Algas-SDI TORREXX vaporizer Operations & Maintenance Manual
PDF
Document
Publicitate
Publicitate
...Innovative liquid vaporizing and gas mixing solutions Vertical electric single core vaporizer Operations & Maintenance Manual 151 South Michigan Street, Seattle, Washington, USA 98108 Tel: 206-789-5410 Fax: 206-789-5414 Web: www.algas-sdi.com FILE: MANUAL PN 52368 REV 05-15-09 TORREXX.doc 2009.12.03 17:06:42 -08'00' WARNING Read the OPERATION MANUAL before operating this equipment. Ŷ NOTE: Algas-SDI reserves the right to use alternate manufacturers’ components as vendor delivery applicability dictates. Vendors have supplied literature contained in the Operation Manual. Please check to be sure supplied data matches your configuration. Contact Algas-SDI if any questions exist. Ŷ This equipment uses LPG - a flammable fuel, or NH3 - a toxic gas, (depending on the model), handled under pressure. Inherent hazards exist and a thorough understanding of the equipment is required to allow safe operation and maintenance. Ŷ Allow only a TRAINED and FULLY QUALIFIED PERSON to service this equipment. Ŷ Any time a component must be replaced use the same type, model etc. DO NOT SUBSTITUTE! The consequence from such actions is unpredictable and may lead to dire consequences. When components are replaced with components not approved for use in our FM/CSA listed equipment, the FM/CSA listing becomes void for that unit. WARRANTY REGISTRATION To register your new equipment: Visit Algas-SDI's web site at: algas-sdi.com, then click on the "Tech Support" button. Select online Registration or print out the Acrobat Warranty Registration. OR Fill out the Warranty Registration information on the last page of this manual. Then make a photocopy and mail to the address shown at the bottom. WARRANTY, COPYRIGHTS AND APPROVALS WARRANTY Algas-SDI International, LLC (ASDI) warrants that the equipment is free of defects in materials and workmanship under normal use and service. ASDI agrees to repair or replace, at our option, without charge f.o.b. factory, any part which has proven defective to the satisfaction of Algas-SDI International, LLC within one (1) year from the date of the original installation or within 18 months from the date of shipment, whichever is earlier. Equipment, which in the opinion of ASDI, has been damaged by improper installation or operation, or has been abused or tampered with in any way, will not be accepted for return under warranty. Algas-SDI International, LLC will not accept back charges for work performed by others upon or in conjunction with ASDI equipment, unless prior authorization is given by means of an Algas-SDI International, LLC purchase order. Algas-SDI International, LLC will not be liable by reason of shutdown, non-operation or increased expense of operation of other equipment, or any other loss or damage of any nature, whether direct or consequential, arising from any cause whatsoever. Algas-SDI International, LLC makes NO other warranty of any kind, whatsoever expressed or implied; and all warranties of merchantability and fitness for a particular purpose are hereby disclaimed by Algas-SDI International, LLC and excluded from these terms of sale. No person has any authority to bind AlgasSDI International, LLC to any representation or warranty other than this warranty. COPYRIGHT Copyright 2009 by Algas-SDI International, LLC, Seattle, Washington 98108. All rights reserved. No part of this manual may be reproduced or copied in any form or by any means, photographic, electronic, or mechanical, without the prior express written consent from Algas-SDI International, LLC, Seattle, Washington, USA. APPROVALS SYMBOLS AND CONVENTIONS ______________________________ Special symbols are used to denote hazardous or important information. You should familiarize yourself with their meaning and take special notice of the indicated information. Please read the following explanations thoroughly. GENERAL WARNING OR CAUTION This symbol indicates hazards or unsafe practices, which can result in damage to the equipment or cause personal injury. Use care and follow the instructions given. FLAMMABLE GAS HAZARD This symbol indicates a potential hazard, which can result in severe personal injury or death. Use extreme care and follow the instructions given. ELECTRICAL DISCONNECT REQUIRED This symbol indicates a potentially dangerous situation, which can result in severe personal injury or death or damage to equipment. Use great care and follow the instructions given. ASDI CONTACT NUMBERS If you have questions, need help with your equipment, or want information on other products, contact Algas-SDI at: Telephone: 206.789.5410 Facsimile: 206.789.5414 Email: [email protected] Internet: http://www.algas-sdi.com TORREXX TABLE of CONTENTS 1. INTRODUCTION DESCRIPTION 1-1 Figure 1 – TORREXX Dimensional Drawing (LPG Version) 1-2 Figure 2 – TORREXX Dimensional Drawing (NH3 Version) 1-3 TORREXX OPTIONS – INTRODUCTION 1-4 2. MAJOR COMPONENTS DESCRIPTION 2-5 Figure 3 – Heating system 2-5 Figure 4 – Liquid Passage Prevention system 2-6 MAJOR COMPONENTS LIST Figure 5 – TORREXX Major Components Drawing (LPG CONFIGURATION) 2-7 2-7 3. INSTALLATION GENERAL 3-8 Figure 6 – Typical TORREXX Installation Drawing with Pump & Vapor Bypass 3-8 Figure 7 – Typical TORREXX Installation Drawing with Vapor Bypass and No Pump 3-9 Figure 8 – Typical TORREXX Installation Drawing with Economy Operation and Vapor Bypass 3-9 Figure 9 – Typical TORREXX Installation Drawing for Manifolding 2 Vaporizers 3-10 Figure 10 – Typical TORREXX Installation Drawing for Manifolding 3 Vaporizers 3-10 LIQUID LINE 3-11 LIQUID PUMP 3-11 VAPOR LINE 3-11 SAFETY RELIEF VALVE 3-12 ELECTRICAL SERVICE 3-12 DETERMINING WIRE SIZE 3-12 Table 1 – Wire Length Chart (#4 AWG) 3-13 Table 2 – Wire Length Chart (#6 AWG) 3-13 Table 3 – Wire Length Chart (#8 AWG) 3-14 Table 4 – Wire Length Chart (#10 AWG) 3-14 Table 5 – Liquid Temperature vs. Tank Pressure Chart 3-15 Table 6 – LPG liquid line sizing chart (Minimum Pipe Size) 3-16 Table 7 – Equivalent Pipe Length of Various Valves and Fittings (Length in Feet/Meters) 3-16 TORREXX TABLE of CONTENTS - Continued 4. OPERATION GENERAL 4-17 OPERATING INSTRUCTIONS 4-17 STARTING THE VAPORIZER 4-18 STOPPING THE VAPORIZER 4-18 5. MAINTENANCE GENERAL 5-19 CONTACTOR REPLACEMENT SCHEDULE TM Liqui-SAFE VALVE – PERFORMANCE CHECK (6 MONTHS) Figure 11 – Steps to check the Liqui-SAFE TM Liqui-SAFE 5-20 TM valve operation VALVE – SERVICE INSTRUCTIONS 5-21 5-21 5-22 TM Figure 12A – STEP 1 – Be sure that the Liqui-SAFE valve is at the close position as shown 5-22 Figure 12B – STEP 2 – Unscrew reset button base and remove spring 5-22 Figure 12C – STEP 3 – Replace button post internal o-ring 5-23 Figure 12D – Full hook o-ring tool 5-23 Figure 12E – STEP 4 – Unscrew valve latch body 5-23 Figure 12F – STEP 5 – Remove drive magnet and e-clip 5-24 Figure 12G – STEP 6 – Remove spring, valve stem guide and valve stem. Replace o-ring 5-24 Figure 12H – STEP 7 – Replace valve seat and valve stem base o-rings 5-24 6. TROUBLESHOOTING TROUBLESHOOTING TREES 6-25 TREE 0 – What is the problem? TM TREE 1 – Liqui-SAFE 6-25 valve trips 6-26 TREE 2 – Vaporizer does not start 6-27 FULL LOAD VOLTAGE CHECK Figure 13 – Full load voltage check FULL LOAD CURRENT CHECK Figure 14 – Full Load Current Check 6-29 6-29 6-30 6-30 TORREXX ELECTRIC VAPORIZER DATA SHEET 6-31 HEATER CORE RESISTANCE 6-32 Figure 15 – Heater Core Resistance Wiring Connections SOLENOID VALVE LEAK TEST Figure 16 – Solenoid Valve Leak Test Components 6-32 6-33 6-33 TORREXX TABLE of CONTENTS - Continued SOLENOID VALVE ELECTRICAL TEST Figure 17 – Solenoid Valve Electrical Test THERMOCOUPLE SENSOR REPLACEMENT 6-34 6-34 6-35 Figure 18 – TORREXX Box showing Thermocouple location 6-35 Figure 19 – Thermocouple Sensor with Bayonet Style Retainer 6-36 7. TORREXX OPTIONS ECONOMY OPERATION Figure 20 – TORREXX Economy valve installation TORREXX ECONOMY VALVE MAINTENANCE 7-37 7-37 7-38 Figure 21A – STEP 1 – Unscrew the Inlet Housing from the Outlet Housing 7-38 Figure 21B – STEP 2 – Replace the two O-rings, apply excess o-ring grease. 7-38 Figure 21C – STEP 3 – Clean all o-ring contact surfaces and the bottom surface of the Outlet Housing. Apply excess o-ring grease 7-39 Figure 21D – STEP 4 – Clean all piston surfaces. Apply excess grease on o-rings 7-39 Figure 21E – STEP 5 – Make sure that the Pin Hole is clear and The Spring is undamaged. Carefully reassemble all the parts. Apply lubrication grease on straight threads if necessary 7-39 MERCURY RELAY 7-40 TX REMOTE BOX 7-40 VALVE AND STRAINER PACKAGE 7-41 FILTAIRE – CONTAMINANT SEPARATOR 7-41 Figure 22 – Filtaire Operation 7-41 APPENDIX A – TECHNICAL INFORMATION ASCO VALVE USED BY ASDI TORREXX LPG VAPORIZER DATA SHEET (FM) TORREXX ELECTRIC VAPORIZER SPARE PARTS AND ACCESSORIES (FM) Figure 23 – TORREXX ELECTRIC VAPORIZER MAJOR COMPONENTS AND ACCESSORIES TORREXX AMMONIA VAPORIZER DATA SHEET (FM) TORREXX ELECTRIC VAPORIZER SPARE PARTS AND ACCESSORIES (FM) - AMMONIA TORREXX LPG VAPORIZER DATA SHEET (NEMKO) TORREXX ELECTRIC VAPORIZER SPARE PARTS AND ACCESSORIES (NEMKO) TORREXX AMMONIA VAPORIZER DATA SHEET (NEMKO) HEATER BUSSING DIAGRAMS COMPONENT SPECIFICATION Warranty Registration – Refer to the nameplate on the unit to fill out the product registration. Then photocopy and mail to address shown. INTRODUCTION 1 DESCRIPTION The dimensional drawing (see below) identifies the various components of the Algas-SDI TORREXX vaporizer. Multiple resistance heating elements provide thermal energy to the finned aluminum heat exchanger. A solid state controller monitors the heat exchanger temperature and regulates the operating temperature to a predetermined set point. The controls consist of 2 individual Ktype thermocouple sensors with independent high temperature limits. One sensor monitors operating temperature and the other controls the liquid inlet solenoid valve. The liquid inlet solenoid valve does not open until a predetermined warm-up temperature is reached. The vaporizer reaches operating temperature in approximately 60 seconds from a cold start. The vaporized LPG rises into the vapor header and exits through the vapor outlet. The Liqui-SAFETM Valve is specially developed to prevent liquid from going downstream. The TORREXX Vaporizer can be configured for many applications. 1-1 i Standard configuration for Class I, Division 1, Group D for use with propane and LPG applications, FM and cFM approvals i European configuration for propane and LPG, NEMKO & CE mark. i Feedback configuration for Class I, Division 1, Group D for Propane, LPG and Ammonia (NH3 Version) for tank heater applications were adequate tank pressure must be maintained. i Ammonia (NH3 Version) configuration for Class I, Division 1, Group D applications with FM and cFM approval for use with ammonia. i The TORREXXTM vaporizer can be manifolded together for increased capacity on a single skid. Consult Algas-SDI for Configuration information. i The TORREXXTM vaporizer can be packaged with an Algas-SDI mixing system on a single skid. Consult Algas-SDI for Configuration information. i For customizing the TORREXXTM vaporizer to your requirements consult Algas-SDI for information. ASDI Operations and Maintenance – TX Models – P/N: 52368 Figure 1 – TORREXX Dimensional Drawing (LPG Version) (4) ½” DIA MOUNTING HOLES MODEL TX25 A PRESSURE RELIEF VALVE TX50 TX100 41” 1040mm TX160 TX240 47” 52” 1190mm 1320mm TX320 59” 1500mm Liqui-SAFE VALVE 1” FNPT VAPOR OUTLET INSULATION JACKET PRESSURE GAUGE FLOAT HEATER ELEMENT TEMPERATURE CONTROL SENSOR INLET SOLENOID VALVE CONTROL HOUSING ELECTRICAL SERVICE REQUIRED 1”FNPT ASDI Operations and Maintenance – TX Models – P/N: 52368 1-2 Figure 2 – TORREXX Dimensional Drawing (NH3 Version) (4) ½” DIA MOUNTING HOLES MODEL A TX19AA TX38AA TX75AA 41” 1040mm Liqui-SAFE VALVE TX120AA TX180AA TX240AA 47” 1190mm 52” 1320mm 59” 1500mm STAINLESS STEEL VAPOR OUTLET ALUMINUM RELIEF VALVE WITH PIPEAWAY ADAPTER INSULATION JACKET FLOAT HEATER ELEMENT TEMPERATURE CONTROL SENSOR ELECTRICAL SERVICE REQUIRED 1”FNPT 1-3 CONTROL HOUSING ASDI Operations and Maintenance – TX Models – P/N: 52368 TORREXX VAPORIZER OPTIONS Your TORREXXTM vaporizer may be equipped with one or several of the factory options. All the options can be integrated to your TORREXXTM vaporizer and are designed to enhance convenience to the user. Below is a brief introduction to the options available for the TORREXXTM vaporizer. See SECTION 8 of this manual or contact Algas-SDI for more information. 1) Valve and Strainer Package – This kit includes the correct sized ball valve, globe valve and strainer for the vaporizer installation. 2) Contaminant Separator (Filtaire) – The Algas-SDI FiltaireTM is a filtering device design to trap heavy hydrocarbons commonly present in LPG gas vapor. It also traps other materials, which may be in the gas due to storage conditions and internal condition of the equipment. 3) Pipe Away Adapter – Allows relief valve to be piped away. 4) TORREXX Stand – Elevates TORREXX Vaporizer 1 foot off the ground for access and protection from the elements. 