Black Box MT1200 A, A -DC, MT1201 A, A -DC, MT1207 A, A -DC Voice Trunking Gateway Installation and Operation Manual
विज्ञापन
विज्ञापन
JULY 2004
MT1200A MT1200A -DC
MT1201A MT1201A -DC
MT1207A MT1207A -DC
Voice Trunking Gateways
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
Contents
Chapter 1. Introduction
1.1
Overview.....................................................................................................................
1-1
Versions................................................................................................................................
1-1
Applications..........................................................................................................................
1-2
Features................................................................................................................................
1-3
1.2
Physical Description.....................................................................................................
1-5
1.3
Functional Description.................................................................................................
1-7
Voice Interface .....................................................................................................................
1-7
Ethernet Main Link (ETH NET Port) .....................................................................................
1-11
Serial Main Link..................................................................................................................
1-11
Ethernet User LAN (ETH USER Port)....................................................................................
1-12
Bandwidth Utilization when using TDMoIP .........................................................................
1-12
Bandwidth Utilization when using MPLS .............................................................................
1-13
1.4
Technical Specifications.............................................................................................
1-15
Chapter 2. Installation and Setup
2.1
Site Requirements and Prerequisites ............................................................................
2-1
2.2
Package Contents ........................................................................................................
2-2
2.3
Installation and Setup ..................................................................................................
2-2
Setting the E1 Voice Port Internal Jumpers (MT120 xAE) ........................................................
2-2
Connecting the Interfaces .....................................................................................................
2-4
Connecting the Power ..........................................................................................................
2-6
2.4
Installing MT120xA in a 19-Inch Rack..........................................................................
2-7
Rack-Mount Kit Contents ......................................................................................................
2-7
Equipment Needed ..............................................................................................................
2-7
Installation............................................................................................................................
2-8
Chapter 3. Operation
3.1
Front Panel Indicators ..................................................................................................
3-1
3.2
Operating MT120xA....................................................................................................
3-2
Turning On MT120xA...........................................................................................................
3-2
Normal Indications ...............................................................................................................
3-2
Turning Off MT120xA...........................................................................................................
3-2
3.3
Default Settings............................................................................................................
3-2
Chapter 4. Management from a Terminal
4.1
Preparing for the Control Session .................................................................................
4-1
Control Port Interface Characteristics.....................................................................................
4-1
Preparing the Terminal..........................................................................................................
4-1
Levels of Security ..................................................................................................................
4-2
4.2
Navigating the Management Menus.............................................................................
4-3
Choosing Parameters ............................................................................................................
4-3
Saving and Aborting Configuration Changes ..........................................................................
4-3
4.3
Starting the Control Session .........................................................................................
4-4
4.4
Displaying the MT120xA Inventory..............................................................................
4-5
MT120xA Installation and Operation Manual i
Table of Contents
4.5
Configuring the MT120xA System................................................................................
4-6
Configuring the Control Port .................................................................................................
4-7
Configuring the Ethernet Management Connection ...............................................................
4-8
Configuring Telnet Access ...................................................................................................
4-11
Managing the User Database ..............................................................................................
4-11
Setting the Date and Time ..................................................................................................
4-15
Assigning a Name to the MT120xA Unit..............................................................................
4-16
4.6
Configuring Signaling Information ..............................................................................
4-16
Configuring Signaling Profiles ..............................................................................................
4-16
Configuring Keep-Alive Suppression Rate ............................................................................
4-19
4.7
Configuring the Main Links ........................................................................................
4-20
Choosing the Main Link Interface........................................................................................
4-20
Configuring the Main Link...................................................................................................
4-21
4.8
Configuring the Voice Ports .......................................................................................
4-24
Configuring Bundles............................................................................................................
4-24
4.9
Configuring the User Ethernet Port.............................................................................
4-45
4.10
Restoring Default Settings ..........................................................................................
4-45
4.11
Resetting the MT120xA .............................................................................................
4-45
Chapter 5. Configuring a Typical Application
5.1
Application Requirements............................................................................................
5-1
5.2
Outline of Configuration Procedure .............................................................................
5-2
5.3
Configuring the Local Voice Mux Gateway ..................................................................
5-2
5.4
Configuring MT120xA for Operation with CAS Signaling..............................................
5-3
Configuring System Parameters .............................................................................................
5-3
Configuring Voice E1 Parameters ..........................................................................................
5-4
Transferring Database to the Second MT120xA .....................................................................
5-5
5.5
Configuring MT120xA for Operation with CCS Signaling..............................................
5-5
Chapter 6. Diagnostics
6.1
Tone Injection .............................................................................................................
6-1
6.2
Loopback Tests............................................................................................................
6-3
Local Loopback ....................................................................................................................
6-3
Remote Loopback.................................................................................................................
6-4
6.3
Pinging Remote Devices ..............................................................................................
6-5
6.4
Displaying the Active Tests...........................................................................................
6-5
Chapter 7. Monitoring and Statistics Collection
7.1
Alarms .........................................................................................................................
7-1
Alarm Buffer .........................................................................................................................
7-1
Working with the Temporary Alarm Buffer ............................................................................
7-1
Working with the Permanent Buffer ......................................................................................
7-3
List of MT120xA Alarms........................................................................................................
7-4
7.2
Sanity Checks ..............................................................................................................
7-5
Displaying the Sanity Errors and Warnings.............................................................................
7-6
List of Sanity Errors and Warnings..........................................................................................
7-7
7.3
Collecting Statistics ......................................................................................................
7-8
Displaying Bundle Statistics ...................................................................................................
7-9
Displaying Timeslot Voice Statistics .....................................................................................
7-12 ii MT120xA Installation and Operation Manual
Table of Contents
Displaying the Voice Signaling Statistics (MT1200A, MT1207A, MT120 xAE) ........................
7-14
Displaying the FXS Signaling Statistics (MT1201A only) ........................................................
7-15
Displaying HDLC Statistics ..................................................................................................
7-16
Displaying the Serial Port Statistics.......................................................................................
7-17
Displaying the Ethernet Statistics .........................................................................................
7-20
Chapter A. Interface Connector Specifications
A.1
Voice Ports .................................................................................................................. A-1
T1/E1 Interface Connector (MT1200A, MT1207A, MT120 xAE only)......................................A-1
FXS Interface Connectors (MT1201A only) ............................................................................A-1
A.2
Ethernet Interface Connectors...................................................................................... A-2
A.3
Serial Port....................................................................................................................A-3
Serial Port Connector............................................................................................................A-3
RS-530/DTE Interface Adapter Cable.....................................................................................A-5
V.35/DCE Interface Adapter Cable ........................................................................................A-6
V.35/DTE Interface Adapter Cable ........................................................................................A-7
X.21/DCE Interface Adapter Cable ........................................................................................A-8
X.21/DTE Interface Adapter Cable.........................................................................................A-9
A.4
CONTROL Connector ................................................................................................. A-9
Chapter B. Boot Manager and Software Downloading
B.1
Introduction................................................................................................................. B-1
B.2
Booting MT120xA ....................................................................................................... B-1
Boot Sequence .....................................................................................................................B-1
Accessing the File System......................................................................................................B-2
B.3
Downloading the Application and Configuration Software ........................................... B-3
Downloading Application Files via XMODEM........................................................................B-3
Downloading Application Files using the TFTP Server ............................................................B-4
Downloading Application Files using the TFTP Client ............................................................B-5
Uploading/Downloading Configuration Files using the TFTP Client ........................................B-5
Chapter C. Configuration Menus
MT120xA Installation and Operation Manual iii
Table of Contents
List of Figures
1-1. Transmitting LAN Data and Compressed Digital/Analog Voice in Point-to-Multipoint Application
...............................................................................................................................................
1-2
1-2. Data and Compressed Digital/Analog Voice over Satellite Link ..............................................
1-2
1-3. MT120xA, 3D View ..............................................................................................................
1-5
1-4. Rear Panel of MT1200A/MT1207A........................................................................................
1-6
1-5. MT120xA Block Diagram ......................................................................................................
1-7
1-6. TDMoIP Frame Structure.......................................................................................................
1-8
1-7. Ethernet Frame Structure.......................................................................................................
1-9
1-8. VLAN Tag Format................................................................................................................
1-11
2-1. MT120 xAE E1 Jumper Locations .........................................................................................
2-3
2-2. MT120e1A Rear Panel (E1 Voice Port and AC Power Supply)................................................
2-4
2-3. MT1200/MT1207A-DC Rear Panel (T1 Voice Port and DC Power Supply) ............................
2-5
2-4. MT1201A Rear Panel (FXS Voice Ports and AC Power Supply) ..............................................
2-5
2-5. Bracket Assembly for Installing a Single MT120xA Unit in a 19-inch Rack..............................
2-8
2-6. Bracket Assembly for Installing Two MT120xA Units Side by Side in a 19-inch Rack.............
2-9
3-1. MT120xA, Front Panel ..........................................................................................................
3-1
4-1. Password Request Screen ......................................................................................................
4-4
4-2. Main Menu ...........................................................................................................................
4-4
4-3. Inventory Screen for MT120xA..............................................................................................
4-5
4-4. Configuration Menu (MT1200A/MT1207) .............................................................................
4-6
4-5. System Menu ........................................................................................................................
4-7
4-6. Control Port Menu ................................................................................................................
4-8
4-7. Management Menu...............................................................................................................
4-9
4-8. Host IP Menu ........................................................................................................................
4-9
4-9. Manager List Menu..............................................................................................................
4-10
4-10. Telnet Menu......................................................................................................................
4-11
4-11. User Administration Menu.................................................................................................
4-12
4-12. Add New User Menu ........................................................................................................
4-12
4-13. Delete User Menu.............................................................................................................
4-13
4-14. Change User Details Menu................................................................................................
4-14
4-15. Show All Users Screen.......................................................................................................
4-15
4-16. Date & Time Update Menu...............................................................................................
4-15
4-17. Signaling Configuration Menu............................................................................................
4-17
4-18. Signaling Profile Configuration Menu.................................................................................
4-17
4-19. Signaling Table Configuration Screen.................................................................................
4-18
4-20. SS7 Keep-Alive Suppression Rate Menu.............................................................................
4-20
4-21. Switch Lan Configuration Menu ........................................................................................
4-21
4-22. Network Port Parameters Menu ........................................................................................
4-22
4-23. Serial Port Configuration Menu..........................................................................................
4-23
4-24. Voice Configuration Menu ................................................................................................
4-25
4-25. Bundles Parameters Menu.................................................................................................
4-25
4-26. Bundle Configuration Menu ..............................................................................................
4-26
4-27. Configuration Menu for MT1201A ....................................................................................
4-26
4-28. FXS Configuration Menu....................................................................................................
4-27 iv MT120xA Installation and Operation Manual
Table of Contents
4-29. Edit Bundle Menu for MT120xA with T1/E1 Port ...............................................................
4-27
4-30. Connectivity Parameters Menu..........................................................................................
4-28
4-31. TOS Parameters Menu ......................................................................................................
4-29
4-32. Voice Parameters Menu for T1/E1 Port ..............................................................................
4-30
4-33. VLAN Parameters Menu ....................................................................................................
4-31
4-34. Edit Bundle Menu for MT1201A........................................................................................
4-32
4-35. Voice Parameters Menu for FXS Port (MT1201A)...............................................................
4-34
4-36. T1 Parameters Menu .........................................................................................................
4-35
4-37. Distribution Of Framer Time Slots Menu ...........................................................................
4-37
4-38. Configure Time Slots Menu ...............................................................................................
4-37
4-39. Display Time Slots Configuration Screen............................................................................
4-39
4-40. E1 Parameters Menu .........................................................................................................
4-39
4-41. Timeouts Menu .................................................................................................................
4-41
4-42. Ringer Profile menu...........................................................................................................
4-42
4-43. Port Configuration Menu...................................................................................................
4-43
4-44. FXS Signaling Parameters Screen........................................................................................
4-44
4-45. Ports Distribution Menu ....................................................................................................
4-44
5-1. Typical Application................................................................................................................
5-1
5-2. E1 Bundle and Timeslot Configuration...................................................................................
5-5
6-1. Local Tone Injection..............................................................................................................
6-1
6-2. Diagnostics Menu..................................................................................................................
6-2
6-3. Inject Tone Menu..................................................................................................................
6-2
6-4. Local Loopback .....................................................................................................................
6-3
6-5. Local Loop Test Menu ...........................................................................................................
6-4
6-6. Remote Loopback .................................................................................................................
6-4
6-7. Ping Menu.............................................................................................................................
6-5
7-1. Monitoring Menu ..................................................................................................................
7-2
7-2. Status Menu ..........................................................................................................................
7-2
7-3. Display Menu........................................................................................................................
7-3
7-4. Temporary Alarms Buffer (Display All Alarms Screen).............................................................
7-3
7-5. Permanent Buffer (Alarm Status Screen).................................................................................
7-4
7-6. Display Sanity Menu..............................................................................................................
7-6
7-7. Statistics Menu ......................................................................................................................
7-8
7-8. Bundles Statistics Menu .........................................................................................................
7-9
7-9. Mode Menu ........................................................................................................................
7-10
7-10. Bundle Statistics ................................................................................................................
7-10
7-11. Voice Statistics Menu.........................................................................................................
7-12
7-12. Timeslot Voice Statistics Screen .........................................................................................
7-13
7-13. Voice Rx Signaling Statistics ...............................................................................................
7-14
7-14. Voice Tx Signaling Statistics ...............................................................................................
7-15
7-15. FXS Signaling Statistics Screen............................................................................................
7-15
7-16. HDLC Statistics Screen ......................................................................................................
7-16
7-17. Serial Port Statistics Menu..................................................................................................
7-18
7-18. Serial Port Statistics Screen ................................................................................................
7-18
7-19. Ethernet Statistics Menu ....................................................................................................
7-20
7-20. Ethernet Statistics Screen ...................................................................................................
7-21
MT120xA Installation and Operation Manual v
Table of Contents
A-1. RJ-45 Connector Pin Location ............................................................................................... A-1
A-2. RJ-11 Connector Pin Location ............................................................................................... A-1
B-1. File System Menu.................................................................................................................. B-2
C-1. MT120xA Menu Tree, Inventory and Configuration Menus...................................................C-1
C-2. Voice Configuration Menus for E1 and T1 Voice Ports...........................................................C-2
C-3. FXS Configuration Menus for FXS Voice Ports........................................................................C-3
C-4. User Administration Menus...................................................................................................C-4
C-5. Monitoring and Diagnostics Menus .......................................................................................C-5
List of Tables
1-1. Ethernet Frame Fields..........................................................................................................
1-10
1-2. UDP Source Port as Destination Voice Port .........................................................................
1-11
2-1. MT120 xAE E1 Jumper Settings ............................................................................................
2-4
3-1. MT120xA LEDs .....................................................................................................................
3-1
3-2. MT120xA Indicator Status .....................................................................................................
3-2
3-3. MT120xA Default Settings .....................................................................................................
3-2
4-1. Signaling Bits Configuration .................................................................................................
4-19
7-1. MT120xA Alarms...................................................................................................................
7-4
7-2. Sanity Errors and Warnings ....................................................................................................
7-7
7-3. Bundle Statistics Values for Voice Port .................................................................................
7-11
7-4. Timeslot Voice Statistics Values............................................................................................
7-13
7-5. HDLC Statistics Values.........................................................................................................
7-17
7-6. Serial Port Statistics Values...................................................................................................
7-19
7-7. Ethernet Statistics Values .....................................................................................................
7-21
A-1. T1/E1 RJ-45 Connector Pinout .............................................................................................. A-1
A-2. FXS Connector Pinout ........................................................................................................... A-1
A-3. Ethernet Connector Pinout.................................................................................................... A-2
A-4. DB-25 Serial Port Connector Pin Assignment......................................................................... A-3
A-5. Serial Interfaces supported by MT120xA ............................................................................... A-4
A-6. MT1205 Interface Cable Pin Assignment ............................................................................... A-5
A-7. MT1203 Interface Cable Pin Assignment ............................................................................... A-6
A-8. MT1204 Interface Cable Pin Assignment ............................................................................... A-7
A-9. X.21/DCE Interface Cable Pin Assignment ............................................................................. A-8
A-10. X.21/DTE Interface Cable Pin Assignment............................................................................ A-9
A-11. CBL-RJ45/D9/F/STR Cable Pin Assignment .......................................................................... A-9 vi MT120xA Installation and Operation Manual
Chapter 1
Introduction
1.1 Overview
MT1200A, MT1201A and MT1207A are voice trunking gateway units that enable digital T1/E1 or analog voice channels to be compressed and extended over an IP or serial link. These units implement G.723.1, G.729 A, G.711 compression and
TDMoIP or MPLS multiplexing algorithms to send up to 30/24 digital or four analog voice channels over an IP or n x 64 kbps network, with transparent CAS and CCS support.
MT1200A, MT1201A and MT1207A units utilize voice activity detection, silence suppression, echo cancellation and other techniques to improve voice quality. The gateways detects, generates and relays DTMF/MFR2/MFC signaling. In addition, they support fax relay and voice band data.
The units can be managed locally via an ASCII terminal or remotely via Telnet or
SNMP-based network management applications.
Versions
Note
The following voice trunking gateway unit models are available:
• MT1200A provides a single T1 port that can support up to 6 digital voice channels
• MT1201A provides FXS ports to support up to 4 analog voice channels
• MT1207A provides a single T1 port that can support up to 24 digital voice channels
• MT120 xAE provides a single E1 port that can support up to 30 digital voice channels.
All the above models are also available in DC-powered versions
In this manual, the generic term MT120xA is used when the information is applicable to all equipment versions. The complete equipment designation is used only for information applicable to specific equipment versions.
Overview 1-1
Chapter 1 Introduction
Applications
shows a central voice mux gateway operating opposite MT120xA units
and another remote voice mux gateway, in a point-to-multipoint application over an IP network.
Central Site
T1s
PSTN
10/100BaseT
10/100BaseT
Site A
MT1207A
T1
Trunk
Digital
Voice
PBX
10/100BaseT
Data
Ethernet LAN
Voice Mux
Gateway
Router
10/100BaseT
IP
Network
10/100BaseT
Site A
Voice Mux
Gateway
T1s
Digital Voice
PSTN
10/100BaseT
Ethernet LAN
10/100BaseT
Site C
FXS
Analog
Voice
10/100BaseT
Data
MT1201A
Ethernet LAN
Figure 1-1. Transmitting LAN Data and Compressed Digital/Analog Voice in
Point-to-Multipoint Application
shows MT120xAs in a point-to-point application over a satellite link.
Here, the serial TDM link is employed to transmit the user LAN data and compressed voice in an n x 64 kbps bit stream, compatible with satellite transmission equipment.
PBX
Ethernet LAN
T1
Channels
Digital
Voice
10/100BaseT
Data
Site A
V.35
Satellite Link
V.35
Site C
FXS
Analog
Voice
MT1200A MT1201A
10/100BaseT
Data
Ethernet LAN
Figure 1-2. Data and Compressed Digital/Analog Voice over Satellite Link
1-2 Overview
Chapter 1 Introduction
Features
Ethernet Links
MT120xA provides two half/full duplex, 10/100BaseT Ethernet ports, each with autonegotiation support. One port functions as the uplink to the IP network, while the other is provided for connecting the user Ethernet LAN to the MT120xA unit.
Together with the MT120xA's integral Ethernet switch, this allows integrating the user LAN traffic with the compressed voice, over a single uplink to the network.
If autonegotiation is disabled, the Ethernet ports can be configured to any of the following operation modes:
• 10BaseT – half or full duplex
• 100BaseT – half or full duplex.
The main link Ethernet port supports direct and indirect connection to the IP network.
Serial Main Link
MT120xA has a single TDM link with a RS-530 interface. This serial port supports n x 64 kbps data rates, from 64 to 2048 kbps.
In addition to the standard RS-530 interface, the following serial interfaces are supported by connecting an interface adapter cable to the MT120xA unit's RS-530 interface:
• X.21
• V.35
Voice Interface
MT1200A and MT1207 each have a single T1 digital voice interface, while
MT1201 has four FXS analog voice channels and MT12 xAE has a single E1 digital voice port. The voice interfaces control the T1 or E1 frames, use G.723.1
(6.4 kbps), G.723.1 (5.3 kbps), G.729 A (8 kbps) and G.711 compression algorithms, and handle CAS/CCS signaling transparently.
Voice Activity Detection mechanism allows optimizing bandwidth utilization, as
MT120xA generates traffic only when voice activity is detected. MT120xA uses the
G.723.1 A and G.729 B techniques for silence suppression and the G.168 standard for echo cancellation (up to 16 ms per channel). MT120xA detects, generates and relays DTMF/MFR2/MFC signals. In addition, MT120xA supports
Group III fax relay (4.8, 9.6, 14.4 kbps) and transmits voice-band modem data.
TDMoIP Multiplexing
MT120xA encapsulates the payload bytes in a UDP frame that is transferred over
IP and over Ethernet.
The number of TDM bytes in a multiplexed frame and packetizing interval are user-configurable.
A destination IP address can be configured for each bundle (see Bundling, below).
Overview 1-3
Chapter 1 Introduction
MPLS Multiplexing
When using non-IP based Ethernet networks or the Serial uplink, the MPLS format can be used instead of TDMoIP. The MPLS header is smaller than the TDMoIP header, saving about 5% in bandwidth.
Bundling
A bundle is a logical internal MT120xA port, containing up to 30 timeslots.
MT120xA supports 12 bundles. A bundle is routed to a defined remote IP address.
Each timeslot can be included in any bundle. At the remote site, it can be connected to any timeslot within a destination bundle.
Bundle QoS supports:
• Labeling IP level priority (ToS).
• VLAN tagging and priority labeling according to IEEE 802.1p&Q.
The user can configure the ToS (Type of Service) of the outgoing IP packets. This allows an en-route layer 3 router or switch that supports ToS to give higher priority to MT120xA traffic for delay-sensitive and secure applications.
MT120xA allows you to configure the whole ToS byte field, since different vendors may use different bits to tag packets for traffic prioritization. This also enables you to work according to various RFC definitions (for example RFC 2474, RFC 791).
Timing
Available timing modes for the T1/E1 voice ports are:
• Loopback – The transmit clock is derived from the TDM receive clock.
• Internal – MT120xA features an internal oscillator. When MT120xA is configured to operate with its internal clock, transmit (Tx) and receive (Rx) trunks use the clock supplied by its internal oscillator.
Available timing modes for the serial main link are:
• DTE – port accepts receive and transmit clock signals from the communication equipment, e.g., modem, connected to the main link. This operation requires an adaptor/cross-cable.
