open the AUX MODE screen. 3. Press <NEXT> until the Diversion:Solid St mode is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. Continued on next page... Figure 26 900-0009-01-00 Rev B Setting the Diversion:Solid St AUX Mode (Part 1) 43 Operation Continued from previous page… To change the set points for Diversion:Solid St: AUX MODE Diversion:Solid St Output: Off Off EXIT NEXT SET MODE 1. Press <SET> to advance to the set point screens; <VOLT> and <TIME>. 2. Press <TIME> to advance to the Time screen. This allows the user to adjust the minimum time the AUX output is active after the battery voltage falls below the hysteresis voltage. 3. Press <-> or <+> to increase or decrease the Hold time values. 4. Press <DLY+> to increase the Delay time. 5. Press <BACK> to return to the Diversion:Solid St TIME and VOLT screen. 6. Press <VOLT> to move into the Relative Volts screen. 7. Press <-> or <+> to increase or decrease the values. 8. Press <HYST> to select the hysteresis value. 9. Press <BACK> to return to the Diversion:Solid St Time and Volt screen. 10. From the Diversion:Solid St screen, press <EXIT> to return to the AUX MODE screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. AUX MODE Diversion:Solid St EXIT Hold 01.0 BACK Time Seconds + Delay 00 DLY+ Hold time shows how long the AUX mode stays active after the battery voltage has fallen below the HYST (Hysteresis) set point. The user can adjust the Hold time from 0.1 to 25 seconds. The Delay Time shows how long the battery voltage must be above the Relative Volts before the AUX mode is activated. It can be adjusted from 0 to 24 seconds, but is rarely required. Figure 26 44 TIME VOLT Absorb--Float--EQ Relative Volts 0.0 00.2 BACK + HYST Use this screen to establish the set points for starting and ending the AUX mode relative to the Absorb, Float, and EQ voltages. The <HYST> (hysteresis) set point establishes when the AUX mode becomes inactive after the battery voltage falls below the Relative Volts voltage minus the HYST value. Setting the Diversion:Solid St Mode (Part 2) 900-0009-01-00 Rev B Operation Figure 27 900-0009-01-00 Rev B Wiring Diagram for Diversion Load and AUX Wiring 45 Operation Low Battery Disconnect (AUX Mode) This mode disconnects “auxiliary” loads from the batteries in the event of low voltage. These are separate from the usual loads. Auxiliary loads are controlled by the AUX output, usually by a larger relay. When the battery voltage falls below the DISCONNECT VOLTS setting, the AUX loads are disconnected. When the voltage rises above the RE-CONNECT VOLTS, they will be reconnected. Any loads not controlled this way, such as an inverter, may continue discharging the battery. Main Menu To set the mode for Low Battery Disconnect in Aux mode: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 1. From the main menu, press <> or <> to move the to the left of the Aux. 2. Press <GO> to open the AUX MODE screen. 3. Press <NEXT> until the Low Batt Disconnect Mode is displayed in the AUX MODE screen. 4. Press <MODE> to cycle through the mode set points; ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. AUX MODE Low Batt Disconnect Output: Off Off EXIT NEXT SET MODE <NEXT> proceeds to the next AUX MODE screen. AUX MODE Low Batt Disconnect Output: Off Off EXIT NEXT SET MODE AUX MODE Low Batt Disconnect EXIT TIME VOLT To change the set points for Low Battery Disconnect: 1. Press <SET> to advance to the set point screens; <VOLT> and <TIME>. 2. Press <TIME> to advance to the Delay Time Sec screen. 3. Press <-> or <+> to increase or decrease the values. 4. Press <BACK> to return to the main Low Batt Disconnect screen. 5. Press <VOLT> to advance to the DISCONNECT VOLTS screen. 6. Press <-> or <+> to increase or decrease the values. 7. Press <RECON> to advance to the RE-CONNECT VOLTS screen. 8. Press <-> or <+> to increase or decrease the values. 9. Press <DisV> to return to the DISCONNECT VOLTS screen. 10. Press <BACK> to return to the Low Batt Disconnect screen. Delay Time Sec 01 Timer 001 BACK + This is the time period the FLEXmax waits before either activating or deactivating the AUX mode when either the disconnect or reconnect voltages are reached. DISCONNECT VOLTS < 13.6 BACK - + ReCon RE-CONNECT VOLTS > 14.4 BACK - + To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. DisV When the low voltage occurs, the timer shows the seconds remaining before disconnecting. Figure 28 46 Low Battery Disconnect Mode 900-0009-01-00 Rev B Operation Remote (AUX Mode) Remote allows an OutBack system display to control the charge controller's auxiliary output. Some displays may require a certain level of software in order to use this feature. Consult the owner's manual for the system display being used for details. Main Menu To set the mode for Remote: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 1. 2. 3. 4. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO AUX MODE Remote Output: Off EXIT NEXT SET From the main menu, press <> or <> to move the to the left of the Aux. Press <GO> to open the AUX MODE screen. Press <NEXT> until the Remote mode is displayed in the AUX MODE screen. Press <MODE> to cycle through ON, OFF, or AUTO. ON activates the AUX output. OFF deactivates the AUX output. AUTO controls the output according to the criteria of the selected AUX mode. This setting may be required depending on the type of system display being used. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Off MODE The FLEXmax AUX output can be used for the AGS (Advanced Generator Start) function of a system display. Remote must be activated for this to work. The system display must be set to the HUB port used by the FLEXmax. See the system display manual for more information on AGS. If using a MATE, see page 87 of this book. If using a MATE3, see page 73. Figure 29 Setting the Remote Mode Backlight The Backlight selection allows the LCD and soft keys to remain illuminated for up to nine minutes whenever any soft key is pressed. The default setting for this mode is AUTO. Pressing any soft key when the LCD is not illuminated does not change any settings. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To set the mode for Backlight: 1. From the main menu, press <> or <> to move the to the left of Light. 2. Press <GO> to open the Backlight Control screen. 3. Press < MODE> to cycle through ON, OFF, or AUTO. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO BACKLIGHT CONTROL Auto Time 2 Minutes AUTO EXIT + MODE Figure 30 900-0009-01-00 Rev B ON activates the backlight. OFF deactivates the backlight. AUTO activates the backlight on a timer. 4. Press <-> or <+> to increase or decrease the number of minutes (up to 9) for the Auto Time mode. 5. Press <EXIT> twice to return to the status screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Operating the Backlight 47 Operation EQ – Battery Equalize Equalization is a controlled overcharge that is part of regular battery maintenance. Equalization brings the batteries to a much higher voltage than usual and “simmers” them for a period of time. This has the result of removing inert compounds from the battery plates and reducing stratification in the electrolyte. Equalization follows the same pattern as standard three-stage charging. However, instead of the Absorption voltage set points, it is controlled by the Battery Equalize Volts settings. The time is controlled by the Battery Equalize Time setting. Equalization is normally performed only on flooded lead-acid batteries. The schedule for equalization varies with battery use and type, but it is usually performed every few months. If performed correctly, this process can extend battery life by a considerable amount. CAUTION: Battery Damage Do not equalize any sealed battery types (VRLA, AGM, Gel, or other) unless approved by the manufacturer. Some batteries may suffer severe damage from equalization. Contact the battery manufacturer for recommendations on equalization voltage, duration, schedule, and/or advisability. Always follow manufacturer recommendations for equalization. MAIN Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO BATTERY EQUALIZE Volts 15.0 EXIT NEXT -EQV +EQV BATTERY EQUALIZE Time 01 Hours EXIT NEXT -HRS +HRS BATTERY EQUALIZE 1 Hours 15.0 Volts Check water level BACK AUTO START STOP To change the EQ mode settings: 1. From the main menu, press <> or <> to move the to the left of EQ . 2. Press <GO> to open the BATTERY EQUALIZE Volts screen. 3. Press <-EQV> to decrease the value. 4. Press <+EQV> to increase the value. 5. Press <NEXT> to advance to the Battery Equalize Time screen. 6. Press <-HRS> to decrease the value. 7. Press <+HRS> to increase the value. 8. Press <NEXT> to advance to the Battery Equalize Start screen. 9. Choose one of the following equalization modes: Press <START> to start a manual equalization charge. Press <STOP> to stop an equalization charge. Press <AUTO> to view the auto equalization screen. See Figure 32 for details. 10. Press <BACK> to return to the EQ screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 31 48 Using Equalization 900-0009-01-00 Rev B Operation Automatic Equalization Mode To enable an automatic equalization mode, an interval must be set for the number of days to pass between equalization cycles. This interval can be between 1 to 250 days. The default equalization interval setting is 000 which disables this feature. The Equalization Interval screen allows the user to set the interval between equalization cycles. It also displays how many days of the interval has passed. The COUNT value will be cleared to 000 when an equalization cycle is started, manually stopped, or if the charge controller has been powered off. Equalization Interval Screen Days of the interval that have elapsed COUNT 000 EQ INTERVAL 000 EXIT -DAY +DAY EQ INTERVAL (1 to 250) BATTERY EQUALIZE START Screen BATTERY EQUALIZE 1 Hours 15.0 Volts Check water level BACK AUTO START STOP To enable an automatic EQ cycle: 1. Press <AUTO> to display the equalization interval screen. 2. Use <-DAY> or <+DAY> to set the number of days between each equalization cycle. 3. Press <BACK> to return to the status screen. Equalization Interval Screen COUNT 000 EQ INTERVAL 000 EXIT -DAY +DAY To Exit: Press <EXIT> once to return to the EQ screen. Status Screen In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH EQ-MPPT In Out 11.6V 13.8V 0.000 kW AUX: OFF 0.0 A 0.0 A 0.0 kWH EQ 0:00 In Out 0.0 A 0.0 A 0.0 kWH EQ DONE 11.6V 13.8V 0.000 kW AUX: OFF On the Status Screen: EQ-MPPT will display to indicate the FLEXmax is trying to reach the target equalize set point. EQ 0:00 in Hours:Minutes will display after the equalize set point is reached. After recharging, an EQ DONE message displays and a Float cycle begins. EQ DONE is displayed until (1) any soft key is pressed, or (2) a new day occurs for systems using an OutBack system display. The incomplete equalization cycle continues into the next day unless the FLEXmax is powered off or manually stopped. The remaining EQ time can be viewed in the End-of-day Summary screen (see page 24). Figure 32 900-0009-01-00 Rev B Setting the EQ AUTO Interval 49 Operation Misc Screen There are three Misc screens that provide technical information about the operating state of the system. These are read-only screens and allow for no changes to any of the settings. They do provide the means to wake up the charge controller if it is in Snooze mode. They also provide a means to force the charger into a Bulk or Float stage. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To access the Misc screens: 1. From the main menu, press <> or <> to move the to the left of the Misc function. 2. Press <GO> to open the Misc screen. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Misc Screen #1 GT STATE 255 07 EXIT GT STATE 255 07 EXIT PWM% 50.0 NEXT GT STATE 255 07 EXIT NEXT GT STATE 255 07 EXIT NEXT GT STATE 255 07 EXIT RSTRT Press <EXIT> to return to the main menu. Each MPPT operation has a state which is indicated by a number. These numbers are for engineering purposes and are not significant in normal use. This indicates the percentage of "on" time for the FETs as they are performing pulse width modulation. ChgT 005 RSTRT PWM% 50.0 NEXT ChgT 005 RSTRT PWM% 50.0 NEXT ChgT 005 A number below GT means the FLEXmax is in grid-tie mode and communicating with an OutBack grid-interactive inverter. These numbers are for engineering purposes and are not significant in normal use. If the inverter is not grid-interactive, then this number will read 000. (See pages 54 and 108.) ChgT 005 RSTRT PWM% 50.0 PWM% 50.0 The charge timer (ChgT) counts up to the Absorb time limit when the charger is in the Absorb stage. See pages 26 and 55. ChgT 005 RSTRT Misc Screen #1 GT STATE 255 07 EXIT Figure 33 50 NEXT PWM% 50.0 ChgT 005 Press <NEXT> to continue to the Force Bulk/Float screen. RSTRT Miscellaneous Screen #1 900-0009-01-00 Rev B Operation Misc Screen #1 GT STATE 255 07 EXIT PWM% 50.0 NEXT To bring the charge controller out of Snoozing mode: ChgT 005 RSTRT 1. Press <RSTRT>. 2. Press <EXIT> to return to the main menu. Misc Screen #1 GT STATE 255 07 EXIT PWM% 50.0 NEXT To force the charger into a Bulk or Float charge cycle: ChgT 005 1. Press <NEXT>. 2. Select either a Float or Bulk charge cycle. Forcing a Float or Bulk recharge will end an EQ cycle. See page 26 for details on these modes. RSTRT Force Bulk/Float Screen FORCE NEXT FLOAT BULK EXIT 3. Press <FLOAT> to force a Float charge. Press <BULK> to force a Bulk charge. Press <EXIT> to return to the main menu, or press <NEXT> to view the next miscellaneous screen. Misc Screen #2 PCB 512 Target 14.4v EXIT BACK PCB 512 Target 14.4v EXIT BACK PCB 512 Target 14.4v EXIT BACK PCB 512 Target 14.4v EXIT BACK PCB 512 Target 14.4v EXIT BACK Press <BACK> to return to the Force Bulk/Float screen. Press <EXIT> twice to return to the main menu. BTMP CFB 255 0712 PCB represents the temperature of the internal components. It is used to control the cooling fan. These values are in digital counts, not degrees. The lower the number, the higher the temperature. (25°C is approximately a value of 525.) BTMP CFB 255 0712 The target voltage the controller is trying to reach. This will depend on the active stage of the charger and the set target value for that stage. BTMP CFB 255 0712 BTMP CFB 255 0712 Figure 34 900-0009-01-00 Rev B BTMP CFB 255 0712 BTMP is a battery temperature sensor reference value, used to compensate the charging voltage. The range is 0 to 255. These values are in digital counts, not degrees. An X next to this value indicates an external RTS is being used in a system with a HUB and system display. CFB represents Current FeedBack. This is the output value of the internal current sensor and is used to calculate output amps and watts to track the maximum power point of the array. Miscellaneous Screen #2 51 Operation Advanced Menu The Advanced menu allows fine-tuning of the FLEXmax operations including Snooze periods and Maximum Power Point limits (see page 101). The following modes are available in the Advanced menu. They will appear in the following order. Snooze Mode Wakeup MPPT Mode Park Mpp Mpp Range Limit % Voc Absorb Time Rebulk Voltage Vbatt Calibration RTS Compensation Auto Restart Aux Polarity Reset to Defaults? Main Menu To Access the Advanced Menus: Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Figure 35 1. From the main menu, press <> or <> to move the to the left of Advanced. 