5) Stabilaire Pump Package – Consult factory 6) Economy – Consult factory 7) Remote Control – Consult Factory ASDI Operations and Maintenance – TX Models – P/N: 52368 1-4 MAJOR COMPONENTS 2 Your New TORREXXTM vaporizer is designed to be reliable and user friendly. Several features allow you to quickly determine the status of your vaporizer. There are two basic control systems within a TORREXXTM: 1) Heating system – Figure 3 2) Liquid Passage Prevention system – Figure 4 Figure 3 – Heating system x x x x SELF REGULATING HEATER SYSTEM NO START/STOP SWITCHES ENGAGES AUTOMATICALLY JUST APPLY POWER TO TURN VAPORIZER ON TEMPERATURE ACTIVATED CIRCUIT OPENS AT 55C OR 131F WITH SOLENOID VALVE TO ENSURE AUTOMATIC RESTART AFTER POWER INTERRUPTION TEMPERATURE CONTROLLER DETECTS HEAT EXCHANGER TEMPERATURE VIA A DUAL TYPE K THERMOCOUPLE HEAVY DUTY CONTACTOR TX100 SHOWN (CE CONFIGURATION) WITH NO OPTIONS 2-5 ASDI Operations and Maintenance – TX Models – P/N: 52368 Figure 4 – Liquid Passage Prevention system x x RED FLAG INDICATES STATUS VALVE IS TRIPPED WHEN FLAG IS UP (AS SHOWN) CLEAR PROTECTIVE BUTTON KEEPS DEBRIS, WATER OR ICE FROM IMPEDING PROPER OPERATION VALVE IS SET WHEN FLAG IS DOWN (AS SHOWN) x x FLOAT BALL ACTIVATED MANUAL RESET Liqui-SAFE VALVE DETECTS AND PREVENTS LIQUID FROM PASSING THE Liqui-SAFE VALVE CAN BE MANUALLY TRIPPED TO VERIFY CLOSING INTEGRITY FLOAT BALL TX100 SHOWN (FM/cFM CONFIGURATION) WITH NO OPTIONS ASDI Operations and Maintenance – TX Models – P/N: 52368 2-6 Figure 5 – TORREXX Major Components Drawing (LPG CONFIGURATION) 1) Liquid Inlet Solenoid Valve 2) Valve, Gauge and Strainer kit components (Optional) 3) Mercury Relay kit (Optional) 4) Control Circuit Board 5) Economy Valve (Optional) 6) Liqui-SAFETM Valve with manual reset 7) Insulation Jacket 8) Contactor 2-7 ASDI Operations and Maintenance – TX Models – P/N: 52368 3 INSTALLATION GENERAL Install the ASDI TORREXX vaporizer on a level firm base at least 6” above grade and secure it through the four ½” holes. Protect the equipment against damage by moving vehicles by use of an appropriate barrier. Consult state, provincial, insurance carriers, and local authorities for installation requirements. Clean all foreign material from all pipelines prior to making final connections. All joints require a pipe sealant approved for LPG, depending on type of service. Test for leaks using an inert gas, such as compressed carbon dioxide or nitrogen, at 1½ times the working pressure or as required by applicable codes. Check all connections using an appropriate leak detection solution or device. Even very small leaks are unacceptable. Eliminate all leaks prior to operation. Install in accordance with applicable codes and local regulations as required. Figure 6 - Typical TORREXX Installation Drawing with Pump & Vapor Bypass NOTES 1. 2. 3. 4. TANK VAPOR PRESSURE REGULATOR* LIQUID PIPING LOSSES BETWEEN VAPORIZER AND THE TANK MUST NOT EXCEED HYDROSTATIC HEAD WHEN THE PUMP IS SHUT OFF. INSTALL VAPORIZER 1ST STAGE REGULATOR UPSTREAM OF THE TANK VAPOR PRESSSURE CONNECTION POINT. SET 1ST STAGE VAPORIZER REULATOR 2-4 PSIG HIGHER THAN TANK VAPOR PRESSURE REGULATOR SET-POINT. NO CHECK VALVES IN LIQUID LINE. LIQUID MUST BE ABLE TO FLOW IN BOTH DIRECTIONS *BY OTHERS VAPOR BY-PASS LINE ISOLATION VALVE* VAPORIZER REGULATOR* PRESSURE GAUGE* (VAPOR) TO LOAD STORAGE TANK OUTLET ISOLATION VALVE” STRAINER WITH MAGNET FOR IRON PARTICLE PICK-UP* SEAL OFF REQUIRED* ELECTRIC SERVICE REQUIRED LIQUID OPTIONAL ISOLATION VALVE W/HYDROSTATIC RELIEF* Note: The vapor bypass line is not required except when you have the Economy Operation option. In other installations, it is recommended because it will provide vapor from the tank to the load in case of vaporizer failure or power failure but it is not required. The vaporizer will operate properly without the bypass. ASDI Operations and Maintenance – TX Models – P/N: 52368 3-8 Figure 7 - Typical TORREXX Installation Drawing with Vapor Bypass and No Pump NOTES 1. LIQUID PIPING LOSSES BETWEEN VAPORIZER AND THE TANK MUST NOT EXCEED HYDROSTATIC HEAD WHEN THE PUMP IS SHUT OFF. INSTALL VAPORIZER 1ST STAGE REGULATOR UPSTREAM OF THE TANK VAPOR PRESSSURE CONNECTION POINT. ST SET 1 STAGE VAPORIZER REULATOR 2-4 PSIG HIGHER THAN TANK VAPOR PRESSURE REGULATOR SET-POINT. NO CHECK VALVES IN LIQUID LINE. LIQUID MUST BE ABLE TO FLOW IN BOTH DIRECTIONS 2. 3. 4. TANK VAPOR PRESSURE REGULATOR* ISOLATION VALVE* *BY OTHERS VAPOR BY-PASS LINE OUTLET ISOLATION VALVE” STORAGE TANK (VAPOR) TO LOAD PRESSURE GAUGE* STRAINER WITH MAGNET FOR IRON PARTICLE PICK-UP* VAPORIZER REGULATOR* SEAL OFF REQUIRED* LIQUID ELECTRIC SERVICE REQUIRED ISOLATION VALVE W/HYDROSTATIC RELIEF* ISOLATION VALVE” Figure 8 - Typical TORREXX Installation Drawing with Economy Operation and Vapor Bypass NOTES 1. LIQUID PIPING LOSSES BETWEEN VAPORIZER AND THE TANK MUST NOT EXCEED HYDROSTATIC HEAD WHEN THE PUMP IS SHUT OFF. 2. INSTALL VAPORIZER 1ST STAGE REGULATOR UPSTREAM OF THE TANK VAPOR PRESSSURE CONNECTION POINT. 3. SET 1ST STAGE VAPORIZER REULATOR 2-4 PSIG HIGHER THAN TANK VAPOR PRESSURE REGULATOR SET-POINT. 4. NO CHECK VALVES IN LIQUID LINE. LIQUID MUST BE ABLE TO FLOW IN BOTH DIRECTIONS VAPOR BY-PASS LINE *BY OTHERS TANK VAPOR PRESSURE REGULATOR* ISOLATION VALVE* OUTLET ISOLATION VALVE* PRESSURE GAUGE* (VAPOR) TO LOAD ASDI ECONOMY VALVE SENSES UPSTREAM PRESSURE (OPEN 30PSIG CLOSED 60PSIG) PRESSURE GAUGE* STORAGE TANK VAPORIZER REGULATOR* STRAINER WITH MAGNET FOR IRON PARTICLE PICK-UP* SEAL OFF REQUIRED* ELECTRIC SERVICE REQUIRED ISOLATION VALVE W/HYDROSTATIC RELIEF* LIQUID ISOLATION VALVE” Note: Economy option cannot be used on an installation that requires a pump. 3-9 ASDI Operations and Maintenance – TX Models – P/N: 52368 Figure 9 – Typical TORREXX Installation Drawing for Manifolding 2 Vaporizers Liqui-SAFE VALVE VAPOR OUT EQUAL PIPE LENGTH TORREXX VAPORIZER (TYP) USE 1” UNION AND BALL VALVE WITH BALANCING ORIFICES EQUAL PIPE LENGTH LIQUID IN LIQUID INLET STRAINER W/MAGNET FOR IRON PARTICLE PICK-UP Figure 10 – Typical TORREXX Installation Drawing for Manifolding 3 Vaporizers VAPOR OUT Liqui-SAFE VALVE EQUAL PIPE LENGTH TORREXX VAPORIZER (TYP) USE 1” UNION AND BALL VALVE WITH BALANCING ORIFICES (ALL VAPORIZER OUTLETS) LIQUID INLET STRAINER W/MAGNET FOR IRON PARTICLE PICK-UP EQUAL PIPE LENGTH ASDI Operations and Maintenance – TX Models – P/N: 52368 LIQUID IN 3-10 LIQUID LINE Size the liquid line from the storage tank to the vaporizer to supply the vaporizer at full capacity with a minimal pressure drop. A liquid linesizing chart is provided in Table 6. Install a liquid line strainer with magnet for iron particle pickup at the vaporizer inlet. CAUTION A liquid pump must be installed if the pressure