• DCE – MT120xA provides the transmit and receive clock signals, derived from its internal oscillator, to the communication equipment connected to the main link.
Diagnostics
MT120xA supports local (internal) and remote (external) loopback activation on the T1, E1, and FXS channels. The user can also perform tone injection towards the local PBX or analog equipment. In addition, a ping utility is included to confirm IP connectivity to the remote units.
1-4 Overview
Chapter 1 Introduction
Statistics Collection
MT120xA provides extensive statistics collection capabilities, which include
Ethernet (as per RFC 1643) and HDLC statistics, voice, signaling, bundles, and
CPU utilization.
Management
MT120xA can be managed via a local terminal, Telnet or SNMP network management systems. MT120xA has an RJ-45 port for the direct terminal connection. Alternatively, a supervisory terminal can be connected via a modem link.
Software upload and download and configuration can be performed via the local terminal or TFTP. Remote units are managed via Telnet or SNMP over an in-band management link.
MT120xA supports a four-level security and user-authentication system:
• Administrator – Allowed to configure all the MT120xA parameters.
• Operator – Allowed to perform all operations in the system except for user administration (adding/deleting users, changing user definitions).
• Technician – Allowed to test MT120xA and monitor its operation (for example, monitoring alarms).
• Monitor – Allowed to monitor the MT120xA operation.
When MT120xA is managed over Telnet, up to five simultaneous management sessions are allowed. Access to the MT120xA software can be limited to the ASCII terminal and SNMP management by disabling the Telnet access.
1.2 Physical Description
MT120xA is a 1U high, easy-to-install standalone device.
view of the unit.
Physical Description 1-5
Chapter 1 Introduction
The front panel includes LEDs which indicate power supply, alarm and Ethernet main link status. The front panel indicators are described in C
hapter 3.
The rear panel is different for each model.
MT1200A or MT1207A with a T1 voice port and AC power supply.
LINK
CONTROL
T1
USER
ETH
NET
Figure 1-4. Rear Panel of MT1200A/MT1207A
The MT120xA rear panel includes the following:
• One of the following voice interfaces:
Single T1 digital voice port
Four FXS analog voice ports
Single E1 digital voice port
• Two Ethernet ports (one for the main link, one to connect to the user LAN)
• One serial uplink (V.35 interface to connect to TDM link)
• One control port (RJ-45 interface; used to connect to a management terminal)
• One power supply (either AC or DC)
The rear panel is described in detail in
Chapter 2
.
1-6 Physical
1.3 Functional Description
illustrates the block diagram of MT120xA.
10/100BaseT
User Port
Chapter 1 Introduction
Main Board
E1 Voice Port
T1 Voice Port
10/100BaseT
Network Port
Control Port
Host
Ethernet
Switch
DSPs
FXS
Voice
Ports
Serial Uplink
Figure 1-5. MT120xA Block Diagram
Voice Interface
Voice interface includes one of the following:
• MT1200 and MT1207: One T1 port, which receives T1 trunks from PBXs
• MT1201: Four FXS analog ports that connect to POTS or faxes.
• MT12 xAE: One E1 port, which receives E1 trunks from PBXs
Signaling
Signaling information is processed according to signaling mode: CAS or CCS.
• CAS – The signaling data is processed by the unit’s host by extracting the
ABCD bits and reporting any change in their status to the host. The reporting format is similar to E1. In addition, the signaling DSP employs a refresh mechanism to update the host with the most recent status of the ABCD bits.
The ABCD bits can be manipulated by using translation rules, which are defined by means of signaling profiles.
A profile enables the user to select the translation of each individual signal bit.
The available selections are A, B, C, D (value copied from the corresponding incoming bit), NOT A, NOT B, NOT C, NOT D (inverted value of corresponding incoming bit), 0 (always 0), and 1 (always 1).
In addition to the translation of individual bits, the signaling profiles can also be used to define the signaling bit patterns that indicate the idle and OOS states.
Functional Description 1-7
Chapter 1 Introduction
Note
• CCS – The signaling information is transferred transparently to the host, which encapsulates the HDLC frame with the proper IP header and sends it to the main link. The following protocols are supported: ISDN, QSIG and SS7. HDLC data can be extracted from any set of timeslots and sent to a single destination.
When operating with SS7 signaling, it is possible to control the amount of keep-alive messages transferred over the signaling links.
Compression
The DSPs handle the voice traffic by compressing it according to G.723.1 (6.4 or
5.3 kbps) and G.729 A (8 kbps), or digitizes it according to the G.711 requirements (A-law and µ-law). Compression methods are user-selectable per bundle.
Every six voice timeslots are handled by a single DSP. Each DSP supports one compression method at any time. MT1200 and MT1201 are each equipped with a single DSP, while MT1207 has four and MT12
0xAE has five.
Voice Activity Detection
Voice Activity Detection (VAD) uses digital signal processing techniques to distinguish between silence and speech on a voice connection. VAD reduces the bandwidth requirements of a voice connection by generating traffic only during periods of active voice conversation. With Comfort Noise Generation supported at the remote site, VAD significantly reduces bandwidth consumption without degrading voice quality. VAD achieves additional bandwidth savings when combined with voice compression techniques.
TDMoIP Multiplexing
Compressed voice payload is multiplexed by using the TDMoIP technique. The multiplexing is performed by the MT120xA software. The DSPs send a continuous stream of voice packets; which are put together into a TDMoIP frame by adding
AAL2 headers and a TDMoIP header.
structure.
TDMoIP
Header
AAL2
Header
Voice
Packet
AAL2
Header
Voice
Packet
Figure 1-6. TDMoIP Frame Structure
The size of the TDMoIP frame is determined by the following parameters:
• Packetizing interval – The time interval allocated for the TDMoIP frame aggregation (10 to 90 msec).
• Maximum bytes per multiplexed frame – The maximum size of each frame
(100 to 1461 bytes).
The MT120xA continues filling the TDMoIP frame until one of the conditions defined by the above parameters is met.
1-8 Functional
Chapter 1 Introduction
Ethernet Frame
At a later stage, the TDMoIP frame becomes a part of the standard Ethernet frame, which also includes a UDP header, IP header and MAC. The Ethernet frames are forwarded to the CPU, which sends them to the Ethernet and Serial main links.
illustrates the structure of the MT120xA Ethernet frame.
describes the fields of the MT120xA Ethernet frame.
Ethernet
IP
UDP TDMoIP AAL2 Voice
AAL2
Voice
AAL2
Voice Ethernet
Note
Figure 1-7. Ethernet Frame Structure
When using the Serial main link, an additional 4 bytes are added to the packet
(HDLC framing).
Functional Description 1-9
Chapter 1 Introduction
MAC
Layer
Table 1-1. Ethernet Frame Fields
Field Length (bytes) Field
7 Preamble
1
6
SFD
Destination MAC Address
LLC
Layer
2 Type
1 Vers/HLEN
IEEE 802.1p&Q VLAN Tagging
(additional 4 bytes if enabled)
IP Layer
2 Identification
1 Flags/Fragment Offset (most)
1
1
Fragment Offset (least)
Time to Live
1 Protocol
UDP
Layer
2
2
2
4
4
Source IP Address
Destination IP Address
UDP Source Port
UDP Destination Port
UDP Message Length
Data
Layer
MAC
Layer
...
Payload
4 CRC
Note: The UDP source port field is used to transfer a destination bundle number.
1-10 Functional
Chapter 1 Introduction
VLAN Support
MT120xA supports VLAN, according to IEEE 802.1p&Q. When VLAN support is enabled, MT120xA adds four bytes to the MAC layer of the Ethernet frame. The content of these bytes, MAC layer priority and VLAN ID, can be set by the user. In this mode, only VLAN format frames are sent and received by MT120xA. The following figure describes the VLAN tag format. user_priority
VID
81 00
8 6 5 4 1 8
Note
802.1D Tag Protocol Type
(802.1QTagType)
Priority
VLAN ID
Figure 1-8. VLAN Tag Format
UDP Support
Table 1-2. UDP Source Port as Destination Voice Port
Field Length (Bits) Field Description
2 bytes UDP Source Port*
2 bytes UDP Destination Port
Value
2 – 497d
2142d
* – The MSB of this field can be either 1 or 0 for inband end-to-end proprietary signaling.
The UDP Source Port field is used for destination voice bundle indication. For example, if the destination is:
Bundle 1 – 02, Bundle 2 – 03, Bundle 3 – 04, Bundle 4 – 05, etc.
For more information about VLAN tagging, see IEEE Std 802.1p&Q.
Ethernet Main Link (ETH NET Port)
The 10/100BaseT main link receives Ethernet frames from the voice modules via the Ethernet switch and forwards them to the remote device over the IP network.
The 10/100BaseT main link supports full duplex transmission with autonegotiation and half duplex with the backpressure option.
Serial Main Link
The RS-530 serial main link receives Ethernet frames from the voice modules via the Ethernet switch and forwards them to the remote device over a TDM network or a leased line.
1
Functional Description 1-11
Chapter 1 Introduction
Ethernet User LAN (ETH USER Port)
The 10/100BaseT user LAN port receives Ethernet frames from the user's LAN via the internal Ethernet switch and forwards them to the remote device over the main link. This port supports full duplex transmission with autonegotiation and half duplex with the backpressure option.
Bandwidth Utilization when using TDMoIP
By using TDMoIP multiplexing and the voice activity detection, MT120xA supports a higher number of voice channels over TDM than it is possible by utilizing conventional compression methods alone. TDMoIP multiplexing and grouping the timeslots of compressed voice together into bundles with a common IP address reduces the actual bandwidth used per channel to as low as 4 kbps (up to 16:1), when all channels are active. Better compression, up to 20:1, is achieved when some of the voice channels are idle.
Note
The actual compression achieved at any time depends on the voice activity on the network, the signaling system in use, and the number of modem/fax calls.
The actual bandwidth utilization is determined by the following factors:
• Header sizes:
Ethernet – 18 bytes
IP – 20 bytes
UDP – 8 bytes
TDMoIP – 4 bytes
VLAN (if exists) – 4 bytes.
• Size of the voice packet:
G.723 – 31 bytes (AAL2 header [3 bytes] + voice header [4 bytes] + compressed voice payload [24 bytes])
G.729 – 17 bytes (AAL2 header [3 bytes] + voice header [4 bytes] + compressed voice payload [10 bytes]).
• Packet interval:
G.723.1 – 30 msec
G.729 – 10 msec.
• Number of timeslots in a bundle
• Silence percentage. Studies show that an average person speaks only 40% of the time during a telephone conversation. 50% of the time is spent listening to the other party, while the remaining 10% is spent quietly contemplating.
• Connectivity packets – 64 bytes per minute.
1-12 Functional
Chapter 1 Introduction
Calculating Approximate Bandwidth Utilization (TDMoIP)
Let us calculate an approximate bandwidth for 30 timeslots in one bundle with
G.723.1 compression, 60 % of silence:
{
[(50 x 1000/40) + (30 x 31 x 1000/30 x 0.4)] x 8
}
1000
+ 0.00853 = 109.208 kbps where:
• 50 – size of Ethernet, IP, UDP, TDMoIP headers
• 1000/40 – packet per seconds (pps) transmission rate, calculated according to the packetizing interval chosen (40 msec in this example)
• 30 – number of timeslots
• 31 – size of the compressed G.732 packet plus AAL2 header and voice payload
• 0.4 – 60% of silence
• 8 – conversion from bytes to bits
• 1000 in the denominator – conversion from bits to kilobits
• 0.00853 – connectivity packets rate (64 bytes per minute) converted to kbps.
Bandwidth Utilization when using MPLS
When using non-IP based Ethernet networks or the Serial uplink, the MPLS format can be used instead of the TDMoIP multiplexing format. The MPLS header is smaller than the TDMoIP header (23 rather than 50 bytes), saving about 5% in bandwidth when compared to TDMoIP multiplexing.
The actual bandwidth utilization is determined by the following factors:
• Header sizes:
Ethernet – 18 bytes
MPLSoAAL2 – 5 bytes
• Size of the voice packet:
G.723 – 31 bytes (AAL2 header [3 bytes] + voice header [4 bytes] + compressed voice payload [24 bytes])
G.729 – 17 bytes (AAL2 header [3 bytes] + voice header [4 bytes] + compressed voice payload [10 bytes]).
• Packet interval:
G.723.1 – 30 msec
G.729 – 10 msec.
• Number of timeslots in a bundle
• Silence percentage. Studies show that an average person speaks only 40% of the time during a telephone conversation. 50% of the time is spent listening to the other party, while the remaining 10% is spent quietly contemplating.
• Connectivity packets – 64 bytes per minute.
Functional Description 1-13
Chapter 1 Introduction
Calculating Approximate Bandwidth Utilization (MPLS)
The approximate bandwidth for 30 timeslots in one bundle with G.723.1 (6.4 kbps) compression, 60 % of silence is calculated as follows:
{
[(23 x 1000/40) + (30 x 31 x 1000/30 x 0.4)] x 8
}
+ 0.00853 = 103.80853 kbps
1000 where:
• 23 – size of Ethernet and MPLSoAAL2 headers
• 1000/40 – packets per second (pps) transmission rate, calculated according to the packetizing interval chosen (40 msec in this example)
• 30 – number of timeslots
• 31 – size of the compressed G.732 packet plus AAL2 header and voice payload
• 0.4 – 60% of silence
• 8 – conversion from bytes to bits
• 1000 in the denominator – conversion from bits to kilobits
• 0.00853 – connectivity packets rate (64 bytes per minute) converted to kbps.
1-14 Functional
Chapter 1 Introduction
Ethernet
Links
1.4 Technical Specifications
Number of Links
2
Standards
Data Rate
Statistics
Range
Connectors
Serial Link
Interface
Data Rate
Timing
Connector
Voice Ports
Configuration
T1 Port
Number of Ports
(MT1200A,
MT1207A)
Data Rate
Standards
Line Code
Zero Suppression
IEEE 802.3, 802.3u, Ethernet 802.1p&Q
10 or 100 Mbps, half duplex or full duplex, autonegotiation support
According to RFC 1643 or RFC 2665:
• Received frames – Correct Frames, Correct Octets,
Alignment Errors, FCS Errors
• Transmitted frames – Correct Frames, Correct Octets,
Single Collision, Multiple Collision, Deferred
Transmission, Late Collision, Carrier Sense Error
Up to 100m (328 ft) over UTP Cat.5 cable
RJ-45, 8-pin per link
• RS-530
• V.35 (requires adapter cable)
• X.21 (requires adapter cable) n x 64 kbps, for rates from 64 to 2048 kbps
• DCE
• DTE (requires adapter/cross cable)
DB-25, female
• MT1200A and MT1207A: One T1 digital voice port
• MT1201A: Four FXS analog voice ports
• MT12 0AE: One E1 digital voice port
One
1.544 Mbps
ANSI T1.403, ITU-T Rec. G.703
AMI
B8ZS
Technical Specifications 1-15
Chapter 1 Introduction
Receive Signal Level 0 to -36 dB with CSU
0 to -30 dB without CSU
Transmit Signal Level 0, -7.5, -15, or -22.5 dB with CSU
±
2.7V (
±
10%) at 0–655 ft without CSU
Jitter Performance Per AT&T TR-62411, G.824
Line Impedance
100
Ω
, balanced
E1 Port
Number of Ports
One
(MT12
0xAE)
Data Rate 2.048 Mbps
Standards
ITU-T Rec. G.703, G.704, G.706, G.732, G.823
Framing
G.732S and G.732N with or without CRC-4, in compliance with ITU-T Rec. G.703, G.704, G.732 requirements
HDB3
Receive Signal Level
0 to -43 dB with LTU
0 to -12 dB without LTU
Transmit Signal Level ±3V (±10%)
Jitter Performance
Per ITU-T G.823
Line Impedance
120Ω, balanced
75Ω, unbalanced
Connector
RJ-45, balanced
Two BNC coaxial, unbalanced
1-16 Technical
Chapter 1 Introduction
FXS
Ports
Number of Ports
Four
(MT1201A)
Analog Parameters
ITU-T standards: G.713, 2-wire for voice and signaling
Nominal level: 0 dBm
Signaling
Connectors
Nominal impedance: 600Ω
Return loss (300 to 3400 Hz): better than 20 dB
Frequency response (Ref: 1020 Hz):
• 300 to 3000 Hz: ±0.5 dB
• 250 to 3400 Hz: ±1.1 dB
Level Adjustment, soft selectable:
• TX: +5 dBm to -10 dBm
• RX: +5 dBm to -10 dBm
• Steps: 2 dB (±0.1 dB), nominal
Signal to Total Distortion, G.712, G.713 method 2:
• 0 to -30 dBm0: better than 33dB
• +3 to -45 dBm0: better than 22dB
Idle channel noise: better than -70 dBm0 (+20 dBrnc)
Signaling type: EIA RS-464 Loop-Start
On-Hook/Off-Hook Threshold:
• 3V to 24V between TIP and RING at off-hook state
• Higher than 25V between TIP and RING at on-hook state
Feed Current: 24 mA ±10%
Ringer:
• Voltage: 50 VRMS (±10%), overload protected
• Frequency: 25 Hz (±10%)
• Cadence: 1 sec ON / 3 sec OFF (default), userconfigurable
RJ-11 per port
Technical Specifications 1-17
Chapter 1 Introduction
Voice
Processing
Compression
Algorithms
Silence Suppression
G.723.1A, G.729B
Echo Cancellation
G.723.1, G.729 A, G.711 (a-law/µ-law)
16 ms per channel as per G.168
Fax Relay
Group III: 4.8, 9.6, 14.4 kbps
Voice-Band Modem
Transparent transfer
MF Signaling
Support
Control Port
Standard
Data Rate
DTMF, MFR2, MFC detection, generation and relay
V.24/RS-232 (DCE)
9.6, 19.2, 38.4, 57.6 or 115.2 kbps
Connector
RJ-45
Diagnostics
Tests
Local and remote loopbacks, tone injection towards local
PBX, ping utility
Statistics Collection
• Ethernet
• CPU utilization
• HDLC
• Bundles
• Voice
• Voice Rx and Tx signaling
Alarm
Indicators
ALM (red)
ETH (green)
PWR (green)
Power Supply
Input
Ethernet link status
Power
AC Source: 100 to 240 VAC, 50/60 Hz, 40W
DC Source: -36 to -72 VDC (-48 VDC, nominal)
Consumption
MT1201A: AC: 13.5 W; DC: 12.5 W
Physical
Height
Width
Depth
Weight
Environment
Operating
Temperature
MT1200A, MT1207A, MT12
0AE: AC: 10.2 W DC: 9.0 W
4.3 cm (1.7 in)
21.5 cm (8.5 in)
23.7 cm (9.3 in)
2.0 kg (4.4 lb)
0 to 50°C (32 to 122°F)
Storage Temperature -20 to 70°C (4 to 158°F)
Humidity
Up to 90%, non-condensing
1-18 Technical
Chapter 2
Installation and Setup
This chapter describes installation and setup procedures for the MT120xA device.
After installing the unit:
• Refer to
Chapter 3
for the operating instructions.
• Refer to
Chapter 4
for the detailed system configuration procedures using an
ASCII terminal connected to the MT120xA control port.
If a problem is encountered, refer to
Chapter 6
and
Chapter 7
for test and diagnostic instructions.
Warning
Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and maintenance of this product.
2.1 Site Requirements and Prerequisites
The AC-powered MT120xA unit should be installed within 1.5 m (5 ft) of an easily-accessible, grounded AC outlet capable of furnishing the voltage in accordance with MT120xA nominal supply voltage.
The DC-powered MT120xA-DC unit requires a -48 VDC power source, which must be adequately isolated from the main supply.
Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables.
The ambient operating temperature of MT120xA is 0 to 50°C (32 to 122°F), at a relative humidity of up to 90%, non-condensing.
Chapter 2 Installation and Setup
2.2 Package Contents
The MT120xA package includes the following items:
• One MT120xA unit
• MT120xA installation and operation manual
• CBL-RJ45/D9/F/STR cable for ASCII terminal connection
• AC power cord or DC power supply connector kit.
2.3 Installation and Setup
The MT120xA unit is designed for desktop or bench installation and is delivered as a fully assembled unit. No provisions are made for bolting the unit to a tabletop.
To install MT120xA:
1. Determine the required configuration of MT120xA, in accordance with your application.
2. MT120e1 only: Set the E1 internal jumpers to match the E1 balanced or unbalanced connection type; set the ground reference jumpers.
3. Connect the voice port(s).
4. Connect the TDM main link to the 10/100BaseT (NET Ethernet) port or the serial V.35 port.
5. Connect the LAN to the USER Ethernet port.
6. Connect an ASCII terminal or a PC running a terminal emulation software.
7. Connect power to the unit.
Setting the E1 Voice Port Internal Jumpers (MT120 xAE only)
Opening MT120e1A Case
In order to access internal jumpers of MT120e1A, you must open the unit’s case.
To open the case:
1. Disconnect the power cable from the electricity outlet.
2. Disconnect all cables from the MT120e1A.
3. Release the two screws on each side panel of the unit.
4. Release the screw on the rear panel of the unit.
5. Slide the top cover backward to open the case.
2-2 Installation and Setup
Setting the E1 Voice Port Internal Jumpers
Chapter 2 Installation and Setup
If the MT120 xAE uses the E1 voice port, you may need to set the internal jumpers to match the E1 connection type: balanced or unbalanced. In addition, the signal ground can be connected to the frame ground or floating. If the default factory settings described below fit your requirements, skip this section and proceed to the next section.
To set the internal jumpers:
1. Release the two screws holding the DSP board (see
Figure 2-1
).
2. Remove the DSP board by lifting it straight up.
3. Set the MT120 xAE internal jumpers (see
Figure 2-1
and
Table 2-1
).
BAL
UBAL
NO
YES
BAL
UBAL
J6
DSP Board
Main Board
Figure 2-1. MT120 xAE E1 Jumper Locations
Installation and Setup 2-3
Chapter 2 Installation and Setup
Table 2-1. MT120 xAE E1 Jumper Settings
Jumper
Description
Values
Factory
Setting
E1 interface type jumpers,
J1, J2, J5, J6,
J7
Input BNC ground reference
RX-GND, J3
Signal ground reference
FGND, J4
Select the E1 interface type: balanced or unbalanced.
BAL
– E1 balanced interface
All the jumpers must be set to the same position
(balanced or unbalanced).
UNBAL
– E1 unbalanced interface
Control the ground reference of the input BNC when the unbalanced interface is used.