2. Press <GO> to open the first Advanced menu screen. 3. Press <NEXT> to cycle through the available modes. The Snooze Mode screen should be the first screen to display. 4. Press <EXIT> to return to the status screen. Accessing the Advanced Menu Snooze Mode (Advanced Menu) Snoozing occurs if the charging current does not reach the user-selected cutoff current set point as shown in this screen. Snooze Mode ADVANCED MENU Snooze Mode < 0.6 amp EXIT NEXT AMP To adjust the set point in the Snooze Mode screen: 1. Navigate to the Snooze Mode screen through the ADVANCED MENU as instructed in Figure 35. 2. Press <AMP> to adjust the amp setting. Amp values increments include: 0.2, 0.4, 0.6, 0.8 and 1.0. 3. Press <NEXT> to advance to the Wakeup Mode screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 36 52 Snooze Mode 900-0009-01-00 Rev B Operation Wakeup Mode (Advanced Menu) Wakeup Mode sets the open-circuit voltage (Voc) conditions that cause the charge controller to wake up during Sleep and Snooze modes. Since environmental conditions impact the open-circuit voltage of an array, the Voc can be based on the last measured Voc value. Before changing these values, monitor the system for a week or so using the factory defaults and then gradually adjust the set points. If the set points are set too high, the charge controller might not wake up soon enough or often enough, which means a loss of power production. Wakeup Mode Amp Settings To adjust the set points in Wakeup Mode: ADVANCED MENU Wakeup Mode < 0.6 amp EXIT NEXT AMP 1. Navigate to the Wakeup Mode screen through the ADVANCED MENU as instructed in Figure 35. 2. Press <AMP> to adjust the amp setting. Amp values increment include: 0.2, 0.4, 0.6, 0.8 and 1.0. 3. Press <NEXT> for the voltage settings screen. 4. Press <+VOC> or <-Min> to adjust the voltage and delay settings. Wakeup Mode Voltage Settings ADVANCED MENU Wakeup Mode 1.5V 05m EXIT NEXT +VOC -Min 5. <+VOC> ranges from 1.5 V up to 9.5 V <+MIN> ranges from 5 up to 15 minutes Press <NEXT> for the MPPT Mode screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 37 Wakeup Mode MPPT Mode (Advanced Menu) This screen allows the user to choose from the following modes: Auto Track MPPT mode (default) automatically tracks the PV upon wakeup and then tracks the MPP of the array. If Auto Restart is set to 1 or 2, the charge controller awakes every 1.5 hours and does an initial tracking. (See page 58.) U-Pick % (Voc) MPPT mode allows the user to manually adjust the MPP tracking limit as a percentage of the array's open-circuit voltage (Voc). This percentage is displayed in the Park Mpp % Voc screen along with the current output wattage. (See page 54.) The wattage value changes as the user adjusts the Voc percentage, letting the user lock in the most advantageous percentage value. U-Pick % acquires a new Voc value every 1.5 hours if Auto Restart is set to 1 or 2. To select the MPPT Mode: MPPT Mode ADVANCED MENU MPPT Mode Auto Track EXIT NEXT nonGT MODE 1. Navigate to the MPPT Mode screen through the ADVANCED MENU as instructed in Figure 35. 2. Press <MODE> to choose an MPPT mode. If the system has an OutBack grid-interactive inverter with a HUB and system display, press <nonGT> to change it to <GT>. This will place the charge controllers in GT mode to allow the inverter to sell excess power. 3. Press <NEXT> to view the Park Mpp screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 38 900-0009-01-00 Rev B MPPT Mode – Auto Track 53 Operation GT allows the FLEXmax to work more effectively with a grid-interactive OutBack inverter. This setting automatically raises the charge controller’s Float voltage to equal its Absorption voltage. Since the inverter sells power to maintain its own Float, Absorption, or Sell settings (all of which should be lower than those of the controller), this mode makes it easier for the inverter to sell power. (See pages 50 and 108 for more information on this mode.) NOTE: The charge controller’s Float voltage returns to normal any time the inverter enters PassThru or Silent modes. (See the inverter Operator's Manual for inverter modes.) The Park Mpp screen will be slightly different between Auto Track mode and U-pick mode. In the U-pick mode, the Watts will appear in addition to the %Voc value. MPPT Mode Auto Track MPPT Mode U-pick% ADVANCED MENU MPPT Mode Auto Track EXIT NEXT nonGT MODE ADVANCED MENU MPPT Mode U-pick% EXIT NEXT nonGT MODE Auto Track Park Mpp U-pick% Park Mpp ADVANCED MENU Park Mpp 77 % Voc EXIT NEXT -% +% ADVANCED MENU Park Mpp Watts 0251 77 % Voc EXIT NEXT -% +% Mpp Range Limit % Voc Mpp Range Limit % Voc ADVANCED MENU Mpp Range Limit %VOC Min Max EXIT NEXT 1/2 90% ADVANCED MENU Mpp Range Limit %VOC Min Max EXIT NEXT 1/2 90% To adjust the Park Mpp voltage percentage settings: 1. Press <NEXT> to view the Mpp Range Limit % VOC screen. 2. Choose one of the following options: Press <-%> to decrease the value. Press <+%> to increase the value. 3. Press <NEXT> to advance to the Mpp Range Limit %Voc screen. 4. Press <Min> or <Max> to adjust the MPP range limit. To Exit: The Mpp Range Limit % Voc adjusts the upper range limit of the FLEXmax controller’s maximum power point (MPP) tracking. The default Max MPP voltage limit is set at 90% of the Voc and is normally not adjusted for a PV array. If necessary, the adjustable limits are 80%, 85%, 90%, and 99% of the Voc. Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Press <NEXT> to advance to the Absorb Time Limits screen. Min optimizes the tracking window for MPPT. The default Min setting of 1/2 establishes the lower limit of this window as one-half the Voc. The Min range limit setting may be set to FULL if something other than a PV array is connected to the input of the FLEXmax, such as a hydroelectric turbine (see page 106). However , the input voltage must never exceed 150 Vdc at any time. Figure 39 54 MPPT Mode – U-Pick % 900-0009-01-00 Rev B Operation Absorb Time Limits (Advanced Menu) The amount of time the charge controller stays in the Absorbing stage of charging can be adjusted in the Absorb Time Limits screen. An Absorbing charge stage normally ends when the battery voltage is maintained at the Absorbing set point for the time period set in the Absorb Time Limits screen. Absorb Time is adjustable from 0 to 24 hours (consult the battery manufacturer’s recommendations). When the Absorb Time Limit is reached, the charge controller goes into Float stage and may briefly display Charged, then Float. When the battery voltage drops below the Float voltage set point, the charge controller recharges to maintain this set point, employing the MPPT function in MPPT Float mode. To adjust the set points in the Absorb Time Limits screen: Absorb Time Limits ADVANCED MENU Absorb Time Limits 01.0 hours EXIT NEXT + 1. Navigate to the Absorb Time Limits screen through the ADVANCED MENU as instructed in Figure 35. 2. Use < -> or < + > to adjust the Absorb time from 0.0 to 24.0 hours following the recommendation of the battery manufacturer. 3. Press <NEXT> to advance to the Absorb End Amps screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 40 Absorb Time Limits Screen Absorb End Amps (Advanced Menu) While the battery voltage is at or above the Absorbing voltage target (see page 26) and the Absorb End Amps value is reached for a time delay of 15 seconds, the charge controller will switch to the Float stage. This happens regardless of the charger time minutes as shown in the Misc menu under ChgT (see page 50). The charger timer will be reset to zero. Absorb End Amps ADVANCED MENU Absorb End Amps EXIT NEXT - 00 A + To adjust the set points in the Absorb End Amps screen: 1. Navigate to the Absorb End Amps screen through the ADVANCED MENU as instructed in Figure 35. 2. Use < -> or < + > to adjust the amperage limit following the recommendation of the battery manufacturer. The default value is 00. 3. Press <NEXT> to advance to the Rebulk Voltage screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 41 900-0009-01-00 Rev B Absorb End Amps Screen 55 Operation Rebulk Voltage (Advanced Menu) In the Float stage, if the battery voltage falls below the ReBulk Voltage set point for at least 90 seconds, the FLEXmax will automatically initiate a new charge cycle. To adjust the set points in the Rebulk Voltage screen: Rebulk Voltage 1. ADVANCED MENU Rebulk Voltage 12.0V EXIT NEXT + Navigate to the Rebulk Voltage screen through the ADVANCED MENU as instructed in Figure 35. 2. Use < -> or < + > to adjust the voltage limit following the recommendation of the battery manufacturer. The default values are 12.0 V, 24.0 V, 36.0 V, 48.0V and 60.0 V. 3. Press <NEXT> to advance to the Vbatt Calibration screen. To Exit: Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 42 Rebulk Voltage Vbatt Calibration (Advanced Menu) A quality, calibrated voltmeter will provide even more accurate FLEXmax battery readings if an undesirable voltage drop occurs. When measuring battery voltage, ensure a good connection is made to the four wire lugs. Check the battery temperature compensation voltages if the voltages are much different than expected from the charger setup Absorbing and Float voltage settings. Vbatt Calibration Adjusted Voltage ADVANCED MENU Vbatt Calibration 14.1 V 0.0 V EXIT NEXT + Adjustment Value NOTE: The adjusted voltage value should appear on the status screen. To adjust the set points in the Vbatt Calibration screen: 1. Navigate to the Vbatt Calibration screen through the ADVANCED MENU as instructed in Figure 35. 2. Use < -> or < + > to increase or decrease the value. The voltage will change in increments of 0.1 Vdc. 3. Press <NEXT> to advance to the RTS Compensation screen. To Exit: Figure 43 Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Vbatt Calibration RTS Compensation (Advanced Menu) The RTS Compensation screen allows the user to control the Absorbing and Float voltage limits during charging when using a Remote Temperature Sensor (RTS). The RTS adjusts charging voltage depending on battery temperature. (See page 103 for the amount of compensation per degree.) However, some conditions can make compensation less than optimal, such as extreme weather (hot or cold), or charging restrictions from the battery manufacturer. Therefore, the RTS Compensation screen allows the user to control the limits used by the compensation feature. 56 900-0009-01-00 Rev B Operation For example: During cold weather, a battery often requires a higher charging voltage. Some inverters might not accommodate these higher voltages and can shut down during charging, cutting off power to their loads. During hot weather, limiting the RTS Compensation values assures the voltage stays high enough to charge the batteries instead of dropping too low in reaction to a higher ambient temperature. Battery manufacturer specifications indicate not to exceed a certain voltage or battery damage could occur. In all cases, the batteries should be monitored to ensure they are being charged according to the battery manufacturer’s recommendations. RTS Compensation has two options available. WIDE allows the RTS full control over charging. This option uses the default values for the RTS. LIMIT sets the minimum and maximum voltages for the RTS. Pressing the soft key below each option switches between the two options. When the LIMIT option is visible, a <SET> soft key is available to advance to a screen that allows the user to adjust the settings. RTS Compensation Screen ADVANCED MENU RTS Compensation A 14.1 V F 13.8 V EXIT NEXT WIDE Press <WIDE> to switch to LIMIT. ADVANCED MENU RTS Compensation A 14.1 V F 13.8 V EXIT NEXT LIMIT SET To use the default RTS compensation values: 1. Navigate to the RTS Compensation screen through the ADVANCED MENU as instructed in Figure 35. 2. If WIDE is visible above the soft key, the absorb and float values shown in this screen will be used by the system. To Exit: Press <NEXT> to advance to the Auto ReStart menu. Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Press <LIMIT> to switch back to WIDE. To limit the RTS compensation values: ADVANCED MENU RTS Compensation A 14.1 V F 13.8 V EXIT NEXT LIMIT SET 1. Navigate to the RTS Compensation screen through the ADVANCED MENU as instructed in Figure 35. 2. If WIDE is visible above the soft key, press the <WIDE> soft key to change the display to show LIMIT. 3. Press <SET> to advance to the RTS COMPENSATION limits screen. RTS COMPENSATION Upper LIMIT 14.1 V Upper LIMIT 14.1 V BACK + Press < > until the is next to the limit to be changed. The will switch between the upper and lower limit values each time it is pressed. Press <-> to decrease the value. Press <+> to increase the value. To Exit: Press <BACK> to return to the main RTS Compensation screen. Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 44 900-0009-01-00 Rev B RTS Compensation 57 Operation Auto ReStart (Advanced Menu) This setting allows the user to choose between continuous maximum power point (MPP) tracking, or occasional restarts of the sweeping process. A restart means the controller abandons the existing maximum power point value it was using and “re-sweeps”, or begins gathering new power point data. (See page 101 for more information on MPP tracking.) Auto ReStart has three options available: Mode 0 – Initial sweep only and then continuous MPP tracking. Auto ReStart is disabled. The FLEXmax will continously track the maximum power point without starting over. Mode 1 – Automatic re-sweep every 90 minutes if controller is in an MPPT mode (MPPT Float, MPPT Bulk, etc). This will not reset any counters, charging stages, or statistics. Mode 2 – Automatic re-sweep every 90 minutes if controller is in any charging mode. This will not reset any counters, charging stages, or statistics. Auto ReStart Screen To select an Auto ReStart mode: ADVANCED MENU Auto ReStart MODE 0 EXIT NEXT MODE 1. Navigate to the Auto ReStart screen through the ADVANCED MENU as instructed in Figure 35. ADVANCED MENU Auto ReStart MODE 1 EXIT NEXT MODE 2. Press <MODE> to switch between the three Auto ReStart modes: MODE 0 (default), MODE1, and MODE2. ADVANCED MENU Auto ReStart MODE 2 EXIT NEXT MODE ADVANCED MENU Auto ReStart Mode 0 EXIT NEXT MODE To Exit: Press <NEXT> to advance to the Aux Polarity screen. Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. Figure 45 58 Auto ReStart 900-0009-01-00 Rev B Operation Aux Polarity (Advanced Menu) When the AUX function is ON, 12 volts DC is present at the AUX terminals (Active High). When the AUX function is OFF, 0 volts DC are present at the terminals (Active Low). Aux Polarity allows the user to reverse the availability of this voltage for the Night Light, PV Trigger, or Diversion Relay functions. When one of the these functions has been chosen as the AUX function, an arrow in the right hand corner of the screen will reflect the Aux Polarity state. In Active High, the user establishes certain conditions for these functions. In the Active Low, zero voltage will be available for a function that in Active High would normally have voltage. Aux Polarity Screen To select the mode for Aux Polarity : ADVANCED MENU Aux Polarity Active High EXIT NEXT MODE 1. Navigate to the Aux Polarity screen through the ADVANCED MENU as instructed in Figure 35. 