drop in the liquid line between the vaporizer and the tank exceeds the hydrostatic liquid head in the storage tank. ONE FOOT OF LIQUID PROPANE EQUALS .21 PSI! Liquid line frosting is a sure indication of too much pressure drop in the liquid line. LIQUID PUMP Is a Liquid Pump necessary? What are your vapor pressure requirements? Pressure in the storage tank depends on temperature See Table 5. A good “rule of thumb” for determining when a Liquid Pump is necessary is this: If the storage pressure will not always exceed the required distribution pressure by 5 psig (0.35 kg/cm2), a pump is necessary. Install an ASDI STABILAIRE Liquid Pump in the liquid line close to the storage tank. To prevent cavitation, place the liquid strainer at least five feet upstream of the pump inlet. Typically a pump is not required unless a mixing system is used or temperature at the installation will be extremely low, causing the pressure to drop below the required process pressure. VAPOR LINE Install an appropriate regulator immediately downstream of the vapor outlet port. Pipe from the outlet port of the regulator to the distribution system. Further reduction of downstream pressure requires a “Second Stage” regulator close to the consuming equipment. Properly sized piping and regulators will insure satisfactory service. NOTE For safety reasons both FIRST and SECOND stage regulators must be 250 psig (17.58 cm/kg2) inlet pressure rated! 3-11 ASDI Operations and Maintenance – TX Models – P/N: 52368 SAFETY RELIEF VALVE If the vaporizer is to be installed within an enclosure or building, VENT THE SAFETY RELIEF VALVE OUTSIDE THE ENCLOSURE AND REDIRECT THE DISCHARGE UPWARD. A pipe-away adapter must be used at the relief valve. Always install a rain-cap or similar device to prevent water and other debris from entering the relief discharge. If water enters, it may freeze and prevent the relief valve from proper discharge, creating a potentially hazardous situation. ELECTRICAL SERVICE The rating plate on the vaporizer and the data sheet provided with the manual provides your specific vaporizer’s electrical power requirements and the drawing numbers of the appropriate wiring diagrams and schematics. This unit is constructed to meet NFPA 70 Class I, Division 1, Group D requirements. All wiring to the unit, including the ground connection, must meet the applicable codes for the area in which it is being installed. Wire size and type must comply with the applicable codes for the area in which it is being installed. The Tables 1 through 4 list the recommended wire size for the different models. Those tables are to be used as guides only. Provide a fused disconnect outside of the classified area. If it is not within sight of the vaporizer, the fused disconnect must have a locking device. Run wire within rigid conduit, and install a seal-off at the connection of the field conduit to the vaporizer. WIRE SIZE When selecting the type and size of wire used to install the TORREXX series electric vaporizers, please take into account the following environmental information: Ŷ Maximum enclosure surface temperature: 65º C (150ºF). Ŷ Maximum enclosure ambient temperature: 65º C (150ºF). Ŷ Maximum temperature allowed at contactor terminals: 90º C (195º F). Ŷ Current draw of vaporizer: Indicated on vaporizer rating plate and on the data sheet. Ŷ Contactor terminal lug wire size range: #2 - 10. As the length of the wire run affects the overall wire size requirements, always refer to NFPA 70 (NEC) for proper wire selection. Several wire-sizing charts have been provided for determining the size of wire required due to load and length of wire. When installing the wire it is important to have a good connection at the terminal lugs. Loose terminals may cause an excessive temperature rise at the terminal lugs, which can lead, to premature contactor failure, transformer failure, and/or overheating and possible destruction of the transformer. For this reason it is strongly recommended that the wire terminations be checked and re-tightened periodically to prevent excessive overheating at the terminals due to loose connections. ASDI Operations and Maintenance – TX Models – P/N: 52368 3-12 Table 1 – Wire Length Chart [#4 AWG] Table 2 – Wire Length Chart [#6 AWG] 3-13 ASDI Operations and Maintenance – TX Models – P/N: 52368 Table 3 – Wire Length Chart [#8 AWG] Table 4 – Wire Length Chart [10 AWG] ASDI Operations and Maintenance – TX Models – P/N: 52368 3-14 Table 5 – Liquid Temperature vs. Tank Pressure Chart Liquid Temperature Propane Butane Ammonia Tank Gauge Pressure Tank Gauge Pressure Tank Gauge Pressure °F °C PSI kPa -43.73 -40 -30 -30 -25 -20 -15 -10 -41.65 -39.6 -36.85 -34.1 -31.35 -28.6 -25.85 -23.1 0 1.3952 3.421 5.639 8.06 10.697 13.561 16.666 0 9.6196 23.5871 38.877 55.57 73.751 93.503 114.91 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 -20.35 -17.6 -14.85 -12.1 -9.35 -6.6 -3.85 -1.1 1.65 4.4 7.15 9.9 12.65 15.4 18.15 20.9 23.65 26.4 29.15 31.9 34.65 37.4 40.15 42.9 45.65 48.4 51.15 53.9 56.65 59.4 20.024 23.648 27.551 31.747 36.248 41.068 46.222 51.723 57.586 63.825 70.455 77.49 84.945 92.836 101.179 109.988 119.28 129.0715 139.737 150.215 161.603 173.558 186.098 199.241 213.007 227.414 242.483 258.235 274.691 291.875 136.06 163.05 189.96 218.88 249.92 283.15 318.69 356.67 397.04 440.06 485.77 534.27 585.68 640.08 697.6 758.34 822.4 889.91 963.45 1035.7 1114.21 1196.64 1283.1 1373.72 1468.63 1567.96 1671.86 1780.47 1893.93 2012.4 3-15 PSI kPa NOTE: Below 30°F or -10°C, Butane is a liquid at normal atmospheric pressure. 1.25 2.92 4.82 6.85 9 11.32 13.82 16.5 19.3 22.44 25.81 29.21 32.67 36.67 41.02 46.57 50.28 55.28 60.53 66.13 72.13 78.17 8.6185 20.133 33.233 47.229 62.053 78.049 95.286 113.76 133.07 154.72 177.95 201.4 225.25 252.83 282.82 321.09 346.67 381.14 417.34 455.95 497.32 538.96 PSI kPa 1.234 3.539 6.156 8.968 8.511 24.401 42.648 61.834 12.216 15.622 19.565 23.688 28.424 33.366 39.001 44.867 51.513 58.418 66.035 74.254 83.106 92.622 102.84 113.78 125.49 137.99 151.33 165.54 181.12 196.7 214.235 231.77 251.415 271.06 292.97 314.88 339.21 363.54 84.228 107.710 134.893 163.323 195.977 230.051 268.899 309.347 355.168 402.778 455.295 511.963 572.996 638.606 709.057 784.486 865.223 951.408 1043.384 1141.358 1248.778 1356.199 1477.098 1597.998 1733.445 1868.893 2019.957 2171.021 2338.771 2506.520 ASDI Operations and Maintenance – TX Models – P/N: 52368 Table 6 – LPG liquid line sizing chart (Minimum Pipe Size) Capacity of units MMBTU (Kcal) 1.146 (288,792) 2.292 (557,584) 4.584 (1,155,168) 7.280 (1,834,537) 10.920 (2,751,806) 14.665 (3,668,800) Distance