Application Note - Magnetic Stripe Reader
Interfacing the Card Reader to a
Microprocessor
The Mag-Tek Card Reader may be interfaced to a
microprocessor unit (MPU) in a number of ways.
Selection of the most suitable method will depend on the
system requirements and the MPU capabilities. The two
most common methods are:
1. Single-bit input programming.
2. USART (Universal Synchronous/Asynchronous
Receiver - Transmitter such as NEC 82C51).
Single - Bit Input Programming
This method of interface does not require any external
chip to implement serial data communication between
the Card Reader and an MPU. This function is done
through a software program that allows the MPU to
transmit and receive data. This process requires some
very time-critical programming. A disadvantage of this
approach is that, while the processor is receiving data
serially, it must totally dedicate itself to the task.
Accurate timing can only be maintained if the program
remains in a tight wait loop without being diverted to
other functions. When programming the MPU, the timing
loops required for receiving data cannot exceed the time
period of the incoming data bits. Table 1 shows the data
rates at card speed of 50 inches per second (ips).
TK1
Bit Rate (bits/sec.)
10,500
Character Rate (char/sec.) 1,500
Table 1 data rates @ 50ips
TK2
3,750
750
TK3
10,500
2,100
USART
The primary advantage of the USART method is that the
MPU is relieved of the critical time-dependent
programming.
The CARD PRESENT signal can be connected to an
input pin on the USART. The DSR input of the USART is
suggested as an input of the CARD PRESENT signal to
the MPU. The serial data input (RXD) of the USART
receives data from the Card Reader. The clock input
(RXC) of the USART is connected to the read STROBE
output of the Card Reader. The USART must be set up
to operate in the synchronous mode with a single sync
character. This sync character must be equivalent to the
Start Sentinel character of the track that is being read.
When reading Track 1, the user may set the parity on
the USART to ON or OFF. If parity is set to Enabled,
then the word size must be set to 6 bits. In this case the
USART checks the character for parity error. If the user
prefers the parity to be checked by the MPU and not the
USART then parity must be set to Disabled and word
size must be set to 7 bits. When reading Track 2 or
Track 3, parity must be set to OFF. This is because data
characters encoded on these two tracks are in 5 bit
words, including parity. The USART is limited to a
minimum word size of 5 bits only when parity is OFF. In
this case, the USART treats the parity bit just like any
other data bit, and the MPU should check for correct
parity on each character.
In operation, the USART remains inactive until it
recognizes the Start Sentinel character. Then it
becomes active and collects the data characters, frames
the data, and presents it to the MPU. (In some
applications, this may not be suitable for reliable Start
Sentinel detection; see the Detecting Start Sentinel
discussion below.)
When using either method, after the CARD PRESENT
signal indicates that the card is gone, the MPU should
perform error detection by checking both the parity of
each character and of the Longitudinal Redundancy
Check (LRC) character. To perform the LRC calculation,
each bit of each character excluding the parity bit should
be exclusive ORed with the respective bit of all
characters, including Start Sentinel and End Sentinel.
Exclusive ORing the parity bit of all characters does not
generate the parity bit for the LRC character; it is the
parity bit for the LRC character.
The Start Sentinel and the End Sentinel characters
frame data. The first bits encountered by the Card
Reader are the leading zeros. They indicate to the
Reader the presence of an encoded magnetic stripe
card, and allow the Reader to synchronize itself with the
incoming data bits. The leading zeros are followed by
the Start Sentinel character, which indicates the
beginning of data on a track. The characters following
the Start Sentinel represent the data. The End Sentinel
Character indicates the end of data. After the End
Sentinel is the Longitudinal Redundancy Check (LRC)
character. Trailing zeros follow the LRC and fill the
remainder of the track.
NOTE: Characters are encoded on the magnetic stripe
with the least significant bit recorded first. The Start
Sentinel character on Track 2 is recorded as 11010. The
bit pattern is B0 B1 B2 B3 P. The least significant bit is B0.
B3 is the most significant bit. P is the parity bit. As
defined in the ANSI x4.16 1983, ODD parity is required.