In accordance with ITU-T recommendations, this jumper should be set to NO (when the unbalanced interface is used, the input line is normally grounded at the other side). This also suits operation with the balanced interface.
YES
– The input BNC shield is connected to the frame ground
NO
– The input BNC shield is floating
Control the connection of pin 3 and pin 6 of the
RJ-45 E1 connector to the frame ground.
YES
– Pin 3 and pin 6 are connected to the frame ground
NO
– Pin 3 and pin 6 are not connected to the frame ground
BAL
NO
NO
Closing MT120 xAE Case
After completing the internal settings, close the unit case.
To close the case:
1. Re-install the top cover.
2. Secure the top cover with the four side panel screws and one rear panel screw.
Connecting the Interfaces
shows the rear panel of an AC-powered MT120
the rear panel of a DC-powered MT1200A or MT1207.
panel of an AC-powered MT1201A.
LINK
CONTROL
TX E1 RX
USER
ETH
NET
Figure 2-2. MT120
xAE Rear Panel (E1 Voice Port and AC Power Supply)
2-4 Installation and Setup
Chapter 2 Installation and Setup
+ 48V
LINK CONTROL T1
USER
ETH
NET
Figure 2-3. MT1200/MT1207A-DC Rear Panel (T1 Voice Port and DC Power Supply)
1 2
FXS
3 4
LINK
CONTROL
USER
ETH
NET
Figure 2-4. MT1201A Rear Panel (FXS Voice Ports and AC Power Supply)
Connecting the MT12
0xAE E1 Voice Port
The MT12 xAE’s E1 voice port terminates in an RJ-45 balanced connector.
Appendix A
specifies the pinout of the E1 connector.
To connect the balanced E1 interface:
• Connect the incoming E1 link to the RJ-45 connector on the MT12 xAE rear panel, designated E1.
To connect the unbalanced E1 interface:
1. Connect the receive line, using a 75Ω coaxial cable to the BNC connector labeled RX.
2. Connect the transmit line, using a 75Ω coaxial cable to the BNC connector labeled TX.
Connecting the MT1200A or MT1207A T1 Voice Port
The T1 voice port terminates in an RJ-45 balanced connector.
Appendix A
specifies the pinout of the T1 connector.
To connect the T1 interface:
• Connect the incoming T1 link to the RJ-45 connector on the MT1200A or
MT1207A rear panel, designated T1.
Connecting the MT1201A FXS Voice Ports
The FXS voice ports terminate in four RJ-11 connectors.
Appendix A
specifies the pinout of the FXS connectors.
To connect the FXS interface:
• Connect each 2-wire line to one of the four RJ-11 connectors on the
MT1201A rear panel, designated FXS.
Installation and Setup 2-5
Chapter 2 Installation and Setup
Connecting the Main Link
The MT120xA Ethernet main link interfaces terminate in two 8-pin RJ-45 connectors.
Appendix A
specifies the pinout of the Ethernet connectors. The
Ethernet main link port supports connection via straight and cross cables.
To connect the Ethernet main link:
• Connect the IP uplink to the RJ-45 connector designated NET ETH.
To connect the serial main link:
• Connect the serial V.35 link to the DB-25 connector designated LINK.
The serial main link interface terminates in a female DB-25 connector.
Appendix A
specifies the pinout of the serial connector.
Connecting the User LAN Port
The user LAN can be connected to one of the available Ethernet ports (the other can be used as the uplink to the IP network).
Appendix A
specifies the pinout of the Ethernet connectors.
To connect the Ethernet main link:
• Connect the user LAN to the RJ-45 connector designated USER ETH.
Connecting the ASCII Terminal
The MT120xA control port terminates in an 8-pin RJ-45 connector.
Appendix A
specifies the pinout of the control port connector.
To connect the ASCII terminal directly to the CONTROL port:
1. Connect the CBL-RJ45/D9/F/STR cable to the RJ-45 connector, designated
CONTROL.
2. Connect the other side of the cable to the ASCII terminal, or PC running a terminal emulation software.
Connecting the Power
MT120xA includes AC or DC power supply. To connect MT120xA to the power source, refer to the appropriate section below, depending on your version of the unit (AC or DC).
Warning
Before switching on this unit and connecting or disconnecting any other cable, the protective earth terminals of this unit must be connected to the protective ground conductor of the mains (AC or DC) power cord. If you are using an extension cord (power cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or outside the instrument) or disconnecting of the protective earth terminal can make this unit dangerous. Intentional interruption is prohibited.
2-6 Installation and Setup
Chapter 2 Installation and Setup
Connecting AC Power
AC power is supplied to MT120xA through a standard 3-prong plug (see
AC power should be supplied through the 1.5 m (5 ft) standard power cable terminated by a standard 3-prong plug. The cable is provided with the unit.
To connect AC power:
1. Connect the power cable to the power connector on the MT120xA rear panel.
2. Connect the power cable to the electricity outlet.
The unit will turn on automatically upon connection to the electricity supply.
Connecting DC Power
To connect DC power:
• Refer to the DC power supply connection supplement.
2.4 Installing MT120xA in a 19-Inch Rack
The MT120xA unit can be installed in a 19-inch rack. One or two MT120xA units can be installed in a single rack slot.
Installing MT120xA in a 19-inch rack requires the optional MT1202 Rack-Mount
Kit.
Rack-Mount Kit Contents
Rack adapter components for installing a single unit include:
• One short bracket
• One long bracket
• Four 6–32 UNC (3.5 mm) screws.
Rack adapter components for installing two units include:
• Two short side brackets
• Two long side adapters
• Two short side adapters
• Six 4–40 UNC (2.8 mm) screws
• Ten 6–32 UNC (3.5 mm) screws.
Equipment Needed
The installation procedure requires use of the following tools and components, which are not included in the Rack-Mount Kit:
• One 3 mm Philips screwdriver
• Four 5 mm Philips screws.
Installing MT120xA in a 19-Inch Rack 2-7
Chapter 2 Installation and Setup
Installation
Disconnect all cables including the power cord from the unit before performing the installation procedures.
Warning
To install a single MT120xA unit:
1. Fasten the short bracket to the left side of the unit using two 6–32 UNC screws
(see
2. Repeat step 1 to fasten the long bracket to the right side of the unit.
3. Place the unit in the rack and fasten the brackets to the side rails of the rack using two 5 mm Philips screws (not included in the kit) on each side.
Short Bracket
Long Bracket
Figure 2-5. Bracket Assembly for Installing a Single MT120xA Unit in a 19-inch Rack
To install two MT120xA units:
1. Attach the short brackets to the outer sides of the two units, as explained in step 1 of the single unit installation procedure (see
2. Attach the long and short side adapters to the inner panels using six 6–32 UNC screws (see
2-8 Installing MT120xA in a 19-Inch Rack
Chapter 2 Installation and Setup
3. Fasten the two units together by sliding the side adapters into each other.
Make sure that the protrusions of the long adapters enter their corresponding slots.
4. Secure the two units together by using six 4–40 UNC screws inserted into the top and bottom of each side adapter.
5. Place the two-unit assembly in the rack and fasten the brackets to the side rails of the rack using two 5 mm Philips screws (not included in the kit) on each side.
Short Side
Adapters
6-32
Screw
4-40
Screw
Long Side
Adapters
Figure 2-6. Bracket Assembly for Installing Two MT120xA Units Side by Side in a 19-inch Rack
Installing MT120xA in a 19-Inch Rack 2-9
Chapter 2 Installation and Setup
2-10 Installing MT120xA in a 19-Inch Rack
Chapter 3
Operation
This chapter provides the following information for MT120xA:
• MT120xA front-panel indicators
• Operating procedures (turn-on, front-panel indications, performance monitoring and turn-off).
The installation procedures given in
Chapter 2
must be completed and checked before attempting to operate the MT120xA.
3.1 Front Panel Indicators
The MT120xA front panel includes a series of LED indicators that show the current operating status of the unit (see
MT120xA indicators.
ALM
PWR
ETH
Figure 3-1. MT120xA, Front Panel
Table 3-1. MT120xA LEDs
Name Function
ALM (red)
ETH (green)
PWR (green)
ON – Alarm is present
ON – 10/100BaseT link is established on network port
ON – Power supply is ON
Front Panel Indicators 3-1
Chapter 3 Operation
3.2 Operating MT120xA
Turning On MT120xA
To turn on MT120xA:
• Connect the power cable to the electricity outlet.
The PWR indicator lights up and remains lit as long as MT120xA receives power.
Normal Indications
shows the correct status of the indicators a few seconds after power-up.
Table 3-2. MT120xA Indicator Status
Indicator Status
PWR ON
ETH ON
ALM ON
If the above LED indications do not appear following initial power turn-on, refer to
Chapter 6
for the diagnostic test instructions.
Turning Off MT120xA
To turn off MT120xA:
• Disconnect the power cable from the electricity outlet.
3.3 Default Settings
MT120xA is managed by an ASCII terminal or PC running a terminal emulation program via menu-driven embedded software.
the MT120xA configuration parameters.
Table 3-3. MT120xA Default Settings
System
Set Host IP address
Set Subnet Mask
Set Default Gateway
0.0.0.0
0.0.0.0
0.0.0.0
Read public
Write Private
Trap public
3-2 Default
Chapter 3 Operation
Table 3-3. MT120xA Default Settings (Cont.)
Manager list
Set Baud Rate (bps)
Timeout (min)
0.0.0.0
9600
3
Telnet Enable
Main Link Serial Port
Signaling Profile
SS7 Keep-Alive Suppression Rate 0% - No Suppression / Not SS7
Switch LAN
(for both Network and User Ports)
Set Auto Negotiation Disable
Set Max Capability
Bundle
Enter Bundle Number
Connect
10BaseT half duplex
1
No
Function TDMoIP
Max Bytes In Multiplexed Frame 500
Destination IP 0.0.0.0
Destination Bundle
Packetizing Interval (msec)
Connectivity Packet Rate
1
30
60
Connectivity Timeout Cycles
TOS Parameters (Precedence)
TOS Parameters (Delay)
TOS Parameters (Throughput)
TOS Parameters (Reliability)
Coder/Rate
3
Routine
Normal
Normal
Normal Reliability
G.723.1/6.4
Modem Disable
Fax Enable
Fax Rate
MF Relay
14.4 kbps
Disable
Minimum Pulse Width
Minimum Power Level
VLAN Parameters (Vlan exists)
60 msec
-12 dBm
No
VLAN Parameters (Vlan ID) 26
VLAN Parameters (Vlan Priority) 0
Default Settings 3-3
Chapter 3 Operation
Table 3-3. MT120xA Default Settings (Cont.)
T1 Port (MT1200A, MT1207A)
Connect
Clock Source
Frame
Interface Type
Line Code
Rx Sensitivity (CSU mode only)
Tx Gain Level (CSU mode only)
Line Length (DSU mode only)
Restoration Time
No
Lbt
Esf
Dsu
B8ZS
LOW (-30 dB)
0 dBm
0-133 ft
1 second
Idle Code ff
Signaling CAS
Profile 1
E1 Port (MT120
xAE)
Connect No
Frame
Restoration Time
Clock Source
Interface Type
732S
1 second
Lbt
Ltu
Idle Code ff
Signaling CAS
Profile 1
FXS Ports (MT1201A)
Ring Timeout 120 seconds
On hook duration in Flash
Period #1: Ring
Period #1: Silence
Period #2: Ring
Period #2: Silence
TX gain
RX gain
700 seconds
1 second (10 * 100 msec)
3 seconds (30 * 100 msec)
0
0
0
-10
FXS Signaling Parameters
3-4 Default
Table 3-3. MT120xA Default Settings (Cont.)
Timeslots
Update from Time Slot
To Time Slot
1
1
Type N.C.
Bundle 1
Destination Port ID
Destination Time Slot
1
1
Serial Port
Interface Type V35
Connect No
Chapter 3 Operation
Clock Mode
Clock Invert
Control Signals
DTE
No
Ignore
Fragmentation 610
Default Settings 3-5
Chapter 3 Operation
3-6 Default
Chapter 4
Management from a
Terminal
The configuration of MT120xA is performed via menu-driven embedded software, using a standard ASCII terminal or a PC running a terminal emulation application connected to the rear panel CONTROL port. Alternatively, you can configure
MT120xA via Telnet connection, which also establishes an inband management link to the remote unit.
4.1 Preparing for the Control Session
This section describes how to prepare MT120xA and the supervisory terminal for the control session.
Control Port Interface Characteristics
MT120xA includes a V.24/RS-232 asynchronous DCE port, designated CONTROL.
The port terminates in an RJ-45 connector. The control port continuously monitors the incoming data stream and immediately responds to any input string received through this port.
The terminal is connected directly to the MT120xA control port. Since terminals usually have DTE interfaces, the connection to the port is made by means of a straight cable, CBL-RJ45/D9/F/STR, supplied with the unit.
Preparing the Terminal
Any standard ASCII terminal (a “dumb” terminal or a personal computer running a terminal emulation application) equipped with a V.24/RS-232 communication interface can be used to configure MT120xA.
Initiating a Control Session
To initiate a control session:
1. Connect the terminal cable to the CONTROL connector on the MT120xA back panel.
2. Connect the terminal cable to the serial port of the control terminal.
3. Turn the control terminal on.
Preparing for the Control Session 4-1
Chapter 4 Management from a Terminal
4. Configure the terminal to the default communication parameters: 9.6 kbps, one start bit, eight data bits, no parity, one stop bit, no flow control, VT100 emulation.
5. Turn MT120xA on.
Levels of Security
MT120xA supports a four-level security and user authentication system:
• Administrator – Allowed to configure all the parameters of MT120xA.
• Operator – Allowed to perform all operations in the system, except for user administration (adding/deleting users, changing user definitions).
• Technician – Allowed to test MT120xA and monitor its operation (for example, monitoring alarms).
• Monitor – Allowed to monitor the MT120xA operation.
The maximum number of users supported by MT120xA is 20. When managing
MT120xA over Telnet, up to five simultaneous management sessions are permitted. Only one administrator is allowed to enter the management session at a time.
MT120xA displays the management menus in accordance with a user’s access rights. For example, configuration screens dealing with the unit configurations are not available to users who logged in as technicians or monitors.
Note
Default Security Configuration
MT120xA is supplied with one administrator account:
• User name: admin
• Password: 12345.
When the first management session is initiated, it is recommended to create a new administrator account, and delete the default one.
•
If the password is lost, consult your local Black Box distributor.
4-2 Preparing for the Control Session
Chapter 4 Management from a Terminal
4.2 Navigating the Management Menus
This section provides a general description of the software menu operation and conventions for navigating the menus.
Appendix C
lists all menus of the MT120xA management software.
Choosing Parameters
To choose an option:
• Type the number corresponding to the option, and press <Enter>.
The screen for the chosen option is displayed.
To correct an erroneous entry:
• Press <Backspace> to clear the error, then enter the correct characters.
Alternatively, press <Esc> to exit the current menu, and then return to the menu to re-enter the required value.
Saving and Aborting Configuration Changes
You must save the configuration changes by updating the MT120xA database. If the database is not updated, MT120xA discards all the user settings when it is reset. You can save changed values at any stage of the configuration procedure.
Alternatively, you can abort the new settings and return to the previous values.
Note
To save the changes:
1. Type @ (Shift+2) and press <Enter>.
MT120xA displays the following confirmation message:
Are you sure you want to update data base ?
Press Y/N :
2. Type Y to save the changes.
MT120xA displays the following message:
Data base was changed. Press any key to continue.
3. Press any key to continue the management session.
•
Each time you update the MT120xA database, the management software analyzes the changes. If a major error is detected, MT120xA aborts the database update and displays the following message:
Data base wasn't changed. Sanity Error - Check alarm.
In this case, check the sanity error, as described in Chapter 7, and re-enter the erroneous values.
To undo the changes:
1. Type # (Shift+3) and press <Enter>.
MT120xA displays the following confirmation message:
Are you sure you want to undo data base ?
Press Y/N :
2. Type Y to abort the changes and use the previous database settings.
Navigating the Management Menus 4-3
Chapter 4 Management from a Terminal
4.3 Starting the Control Session
Once you have installed MT120xA, and completed the installation and operation procedures described in
Chapter 2
and
Chapter 3
, you can start the control session.
You have to enter a user name and password in order to start the MT120xA management software (see
USER NAME:
PASSWORD:
ESC - clear; & - exit
Figure 4-1. Password Request Screen
To enter the user name and password:
1. Type in your user name, and press <Enter>.
2. Type in your password (up to eight characters), and press <Enter>.
The Main menu is displayed (see
>
Main Menu
1. Inventory[]
2. Configuration>
3. Monitoring>
4. Diagnostics>
Please choose item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-2. Main Menu
4-4 Starting the Control Session
Chapter 4 Management from a Terminal
4.4 Displaying the MT120xA Inventory
MT120xA inventory displays information on its hardware and software versions.
To display the MT120xA inventory:
• From the Main menu, choose Inventory.
The MT120xA inventory screen appears (see
Inventory
HW Revision FW Revision SW Revision
MT120xA??? 01.00 01.40 02.00
>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 4-3. Inventory Screen for MT120xA
Note
•
The actual information shown in the Inventory screen depends on the MT120xA model in use.
Displaying the MT120xA Inventory 4-5
Chapter 4 Management from a Terminal
4.5 Configuring the MT120xA System
The MT120xA management software allows you to perform the following:
• Configuring parameters of the Ethernet management connection
• Managing the user database (adding/deleting/changing user details)
• Configuring control port for ASCII terminal connection
• Defining the signaling bits table (for CAS signaling)
• Configuring SS7 keep-alive suppression rate (for CCS signaling)
• Controlling the software versions (see
Appendix B
)
• Changing the real-time system clock settings
• Resetting MT120xA.
To display the System Configuration menu:
1. From the Main menu, choose Configuration.
The Configuration menu appears (see
>
Configuration
1. System>
2. Switch Lan Configuration>
3. Voice Configuration>
4. Serial Port Configuration>
Please choose item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-4. Configuration Menu (MT1200A/MT1207)
2. From the Configuration menu, choose System.
The System menu appears (see
4-6 Configuring the MT120xA System
Chapter 4 Management from a Terminal
System
1. Management>
2. Control Port>
3. Date & Time Update>
4. Factory Default
5. Show Partition Information
6. Set Active Partition
>
7. Reset Unit
8. Open Internal Alarms>
Please choose item <1 to 8>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-5. System Menu
Configuring the Control Port
MT120xA allows you to configure the baud rate and the timeout of the rear panel
CONTROL port.
Configuring the Data Rate
The MT120xA control data port supports baud rates in the range of 9.6 to
115.2 kbps.
To configure the baud rate:
1. From the System menu (see
The Control Port menu appears (see
Configuring the MT120xA System 4-7
Chapter 4 Management from a Terminal
>
Control Port
1. Set Baud Rate (bps)> (9600)
2. Timeout (minutes)[3 - 10]... (3)
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-6. Control Port Menu
2. From the Control Port menu, choose Set Baud Rate.
The Set Baud Rate menu appears.
3. Enter a new baud rate by typing the corresponding number from the Set Baud
Rate menu, and then pressing <Enter>.
Configuring the Timeout
The timeout specifies a time interval after which MT120xA automatically disconnects from the supervisory terminal if no input from the user is detected.
MT120xA supports 3–10 minute timeout.
To configure the timeout:
1. From the Control Port menu, choose Timeout.
2. Enter the desired timeout value by typing the corresponding number, and then pressing <Enter>.
Configuring the Ethernet Management Connection
MT120xA can be managed by a network management station, which is located on the user LAN connected to the unit’s 10/100BaseT port. In order to establish a proper connection, it is necessary to configure the following:
• Host IP address, subnets mask, default gateway, its trap, read and write communities.
• Manager IP addresses.
Configuring the Host IP
IP parameters of the management host are configured via the Host IP menu (see
). Unlike more complex Voice Mux Gateway systems, which use
separate IP addresses for their main link cards and T1/E1 groups, MT120xA
4-8 Configuring the MT120xA System
Chapter 4 Management from a Terminal provides only one IP address. This IP address is used for management connection and for bundle routing.
To configure the IP host parameters:
1. From the System menu, choose Management.
The Management menu appears (see
Management
1. Host IP>
2. Manager List[]>
3. Host Mux Name... ()
4. User Administration>
5. Signaling Configuration>
6. Telnet> (Enable)
>
7. Main Link> (Serial Port)
Please choose item <1 to 7>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-7. Management Menu
2. From the Management menu, choose Host IP.
The Host IP menu appears (see
>
Host IP
1. Set Host IP address ... (0.0.0.0)
2. Set Subnet Mask ... (0.0.0.0)
3. Set Default Gateway ... (0.0.0.0)
4. Trap... (public)
5. Read... (public)
6. Write... (private)
Please choose item <1 to 6>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-8. Host IP Menu
3. From the Host IP, choose the following:
Configuring the MT120xA System 4-9
Chapter 4 Management from a Terminal
Set Host IP Address
to define the host IP
Set Subnet Mask
to define the subnet mask
Set Default Gateway
to set the default gateway IP address
Trap
to enter the name of a community to which the MT120xA will send traps
Read
to enter the name of a community with read-only authorization
Write
to enter the name of a community with write authorization.
4. Enter the desired value, and press <Enter>.
Defining the Manager List
You can define the network management stations to which the SNMP agent of the
MT120xA will send traps. Up to ten managers can be defined. In addition, you can configure MT120xA to accept Telnet management traffic only from the management stations defined in the manager list (see
below).
To define the manager list:
1. From the Management menu, choose Manager List.
The Manager List menu appears (see
Manager List
Managers ID IP Address
1 0.0.0.0
2 0.0.0.0
| 3 0.0.0.0 v 4 0.0.0.0
5 0.0.0.0
>
1. Change cell ... (0.0.0.0)
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 4-9. Manager List Menu
2. Select a manager by pressing <Shift> U to choose the previous entry in the list or <Shift> D to choose the next entry in the list.
3. Choose Change cell.
4. Enter the desired IP address, and press <Enter>.
4-10 Configuring the MT120xA System
Chapter 4 Management from a Terminal
Configuring Telnet Access
You can disable Telnet access to MT120xA or allow access only to the management stations specified in the manager list (see
above).
By disabling Telnet, you prevent unauthorized access to the system when security of the MT120xA IP address has been compromised. When Telnet access is disabled, MT120xA can be managed via an ASCII terminal or SNMP network management system.