from storage to vaporizer - feet (meters)* Kg 25 50 100 160 240 320 LBS (GPH) 55 (12.5) 110 (25) 220 (50) 352 (80) 530 (120) 530 (160) 25 (8) 50 (15) 75 (23) 100 (31) 150 (36) 200 (61) 300 (92) 400 (122) ½” ½” ½” ½” ½” ¾” ¾” ¾” ½” ½” ½” ¾” ¾” 1” 1” 1” ½” ¾” ¾” ¾” 1” 1” 1” 1¼‘ ¾” ¾” 1” 1” 1” 1¼‘ 1¼‘ 1¼‘ 1” 1” 1¼‘ 1¼‘ 1¼‘ 1½ ” 1½ ” 1½ ” 1” 1” 1¼‘ 1¼‘ 1¼‘ 1½ ” 1½ ” 1½ ” Table 7 – Equivalent Pipe Length of Various Valves and Fittings (Length in Feet/Meters) Globe Valve ½” (1.27 cm) 15.5/4.72 ¾” (1.91 cm) 21/6.40 1” (2.54 cm) 27/8.23 1 ¼” (3.18 cm) 36/10.97 1 ½” (3.81 cm) 43/13.11 Gate Valve 0.6/0.18 0.8/0.24 1/0.30 1.4/0.43 1.6/0.49 Angle Valve 8/2.44 11/3.35 14/4.23 18/5.49 21/6.40 Elbow, 90 1.4/0.43 1.9/0.58 2.4/0.73 3.2/0.98 3.8/1.19 Elbow, 45 0.7/0.21 1/0.30 1.2/0.37 1.6/0.49 2/0.61 Elbow, 90 STR 2.3/0.70 3.1/0.94 4/1.22 5.3/1.62 6.3/1.92 Tee 2.7/0.82 3.7/1.13 4.8/1.46 6.4/1.95 7.5/2.29 Size/Description ASDI Operations and Maintenance – TX Models – P/N: 52368 3-16 4 OPERATION GENERAL The TORREXX Electric Vaporizer utilizes a finned cast aluminum heater core. The heater core contains multiple cast-in resistance heater elements. Multiple wiring configurations allow a variety of AC input voltages to suit local power supply requirements. Liquid LPG enters the vaporizer through the Liquid Inlet Solenoid Valve at the base of the pressure vessel. During operation, a K-type thermocouple temperature sensor and solid state control system maintain the core temperature at 165°F (74°C) for LPG models and 195°F (90°C) for Ammonia models. As the temperature increases on start the Liquid Inlet Solenoid Valve opens at 131°F (55°C) liquid enters the vaporizer and comes in contact with the heater core. Vaporization results as the liquid extracts energy (heat) from the heater core. As the heater core cools, the Temperature Sensor provides a signal to the control system to energize the heater power contactor, applying power to the heater elements. OPERATING INSTRUCTION 1) Complete the installation and leak test. 2) Check current and voltage to verify proper operation of the vaporizer. 3) This unit will not be damaged by operating the unit in a “dry” condition. It is not necessary to have liquid in the unit for testing or evaluation. 4) Normal operating temperature is 165°F (74°C). Use caution when working around vaporizer. 4-17 ASDI Operations and Maintenance – TX Models – P/N: 52368 STARTING THE VAPORIZER CAUTION Do not start the vaporizer when both inlet and outlet hand valves are closed. Pressure can build in the vaporizer during startup and blow the relief valve. 1) Close the outlet isolation valve. 2) Open all valves between the storage tank and the vaporizer to allow liquid flow to the vaporizer when the solenoid valve opens. 3) Power unit. A small “click” should be heard immediately afterwards. The vaporizer heater elements are now energized. It will take approximately 60 seconds for the vaporizer to reach operating temperature. After the unit reaches operating temperature, the Inlet Solenoid Valve would open automatically to allow LPG to enter. Wait approximately 2 minutes so that excess LPG is pushed back to the storage tank. 4) Carefully press the Button on top of the Liqui-SAFETM valve all the way down and SLOWLY release it. A latch mechanism inside the Liqui-SAFETM valve will keep the Red Flag at the down position, indicating the valve is open. 5) The TORREXX vaporizer is now ready to supply vapor. Slowly open the outlet isolation valve to pressurize the supply piping. Then, fully open the outlet isolation valve to allow vapor to flow to the load. The heater will cycle automatically to match the flow conditions. STOPPING THE VAPORIZER 1) Close the outlet isolation valve. 2) Disconnect power. ASDI Operations and Maintenance – TX Models – P/N: 52368 4-18 MAINTENANCE 5 GENERAL The TORREXX vaporizer is designed for long term trouble free operation. Because of the nature of its use, and the severe duty it receives, it is important to provide scheduled maintenance. A list of RECOMMENDED SPARE PARTS is located in the back of this manual. 1) Clean the liquid inlet strainer after the first month of operation. Thereafter, check every 6 months. 2) Annually, make a visual check of the safety relief valve located at the top of the unit. Replace if any sign of leaking is observed. The relief valve is not serviceable in the field. Be sure it is covered with an appropriate plastic cap to prevent rain and debris from entering. 3) Every 6 months, make a performance check on the Liqui-SAFETM valve. Test the shut-off mechanism (See below for instructions). 4) Every two years, replace all the o-rings in the Liqui-SAFETM valve. This service is not serviceable in the field. See “Liqui-SAFETM valve – Service Instructions” below. 5) Annually, change the inlet solenoid diaphragm. See the enclosed Maintenance & Operation sheet for ASCO 2-way valves: Appendix A. 6) Make a visual inspection of the electrical wiring and connections in the control housing every time you inspect the contactor insuring that the connections are tight. See Contactor Replacement Schedule. 5-19 ASDI Operations and Maintenance – TX Models – P/N: 52368 CONTACTOR INSPECTION WARNING The Contactor that powers the heaters produces sparks which may ignite any flammable vapors in the area when the control box cover is removed. If the cover must be removed, shut off the power, remove the cover and check very carefully for fumes, leaks, or any indication of flammable vapors in the atmosphere or in the control enclosure. Do not re-apply power if fumes are present. They may ignite. CAUTION Keep a fire extinguisher available in the immediate vicinity before re-applying power when the control cover is removed. The TORREXX vaporizer utilizes an electro-mechanical contactor to switch power to the heating elements. Since contactors wear out in normal operation, it is prudent industry practice to inspect then on a preventive maintenance basis. Manufacturers define a cycle life for contactors based upon operations at rated current. The cycle rate of the contactor in vaporizers varies due to liquid temperature/pressure, percent loading of the vaporizer, and installation specifics. Vaporizer testing has demonstrated that cycle rates are greatest at around 50% of the vaporizer loading and least when vaporizers are energized in a standby mode. We recommend the following inspection schedule for contactors: i 5000 hours for vaporizers in service i 30,000 hours for vaporizers in standby mode i For vaporizers operating in a combination of service and standby modes, we are providing a simple formula