The Viessmann VITOTROL 100 is a cutting-edge room thermostat that offers a variety of programmable settings to optimize your home's heating system for energy efficiency and comfort. With its intuitive user interface and customizable time programs, you can tailor your heating schedule to your specific needs, ensuring a warm and welcoming home when you need it most.
விளம்பரம்
விளம்பரம்
Operating instructions
for the system user
Room thermostat
Type UTDB-RF2
VIESMANN
VITOTROL 100
5592 620 GB 6/2010
Please keep safe.
2
Safety instructions
For your safety
Please follow these safety instructions closely to prevent accidents and material losses.
Safety instructions explained
Danger
This symbol warns against the risk of injury.
!
Please note
This symbol warns against the risk of material losses and environmental pollution.
Note
Details identified by the word "Note" contain additional information.
Target group
These operating instructions are for the heating system user.
This unit is not designed to be used by persons (including children) with limited bodily, sensory or mental capacities, or lacking experience and/or lacking knowledge, unless they are supervised by a person responsible for their safety, or have received instructions from such a person as to how to use the unit.
!
Please note
Children should be supervised.
Ensure that children do not play with the unit.
Danger
Incorrectly executed work on the heating system can lead to lifethreatening accidents.
■ Work on gas appliances must only be carried out by a registered gas fitter.
■ Work on electrical equipment must only be carried out by a qualified electrician.
If you smell gas
Danger
Escaping gas can lead to explosions which may result in serious injury.
■ Do not smoke. Prevent naked flames and sparks. Never switch lights or electrical appliances ON or OFF.
■ Close the gas shut-off valve.
■ Open windows and doors.
■ Remove all people from the danger zone.
■ Notify your gas or electricity supplier and your heating contractor from outside the building.
■ Shut off the electricity supply to the building from a safe place
(outside the building).
Safety instructions
For your safety
(cont.)
If you smell flue gas
Danger
Flue gas can lead to life-threatening poisoning.
■ Shut down the heating system.
■ Ventilate the boiler room.
■ Close all doors in the living space.
In case of fire
Danger
Fire creates the risk of burning and explosions.
■ Shut down the heating system.
■ Close the shut-off valves of the fuel lines.
■ Use a tested fire extinguisher, class ABC.
Boiler room requirements
!
Please note
Incorrect ambient conditions can lead to damage to the heating system and put the safe operation at risk.
■ Ensure ambient temperatures above 0 ºC and below 35 ºC.
■ Prevent air contamination by halogenated hydrocarbons
(e.g. as contained in paints, solvents or cleaning fluids) and excessive dust (e.g. through grinding/polishing work).
■ Avoid continuously high humidity levels (e.g. through frequent drying of washing).
■ Never close existing ventilation apertures.
Ancillary components, spare and wearing parts
!
Please note
Components that are not tested with the heating system may lead to damage to the heating system, or may affect their various functions.
Installation or replacement work must only be carried out by qualified personnel.
3
Index
Index
■ Manual (operation with constant room temperature)........................................ 12
Changing the room temperature for a few days only........................................... 15
Changing the room temperature for a few hours only.......................................... 16
■ Time program for central heating on the current day for Prog 1 to Prog 3....... 25
Scanning holiday program (if programmed)......................................................... 25
4
Index
Index
(cont.)
5
Where to find the controls
Summary of controls and indicators
Opening the flap
6
Where to find the controls
Summary of controls and indicators
(cont.)
Functions
L
K
H
G
å
û g
|
ä
|
OK
A
B
C
D
E
F
A Display
or
Change adjustable values
or
Change adjustable values
Symbols on the display
These symbols are not always displayed, but appear subject to the operating condition.
D Reset
E Open flap
F Type plate
G Battery compartment
H Confirmation
K 1 step back in the menu
L Calling up menu
7
8
Where to find the controls
Summary of controls and indicators
(cont.)
A B
0
We 01.01.09
21.5°C
6 12 18
C
24
D
E
F
A Weekday
B Date
C Time
D Selected time program
Display backlighting
The backlighting of the display is activated by pressing any key and goes out
15 s after the last key was pressed.