To configure the Telnet access:
1. From the Management menu (
The Telnet menu appears (see
Telnet (Enable)
1. Disable
2. Enable
3. Enable Managers Only
>
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-10. Telnet Menu
2. From the Telnet menu, choose Disable to disable Telnet access, choose
Enable
to enable it, or choose Enable Managers Only to grant the Telnet access only to the management stations specified in the manager list.
Managing the User Database
An administrator manages the database of users who are allowed to operate or monitor the MT120xA system. This allows the administrator to do the following:
• Add a new user
• Delete an existing user
• Change user’s details, including the name, password or access level
• Display the list of users, including date and time.
Configuring the MT120xA System 4-11
Chapter 4 Management from a Terminal
Adding a New User to the Database
To add a new
user:
1. From the Management menu (see
), choose User Administration.
The User Administration menu appears (see
>
User Administration
1. Add New User>
2. Delete User>
3. Change User details>
4. Show all users[]
Please choose item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-11. User Administration Menu
2. From the User Administration menu, choose Add New User.
The Add New User menu appears (see
>
Add New User
1. Enter UserName ... ()
2. Enter Access Level > (x)
3. Enter Password ...
4. Confirm Password and save ...
Please choose item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-12. Add New User Menu
3. From the Add New User menu, choose Enter UserName.
4-12 Configuring the MT120xA System
Chapter 4 Management from a Terminal
Note
4. Type a new user name, and then press <Enter>.
A new user name appears.
•
User names are case-sensitive.
5. From the Add New User menu, choose Enter Access Level to define the new user access level.
6. Choose the desired value (Monitor, Technician, Operator or Administrator) by entering the corresponding number from the Enter Access Level menu.
An access level of a new user is displayed.
7. From the Add New User menu, choose Enter Password.
8. Type the new user password (four to eight characters), and press <Enter>.
MT120xA responds to the password entry with asterisks.
9. From the Add New User menu, choose Confirm Password and save.
10. Re-type the new user password, and press <Enter> to save it.
Deleting an Existing User from the Database
To delete an existing user:
1. From the User Administration menu, choose Delete User.
The Delete User menu appears (see
>
Delete User
1. Enter UserName (to delete) ... ()
2. Confirm and delete ...
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-13. Delete User Menu
2. From the Delete User menu, choose Enter UserName (to delete).
3. Type the name of the user that you intend to delete, and press <Enter>.
4. From the Delete User menu, choose Confirm and delete.
5. Enter the administrator password to confirm the deletion.
Configuring the MT120xA System 4-13
Chapter 4 Management from a Terminal
Changing the User Details
The administrator is allowed to change a user’s password and access level.
To change user details:
1. From the User Administration menu, choose Change User Details.
The Change User Details menu appears (see
>
Change User details
1. Enter UserName (to change) ... ()
2. Change password ...
3. Confirm and save password ...
4. Change access level > (x)
5. Confirm and save access level ...
Please select item <1 to 5>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-14. Change User Details Menu
2. From the Change User Details menu, choose Enter UserName (to change).
3. Type the name of the user whose details you want to change, and press
<Enter>
.
4. From the Change User Details menu, choose Change password.
5. Type the new password, and press <Enter>.
6. From the Change User Details menu, choose Confirm and save password.
7. Re-type the new password, and press <Enter> to confirm the change.
8. From the Change User Details menu, choose Change access level.
The Change Access Level menu appears.
9. Enter a new access value (Monitor, Technician, Operator or Administrator) by entering the corresponding number from the Change Access Level menu.
10. From the Change User Details menu, choose Confirm and save access level.
11. Enter administrator password to confirm the change.
4-14 Configuring the MT120xA System
Chapter 4 Management from a Terminal
Displaying the User List
To display a list of registered users:
• From the User Administration menu, choose Show All Users.
The Show All Users screen appears (see
down the list; press <U> to scroll up the list.
Show all users
UserName Access Level DBchange date DBchange time
1 admin Administrator 3/1/2056 17:08:27
2 qwerty Monitor
| 3 v 4
5
6
7
8
9
10
>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 4-15. Show All Users Screen
Setting the Date and Time
You can set the time on the MT120xA internal real-time clock.
To set date and time:
1. From the System menu (see
The Date & Time Update menu appears (see
>
Date & Time Update
1. Set Time (hh:mm)... (22:39)
2. Set Date (dd/mm/yyyy)... (10/1/2056)
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-16. Date & Time Update Menu
Configuring the MT120xA System 4-15
Chapter 4 Management from a Terminal
2. From the Date & Time Update menu, choose Set Time.
3. Type the new time value in the hh:mm format, and then press <Enter>.
4. From the Date & Time Update menu, choose Set Date.
5. Type the new date value in the dd/mm/yyyy format, and then press <Enter>.
Assigning a Name to the MT120xA Unit
The MT120xA management software allows you to assign a name to the unit to distinguish it from the other devices installed in your system.
To assign a name:
1. From the Management menu (
2. Type the name you want to use to identify this MT120xA device, and then press <Enter>.
The assigned name appears at the top of each terminal screen.
Note
4.6 Configuring Signaling Information
MT120xA allows you to configure the signaling parameters according to the chosen signaling mode: CAS for E1, Robbed Bit MF for T1 or CCS for T1/E1. The signaling mode is configured via the T1/E1 Parameters menu of the voice card (see the
• CAS/Robbed Bit MF – You must configure a signaling profile and signaling table associated with it (ABCD bits, idle code and OOS signals).
• CCS – When working with CCS-SS7, you can configure the fill-in signal unit
(FISU) packets flow by choosing the SS7 keep-alive suppression rate.
•
When changing from CCS to CAS signaling, the MT120xA unit must be rebooted.
Configuring Signaling Profiles
If you are using CAS signaling, you must configure the MT120xA signaling system to make it compatible with the signaling method used by the PBXs connected to the voice T1 or E1 port. The management software allows you to manipulate the
ABCD signaling bits and methods of representation of the idle code and out-ofservice signals generated by the PBXs (see
). Signaling conversion is used
to connect to PBXs that use different signaling formats.
You can store up to five signaling profiles; MT120xA uses only one of them at a time. The signaling profile is configured via the T1/E1 Parameters menu of the
T1/E1 card (see the
4-16 Configuring Signaling Information
Chapter 4 Management from a Terminal
Note
•
The signaling profile configuration is available only for the units operating with CAS signaling.
To configure the signaling profile:
1. From the Management menu (see
Configuration
.
The Signaling Configuration menu appears (see
>
Signaling Configuration
1. Signaling Profile Configuration>
2. SS7 Keep-Alive Suppression rate> ( 0% - No Suppression / Not SS7)
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-17. Signaling Configuration Menu
2. From the Signaling Configuration menu, choose Signaling Profile
Configuration
.
The Signaling Profile Configuration menu appears (see
>
Signaling Profile Configuration
1. Profile Number To Configure[1 - 5] ... (1)
2. Signaling Table Configuration []>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-18. Signaling Profile Configuration Menu
Configuring Signaling Information 4-17
Chapter 4 Management from a Terminal
3. From the Signaling Profile Configuration menu, choose Profile Number To
Configure
.
4. Type the number of the signaling profile that you want to configure by typing a number from 1 to 5, and then press <Enter>.
5. From the Signaling Profile Configuration menu, choose Signaling Table
Configuration
.
The Signaling Table Configuration screen appears (see
Signaling Table Configuration
A Bit B Bit C Bit D Bit
ABCD BITS A B C D
IDLE SIGNAL 1 0 0 0
OOS SIGNAL 1 0 0 0
1. 0 9. D
2. 1 10. NOT D
3. A
4. NOT A
5. B
6. NOT B
7. C
8. NOT C
>
Please select item <1 to 10>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 4-19. Signaling Table Configuration Screen
6. In the signaling table, select the signaling bit that you want to configure by pressing <Tab>.
7. Configure the signaling bit by typing a number corresponding to the desired value (see
4-18 Configuring Signaling Information
Chapter 4 Management from a Terminal
Table 4-1. Signaling Bits Configuration
Parameter Description
A, B, C, D Bit Chooses which incoming bit
(from the remote side) to transmit on the A bit toward the MT120xA’s local PBX.
IDLE SIGNAL
OOS SIGNAL
Chooses the code transmitted on A, B, C, and D bit when the channel is idle
Chooses the code transmitted on A, B, C, and D bit when the channel is out of service
Value
0
– Transmits zero
1
– Transmits one
A
– Transmits the incoming A bit
B
– Transmits the incoming B bit
C
– Transmits the incoming C bit
D
– Transmits the incoming D bit
NOT A
– Inverts the incoming A bit and transmits it
NOT B
– Inverts the incoming B bit and transmits it
NOT C
– Inverts the incoming C bit and transmits it
NOT D
– Inverts the incoming D bit and transmits it
0
– Transmits zero
1
– Transmits one
0
– Transmits zero
1
– Transmits one
Configuring Keep-Alive Suppression Rate
When MT120xA with CCS signaling is connected to PBXs operating with SS7 signaling, the PBXs use one timeslot to transmit signaling information. The signaling information is passed over the signaling link in the form of the following signal units:
• Message signal units (MSUs) provide all signaling associated with call setup and tear down, database query and response, and SS7 network management.
• Link status signal units (LSSUs) provide information on the link status between the network nodes (initiation of link alignment, quality of the signaling traffic etc).
• Fill-in signal units (FISUs) carry no information payload. They occupy the link, when there are no MSUs or LSSUs to send. FISUs are also referred to as
“keep-alive” messages.
Often, in the absence of signaling traffic, the signaling links become flooded with the FISUs, causing communication disruptions. In order to prevent this, you can instruct MT120xA to drop a specified amount of FISUs (up to 90%). You can also disable the FISU dropping by configuring the keep-alive suppression rate to 0%.
This is necessary when working with non-SS7 CCS signaling (for example, ISDN), or if the FISUs are used to acknowledge the receipt of signaling messages. In the latter case, system performance may become unsatisfactory.
To configure the keep-alive suppression rate:
1. From the Signaling Configuration menu (see
Alive Suppression Rate
.
The SS7 Keep-Alive Suppression Rate menu appears (see
Configuring Signaling Information 4-19
Chapter 4 Management from a Terminal
SS7 Keep-Alive Suppression rate ( 0% - No Suppression / Not SS7)
1. 0% - No Suppression / Not SS7
2. 10%
3. 20%
4. 30%
5. 40%
6. 50%
>
7. 60%
8. 70%
9. 80%
10. 90%
Please select item <1 to 10>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-20. SS7 Keep-Alive Suppression Rate Menu
2. From the SS7 Keep-Alive Suppression Rate menu, type the number corresponding to the desired value, and then press <Enter>.
4.7 Configuring the Main Links
It is recommended to configure the main link in the following order:
1. Choose the main link interface you want to use.
2. Configure the main link.
Choosing the Main Link Interface
The main link on the MT120xA can be connected to either the Ethernet interface or the Serial interface.
To specify the main link interface:
1. From the Management menu (see
The Main Link menu appears.
2. Choose the interface to which the main link is connected:
Serial Port
Lan
4-20 Configuring the Main Links
Chapter 4 Management from a Terminal
Configuring the Main Link
Either one of the two Ethernet network ports or the serial port can be configured as the main link for the MT120xA.
Configuring the Ethernet Network Port
The Ethernet ports of the MT120xA main link support auto-negotiation. If the auto-negotiation is disabled, the Ethernet ports can be configured to operate in
10BaseT (half duplex or full duplex) or 100BaseT (half duplex or full duplex) mode.
To configure the Ethernet Network port:
1. From the Configuration menu, choose Switch Lan Configuration.
The Switch Lan Configuration menu appears (see
>
Switch Lan Configuration
1. Network Port Configuration>
2. User Port Configuration>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-21. Switch Lan Configuration Menu
2. To configure the Ethernet main link, choose Network Port Configuration
The Network Port Parameters menu appears (see
Configuring the Main Links 4-21
Chapter 4 Management from a Terminal
>
Network Port Configuration
1. Set Auto Negotiation (Disable)
2. Set Capability > (10baseT Half Duplex)
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-22. Network Port Parameters Menu
3. From the Network Port Parameters menu, choose Set Auto Negotiation to toggle the auto-negotiation setting between enable and disable.
4. If auto-negotiation is disabled, choose Set Capability from the Network Port
Parameters menu.
The Set Capability menu appears.
5. Choose the desired LAN operation mode (10BaseT half duplex, 10BaseT full duplex, 100BaseT half duplex, 100BaseT full duplex), by typing the corresponding number and then pressing <Enter>.
Configuring the Serial Port
The serial port can be configured as the main link of the MT120xA to n x 64 kbps networks.
To configure the Serial port:
1. From the Configuration menu, choose Serial Port Configuration.
The Serial Port Configuration menu appears (see
4-22 Configuring the Main Links
Chapter 4 Management from a Terminal
Serial Port Configuration
1. Interface Type > (V35)
2. Connect> (No)
3. Speed (N*64)[1 - 32]... (64)
4. Clock Mode > (DTE)
5. Clock Invert> (No)
6. Control Signals> (Ignore)
>
7. Fragmentation [200 - 1550]... (610)
Please select item <1 to 7>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-23. Serial Port Configuration Menu
2. From the Serial Port Configuration menu, configure the following parameters:
Interface Type:
V35
for V.35
X21
for X.21
EIA-530
for RS-530
EIA-530-A
for RS-530A
Connect:
Yes
(port is connected)
No
(port is not connected).
Speed (port data rate, in rates of n x 64 kbps between 64 and 2048 kbps)
Clock Mode:
DTE
(MT120xA transmit and receive timing is according to clock received from the connected communication equipment)
DCE
(MT120xA provides the transmit and receive clock signals, derived from its internal oscillator, to the communication equipment connected to the link).
Clock Invert (In a few rare cases, even though the Serial uplink is correctly configured, there are problems with line synchronization. In this case, inverting the clock often resolves the line synchronization problem.
Yes
(Invert the clock)
No
(Clock is not inverted).
Control Signals (Available only in DTE clock mode. Determines whether
MT120xA monitors the control signals. For example, if the CD signal is not
Configuring the Main Links 4-23
Chapter 4 Management from a Terminal sensed, MT120xA will know there is a problem with the line connection and will trigger the TRUNK IS DOWN alarm.):
Ignore
(Do not monitor the control signals)
Obey
(Monitor the control signals).
Fragmentation (MT120xA chops up the Ethernet packets directed from the
LAN to the Serial uplink. This parameter specifies the size of the choppedup Ethernet packets. Specify a value between 200 and 1550.)
4.8 Configuring the Voice Ports
It is recommended to configure the voice port in the following order:
1. Configure the voice port at a bundle level (frame size, destination IP, destination bundle, packetizing interval, TOS parameters, compression method, fax relay, VLAN parameters).
2. Configure the voice port at the physical level (framing mode, restoration time, clock source, interface type, idle code, signaling type, signaling profile).
3. Configure the timeslots (voice or data, mapping to specific bundles, routing to a remote Voice Mux Gateway’s ports and timeslots).
Configuring Bundles
Voice timeslots are grouped together into bundles. MT120xA supports 12 bundles, with a maximum of 31 timeslots per bundle.
Before configuring bundles, you must add at least one bundle.
To add a bundle for the T1/E1 port (MT1200A, MT1207A and MT120xAE):
1. From the Configuration menu (
), choose Voice Configuration.
The Voice Configuration menu appears (
4-24 Configuring the Voice Ports
Chapter 4 Management from a Terminal
Voice Configuration
1. Bundles Parameters>
2. T1 Parameters>
3. Distribution Of Framer Time Slots>
>
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-24. Voice Configuration Menu
2. From the Voice Configuration menu, choose Bundles Parameters.
The Bundles Parameters menu appears (see
>
Bundles Parameters
1. Display Bundles[]
2. Bundle Configuration >
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-25. Bundles Parameters Menu
3. From the Bundles Parameters menu, choose Bundle Configuration.
The Bundle Configuration menu appears (see
Configuring the Voice Ports 4-25
Chapter 4 Management from a Terminal
>
Bundle Configuration
1. Add Bundle[1 - 12]... (1)
2. Delete Bundle[1 - 12]... (1)
3. Edit Bundle>
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-26. Bundle Configuration Menu
4. From the Bundle Configuration menu, choose Add Bundle.
5. Type the number to assign to the bundle you are adding and then press
<Enter>
. The bundle number must be in the range from 1 to 12.
To add a bundle to an FXS port (MT1201A only):
1. From the Main Menu (Figure 4-2), choose Configuration.
The Configuration menu (
>
Configuration
1. System>
2. Switch Lan Configuration>
3. FXS Configuration>
4. Serial Port Configuration>
Please choose item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-27. Configuration Menu for MT1201A
2. From the Configuration menu (
The FXS Configuration menu appears (see
4-26 Configuring the Voice Ports
Chapter 4 Management from a Terminal
>
FXS Configuration
1. Bundles Parameters>
2. Timeouts >
3. Ringer Profile >
4. Ports Distribution>
5. Port Configuration>
Please select item <1 to 5>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-28. FXS Configuration Menu
3. From the FXS Configuration menu, choose Bundles Parameters.
The Bundles Parameters menu appears (see
4. Continue using the procedure above for the T1/E1 voice port.
To configure an existing bundle on an T1/E1 port (MT1200A, MT1207A and
MT120 xAE):
1. From the Bundle Configuration menu (see
Figure 4-26
), choose Edit Bundle.
The Edit Bundle menu appears (see
Figure 4-29
).
Edit Bundle
1. Enter Bundle Number[1 - 12]... (1)
2. Connect> (Yes)
3. Function> (TDMoIP)
4. Max Bytes In Multiplexed Frame[100 - 1461]... (500)
5. Destination IP... (0.0.0.0)
6. Destination Bundle[1 - 30]... (1)
7. Packetizing Interval (msec)[10 - 90]... (30)
8. Connectivity Parameters>
9. TOS Parameters>
10. Voice Parameters>
11. VLAN Parameters>
12. Bundle Name... ()
>
Please select item <1 to 12>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-29. Edit Bundle Menu for MT120xA with T1/E1 Port
Configuring the Voice Ports 4-27
Chapter 4 Management from a Terminal
2. From the Edit Bundle menu, type 1, press <Enter>, and then enter the number of the bundle you want to configure.
3. Configure the following parameters of the selected bundle:
Connect:
Yes
(bundle is connected)
No
(bundle is not connected)
Function:
TDMoIP
(Uses the TDMoIP protocol to transmit the voice and data over the network. For IP-based networks, this option must be used.)
AAL2oMPLS
(Uses the MPLS protocol to transmit the voice and data over the network. This option, which requires less bandwidth than
TDMoIP, may be used for non-IP networks.)
Max Bytes In Multiplexed Frame (size of a multiplexed TDMoIP frame in bytes):
100
to 1461 bytes
Destination IP (IP address of the destination
MT120xA or Voice Mux Gateway group)
Destination Bundle (number of the destination bundle of the group with the IP address specified in the previous step)
1
to 30
Packetizing Interval (msec) (time interval allocated for the TDMoIP frame aggregation):
10
to 90 msec
Connectivity parameters (keep-alive messages configuration)
>
Connectivity Parameters
1. Connectivity-packet rate (sec)[1 - 60]... (60)
2. Connectivity timeout cycles[1 - 5]... (3)
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-30. Connectivity Parameters Menu
4-28 Configuring the Voice Ports
Chapter 4 Management from a Terminal
Note
MT120xA constantly monitors the status of all connected bundles, by sending 64-byte keep-alive messages to the remote device. Connectivity is confirmed by receiving a reply from the remote unit. This process is similar to pinging remote IP hosts. If a reply is not received, usually due to a main link failure, MT120xA disconnects the bundle and generates the BUNDLE
IS OOS (Out Of Service) alarm. When the BUNDLE IS OOS alarm is generated, MT120xA notifies the PBX by sending “all 1s” string (CCS signaling) or the OOS message (CAS signaling) on all timeslots of the disconnected bundle. This notification allows the attached PBX to stop transmitting over a faulty link and to switch to a backup link.
You can specify the following connectivity parameters:
Connectivity packet rate
(frequency of sending the keep-alive packets, from one packet per 1 second to one packet per 60 seconds)
Connectivity timeout cycles
(number of attempts within which
MT120xA expects to receive at least one reply from the remote device).
For example, if you set the connectivity packet rate to 60 seconds and connectivity timeout to 3, MT120xA disconnects a bundle from which it did not receive at least one reply within 180 seconds.
•
In IP networks, where delays are more common, it is recommended to set the connectivity parameters to their maximum values.
TOS Parameters (standard Type of Service parameters of the outgoing IP frames):
>
TOS Parameters
1. Precedence > (Routine)
2. Delay > (Normal)
3. Throughput > (Normal)
4. Reliability> (Normal Reliability)
Please select item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-31. TOS Parameters Menu
Precedence
(Routine, Priority, Immediate, Flash, Flash Override,
Critic/Ecp, Internetwork Control, Network Control)
Delay
(Normal, Low)
Throughput
(Normal, High)
Configuring the Voice Ports 4-29
Chapter 4 Management from a Terminal
Reliability
(Normal, High).
Voice Parameters (see
Voice Parameters
1. Coder/Rate (kbps)> (G.723.1/6.4)
2. Volume> (0 dB)
3. Fax/Modem>
4. MF Parameter>
5. Custom Tone Detection>
6. Echo Canceller> (Enable)
7. Coding> (A-Law)
>
Please select item <1 to 7>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-32. Voice Parameters Menu for T1/E1 Port
Coder/Rate (compression algorithm and corresponding rate):
G.723.1/6.4
(as per G.723.1 requirements at 6.4 kbps)
G.723.1/5.3
(as per G.723.1 requirements at 5.3 kbps)
G.729A/8
(as per G.729 A requirements at 8 kbps)
G.711 a LAW
(as per G.711 requirements, A-law companding)
G711 u LAW
(as per G.711 requirements, µ-law companding).
Volume (sets the volume gain transmitted from the DSPs). For example, if the gain received from the voice switch/PBX is very low, you may set the volume to +3 dB, thereby amplifying the TX voice volume without the need to change the configuration of the voice switch. -6 dB to +6 dB in steps of 1 dB.
Fax/Modem (configure fax and modem settings)
Modem
–enable/disable the modem signal identification and relay
Fax
–enable/disable the fax signal identification and relay
Fax Rate
–set the fax transmission rate (in kbps): 4.8, 9.6, 14.4.
MF Parameter (configure MF parameters)
MF Relay
–enable/disable MF tone relay
Minimum Pulse Width
–minimum pulse width of the MF tone to be detected and relayed: 30 to 32676 msec
Minimum Power Level
–minimum power level of the MF tone to be detected and relayed: 0 to –35 dBm.
