Murphy MC Series Millennium Controller Installation Diagram
Murphy MC Series Millennium Controller provides precise control and monitoring of various industrial processes in hazardous environments. With its rugged construction and advanced features, it ensures reliable performance and flexibility for demanding applications. The controller offers:
- Explosion-proof design for safe operation in Class I, Division 2, Groups C and D hazardous locations
- Versatile I/O options, including discrete inputs, outputs, analog inputs, and serial communication ports
- User-friendly interface with a backlit LCD display for easy configuration and monitoring
- Powerful control capabilities with programmable logic, PID control loops, and timers/counters
PDF
Dokumen
Iklan
Iklan
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS | DIVISION 2 WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA 18 KNOWN TO BE pa pu © B 3 | Ё OR MODEM \М I 1/0 EXPANSION C267, C277, C287 MCCA72 PART # 50-05-0782 MILLENNIUM HEAD MODEL NUMBERS REF. DWG 50-00-0385 THIS EQUIPMENT IS SUITABLE FOR USE IN CLI, DIV2 GRPS. C,D (T3) HAZARDOUS LOCATIONS. SEE NOTE® TS SENSOR INPUT CONFIGURED FOR SENSOR WITH SINGLE WIRE TO GROUND. nos DL SENSOR INPUT CONFIGURED FOR SENSOR WITH SINGLE WIRE TO POWER SUPPLY POSITIVE. db TS ss —o fo ———- =O SENSOR INPUT CONFIGURED FOR TWO WIRE INPUT. dL TS ss —o fo ———- SENSOR INPUT CONFIGURED FOR TWO WIRE INPUT. JSI 5 5 +\6 SHUNT INSTALLED IN JSI ONLY + se 1 JSI o +VS SHUNT INSTALLED IN JS2 ONLY , FR Js2 | JSI o +Vs SHUNT NOT REQUIRED 3 us? L JSI o— +Vs SHUNT NOT REQUIRED us ye L 1/P МР RS&85 SERIAL 1/0 COMA I0A, 125VAC, SA, 30VDC TYPICAL FOR ALL FOUR MAXIMUM LOAD 3A RELAY OUTPUTS MD POWER INPUT | LOAD MAXIMUM INES LOAD 3A pos 000 MAXIMUM — — — — — LOAD 3A - — — — — NEG _ _— — — — “400 _ MAXIMUM POS LOAD 3A HH MILLENNIUM POWER SUPPLY MODEL NUMBERS MCPS-NA PART # 50-70-0508 MCPS-Al PART 4 50-70-0306 MCPS-A2 PART # 50-70-0307 REF. DWG 50-00-0357 ICDB CONNECTOR 7 JR-I — rh CHGND — + <Q © TSS J! || b + sel O | n-2omA ® 420 (O | CURRENT SOURCE H SHG 3 L-20MA + MAGNETIC PICKUP +20 (©) | CURRENT SOURCE wh 1 20 (©) + 0 oN SHG 3 ® = alo ; 5 : © = TS3 OOOOOOOO OOOOOOO0O |0000000000000000|0000000000000000| up NON-INCENDIVE FIELD WIRING CONNECTIONS TO NOTES: (D) FIELD WIRING CONNECTIONS TO BE INSTALLED IN ACCORDANCE WITH THE NEC FOR CLASS |, DIV 2, GRPS C AND D HAZARDOUS LOCATIONS. (2) INSTALL SEPARATE CONDUCTORS FOR SSR AND CONTROLLER POWER INPUT. ALLOW FOR CONDUCTOR VOLTAGE DROP WHEN DETERMINING CONDUCTOR SIZE. ALL POWER SUPPLIES MUST HAVE COMMON GROUND. (3) FOR AN INDUCTIVE LOAD, INSTALL A DIODE IN PARALLEL WITH THE LOAD. USE A FAST RECOVERY 3A, S0PIV DIODE. MOUNT DIODE AS CLOSE AS POSSIBLE TO THE LOAD DEVICE. MAXIMUM LOAD INDUCTANCE: IH @ 0.25A, SMH @ SA. (4) RL = (Ves - 3.15)/0.20 RL = LOOP RESISTANCE VPS = POWER SUPPLY VOLTS (5) SENSOR SWITCH INPUT CURRENT: 2.5MA MAX @ IOVDC, 9.2MA @ 52VDC © MINIMUM CHARGE/DISCHARGE CYCLE TIME 9 MIN. b + 0 я * | PASSIVE SWITCHES FOR E 4 || USE IN CLI, DIV2, GRPS C TYPICAL NORMALLY | $ AND D HAZARDOUS CLOSED SENSOR FOR A * | LOCATIONS. ROUTE USE IN CLI, DIVZ, К 4 || SWITCH LEADS SEPERATE GRPS, C AND D | ı | FROM ALL OTHER WIRING. HAZARDOUS E 2 LOCATIONS. 0 O 2 s+ 020 10 Ne +) _ | SG Lt | A TYPICAL NORMALLY | 00 2 FT) __NO ST com OPEN SENSOR FOR | e о Л USE IN CLI, DIV2, | $ | GRPS, C AND D 38390 © E HAZARDOUS | ER _ | SSR POWER SUPPLY — LOCATIONS. | oO = Flea] LEADS | —_— | ME © Е L Г 0 15 ELE A ami. | A — © в ия E | EN EE O aa NEG 23 AL e JA Es" o — + O NM В O POSmm mmm Do = 15 О Eo] E O Nec == = | | POWER SUPPLY | | Hee O pose — =) == == —= = || 10-32VDC | ——— O сы : С) |МЕСищнни | | | 49 BO} ea gy бе 8 O a - O = пн — пин = O 68 1 — Bp ros | | og gol | 50 || ql |_ 7 | | VE © =~ | | \ -— 7 | | | o 4-0 WARNING - EXPLOSION HAZARD - DO NOT | L mes) NEG DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN | USER SUPPLIED | SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS | ©| © — POWERSUPPLY | == mm) POS AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTER MCCP PART # 50-70-0326 L' EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE REF DWG 50-00-0395 NON DANGEREUX. С REMOVED MILLENNIUM HEAD MODEL NUMBERS: 50700302, 50700303, 50700304 8 50700305 02-26-02 02-0155 | DPMc | DMc UNLESS NOTED OTHERWISE NTS x) murph WRB RH ® INSTALLATION DIAGRAM MILLENNIUM CONTROLLER 90-08-0040 | C ">
/
Unduh
Hanya pengingat ramah. Anda dapat melihat dokumen di sini. Tetapi yang paling penting, AI kami telah membacanya. Ia dapat menjelaskan hal-hal kompleks dengan istilah sederhana, menjawab pertanyaan Anda dalam bahasa apa pun, dan membantu Anda menavigasi dengan cepat bahkan dokumen terpanjang atau paling rumit.
Iklan