2. Press <MODE> to switch between: Active High or Active Low To Exit: ADVANCED MENU Aux Polarity Active Low EXIT NEXT MODE Press <NEXT> to advance the Reset to Defaults? screen. Press <EXIT> once to return to the main menu. Press <EXIT> twice to return to the status screen. AUX MODE (Active Low) AUX MODE PV Trigger Output: Off EXIT NEXT SET Figure 46 AUX MODE (Active High) OFF MODE AUX MODE PV Trigger Output: Off EXIT NEXT SET OFF MODE Aux Polarity Screen Reset to Defaults? Reset to Defaults? Screen ADVANCED MENU Reset to Defaults? EXIT NEXT RESET To exit the Reset to Defaults menu without resetting the charge controller: Press <EXIT> to return to the main menu. Press <EXIT> again to return to the status screen. This will exit the menu without making any changes to the current settings. To reset the FLEXmax to factory default settings: Are you Sure? Reset to Defaults YES NO ADVANCED MENU Reset to Defaults? EXIT NEXT RESET 1. Press <RESET>. 2. Press <YES> to confirm the reset. Upon the next power-up, the FLEXmax will prompt the user to confirm the voltage (see page 22.) 3. Press <EXIT> twice to return to the main menu. 4. Press <NEXT>to return to the beginning of the ADVANCED MENU (see page 52). This procedure is recommended any time the controller is relocated or the system is substantially revised. The settings can also be reset to the defaults by performing a reboot (see page 63). Figure 47 900-0009-01-00 Rev B Reset to Defaults? Screen 59 Operation Logging The Logging screen in the main menu enables the user to clear the daily and cumulative logs if necessary. Logs can be downloaded to an SD card if a MATE3 is installed. See page 75 for details. The FLEXmax daily log begins when the controller enters Wakeup. See page 30. IMPORTANT: If two or more charge controllers are used in the same system and are started up or cleared on different days, their numeric dates will not be the same. This can lead to some misunderstandings when looking back and comparing data between the two or more units. A user looking back at day 12 on both units would find very different results. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To clear the logs: 1. From the main menu, press <> to move the arrow next to Logging. 2. Press <GO> to advance to the End-of-the-Day summary screen. 3. Press the second soft key (SK2) to bring up the CLEAR Log screen. The CLEAR LOG screen offers the option of clearing up to 128 days of accumulated statistics or the total in the secondary STATS screen (page 62). 4. Press and hold either <TOTL> (total) or <DAILY> to clear those specific statistics. The Are you sure? screen appears. 5. Pressing <YES> returns to the CLEAR LOG screen; pressing <NO> returns to the Logging screen. 6. Press <BACK> to return to the End-of-Day summary screen. End-of-Day Summary Screen Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 CLEAR LOG BACK TOTL DAILY Pressing SK3 and SK4 changes the displayed day’s statistics, by moving either forward or backward within the 128 days of available statistics that are viewable. Are you Sure? NO Today 000Ah 00.0kWH 011Vp 00.0Ap 0.00kWp MAX 14.7 V ABS 01:00 MIN 14.6 V FLT 00:00 YES Figure 48 60 Logging Mode 900-0009-01-00 Rev B Operation Stats The STATS screen in the main menu displays additional voltage and time information. In a stand-alone FLEXmax controller — one that is not connected to a system display — Sunrise shows how long ago the FLEXmax woke up for the first time each day and when the daily and total logged values were updated and cleared. If the FLEXmax is connected to a system display, the logging occurs at midnight. Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To view the STATS screen: 1. From the main menu, press <> to move the arrow next to STATS. 2. Press <GO> to advance to the statistics screens. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO Max Bat Voc MaxVoc 14.9 036.6 133.0 MaxWatt 0000 Sunrise EXIT NEXT 01:30:33 Maximum historical battery voltage occurring on the FLEXmax Max Bat Voc MaxVoc 14.9 036.6 133.0 MaxWatt 0000 Sunrise EXIT NEXT 01:30:33 Daily high Voc value Max Bat Voc MaxVoc 14.9 036.6 133.0 MaxWatt 0000 Sunrise EXIT NEXT 01:30:33 The highest historical Voc occurring on the FLEXmax. Max Bat Voc MaxVoc 14.9 036.6 133.0 MaxWatt 0000 Sunrise EXIT NEXT 01:30:33 Maximum wattage seen by the FLEXmax Max Bat Voc MaxVoc 14.9 036.6 133.0 MaxWatt 0000 Sunrise EXIT NEXT 01:30:33 The time the logs were cleared and reset Max Bat Voc MaxVoc 14.9 036.6 133.0 MaxWatt 0000 Sunrise EXIT NEXT 01:30:33 Press <NEXT> to view the second STATS screen. Figure 49 900-0009-01-00 Rev B STATS Mode 61 Operation The Secondary Stats screen shows the total accumulated DC and AC kilowatt-hours and kiloamp-hours of the charge controller. Secondary STATS Screen Total Total BACK Total Total BACK 00000 0000.0 kWH kAH Pressing the <DCkWH> soft key switches the screen between DC kilowatt-hours and AC kilowatt-hours. DCkWH 00000 0000.0 kWHAC kAH DCkWH shows the DC kilowatt-hours and should be used in a system that is not grid-interactive. ACkWH is used with a grid-interactive system. This measure is based on a 90% inverter efficiency (1 kWh DC= 0.9 kWh AC). Pressing the <BACK> key three times returns to the main menu. ACkW Figure 50 Secondary STATS Screen Viewing the Firmware Revision The current firmware revision of the FLEXmax controller can be viewed on its own screen. Main Menu Status Screen In Out 113.6V 12.5V 0.000 kW AUX: OFF Return to the main menu screen. From the status screen, press the first soft key (SK1) to open the main menu screen. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 0.0 A 0.0 A 0.0 kWH Sleeping From the main menu screen, press and hold <EXIT> (SK1). As long as SK1 is held, it will show a Revision screen with the current firmware revision of the FLEXmax. Revision 002.001.000 Figure 51 Firmware Revision Screen Extended Play Mode If the MPP voltage is low enough to approach the battery voltage (usually when the PV array is very hot), it is near the effective limit of the MPPT function. Side effects may cause the FLEXmax components to make a squealing noise. Extended Play mode alleviates this problem by extending the parameters of the MPPT sweep. (See page 98 for additional notes.) To activate or deactivate the Extended Play feature: Revision Screen Follow the instructions in Figure 51 for reaching the Revision screen. While continuing to hold SK1, press and hold SK3. After a few seconds, the screen will toggle the status of Extended Play and display it. X on means the mode is on. If necessary, continue to press and hold SK3 until it reads X on. Revision X on 002.001.000 To deactivate this function, repeat the process until the screen reads X off. Figure 52 62 Extended Play Screen Extended Play Mode 900-0009-01-00 Rev B Operation Rebooting the FLEXmax If the screen becomes garbled or the FLEXmax controller otherwise will not respond to commands, it may be necessary to reboot its internal processor. IMPORTANT: Rebooting the FLEXmax controller will return all the values and set points to the factory defaults. These values are listed on page 100. It is advisable to record all custom values before rebooting. To reboot the FLEXmax: 1. Turn off the battery and PV array circuit breakers. The FLEXmax should have no sources of power connected. Observe the screen until it goes blank. DC Circuit Breakers 2. Press and hold the first and third soft keys (SK1 and SK3). 3. While holding down these soft keys, switch on the battery circuit breaker. This process follows the power-up sequence shown on page 21. Continue to follow the Select Version screen instructions from the beginning of the manual. SK1 and SK3 Figure 53 900-0009-01-00 Rev B Rebooting the FLEXmax 63 Operation NOTES: 64 900-0009-01-00 Rev B MATE3 System Display and Controller The MATE3 provides the means for programming the FLEXmax charge controller and other devices when preprogrammed default settings do not work for the destined installation. Display and LED Status Indicators Battery Status LEDs (x3) LCD Screen Inverter LED Events LED Charger LED AC Input LED Generator LED Favorite LED Figure 54 900-0009-01-00 Rev B Display and LED Status Indicators 65 MATE3 Screens Charge Controller Soft Key PV Icon Charge Controller Soft Key Press this soft key to view FLEXmax charge controller status information. If no charge controller is present, the PV icon will be blank and this soft key will be inoperative. Charge Controller’s Mode Charge Controller Modes: Bulk Absorb Float EQ Silent The FLEXmax has over 25 modes. The MATE3 can only display five status messages and may substitute one of the five for a FLEXmax mode not on this list. Check the FLEXmax status screen to determine its exact mode. See page 26 for a description of modes. See page 102 for a description of battery charging. The upper left corner of the screen shows the FLEXmax charge controller’s current mode of operation. Bulk is shown in this illustration. Soft Keys: In displays the present PV array operating voltage and the current being harvested from the array. <Datalog> brings up a group of charge controller statistics that are maintained as a continuous daily log. These screens are all shown beginning on page 67. <Graph> brings up a series of screens that plot various charge controller information over time. The graphs include inverter and charger wattage, power imported from an AC source, battery voltage, and others. These screens are all shown beginning on page 68. VOC displays the open-circuit voltage available from the PV. Out displays the present battery voltage and the current being delivered from the charge controller(s) to charge the battery bank. To the right, this line displays the number of kilowatt-hours and amp-hours accumulated that day. Operating displays the total hours the charger has operated that day in any stage. Float displays the run time of the Float timer when in the Float stage. <Port> cycles through each device connected to the network. If more than one charge controller is installed in the system, pressing the <Port> soft key will cycle through each controller. Absorb displays the run time of the timer when in the Absorbing stage. <Back> returns to the previous screen. The lower right corner shows the current status of the charge controller’s Auxiliary (AUX) output. (See page 72.) Figure 55 66 Screen Items: Maximum displays the maximum amperage and wattage harvested from the PV array that day, and the time both were recorded. Charge Controller Soft Key Screens 900-0009-01-00 Rev B MATE3 Screens DataLog Screen The <DataLog> soft key shows accumulated daily amp-hour and watt-hour statistics, as well as maximum current, wattage, and maximum and minimum voltage figures. These maintain a continuous daily log, up to 128 days, which can be recalled. One day can be displayed at a time. See page 61 for more information. Current Date Screen Items: The upper left corner shows the date of the selected Datalog screen. (The current Datalog screen reads "Today.") To the right, this line also displays the kilowatt-hours and amp-hours accumulated that day. Max Output displays the maximum current and wattage recorded that day. Soft Keys: Absorb The amount of time the Absorbing <+Day> advances the display forward by a single day. If the display reads “Today”, it does nothing. <–Day> advances the display backward by a single day and will display the selected date. <Back> returns to the previous screen. <Port> cycles through each device connected to the network. Figure 56 900-0009-01-00 Rev B timer ran that day. Float The amount of time the Float timer ran that day. High VOC displays the highest open-circuit voltage (VOC) recorded that day. Min Batt displays the lowest battery voltage recorded that day. Max Batt displays the highest battery voltage recorded that day. DataLog Screen 67 MATE3 Screens Graph Screens The <Graph> soft key brings up the following screens which plot various type of data over time. The first screen shows changes in PV wattage over time. This axis shows date and time in 6-hour increments. This axis shows PV wattage. Figure 57 Output Graph The <Next> soft key brings up a screen showing changes in battery voltage over time. This axis shows date and time in 6-hour increments. This axis shows battery voltage. Figure 58 Battery Graph The <Next> soft key brings up a screen showing changes in PV voltage over time. This axis shows date and time in 6-hour increments. This axis shows PV voltage. Figure 59 PV Graph Continuing to press the <Next> soft key will proceed through the same graphs again from the beginning. 68 900-0009-01-00 Rev B MATE3 Screens Menu Structure in the MATE3 Figure 60 shows the MATE3 menu structure for adjusting the FLEXmax charge controller settings. Figure 60 Menu Structure The Main Menu shown above is accessed with the LOCK button and a password. Use the MATE3’s control wheel to move up and down between menus (or options within a menu). Use the center button on the control wheel to make a selection. (See the MATE3 manual for more information.) Some menus may not be accessible if the user access levels are restricted. 