4-30 Configuring the Voice Ports
Chapter 4 Management from a Terminal
Note
Compelled
–enable/disable Multi-frequency compelled (MFC). If your
PBX uses MFC, set this parameter to Enable.
Custom Tone Detection (set tone detection parameters)
Tone Detection–enable/disable tone detection. Enable if the PBX/Voice switch checks the line quality before establishing a call on a specific timeslot. The line is checked by sending a 2000 Hz tone on the line.
Since MT120xA compresses the Voice, the tone is usually also compressed and as a result the PBX may fail to detect the originated
2000 Hz tone. When Tone Detection is enabled, upon detecting a
2000 Hz tone, the DSP sends a message to the remote DSP to generate this specific 2000 Hz tone (tone relaying).
Select Tone–the frequency of the tone to be detected: 2000 Hz.
Echo Canceller (disable the built-in echo canceller, which provides up to
16 msec delay).
If you have an external echo canceller on your telephone network, disable the built-in MT120xA DSP echo canceller.
Coding (set the coding used by your PBX):
A-Law
(usually used for E1)
U-Law
(µ-Law, usually used for T1)
If you intend to change the voice parameters, it is recommended to disconnect a bundle before configuring it. The bundle must be disconnected at the local and remote sites. If you do not disconnect the bundle, you must reset the local and remote voice interfaces carrying the links whose timeslots belong to the bundle. The voice interfaces must be reset after you complete configuring the voice parameters.
VLAN Parameters (enable/disable virtual LAN tagging, specify VLAN number, and its priority):
>
VLAN Parameters
1. Vlan Exist > (Yes)
2. Vlan Id [26 - 4094]... (26)
3. Vlan Priority [0 - 7]... (1)
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-33. VLAN Parameters Menu
Configuring the Voice Ports 4-31
Chapter 4 Management from a Terminal
Vlan Number: 26 to 4094
Vlan Priority: 0 (minimum) to 7 (maximum).
Bundle Name (assign an identification name to a bundle).
To configure an existing bundle on an FXS port (MT1201A only):
1. From the Bundle Configuration menu (see
The Edit Bundle menu appears.
Edit Bundle
1. Enter Bundle Number[1 - 4]... (1)
2. Connect> (Yes)
3. Function> (TDMoIP)
4. Max Bytes In Multiplexed Frame[100 - 1472]... (500)
5. Destination IP... (172.17.172.171)
6. Destination Type> (PBX)
7. Destination Bundle[1 - 60]... (1)
8. Packetizing Interval (msec)[10 - 90]... (30)
9. Connectivity Parameters>
10. TOS Parameters>
11. Voice Parameters>
12. VLAN Parameters>
13. Bundle Name... ()
>
Please select item <1 to 13>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-34. Edit Bundle Menu for MT1201A
2. From the Edit Bundle menu, type 1, press <Enter>, and then enter the number of the bundle you want to configure.
3. Configure the following parameters of the selected bundle:
Connect:
Yes
(bundle is connected)
No
(bundle is not connected)
Function:
TDMoIP
(Uses the TDMoIP protocol to transmit the voice and data over the network. For IP-based networks, this option must be used.)
AAL2oMPLS
(Uses the MPLS protocol to transmit the voice and data over the network. This option, which requires less bandwidth than
TDMoIP, may be used for non-IP networks.)
Max Bytes In Multiplexed Frame (size of a multiplexed TDMoIP frame in bytes):
100
to 1461 bytes
Destination IP (IP address of the destination MT120xA or Voice Mux
Gateway group)
4-32 Configuring the Voice Ports
Note
Chapter 4 Management from a Terminal
Destination Type (The type of device connected to this bundle)
PBX
Phone
Destination Bundle (number of the destination bundle of the group with the IP address specified in the previous step)
1
to 30
Packetizing Interval (msec) (time interval allocated for the TDMoIP frame aggregation):
10
to 90 msec
Connectivity parameters (keep-alive messages configuration)
MT120xA constantly monitors the status of all connected bundles, by sending 64-byte keep-alive messages to the remote device. Connectivity is confirmed by receiving a reply from the remote unit. This process is similar to pinging remote IP hosts. If a reply is not received, usually due to a main link failure, MT120xA disconnects the bundle and generates the BUNDLE
IS OOS (Out Of Service) alarm. When the BUNDLE IS OOS alarm is generated, MT120xA notifies the PBX by sending “all 1s” string (CCS signaling) or the OOS message (CAS signaling) on all timeslots of the disconnected bundle. This notification allows the attached PBX to stop transmitting over a faulty link and to switch to a backup link.
You can specify the following connectivity parameters:
Connectivity packet rate
(frequency of sending the keep-alive packets, from one packet per 1 second to one packet per 60 seconds)
Connectivity timeout cycles
(number of attempts within which
MT120xA expects to receive at least one reply from the remote device).
For example, if you set the connectivity packet rate to 60 seconds and connectivity timeout to 3, MT120xA disconnects a bundle from which it did not receive at least one reply within 180 seconds.
•
In IP networks, where delays are more common, it is recommended to set the connectivity parameters to their maximum values.
TOS Parameters (standard Type of Service parameters of the outgoing IP frames):
Precedence
(Routine, Priority, Immediate, Flash, Flash Override,
Critic/Ecp, Internetwork Control, Network Control)
Delay
(Normal, Low)
Throughput
(Normal, High)
Reliability
(Normal, High).
Voice Parameters
Configuring the Voice Ports 4-33
Chapter 4 Management from a Terminal
>
Voice Parameters
1. Coder/Rate (kbps)> (G.723.1/6.4)
2. Fax/Modem>
3. MF Relay> (Disable)
4. VAD> (Conservative)
5. Echo Canceller> (Enable)
Please select item <1 to 5>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-35. Voice Parameters Menu for FXS Port (MT1201A)
Coder/Rate (compression algorithm and corresponding rate):
G.723.1/6.4
(as per G.723.1 requirements at 6.4 kbps)
G.723.1/5.3
(as per G.723.1 requirements at 5.3 kbps)
G.729A/8
(as per G.729 A requirements at 8 kbps)
G.711 a LAW
(as per G.711 requirements, A-law companding)
G711 u LAW
(as per G.711 requirements, µ-law companding).
Fax/Modem (configure fax and modem settings)
Modem
–enable/disable the modem signal identification and relay
Fax
–enable/disable the fax signal identification and relay
Fax Rate
–set the fax transmission rate (in kbps): 4.8, 9.6, 14.4.
MF Parameter (configure MF parameters)
MF Relay
–enable/disable MF tone relay
Minimum Pulse Width
–minimum pulse width of the MF tone to be detected and relayed: 30 to 32676 msec
Minimum Power Level
–minimum power level of the MF tone to be detected and relayed: 0 to –35 dBm.
Compelled
–enable/disable Compelled.
Echo Canceller (disable the built-in echo canceller, which provides up to
16 msec delay).
If you have an external echo canceller on your telephone network, disable the built-in MT120xA DSP echo canceller.
4-34 Configuring the Voice Ports
Chapter 4 Management from a Terminal
VLAN Parameters (enable/disable virtual LAN tagging, specify VLAN number, and its priority):
Vlan Number: 26 to 4094
Vlan Priority: 0 (minimum) to 7 (maximum).
Bundle Name (assign an identification name to a bundle).
Configuring the T1 Voice Port (MT1200A and MT1207A)
MT1200A and MT1207A each provide a single T1 port, which receives voice traffic from the PBX.
To configure the T1 port:
1. From the Voice Configuration menu (see
The T1 Parameters menu appears (see
T1 Parameters
1. Connect> (Yes)
2. Clock Mode> (Lbt (Local))
3. Frame> (Esf)
4. Interface Type> (Dsu)
5. Line Code> (B8ZS)
6. Line Length> (0-133 Feet)
>
7. Restoration Time> (1 Second (Fast))
8. Idle Code[1 - ff]... (44)
9. Signaling> (Robbed bit MF)
10. Profile[1 - 5]... (1)
Please select item <1 to 10>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-36. T1 Parameters Menu
2. From the T1 Parameters menu, configure the following T1 parameters:
Connect:
Yes
(T1 link is enabled)
No
(T1 link is disabled).
Clock Mode:
Lbt
(derived from the received T1 signal)
Internal
(received from the MT120xA internal oscillator).
Frame (T1 framing mode):
Esf
(24 frames per multiframe)
SF (D4)
(12 frames per multiframe).
Interface Type:
Configuring the Voice Ports 4-35
Chapter 4 Management from a Terminal
Note
DSU
(DSU interface)
CSU
(CSU interface).
Line Code (line code and zero suppression method used by the port):
B8ZS
(B8ZS coding)
AMI
(AMI coding).
Line Length (DSU mode only, length of a cable in feet between the
MT120xA T1 port connector and the network access point):
0–133 Feet
133–266 Feet
266–399 Feet
399–533 Feet
533–655 Feet.
Rx Sensitivity (CSU mode only, maximum attenuation of the Rx signal that can be compensated for by the port Rx path, to obtain BER performance required by the standards):
Low
(-30 dB) (-30 dB relative to the nominal transmit level of 0 dB)
High
(-36 dB) (-36 dB relative to the nominal transmit level of 0 dB).
Tx Gain Level (CSU mode only, relative T1 output transmit level):
0 dB
(no attenuation)
7.5 dB
(attenuation of 7.5 dB relative to the nominal transmit level)
15 dB
(attenuation of 15 dB relative to the nominal transmit level)
22.5 dB
(attenuation of 22.5 dB relative to the nominal transmit level)
Restoration Time (time required for the E1 port to return to normal operation after sync loss):
1 Second
(after 1 second, fast)
10 Second
(as per requirements of AT&T TR-62411)
CCITT
(as per requirements of ITU-T Rec.G.732).
Idle Code (code transmitted to fill unused timeslots in the E1 frames): 00 to
ff
.
Signaling (select a signaling mode for the T1 links):
Robbed Bit MF
CCS
.
Profile (select the signaling profile). When operating with RBMF signaling, it is necessary to assign a signaling profile to the T1 link. The profile must be compatible with the PBX signaling (signaling profile configuration is
explained in Configuring Signaling Profiles, above).
•
If you intend changing the T1 signaling configuration, it is recommended to disconnect a bundle to which the T1 timeslots are assigned before configuring the signaling mode. The bundle must be disconnected at the local and remote sites. If
4-36 Configuring the Voice Ports
Chapter 4 Management from a Terminal
you do not disconnect the bundle, you must reset the local and remote voice modules carrying the T1 links after you complete configuring the T1 signaling.
To configure the T1 timeslots:
1. From the Voice Configuration menu (see
Framer Time Slots
.
The Distribution Of Framer Time Slots menu appears (see
>
Distribution Of Framer Time Slots
1. Display Time Slots Configuration[]
2. Configure Time Slots>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-37. Distribution Of Framer Time Slots Menu
2. From the Distribution Of Framer Time Slots menu, choose Configure Time
Slots
.
The Configure Time Slots menu appears (see
Configure Time Slots
1. Update from Time Slot[1 - 31]... (1)
2. To TimeSlot[1 - 31]... (1)
3. Type> (N.C)
4. Bundle[1 - 12]... (1)
5. Destination Port ID[1 - 4]... (1)
6. Destination Time Slot ID[1 - 31]... (1)
>
7. Update Time Slot
Please select item <1 to 7>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-38. Configure Time Slots Menu
Configuring the Voice Ports 4-37
Chapter 4 Management from a Terminal
Note
Note
3. From the Configure Time Slots menu, configure the following parameters:
Define the range of timeslots you want to configure:
Set Update from Time Slot to the number of the first timeslot in the range.
Set To Time Slot to the number of the last timeslot in the range.
To configure a single timeslot, set both parameters to the number of the timeslot you want to configure.
Set the timeslot type by choosing Type:
N.C
. (timeslot is not connected)
Voice
(timeslot transmits voice)
HDLC
(timeslot transmit data, for example, signaling information).
Assign the timeslot(s) to a bundle on the local MT120xA, by choosing
Bundle
, and entering a bundle number.
Specify a Voice Mux Gateway destination port, by choosing Destination
Port
, and entering a port number.
•
For applications when MT120xA operates opposite remote MT120xA, the destination port ID is always 1.
Define the destination timeslots to which the local timeslots are routed. You have to specify only a starting timeslot; the rest of the destination timeslots are configured automatically in accordance with the number of timeslots set in steps 1 and 2 of the Time Slot Configuration (see
a destination timeslot, choose Destination Time Slot ID and then enter the number of the first timeslot in the range, on the remote MT120xA or
Voice Mux Gateway.
Save the changes that you made to the timeslots, by choosing Update Time
Slot
.
•
Make sure to save the changes that you have made to the timeslot configuration.
4. Check the resulting timeslot configuration by choosing Display Time Slots
Configuration
from the Distribution Of Framer Time Slots menu.
The Display Time Slots Configuration screen appears (see
4-38 Configuring the Voice Ports
Chapter 4 Management from a Terminal
Display Time Slots Configuration
Ts# Type Bundle Dest Port Dest Ts
1 N.C 0 1 0
2 Voice 1 4 1
| 3 Voice 1 4 2 v 4 Voice 1 4 3
5 Voice 1 4 4
6 N.C 0 1 0
7 N.C 0 1 0
8 N.C 0 1 0
9 N.C 0 1 0
10 N.C 0 1 0
>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 4-39. Display Time Slots Configuration Screen
Configuring the E1 Voice Port (MT120 xAE)
MT120 xAE provides a single E1 port, which receives voice traffic from the PBX.
To configure the E1 port:
1. From the Voice Configuration menu (see
The E1 Parameters menu appears (see
E1 Parameters
1. Connect> (No)
2. Frame> (G.732S)
3. Interface Type> (Ltu)
4. Restoration Time> (1 Second (Fast))
5. Clock Source> (Lbt (Local))
6. Idle Code[1 - ff]... (ff)
>
7. Profile[1 - 5]... (1)
Please select item <1 to 7>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-40. E1 Parameters Menu
2. From the E1 Parameters menu, configure the following E1 parameters:
Connect:
Configuring the Voice Ports 4-39
Chapter 4 Management from a Terminal
Note
Yes
(E1 link is enabled)
No
(E1 link is disabled).
Frame (E1 framing mode):
G.732N
(256N multiframe, 2 frames per multiframe, CRC-4 function disabled)
G.732N-CRC4
(256N multiframe, 2 frames per multiframe, CRC-4 function enabled)
G.732S
(256S multiframe, 16 frames per multiframe, CRC-4 function disabled)
G.732S-CRC4
(256S multiframe, 16 frames per multiframe, CRC-4 function enabled).
•
By choosing an E1 framing mode, you also set the signaling mode:
• G.732N/G.732N-CRC4 framing – CCS signaling
• G.732S/G.732S-CRC4 framing – CAS signaling.
Interface Type (maximum attenuation of the Rx signal that can be compensated for by the port Rx path, to obtain BER performance required by the standards):
Ltu
(maximum attenuation of 43 dB, relative to the nominal transmit level of 0 dB, operates at longer ranges)
Dsu
(maximum attenuation of 12 dB, relative to the nominal transmit level of 0 dB).
Restoration Time (time required for the E1 port to return to normal operation after sync loss):
1 Second
(after 1 second, fast)
10 Second
(as per requirements of AT&T TR-62411)
CCITT
(as per requirements of ITU-T Rec.G.732).
Clock Source:
Lbt
(derived from the received E1 signal)
Internal
(received from the MT120xA internal oscillator).
Idle Code (code transmitted to fill unused timeslots in the E1 frames): 00 to
ff
.
Signaling profile for the CAS signaling (1 to 5). The profile must be compatible with the PBX signaling (signaling profile configuration is explained in the
Configuring Signaling Information
4-40 Configuring the Voice Ports
Chapter 4 Management from a Terminal
Note
•
If you intend changing the E1 signaling configuration, it is recommended to disconnect a bundle to which the E1 timeslots are assigned before configuring the signaling mode. The bundle must be disconnected at the local and remote sites. If you do not disconnect the bundle, you must reset the local and remote voice interfaces carrying the E1 links after you complete configuring the E1 signaling.
To configure the E1 timeslots:
1. From the Voice Configuration menu (see
Framer Time Slots
.
The Distribution Of Framer Time Slots menu appears (see
2. Continue using the same procedure as for the T1 timeslots. For more information, see
Configuring the FXS Voice Ports (MT1201A only)
MT1201A provides four analog FXS voice ports. If the FXS ports connect to a telephone handset, the FXS ports need to be configured to function like the PBXs at the location. The DSP on the MT1201A is capable of producing all of the tones and signals that a PBX usually sends to a telephone handset.
To configure an FXS port:
1. From the Configuration menu (
The FXS Configuration menu appears (see
2. From the FXS Configuration menu, choose Timeouts.
The Timeouts menu appears (see
>
Timeouts
1. Ring Timeout (sec)[60 - 600]... (120)
2. On hook duration in Flash (mSec)[10 - 2000]... (700)
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-41. Timeouts Menu
3. Set the timeouts:
Ring Timeout
(the number of seconds for which MT120xA waits for a telephone handset to be answered)
Configuring the Voice Ports 4-41
Chapter 4 Management from a Terminal
On hook duration in Flash
(the duration of Flash—the Flash key on the phone keypad—in msec. Different PBXs have different Flash durations, so you can configure this parameter according to the PBX in use. The Flash is a fast ON HOOK and OFF HOOK operation.)
4. From the FXS Configuration menu, choose Ringer Profile.
The Ringer Profile menu appears (see
>
Ringer Profile
1. Period #1: Ring (100 mSec)[1 - 50]... (10)
2. Period #1: Silence (100 mSec)[1 - 50]... (30)
3. Period #2: Ring (100 mSec)[0 - 50]... (0)
4. Period #2: Silence (100 mSec)[0 - 50]... (0)
Please select item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-42. Ringer Profile menu
5. The ringer profile determines the ring tone. Use this menu to configure the ring tone to match the standard ring tone at the location. To define a ringer profile, set the first two, or all four, parameters (specify 0 to 50, in units of 100 mSec):
Period #1 Ring
(the length of the first ring tone)
Period #1 Silence
(the length of the first silence period; for locations that have only one ring tone, specify the period of silence between rings; for locations that have a double ring tone, specify the silence between the two ring tones)
Period #2 Ring
(the length of the second ring tone)
Period #2 Silence
(the length of the silence between each set of double ring tones).
6. From the FXS Configuration menu, choose Port Configuration.
The Port Configuration menu appears (see
4-42 Configuring the Voice Ports
Chapter 4 Management from a Terminal
>
Port Configuration
1. Port Number> (Port #1)
2. Gains>
3. FXS Signaling Parameters[]>
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-43. Port Configuration Menu
7. Choose Port Number and then select the number of the port you want to configure.
8. Choose Gains and then set the following gains:
TX gain
(the gain to apply to the transmit signals (signals sent out from the
MT120xA); commonly used to amplify a weak signal or reduce a signal that is too strong)
RX gain
(the gain to apply to receive signals (signals transmitted from the handset or PBX to the MT120xA)).
9. Choose FXS Signaling Parameters.
The FXS Signaling Parameters screen appears (see
Configuring the Voice Ports 4-43
Chapter 4 Management from a Terminal
>
FXS Signaling Parameters >Port #1
A Bit B Bit C Bit D Bit
ON HOOK 0 1 0 1
OFF HOOK 1 1 0 1
1. 0
2. 1
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 4-44. FXS Signaling Parameters Screen
10. Set the A, B, C and D bits that make up the on-hook and off-hook signals. To set a value, press <Tab> to select the value to be changed, and then choose the appropriate menu option to make the desired setting.
To configure the FXS timeslots:
1. From the FXS Configuration Menu (see
Distribution
.
The Ports Distribution menu appears (see
>
Ports Distribution
1. Display Time Slots Configuration[]
2. Configure Time Slots>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 4-45. Ports Distribution Menu
2. Continue using the same procedure as for the T1 timeslots. For more information, see
4-44 Configuring the Voice Ports
Chapter 4 Management from a Terminal
4.9 Configuring the User Ethernet Port
The MT120xA has two Ethernet ports. One port may be used to connect the main link; the other Ethernet port can be used to connect the local user network. The
MT120xA includes a switch that routes the voice and data intelligently.
To configure the user Ethernet port:
1. From the Switch Lan Configuration menu (see
Configuration
.
The User Port Configuration menu appears. This menu is identical to the
Network Port Configuration menu (see
2. Configure the user Ethernet port. The procedure is the same as configuring the
main link network port (see Configuring the Ethernet Network Port, above).
4.10 Restoring Default Settings
You can restore the voice port settings of the MT120xA to the factory default settings. Restoring the defaults erases defined bundles and assigned timeslots. The system parameters are not affected.
To restore the MT120xA to the defaults:
1. From the System menu (see
MT120xA displays the following message:
Are you sure you want to initialize to default configuration(Y/N)?
2. Type Y, and then press <Enter>.
MT120xA restores configuration of the voice port(s) to the default settings.
4.11 Resetting the MT120xA
The MT120xA management software allows you to re-initialize the main board
CPU of the unit.
To reset the MT120xA components:
1. From the System menu, choose Reset Unit.
MT120xA displays the following message:
Are you sure you want to reset the MT120xA ? Press
Y/N
2. Type Y, and then press <Enter>.
The unit is re-initialized; its active software is decompressed and loaded into the RAM.
Resetting the MT120xA 4-45
Chapter 4 Management from a Terminal
4-46 Resetting
Chapter 5
Configuring a Typical
Application
This chapter gives detailed instructions for configuring MT120xA for a typical application in which two MT120xA units operate opposite a central Voice Mux
Gateway unit over an IP network.
5.1 Application Requirements
illustrates a typical TDM application, in which two MT120xA units
operate opposite a central Voice Mux Gateway over an IP network.
172.17.15.20
10/100BaseT
E1
PBX
PSTN
Vmux-110
Central Site
E1
E1
172.17.15.10
10/100BaseT
IP
Network
Vmux-2100
172.17.15.11
10/100BaseT
E1
Vmux-110
PBX
Figure 5-1. Typical Application
172.17.15.21
The following network requirements exist:
• Two E1 trunks are transmitted by the central Voice Mux Gateway over IP network to two remote MT120xA units. Both E1s belong to the same group.
