BFT DEIMOS BT KIT UL automatic gate Quick Reference Guide
تبلیغات
تبلیغات
•
Read and follow all instructions and safety procedures.
•
Never let play on or walk in the automatic gate area.
•
Keep all gate controls out of the reach of children.
•
Stand clear of a moving gate and never cross the path of a moving gate.
•
All wiring should only be done by a qualified technician.
•
Always make adjustments and connections with supply power turned “off”.
•
This document does not supersede the full instruction manual included with each product.
TABLE OF CONTENTS
DEIMOS BT Kit Components
Technical specifications
Spare parts
Accessories and replacement parts
Anchoring plate installation
Operator and rack installation
Limit switch brackets installation
Wiring instructions
Battery backup installation
Control board quick programming
Menu flow chart
Wiring diagram
Troubleshooting
Notes
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
......................................
12
13
8
9
5
6
4
4
15
17
18
19
3
3
7
11
14
16
THE DEIMOS BT KITS CONTAIN THE FOLLOWING COMPONENTS
A.
ANCHORING HOOK
B.
HEIGHT ADJUSTMENT PLATE
C.
D.
M10 NUT
E.
POSITIONING TEMPLATE PLATE
M10 WASHER
F.
TRANSMITTER - MITTO 2
G.
PHOTOCELLS - FL 130B
H.
MANUAL RELEASE KEY - CLS
I.
LEFT AND RIGHT LIMIT SWITCH BRACKETS
J.
OPERATOR - DEIMOS BT
1
1
1
1
4
2
1
16
4
1
IIII
Power supply:
Working torque:
Pinion pitch:
Gate travel speed
Limit switches
Manual operation:
Cycles per day:
Gate length:
Gate weight:
120 V ac ± 10% - 60 Hz
14.75 lb ft
0.157” (14 teeth)
7.9 ”/s
Incorporated (electromechanical)
Release key
100 up to 75’ up to1100 lbs
DEIMOS BT SPARE PARTS, ACCESSORIES AND REPLACEMENT PARTS
1
2
5
6
6
7
7
D222262
D221651
I098401
I098401
I098421
I098401
I098421
8
8
9
9
I098401
I098421
I098401
I098421
10 I098401
10 I098421
11 I098401
11 I098421
12 I098404
12 I098501
13 I098404
13 I098425
13 I098501
14 I098404
15 I098404
16 I101100
17 I101100
18 I098512
18 I101100
19 I101100
20 I101100
21 I101100
22 I101100
23 I101100
24 I101100
Item
•
OPERATOR - DEIMOS BT
•
CONTROL BOARD - QSCD UL
•
TRANSMITTER - MITTO 2
•
PHOTOCELLS - FL 130B
•
MANUAL RELEASE KEY - CLS
•
ANCHORING SYSTEM FOR DEIMOS BT
25 I101100
26 I101100
27 I098417
28 I098416
29 I098416
30 I101108
32 D511286
34 I098417
34 I101103
36 I098404
36 I098417
37 I098417
40 I098416
41 I098416
42 I098416
43 I098416
P925186 00002
D111754 00001
D111750
P111043 00001
D610180
N999359
44 I098416
45 I101102
46 I101102
47 I101102
48 I101102
49 I101102
50 I101102
51 I101102
52 I101103
53 I101108
54 I101103
55 I101103
56 I101108
58 D110941 00002
59 D221520
64 D221463
65 D511272
66 I098401
66 I101109
68 D111754 00001
69 D221826
72 D511318
73 D141382
74 I101108
75 D511184
76 I101102
77 I098417
78 I098417
79 D802089
80 D221464
62 D221827 81 I098401
OPTIONAL ACCESSORIES
81 I101109
82 I098401
82 I101109
91 I101111
91 I098401
91 I098421
91 I101112
121 I098416
122 I098416
123 I098416
124 I098416
125 I098416
126 I098416
Item
•
DIGITAL KEYPAD (external)- SELETTO E P121013
•
DIGITAL KEYPAD (flush)- SELETTO
•
INTERFACE FOR SELETTO - SCS1
P121012
P111376
•
STEEL REINFORCED PLASTIC RACK (3’3”) - CP D221073
•
STEEL ADJUSTABLE RACK (3’3”) - CVZ
•
STEEL HEAVY DUTY RACK (6’6”) - CVZ
•
18 TEETH PINION (10.5 ”/s gate speed)
D571053
D571054
I098425
•
PERSONALISED KEY RELEASED KNOB - MSC N999158
•
RECEIVER ANTENNA - AEL 433 D113632
•
24 Vdc BATTERY BACKUP P125002
ANCHORING PLATE INSTALLATION
•
Inspect all components of the gate to insure proper manual operation and smooth sliding.