900-0009-01-00 Rev B 69 MATE3 Screens Charge Controller Settings Charge Controller menu options include the following: Charger ------------------------------------------------------------- > MPPT ---------------------------------------------------------------- > Temperature Compensation ------------------------------- > Battery Equalize ------------------------------------------------ > Grid-Tie Mode --------------------------------------------------- > Auxiliary Output ------------------------------------------------ > Restart Mode ----------------------------------------------------- > Calibrate ----------------------------------------------------------- > Reset Charge Controller to Factory Defaults -------- > See page 70. See page 70. See page 71. See page 71. See page 71. See page 72. See page 73. See page 74. See page 74. Charger IMPORTANT: Battery charger settings need to be correct for a given battery type. Always follow battery manufacturer recommendations. Making incorrect settings, or leaving them at factory default settings, may cause the batteries to be undercharged or overcharged. The charge controller uses a “three-stage” battery charging cycle which utilizes multiple settings. This menu controls the voltages and timers for the battery charger. See page 102 for an explanation of the three-stage cycle and a description of the individual stages. Set Points: Absorb Voltage (Absorb) Time Float Voltage Rebulk Voltage Current Limit Absorb End Amps Figure 61 Charger MPPT The charge controller uses a maximum power point tracking (MPPT) algorithm which manipulates the output of the PV array to harvest maximum wattage. Although this function is automatic, this menu allows the user to adjust many of its parameters for special applications. See page 53, 54, and 106. Set Points: MPPT Mode U-Pick VOC Wakeup VOC Change VDC and Wakeup VOC Change Time – The FLEXmax screen refers to these items under the title “Wakeup Mode” Snooze Mode Amps MPP Range Minimum and MPP Range Maximum – The FLEXmax screen refers to these items under the title “Mpp Range Limit %” Figure 62 70 MPPT 900-0009-01-00 Rev B MATE3 Screens Temperature Compensation When equipped with the Remote Temperature Sensor (RTS), the charge controller compensates for temperature changes by raising or lowering its charging voltages. However, in some cases the sensitivity of other DC devices may require this temperature compensation to be limited. This menu allows the user to manually adjust the upper and lower limits of temperature compensation. See page 103 for an explanation of compensation. See page 56 for the FLEXmax RTS Compensation menu. Set Points: Mode Limited: Lower Battery Voltage Limited: Upper Battery Voltage The FLEXmax menu features these items as options under “RTS Compensation.” Figure 63 Temperature Compensation Battery Equalize CAUTION: Battery Damage Do not equalize any sealed battery types (VRLA, AGM, Gel, or other) unless approved by the manufacturer. Some batteries may suffer severe damage from equalization. Contact the battery manufacturer for recommendations on equalization voltage, duration, schedule, and/or advisability. Always follow manufacturer recommendations for equalization. This menu controls the settings for the equalization process, which is used for battery maintenance. See page 48 for an explanation of equalization and how it relates to the regular charging process. Set Points: Figure 64 Equalization Voltage (Equalization) Hours Automatic Battery Equalization Battery Equalize Grid-Tie Mode IMPORTANT: This mode requires a grid-interactive inverter model (also known as grid-tie enabled). Not all inverters are grid-interactive. If the system is connected to an inverter that is not grid-interactive, Grid-Tie mode will not function if selected. This menu allows the charge controller to work more effectively with any grid-interactive inverters present on the HUB. See pages 50, 54, and 108 for more information. Set Points: Two options are available in this menu; N and Y: ~ ~ Figure 65 900-0009-01-00 Rev B N (No) disables Grid-Tie Mode; Y (Yes) enables Grid-Tie Mode Grid-Tie Mode 71 MATE3 Screens Auxiliary Output (Charge Controller) This menu controls the output and functionality of the Auxiliary (AUX) output. The charge controller’s AUX terminals provide a 12 Vdc output that can deliver up to 0.2 Adc to control external loads. Typical loads include signaling a generator to start, sending a fault alarm signal, or running a fan to cool the inverter. See page 17 for an image of the AUX terminals. See page 33 for a description of AUX modes. Set Points: Status – The Auxiliary Output status is controlled by the <Off>, <Auto>, and <On> soft keys. Aux Mode –Selects one of nine options: Vent Fan, PV Trigger, Error Output, Night Light, Float, Diversion:Relay, Diversion:Solid St, Low Battery Disconnect, and Remote. Figure 66 Auxiliary Output Aux Modes for the Charge Controller Aux Modes include nine options with automatic criteria. The options appear in the following order when the wheel is drawn clockwise. The Vent Fan option appears first if the charge controller is set at factory default values; otherwise, it will tend to display the last option selected. (The options are described in greater detail beginning on page 35.) NOTE: The Remote option allows the MATE3 to use the AUX output for AGS (see page 47). AGS is intended for systems with a HUB, inverter, and FLEXmax. If the MATE3 connects only to a FLEXmax, AGS will only work with DC genset programming. The other AGS functions will not work properly. Vent Fan Set Points: Enable Voltage Figure 67 Vent Fan PV Trigger Set Points: Enable Voltage Hold Time Active: High or Low. Figure 68 PV Trigger Error Output Set Points: Figure 69 72 Low Battery Voltage Error Output 900-0009-01-00 Rev B MATE3 Screens Night Light Set Points : Active: High or Low. Threshold Hysteresis Time ON Time Figure 70 Night Light Float Set Points : None Figure 71 Float Diversion: Relay and Solid St Set Points (NOTE: All items function identically for both Diversion: Relay and Diversion: Solid St, except for Active: High or Low): Figure 72 Active: High or Low. (Not present in Diversion: Solid St) Relative Voltage Hysteresis Hold Delay Diversion:Relay and Diversion: Solid St Low Batt Disconnect Set Points: Disconnect Re-Connect Disconnect Delay Figure 73 Low Batt Disconnect Remote Set Points: None This mode can also be used for the MATE3’s AGS function. See pages 47 and 72 for important information on this function. Figure 74 Remote Restart Mode This item selects between continuous MPPT, or occasional MPPT restarts. (See pages 27 and 58.) Set Points: 0 – Continuous MPPT, 1 – Automatic re-sweep every 90 minutes in MPPT charging, 2 – Automatic re-sweep every 90 minutes in any mode. Figure 75 900-0009-01-00 Rev B Restart Mode 73 MATE3 Screens Calibrate The Calibrate menu allows adjustment of the charge controller’s battery voltmeter. If a particular controller’s readings do not match those of another device, or a hand-held meter, the calibration feature may improve consistency. Set Points: Battery Voltage – Calibrates the Vdc measurement made at the controller’s battery terminals Calibration Offset Figure 76 Calibrate NOTE: Calibration does not change the actual voltage of the charge controller, only the reading of that voltage. Also, measurements in places other than the charge controller’s terminals may differ regardless of calibration. For example, it is possible to get a different reading at the charge controller’s DC terminals than on the batteries. Connection problems, corrosion, and the effects of induction and resistance may all result in voltage differences. If this occurs, note that this is an issue with the system, not the charge controller. Calibration cannot correct for it. Reset Charge Controller to Factory Defaults This menu allows the user to erase all settings from the selected charge controller and start over with the values programmed at the factory. These values are listed on page 100. To access the Reset to Factory Defaults menu: 1. Access the main menu as shown in Figure 16. 2. Select the Settings menu. (This option may be highlighted by default.) 3. Select Charge Controller in the device Settings menu. 4. Select the Reset to Factory Defaults menu. 5. Use the soft keys to select No or Yes. If <No> is selected, the screen returns to the Charge Controller menu. No changes will be made to any settings. If <Yes> is selected, the inverter’s settings will immediately change to the original factory values. The screen will display the message Charge Controller Restored to Factory Defaults. A <Continue> soft key will appear. Pressing this key will return the screen to the Charge Controller menu. 6. After resetting the charge controller to factory default parameters: press the <Continue> soft key or the Up navigation key to return to the Charge Controller menu, or press the Top navigation key to return to the Settings menu. Figure 77 74 Press <Continue> to return to the Charge Controller Menu. Restoring the Charge Controller to Factory Default Settings 900-0009-01-00 Rev B MATE3 Screens Device Data Logs Users of the MATE3 can create Device Data Logs for the FLEXmax charge controller. The Data Logs can then be uploaded and saved to an SD card. Saving Data Logs for the FLEXmax Charge Controller To create a data log for the FLEXmax Charge Controller: 1. Access the Main Menu as shown in Figure 16. 2. Select the Device Data Logs menu. 3. Select FLEXmax Charge Controller menu. 4. Select Upload and Save Data Log on the FM Charge Controller Data Log menu. 5. Select one of the two options. Press <New> to give the new data log a unique name. Or Press <Save> to save the data log over the name that is highlighted on the list. 6. After saving the data log is complete, press <Continue> to return to the Upload and Save Data Log screen. To save a new data log over the name highlighted on the list: 1. Use the control wheel to scroll through the list. 2. When the name to be replaced is highlighted, press <Save>. 3. Wait for the message confirming that the profile has been saved to the SD card. 4. Press <Continue> to return to the Upload and Save Data Log menu. Returns to the Upload and Save Data Log screen. To create a new name for the data log (up to 8 characters maximum): 1. Use the control wheel to scroll through the available characters. 2. Use <> and <> to move to the next character location. 3. Press <Delete> to erase the character that is highlighted. 4. Press <Save> to save the new data log on the SD card. 4. Press <Continue> to return to the Upload and Save Data Log menu. Returns to the Upload and Save Data Log screen. Figure 78 900-0009-01-00 Rev B Uploading and Saving a Data Log for the FM Charge Controller 75 MATE3 Screens Data Log File Format Information generated by this function will be saved on the SD card in a generic .csv file format, which can be read by most spreadsheet programs. Data Logging example: NOTE: This header line is NOT included in the download. Date AH Kwh Max Amps Max Watts Absorb Time Float Time Min Battery V Max Battery V MAX VOC 6/13/11 0 0 1.2 29 0:00 0:00 24.1 29.1 122 6/12/11 38 0.9 5.5 143 0:00 0:00 24.1 29 122 6/11/11 32 0.8 5.6 144 0:00 0:00 24.1 28.7 120 6/10/11 9 0.2 3.5 89 0:00 0:00 24.1 28.9 120 6/09/11 31 0.7 6.8 173 0:00 0:00 24.1 28.8 119 Figure 79 76 Data Log Example for the Charge Controller 900-0009-01-00 Rev B MATE/MATE2 Screens Summary Screens If a FLEXnet DC is installed in the system, the following summary screens will be available. FLEXnet DC Summary Screen #1 FLEXnet DC Summary Screen #2 FLEXnet DC Summary Screen #3 FLEXnet DC Summary Screen #4 FX Inverter/Charger Summary Screen (If the FNDC is not installed, this will be the 1st Summary Screen.) FLEXmax Charge Controller Summary Screen Figure 80 900-0009-01-00 Rev B Summary Screens 77 MATE/MATE2 Screens Status Screens To view the status screens of a FLEXmax 60 or FLEXmax 80 using a MATE, follow the illustration below. Changes to FLEXmax settings can only be changed from the charge controller user interface; changes can not be done when viewing these screens on a MATE. MODE Screens MAIN-----------------1:35:04p Navigation for STATUS/CC/MODE SUM <STATUS> returns to the STATUS/CC/PAGE1 screen. <DOWN> moves to the next menu item in the diagram. <UP> moves to the previous menu item in the diagram. <TOP> returns to the first CC/MODE screen for the port shown. <PORT> directs the MATE to read the next device (port) on the HUB. STATUS SETUP ADV STATUS---------------choose device FX CC DC MAIN STATUS/CC/PAGE1 Charge Controller Modes MODE METER The MODE screens describe the current operating mode for the FLEXmax charger (see page 26) and AUX output (see page 33). SETPT PG2 STATUS/CC/MODE-----P00 charger mode: Silent DOWN STATUS PORT STATUS/CC/MODE-----P00 aux relay mode: Low Batt DOWN UP TOP PORT STATUS/CC/MODE-----P00 aux relay state: ON DOWN UP TOP PORT STATUS/CC/MODE-----P00 End of mode menu UP TOP STATUS The FLEXmax has over 25 modes. The MATE can only display five status messages and may substitute one of the five for a FLEXmax mode not on this list. Check the FLEXmax status screen to determine its exact mode. charger mode: Bulk Absorption Float Silent Equalization aux relay mode: vent fan pv trigger error output night light float diversion: relay diversion: solid st low batt(ery) disconnect remote aux relay state: This screen indicates if the AUX output is Figure 81 78 ON OFF MODE Screens 900-0009-01-00 Rev B MATE/MATE2 Screens METER Screens MAIN-----------------1:35:04p Navigation for STATUS/CC/METER SUM <STATUS> returns to the CC/PAGE1 screen. <DOWN> moves to the next menu item in the diagram. <UP> moves to the previous menu item in the diagram. <TOP> returns to the first CC/METER screen for the port shown. <PORT> directs the MATE to read the next device (port) on the HUB. STATUS SETUP ADV STATUS---------------choose device FX CC DC MAIN Charge Controller METER Screens STATUS/CC/PAGE1 MODE METER SETPT PG2 The METER screens display readings for power, current, and voltage handled by the FLEXmax. (See page 78 for more information on the mode messages displayed here.) mode/pv-in/bat-out: mode: Silent P00 in 11.2 vdc 0 adc out 14.4 vdc 0 adc DOWN STATUS PORT STATUS/CC/METER----P00 charger 0 w watts DOWN UP TOP PORT mode (charger ) ~ Bulk ~ Absorption ~ Float ~ Silent ~ Equalization in vdc (PV array voltage) adc (incoming PV current) out vdc (battery voltage) adc (outgoing current delivered to the battery) charger watts: Charger output to the battery (watts). charger kwhrs: Kilowatt-hours sent to the batteries today. charger amps dc: Charger current to the battery (Adc). battery voltage: Battery voltage (Vdc). panel voltage: PV array voltage (Vdc). STATUS/CC/METER----P00 charger 0.0 kwh kwhrs DOWN UP TOP PORT CC Firmware revision: The level of the last revision or programming upgrade to the FLEXmax. STATUS/CC/METER----P00 charger +000 Adc amps DC DOWN UP TOP PORT STATUS/CC/METER----P00 battery 13.7 Vdc voltage DOWN UP TOP PORT STATUS/CC/METER----P00 CC Firmware revision 002.001.000 DOWN UP TOP PORT STATUS/CC/METER----P00 charger 0 ah amp hour DOWN UP TOP PORT STATUS/CC/METER----P00 panel 33 Vdc voltage DOWN UP TOP PORT STATUS/CC/METER----P00 End of meter menu Figure 82 900-0009-01-00 Rev B UP TOP STATUS METER Screens 79 MATE/MATE2 Screens SETPT Screens Navigation for STATUS/CC/SETPT MAIN-----------------1:35:04p <STATUS> returns to the CC/PAGE1 screen. SUM <DOWN> moves to the next menu item in the diagram. <UP> moves to the previous menu item in the diagram. <TOP> returns to the first CC/SETPT screen for the port shown. <PORT> directs the MATE to read the next device (port) on the HUB. STATUS SETUP ADV STATUS---------------choose device FX CC DC MAIN STATUS/CC/PAGE1 MODE METER SETPT PG2 Charge Controller SETPT (set point) Screens STATUS/CC/SETPT----P00 absorb 14.4 Vdc The SETPT screens display the current settings for the FLEXmax battery charger, as described on page 32. DOWN STATUS Absorb Float PORT STATUS/CC/SETPT----P00 float 13.6 Vdc DOWN UP TOP PORT STATUS/CC/SETPT----P00 end of set point menu UP TOP STATUS Figure 83 80 SETPT Screens 900-0009-01-00 Rev B MATE/MATE2 Screens LOG Screens MAIN-----------------1:35:04p Navigation for STATUS/CC/LOGS SUM <STATUS> returns to the CC/PG2 screen. <DOWN> moves to the next menu item in the diagram. <UP> moves to the previous menu item in the diagram. <TOP> returns to the 1st CC/LOG1 screen for the port shown. <PORT> directs the MATE to read the next device (port) on the HUB. <DAY–> displays log information from one day earlier. Logs can be displayed from as far as 128 days in the past. <DAY+> displays log information from one day later. If the present day is displayed, then pressing this key will return the log to 128 days in the past. STATUS SETUP ADV STATUS---------------choose device FX CC DC MAIN STATUS/CC/PAGE1 MODE METER SETPT PG2 STATUS/CC/PAGE2------PG1 LOGS STAT MAIN STATUS/CC/LOG1-----P00 TODAY 0 AH 00.0 kWH 21Vp 00.0Ap 0.00kWp DOWN DAY- DAY+ PORT STATUS/CC/LOG2-----P00 TODAY battery max 14.5V min 14.4V DOWN DAY- DAY+ PORT STATUS/CC/LOG3-----P00 TODAY absorb float 00:00 00:00 DOWN DAY- DAY+ PORT Charge Controller Logs The LOG screens contain information collected from the FLEXmax on individual days. These logs include daily accumulated amp-hours and kilowatt-hours, and peak readings for power, current, and voltage. It also includes the timers for the FLEXmax