• Each local timeslot carries voice. It is routed to the same timeslot of the corresponding E1 at the remote site
• CAS signaling or CCS signaling
• G.732S or G.732N framing mode, without CRC-4 bits generation
• G.729 A voice compression
• Loopback timing
• Fax relay at 9.6 kbps.
Application Requirements 5-1
Chapter 5 Configuring a Typical Application
5.2 Outline of Configuration Procedure
The recommended configuration procedure for this application includes the following steps:
1. Configure the local Voice Mux Gateway.
2. Configure the IP host parameters for both remote MT120xA units via an ASCII terminal connection.
3. Install the two MT120xA units at their locations.
4. Configure one of the MT120xA units.
5. On the management station, save the configuration file (cnfg110.dat) of the configured MT120xA unit. This is done by running a TFTP client application on the management station.
6. Download the configuration file to the second MT120xA unit. This is done by running a TFTP client application on the management station.
7. Update the relevant parameters on the second MT120xA unit.
5.3 Configuring the Local Voice Mux Gateway
This section provides only a summary of the parameters necessary for the voice E1 configuration of the central Voice Mux Gateway. Refer to appropriate sections of the
Voice Mux Gateway Installation and Operation Manual
for more detailed instructions.
To configure the central Voice Mux Gateway:
1. Assign the 172.17.15.11 IP address to the E1 group 1.
2. Add two bundles and configure them as follows:
Connect – Yes
Function – TDMoIP
Max Bytes In Multiplexed Frame – 500
Destination IP:
Bundle 1 – 172.17.15.20
Bundle 2 – 172.17.15.21
Destination Bundle – 1
Packetizing Interval – 30
Coder Rate – G723.1/6.4
Fax/modem – Enable at 9.6 kbps.
3. Configure external E1 parameters:
Connect – Yes
Frame – G.732S
Restoration – CCITT
5-2 Configuring the Local Voice Mux Gateway
Chapter 5 Configuring a Typical Application
Clock Source – Lbt
Interface Type – Dsu
Idle Code – 7E
Profile – 1.
4. Assign timeslots of the first external E1:
Update from Time Slot – 1
To Time Slot – 31
Type – Voice
Bundle – 1
Destination Port ID – 1
Destination Time Slot ID – 1.
5. Configure timeslots of the second external E1 to the same parameters, except for the following:
Assign the timeslots to bundle 2
Now you can proceed with configuration of remote MT120xA units.
5.4 Configuring MT120xA for Operation with CAS
Signaling
Note
You must save the selected values by updating the MT120xA database. If the database is not updated, MT120xA discards all the user settings when it is reset. You can save selected values at any stage of the configuration procedure.
Configuring System Parameters
To configure the MT120xA system parameters:
1. Configure an ASCII terminal to: 115.2 kbps, one start bit, eight data bits, no parity, one stop bit, no flow control, VT100 emulation.
2. Connect the terminal to the first MT120xA RJ-45 CONTROL port.
3. Initiate the control session by entering the user name and password.
4. Display the Host IP menu and enter the IP address (172.17.15.20), its subnet mask and default gateway values (Main Menu > Configuration > System >
Management
> Host IP).
5. Repeat step 2 to step 4 for the second MT120xA unit, and assign the
172.17.15.21 IP address to it.
Note
Most of the configuration procedures are performed on one of the units, except for the defining IP parameters of the second MT120xA.
Configuration procedure is divided into three main stages:
• Defining system parameters.
• Configuring main link parameters.
• Setting voice E1 parameters.
Configuring MT120xA for Operation with CAS Signaling 5-3
Chapter 5 Configuring a Typical Application
The rest of the configuration procedure refers to the first unit. Information applicable to both units (or only to the second MT120xA) is explicitly identified.
6. Display the Signal Profile Configuration menu, enter a desired signaling system profile number (1) and configure it according to the system used by the PBX connected to the E1 port (Main Menu > Configuration > System >
Management
> Signaling Configuration> Signaling Profile Configuration).
Configuring Voice E1 Parameters
Configuring the voice E1 parameters:
1. Display the Bundle Configuration menu, and add bundle 1 to the system
(Main Menu > Configuration > E1 Voice Configuration > Bundles
Parameters
> Bundle Configuration > Add Bundle).
2. Display the Edit Bundle menu, and configure the bundle 1 parameters to the following values (Main Menu > Configuration > E1 Voice Configuration >
Bundles Parameters
> Bundle Configuration > Edit Bundle):
Connect – Yes
Function – TDMoIP
Max Bytes In Multiplexed Frame – 500
Destination IP – 172.17.15.11
Destination Bundle – 1
Packetizing Interval – 30
Coder/Rate – G723.1A/6.4
Fax/Modem – Enable at 9.6 kbps.
3. Display the E1 Parameters menu, and set the E1 port parameters to the following values (Main Menu > Configuration > E1 Voice Configuration >
E1 Parameters
):
Connect – Yes
Frame – G.732S
Restoration – CCITT
Clock Source – Lbt
Interface Type –Dsu
Idle Code – 7E
Profile – 1.
4. Display the Time Slot Configuration menu, and configure the timeslots belonging to the external port 1 of group 1 (Main Menu > Configuration >
E1 Voice Configuration
> Distribution Of Framer Time Slots > Time Slot
Configuration
):
Update from Time Slot – 1
To Time Slot – 31
Type – Voice
Bundle – 1
5-4 Configuring MT120xA for Operation with CAS Signaling
172.17.15.11
Chapter 5 Configuring a Typical Application
Destination Port ID – 1
Destination Time Slot ID – 1.
Note
1
MT120xA displays timeslot 16 as ‘Not Connected’ (NC), because it carries CAS signaling information.
5. Update the timeslot database from the Time Slot Configuration menu.
summarizes the external E1 bundle and timeslot configuration of the
local and remote units.
30 voice timeslots routed to bundle 1, destination port 1
Bundle 1
Destination IP - 172.17.15.20
Bundle 1
Destination IP - 172.17.15.11
30 voice timeslots routed to bundle 1, destination port 1
Remote Vmux-110
172.17.15.20
Local Vmux-2100
2
30 voice timeslots routed to bundle 2, destination port 1
Bundle 2
Destination IP - 172.17.15.21
Bundle 1
Destination IP - 172.17.15.11
172.17.15.21
30 voice timeslots routed to bundle 1, destination port 2
Remote Vmux-110
Figure 5-2. E1 Bundle and Timeslot Configuration
Transferring Database to the Second MT120xA
To transfer the database to the second MT120xA:
1. Upload the cnfg110.dat file from the first MT120xA to the management station via the TFTP protocol.
2. Download the cnfg110.dat file to the second MT120xA via the TFTP protocol.
Note
3. Establish a Telnet connection to the second MT120xA unit.
4. Display the Time Slot Configuration menu and set the Destination Port ID parameter to 2.
5. Update the second MT120xA database by typing @.
Now both remote MT120xA units are ready for operation.
The host IP and the main link values do not change when you download the new configuration and update the database.
5.5 Configuring MT120xA for Operation with CCS
Signaling
Configuration of the MT120xA units operating with the CCS signaling is similar to the configuration for operation with the CAS signaling, except for the following:
1. From E1 Parameters menu, set the E1 framing type to G.732N (Main Menu >
Configuration
> E1 Voice Configuration > E1 Parameters).
2. Display the Time Slot Configuration menu, and configure the timeslots (Main
Menu
> Configuration > E1 Voice Configuration > Distribution Of Framer
Time Slots
> Time Slot Configuration):
Configuring MT120xA for Operation with CCS Signaling 5-5
Chapter 5 Configuring a Typical Application
Update from Time Slot – 1
To Time Slot – 30
Type – Voice
Bundle – 1
Destination Port ID – 1
Destination Time Slot ID – 1.
3. Once you assign all timeslots to carry voice, assign one of them (for example, timeslot 31) to carry signaling information:
Update from Time Slot – 31
To Time Slot – 31
Type – HDLC
Bundle – 1
Destination Port ID – 1
Destination Time Slot ID – 31.
4. Update the timeslot database from the Time Slot Configuration menu.
5. When working with CCS-SS7, you can instruct MT120xA to drop certain amount of fill-in signal units (FISUs) by selecting the appropriate SS7 keep-alive suppression rate (Main Menu > Configuration > System > Management >
Signaling Configuration
> SS7 Keep-Alive Suppression Rate).
6. Set all relevant parameters of the central Voice Mux Gateway in a similar manner (see Voice Mux Gateway installation and operation manual).
5-6 Configuring MT120xA for Operation with CCS Signaling
Chapter 6
Diagnostics
This chapter describes the MT120xA diagnostic functions, which include:
• Tone injection (not on MT1201)
• Local and remote loopbacks (not on MT1201)
• Ping utility.
6.1 Tone Injection
The test tone is a data sequence at a rate of 1 kHz. This data sequence is identical to the data sequence that would have been generated if a 1 kHz signal having a nominal level 0 dBm were applied to the input of the channel speech processor.
The tone should be received clearly by the corresponding subscriber connected to the PBX at the nominal receive level. MT120xA supports tone injection towards the local side only (see
The tone injection is activated individually per timeslot. However, multiple tone injections can be run at the same time. MT120xA allows you to set the tone injection timeout causing the tone relay to deactivate automatically after the desired period of time.
PBX/
Testing Equipment
T1 Framer
~
DSP
Note
MT120xA
Figure 6-1. Local Tone Injection
Before performing tone injection, make sure that the timeslot to which you intend to inject the tone belongs to the properly configured T1/E1 port.
Tone Injection 6-1
Chapter 6 Diagnostics
To activate tone injection:
1. From the Main menu, select Diagnostics.
The Diagnostics menu appears (see
>
Diagnostics
1. Inject Tone test>
2. Local Loop test>
3. Remote Loop test>
4. Display Active tests
5. Ping >
Please select item <1 to 5>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 6-2. Diagnostics Menu
2. From the Diagnostic menu, select Inject Tone Test.
The Inject Tone Test menu appears (see
>
Inject Tone test
1. Time Slot[1 - 31]... (1)
2. Direction> (Local)
3. Time Out(seconds, 0=forever)[0 - 60]... (0)
4. Activate>
Please select item <1 to 4>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 6-3. Inject Tone Menu
3. From the Inject Tone Test menu, perform the following steps to complete the tone injection activation:
Select a timeslot for the tone injection.
Specify the direction of the tone injection:
6-2 Tone
Note
Chapter 6 Diagnostics
Local
(towards the local PBX, see
Define the tone injection timeout (period of time after which the tone injection stops automatically):
0 seconds
(forever) to 60 seconds
Activate the tone injection by choosing Activate, and then selecting Yes from the Activate menu.
Repeat the procedure for all timeslots that you intend to test.
You can display information on all tests running at a time by selecting Display Active
Tests from the Diagnostics menu.
6.2 Loopback Tests
MT120xA supports activation of local and remote loopbacks. The purpose of these tests is to determine the source of a break in the data flow. The loopbacks are activated via voice port (T1, E1 or FXS).
Local Loopback
MT120xA can be set to a local loopback to test the connection between the voice port and the local side PBX. In this mode, data coming from the PBX is looped back to the PBX (see
Main Link
T1 Interface
Framer
Testing
Equipment
Operating in
Internal Clock
M T 1 2 0 x A
Figure 6-4. Local Loopback
To activate a local loopback:
1. Configure the testing equipment to internal clock.
2. From the Diagnostics menu, select Local Loop Test.
The Local Loop Test menu appears (see
3. From the Local Loop Test menu, activate the local loopback by choosing
Activate
, and then choosing Yes from the displayed menu.
Loopback Tests 6-3
Chapter 6 Diagnostics
>
Local Loop test
1. Activate>
Please select item <1 to 1>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 6-5. Local Loop Test Menu
Remote Loopback
MT120xA can be set to a remote loopback to test the internal connection between the voice port and the main link. In this mode, data coming from the IP network is looped back to the network (to the remote side), see
To activate a remote loopback:
1. From the Diagnostics menu, select Remote Loop Test.
The Remote Loop Test menu appears.
2. From the Remote Loop Test menu, activate the remote loopback by choosing
Activate
, and then choosing Yes from the displayed menu.
T1 Interface
Framer
M a in L in k
Main Link
T1 Interface
Framer
Testing
Equipment
PBX
Remote MT120xA Local MT120xA
Figure 6-6. Remote Loopback
Chapter 6 Diagnostics
6.3 Pinging Remote Devices
The ping utility is used to confirm IP connectivity by pinging other IP hosts. The connectivity is confirmed be receiving a reply from the remote (pinged) hosts.
To ping a host:
1. From the Diagnostics menu, choose Ping.
The Ping menu appears (see
2. From the Ping menu, choose IP Address, and then enter the desired host IP address.
3. From the Ping menu, choose Number of Pings, and then enter the number of pings.
4. From the Ping menu, choose Activate to activate the pinging.
>
Ping
1. Ip Address... (0.0.0.0)
2. Number Of Pings[1 - 16]... (1)
3. Activate
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 6-7. Ping Menu
6.4 Displaying the Active Tests
The MT120xA management software allows you to display tone injection and loopbacks currently in progress.
To display all active tests:
• From the Diagnostics menu, choose Display Active tests.
MT120xA displays a list of active tests, specifying the timeslot being tested
(for tone injection only).
Displaying the Active Tests 6-5
Chapter 6 Diagnostics
6-6 Displaying the Active Tests
Chapter 7
Monitoring and Statistics
Collection
This chapter describes the alarms, sanity checks (configuration errors and warnings), main link and voice module statistics supported by MT120xA.
7.1 Alarms
MT120xA detects fault conditions and initiates alarms and events to alert the user:
• Alarms (major and minor) have two statuses, ON and OFF. Alarm status changes to OFF, when a fault condition that caused it is cleared.
• Events have only ON status.
Alarm Buffer
MT120xA maintains two alarm buffers:
• Temporary buffer, represented as the Display All Alarms screen. All alarms, including active alarms, can be deleted from this display.
• Permanent buffer, represented as the Alarm Status screen. Only inactive alarms can be deleted from the Alarm Status screen.
An alarm simultaneously enters both the Display All Alarms log and the Alarm
Status log, and the ALM LED lights to indicate the condition. In addition,
MT120xA displays the ALARM ON indication in the top right-hand corner of the terminal screen. When the event that caused the alarm is cleared, the alarm status changes to OFF, enabling the alarm to be deleted from the permanent buffer.
Working with the Temporary Alarm Buffer
The temporary alarm buffer is represented as the Display All Alarms screen.
To access the Display All Alarms screen:
1. From the Main menu, choose Monitoring.
The Monitoring menu appears (see
2. From the Monitoring menu, choose Status.
The Status menu appears (see
3. From the Status menu, choose Display.
The Display menu appears (see
Alarms 7-1
Chapter 7 Monitoring and Statistics Collection
>
Monitoring
1. Status>
2. Statistics>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-1. Monitoring Menu
4. From the Display menu, choose Display All Alarms to view the alarms.
MT120xA displays the temporary alarm buffer (see
The display includes the alarm identification code, its severity, its status, and the generation date and time.
To delete alarms from the temporary buffer:
• From the Display menu, choose Display & Clear Alarms to view and delete the current alarms.
MT120xA displays the current alarms and deletes them from the buffer when the user exits the screen.
Status
1. Display>
2. Clear>
3. Display Sanity>
>
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-2. Status Menu
7-2 Alarms
Chapter 7 Monitoring and Statistics Collection
>
Display
1. Display all Alarms
2. Display & Clear Alarms
3. Display Alarm status
Please select item <1 to 3>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-3. Display Menu
(88) AIS RED ALARM MAJOR 10-03-2001 01:50:16
(88) AIS RED ALARM OFF 10-03-2001 01:50:1
(20) INTERNAL ERROR Event 10-03-2001 01:48:15
Press ‘y’ To Continue...
Press ‘n’ To Stop.
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-4. Temporary Alarms Buffer (Display All Alarms Screen)
Working with the Permanent Buffer
The permanent buffer is represented by the Alarm Status screen.
To access the Alarm Status screen:
• From the Display menu (see
), select Display Alarm Status.
MT120xA displays the permanent alarm buffer (see
Alarms 7-3
Chapter 7 Monitoring and Statistics Collection
To delete inactive alarms from the permanent buffer:
1. From the Status menu, select Clear.
The Clear menu appears.
2. Confirm the alarm deletion by choosing Clear All Alarms from the Clear menu.
MT120xA deletes all alarms in the OFF state and events from the permanent buffer.
(81) EXCESSIVE ERROR RATIO MAJOR
(81) EXCESSIVE ERROR RATIO OFF
(20) INTERNAL ERROR Event
Press ‘y’ To Continue...
Press ‘n’ To Stop.
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-5. Permanent Buffer (Alarm Status Screen)
List of MT120xA Alarms
lists the MT120xA alarms according to their identification codes.
Table 7-1. MT120xA Alarms
ID Code Terminal Message
18 DB UPDATE OCCURRED
Description
MT120xA database has been updated
Severity
Event
Event
80
81
Note: The INTERNAL ERROR alarm is used for software debugging. To receive detailed description of each internal alarm, enable ‘Open
Internal Alarms’ from the System menu (Main
menu > Configuration > System > Open
Internal Alarms).
BPV ERROR HAS
OCCURRED
A bipolar violation error has been detected on the E1 port
EXCESSIVE ERROR RATIO
The bit error rate of the port exceeds 1×10
-3
Event
Major
7-4 Alarms
Chapter 7 Monitoring and Statistics Collection
Table 7-1. MT120xA Alarms (Cont.)
ID Code Terminal Message Description Severity
82 ALARM
SIGNAL
INDICATION AIS is being detected at the E1 port
BIPOLAR
VIOLATION
Excessive BPVs at the E1 port
84 T1/E1 FRAME SLIP HAS
OCCURRED
A frame slip occurred at the E1/T1 port
Major
Major
Event
87
88
T1/E1 SIGNAL LOSS
AIS RED ALARM
Loss of input signal at the E1/T1 port
Local loss of frame synchronization at the T1 port caused by AIS condition
Major
Major
Local loss of frame synchronization at the E1 port Major 89
90
LOC SYNC LOSS
(RED ALARM)
REM SYNC LOSS
(YELLOW ALARM)
Remote loss of frame synchronization at the E1 port
MULTIFRAME
ALARM
Local loss of multiframe synchronization at the E1 port
98 REMOTE
ALARM
Remote loss of multiframe synchronization at the
E1 port
Major
Minor
Minor
100
130
131
CRC ERROR OCCURRED
OVERFLOW
TRUNK IS DOWN
CRC-4 error in the E1 port receive signal
The required bandwidth exceeds the available bandwidth on the serial main link
A fault exists on the line. This alarm applies only to the serial main link port with the DTE clock mode configured and control signals enabled.
Minor
Major
Major
195 BUNDLE IS OOS Bundle is out of service due to the network connectivity problems
Major
7.2 Sanity Checks
Configuration errors and mismatches are rendered by the MT120xA management software as sanity checks. Their main purpose is to maintain the database validity.
MT120xA supports two types of the sanity check messages:
• Error – major configuration error, which prevents the MT120xA database from updating and saving changes.
• Warning – minor configuration error, which allows the user to update the database and save the changes.
Sanity Checks 7-5
Chapter 7 Monitoring and Statistics Collection
Displaying the Sanity Errors and Warnings
Every time you update the MT120xA database, the management software analyses the changes. If a major error is detected, MT120xA aborts the database update and displays the following message:
Data base wasn’t changed. Sanity Error - Check alarm.
If a minor error is detected, MT120xA updates the database and displays the following message:
Sanity Warning - Check alarm.
To display the sanity errors and warnings:
1. From the Status menu (see
The Display Sanity menu appears (see
>
Display Sanity
1. Error
2. Warning
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-6. Display Sanity Menu
2. From the Display Sanity menu, choose Error to display the sanity errors or choose Warning to display the sanity warnings.
The sanity error or warning list is displayed.
Chapter 7 Monitoring and Statistics Collection
List of Sanity Errors and Warnings
lists all sanity errors and warnings generated by MT120xA, in
alphabetical order.
Table 7-2. Sanity Errors and Warnings
BUNDLE DESTINED TO A
PHONE HAS DEST TS OUT
OF RANGE
BUNDLE IS NOT
CONNECTED
CCS TS NOT RELATED TO
THE SAME BUNDLE
Error The destination type is a phone and the specified destination timeslot exceeds 4. Specify a timeslot between 1 and 4, since the FXS supports 4 phones.
Warning A timeslot is assigned to a bundle which is not connected
CCS TS NOT RELATED TO
THE SAME PORT
CODER PROBLEM
Error
Error
Error
At least two timeslots of the E1/T1 port with the CCS signaling are assigned to different bundles. To avoid it, assign all timeslots of the same E1/T1 port with the CCS signaling to the same bundle.
At least two timeslots of the E1/T1 port with the CCS signaling are assigned to different destination slots. To avoid it, assign all timeslots of the same E1/T1 port with the CCS signaling to the same destination slot.
Conflict in the DSP capacity and timeslot configuration. Since each DSP handles six timeslots, every six consecutive timeslots must be configured to use the same voice compression method.
Connectivity values of all bundles which belong to the same group (have the same source IP) must be the same.
CONNECTIVITY VALUES
MUST BE THE SAME FOR ALL
GROUP BUNDLES
DEST TS IS OUT OF RANGE
(DEST PHONE)
DISCONNECT BUNDLE
BEFORE CHANGING CODER
RATE
DOUBLE ROUTE
EMPTY ADMINISTRATOR
LIST
EXTERNAL NOT
CONNECTED
Error
Error
Error
The destination type is a phone and the specified destination timeslot exceeds 4. Specify a timeslot between 1 and 4, since the FXS supports 4 phones.
Voice compression type was changed for a connected bundle.
A mismatch between a voice compression type of an active local bundle and that of the destination bundle may cause problems at a DSP. To avoid this, do the following:
1. Disconnect a bundle of the local MT120xA.
2. Disconnect destination bundle of the remote MT120xA.
3. Change the voice compression method for both bundles.
4. Reconnect the bundles.
Error More than one timeslot is connected to the same destination timeslot
Error The last administrator account is deleted from the user database.
Warning A timeslot is assigned to an E1/T1 port which is not connected
Sanity Checks 7-7
Chapter 7 Monitoring and Statistics Collection
Table 7-2. Sanity Errors and Warnings (Cont.)
ILLEGAL DESTINATION IP
ADDRESS
ILLEGAL RINGER PROFILE
PERIOD #2
Error
Error
TS INCOMPATIBLE WITH E1
TYPE
Error
TOO MANY CONFIGURED
TS
TS 16 SHOULD BE
DISCONNECTED IN CAS
MODE
Error
Error
Destination IP address for a bundle is not defined
One of the parameters in the second ringer period is set to zero. Either both parameters must be set to zero, or both parameters must be set to non-zero values.