•
Gate must slide freely and smoothly throughout its travel.
•
Make sure that mechanical stops preventing the gate from slipping off the upper guide when manually operated are present and sound enough.
•
The gate track must be horizontal and straight. Non straight track will not allow proper operation of pinion and rack.
Never install the rack prior to installation of the operator, installing the rack before the operator will not allow proper mesh of pinion and rack.
Rack: CP -> T = 1.57”
The operator has to be installed at the opening post edge.
CVZ -> T = 1.45”
•
Dig a hole for the concrete pad.
•
(D) plate must be positioned all the way down to the thread of the hooks.
•
Measurements for the positioning of the template plate are shown in Fig. 1. It is required at this stage to take into consideration the thickness of the rack as it is important to position the template plate so that
T 0.9” rack-template plate distance is 0.9” (rack not installed yet
at the moment). For CP rack T measure is 1.57”, for CVZ rack T measure is 1.45”.
FIG.
1
•
Position the template plate in the hole, make sure it is level. The template plate must have the pinion engraving next to the gate. In case the hole can be executed under the track, it is suggested to weld two steel bars across the anchoring hooks and the track of the gate as shown in Fig. 2, so that if the track sags, the concrete pad will sag too, keeping the play between pinion and rack constant over time.
•
Remember that cable conduits have to pass through the hole in the template plate. Pour concrete. can be carried out simply drilling holes in the concrete pad using the template plate as reference and anchoring the operator using chemical anchors and threaded bars instead of anchoring hooks (chemical anchors, threaded bars and nuts not provided).
OPERATOR AND RACK INSTALLATION
STEP 2
•
Position provided nuts (D)
This clearance is very important, in case the V-tracks sags, having no clearance prevents any future adjustment, the pinion will bear part of the weight of the gate, leading to wear of the rack and pinion teeth and possible damage to pinion shaft and bearings.
•
Level height adjustment plates using the 4 lower nuts
•
Remove the cover of the operator (A) the two height adjustment plates. Slide it into its final operating position (pinion close to the gate).
•
Use provided nuts (D)
•
Disengage the gate by turning the release knob clockwise until a “click” is heard.
CP – STEEL REINFORCED PLASTIC
RACK
1.
Start with gate in closed position.
2.
Put one end of rack section on the sprocket.
Make it level and mark on the gate the center of the slot (Fig. 4).
3.
Manually slide the gate so that the mark on the gate is reachable. Drill a hole on the gate and connect the rack to the gate using a self tapping screw (not provided). Make sure that the screw is centered in the slot for future adjustment.
4.
Put the rack on the pinion and slide the gate so that the other end of the rack section is on the pinion, mark the center of the slot on the gate
(Fig. 5).
5.
Manually slide the gate, drill a hole on the mark and connect the second end of the rack to the gate using a self tapping screw (not provided).
6.
The first section of the rack is positioned, use a third screw to secure the section (on a section at least 3 screws have to be used).
Mark and bolt
FIG. 4
Mark and bolt
OPERATOR AND RACK INSTALLATION
7.
Repeat steps from 2 to 6 to position other sections of the rack until proper length is reached.
8.
It is suggested to use an additional section of the rack clamped on the section which is already connected to the gate and on the section to be connected to grant proper teeth pitch between different section (Fig. 6).
9.
If needed, cut the last section to meet gate length. approx. on each side).