battery charger. This data is the same as that shown on the FLEXmax End-of-Day Summary screen (see page 24.) Log 1 Today: AH (accumulated battery amp-hours) Kwh (accumulated battery kilowatt-hours) Vp (peak PV voltage) Ap (peak PV current) kWp (peak PV kilowatt-hours) Log 2 Today: STATUS/CC/METER----P00 end of cc logs display TOP STATUS max V (maximum battery voltage) min V (minimum battery voltage) Log 3 Today: Figure 84 900-0009-01-00 Rev B absorb timer float timer LOG Screens 81 MATE/MATE2 Screens STAT Screens MAIN-----------------1:35:04p SUM STATUS SETUP ADV STATUS---------------choose device FX CC DC <STATUS> returns to the CC/PAGE2 screen. <DOWN> moves to the next menu item in the diagram. <UP> moves to the previous menu item in the diagram. <TOP> returns to the CC/STAT/PAGE2 screen for the port shown, with the exception of the “end of the cc stats” menu. From the “end” menu, the <TOP> soft key returns to the 1st CC/STAT screen. <PORT> directs the MATE to read the next device (port) on the HUB. MAIN STATUS/CC/PAGE1 MODE METER Navigation for STATUS/CC/STAT SETPT PG2 Charge Controller Stats STATUS/CC/PAGE2------PG1 LOGS STAT MAIN STATUS/CC/STAT-----P00 maximum battery 15.1 Vdc DOWN UP PORT STATUS/CC/STAT-----P00 voc 21.0 vdc DOWN UP TOP PORT STATUS/CC/STAT-----P00 max voc 21.0 vdc DOWN UP TOP PORT STATUS/CC/STAT-----P00 maximum wattage 400 W DOWN UP TOP PORT Figure 85 82 The STAT screens contain historical data for the FLEXmax, including peak voltages, peak wattage, and total accumulations. (See page 61.) maximum battery Vdc: voc: max voc: maximum wattage: total kWH DC: total kAH: STATUS/CC/STAT-----P00 total kWH DC 307 DOWN UP TOP PORT STATUS/CC/STAT-----P00 total kAH 25.6 DOWN UP TOP PORT STATUS/CC/STAT----P00 end of cc stats menu UP TOP STATUS STATUS STAT Screens 900-0009-01-00 Rev B MATE/MATE2 Screens Advanced Menus The Advanced menus available in the MATE or MATE2 system display allow the following options: Change the settings of the FLEXmax battery charger and temperature compensation Change the parameters of the FLEXmax MPPT process Change the settings of the FLEXmax equalization process Calibrate the FLEXmax meters Change the settings of the Auxiliary output to run small AC or DC loads Start a generator using Advanced Generator Start (AGS) Mode (see page 47) Adjust the settings or functions of other OutBack devices which are connected to the system display (see appropriate manuals) The following pages detail the MATE, or MATE2, Control Modes. Please note whenever a password is called for, the system password is: 141 Accessing the Advanced Menus MAIN-----------------1:35:04p SUM STATUS SETUP ADV ADV/SETTINGS/WARNING changes made could adversely affect system performance ADV/PASSWORD---------Enter the password 132 ENTER INC DEC EXIT ADV/PASSWORD---------Enter the password 141 ENTER INC DEC EXIT Figure 86 900-0009-01-00 Rev B Press any soft key to advance to the next screen. Press the <INC> soft key until 132 becomes 141. Press <ENTER> when the number 141 is displayed. This will proceed into the ADV choose device menu in the Advanced menu map. Press <EXIT> to return to the main menu without changing the password. Accessing the Advanced Menus 83 MATE/MATE2 Screens CHGR Menu Navigation for ADV/CC/CHGR <DOWN> moves to the next menu item in the diagram. <INC> increases the value of the selection. <DEC> decreases the value of the selection. <PORT> directs the MATE to read the next device (port) on the HUB. <ADV> returns to the CC/PAGE1 screen. <TOP> returns to the CC/CHGR screen. <MAIN> exits the Advanced menus and returns to the main menu (see page 83). CC/Charger The CHGR screens adjust the same settings that are available on the Charger screen in the FLEXmax (see page 32). Figure 87 84 output current limit absorb voltage float voltage ADV Menu for Charging Features 900-0009-01-00 Rev B MATE/MATE2 Screens CC ADVANCED Menu CC/Advanced The ADVANCED screens adjust the same settings that are available on the Advanced screen in the FLEXmax (see page 52). These settings relate to charging, MPPT, temperature compensation, and calibration. Navigation for ADV/CC/ADVANCED Figure 88 900-0009-01-00 Rev B <DOWN> moves to the next menu item in the diagram. <INC> increases the value of the selection. <DEC> decreases the value of the selection. <PORT> directs the MATE to the next device (port) on the HUB. <TOP> returns to the CC/ADVANCED screen. <ADV> returns to the CC/PAGE1 screen. <MAIN> exits the Advanced menus and returns to the main menu (see page 83). ADV Menu for the Advanced Charging Features 85 MATE/MATE2 Screens EQ Menu Navigation for ADV/CC/EQ <DOWN> moves to the next menu item in the diagram. <INC> increases the value of the selection. <DEC> decreases the value of the selection. <PORT> directs the MATE to read the next device (port) on the HUB. <TOP> returns to the CC/EQ screen. <ADV> returns to the choose device screen. <MAIN> exits the Advanced menus and returns to the main menu (see page 83). CC/Equalization The EQ screens adjust the same settings that are available on the EQ screen in the FLEXmax (see page 48). Figure 89 86 eq voltage eq time eq auto eq interval ADV Menu for EQ Charging Features 900-0009-01-00 Rev B MATE/MATE2 Screens AUX Menu Navigation for ADV/CC/AUX <DOWN> moves to the next menu item in the diagram. <INC> increases the value of the selection. <DEC> decreases the value of the selection. <PORT> directs the MATE to read the next device (port) on the HUB. <TOP> returns to the CC/PAGE2 screen. <ADV> returns to the choose device screen. <MAIN> exits the Advanced menus and returns to the main menu (see page 83). CC/AUX The AUX screens adjust the same settings that are available on the Aux screen in the FLEXmax (see page 33). AUX mode: vent fan pv trigger error output night light float diversion: relay diversion: solid st low batt(ery) disconnect remote The remote mode also can be used for the MATE’s AGS function. See page 47. NOTE: The AGS function is only intended for use in systems with a HUB, inverter, and FLEXmax. If the MATE connects only to a FLEXmax, the only AGS function that will work is the DC genset programming. The other AGS functions will not work properly. NOTE: The MATE must have firmware revision 4.1.6 or higher for AGS to work. aux control Figure 90 900-0009-01-00 Rev B ON OFF ADV Menu for the AUX Features 87 MATE/MATE2 Screens MATE and MATE2 Menu Maps for the FLEXmax STATUS Menu Map Navigation for STATUS/CC/PAGE1 <DOWN> moves to the next menu item in the diagram. <UP> returns to the previous menu item in the diagram. <PORT> directs the MATE to read the next device (port) on the HUB. <TOP> returns to the STATUS/CC/PAGE1 screen. <STATUS> returns to the screen at the top of the respective column. Figure 91 88 MATE STATUS Menu Map (Page 1) 900-0009-01-00 Rev B MATE/MATE2 Screens Navigation for STATUS/CC/PAGE2 <DOWN> moves to the next menu item in the diagram. <UP> returns to the previous menu item in the diagram. <PORT> directs the MATE to read the next device (port) on the HUB. <TOP> returns to the STATUS/CC/PAGE2 screen. <STATUS> returns to the screen at the top of the respective column. Figure 92 900-0009-01-00 Rev B MATE STATUS Menu Map (Page 2) 89 MATE/MATE2 Screens Advanced Menu Map Navigation for ADV/CC/PAGE1 <DOWN> moves to the next menu item in the diagram. <UP> returns to the previous menu item in the diagram. <PORT> directs the MATE to read the next device (port) on the HUB. <TOP> returns to the CC/PAGE1 screen. <ADV> returnsto the choose device screen. Figure 93 90 MATE ADVanced Menu Map (Page 1) 900-0009-01-00 Rev B MATE/MATE2 Screens Navigation for ADV/CC/PAGE2 <DOWN> moves to the next menu item in the diagram. <UP> returns to the previous menu item in the diagram. <PORT> directs the MATE to read the next device (port) on the HUB. <TOP> returns to the CC/PAGE2 screen. <ADV> returns to the choose device screen. Figure 94 900-0009-01-00 Rev B MATE ADVanced Menu Map (Page 2) 91 MATE/MATE2 Screens This page intentionally left blank. 92 900-0009-01-00 Rev B Menu Maps for the FLEXmax Figure 95 900-0009-01-00 Rev B FLEXmax Startup Screens 93 FLEXmax Menu Maps Figure 96 94 FLEXmax Menu Map (Page 1) 900-0009-01-00 Rev B FLEXmax Menu Maps Figure 97 900-0009-01-00 Rev B FLEXmax Menu Map (Page 2) 95 FLEXmax Menu Maps Figure 98 96 FLEXmax Menu Map (Page 3) 900-0009-01-00 Rev B Troubleshooting IMPORTANT: Be sure to check out the OutBack customer and user forum at www.outbackpower.com/forum/ for more FLEXmax information. Symptom FLEXmax does not boot/power-up (blank LCD) Remedy Check the battery connection and polarity. Reverse polarity or an improper connection will cause power-up issues. Check the battery disconnect or circuit breaker. Ensure all circuit breakers are sized appropriately. Check the battery voltage at the FLEXmax terminals. A battery voltage below 10.5 Vdc may not power up the FLEXmax. A poor connection may not allow sufficient voltage to reach the FLEXmax. FLEXmax not producing expected power Check PV conditions. Clouds, partial shading, or dirty panels can cause poor performance. Check settings. The lower current limit set point in the Charger menu will yield a loss of power or poor performance symptoms. If the FLEXmax is in U-Pick mode, it may not track at the maximum power point. Check battery conditions and charging stage. If the batteries are charged (if the FLEXmax is in the Absorbing or Float stage), the FLEXmax will produce only enough power to regulate the voltage at the Absorbing or Float set point voltage. Less power is required during these stages. Determine the specified short-circuit current of the PV array. The MPP current is related to this number. Use a multimeter to determine if the short-circuit current is in the expected range. Array or wiring problems may restrict the available power. Check the PV array temperature. At high temperatures, the maximum power point voltage may be near or or lower than the battery voltage. FLEXmax not equalizing Make certain the equalization cycle has been started. ~ In the EQ menu, press START to begin the process. When the equalization cycle has been initiated, MPPT EQ will be displayed. The equalization cycle has been initiated, but the battery is not equalizing. 900-0009-01-00 Rev B ~ The cycle will begin when the target EQ set point voltage has been reached. A small array or cloudy weather will delay the EQ cycle. Running too many battery loads will also delay the cycle. ~ Check the PV array temperature. At high temperatures, the maximum power point voltage may be near or lower than the battery voltage. This can delay the cycle. 97 Troubleshooting Symptom FLEXmax is always SLEEPING Remedy Check battery voltage. If the battery voltage is at or above the Absorbing voltage set point (compensated for battery temperature), the FLEXmax will not wake up. Check PV voltage. The PV voltage has to be at least two volts greater than the battery voltage for the initial wakeup. If voltage is not present, check the PV array breaker (or fuse). Confirm the PV array breaker (or fuse) is sized appropriately. PV voltage reads 000 If the PV array voltage on the display rises with the PV breaker OFF, but reads 000 with the PV circuit breaker on, the PV array polarity may be reversed or shorted. If the PV voltage still reads 000 with the PV circuit breaker off after a minute, call OutBack Technical Support for assistance. Status screen shows BatTmpErr Confirm the type of temperature sensor. Only the OutBack RTS (remote temperature sensor) can be used with the FLEXmax. If the RTS is correct, it may be faulty or damaged. Disconnect the RTS from the jack to resume normal operation. Replace the RTS as soon as possible. FLEXmax internal fan not running The internal fan will only run when the internal temperature has reached approximately 112°F. The fan will continue running until the internal temperature is less than 104°F. FLEXmax makes a squealing sound If the MPP voltage is low enough to approach the battery voltage (usually when the array is very hot), it is near the effective limit of the MPPT function. This may cause the FLEXmax components to make a squealing noise. The problem can be alleviated by placing the FLEXmax in Extended Play, which extends the parameters of the MPPT sweep. See page 62 for instructions on using Extended Play. This mode may not be desirable under more standard conditions when the PV voltage is higher. The efficiency of the FLEXmax controller may be reduced. LCD display scrambled Reboot the FLEXmax controller as described on page 63. This will clear any operating problems or glitches. It will also restore all programming items to their factory default settings. 98 900-0009-01-00 Rev B Specifications Electrical and Mechanical Specifications Specification FLEXmax 60 FLEXmax 80 Output Current Rating @ 40°C ambient 60 amps continuous 80 amps continuous Nominal Battery System Voltage 12, 24, 36, 48 or 60 Vdc (adjustable) PV open circuit voltage 150 Vdc maximum (ETL Rating for UL1741 Standard); 145 Vdc temperature corrected Voc (operational maximum) Standby power consumption Less than 1 watt typical Charge cycle Three-stage Voltage regulation set points 13-80 Vdc Temperature compensation 5 mV per °C per 2 V cell (with optional RTS) PV input capability Down convert from any acceptable array voltage to any battery voltage. Examples: 72 Vdc array to 24 Vdc battery; 60 Vdc array to 48 Vdc battery Digital Display 4-line, 20-character per line backlit LCD display Remote Interface RJ45 modular connector Cat 5 cable 8 wire Operating Temperature Range* -40° to 60°C (automaticaly derated above 40°C) Conduit knockouts One 1” on the back; one 1” on the left side; two 1” on the bottom Warranty Five years parts and labor Dimensions 13.5” H x 5.75” W x 4” D 16.25” H x 5.75” W x 4”D Shipping Dimensions 18” H x 11” W x 8” D 21” H x 10.5” W x 9.75”D Weight 11.6 lb (14 lb boxed) 12.20 lb (15.75 lb boxed) Options RTS, HUB 4, HUB 10, MATE, MATE2, MATE3 Menu Languages English and Spanish Firmware Revision This manual applies to FLEXmax 80 or FLEXmax 60 charge controllers with a firmware revision of 002.001.xxx or higher. Regulatory Specifications Table 4 Regulatory Specifications for All Models UL 1741 1st Edition; 2005 Version, CSA 107.1-01 CE Conformance European EN 55022 Class B 900-0009-01-00 Rev B 99 Specifications Default Settings and Ranges Table 5 Mode Menu Item Setting Current Limit (FLEXmax 80) Default 80 Adc Range: 5 to 80 Adc Current Limit (FLEXmax 60) Default 60 Adc Range: 5 to 60 Adc Charger Absorbing Float Vent Fan Volts PV Trigger Hold Time Sec PV VOLTS ERROR OUTPUT ERROR LOW BAT VOLTS Night Light ON Hysteresis Time (Minutes) On Time (Hours) Threshold Voltage Aux Float Diversion:Relay Hold Time (Seconds) Delay Time (Seconds) Absorb-Float-EQ Relative Volts HYST Diversion:Solid St Hold Time (Seconds) Delay Time (Seconds) Absorb-Float-EQ Relative Volts HYST 100 FLEXmax Settings Default 14.4 Vdc Range: Float setting to 80 Vdc Default 13.8 Vdc Range: 12.0 Vdc to Absorbing setting Default <Off> <On, Auto, Off> Default 14.4 Vdc Range: 10. 