The first parameter represents the ring period of the second ring; the second parameter represents the silence period that follows the second ring.
Timeslot 16 is configured to HDLC when E1 is set to the
G.732S framing mode. Timeslot 16 configuration must be changed to N.C.
Number of timeslots assigned to carry voice exceeds the number of timeslots supported by the unit
Timeslot 16 is configured to Voice when operating MT120xA with CAS signaling. Timeslot 16 configuration must be changed to N.C.
7.3 Collecting Statistics
This section explains how to display performance data collected on the MT120xA main link and voice ports. You can access performance data via the Statistics menu
(see
Statistics
1. Bundles statistics>
2. Voice statistics>
3. Voice Rx Signaling statistics
4. Voice Tx Signaling statistics
5. E1/T1 Hdlc statistics>
6. Serial Port statistics>
>
7. Ethernet statistics>
Please select item <1 to 7>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-7. Statistics Menu
7-8 Collecting
Chapter 7 Monitoring and Statistics Collection
To display the Statistics menu:
• From the Monitoring menu (see
The Statistics menu appears.
Displaying Bundle Statistics
The management software enables you to evaluate the performance of each of the
describes the bundle statistics
values.
The bundles may have one of the following statuses:
• Connect – The bundle is connected
• Disconnected – The bundle is disconnected
• Echo Wait – There is physical connection, but the remote bundle is not active.
• IP OOS – There is no physical connection between the bundles. The reason for this may be an illegal IP address of the destination E1/T1 group.
To display the bundle statistics:
1. From the Statistics menu, select Bundles Statistics.
The Bundles Statistics menu appears (see
2. From the Bundles Statistics menu, choose Bundle Number, type the number of the bundle whose statistics you want to view, and then press <Enter>.
Bundles statistics
1. Bundle Number[1 - 12]... (1)
2. Mode>
>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-8. Bundles Statistics Menu
3. From the Bundles Statistics menu, choose Mode.
The Mode menu appears (see
Collecting Statistics 7-9
Chapter 7 Monitoring and Statistics Collection
>
Mode
1. Clear
2. Display
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-9. Mode Menu
4. From the Mode menu, choose Display.
The Bundle Statistics screen is displayed (see
describes the bundle statistics values.
5. Press <Y> to refresh the display.
6. Press <ESC> to exit the Bundle Statistics screen.
Statistics on Bundle: 1, State: DISCONNECT
Rx statistics
Total Frames :[ 0 ] Total Bytes :[ 0 ]
60 sec Frames :[ 0 ] 60 sec Bytes :[ 0 ]
Tx statistics Type
Total Frames :[ 0 ] Total Bytes :[ 0 ]
60 sec Frames :[ 0 ] 60 sec Bytes :[ 0 ]
Tx on Timeout :[ 0 ] Tx Max Size :[ 0 ]
60 sec Timout :[ 0 ] 60 sec Max Size :[ 0 ]
Data Type
Total - Rx Sg :[ 0 ] Rx Voice :[ 0 ] Rx Hdlc :[ 0 ]
60 sec- Rx Sg :[ 0 ] Rx Voice :[ 0 ] Rx Hdlc :[ 0 ]
Total - Tx Sg :[ 0 ] Tx Voice :[ 0 ] Tx Hdlc :[ 0 ]
60 sec- Tx Sg :[ 0 ] Tx Voice :[ 0 ] Tx Hdlc :[ 0 ]
Silence percent on bundle - Rx :[ 10 ] Tx :[ 10 ]
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-10. Bundle Statistics
7-10 Collecting
Chapter 7 Monitoring and Statistics Collection
Table 7-3. Bundle Statistics Values for Voice Port
Total - Rx Sg
Total - Rx Voice
Total - Rx Hdlc
60 sec - Rx Sg
60 sec - Rx Voice
60 sec - Rx Hdlc
Total - Tx Sg
Total - Tx Voice
Total - Tx Hdlc
60 sec - Tx Sg
60 sec - Tx Voice
60 sec - Tx Hdlc
Silence percent on bundle Rx
Silence percent on bundle Tx
Field Description
Rx Total Frames
Rx Total Bytes
Rx 60 sec Frames
Rx 60 sec Bytes
Tx Total Frames
Tx Total Bytes
Tx 60 sec Frames
Tx 60 sec Bytes
Tx on Timeout
Tx Max Size
60 sec Timeout
60 sec Max Size
Total number of packets received
Total number of data octets of all packets received
Number of packets received during the last 60 seconds
Number of data octets received during the last 60 seconds
Total number of packets transmitted
Total number of data octets of all packets transmitted
Number of packets transmitted during the last 60 seconds
Number of data octets transmitted during the last 60 seconds
Number of packets transmitted as a result of reaching the maximum packetizing interval
Number of packets transmitted as a result of reaching the maximum frame size
Number of packets transmitted as a result of reaching the maximum packetizing interval during the last 60 seconds
Number of packets transmitted as a result of reaching the maximum frame size during the last 60 seconds
Total number of received signaling bits
Total number of received voice bits
Total number of received HDLC bits
Number of signaling packets received during last 60 seconds
Number of voice packets received during last 60 seconds
Number of HDLC packets received during last 60 seconds
Total number of transmitted signaling bits
Total number of transmitted voice bits
Total number of transmitted HDLC bits
Number of signaling packets transmitted during last 60 seconds
Number of voice packets transmitted during last 60 seconds
Number of HDLC packets transmitted during last 60 seconds
Average percentage of silence on all the received timeslots connected to the bundle
Average percentage of silence on all the transmitted timeslots connected to the bundle
To clear the bundle statistics registers:
1. From the Bundles Statistics menu (see
The Mode menu appears (see
2. From the Mode menu, choose Clear.
Collecting Statistics 7-11
Chapter 7 Monitoring and Statistics Collection
Displaying Timeslot Voice Statistics
The MT120xA software enables you to evaluate performance of a separate
timeslot and the DSP used by it (see
voice statistics values.
To display the timeslot voice statistics:
1. From the Statistics menu (see
The Voice Statistics menu appears (see
>
Voice statistics
1. Time Slot[1 - 31]... (1)
2. Mode>
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-11. Voice Statistics Menu
2. From the Voice Statistics menu, choose Time Slot, type the number of the timeslot whose statistics you want to view, and then press <Enter>.
3. From the Voice Statistics menu, choose Mode.
The Mode menu appears (see
4. From the Mode menu, choose Display.
The Timeslot Voice Statistics screen is displayed (see
describes the timeslot voice statistics values.
5. Press <Y> to refresh the display.
6. Press <ESC> to exit the Bundle Statistics screen.
7-12 Collecting
Chapter 7 Monitoring and Statistics Collection
Voice Statistics Time Slot: 1
Dsp Mode :[ IDLE]
Total Rx Voice :[ 0 ] Total Tx Voice :[ 0 ]
Total Rx Sid :[ 0 ] Total Tx Sid :[ 0 ]
Total Rx Fax :[ 0 ] Total Tx Fax :[ 0 ]
Total Underun :[ 0 ] Total Overrun :[ 0 ]
Max jitter len :[ 150 ]
Silence percent since last clear: Rx: [ 10 ] Tx: [ 10 ]
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-12. Timeslot Voice Statistics Screen
Table 7-4. Timeslot Voice Statistics Values
Field Description
DSP Mode
Total Rx Voice
Total Tx Voice
Total Rx Sid
Total Tx Sid
Total Rx Fax
Total Tx Fax
Total Underrun
Total Overrun
Max jitter len
Silence percent since last clear: Rx
Silence percent since last clear: Tx:
• IDLE – DSP is idle
• VOICE – DSP is transmitting voice packets
• DATA – DSP is transmitting HDLC packets
• FAX –DSP is relaying fax signal
• VOICEBAND – DSP is transmitting voiceband data (modem)
Total number of voice packets received from the DSP
Total number of voice packets transmitted to the DSP
Total number of silence packets received from the DSP
Total number of silence packets transmitted to the DSP
Total number of fax packets received from the DSP
Total number of fax packets transmitted to the DSP
Total underrun of the jitter buffer (in packets)
Total overrun of the jitter buffer (in packets)
Max length of the jitter buffer (in msec)
Average percentage of silence carried by the received timeslot since buffer was last cleared
Average percentage of silence carried by the transmitted timeslot since buffer was last cleared
Collecting Statistics 7-13
Chapter 7 Monitoring and Statistics Collection
To clear the timeslot voice statistics registers:
1. From the Voice Statistics menu, choose Mode.
2. From the Mode menu, choose Clear.
Displaying the Voice Signaling Statistics (MT1200A, MT1207A, MT120 xAE)
When operating with the CAS signaling (E1 or T1 voice port only), MT120xA transmits signaling information in one of the timeslots. You can display the mapping of the ABCD bits used by each timeslot inside the signaling timeslot (see
• Rx signaling – Signaling transmitted from the E1/T1 trunk or PBX
• Tx signaling – Signaling transmitted towards the E1/T1 trunk or PBX.
To display the signaling statistics:
1. From the Statistics menu, choose Voice Rx Signaling Statistics to display the
Rx signaling statistics, or choose Voice Tx Signaling Statistics to display the Tx signaling statistics.
The Voice Rx Signaling Statistics screen (see
Signaling Statistics screen (see
2. Press <Y> to refresh the display.
3. Press <ESC> to exit the signaling statistics screen.
Voice Rx Signaling Statistics
Ts1 :[ 0000 ] Ts2 :[ 0000 ] Ts3 :[ 0000 ]
Ts4 :[ 0000 ] Ts5 :[ 0000 ] Ts6 :[ 0000 ]
Ts7 :[ 0000 ] Ts8 :[ 0000 ] Ts9 :[ 0000 ]
Ts10 :[ 0000 ] Ts11 :[ 0000 ] Ts12 :[ 0000 ]
Ts13 :[ 0000 ] Ts14 :[ 0000 ] Ts15 :[ 0000 ]
Ts17 :[ 0000 ] Ts18 :[ 0000 ] Ts19 :[ 0000 ]
Ts20 :[ 0000 ] Ts21 :[ 0000 ] Ts22 :[ 0000 ]
Ts23 :[ 0000 ] Ts24 :[ 0000 ] Ts25 :[ 0000 ]
Ts26 :[ 0000 ] Ts27 :[ 0000 ] Ts28 :[ 0000 ]
Ts29 :[ 0000 ] Ts30 :[ 0000 ] Ts31 :[ 0000 ]
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-13. Voice Rx Signaling Statistics
7-14 Collecting
Chapter 7 Monitoring and Statistics Collection
Voice Tx Signaling Statistics
Ts1 :[ 0000 ] Ts2 :[ 0000 ] Ts3 :[ 0000 ]
Ts4 :[ 0000 ] Ts5 :[ 0000 ] Ts6 :[ 0000 ]
Ts7 :[ 0000 ] Ts8 :[ 0000 ] Ts9 :[ 0000 ]
Ts10 :[ 0000 ] Ts11 :[ 0000 ] Ts12 :[ 0000 ]
Ts13 :[ 0000 ] Ts14 :[ 0000 ] Ts15 :[ 0000 ]
Ts17 :[ 0010 ] Ts18 :[ 0010 ] Ts19 :[ 0010 ]
Ts20 :[ 0010 ] Ts21 :[ 0010 ] Ts22 :[ 0010 ]
Ts23 :[ 0010 ] Ts24 :[ 0010 ] Ts25 :[ 0010 ]
Ts26 :[ 0010 ] Ts27 :[ 0010 ] Ts28 :[ 0010 ]
Ts29 :[ 0010 ] Ts30 :[ 0010 ] Ts31 :[ 0010 ]
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-14. Voice Tx Signaling Statistics
Displaying the FXS Signaling Statistics (MT1201A only)
MT1201A records statistics about the FXS analog voice ports.
To display the FXS signaling statistics:
• From the Statistics menu (see
), choose FXS Signaling Statistics.
The FXS Signaling Statistics screen is displayed. Press <Enter> to refresh the display. Press <ESC> to exit the FXS signaling statistics screen.
>
FXS Signaling statistics
Ts# Type Bundle Dest Type Dest Port Dest Ts State
1 N.C 0 PBX 1 0 BOTH_ON_HOOK
2 N.C 0 PBX 1 0 BOTH_ON_HOOK
3 N.C 0 PBX 1 0 BOTH_ON_HOOK
4 N.C 0 PBX 1 0 BOTH_ON_HOOK
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 7-15. FXS Signaling Statistics Screen
The State of the FXS port can be one of the following:
• BOTH_ON_HOOK (both local and remote handsets are on-hook)
Collecting Statistics 7-15
Chapter 7 Monitoring and Statistics Collection
• RINGBACK (ring-back signal is being sent from remote handset)
• ACTIVE_CALL (call is in progress)
• LOCAL_ON_HOOK (local handset is on-hook, remote handset is not on-hook)
• REMOTE_ON_HOOK (remote handset is on-hook, local handset is not onhook)
• RINGING (remote handset is ringing)
Displaying HDLC Statistics
When the timeslots of the E1/T1 voice ports are configured to carry the HDLC data, MT120xA collects HDLC traffic statistics (see
describes the HDLC statistics values.
HDLC statistics are not relevant for MT1201A units.
To display the HDLC statistics:
1. From the Statistics menu, choose E1/T1 Hdlc Statistics.
The E1/T1 HDLC Statistics menu appears.
2. From the HDLC Statistics menu, choose Display.
The HDLC Statistics screen is displayed (see Figure 7-16).
describes the HDLC statistics values.
3. Press <Y> to refresh the display.
4. Press <ESC> to exit the HDLC Statistics screen.
Hdlc Statistics
Rx statistics
Total Frames :[ 0 ] Total Bytes :[ 0 ]
60 sec Frames :[ 0 ] 60 sec Bytes :[ 0 ]
Length Error :[ 0 ] NonOctet Aligned :[ 0 ]
Aborted Frames :[ 0 ] Crc Error :[ 0 ]
Overrun :[ 0 ]
Tx statistics
Total Frames :[ 0 ] Total Bytes :[ 0 ]
60 sec Frames :[ 0 ] 60 sec Bytes :[ 0 ]
Underrun :[ 0 ]
Tx Queue - Max Frames :[ 0] Current Frames :[ 0]
Freed Frames :[ 0]
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-16. HDLC Statistics Screen
7-16 Collecting
Chapter 7 Monitoring and Statistics Collection
Table 7-5. HDLC Statistics Values
Field Description
Rx Total Frames
Rx Total Bytes
Rx 60 sec Frames
Rx 60 sec Bytes
Length Error
NonOctet Aligned
Aborted Frames
Total number of HDLC packets received
Total number of data octets of all packets received
Number of HDLC packets received during last 60 seconds
Number of data octets received during last 60 seconds
Number received frames with length violations
Number of received frames which contain a number of bits not divisible by eight
Number of aborted sequences. The counter is incremented by one when at least seven consecutive ones are received during frame reception
Number of received frames with CRC errors Crc Error
Rx Overrun
Tx Total Frames
Tx Total Bytes
Tx 60 sec Frames
Tx 60 sec Bytes
Tx Underrun
Number of received HDLC packets discarded due to lack of buffer resources
Total number of HDLC packets transmitted
Total number of data octets of all packets transmitted
Number of HDLC packets transmitted during last 60 seconds
Number of data octets transmitted during last 60 seconds
Number of transmitted HDLC packets discarded due to lack of buffer resources
Tx Queue - Max Frames Maximum number of the transmitted HDLC packets ever accumulated in the
FIFO buffer
Tx Queue - Current
Frames
Current number of the transmitted HDLC packets in the FIFO buffer
Freed Frames Number of frames discarded from the FIFO buffer when the number of stored frames exceeded buffer capacity
To clear the HDLC statistics registers:
• From the E1/T1 HDLC Statistics menu, choose Clear.
Displaying the Serial Port Statistics
MT120xA evaluates performance of the Serial port (see
describes the Serial port statistics values.
To display the Serial port statistics:
1. From the Statistics menu, choose Serial Port Statistics.
The Serial Port Statistics menu appears (see
Collecting Statistics 7-17
Chapter 7 Monitoring and Statistics Collection
>
Serial Port statistics
1. Clear
2. Display
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-17. Serial Port Statistics Menu
2. From the Serial Port Statistics menu, choose Display.
The Serial Port Statistics screen is displayed (see
describes the Serial port statistics values.
Serial Port Statistics
Rx statistics
Total Frames :[ 0 ] Total Bytes :[ 0 ]
60 sec Frames :[ 0 ] 60 sec Bytes :[ 0 ]
Length Error :[ 0 ] NonOctet Aligned :[ 0 ]
Aborted Frames :[ 0 ] Crc Error :[ 0 ]
Overrun :[ 0 ] Freed Rx Frames :[ 0 ]
Tx statistics
Total Frames :[ 0 ] Total Bytes :[ 0 ]
60 sec Frames :[ 0 ] 60 sec Bytes :[ 0 ]
Underrun :[ 0 ] Freed Tx Frames :[ 0 ]
Tx Voice Q - Current Frames :[ 0] Max Frames :[ 0]
Tx Data Q - Current Frames :[ 0] Max Frames :[ 0]
Tx Mng Q - Current Frames :[ 0] Max Frames :[ 0]
BandWidth To Line - Average:[ 0] Max:[ 0] (bit/Sec)
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-18. Serial Port Statistics Screen
7-18 Collecting
Chapter 7 Monitoring and Statistics Collection
Table 7-6. Serial Port Statistics Values
Field Description
Rx Total Frames
Rx Total Bytes
Rx 60 sec Frames
Rx 60 sec Bytes
Rx Length Error
Rx NonOctet Aligned
Rx Aborted Frames
Total number of HDLC packets received
Total number of data octets of all packets received
Number of HDLC packets received during last 60 seconds
Number of data octets received during last 60 seconds
Number received frames with length violations
Number of received frames which contain a number of bits not divisible by eight
Number of aborted sequences. The counter is incremented by one when at least seven consecutive ones are received during frame reception
Number of received frames with CRC errors Rx Crc Error
Rx Overrun
Freed RX Frames
Tx Total Frames
Tx Total Bytes
Tx 60 sec Frames
Number of received HDLC packets discarded due to lack of buffer resources
Number of frames discarded from the FIFO buffer when the number of stored frames exceeded buffer capacity
Total number of HDLC packets transmitted
Total number of data octets of all packets transmitted
Number of HDLC packets transmitted during last 60 seconds
Tx 60 sec Bytes
Tx Underrun
Freed Tx Frames
Number of data octets transmitted during last 60 seconds
Number of transmitted HDLC packets discarded due to lack of buffer resources
Number of frames discarded from the FIFO buffer when the number of stored frames exceeded buffer capacity
Current number of the transmitted HDLC voice packets in the FIFO buffer Tx Voice Q - Current
Frames
Tx Voice Q - Max
Frames
Tx Data Q - Current
Frames
Tx Data Q - Max
Frames
Maximum number of the transmitted HDLC voice packets ever accumulated in the FIFO buffer
Current number of the transmitted HDLC data packets in the FIFO buffer
Tx Mng Q - Current
Frames
Maximum number of the transmitted HDLC data packets ever accumulated in the FIFO buffer
Current number of the transmitted HDLC management packets in the FIFO buffer
Tx Mng Q - Max Frames Maximum number of the transmitted HDLC management packets ever accumulated in the FIFO buffer
Collecting Statistics 7-19
Chapter 7 Monitoring and Statistics Collection
Displaying the Ethernet Statistics
MT120xA evaluates performance of the 10/100BaseT Ethernet port (see
describes the Ethernet statistics values.
To display the Ethernet statistics:
1. From the Statistics menu, choose Ethernet Statistics.
The Ethernet Statistics menu appears (see
>
Ethernet statistics
1. Clear
2. Display
Please select item <1 to 2>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 7-19. Ethernet Statistics Menu
2. From the Ethernet Statistics menu, select Display.
The Ethernet Statistics screen is displayed (see
describes the Ethernet statistics values.
3. Press <Y> to refresh the display.
4. Press <ESC> to exit the Ethernet Statistics screen.
7-20 Collecting
Chapter 7 Monitoring and Statistics Collection
Switch Statistics
Network Port User Port
Rx Total Frames :[ 0 ] [ 0 ]
Rx 60sec Frames :[ 0 ] [ 0 ]
Tx Total Frames :[ 0 ] [ 0 ]
Tx 60sec Frames :[ 0 ] [ 0 ]
PHY Err Count :[ 0 ] [ 0 ]
PHY 60sec Err Count:[ 0 ] [ 0 ]
Freed Rx Frames (Network & User): [ 0 ]
Press 'Y' for refresh , ESC - for exit.
ESC-prev.menu; !-main menu; &-exit
Figure 7-20. Ethernet Statistics Screen
Table 7-7. Ethernet Statistics Values
Field Description
Network Port: Rx Total
Frames
Network Port: Rx 60 sec Frames
Network Port: Tx Total
Frames
Network Port: Tx 60 sec
Frames
Network Port: PHY Err
Count
Network Port: PHY 60 sec Err Count
User Port: Rx Total
Frames
User Port: Rx 60 sec
Frames
User Port: Tx Total
Frames
User Port: Tx 60 sec
Frames
Total number of packets received on Network port
Number of packets received during last 60 seconds on Network port
Total number of packets transmitted on Network port
Number of packets transmitted during last 60 seconds on Network port
Total number of errors on Network port
Number of errors during the last 60 seconds on Network port
Total number of packets received on User port
Number of packets received during last 60 seconds on User port
Total number of packets transmitted on User port
Number of packets transmitted during last 60 seconds on User port
Collecting Statistics 7-21
Chapter 7 Monitoring and Statistics Collection
Table 7-7. Ethernet Statistics Values (Cont.)
Field Description
User Port: PHY Err
Count
User Port: PHY 60 sec
Err Count
Freed Rx Frames
(Network & User
Total number of errors on User port
Number of errors during the last 60 seconds on User port
Total number of frames freed due to errors
To clear the Ethernet statistics registers:
• From the Ethernet Statistics menu, choose Clear.
7-22 Collecting
Appendix A
Interface Connector
Specifications
A.1 Voice Ports
T1/E1 Interface Connector (MT1200A, MT1207A, MT120 xAE)
The balanced T1/E1 voice port interface terminates in a RJ-45 connector.
illustrates the pin location in the RJ-45 connector.
lists the
T1/E1 connector pin assignment.