10.
Lower the operator using nuts so that the play between rack and pinion is between 1 and 2 mm (1/16”) throughout the whole length of the gate (Fig. 7).
11.
Check that the gate runs smoothly throughout its whole length. Check that the play between rack and pinion is optimal throughout the whole length of the gate.
12.
Check that the mesh of pinion and rack is correct
(Fig. 8), the rack teeth must engage the pinion teeth throughout their full thickness. If not, adjust the position of the operator by sliding it in required direction.
13.
If needed, position of the rack can be adjusted for each section changing the position of the screws in the slots.
C VZ
GALVANIZED STEEL ADJUSTABLE RACK
Install provided bolts, rack nuts and washers on each section of the rack.
Take care to tighten bolt and nuts at the center of each slot for possible future adjustment.
Proceed then the same way as CP rack for installation. Instead of bolting the rack on the gate, rack nuts have to be welded on the gate (Fig. 9).
In order to be able to rotate the rack, simply loosen the rack bolts. travel of the gate to accommodate limit switch
LIMIT SWITCH BRACKETS INSTALLATION
STEP
3
•
Position the limit switch will stop at the desired position
(the operator stops when the limit switch spring is pushed by generally positioned at he two ends of the rack.
•
Inertia will drive the gate a little further. At least 1” between the gate and the positive stop has to be granted (Fig. 11). Not providing this clearance will result in possible jamming of sliding gate never
•
If no positive stops are present they have to be installed on both sides.
FIG. 10
FIG. 11
WIRING INSTRUCTIONS
•
Connect the line wire termi nal
•
Connect the neutral wire terminal
33 of the Deimos BT control board.
•
Connect the ground wire spade connector is needed, stripped wire is fine.
Wire not supplied neutral (white) line (black) ground (green)
•
Connect the antenna cable to Deimos BT circuit board. Strip cable and connect the core wire to terminal 10 and the shield wire to terminal 11.
CONNECTI
NG THE PHOTOEYE (THROUGH BEAM)
•
Connect #1 & #2 of the photoeye receiver to the terminal 13 & 12 of the
Deimos BT control board.
•
Connect #3 & #5 of the photoeye receiver to the terminal 21 & 24 of the
Deimos BT control board.
Remove jumper wire on terminals 21-24.
Wires not supplied.
WIRING INSTRUCTIONS
•
Connect #1 & #2 of the photocell transmitter to the terminal 13 & 12 of the Deimos BT control board.
Wires not supplied.
•
Note: on BFT control boards safety contacts are always N.C., multiple safety devices connected to the same contact have to be connected in series.
Command contacts are always N.O., multiple command devices connected to the same contact have to be connected in parallel.
All command and safety contacts are dry contacts, giving tension to these contacts will damage the board.
•
In case more than one photoeye is required, photoeyes have to be connected in series (NC contact). Follow the diagram (install receivers to avoid cross talking):
BFT Photoeye
Receiver 1
BFT Photoeye
Transmitter 1
BFT Photeye
Receiver 2
BFT Photoeye
Transmitter 2
•
Safety loops detectors have to be connected as photoeyes, as they use the same PHOT contact (21
– 24). Every device connected to PHOT contact, including the safety loops, has to be a N.C. contact and will be connected in series.
WIRING INSTRUCTIONS
CONNECTING OTHER ACCES
SORIES:
•
Accessories such as telephone entry systems and free exit loops will be connected to the OPEN contact (21 – 26). Every device connected to OPEN contact has to be a N.O. contact and will be connected in parallel.
•
Accessories such as Single Button Control or external receiver contact will be connected to the
START contact (21 – 22).
The button will command the gate to:
OPEN/STOP/CLOSE in sequence (3 step logic ON)
OPEN/STOP/CLOSE/STOP in sequence (3 step logic OFF)
For further details on programming the control board, refer to “Finalizing the installation” chapter at page 13.
Note: START-CLOSE logic has to be set to OFF for the Single Button Control to work correctly.
For further details on programming the control board, refer to “Finalizing the installation” chapter at page 13.