0 to 80.0 Vdc Default <Off> <On, Auto, Off> Default 01.1 second Range: 0 to 25 seconds Default 140 Vdc Range: 20 to150 Vdc Default <Off> <On, Auto, Off> Default 11.5 Vdc Range: 10 to 80 Vdc Mode Menu Item Setting Low Battery Disconnect Aux (cont’d) Delay Time Sec DISCONNECT VOLTS RECONNECT VOLTS Default <Off> <On, Auto, Off> Remote Default <AUTO> <ON, AUTO, OFF> Default 2 minutes Range: 1 to 9 minutes Default 14.4 Vdc Range: Absorbing setting to 80 Vdc Default 01 hours Range: 1 to 7 hours Default 000 days Range: 000 to 250 days Default 0.6 Adc Range: 0.2 to 1.0 Adc Default 1.5 Vdc Range: 1.5 to 9.5 Vdc Default 05 minutes Range: 05 to 15 min. MODE Light Auto Time BATTERY EQUALIZE Volts EQ BATTERY EQUALIZE Time EQ INTERVAL Snooze Mode Wakeup Mode Volts Default <Off> <On, Auto, Off> Default 001 minute Range: 001 to 255 min. Default 04 hours Range: 00 to 23 hours Default 010 Vdc Range: 005 to 150 Vdc Wakeup Mode Time Default <Auto Track > <Auto Track or U-Pick> Default 77% Voc Range: 40 to 90% Voc MPPT Mode Park Mpp Default <Off> <On, Auto, Off> MPP Range Limit (Max) Default <Off> <On, Auto, Off> Default 0.1 second Range: 0.0 to 25 sec. Default 0.0 seconds Range: 0.0 to 24 sec. Default 0.0 Vdc Range: 0.0 to 5.0 Vdc Default 00.2 Vdc Range: 0.0 to12.0 Vdc MPP Range Limit (Min) Default <Off> <On, Auto, Off> Default 0.1 second Range: 0.0 to 25 sec. Default 00 seconds Range: 00 to 24 sec. Default 0.0 Vdc Range: 0.0 to 5.0 Vdc Default 00.2 Vdc Range: 0.0 to12.0 Vdc Absorb Time Limits Advanced Absorb End Amps Rebulk Voltage Vbatt Calibration RTS Compensation Upper Limit RTS Compensation Lower Limit Default <Off> <On, Auto, Off> Default 01 second Range: 000 to 250 sec. Default 13.6 Vdc Range: 10 to 80 sec. Default14.4 Vdc Range: 10 to 80 sec. Default <90%> <80, 85, 90, 99%> Default <1/2> <1/2 or FULL> Default 01.0 hours Range: 00.0 to 24 hours Default 00 Adc Range: 00 to 55 Adc Default 12.0 Vdc Range: 12.0 Vdc to Float setting Default 0.0 Vdc Range: -0.5 to 0.5 Vdc Default 14.1 Vdc Range: Lower Limit setting to 80 Vdc Default 14.1 Vdc Range: 10 Vdc to Upper Limit setting Auto ReStart Default <0> Selections <0, 1 , 2> Aux Polarity Default <Active High> <Active High or Low> 900-0009-01-00 Rev B Applications Maximum Power Point Tracking Maximum Power Point Tracking (MPPT) is the technology used by FLEXmax controllers to optimize the harvest of power from PV arrays. PV modules do not have a defined operating voltage. Their voltage is defined strictly by the load connected to them. With no load (disconnected), a module displays “open-circuit” voltage (Voc), and delivers no current. At full load (shorted), a module has no voltage, although it delivers the maximum “short-circuit” current (Isc). In neither case does it produce usable wattage. When partially loaded, a PV module delivers partial current and voltage. These numbers can be multiplied to see the available wattage. However, the delivery of wattage is not linear. The current and voltage delivered at a given load will change with the load, along a curve such as that shown in the drawing to the left in Figure 99. This is known as the V-I curve. The wattage is different at every point along the curve. (The V-I curve also varies with module type and manufacturer.) Only one point on the V-I curve represents the delivery of the module’s maximum (rated) wattage. This is known as the maximum power point , or MPP. The current at this point, Imp, is the highest that can be drawn while still maintaining the highest voltage, Vmp. The FLEXmax controller places a variable load on the PV array and tracks the result to determine the maximum power point. This process, MPPT, is maintained so that the FLEXmax can deliver the maximum PV power regardless of any change in conditions. The drawing to the right in Figure 99 shows the MPP and compares the V-I curve against the available wattage. Isc Isc MPP CURRENT CURRENT Imp VOLTAGE Voc V-I curve Vmp Voc Available wattage Figure 99 900-0009-01-00 Rev B VOLTAGE Maximum Power Point Tracking 101 Applications Three-Stage Battery Charging The FLEXmax charge controller is a sophisticated, multi-stage battery charger that uses several regulation stages to allow fast recharging of the battery system while ensuring a long battery life. This process can be used with both sealed and non-sealed batteries. The FLEXmax is a “buck” converter which turns higher PV voltages into the lower charging voltages used by batteries (with correspondingly higher currents). The chart in Figure 100 shows the voltage levels achieved by the PV array throughout a typical day, and the battery voltages (by stage) during the same times. Input Votlage (24 Vdc system example) The FLEXmax has preset recharging voltage set points (Absorbing and Float voltages); however, OutBack always recommends using the battery manufacturer’s recommended charging voltages. Time Figure 100 FLEXmax 80 Three-stage Battery Charging A new charge cycle is started any time the battery voltage decreases below the Rebulk set point . (See page 56.) This usually occurs each night unless the batteries were maintained by another means. (If so, they may not need to be recharged). See pages 26 through 30 for the messages displayed onscreen during the various stages. BULK This is the first stage in the three-stage charge cycle. It is a constant-current stage which drives the battery voltage up. The DC current is the maximum current the charger can deliver. This stage typically leaves the batteries at 75% to 90% of their capacity, depending on conditions. In the Bulk stage, the FLEXmax will charge the batteries to the Absorbing voltage setting (see page 32). This stage is not timed. It will charge as long as necessary to complete the stage, regardless of any timer set points. If little PV energy is available, it may take a long time for this stage to complete. If the FLEXmax is in a different charging stage and little PV energy is available, it may return to Bulk. (See page 26.) This stage is temperature-compensated. (See page 103.) 102 900-0009-01-00 Rev B Applications ABSORBING This is the second stage of charging. It is a constant-voltage stage. Current varies as needed to maintain the Absorbing voltage setting. However, it will typically decrease to a very low number over time. This “tops off the tank”, leaving the batteries at essentially 100% of capacity. The duration of the Absorbing stage is the user-defined Absorb Time Limit. The ChgT timer is preset to zero following the previous charge cycle. Once in Absorbing, ChgT will count until it reaches this limit. (See pages 26, 50, and 54.) The charger will then exit Absorbing and enter the Float stage. The charger will also also exit Absorbing if the Absorb End Amps setting is reached, regardless of the timer. This resets the timer to zero. (See page 50.) This stage is temperature compensated. (See page 103.) FLOAT When the charger enters this stage, it reduces the charging voltage to prevent overcharging of the batteries. The batteries are maintained at the Float set point. Floating is displayed on the screen. This stage is not timed. The FLEXmax will continue to maintain Float as long as PV energy is available. If the PV cannot supply enough power to maintain the Float set point, the FLEXmax will not immediately initiate a new charge cycle. It will attempt to draw more PV energy and recharge the battery until the Float voltage set point is reached. When this occurs, MPPT Float is displayed (see page 28). This stage is temperature compensated. (See page 103.) A new charge cycle can be initiated if the voltage falls below the ReBulk set point (see page 56). Battery Temperature Compensation Battery performance changes when the temperature varies above or below room temperature (77°F or 25°C). Temperature compensation is a process that adjusts charging to correct for these changes. When a battery is cooler than room temperature, its internal resistance goes up and the voltage changes more quickly. This makes it easier for the charger to reach its voltage set points. However, while accomplishing this process, it will not deliver all the current that the battery requires. As a result, the battery will tend to be undercharged. Conversely, when a battery is warmer than room temperature, its internal resistance goes down and the voltage changes more slowly. This makes it harder for the charger to reach its voltage set points. It will continue to deliver energy as time passes until the charging set points are reached. However, this tends to be far more than the battery requires, meaning it will tend to be overcharged. The FLEXmax controller, when equipped with the Remote Temperature Sensor (RTS) will compensate for temperature. The RTS is attached to a single battery near the center of the bank. When charging, the RTS will increase or decrease the charge voltage by 5 mV per degree Celsius per battery cell. This setting affects the Absorbing and Float set points. Equalization is not compensated in the FLEXmax. In a 12 Vdc system (6 cells, 2 volts each), this means 0.03 volts per degree Celsius above or below 25°C. Maximum compensation is ± 0.6 Vdc. In a 24 Vdc system (12 cells, 2 volts each), this means 0.06 volts per degree Celsius above or below 25°C. Maximum compensation is ± 1.2 Vdc. In a 48 Vdc system (24 cells, 2 volts each), this means 0.12 volts per degree Celsius above or below 25°C. Maximum compensation is ± 2.4 Vdc. Examples: A 12 Vdc system with 10°C batteries will compensate its charging to 0.45 Vdc higher than the set points. A 24 Vdc system with 35°C batteries will compensate its charging to 0.6 Vdc lower than the set points. A 48 Vdc system with 15°C batteries will compensate its charging to 1.2 Vdc higher than the set points. 900-0009-01-00 Rev B 103 Applications Array Design Sizing Guidelines Below is a list of maximum array wattages for the FLEXmax for various nominal voltage batteries. This should be used for sizing an array. Note that every PV module is different. The specifications for every model should be consulted before designing or assembling a PV array. Table 6 Maximum PV Input Wattage per Charge Controller1 Nominal Battery Voltage Maximum Array Size (in watts, Standard Test Conditions) FLEXmax 80 FLEXmax 60 12 V 1250 W 800 W 24 V 2500 W 1600 W 36 V 3750 W 2400 W 48 V 5000 W 3200 W 60 V 6250 W 4000 W Open Circuit Voltage (Voc) Open-circuit voltage (Voc) is the unloaded voltage generated by the PV array. The FLEXmax controller can withstand Voc of up to150 Vdc. However, if the Voc exceeds 145 Vdc, the FLEXmax will suspend operation to protect the system components. CAUTION: Equipment Damage Although the FLEXmax shuts down when voltage is greater than 145 Vdc, this will not prevent the array from generating voltage. Anything higher than 150 Vdc will damage the FLEXmax, whether it has shut down or not. The array should be designed so that voltage never exceeds 145 Vdc in order to prevent equipment damage. Weather Conditions Cooler climates can cause the Voc to rise above the array’s rated Voc. In climates that observe temperatures less than approximately -15°C (5°F), a Voc greater than 125 Vdc is not recommended. Hot weather: lower Voc and lower Vmp Cold weather: higher Voc and higher Vmp If the specific voltage temperature correction factor is not known for a particular module, allow for ambient temperature correction using the following information: 1 25° to 10°C (77° to 50°F) multiply Voc by 1.06 9° to 0°C (49° to 32°F) multiply Voc by 1.10 -1° to -10°C (31° to 14°F) multiply Voc by 1.13 -11° to -20°C (13° to -4°F) multiply Voc by 1.17 -21° to -40°C (-5° to -40°F) multiply Voc by 1.25 Based on the most common solar arrays under Standard Test Conditions (1000 watts per square meter to solar panel at 25°C [77°F] ). 104 900-0009-01-00 Rev B Applications Maximum-Power Voltage (Vmp) Maximum-power voltage (Vmp) is the operating voltage for the PV array at which the array generates the most wattage. When designing the PV array, it is recommended for the Vmp to be approximately 12 to 24 volts higher than the nominal battery voltage for optimum performance. This will ensure that the Vmp is always above the battery voltage, which is required for charging. Higher voltages are not recommended, as they may reduce the FLEXmax conversion efficiency. IMPORTANT: Check the PV array voltage before connecting it to the FLEXmax. Standard vs. Australian Default Settings Several version settings are available for the FLEXmax upon initial setup. These can be selected upon initial power-up. (See page 21.) The English and Spanish versions have the same standard default settings; however, the Australian version has certain default settings that are different. However, there are no differences in performance and efficiency between the two versions. The standard and Australian version can be identified as follows: Standard Power Up Screen OutBack Australian Power Up Screen 12V OutBack 12V Power Power Systems Charge Controller Systems Charge Controller - AU Figure 101 Table 7 Standard vs. Australian Power-up Screens Default Settings Standard vs. Australian Settings Standard Australian Charger Absorbing Float Absorbing Float 12 V 14.4 V 13.6 V 14.4 V 13.8 V 24 V 28.8 V 27.2 V 28.8 V 27.6 V 36 V 43.2 V 40.8 V 43.2 V 41.4 V 48 V 57.6 V 54.4 V 57.6 V 55.2 V 60 V 72.0 V 68.0 V 72.0 V 69.0 V Equalize Equalize Volts Equalize Volts 12 V 14.4 V 14.7 V 24 V 28.8 V 29.4 V 36 V 43.2 V 44.1 V 48 V 57.6 V 58.8 V 60 V 72.0 V 73.5 V Equalize Time 01 Hours 03 Hours 900-0009-01-00 Rev B 105 Applications Hydroelectric and Fuel Cell Applications Performance Optimization The FLEXmax Charge Controller is designed to work with PV arrays. Although it will work with hydroelectric turbines and fuel cells, OutBack Power Technologies can only offer limited technical support for these applications due to variance in turbine and fuel cell specifications. IMPORTANT: The FLEXmax Charge Controller is not usable for direct regulation of wind turbine input and OutBack cannot warranty its use in these applications. In wind turbine applications, the FLEXmax is recommended as a diversion controller. (See page 41.) The FLEXmax maximum power point tracking (MPPT) function can be set to Auto Track or U-Pick% mode as described on page 54. The MPPT function is based on the open-circuit voltage (Voc) of the DC source. This is the unloaded voltage displayed by the source when it is disconnected. MPPT values are expressed as a percentage of Voc. Auto Track mode allows the FLEXmax to sweep the range of percentages. The Auto Track mode begins at the maximum value and loads the array, working its way through lower voltages, until it locates the input voltage that yields maximum wattage. Auto Track Mode The default minimum value of Auto Track is 1/2 (50% of Voc). The default maximum is 90% of Voc. This is the standard maximum-power range for PV. A hydroelectric or fuel-cell system’s operating voltage may operate in a different range and often have a maximum-power voltage close to the battery voltage. The FLEXmax allows a user to set a sweep range more appropriate for the source. The minimum setting can be changed to FULL, which is 40% of the Voc. The maximum value can be set from 80% to 99% of Voc if necessary. This adjustment only affects the initial tracking at the beginning of the day and any subsequent trackings caused by Auto-Restart or any forced restart of the FLEXmax. U-Pick Mode If an optimal voltage is known for a given DC source, then this voltage can be set as a designated Voc percentage in U-Pick% mode. This percentage is assigned in the Park Mpp set point, which allows a range of 40% to 99% of Voc. If U-Pick % Voc is chosen, the FLEXmax will load the source to operate continuously at the designated voltage. It will not sweep for the maximum power point and will ignore all Auto Track values. 