E Current room temperature
F Time program shown as time slot graphic r
Heat demand for central heating
Heat demand for DHW heating
Þ
Party mode enabled
û
Economy mode enabled
Manual mode enabled j
Holiday program enabled
Frost protection mode enabled
Î
Changing the batteries
Controls locked out
How to operate the controls
Standard display
21.5°C
When idle, the display always shows the current room temperature.
■ Pressing any key takes you to the operating display.
■ Pressing key twice calls up this menu.
■ With takes you one step back in the menu.
■ The menu will automatically close
30 s after the last key was pressed.
The standard display will be shown
3 min later.
Any changes are accepted with OK.
Temperature changes made with keys
/ will be automatically accepted after approx. 5 s.
How to operate the controls
(cont.)
Lock out controls
You can lock the control keys of the
Vitotrol 100. For this, press keys and
simultaneously for approx. 5 s. To unlock the keys, press and again simultaneously for 5 s.
Where to find the controls
9
Central heating
Selecting the operating mode
You can select between the following operating modes:
■ Heating mode
In this operating mode, there are three preset programs available to you
("Prog 1" to "Prog 3") (see next chapter).
Heating alternates with standard room temperature ("Comfort") and two reduced room temperatures ("Eco" and "Reduced").
■ "Frost pr.": Frost protection operation
■ "Manual": Operation with a constant
room temperature (see page 12)
Heating mode
You can choose from three preset time programs ("Prog 1" to "Prog 3").
Note
You can change the time programs in accordance with your individual require-
In the time programs, you can change between three temperature values:
■ "Comfort" (delivered condition:
21 °C)
■ "Eco" (delivered condition: 19 °C)
■ "Reduced" (delivered condition:
16 °C)
Preset time programs
Time program 1 – Prog 1
2
3
4
5
6
Monday to Friday
Time phase Start
1 06:00
08:00
12:00
14:00
18:00
22:00
End
08:00
12:00
14:00
18:00
22:00
06:00
Note
You can change the temperatures in accordance with your individual require-
1. Open the flap.
2. Press twice .
3. Select with / (e.g. "Prog 1").
4. Confirm with OK.
The heating program proceeds according to the selected time program.
Room temperature
Comfort
Comfort
Comfort
Comfort
Comfort
Reduced
10
Central heating
Selecting the operating mode
(cont.)
3
4
5
6
1
2
Saturday and Sunday
Time phase Start
07:00
08:00
12:00
14:00
16:00
23:00
Time program 2 – Prog 2
2
3
4
5
6
Monday to Friday
Time phase Start
1 06:00
08:00
12:00
14:00
16:00
22:00
4
5
6
1
2
3
Saturday and Sunday
Time phase Start
07:00
08:00
12:00
14:00
18:00
23:00
Time program 3 – Prog 3
2
3
4
5
6
Monday to Friday
Time phase Start
1 06:00
08:00
12:00
14:00
18:00
23:00
End
08:00
12:00
14:00
18:00
23:00
07:00
End
08:00
12:00
14:00
16:00
23:00
07:00
End
08:00
12:00
14:00
18:00
23:00
06:00
End
08:00
12:00
14:00
16:00
22:00
06:00
Room temperature
Comfort
Comfort
Comfort
Comfort
Comfort
Reduced
Room temperature
Comfort
Reduced
Reduced
Reduced
Comfort
Reduced
Room temperature
Comfort
Comfort
Comfort
Comfort
Comfort
Reduced
Room temperature
Comfort
Eco
Comfort
Eco
Comfort
Reduced
11
Central heating
Selecting the operating mode
(cont.)
3
4
5
6
1
2
Saturday and Sunday
Time phase Start
07:00
08:00
12:00
14:00
18:00
23:00
Frost protection mode
End
08:00
12:00
14:00
18:00
23:00
07:00
If you do not want to heat the rooms but would like to have frost protection.
Central heating starts if the room temperature falls below 5 °C.
Note
DHW heating is OFF.
1. Open the flap.
Room temperature
Comfort
Comfort
Comfort
Comfort
Comfort
Reduced
2. Press twice .
3. Select with / "Frost pr."
4. Confirm with OK.
The display shows and then the current room temperature.
