BEA BEAMBOX User guide
BEA BEAMBOX is a universal activation and presence sensor that offers advanced motion detection and activation capabilities for various applications. With its active infrared technology, it provides precise detection within a 3.3 ft (W) x 3.9 ft (D) zone, making it ideal for automating tasks based on presence or movement. The BEAMBOX features adjustable immunity levels and detection zones, allowing you to customize its sensitivity to suit your specific needs. It also includes a convenient hold time setting, ranging from 0.
Reklama
Reklama
BEAMBOX
Universal activation and presence sensor
User’s Guide
1
DESCRIPTION
A
B
5
6
2
7
8
3
4
1. mounting bracket
2. cable
3. adjustment pin
4. push buttons A, B
TECHNICAL SPECIFICATIONS
Technology:
Detection mode:
Detection zone: active infrared motion and presence
3.3 ft (W) x 3.9 ft (D)
5. detection zone tilt angle adjustment
6. front face
7. LED
8. RC receiver
Reaction time:
Supply voltage:
Mains frequency:
Power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Monitoring input:
Input voltage:
Input current:
Connection on sensor side:
Hold time:
LED-signal:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Cable length:
Material:
Weight:
75.5791.01 BEAMBOX 20140326
< 100 ms
12V - 30V AC ±10%; 12V - 45V DC ±10%
50 - 60 Hz
< 3 W (VA) relay (free of potential change-over contact)
42 V AC - 60 V DC
1A (resistive)
30 W (DC) / 60 VA (AC) optocoupled, free of potential
10V-24V DC
<10mA (@ 24V) unpluggable integrated 7-pin connector
0.5 s to 9 s (adjustable) red and green max. 8.2 ft (flush-mounting)
IP41
-13 °F to + 136 °F (operating); -22 °F to + 140 °F (storage)
5.5 in (W) x 1.5 in (H) x 2.2 in (D)
0° to 20° vertical in steps of 5°
8 ft
Polycarbonate
3.5 oz
Specifications are subject to changes without prior notice - Measured in specific conditions.
Page 1 of 4
1
MOUNTING & WIRING
R max
0.59
M3 x 10
2.7
3.1
1.5
All dimensions are in inches
2
MECHANICAL ADJUSTMENTS
1 2 3
Loosen the screws to adjust the brackets to your application if necessary.
RED - POWER SUPPLY +
BLACK - POWER SUPPLY -
WHITE - COM
GREEN - NO
YELLOW - NC
PURPLE - MONITORING +
BLUE - MONITORING -
«click»
Typ. detection zone dimensions
(at 6.6 ft with all spots activated):
0° = 39 in (W) x 39 in (D)
20° = 39 in (W) x 47 in (D)
1
2
Page 2 of 4
A
B
Without remote control, you can set two parameters using the push buttons:
PUSH BUTTON A: IMMNUNITY (1-4)
- Push once to enter into programming mode. The red LED flashes.
The number of flashes indicates the current value (see next page).
- Push again to increment the immunity. The red LED indicates the new setting.
When you reach value 4 and push again, the immunity skips to value 1 (rolling system).
- Push button B to close the session, once you have reached the required immunity value.
PUSH BUTTON B: DETECTION ZONE (1-9)
- Push once to enter into programming mode. The green LED flashes.
The number of flashes indicates the current value (see next page).
- Push again to go to the next value. The green LED indicates the new selected field.
When you reach value 9 and push again, you will go back to value 1 (rolling system).
- Push button A to close the session, once you have reached the required sensitivity value.
If no button has been pushed for 1 minute, the programming mode is automatically ended.
75.5791.01 BEAMBOX 20140326
3
DETECTION ZONES
door + sensor
(top view)
4
SETTINGS
inactive spot active spot - motion active spot - presence mounting height: 6.6 ft - tilt angle: 20°
TIP!
Use the Spotfinder to check the position of the activated IR-spots.
IMMUNITY
PULSE FREQUENCY
OUTPUT
CONFIGURATION
HOLD TIME
MAX. DURATION
OF PRESENCE
DETECTION
DOOR CONTROL lower low high higher
0.5 s low med high
A
1 s
P
2 s 3 s
A = active output (NO-contact)
P = passive output (NC-contact)
4 s 5 s 6 s 7 s 8 s 9 s
20 s 1 min 2 min 3 min 5 min 7 min 10 min 15 min 20 min 25 min auto open closed open = sensor is continuously in detection > LED ON closed = sensor is in standby and does not detect > LED OFF
CHECKING A VALUE:
> x = number of flashes = value of the parameter
75.5791.01 BEAMBOX 20140326
> x
FACTORY VALUES:
LAUNCHING SETUP:
+
+
Page 3 of 4
TROUBLE SHOOTING
The sensor will not power up.
The door opens and closes constantly.
Faulty power supply.
1 Check power supply.
The sensor is disturbed by the door motion or vibrations.
1
2
Increase the tilt angle of the sensor.
Verify if the sensor is mounted correctly.
Two sensors in proximity to each other are disturbed.
The overlapping detection fields create interferences.
The sensor does not respond to the remote control.
Batteries in the remote control are weak or installed improperly.
Remote control oriented poorly.
The sensor is doing a setup.
1
1
1
Choose a different pulse frequency for each sensor.
Check and change the batteries if necessary.
Point the remote control towards the sensor.
1 Cycle power supply.
Stand outside of the detection zone until the setup is finished.
The sensor does not unlock when the access code is entered.
The red LED flashes quickly.
Incorrect access code.
The sensor goes into security mode after a faulty internal test.
1 Cycle power supply.
No code is required during the 1st minute after power on. Set new access code by following the steps below.
1 Replace sensor.
ACCESS CODE
The access code (1 to 4 digits) is recommended for sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor. If you forget the access code,
cycle the power supply. For the first minute, you can access the sensor without introducing any access code.
•
•
•
The device should not be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety.
The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
ANSI / AAADM Compliance
A A ADM American Association of
Automatic Door Manufactures
Upon completion of the installation or service work, at a minimum, perform a daily safety check in accordance with the minimum inspection guidelines provided by AAADM. Provide each equipment owner with an owner’s manual that includes a daily safety checklist and contains, at a minimum, the information recommended by AAADM. Offer an information session with the equipment owner explaining how to perform daily inspections and point out the location of power/operation switches to disable the equipment if a compliance issue is noted. The equipment should be inspected annually in accordance with the minimum inspection guidelines. A safety check that includes, at a minimum, the items listed on the safety information label must be performed during each service call. If you are not an AAADM certified inspector, BEA strongly recommends you have an AAADM certified inspector perform an AAADM inspection and place a valid inspection sticker below the safety information label prior to putting the equipment into operation.
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com