106 900-0009-01-00 Rev B Applications Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO To adjust the Lower Mpp Range Limit: 1. From the main menu, press <> to move the arrow next to the Advanced function. Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO 2. Press <GO>. ADVANCED MENU Snooze Mode < 0.6 amp EXIT NEXT AMP 3. In the ADVANCED MENU screen, press <NEXT> again to display the Mpp Range Limit % Voc screen. 4. Press <1/2> until FULL appears. 5. When finished, press <NEXT> until the MPPT Mode screen appears. ADV SETUP Screen Mpp Range Limit % Voc ADVANCED MENU Mpp Range Limit %VOC Min Max EXIT NEXT 1/2 90% MPPT Mode (Auto Track) ADVANCED MENU MPPT Mode Auto Track EXIT NEXT nonGT MODE To pick between Auto Track or U-Pick % MPPT Mode and determine the charge controller’s operating Voc percentage, press <MODE> to interchange between the two modes. Re-entering the password might be required. After choosing a mode, press <NEXT> in the ADVANCED MENU to view the Park Mpp screen (only applicable for U-Pick mode). U-pick% (Voc) MPPT ADVANCED MENU Park Mpp Watts 0251 77 % Voc EXIT NEXT -% +% Figure 102 900-0009-01-00 Rev B Press < -%> or <+%> to select one of the percentage values; U-Pick always uses the Park Mpp value. Adjusting Range Limits for Hydroelectric or Fuel-cell Applications 107 Applications Grid-Interactive Settings When using an OutBack inverter, FLEXmax, HUB, and system display, set the FLEXmax to GT in the Advanced menu. GT mode allows the inverter to manage the FLEXmax Float setting. It ensures the FLEXmax always keeps the battery above the sell voltage of the inverter. (See page 54.) When using a FLEXmax charge controller with an inverter without the use of a HUB, GT mode will not work because the FLEXmax cannot communicate with the inverter. In this situation, when selling electricity back to the grid, keep the inverter’s “sell” voltage setting below the FLEXmax Float setting. In a 24-volt battery system, the difference should be at least 0.5 Vdc. In a 48-volt system, the difference should be at least 1.0 Vdc. Charge Controller Efficiency vs. Input Power Figure 103 108 Efficiency Curves 900-0009-01-00 Rev B Product Registration The purchase of an OutBack Power Technologies product is an important investment. Registering the products will help us maintain the standard of excellence expected in terms of performance, quality and reliability. Please take a moment to register and provide us with some important information. Registration can be done as follows: Go to the following website. 10Hhttp://www.outbackpower.com/resources/warranty/ or Fill out the information on this form (pages113 and 114) and return a paper copy using a postal service to the following address: OutBack Power Technologies Attn: Warranty Registration 5917 – 195th Street N.E., #7 Arlington, WA 98223 USA Be sure to keep a copy for your records. SYSTEM OWNER Name Address City, State, Postal Code or Zip Code Country Telephone Number E-mail SYSTEM PURCHASE Product Model Number Product Serial Number Sold by Purchase Date 900-0009-01-00 Rev B 109 Product Registration INSTALLATION INFORMATION System Install/Commission Date System Array Size System Array Nominal Voltage Type of PV Modules System Battery Bank Size (Amp-Hours) Brand and Model of Batteries Does this system include an auxiliary AC generator? If yes, please specify brand and model of generator INSTALLER INFORMATION Contractor Number Installer Name Installer Address Installer City, State, Postal or Zip Code, Country Installer Telephone/E-mail Please check ALL factors affecting purchase decision: Product Reputation Back-up Capability Reputation of OutBack Power Technologies Value Looks Other Extended Warranty OutBack Power Technologies offers an optional five (5) year extension to the standard five (5) year Limited Warranty for the FLEXmax Charge Controller. To request a 5-year limited warranty extension for a total effective warranty coverage period of ten (10) years, please include a payment in the amount of $250 USD per charge controller, payable to OutBack Power Technologies, Inc. along with the Warranty Registration. Please submit within 90 days of the first retail sale of the inverter(s). Please indicate the quantity of each product. 110 900-0009-01-00 Rev B Warranty 5-Year Limited Warranty for FLEXmax Products OutBack Power Technologies, Inc. (“OutBack”) provides a five-year (5) limited warranty (“Warranty”) against defects in materials and workmanship for its FLEXmax Series Charge Controller (“Product”). The term of this Warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later. This must be indicated on the invoice, bill of sale, and/or warranty registration submitted to OutBack. This Warranty applies to the original OutBack Product purchaser, and is transferable only if the Product remains installed in the original use location. The warranty does not apply to any Product or Product part that has been modified or damaged by the following: Installation or Removal; Alteration or Disassembly; Normal Wear and Tear; Accident or Abuse; Corrosion; Lightning; Repair or service provided by an unauthorized repair facility; Operation or installation contrary to manufacturer product instructions; Fire, Floods or Acts of God; Shipping or Transportation; Incidental or consequential damage caused by other components of the power system; Any product whose serial number has been altered, defaced or removed; Any other event not foreseeable by OutBack. OutBack’s liability for any defective Product, or any Product part, shall be limited to the repair or replacement of the Product, at OutBack’s discretion. OutBack does not warrant or guarantee workmanship performed by any person or firm installing its Products. This Warranty does not cover the costs of installation, removal, shipping (except as described below), or reinstallation of Products or parts of Products. THIS LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY APPLICABLE TO OUTBACK PRODUCTS. OUTBACK EXPRESSLY DISCLAIMS ANY OTHER EXPRESS OR IMPLIED WARRANTIES OF ITS PRODUCTS, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. OUTBACK ALSO EXPRESSLY LIMITS ITS LIABILITY IN THE EVENT OF A PRODUCT DEFECT TO REPAIR OR REPLACEMENT IN ACCORDANCE WITH THE TERMS OF THIS LIMITED WARRANTY AND EXCLUDES ALL LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION ANY LIABILITY FOR PRODUCTS NOT BEING AVAILABLE FOR USE OR LOST REVENUES OR PROFITS, EVEN IF IT IS MADE AWARE OF SUCH POTENTIAL DAMAGES. IF YOU ARE A CONSUMER THAT PURCHASED THIS PRODUCT IN A MEMBER STATE OF THE EUROPEAN UNION, YOU MAY HAVE ADDITIONAL STATUTORY RIGHTS UNDER DIRECTIVE 1999/44/EC. THESE RIGHTS MAY VARY FROM EU MEMBER STATE TO EU MEMBER STATE. SOME STATES (OR JURISDICTIONS) MAY NOT ALLOW THE EXCLUSION OR LIMITATION OF WARRANTIES OR DAMAGES, SO THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. 900-0009-01-00 Rev B 111 Warranty How to Arrange for Warranty Service During the warranty period beginning on the invoice date, OutBack Power Technologies will repair or replace products covered under this limited warranty that are returned to OutBack Power Technologies’ facility or to an OutBack Power Technologies authorized repair facility, or that are repaired on site by an OutBack Power Technologies authorized repair person. IMPORTANT: For full Warranty description, see previous page. Contacting OutBack To request warranty service: call OutBack Technical Support at +1.360.435.6030, or direct at +1.360.618.4363, or send an email to Technical Support at [email protected]. 10H2 To ensure warranty coverage, this contact must be within the effective warranty period. If service is required, the OutBack Technical Support representative will issue a Return Material Authorization (RMA) number. Troubleshooting In the event of a Product failure, the customer will need to work with an OutBack Technical Support representative to perform the necessary troubleshooting. This is a required step before a return can be performed. Troubleshooting requires a qualified technician to be present at the site of the Product, with a quality voltmeter that measures both DC and AC. The OutBack representative will request voltmeter readings, Product error messages, and other information. Many, many problems can be resolved on-site. If the customer is not willing or able to provide these readings (or is not willing or able to visit the site), and the Product is found to have no problems upon return, OutBack may choose to charge additional labor and handling fees up to $180.00 U.S. Return Material Authorization (RMA) A request for an RMA number requires all of the following information: 1. Product model and serial number; 2. Proof-of-purchase in the form of a copy of the original Product purchase invoice or receipt confirming the Product model number and serial number; 3. Description of the problem; and 4. Shipping address for the repaired or replacement equipment. Upon receiving this information, the OutBack representative can issue an RMA number. 112 900-0009-01-00 Rev B Warranty Returning Product to OutBack After receiving the RMA number, the customer must pack the Product(s) authorized for return, along with a copy of the original purchase invoice and product registration, in the original Product shipping container(s) or packaging providing equivalent or reasonable protection. The RMA number must be written on the outside of the packaging where it is clearly visible. If Product is within the warranty period, OutBack will cover prepaid shipping with prior arrangement. The Product(s) must be shipped back to OutBack Power Technologies in their original or equivalent packaging, to the following address: OutBack Power Technologies RMA # ____________________ 6115 192nd Street NE Arlington, WA 98223 USA The customer must insure the shipment, or accept the risk of loss or damage during shipment. If a shipping box is needed for return of a Product, OutBack will, upon request, send a shipping box. IMPORTANT: OutBack is not responsible for shipping damage caused by improperly packaged Products, the repairs this damage might require, or the costs of these repairs. If, upon receipt of the Product, OutBack determines the Product or Product part is defective and that the defect is covered under the terms of this Warranty, OutBack will then, and only then, ship a repaired or replacement Product or Product part to the purchaser freight prepaid, non-expedited, using a carrier of OutBack’s choice, where applicable. If Product fails in ninety (90) or fewer days from original purchase date, OutBack will replace with a new Product. If Product fails after ninety (90) days and up to expiration of warranty, OutBack will, at its discretion, either repair and return a Product, or ship a replacement Product. OutBack will determine whether a Product is to be repaired or replaced in accordance with Product age and model. OutBack will authorize advance shipment of a replacement based on Product age and model. In cases where an OutBack dealer or distributor replaces a Product more than ninety (90) days old with a new Product, OutBack will NOT compensate that dealer or distributor with new stock unless the exchange was authorized in advance by OutBack. Out of Warranty If Product is out of warranty, OutBack will repair and return Product for a fee. Alternately, if applicable, upon request, OutBack will advance-ship replacement parts for a fee. If a shipping box is needed for return of out-of-warranty Product, OutBack will, upon request, send a shipping box. The customer is responsible for paying shipping to OutBack. The warranty period of any repaired or replacement Product or Product part is ninety (90) days from the date of shipment from OutBack, or the remainder of the initial warranty term, whichever is greater. This Warranty is void for any Product that has been modified by the customer without authorization by OutBack. A Product with a voided warranty will be treated the same as one with an expired warranty. 900-0009-01-00 Rev B 113 Warranty This page intentionally left blank. 114 900-0009-01-00 Rev B Index Index A D Absorb End Amps.......................................................................... 55 Absorb Time Limits ....................................................................... 55 Absorbing................................................................................26, 103 Advanced Menu............................................................................. 52 Absorb End Amps ................................................................... 55 Absorb Time Limits................................................................. 55 Auto ReStart.............................................................................. 58 AUX Polarity .............................................................................. 59 Logging ...................................................................................... 60 MPPT Mode ............................................................................... 53 Rebulk Voltage......................................................................... 56 Reset to Defaults ..................................................................... 59 RTS Compensation ................................................................. 56 Snooze ........................................................................................ 52 Stats.............................................................................................. 61 Vbatt Calibration ..................................................................... 56 Wakeup Mode .......................................................................... 53 AGS .............................................See Automatic Generator Start Applications...................................................................................101 Array Design..................................................................................104 Audience..............................................................................................1 Australian Settings......................................................................105 Auto ReStart ...................................................................... 27, 58, 73 Auto Track ........................................................................................ 53 Automatic Generator Start (AGS) ........................................1, 47 AUX........................................................................................................1 AUX Modes ............................................................................... 33, 72 Diversion .................................................................................... 41 Error Output.............................................................................. 38 Float ............................................................................................. 40 Low Battery Disconnect........................................................ 46 Night Light................................................................................. 