Manual (operation with constant room temperature)
Central heating operates constantly with the selected temperature.
1. Open the flap.
2. Press twice .
3. Select with / "Manual".
4. Confirm twice with OK.
Note
At this point, you can also start or stop
DHW heating during this operating mode (see chapter "DHW heating").
5. With / set the required room temperature (min. 10 °C).
6. Confirm with OK.
The display shows and then the current room temperature.
12
Central heating
Setting a permanent room temperature
You can select the following temperatures:
■ Room temperature "Comfort" (standard room temperature)
Setting in the delivered condition:
21 °C
Setting range: 10 to 40 °C
■ Room temperature "Eco"
Setting in the delivered condition:
19 °C
Setting range: 10 to 40 °C
■ Reduced room temperature
"Reduced"
Setting in the delivered condition:
16 °C
Setting range: 10 to 40 °C
0
1. Open the flap.
0
2. Press twice .
0
3. Select with / "SETTINGS".
0
4. Confirm with OK.
0
5. With / set the "Tmp settings".
0
6. Confirm with OK.
0
7. With / set the required temperature for "Comfort".
0
8. Confirm with OK.
0
9. With / set the required temperature for "Eco".
10. Confirm with OK.
11. With / set the required temperature for "Reduced".
12. Confirm with OK.
Setting an individual time program
Setting time phases
In the preset time programs "Prog 1" to
"Prog 3", the day is split into six time phases.
However, you can also split the day into less than six time phases:
■ For time phase 1, always select "Time
ph. 1".
and
■ For the last time phase, always select
"Time ph. 6".
Example:
In "Prog. 3", you only want to enable three time phases. "Comfort" from
06:00 h to 10:00 h; "Eco" from 10:00 h to 22:00 h; and "Reduced" from 22:00 h to 06:00 h.
Select "Time ph. 1", "Time ph. 2" and
"Time ph. 6".
Time phases 3, 4 and 5 are automatically disabled.
For every enabled time phase, the following must be entered:
■ Start time
■ Stop time
■ Temperature ("Comfort", "Eco",
"Reduced")
13
Central heating
Setting a permanent room temperature
(cont.)
You can select time phases for several days (day groups) or for individual days:
■ "MO–SU" for the same time phases every day of the week
■ "MO–FR" for the same time phases
Monday to Friday
■ "SA–SU" for the same time phases on
Saturday and Sunday
■ "SINGLE DAY" different time phases for single days
Note
Settings for individual days take priority over settings for several days.
0
1. Open the flap.
0
2. Press twice .
0
3. Select with / "SETTINGS".
0
4. Confirm with OK.
0
5. Select with / "Programs".
0
6. Confirm with OK.
0
7. With / select the program you want to change (e.g. "Prog 1").
0
8. Confirm with OK.
0
9. Select with / "Heating circuit".
10. Confirm with OK.
11. Select with / "Set".
12. Confirm with OK.
13. Select with / the required day group/individual day.
14
14. Confirm with OK.
15. Select with / the time phase or first the required day.
16. Confirm with OK.
17. With / set the required start time, stop time and the temperature, one after the other (e.g."Reduced").
18. Confirm respectively with OK.
19. Proceed as described in points 15 to
18 to set further time phases.
Note
Should gaps be created between the time phases, these are closed automatically by an extension to the previous time phase.
Disabling time phases
To disable a time phase, set the same value for the start and stop times.
Copying a time program
You can copy time programs, for example to make a new time program from another where only minor changes are required.
0
1. Open the flap.
0
2. Press twice .
0
3. Select with / "SETTINGS".
0
4. Confirm with OK.
0
5. Select with / "Programs".
Central heating
Setting a permanent room temperature
(cont.)
0
6. Confirm with OK.
0
7. Select with / the program you want to change (e.g. "Prog 1").
0
8. Confirm with OK.
0
9. Select with / "Heating circuit".
10. Confirm with OK.
11. Select with / "Copy from".
12. Confirm with OK.
13. Select with / the program you want to copy.
14. Confirm with OK.
15. Select with / "Set" to make changes.
Changing the room temperature for a few days only
Setting the holiday program
When you are away on holiday, the following energy saving options are available:
■ You can shut the central heating down completely by selecting frost protec-
tion mode "Frost pr." (see page 12).
or
■ You can set the central heating to minimum energy consumption (e.g. to prevent your house plants from being damaged by frost). To do so, select the holiday program "j".
