WIRING DIAGRAM
Convertible Packaged Heat Pump
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
4. If any of the original wire as supplied with the furnace
must be replaced, it must be replaced with wiring
material having a temperature rating of at least 105°C.
5. For supply wire ampcities overcurrent protection, see
unit rating plate.
WHITE
WHITE
T1
T2
T3
3 PHASE
COMPRESSOR
LEGEND:
FIELD WIRING
LOW VOLTAGE
HIGH VOLTAGE
TO 208/230 VAC
POWER SUPPLY
L3 L2 L1
T3 T2 T1
BLACK
BLACK
BLUE
CCH
BLACK
BLACK
RED
BLACK
ORANGE
R
OUTDOOR
FAN MOTOR
C
S
CAPACITOR
BLUE
208/230 Volt
DEFROST
SENSOR
BLACK
HEATER
PLUG
1
2
3
4
5
8
9
6
7
BROWN ORANGE
BROWN
BROWN
DEFROST BOARD OPERATION:
1 CLOSES DURING DEFROST. RATNG: 1 A MAXIMUM
2 OPENS DURING DEFROST RATING: 2 HP AT 230 VAC MAXIMUM
3 CLOSED WHEN “Y” IS ENERGIZED. OPEN WHEN “Y” IS DEENERGIZED.
PROVIDES “OFF” DELAY TIME OF 5 MIN WHEN “Y” IS DEENERGIZED.
4 WIITH DFT CLOSED AND “Y” ENERGIZED, COMPRESSOR RUN TIME IS ACCUMLATED.
OPENING OF DFT DURING DEFROST OR INTERVAL PERIOD RESETS THE INTERVAL TO 0.
Y1 O E Y2 R W1 C G
BLACK GREEN
HIGH PRESSURE
SWITCH
REVERSING
VALVE SOLENOID
RED
TRANSFORMER
240V 208V
24V
COM
BLUE
YELLOW
RED
ORANGE
BLOWER RELAY
NC
NO C
NOTE: See Installation
Instructions for wiring, application, and
Information concerning accessory Heat Kits and other options.
Three Phase 60Hz
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
TO INDOOR
THERMOSTAT
B G RED
RED
TO DISCHARGE
AIR SENSOR
WHITE
YELLOW
BLUE
YELLOW
BLACK
GREY
GREEN
ECONOMIZER
2
1
4
3
8
7
6
5
9
PLUG
9
8
7
6
5
2
1
4
3
RED
RED
WHITE
ORANGE
BLUE
YELLOW
BLACK
GREY
GREEN
ECONOMIZER
2
1
4
3
7
6
5
PLUG
9
8
9
8
7
6
5
2
1
4
3
BLACK
GREY
T1
T2
T3
T4
T5
BLOWER
MOTOR
G
C
L
N
¢711009¥¤
WHITE
7110090
11/09