39 PV Trigger................................................................................... 37 Remote........................................................................................ 47 Vent Fan...................................................................................... 36 AUX Polarity..................................................................................... 59 AUX Terminals ................................................................................ 17 Data Logging.......................................................25, 60, 67, 75, 81 Default Settings ..................................................................100, 105 Defaults..............................................................................................74 Defaults................................................................................21, 59, 63 Definitions .......................................................................................... 1 Diagrams ......................................................................18, 19, 20, 45 Dimensions.......................................................................................14 Diversion Relay .............................................................................................41 Solid St.........................................................................................43 E Efficiency ........................................................................................ 108 End-of-Day Summary Screen.....................................................24 Equalizing ....................................................................27, 29, 48, 71 Extended Play...........................................................................62, 98 F Features ......................................................................................11, 12 Firmware Revision ...........................................................11, 62, 99 FLEXware...........................................................................................15 Float .......................................................................................... 28, 103 Fuel Cell Applications................................................................ 106 G Graph Screens .................................................................................68 Grid-Tie ..................................................................2, 28, 54, 71, 108 Grounding .................................................................................13, 17 GT Mode .................................................................... 28, 54, 71, 108 H Hydroelectric Applications ...................................................... 106 B Backlight ........................................................................................... 47 Battery Charging..............................................32, 70, 80, 84, 102 Battery Voltage............................................................................... 21 Bulk ............................................................................................28, 102 I Initial Operation..............................................................................30 Installation........................................................................................13 Introduction.....................................................................................11 C L Calibration................................................................................. 56, 74 Charger Setup................................................................... 32, 70, 84 Contact Information........................................................................2 Language ..........................................................................................21 Logging ........................................................................25, 60, 75, 81 900-0009-01-00 Rev B 115 Index M Main Menu ................................................................................ 21, 30 MATE or MATE2 Advanced Menus .................................................................... 83 AUX .............................................................................87 CC ADV.......................................................................85 CHRG ..........................................................................84 EQ ................................................................................86 Menu Map ................................................................90 CC ADV Menu Map .......................................................... 90, 91 CC STATUS Menu Map ................................................... 88, 89 Password .................................................................................... 83 Status Screens .......................................................................... 78 CC LOG.......................................................................81 CC SETPT ...................................................................80 CC STAT .....................................................................82 Menu Map ................................................................88 Meter ..........................................................................79 Mode ..........................................................................78 Summary Screens ................................................................... 77 MATE3 Auxiliary Output ...................................................................... 72 Calibrate ..................................................................................... 74 Charger Settings...................................................................... 70 Device Data Logs..................................................................... 75 Equalization............................................................................... 71 Grid-Tie Mode........................................................................... 71 Menu Structure........................................................................ 69 MPPT............................................................................................ 70 Password .................................................................................... 69 Restart Mode............................................................................. 73 Screens........................................................................................ 65 Temperature Compensation .............................................. 71 Maximum Power Point Tracking.....................................53, 101 Maximum PV Wattage ...............................................................104 Maximum-Power Voltage............................................... 101, 105 Menu Maps ...................................................................................... 31 FLEXmax................................................................ 93, 94, 95, 96 MATE or MATE2 .................................................. 88, 89, 90, 91 MATE3 ......................................................................................... 69 Misc Screen ...................................................................................... 50 Modes ................................................................................................ 26 Absorbing .................................................................................. 26 AutoRestart ................................................................. 27, 58, 73 AutoStart............................................................................. 27, 73 BatTmpErr ........................................................................... 27, 98 BatTooHot.................................................................................. 27 Charged ...................................................................................... 27 EQ ................................................................................................. 27 EQ Done...................................................................................... 27 EX Absorb................................................................................... 28 Floating....................................................................................... 28 GT Mode .............................................................................. 28, 71 High Voc ..................................................................................... 28 Low Light ................................................................................... 28 MPPT Bulk .................................................................................. 28 MPPT EQ ..................................................................................... 29 MPPT Float................................................................................. 28 New Voc...................................................................................... 29 116 Over Temp..................................................................................29 OvrCurrent .................................................................................29 Re-Cal ...........................................................................................29 Sleeping ...............................................................................29, 98 Snoozing.....................................................................................28 Sys Error ......................................................................................29 Tracking.......................................................................................29 Unloaded ....................................................................................30 Wakeup .......................................................................................30 Zzzzz.............................................................................................30 Modes.................................................................................................66 Mounting ..........................................................................................15 MPPT.....................................................................................2, 53, 101 O Open-Circuit Voltage........................................................101, 104 Operation..........................................................................................21 P Password .............................................................................21, 69, 83 Photovoltaic....................................................................................... 2 Ports....................................................................................................17 Powering Up ....................................................................................21 PV Design....................................................................................... 104 R Rebooting the FLEXmax..............................................................63 Rebulk Voltage................................................................................56 Recycling Information .................................................................... 5 Registration................................................................................... 109 Remote Temperature Sensor.................................. 2, 17, 56, 71 Reset to Defaults .......................................................21, 59, 63, 74 Returning Product to OutBack............................................... 113 RTS..........................................See Remote Temperature Sensor S Safety.................................................................................................... 1 Battery ........................................................................................... 4 General .......................................................................................... 2 Inverter .......................................................................................... 3 Personal......................................................................................... 2 PV ................................................................................................... 3 Settings..............................................................................................30 SK ..................................................................................See Soft Keys Snooze Mode...................................................................................52 Soft Keys....................................................................................... 2, 12 Specifications ..................................................................................99 Standard vs. Australian Default Settings............................ 105 STATS Menu ..............................................................................61, 82 Status Screen ............................................................................23, 26 Symbols Used.................................................................................... 1 System Display.................................................................................. 2 MATE or MATE2........................................................................77 MATE3..........................................................................................65 900-0009-01-00 Rev B Index T Vmp.........................................................................................101, 105 Voc...........................................................................................101, 104 Temperature................................................... 29, 56, 71, 103, 104 Terminals .......................................................................................... 17 Three-Stage Battery Charging ................................................102 Troubleshooting ...................................................................97, 112 W U U-Pick ................................................................................................. 53 V Wakeup Mode .................................................................................53 Warranty.....................................................................................2, 111 How to Arrange for Service............................................... 112 RMA ........................................................................................... 112 Terms and Conditions......................................................... 111 Weather Conditions ................................................................... 104 Wiring .......................................................13, 16, 17, 18, 19, 20, 45 Vbatt Calibration..................................................................... 56, 74 900-0009-01-00 Rev B 117 North America 5917 – 195th Street N.E., #7 Arlington, WA 98223 USA +1.360.435.6030 900-0009-01-00 Rev B ">
/
Скачать
Просто дружеское напоминание. Вы можете просмотреть документ прямо здесь. Но самое главное, наш ИИ уже прочитал его. Он может объяснить сложные вещи простыми словами, ответить на ваши вопросы на любом языке и помочь вам быстро перемещаться даже по самым длинным или сложным документам.
Реклама