The operator con be installed on the left side or on the right side of the drive way (depending on the sliding gate). In order to right direction of movement of the gate, proceed with the following steps:
•
Turn power off and disengage the operator.
•
Put the gate halfway open.
•
Re-engage the operator and turn power on.
•
Give a START command (a momentary jumper of terminals 21 – 22).
•
Turn the power off.
•
Reverse the connection of the motor and the limit switches: swap terminals 1 and 2 swap terminals 6 and 7.
Blue (-)
Red (+)
Black (COM)
Red (SWC)
Brown (SWO)
The operator is ready to be programmed.
Red (-)
Blue (+)
Black (COM)
Brown (SWC)
Red (SWO)
No further steps are required and the operator is ready to be programmed.
BATTERY BACKUP INSTALLATION
•
Unplug the power.
•
Place batteries (a shown in Fig. 12. Cut a hole in the black rubber cap
•
Run battery wire (++ red and -- black) into the provided black sheath. Disconnect wire on terminal
4 on the Deimos BT control board and run it through the hole. Run through the hole provided wires
(marked 55, 33, ++ and --).
•
Connect wires as illustrated below
Note: wires going to terminal 3 on the board can be crimped together using provided ferrule):
Battery jumper
FIG. 12
SBS
•
(c) terminal 4 on the Deimos BT board to terminal 4 on the SBS charger. Connect wire labeled ++ to
#1 on the SBS charger, wire labeled -- to #2 on the SBS charger, wire labeled 33 to #3 on the SBS charger and to #3 on the Deimos BT board, wire labeled 55 on #5 on the SBS charger and on #4 on the Deimos BT board.
•
Secure the SBS charger below the board by using provided screw.
•
Connect remaining red wire with spades (battery jumper) to free negative and positive pole on the batteries.
•
Check that polarity is respected with photocells and accessory power supply:
When in battery mode #13 is + (positive), #12 is – (negative).
2
1
((((----))))
•
On BFT photocells #1 is + (positive), #2 is – (negative):
•
Check other accessories polarity according to the manufacturer’s installation manual.
((((----))))
12
13
5
4
3
2
1
((((----))))
(+)
CONTROL BOARD QUICK PROGRAMMING
+ BUTTON
- BUTTON
OK BUTTON
•
The “OK entering the menus.
•
The “+ increasing values.
•
The “----” button is used for: scrolling down the menus (go down in the menus as shown at page 15), decreasing values.
•
The “+ discarding changes to programming, exiting from the programming mode (turning off the display).
•
Turn the power off to the control board.
•
Connect any external control device according to wiring diagram on page 17.
•
Turn on power to control board. Check red power light on Deimos BT control board.
1.
Turn on the display (by pressing twice the “OK
2.
Scroll down (“----“ button) to “Radio
3.
The display will show “Add Start
4.
The display will show “Hidden button transmitter you want to store as shown in Fig. 13.
5.
The display will show “Desired button the gate with as shown in Fig. 14.
6.
The display will show “Add Start other transmitters.
7.
+
FIG. 13
FIG. 14
CONTROL BOARD QUICK PROGRAMMING
S ETTING THE FORCE
1.
Turn on the display (by pressing twice the “OK
2.
Scroll down (“----“ button) to “Autoset
The autoset feature will automatically let the control board learn torques required to correctly operate the gate.
WARNING :
Once “OK” button is pressed the gate will start to move, obstruction detection is disabled during Autoset. Be sure that no obstacle is within the working range of the gate while
Autoset is being performed.
NOTE :
the Autoset must be launched from a fully closed position. Autoset run from a different position may lead to improper control board setting.
3.
Press “OK
4.
At the end of the second cycle the display will show “OK heavy gate).
5.
Turn off the display.
Timer to close (sec....))))....
Normal opening speed time Working time (sec) at full speed a fter this time motor will
Working time (sec) at full speed during closing, a fter this time motor will proceed
Slow down speed :
WARNING!
after changing the abo
C ommands during opening ignored (ON)
MENU FLOW CHART
PARAMETER MENU
TCA (timer to close) [sec.]