to help determine when contactors should be inspected. Contactor life factor (LF) can be defined as follows: LF= X 5000 + Y _ 30000 When X = hours of vaporizer operation mode Y = hours of vaporizer in standby mode If LF is 1 or greater, the contactor should be replaced. This data is to be used only as a guide. It is not “fool-proof” as the environment your vaporizer operates in and its load may affect the contactor life span. ASDI Operations and Maintenance – TX Models – P/N: 52368 5-20 Liqui-SAFETM valve – Performance check (Every 6 months) I Latch operation. – While the valve is in the open position and the Red Flag is down, press Button and release QUICKLY. This will cause the valve to close and the Red Flag to pop up. Carefully press the Button again all the way down and release SLOWLY. The valve will stay open. II Leak detection. – Follow the instructions in “I” to manually open and close the valve. Perform leak tests in both conditions. If a leak is detected at the Valve Body (Step 1) when the valve is open, replace the Valve Body O-ring. If a leak is detected in Step 5 when the valve is closed (see Figure 11), follow the “Liqui-SAFETM valve – Service Instructions” and change all the o-rings. (This service should not be performed in the field.) Figure 11 – Follow 1 to 7 below to check the Liqui-SAFETM valve operation 2. PRESS AND RELEASE QUICKLY TO CLOSE 6. PRESS AND RELEASE SLOWLY TO RE-OPEN 1. CHECK FOR LEAK (AT GAP) 3. CHECK FOR LEAK (AT PIPE THREADS) 5. CHECK FOR LEAK (AT GAP) STEP 1 4. CHECK FOR LEAK (AT VALVE THREADS) 7. MAKE SURE VALVE FLAG IS DOWN. VALVE IS NOW IN OPERATING POSITION STEP 2 STEP 3 WARNING Extreme caution must be taken due to the potential of flammable vapors being exposed to the atmosphere and create an ignition. Do not operate any equipment that may create a spark from this point. Do not open the explosion-proof enclosure. 5-21 ASDI Operations and Maintenance – TX Models – P/N: 52368 Liqui–SAFETM Valve – Service Instructions There are four (4) o-rings in the Liqui-SAFETM valve and these are the Button Post o-ring, Valve Body o-ring, Valve Seat o-ring and Valve Stem Base o-ring. In order to keep the valve working at its peak conditions, replacement of all the orings according to the maintenance schedule is strongly recommended. Due to the complexity of the valve and the number of parts involved, this service should NOT be done in the field. Follow the 7 Steps below to service the Liqui-SAFETM valve. Clean all the metal parts with WD-40. Re-assemble all the parts. Simulate the tripping action of the valve and verify the tripping force applied on the Extension Stem be less than 0.5lbf (2.22 N). Figure 12A – STEP 1 – Be sure that the Liqui-SAFETM valve is at the closed position as shown Figure 12B – STEP 2 – Unscrew reset button base and remove the spring UNSCREW RESET BUTTON BASE REMOVE SPRING ASDI Operations and Maintenance – TX Models – P/N: 52368 5-22 Figure 12C – STEP 3 – Replace button post internal o-ring COMPRESS SUB-ASSEMBLY TO GAIN BEST ACESS TO THE O-RING. REMOVE USING FULL HOOK O-RING TOOL (SEE FIGURE 12D) REPLACE O-RING EVERY 2 YEARS. APPLY WHITE LITHIUM GREASE PRIOR TO INSERTING BACK IN THE O-RING GROOVE. Figure 12D – Full hook o-ring tool Figure 12E – STEP 4 – Unscrew valve latch body UNSCREW VALVE LATCH BODY NOTE: BE SURE THAT THE VALVE IS IN THE CLOSED POSITION BEFORE UNSCREWING VALVE LATCH BODY. FAILING TO DO SO MAY RESULT IN DAMAGING THE LATCH 5-23 ASDI Operations and Maintenance – TX Models – P/N: 52368 Figure 12F – STEP 5 – Remove drive magnet and e-clip REMOVE MAGNET NOTE: USE CAUTION WHEN REMOVING ECLIP AS THE SPRING IS IN COMPRESSION. HOLD MAGNET HOLDER FIRMLY DURING THE ENTIRE PROCESS. SAFETY GLASSES SHOULD BE USED AS A PRECAUTION. REMOVE E-CLIP USING NEEDLE NOSE PLIERS DEPRESS MAGNET HOLDER AND REMOVE AFTER REMOVING E-CLIP SECURE VALVE STEM SUB-ASSEMBLY TO PREVENT MOVEMENT WHILE DEPRESSING THE MAGNET HOLDER Figure 12G – STEP 6 – Remove Spring, valve stem guide and valve stem. Replace o-ring. REMOVE SPRING REMOVE VALVE STEM REMOVE VALVE STEM GUIDE REPLACE O-RING EVERY 2 YEARS. APPLY WHITE LITHIUM GREASE PRIOR TO INSERTING BACK IN THE O-RING GROVE Figure 12H – STEP 7 – Replace valve seat and valve stem base o-rings. REPLACE O-RINGS EVERY 2 YEARS. APPLY WHITE LITHIUM GREASE TO BOTH O-RINGS PRIOR TO INSERTING BACK IN THE O-RING x x IMPORTANT: When reassembling the valve after servicing o-rings make sure that you apply super glue to the inside of the magnet holder and press the magnet firmly in until it bottoms out. Allow sufficient time for glue to dry. Always perform a functional check and leak test (see Figure 11) of the re-assembled valve to ensure that it actuates per design and that valve seat o-ring seals properly against the valve body. Figure 12F shows proper sealing of valve seat o-ring against valve body that should be observed prior to conducting a leak test. ASDI Operations and Maintenance – TX Models – P/N: 52368 5-24 6 TROUBLESHOOTING General Follow the troubleshooting guide below to identify the problem: WHAT IS THE PROBLEM? Liqui-SAFE TM VALVE TRIPS SEE TROUBLESHOOTING TREE # 1 6-25 VAPORIZER DOES NOT START LIQUID DOWNSTREAM SEE TROUBLESHOOTING TREE # 2 VALVE FAILURE. SERVICE OR REPLACE IF NECESSERARY ASDI Operations and Maintenance – TX Models – P/N: 52368 TREE # 1 TM Liqui-SAFE VALVE TRIPS WARM IS THE UNIT WARM OR COLD? COLD (POWER OFF) RESET THE Liqui-SAFETM VALVE YES DOES THE VALVE STAY OPEN? PERFORM SOLENOID VALVE LEAK TEST (SEE FIG .16) NO YES LEAKAGE DETECTED? NO REPAIR OR REPLACE SOLENOID VALVE UNIT IS WORKING PROPERLY, BUT HAS BEEN OVERDRAWN. RE-ASSESS LOAD REMOVE FOR CLEANING, OR REPLACE IF NECESSARY NO VERIFY CORRECT VOLTAGE SUPPLY AND VAPORIZER RATING. PERFORM FULL LOAD VOLTAGE AND CURRENT CHECK (SEE FIG. 13 AND FIG. 14) PROBLEM FIXED? YES PROBLEM CAUSED BY Liqui-SAFE VALVE FAILURE CONTACT ASDI ASDI Operations and Maintenance – TX Models – P/N: 52368 6-26 TREE # 2A VAPORIZER DOES NOT START CHECK CONTROL BOARD LIGHT GREEN NO LIGHT SEE TROUBLESHOOTING TREE #2B CHECK TRANSFORMER WIRING NO LOSE WIRING? YES BAD WIRING CONNECTIONS. REPLACE OR REPAIR ANY DAMAGED WIRING CHECK TRANSFORMER FUSE NO YES BLOWN FUSE? REPLACE TRANSFORMER AND RESTART UNIT REPLACE FUSE RESTART UNIT NO PROBLEM FIXED? CHECK TRANSFORMER VOLTAGE YES PROBLEM CAUSED BY A BLOWN FUSE VOLTAGE AT TRANSFORMER? NO REPLACE TRANSFORMER RESTART UNIT 6-27 YES REPLACE TEMPERATURE CONTROLLER. RESTART UNIT ASDI Operations and Maintenance – TX Models – P/N: 52368 TREE # 2B VAPORIZER DOES NOT START GREEN YES NO IS CONTACTOR LATCHED? CHECK FUSE LINKS YES FUSE LINKS OPEN? NO REPLACE CONTACTOR