1 8
Figure A-1. RJ-45 Connector Pin Location
Table A-1. T1/E1 RJ-45 Connector Pinout
Pin
1, 2
4, 5
Function
Receive (input)
Transmit (output)
FXS Interface Connectors (MT1201A only)
The FXS interfaces terminate in RJ-11 connectors.
location in the RJ-11 connector.
lists the FXS connector pin assignment.
1 6
Figure A-2. RJ-11 Connector Pin Location
Table A-2. FXS Connector Pinout
Pin Function
3 Ring
4 Tip
Voice Ports A-1
Chapter A Interface Connector Specifications
A.2 Ethernet Interface Connectors
The 10/100BaseT user and network port interfaces also terminate in RJ-45 connectors (previously illustrated in
connector pin assignment.
Table A-3. Ethernet Connector Pinout
3
6
1
2
TD (+)
TD (-)
RD (+)
RD (-)
Transmit Data (positive)
Transmit Data (negative)
Receive Data (positive)
Receive Data (negative)
Note
Ethernet main link port supports connection via straight and cross cables.
A-2 Ethernet Interface Connectors
Chapter A Interface Connector Specifications
A.3 Serial Port
Serial Port Connector
The MT120xA Serial port terminates in an RS-530/DCE interface with a female
DB-25 connector.
lists the pin assignment of the Serial port DB-25
connector.
Table A-4. DB-25 Serial Port Connector Pin Assignment
Pin Number Function Direction
18 – –
21 – –
25 – –
Serial Port A-3
Chapter A Interface Connector Specifications
Additional interfaces are supported via interface adapter cables that convert the
MT120xA Serial port’s RS-530/DCE interface to the target Serial interface.
lists the supported Serial interfaces and the name of the associated Serial
interface cable. The pin assignment of the Serial interface adapter cables are provided in the sections that follow.
Table A-5. Serial Interfaces supported by MT120xA
Serial Interface Adaptor Cable Interface Adapter
Cable Pin Assignment
RS-530/DTE MT1205
–
–
RS-530A/DTE MT1205
V.35/DCE MT1203
X.21/DCE
CBL-VM110/X21/DCE
X.21/DTE
CBL-VM110/X21/DTE
Chapter A Interface Connector Specifications
RS-530/DTE Interface Adapter Cable
The MT1205 interface adapter cable converts the MT120xA Serial port into an
RS-530/DTE Serial interface. The interface adapter cable terminates in a female
D-25 connector.
lists the pin assignment at each end of the interface
cable.
Table A-6. MT1205 Interface Cable Pin Assignment
Pin on DB-25 Connector
(Vmux-110 Serial Port Side)
Pin on DB-25 Connector
(User Equipment Side)
1 1
7 7
22 23
6 20
23 22
20 6
10 10
8 8
19 13
4 5
13 19
5 4
24 9
11 17
12 12
15 15
9 11
17 24
14 16
2 3
16 14
3 2
Serial Port A-5
Chapter A Interface Connector Specifications
V.35/DCE Interface Adapter Cable
The MT1203 interface adapter cable converts the MT120xA Serial port into a
V.35/DCE Serial interface. The interface cable terminates in a male V.35 connector.
lists the pin assignment at each end of the interface cable.
Table A-7. MT1203 Interface Cable Pin Assignment
Pin on DB-25 Connector Pin on V.35 Connector
1 A
3 R
16 T
2 P
14 S
24 U
11 W
17 V
9 X
15 Y
12 AA(a)
5 D
4 C
20 H
7 B
8 F
6 E
Chapter A Interface Connector Specifications
V.35/DTE Interface Adapter Cable
The MT1204 interface adapter cable converts the MT120xA Serial port into a
V.35/DTE Serial interface. The interface cable terminates in a male V.35 connector.
lists the pin assignment at each end of the interface cable.
Table A-8. MT1204 Interface Cable Pin Assignment
Pin on DB-25 Connector Pin on V.35 Connector
1 A
3 P
16 S
2 R
14 T
24 V
11 X
17 U
9 W
15 Y
12 AA(a)
5 C
4 D
20 E
7 B
8 F
6 H
Serial Port A-7
Chapter A Interface Connector Specifications
X.21/DCE Interface Adapter Cable
The CBL-VM110/X21/DCE interface adapter cable converts the MT120xA Serial port into an X.21/DCE Serial interface. The interface cable terminates in a female
D-15 connector.
lists the pin assignment at each end of the interface
cable.
Table A-9. X.21/DCE Interface Cable Pin Assignment
Pin on DB-25 Connector Pin on D-15 Connector Comments
1 1
7 8
4 3
19 10
Twisted
8 5
10 12
Twisted
15 6
12 13
Twisted
2 2
Twisted
14 9
3 4
16 11
Twisted
24 7
11 14
Twisted
Chapter A Interface Connector Specifications
X.21/DTE Interface Adapter Cable
The CBL-VM110/X21/DTE interface adapter cable converts the MT120xA Serial port into an X.21/DTE Serial interface. The interface cable terminates in a male
D-15 connector.
lists the pin assignment at each end of the interface
cable.
Table A-10. X.21/DTE Interface Cable Pin Assignment
Pin on DB-25 Connector Pin on D-15 Connector Comments
1 1
7 8
8 3
10 10
Twisted
4 5
19 12
Twisted
24 6
11 13
Twisted
3 2
Twisted
16 9
2 4
14 11
Twisted
A.4 CONTROL Connector
The control terminal interface terminates in a V.24/RS-232 8-pin RJ-45 connector.
Connection to an ASCII terminal is made via CBL-RJ45/D9/F/STR cable.
lists the cable pin assignment.
Table A-11. CBL-RJ45/D9/F/STR Cable Pin Assignment
RJ-45 DB-9
Pin 4 GND
Pin 5 RX (out)
Pin 6 TX (in)
Pin 7 CTS
Pin 8 RTS
Pin 5 GND
Pin 2 RX
Pin 3 TX
Pin 8 CTS
Pin 7 RTS
CONTROL Connector A-9
Chapter A Interface Connector Specifications
Appendix B
Boot Manager and Software
Downloading
B.1 Introduction
This chapter describes the MT120xA boot software and provides instructions for software downloading via XMODEM or TFTP applications.
The MT120xA software is stored in the flash memory in two sections: boot and file system. The boot sector holds a boot program that calls up the rest of the program from the file system.
The file system can hold two compressed copies of the MT120xA application software. One copy is referred to as active partition (usually partition 1), the other
– as backup partition (usually partition 0). The active partition is decompressed and loaded into the MT120xA RAM upon power-up. The backup file is used whenever the active file is missing or corrupted.
B.2 Booting MT120xA
MT120xA boots up automatically. After power-up, no user intervention is required, except when the user wants to access the file system to modify or update the MT120xA application software.
Boot Sequence
The following is a description of the boot sequence. If the system is working normally, the entire process is completed within two minutes.
1. The boot program searches for the active partition in the file system. If the file exists, the program continues.
If the file does not exist, the boot program searches for the backup file. If the backup is found, it is used instead of the active partition, and the boot process continues.
If there is no backup file, you must download a file via the XMODEM protocol.
The received file is saved as the active file in the file system.
2. Active and backup partitions are compressed and automatically decompressed into the RAM before execution begins.
3. After decompression, the MT120xA software starts to execute and the user can begin working.
Booting MT120xA B-1
Chapter B Boot Manager and Software Downloading
Accessing the File System
The file system menu is an option that allows the user to perform basic file transfer operations. These operations are all optional.
When working with the File System menu, configure the ASCII terminal rate to
115.2 kbps.
To access the File System menu:
• Press <Enter> several times immediately after powering MT120xA up.
The File System menu is displayed (see
RAD VMUX_110 Boot Version 1.40 (Jun 16 2002)
RAD Boot Manager Version 4.30 (Jun 16 2002)
0 – Exit Boot-Manager
1 – Show partitions information
2 – Set the active partition
3 – Erase a partition
4 – Download an application by XMODEM
5 – Select an application to run temporarily
6 – Erase all partitions
7 – Show basic hardware information
8 - System configuration
9 - Download an application by TFTP
Select:
Figure B-1. File System Menu
From the File System menu, you can:
• Show the partition information.
• Set the active partition.
• Erase a partition.
• Download an application via XMODEM application (see the
• Select a partition for a temporary (one-time) use.
• Erase all partitions.
• Display the basic hardware information (RAM, ROM size etc)
• Assign IP values to MT120xA for the client TFTP application (see the
Downloading Application Files using the TFTP
• Download application software via client TFTP application (see the
Downloading Application Files using the TFTP
Chapter B Boot Manager and Software Downloading
Notes
• Partition information displayed via the File System menu, does not include the
application software of the voice interface. Use the ‘Show Partition Information’ menu (Main Menu > Configuration > System > Show Partition
Information) to display complete information on the MT120xA application software.
• You can also exchange the active and backup partitions via the ‘Set the Active
Application’ menu (Main Menu > Configuration > System > Set the Active
Partition).
B.3 Downloading the Application and Configuration
Software
New application software releases are distributed as *.img files, which are downloaded to MT120xA using the XMODEM protocol or client TFTP application from the File System menu of the boot software. Alternatively, you can download a new software release via TFTP protocol, when the MT120xA management software is already running.
The TFTP protocol can also be used for uploading configuration files which contain the MT120xA database to the management station. Administrators can use this capability to distribute verified configuration files to all other units which use the similar configuration.
Downloading Application Files via XMODEM
Downloading application files using the XMODEM protocol is performed from the
File System menu of the boot software.
To download application file via XMODEM:
1. Configure your ASCII terminal or terminal emulation utility running on your PC to the 115.2 kbps data rate.
2. Access the File System menu (see the
The File System menu appears (see
3. From the File System menu, select Download an application by XMODEM.
MT120xA displays the following message:
Select partition to download
4. Select the backup partition by typing its number, 1.
MT120xA requires confirmation of the partition deletion:
The partition is full. Do you want to erase it (y/n)
5. Type Y.
MT120xA responds with the following string:
Please start the XMODEM download.
Downloading the Application and Configuration Software B-3
Chapter B Boot Manager and Software Downloading
6. Send the *.img file to MT120xA using the XMODEM utility of you terminal application.
Once the downloading is completed, MT120xA saves the new release as an active partition, the former active partition turns into backup, and the boot sequence continues normally.
If a failure occurs during the download, the partially downloaded software is erased. In this case, only active software is left in the Flash memory.
Downloading Application Files using the TFTP Server
Downloading application files using the TFTP server application is performed from the File System menu of the boot software.
1. Access the File System menu (see the
The File System menu appears (see
2. From the File System menu, select System configuration.
3. Enter IP address of MT120xA, and press <Enter>.
4. Enter IP mask of MT120xA, and press <Enter>.
5. Enter default gateway of MT120xA, and press <Enter>.
6. Reset MT120xA.
7. Access the File System menu.
8. From the File System menu, select Download an application by TFTP.
9. Enter the application file name (vmux110.img), and press <Enter>.
10. Enter IP address of the TFTP server, and press <Enter>.
MT120xA starts downloading application software.
MT120xA automatically erases the backup partition (it takes about
25 seconds). Once the downloading is completed, MT120xA saves the new release as an active partition, the former active partition turns into backup.
11. Restart the unit.
B-4 Downloading the Application and Configuration Software
Chapter B Boot Manager and Software Downloading
Downloading Application Files using the TFTP Client
The application software is downloaded when MT120xA has completed the boot-up procedure and the management software is running.
To download application file via TFTP:
1. Start a TFTP client application.
2. Configure the communication parameters as follows:
Connection timeout – more than 20 seconds to prevent an automatic disconnection during the backup partition deletion (about 15 seconds).
Block size – 512 bytes.
UDP port – 69.
3. Select a local *.img file to download.
4. Set remote file name to vmux110.img.
5. Enter the MT120xA IP address.
6. Start downloading.
MT120xA automatically erases the backup partition (it takes about
15 seconds). Once the downloading is completed, MT120xA saves the new release as an active partition, the former active partition turns into backup.
7. Restart the unit.
Uploading/Downloading Configuration Files using the TFTP Client
Note
You can upload a MT120xA configuration file (cnfg110.dat) to the management station for further distribution to all other units which use the similar configuration.
To upload application file via TFTP:
1. Start a TFTP client application.
2. Set remote file name to cnfg110.dat.
3. Enter the MT120xA IP address.
4. Start uploading.
When the uploading is completed, you can download the cnfg110.dat file to other MT120xA units. After the downloading, make sure to update the new database software by typing @.
The system and the main link values do not change when you download the new configuration and update the database.
Downloading the Application and Configuration Software B-5
Chapter B Boot Manager and Software Downloading
B-6 Downloading the Application and Configuration Software
Appendix C
Configuration Menus
This appendix lists all menus of the MT120xA management software.
Main Menu
Sheet 1
1. Inventory 2. Configuration 3. Monitoring 4. Diagnostics
Go To
Sheet 5
1. System
1. Management
1. Host IP
1. Set Host IP address
2. Set Subnet Mask
3. Set Default Gateway
4. Trap
5. Read
6. Write
2. Manager List
1. Change Cell
3. Host Mux Name
4. User Administration
2. Switch Lan Configuration 3. Voice Configuration
Go To
Sheet 2
3. FXS Configuration
Go To
Sheet 3
4. Serial Port Configuration
1. Interface Type
2. Connect
3. Speed
4. Clock Mode
5. Clock Invert
6. Control Signals
7. Fragmentation
Go To
Sheet 4
5. Signaling Configuration
1. Signaling Profile Configuration
1. Profile Number To Configure
2. Signaling Table Configuration
2. SS7 Keep-Alive Suppression rate
6. Telnet
1. Disable
2. Enable
3. Enable Managers Only
7. Main Link
1. Serial Port
2. Lan
2. Control Port
1. Set Baud Rate
2. Timeout
3. Date & Time Update
1. Set Time
2. Set Date
4. Factory Default
5. Show Partition information
6. Set the active application
7. Reset Unit
8. Open Internal Alarms
1. Network Port Configuration
1. Set Auto Negotiation
2. Set Capability
1. 10baseT Half Duplex
2. 10baseT Full Duplex
3. 100baseT Half Duplex
4. 100baseT Full Duplex
2. User Port Configuration
1. Set Auto Negotiation
2. Set Capability
1. 10baseT Half Duplex
2. 10baseT Full Duplex
3. 100baseT Half Duplex
4. 100baseT Full Duplex
Figure C-1. MT120xA Menu Tree, Inventory and Configuration Menus
C-1
Chapter C Configuration Menus
Sheet 2
From
Sheet 1
3. Voice Configuration
1. Bundles Parameters
1. Display Bundles
2. Bundle Configuration
1. Add Bundle
2. Delete Bundle
3. Edit Bundle
1. Enter Bundle Number
2. Connect
3. Function
1. TDMoIP
2. AAL2oMPLS
4. Max Bytes In Multiplexed Frame
5. Destination IP
6. Destination Bundle
7. Packetizing Interval
8. Connectivity Parameters
1. Connectivity-packet rate
2. Connectivity timeout cycles
9. TOS Parameters
1. Precedence
2. Delay
3. Throughput
4. Reliability
10. Voice Parameters
1. Coder/Rate
2. Volume
3. Fax/Modem
4. MF Parameter
5. Custom Tone Detection
6. Echo Canceller
9. Coding
11. VLAN Parameters
1. Vlan Exist
2. Vlan Id
3. Vlan Priority
12. Bundle Name
2. E1 Parameters
1. Connect
2. Frame
3. Interface Type
4. Restoration Time
5. Clock Source
6. Idle Code
7. Profile
2. T1 Parameters
1. Connect
2. Clock Mode
3. Frame
4. Interface Type
5. Line Code
6. Line Length
6. Rx Sensitivity
7. Tx Gain Level
8. Restoration Time
9. Idle Code
10. Signaling
11. Profile
3. Distribution of Framer Time Slots
1. Display Time Slots Configuration
2. Configure Time Slots
1. Update from Time Slot
2. To TimeSlot
3. Type
4. Bundle
5. Destination Port
6. Destination Time Slot ID
7. Update Time Slot
Figure C-2. Voice Configuration Menus for E1 and T1 Voice Ports
C-2
Chapter C Configuration Menus
Sheet 3
From
Sheet 1
3. FXS Configuration
1. Bundles Parameters
1. Display Bundles
2. Bundle Configuration
1. Add Bundle
2. Timeouts
2. Delete Bundle
3. Edit Bundle
1. Enter Bundle Number
3. Ringer Profile
1. Period #1: Ring
2. Period #1: Silence
3. Period #2: Ring
4. Period #2: Silence
2. Connect
3. Function
1. TDMoIP
2. AAL2oMPLS
4. Max Bytes In Multiplexed Frame
5. Destination IP
5. Destination Type
1. Ring Timeout
2. On hook duration in Flash
4. Ports Distribution
6. Destination Bundle
7. Packetizing Interval
8. Connectivity Parameters
1. Connectivity-packet rate
2. Connectivity timeout cycles
9. TOS Parameters
5. Port Configuration
1. Port Number
2. Gains
1. TX gain
2. RX gain
3. FXS Signaling Parameters
1. Display Time Slots Configuration
2. Configure Time Slots
1. Update from Time Slot
2. To TimeSlot
3. Type
4. Bundle
5. Destination Port ID
6. Destination Time Slot ID
7. Update Time Slot
1. Precedence
2. Delay
3. Throughput
4. Reliability
10. Voice Parameters
1. Coder/Rate
2. Fax/Modem
3. MF Relay
4. VAD
5. Echo Canceller
11. VLAN Parameters
1. Vlan Exist
2. Vlan Id
3. Vlan Priority
12. Bundle Name
Figure C-3. FXS Configuration Menus for FXS Voice Ports
C-3
Chapter C Configuration Menus
From
Sheet 1
Sheet 4
4. User Administration
1. Add New User
1. Enter UserName
2. Enter Access Level
1. Monitor
2. Technician
3. Operator
4. Administrator
3. Enter Password
4. Confirm Password and save
2. Delete User
1. Enter UserName (to delete)
2. Confirm and delete
3. Change User details
1. Enter UserName (to change)
2. Change password
3. Confirm and save password
4. Change access level
1. Monitor
2. Technician
3. Operator
4. Administrator
5. Confirm and save access level
4. Show all users
Figure C-4. User Administration Menus
C-4
Chapter C Configuration Menus
Sheet 5
From
Sheet 1
3. Monitoring
1. Status
1. Display
1. Display all Alarms
2. Display & Clear Alarms
3. Display Alarm status
2. Clear
1. Clear all Alarms
3. Display Sanity
1. Error
2. Warning
2. Statistics [E1/T1]
1. Bundles statistics
1. Bundle Number
2. Mode
1. Clear
2. Display
2. Voice statistics
1. Time Slot
2. Mode
1. Clear
2. Display
3. Voice Rx Signaling statistics
4. Voice Tx Signaling statistics
5. E1/T1 Hdlc statistics
1. Clear
2. Display
6. Serial Port statistics
1. Clear
2. Display
7. Ethernet statistics
1. Clear
2. Display
2. Statistics [FXS]
1. Bundles statistics
1. Bundle Number
2. Mode
1. Clear
2. Display
2. Voice statistics
1. Time Slot
2. Mode
1. Clear
2. Display
3. FXS Signaling statistics
4. Serial Port statistics
1. Clear
2. Display
5. Ethernet statistics
1. Clear
2. Display
Figure C-5. Monitoring and Diagnostics Menus
From
Sheet 1
4. Diagnostics
1. Inject Tone test
1. Time Slot
2. Direction
3. Time Out
4. Activate
2. Loal Loop test
1. Activate
3. Remote Loop test
1. Activate
4. Display Active tests
5. Ping
1. IP Address
2. Number Of Pings
3. Activate
C-5
Chapter C Configuration Menus
C-6
DC Power Supply Connection – Terminal Block Connector
Note: Ignore this supplement if the unit is
AC-powered.
Certain DC-powered units are equipped with a plastic 3-pin
VDC-IN power input connector, located on the unit rear panel.
Different variations of the connector are shown in Figure 1. All are functionally identical.
Supplied with such units is a kit including a mating Terminal
Block (TB) type connector plug for attaching to your power supply cable.
Connect the wires of your power supply cable to the TB plug, according to the voltage polarity and assembly instructions provided below.
A B C
Caution: Prepare all connections to the TB plug before inserting it into the unit’s VDC-IN connector.
Preparing and Connecting the Power
Supply Cable with the TB Plug
Refer to Figure 2 for assistance.
1. Strip the insulation of your power supply wires according to the dimensions shown.
2. Place each wire lead into the appropriate TB plug terminal according to the voltage polarity mapping shown in Figure 4. (If a terminal is not already open, loosen its screw).
Afterwards, tighten close the three terminal screws.
3. Pull a nylon cable tie (supplied) around the power supply cable to secure it firmly to the
TB plug grip, passing the tie through the holes on the grip.
4. Isolate the exposed terminal screws/wire leads using a plastic sleeve or insulating tape, to prevent the possibility of short-circuit.
5. Connect the assembled power supply cable to the unit by inserting the TB plug into the unit’s
VDC-IN connector until it snaps into place.
Typical DC Power
Input Connector
(on unit panel)
Terminal screws
D
20 mm
5 mm
Mating
TB Connector
Plug
Figure 2. TB Plug Assembly
E
Figure 1. TB DC Input Connectors Types
Appearing on Unit Panels
Wire stripping dimensions
See following page for wire mapping
Nylon cable tie
TB plug grip
DC power cable
SUP-221-03/03
Note: Certain TB plugs are equipped with captive screws for securing the assembled cable’s
TB plug to the unit’s VDC-IN connector (C and
E types only). To secure the plug, tighten the two screws on the plug into the corresponding holes on the sides of the input connector as shown in
Figure 3.
DC Power Supply Wire Voltage Polarity
Refer to Figure 4 for proper mapping of the power supply wire leads to the TB plug’s three terminals.
Captive screws
Figure 3. TB Plug with Captive Screws (optional)
TB Connector
Plug
Warning:
• Reversing the wire voltage polarity can cause damage to
the unit!
• Always connect a ground (earth) wire to the TB plug’s
Chassis (frame) Ground terminal. Connecting the unit without a protective ground, or interruption of the grounding (for example, by using an extension power cord without a grounding conductor) can cause harm to the unit or to the equipment connected to it!
0 -48
( )
Chassis (frame)
Ground
+
Positive pole
-
Negative pole
24/48VDC
Figure 4. Power Supply Wire Mapping
to TB Plug
डाउनलोड