(default 10 sec., min 3 sec., max 60 sec.)
Opening torque [%]
(default 80%, min 1%, max 99%)
Closing torque [%]
(default 80%. min 1%, max 99%)
Opening torque slow-down [%]
(default 50%, min 1%, max 99%)
Closing torque slow-down [%]
(default 50%, min 1%, max 99%)
Normal opening speed time [sec.]
(default 15 sec., min 1sec., max 120 sec.)
Normal opening speed time [sec.]
(default 15 sec., min 1sec., max 120 sec.)
SIow-down speed
0= SIow-down disabled
1 = 50% of normal speed
2= 33% of normal speed
3= 25% of normal speed
Zone (serial connection – requires SCS1 card)
(default 0, min 0, max 127)
Default: OFF, Enabled: ON, Disabled: OFF
3 ST EP
Default: OFF, 3 step: ON, 4 step: OFF
Default: OFF, Enabled: ON, Disabled: OFF
Default: OFF, Enabled: ON, Disabled: OFF instruction manual for further details)
Default: OFF, Enabled: ON, Disabled: OFF
Default: OFF, Enabled: ON, Disabled: OFF
Default: OFF, Single op. install.: ON, Dual op. inst.: OFF
Default: OFF, Term. 16: CLOSE: ON, Term. 16 START: OFF
Default: ON, Fixed code: ON, Rolling code: OFF
RADIO PROG. (radio Iearn)
Default: ON, Enabled: ON, Disabled: OFF
Default: OFF, Enabled: ON, Disabled: OFF
Default: OFF, Master board: ON, Slave board: OFF
MENU FLOW CHART
(Program a button of a remote to activate the gate)
(No effect)
(Check if a remote is I the memory of the receiver and display button #)
EX:
02 t1 (remote #2, button #1) ko (remote not in the memory)
ERASE 64
Removes all remotes devices from the receiver memory.
Displays the receiver code
(required only if cloning remotes is needed)
It automatically sets the motor torque (Motor 1 torque, Motor 2 torque, Motor 1 slow down torque, Motor 2 slow down torque).
Note:
If slow down is disabled or not reached slow down torque will not be set. After slow down adjustment Autoset has to be carried out gain.
WARNING!: obstruction detection is disabled during Autoset. Be sure that no obstacle is within the working range of the gate while Autoset is being performed.
Transformer connection
M
BLUE
RED
WIRING DIAGRAM
)
MOTOR CONNECTION
NC
NC
COM
SWC
SWO
24 Vdc/25 W max
ANTENNA
SHIELD
24 Vac OUT (180 mA max) while the alarm is active the gate is stopped. Reset the control board before reactivating the gate.
Acoustic signal contact N.O.
24 Vac Vsafe OUT (180 mA max)
NO
NO
NO
NC
NC
NC
NO
FAULT
COM
PED
COM
START
STOP
PHOT
BAR
OPEN
BLACK
RED
BROWN
)
STROBE LIGHT CONNECTION
)
ANTENNA CONNECTION
)
24 Vac power supply to accessories
)
UL ALARM: the contact closes after 2 consecutive obstruction detections with no limit switch activation. Can be reset by opening the stop contact or switching off the power supply.
)
24 Vac power supply to fail safe accessories
(requires different wiring ––
PHOTOEYE SELF TEST TERMINAL: failure check terminal for PHOTOEYE terminal
(requires different wiring
––
see instr. manual for details))))
COMMON TEMINAL
PARTIAL OPENING TERMINAL: opens the gate for 3’
COMMON TEMINAL
START/CLOSE TEMINAL: opens-closes-stops (START) or always closes
(CLOSE) the gate depending on the logic setting (default is START)
STOP & RESET TERMINAL: stops the gate and UL ALARM when opened
PHOTOEYE TERMINAL: stops the gate when opened, when closed back continues opening (if gate opening) or reverses (if gate closing)
SAFETY EDGE TERMINAL: stops, reverses and halts the gate when engaged. Further command needed to move the gate.