PRESS HI-LIMIT BUTTON TO RESET YES FUSE LINKS OPEN? NO YES CONTACT ASDI VAPORIZER STARTS WORKING? NO SEE HEATER CORE RESISTANCE (FIG. 15) CHECK THERMOCOUPLE WIRING REPLACE TEMPERATURE CONTROLLER YES PROBLEM CAUSED BY DAMAGED TEMPERATURE CONTROLLER VAPORIZER STARTS WORKING? REPLACE TEMPERATURE CONTROLLER. RESTART VAPORIZER NO CONTACT ASDI ASDI Operations and Maintenance – TX Models – P/N: 52368 6-28 Full Load Voltage Check NOTE Current flow depends on the applied voltage. Voltage lower than the specified voltage causes low current and may negatively affect operation. Make all measurements with the heater ON (Contactor closed). WARNING These tests include high voltage. Exercise great caution in making the following tests. Carelessness could result in severe injury or death. See additional warnings located at the beginning of this Chapter. FULL LOAD VOLTAGE CHECK Check heater voltage by measuring voltage at the contactor terminals. See Data sheet of your manual or rating plate on the vaporizer to determine the correct voltage reading of your vaporizer. Measure voltage between all connected poles of the contactor. The readings should be equal to +/- 3%. Figure 13 – Full load voltage check POWER IN MEASURE VOLTAGE CONTROL BOARD CONTACTOR 6-29 ASDI Operations and Maintenance – TX Models – P/N: 52368 Full Load Current Check NOTE See fusible link detail below for typical fusible link installation. WARNING These tests include high voltage. Exercise great caution in making the following tests. Carelessness could result in severe injury or death. See additional warnings located at the beginning of this Chapter. Measure the current on each of the heater AC power input wires. See Data Sheet or rating plate provided with your manual for the correct reading (line current) for your vaporizer. All wires should have equal readings +/- 3%. Low current on all wires indicates low input voltage. Drastically different current readings may indicate a defective heater, defective wiring, or an open fusible link due to overheating. If a fusible link is open, contact the factory. Do not attempt to repair. Figure 14 – Full Load Current Check VIEW OF FUSIBLE LINKS IN NORMAL CONDITION FUSIBLE LINKS MEASURE CURRENT COPPER STRIP POWER INPUT WIRING POWER IN VIEW OF FUSIBLE LINKS IN OPEN CONDITION CONTROL BOARD AMP CLAMP ASDI Operations and Maintenance – TX Models – P/N: 52368 6-30 TORREXX Electric Vaporizer Data Sheet MODEL PHASE VOLTAGE (VAC) CURRENT (A) TX25 TX25 TX25 TX25 TX50 TX50 TX50 TX50 TX50 TX50 TX50 TX50 TX100 TX100 TX100 TX100 TX100 TX100 TX100 TX100 TX100 TX100 TX160 TX160 TX160 TX160 TX160 TX160 TX160 TX240 TX240 TX240 TX240 TX320 TX320 TX320 TX320 1 1 1 1 1 3 1 3 1 3 3 3 1 3 1 3 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 120 208 220 240 208 208 220 220 240 240 380 415 208 208 220 220 240 240 380 415 440 480 208 220 240 380 415 440 480 380 415 440 480 380 415 440 480 32.4 14.1 14.9 16.2 28.1 16.3 29.7 17.1 32.4 18.7 9.9 10.8 56.2 32.4 59.5 34.3 54.1 37.4 19.8 21.6 17.1 18.7 49.6 52.4 61.9 30.3 30.0 26.2 26.0 45.4 49.6 39.3 42.9 50.2 54.8 43.4 47.4 6-31 HEATER RESISTANCE (OHMS) 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 14.5 14.5 16.0 14.5 16.0 14.5 16.0 9.7 9.7 9.7 9.7 8.8 8.8 8.8 8.8 WIRE-TO-WIRE RESISTANCE (OHMS) 3.7 14.8 14.8 14.8 7.4 14.8 7.4 14.8 7.4 14.8 44.4 44.4 3.7 7.4 3.7 7.4 4.4 7.4 22.2 22.2 29.6 29.6 4.8 4.8 5.3 14.5 16.0 19.4 21.3 9.7 9.7 12.9 12.9 8.8 8.8 11.7 11.7 POWER (kW) 3.9 2.9 3.3 3.9 5.8 5.8 6.5 6.5 7.8 7.8 6.5 7.8 11.7 11.7 13.1 13.1 13.0 15.6 13.0 15.5 13.1 15.5 17.8 20.0 21.5 19.9 21.5 20.0 21.5 29.8 35.6 29.9 35.6 33.0 39.3 33.1 39.4 ASDI Operations and Maintenance – TX Models – P/N: 52368 Heater Core Resistance NOTE Refer to the Bussing diagram in Appendix A for wire to wire resistance for your vaporizer. CAUTION Turn off electrical power at the disconnect before proceeding. Carefully slide out the control panel for access to the heater wire connections on the contactor. Measure the resistance across each pair of wires. An incorrect resistance reading indicates a faulty heater element, a wiring problem, or an open fusible link. Figure 15 – Heater Core Resistance Wiring Connections READ WIRE TO WIRE RESISTANCE. SEE HEATER WIRING DIAGRAM ASDI Operations and Maintenance – TX Models – P/N: 52368 6-32 Solenoid Valve Leak Test 1) Shut off the outlet hand valve. The inlet hand valve should be open. Start the vaporizer and allow it to heat up until the heaters shutoff. This allows any accumulated liquid in the vaporizer to be forced back toward the supply tank. 2) Disconnect the vaporizer by shutting off the power at the disconnect. Shut off the inlet hand valve. Close the ball valve on the vaporizer pressure gauge and remove the pressure gauge. Cautiously bleed off any LPG pressure in the vaporizer and outlet supply piping. When the pressure reaches no pressure in the vaporizer, reinstall the pressure gauge and verify 0 pressure. 3) Turn on the inlet hand valve. The solenoid valve is closed and you should not have any pressure build up in the vaporizer. If pressure increases, the solenoid valve is leaking and needs to be repaired or replaced. Figure 16 – Solenoid Valve Leak Test Components VAPOR DISCHARGE OUTLET HAND VALVE VAPOR PRESSURE GAUGE FIRST STAGE REGULATOR VAPOR OUT SOLENOID VALVE STRAINER LIQUID INLET HAND VALVE LIQUID IN 6-33 ASDI Operations and Maintenance – TX Models – P/N: 52368 Solenoid Valve Electrical Test NOTE A multimeter is required for the following test. CAUTION Turn off electrical power at the disconnect before performing this procedure. Open the electrical housing at the vaporizer base. Disconnect the 2-PIN Molex plug connector and measure resistance between the pins. You should measure approximately 3 ohms. If not, replace the solenoid coil. Figure 17 – Solenoid Valve Electrical Test RESISTANCE SHOULD BE APPROXIMATELY 3 OHMS 1. DISCONNECT SOLENOID MOLEX FROM MAIN HARNESS 2. MEASURE RESISTANCE 3. RECONNECT WHEN FINISHED ASDI Operations and Maintenance – TX Models – P/N: 52368 6-34 Thermocouple Sensor Replacement CAUTION Always disconnect power to vaporizer before servicing. 1) Shut off power at the disconnect. 2) Remove the control box cover. 3) Disconnect the main power wires attached to the contactor and the wires going to the heaters. 4) Slide the circuit panel half way out of the control box. 5) Disconnect the wire connectors to the control board. 