When the holiday program is enabled, the rooms are heated with the reduced room temperature ("Reduced").
Note
DHW heating is OFF.
1. Open the flap.
2. Press twice .
3. Select with / "Holiday"
4. Confirm with OK.
5. Select with / "ON".
6. Confirm with OK.
7. With / set the required day and time for start and end of the holiday program.
8. Confirm respectively with OK.
Terminating the holiday program
■ The holiday program terminates automatically when the end time has been reached
■ If you want to delete the holiday program early:
1. Open the flap.
2. Press twice .
15
Central heating
Changing the room temperature for a few days…
(cont.)
3. Select with / "Holiday"
4. Confirm with OK.
5. Select with / "OFF".
Changing the room temperature for a few hours only
You can change the room temperature for a few hours without permanently altering the settings.
The modified temperature remains enabled until the next changeover within a program or until the next program change.
If you want to raise the room temperature unexpectedly:
■ In programs "Prog 1" to "Prog 3" and
"Manual", you can increase the room temperature with (see the following chapter).
or
■ Press g to select party mode (only in programs "Prog 1" to "Prog 3"; see
Change with keys /
1. Press / .
The current set temperature will be displayed.
2. With / set the required temperature.
Setting party mode
In party mode, the reduced room temperature will be raised automatically to the selected standard room temperature
("Comfort").
If you want to lower the room temperature unexpectedly:
■ In programs "Prog 1" to "Prog 3" and
"Manual" you can decrease the room temperature with (see the following chapter) or
■ Press û to select economy mode
(only in programs "Prog 1" to
3. The value is accepted automatically after approx. 5 s.
Note
DHW heating is ON.
1. Press g for approx. 5 s.
The display shows Þ.
16
Central heating
Changing the room temperature for a few hours…
(cont.)
2. With / you can also change the temperature.
3. The value is accepted automatically after approx. 5 s.
Setting economy mode
In economy mode, the room temperature is reduced automatically by 2 °C.
Note
DHW heating is OFF.
1. Press û for approx. 5 s.
The display shows û.
2. With / you can also change the temperature.
3. The value is accepted automatically after approx. 5 s.
Terminating economy mode
■ Economy mode ends automatically the next time the heating program changes over.
■ If you want to terminate economy mode early, press û again for approx.
5 s.
Terminating party mode
■ Party mode ends automatically the next time the program changes over.
■ If you want to terminate party mode early, press g again for approx. 5 s.
17
DHW heating
Starting and stopping DHW heating
1. Open the flap.
2. Press twice .
3. Select with / "Manual".
4. Confirm with OK.
5. With / set "DHW" "ON" or
"OFF".
6. Confirm with OK.
Selecting the time program
You can choose between three preset time programs. They are saved in the programs" Prog 1" to "Prog 3" (see
In the time programs, there is a changeover between operating modes "Ena-
ble" and "Block".
Preset time programs
Time program 1 – Prog 1
3
4
5
6
1
2
Monday to Friday
Time phase Start
05:30
08:00
12:00
14:00
18:00
22:00
2
3
4
5
6
Saturday and Sunday
Time phase Start
1 06:30
08:00
12:00
14:00
16:00
23:00
End
08:00
12:00
14:00
18:00
22:00
05:30
End
08:00
12:00
14:00
16:00
23:00
06:30
Note
You can change the time programs in accordance with your individual require-
Operating mode
Enable
Enable
Enable
Enable
Enable
Block
Operating mode
Enable
Enable
Enable
Enable
Enable
Block
18
Selecting the time program
(cont.)