OPEN TERMINAL: opens the gate when closed (eg. Free exit or telephone entry contact)
Transformer connection
120 V ac power input
NEUTRAL (WHITE)
LINE (BLACK)
FAULT
The red LED on the board is
OFF
OPERATOR DOES NOT RUN remote or single button control (terminal 21-22) not
OPERATOR DOES NOT RUN
GATE OPENS BUT DOESN’T
CLOSE
GATE STOPS AND
REVERSES AFTER
STARTING TO MOVE
GATE DOES NOT CLOSE
AUTOMATICALLY
GATE RUNS TOO SLOW
GATE DOES NOT SLOW
DOWN
STOP
PHOT
DIAGNOSTIC
TROUBLESHOOTING
POSSIBLE CAUSE
Display blank and STRT displayed when hitting the button
STRT not displayed when hitting the button
STRT displayed when giving the command
OPEN
PHOT
AMP or BAR displayed when starting reversing
FIX
Power or transformer connection is loose. Check power and transformer connections.
Main fuse (next to 120 Vac input) is blown. Replace fuse.
Bad control board. Replace control board.
STOP contact is open (21 – 23).
PHOT contact is open (21 – 24).
UL ALARM activated (14 – 15 contact closed).
Remote not programmed.
Check STOP contact connections.
Check PHOT connections or photoeye obstructed. Check proper functioning of connected devices.
Reset the board (open and close STOP contact (2123) or switch off and back on the power.
Program remote (see remote programming at page 13).
Replace battery. Remote battery out of charge (LED off on the remote when pressing button).
Motor fuse blown.
Bad control board.
Replace fuse
Replace control board.
Gearbox jammed
Bad control board.
Bad motor.
OPEN contact (21-26) continuously closed
(ex. open button stuck).
PHOT contact is open (21 – 24). The gate opens because photoeye is ignored on opening in the logic setting.
Torque setting too low.
Obstruction present.
Disengage the operator. Move it manually. Re-engage the operator.
Check limit switch brackets adjustment to avoid further jamming.
Replace control board.
Replace motor.
Open the OPEN contact.
Check PHOT connections or photoeye obstructed. Check proper functioning of connected devices.
Increase manually the torque (Motor 1 torque, Motor 2 torque, Motor 1 torque slow-down, Motor 2 torque slow-down in parameters section) or un another
Autoset.
Remove obstructions.
OPEN
Automatic closing is disabled. Set automatic closing (TCA in logics section) to ON.
Open the OPEN contact.
PHOT
OPEN contact (21-26) continuously closed
(ex. open button stuck).
PHOT contact is open (21 – 26). The gate opens because photoeye is ignored on opening in the logic setting.
Working time at normal speed is set too low.
Slow down is disabled.
Working time at normal speed is higher than the time required to get to the full opening/closing position.
Check PHOT connections or photoeye obstructed. Check proper functioning of connected devices.
Increase working time at normal speed
(Normal opening and closing speed time parameters section) to desired value.
Activate slow down (SIow-down speed in parameters section).
Decrease working time at normal speed (Normal opening and closing speed time parameters section) to desired value.
NOTES
DEIMOS BT QUICK REFERENCE GUIDE v 1.0 - 10/07/2007
•
UL 325 approved by CSA
•
Rack and pinion drive for smooth gate movement
•
LCD display programming for maximum installation speed and flexibility
•
Exhaustive diagnostic messages by the display
•
Built-in rolling code receiver
•
Very compact design, control board and battery back up fit in the operator
•
Very energy efficient motor at only 70 W (3 amps)
•
Autoset feature to quickly and simply adjust torque level on the gate
•
Opening width up to 75’
•
Adjustable slow down, 3 different slowdown speeds
•
Battery backup available, batteries are engaged only when main power is out
•
Easy manual release through triangular key
•
Inherent obstruction detection system for maximum safety
Also available from BFT
Road barriers
20
Hydraulic underground operators
Hydraulic arm operators Electromechanical arm operators
Technical Support: 1-877-995-8155
Accessories