The conventional representation of the Start Sentinel
would be 01011 (P B3 B2 B1 B0) or 0Bh (hex).
Note: For bidirectional reading, a USART cannot be
used to identify the Start Sentinel. The USART must be
programmed to begin capturing data based on the first
binary 1 that is found. Set the word length to one byte (8
bits) and disable parity checking; for track 2, the word
size should be no more than 5 bits.
Notes:
1. Card Present, Data, and Strobe are negative true logic.
2. Card Present goes low after 14-15 head flux reversals.
3. Card Present returns to high level approximately 150mS after the
last flux transition.
4. Data is valid 1.0µS (min.) before the leading negative edge of
strobe and remains valid until approximately 1.0µS before the
next STROBE.
Detecting Start Sentinel
In some cases, random noise on a blank track
(especially High Coercivity media) may be detected as a
Start Sentinel. If a Start Sentinel is erroneously detected
then parity and/or LRC checking would undoubtedly
indicate that the track, although blank, actually has an
error on it. For this reason, it is suggested that some
number of the leading zeros be included in the detection
of Start Sentinel. The location of the Start Sentinel and
the number of zeros required to synchronize the read
circuitry determine the number of detectable zeros prior
to the Start Sentinel. In the worst case, there may be no
more than four leading zeros on track 2 and no more
than nine on tracks 1 and 3. In other words, the Start
Sentinel on track 2 should be considered as a 9-bit
value: 4 bits of zero and 5 bits of Start Sentinel.
Bidirectional Reading
In many of today’s magnetic stripe card applications,
reading the card in both directions is necessary.
Programming for bidirectional reading has its own
special requirements. First, the data acquired from the
reader must be treated in memory as a collection of bits
(see note below). Since the direction is not known, the
program must search the bits looking for the Start
Sentinel. If the first character is not the Start Sentinel,
then you must move to the other end of the memory and
begin searching the bits in reverse order for the Start
Sentinel. However, if a Start Sentinel is found, it is
possible that the character is LRC. You may check for
this by determining if the next character is the End
Sentinel. If the next character is the End Sentinel, then
you must move to the other end of memory and begin
searching the bits in the reverse order as discussed
above. The important point is to realize that the LRC
could appear to be a false Start Sentinel.
If the message does not meet the requirements for a
correct recording (the sentinels, party & LRC) then try to
interpret the message in the other direction. The card is
unreadable only after the software has tried both
directions.
Converting Card Data to ASCII
Data
The data transmitted or received by the user’s device is
in ASCII. The data encoded on the cards, however, is in
a different format called Card Data. All RS-232 Mag-Tek
equipment automatically converts transmitted and
received data from ASCII to Card Data. The procedure
for converting ASCII to Card Data is described bellow.
Track 1
Card data on Track 1 consists of six binary bits and an
odd parity bit for each character. A method for
converting ASCII characters to six-bit Card Data (the
parity bit is not included in the calculation) is to subtract
20h (hex) from the equivalent 0 parity ASCII character
(see Character Conversion Chart). For example, the
ASCII character that represents the percent sign (%) is
25h. Subtract 20h from 25h and the result is 05h, which
represents the six-bit portion of the card data code for
the percent sign. An odd parity bit must be added to the
six-bit portion of the character to complete the Card Data
code. A method for converting card data to ASCII
characters is to remove the parity bit from the Card Data
code, then add 20h to the remaining six-bit portion of the
character. The result will be the 0 parity ASCII character.
Track 2 & 3
Card data on Track 2 & 3 consists of four binary bits and
an odd parity bit for each character. A method for
converting ASCII characters to four-bit Card Data (again
the parity bit is not included in the calculation) is to
subtract 30h from the equivalent ASCII character. For
example, the ASCII character that represents the
number 7 is 37h. Subtract 30h from 37h and the result is
07h, which represents the four-bit portion of the card
data code for the number 7. An odd parity bit must be
added to the four-bit portion of the character to complete
the Card Data code. A method for converting card data
to ASCII characters is to remove the parity bit from the
Card Data code, then add 30h to the remaining four-bit
portion of the character. The result will be the 0 parity
ASCII character.