Time program 2 – Prog 2
3
4
5
6
1
2
Monday to Friday
Time phase Start
05:30
08:00
12:00
14:00
15:30
22:00
2
3
4
5
6
Saturday and Sunday
Time phase Start
1 06:30
08:00
12:00
14:00
18:00
23:00
Time program 3 – Prog 3
4
5
6
1
2
3
Monday to Friday
Time phase Start
05:30
08:00
12:00
14:00
18:00
22:00
2
3
4
5
6
Saturday and Sunday
Time phase Start
1 06:30
08:00
12:00
14:00
18:00
23:00
End
08:00
12:00
14:00
15:30
22:00
05:30
End
08:00
12:00
14:00
15:30
22:00
05:30
End
08:00
12:00
14:00
18:00
23:00
06:30
End
08:00
12:00
14:00
18:00
23:00
06:30
Operating mode
Enable
Block
Block
Block
Enable
Block
Operating mode
Enable
Enable
Enable
Enable
Enable
Block
Operating mode
Enable
Block
Block
Block
Enable
Block
Operating mode
Enable
Enable
Enable
Enable
Enable
Block
DHW heating
19
DHW heating
Selecting the time program
(cont.)
Setting an individual time program
Setting time phases
In the preset time programs "Prog 1" to
"Prog 3", the day is split into 6 time phases.
For every enabled time phase, the following must be entered:
■ Start time
■ Stop time
■ Operating modes "Enable", "Block"
You can select time phases for several days (day groups) or for individual days:
■ "MO–SU" for the same time phases every day of the week
■ "MO–FR" for the same time phases
Monday to Friday
■ "SA–SU" for the same time phases on
Saturday and Sunday
■ "SINGLE DAY" different time phases for single days
Note
Settings for individual days take priority over settings for several days.
0
1. Open the flap.
0
2. Press twice .
0
3. Select with / "SETTINGS".
0
4. Confirm with OK.
0
5. Select with / "Programs".
0
6. Confirm with OK.
0
7. Select with / the program you want to change (e.g. "Prog 1").
0
8. Confirm with OK.
0
9. Select with / "DHW".
10. Confirm with OK.
11. Select with / "Set".
12. Confirm with OK.
13. Select with / the required day group/individual day.
14. Confirm with OK.
15. Select with / the time phase or first the required day.
16. Confirm with OK.
17. With / set the required start time, stop time and the temperature, one after the other (e.g."Block").
18. Confirm respectively with OK.
19. Proceed as described in points 15 to
18 to set further time phases.
Note
Should gaps be created between the time phases, these are closed automatically by an extension to the previous time phase.
20
DHW heating
Selecting the time program
(cont.)
Disabling time phases
To disable a time phase, set the same value for the start and stop times.
Copying a time program
You can copy time programs, for example to make a new time program from another where only minor changes are required.
0
1. Open the flap.
0
2. Press twice .
0
3. Select with / "SETTINGS".
0
4. Confirm with OK.
0
5. Select with / "Programs".
0
6. Confirm with OK.
0
7. With / select the program you want to change (e.g. "Prog 1").
0
8. Confirm with OK.
0
9. Select with / "DHW".
10. Confirm with OK.
11. Select with / "Copy from".
12. Confirm with OK.
13. Select with / the program you want to copy.
14. Confirm with OK.
15. Select with / "Set" to make changes.
21
Further adjustments
Time and date
1. Open the flap.
2. Press twice .
3. Select with / "SETTINGS".
4. Confirm with OK.
5. Select with / "Standard set-
tings".
6. Confirm with OK.
7. Select with / "Date - time".
8. Confirm with OK.
9. With / set the current day and time.
10. Confirm respectively with OK.
Summertime/wintertime
The changeover from summer to wintertime and vice-versa is automatic. You can disable the automatic changeover.
1. As described on page 22 select
"Date - Time".
2. With OK select "Summertime ON".
3. Select with / "OFF".
4. Confirm with OK.
Selecting the language
1. Open the flap.
2. Press twice .
3. Select with / "SETTINGS".
4. Confirm with OK.
5. Select with / "Standard set-
tings".
6. Confirm with OK.
7. Select with / "Language".
8. With / set the required language.
9. Confirm with OK.
Renaming programs
You can individually rename programs
"Prog 1" to "Prog 3". The designation is limited to 5 characters.
22
0
1. Open the flap.
0
2. Press twice .
Further adjustments
Renaming programs
(cont.)
0
3. Select with / "SETTINGS".
0
4. Confirm with OK.
0
5. Select with / "Program".
0
6. Confirm with OK.
0
7. Select with / the program you want to rename (e.g. "Prog 1").
0
8. Confirm twice with OK.
0
9. Select with / "Rename".
10. Confirm with OK.
11. In the line "New name", with / enter the required symbols one after the other.
12. Confirm respectively with OK.
Temperature adjustment
The displayed room temperature can deviate from the actual room temperature if your Vitotrol 100 is installed in an unfavourable position, e.g. on an external wall or near a chimney. You can correct this temperature deviation with a compensator.
Example:
The room temperature displayed by the
Vitotrol 100 is 2 ºC higher than the actual room temperature. The correction is then
−2 ºC.
1. Open the flap.
2. Press twice .
3. Select with / "SETTINGS".
4. Confirm with OK.
5. Select with / "Service".
6. Confirm with OK.
7. With OK select the required value to be set for "Ctrller offset".
8. With / set the required value.
9. Confirm with OK.
10. Exit the menu with .
Control characteristics
The hysteresis controller is factory-set.
The hysteresis value influences the start and stop points for "Heating" or "Not heating".
Example:
Set room temperature: 21 °C
Hysteresis: 0.6 °C (delivered condition).
Setting range: 0.2 to 1.0 °C.
23
Further adjustments
Control characteristics
(cont.)
Heating stops as soon as the actual room temperature exceeds 21.3 °C.
Heating starts as soon as the actual room temperature falls below 20.7 °C.
You can change the control characteristics by changing the hysteresis value.
Select a lower value if your system responds too slowly.
1. Open the flap.
2. Press twice .
3. Select with / "SETTINGS".
4. Confirm with OK.
5. Select with / "Service".
6. Confirm with OK.
7. With / set the required hysteresis value.
8. Confirm twice with OK.
9. Exit the menu with .
24
Scanning options
Scanning temperatures and further settings
1. Press .
The display shows the following details:
■ Weekday
■ Date and time
■ Current program
■ Current room temperature
2. With / call up the current set temperature.
Scanning time programs
Time program for central heating on the current day for Prog 1 to Prog 3
The display shows the time phases for the current day on a time slot graphic.
0
Example:
We 01.01.09
6
21.5°C
12 18
A B
24
Central heating from 06:00 A to 22:00 h B with standard room temperature
("Comfort") and central heating from
22:00 to 06:00 h with reduced room temperature ("Reduced").
Scanning holiday program (if programmed)
1. Open the flap.
2. Press twice .
3. Select with / "Holiday"
4. Confirm with OK.
Start and end of the set holiday period are displayed.
25
What to do if...
Rooms are too cold
Cause
Vitotrol 100 is incorrectly set up.
The wireless connection to the boiler control unit is faulty.
Remedy
Check and correct settings if required:
■ Room temperature (see page 13)
Change the address code (see
Note
For further causes, see the boiler operating instructions.
Rooms are too hot
Cause
Vitotrol 100 is incorrectly set up.
Remedy
Check and correct settings if required:
■ Room temperature (see page 13)
Note
For further causes, see the boiler operating instructions.
There is no hot water
Cause
Vitotrol 100 is incorrectly set up.
The wireless connection to the boiler control unit is faulty.
Remedy
Check and correct settings if required:
■ Starting DHW heating (see page 18)
■ Operating mode (see page 18)
Change the address code (see
Note
For further causes, see the boiler operating instructions.
26
What to do if...
Î
flashes in the display
Cause
The batteries are spent.
Remedy
Change the batteries (see next chapter).
The Vitotrol 100 has a battery backup of
3 min. If you replace the batteries within this time, all set details will be retained.
After the power reserve has been exceeded, carry out a reset (see next chapter).
Note
If the batteries are not changed, the display switches off.
Central heating and DHW heating are carried out according to the settings on the boiler control unit.
Changing the batteries
Disposal
Batteries/rechargeable batteries should not be disposed of in domestic waste.
Always dispose of spent batteries/ rechargeable batteries via an authorised collection site.
■ Use only alkaline batteries, 1.5 V
Mignon alkaline cells, type LR6/AA that do not contain noxious substances.
■ Never use rechargeable batteries.
■ Replace both batteries every 18 months.
27
What to do if...
Changing the batteries
(cont.)
Reset
2.
- +
+ -
3.
1.
Press the reset button with a suitable instrument. After a reset, re-enter the language, time and date.
28
What to do if...
Changing the address code
Wireless receiver on the boiler
Once the address code is recognised, the LEDs go out; otherwise repeat the procedure.
A
8 Q ë r w
B
A LED
1. Press B on the wireless receiver for approx. 10 s until LED r flashes.
2. Open the flap of the Vitotrol 100.
3. Press twice .
4. Select with / "SETTINGS".
5. Confirm with OK.
6. Select with / "Service".
7. Confirm three times with OK.
8. Select with / "Address code".
9. Confirm with OK.
After approx. 30 s the display shows
"Transmitting".
The transfer takes approx. 30 s.
During the transfer, the LED flashes briefly .
29
Appendix
Cleaning
The device can be cleaned with a commercially available domestic cleaning agent (non-scouring).
Energy saving tips
Use the Vitotrol 100 setting options:
■ Do not overheat your rooms.
Every degree of room temperature reduction saves up to 6% of your heating bills.
Never set your room temperature
higher than 20 °C (see page 13).
■ Select the program that meets your current requirements:
– For short absences (e.g. shopping trips), select "Economy mode"
As long as economy mode is activated, the room temperature is reduced and DHW heating is off.
– If you are going away, set the "Hol-
As long as the holiday program is activated, the room temperature is reduced and DHW heating is off.
– If you don't want to heat the rooms and you don't require DHW for an extended period, select operating
mode "Frost pr." (see page 12).
Further recommendations:
■ Correct ventilation/airing.
Briefly open windows fully and at the same time close the thermostatic radiator valves.
■ Close roller shutters (if installed) at dusk.
■ Set thermostatic valves correctly.
■ Never cover radiators or thermostatic valves.
■ Controlled DHW consumption: A shower generally uses less energy than a full bath.
30
Keyword index
Keyword index
C
Cleaning.............................................30
Constant central heating (constant heating mode)...........................................12
Constant heating mode (constant central heating)..............................................12
Control characteristics.......................23
Controls and display elements.............7
Copying a time program...............14, 21
D
Disabling time phases..................14, 21
Display backlighting.............................8
Display symbols...................................7
E
Economy mode....................................7
■ Setting............................................17
■ Terminating.....................................17
F
Frost protection mode........................12
H
Heating mode.....................................10
Holiday...............................................15
Holiday program
■ Scanning.........................................25
■ Setting............................................15
■ Terminating.....................................15
L
Language...........................................22
Lock out controls..................................9
M
Manual mode.....................................12
N
No hot water.......................................26
P
Party mode...........................................7
■ Setting............................................16
■ Terminating.....................................17
Program name...................................22
S
Saving energy..............................15, 30
Scanning time programs....................25
Selecting the operating mode
■ Central heating...............................10
■ DHW heating..................................18
Selecting the time program for DHW heating...............................................18
Setting an individual time program
■ Central heating...............................13
■ DHW heating..................................20
Settings
■ Scanning.........................................25
Setting time phases
■ Central heating...............................13
■ DHW heating..................................20
Standard display..................................8
Symbols on the display........................7
T
Temperature adjustment....................23
Temperatures
■ Change temporarily........................16
■ Changing permanently...................13
■ Scanning.........................................25
Time and date....................................22
Troubleshooting.................................26
Type plate............................................7
W
Wall adjustment.................................23
Water too cold....................................26
31
Applicability
Applies to the Vitotrol 100, type UTDB-RF2
Part no. 7426 467
Your contact
Contact your local contractor if you have any questions regarding the maintenance and repair of your system. You may, for example, find local contractors on the internet under www.viessmann.com.
Viessmann Werke GmbH&Co KG
D-35107 Allendorf
Telephone: +49 6452 70-0
Fax: +49 6452 70-2780 www.viessmann.com
Viessmann Limited
Hortonwood 30, Telford
Shropshire, TF1 7YP, GB
Telephone: +44 1952 675000
Fax: +44 1952 675040
E-mail: [email protected]
32
பதிவிறக்கு
விளம்பரம்