6) The thermocouple can now be removed from the center of the core (see below and Figure 18 and 19) Two types of locking collars have been used on the sensors. Figure 18 – TORREXX Box showing Thermocouple location THERMOCOUPLE WIRES 6-35 ASDI Operations and Maintenance – TX Models – P/N: 52368 FIGURE 19 – Thermocouple Sensor with Bayonet Style Retainer 1) To remove a sensor fitted with the bayonet style retainer, push gently on the retainer while turning to the left. When the retainer is disengaged, pull out the old temperature sensor. 2) Use a short, flat-blade screwdriver to remove the adapter. 3) Install the new spring tab retainer using an appropriately sized open end wrench (1/2” or 13mm) 4) Install the new sensor by applying a small amount of heat transfer grease to the sensor tube and re-inserting in the unit. Squeeze the spring tab while inserting the sensor. Push firmly until the sensor is fully engaged. There should be at least ½” of sheath remaining. 5) Reinstall control board, connect all wires, and reinstall the enclosure cover. Torque cover bolts to 19.5 ft-lb. Check vaporizer operation. ASDI Operations and Maintenance – TX Models – P/N: 52368 6-36 TORREXX OPTIONS 7 Economy Operation The Economy Option minimizes the electric power required to meet your vapor demand by shutting off the outlet of the vaporizer when the natural vaporization rate of the storage tank is able to supply enough vapor to meet the demand. A pressure sensing valve is specially developed to sense the upstream pressure. The valve opens when the tank pressure falls below 30PSIG, and closes at 60PSIG. The pressure sensing valve is a mechanical device and it operates independently to the electrical controls. The Economy Option will NOT function if a pump is used. The pressure set-point of the TORREXX Economy Valve is nonadjustable. Consult ASDI for any custom setpoint. The Economy is normally a factory-installed option. However, a separate Economy valve can be purchased as an add-on in the field. For the Economy Valve field installation kit, use ASDI PN: 41051. Make sure that the Economy Valve is correctly installed. Verify the flow direction on the Rating Plate. Figure 20 – TORREXX Economy valve installation NOTES 1. 2. 3. 4. LIQUID PIPING LOSSES BETWEEN THE VAPORIZER AND THE TANK MUST NOT EXCEED THE HYDROSTATIC HEAD WHEN THE PUMP IS SHUT OFF INSTALL VAPORIZER 1ST STAGE REGULATOR UPSTREAM OF THE TANK VAPOR PRESSSURE CONNECTION POINT. ST SET 1 STAGE VAPORIZER REULATOR 2-4 PSIG HIGHER THAN TANK VAPOR PRESSURE REGULATOR SET-POINT. NO CHECK VALVES IN LIQUID LINE. LIQUID MUST BE ABLE TO FLOW IN BOTH DIRECTIONS *BY OTHERS TANK VAPOR PRESSURE REGULATOR* ISOLATION VALVE* VAPOR BY-PASS LINE OUTLET ISOLATION VALVE* PRESSURE GAUGE* (VAPOR) TO LOAD ASDI ECONOMY VALVE SENSES UPSTREAM PRESSURE (OPEN 30PSIG CLOSED 60PSIG) PRESSURE GAUGE* STORAGE TANK VAPORIZER REGULATOR* STRAINER WITH MAGNET FOR IRON PARTICLE PICK-UP* SEAL OFF REQUIRED* ELECTRIC SERVICE REQUIRED ISOLATION VALVE W/HYDROSTATIC RELIEF* LIQUID ISOLATION VALVE” Note: Economy option cannot be used on an installation that requires a pump. 7-37 ASDI Operations and Maintenance – TX Models – P/N: 52368 TORREXX Economy Valve Maintenance The TORREXX Economy Valve operates by sensing the pressure of the Vaporizer and Storage Tank. The Economy Valve consists of a moving piston which opens and closes the valve’s outlet. The movement of the piston is driven by the pressure force balance between two different sized o-rings and a spring. Follow the instructions below and perform maintenance on the Economy Valve once every two years: Figure 21A – STEP 1 – Unscrew the Inlet Housing from the Outlet Housing. Figure 21B – STEP 2 – Replace the two O-rings (ASDI PN 39013 and 39014). Apply excess lithium o-ring grease. ASDI Operations and Maintenance – TX Models – P/N: 52368 7-38 Figure 21C – STEP 3 – Clean all o-ring contact surfaces and the bottom surface of the Outlet Housing. Apply excess lithium o-ring grease. Figure 21D – STEP 4 – Clean all piston surfaces. Apply excess lithium grease on o-rings. Figure 21E – STEP 5 – Make sure that the Pin Hole is clear and the spring is undamaged. Carefully reassemble all the parts. Apply lubrication grease on the straight threads if necessary.* 7-39 ASDI Operations and Maintenance – TX Models – P/N: 52368 * - The threads between the Inlet Housing and the Outlet Housing are straight threads and are designed to be hand tightened. Gas will NOT leak through these threads because of the seals from the two o-rings. However, the Inlet Housing MUST be screwed all the way down for the Valve to accurately function at the set pressure. Do NOT apply sealing agent or Teflon tape on these threads. Refer to the table below for any replacement parts in the TORREXX Economy Valve. QUANTITY ASDI PART NO. DESCRIPTION 1 1 1 1 1 1 1 2 5001-5023 5001-5025 5001-5024 39013 39014 39018 5001-5026 60204 INLET HOUSING OUTLET HOUSING VALVE PISTON VALVE O-RING (LARGE) VALVE O-RING (SMALL) VALVE SPRING VALVE RATING PLATE RIVET Mercury Relay The life of the vaporizer can be further extended by using a Mercury Relay. Compared to a “dry” contactor, a Mercury Relay reduces the wear and tear each time the heater cycles. A larger explosion-proof enclosure is also used which improves access to the electrical controls. This option is suitable for Class I Division 1 Group D and is only available in the NEC configuration. The Mercury Relay Option can be integrated with all the other TORREXX options (i.e. Economy, Remote, etc.) In addition, customized options such as external lamps/indicators, on/off switches are also available. Please consult ASDI for details. TX Remote Box Please contact ASDI for options available for remote control. ASDI Operations and Maintenance – TX Models – P/N: 52368 7-40 Valve and Strainer Package For TX25 to TX320 ASDI PN: 36922 ¾” NPT inlet, 1” NPT outlet For TX19AA to TX240AA ASDI PN: 36925 Filtaire – Contaminant Separator The Filtaire is a filtering device designed to trap heavy hydrocarbons commonly present in LPG vapor. It also traps other materials, which may be in the gas due to storage conditions and internal condition of the equipment. Impurities are collected in the system and periodically removed through the system blow down drain. Residual heavy end hydrocarbons with boiling points higher than pure LPG are trapped by the filter and fall to the bottom for removal. A complete Filtaire system consists of inlet and outlet connections, a blow-down drain (5), a pressure gauge (4), a vent which is normally plugged (6), and a bypass valve system for cleaning (1, 2, and 3). The bypass valves enable the system to continue operating when the Filtaire is removed for cleaning. FIGURE 22 – Filtaire Operation Leak Test 1. Close outlet valve. 2. Slowly open inlet valve and allow pressure to equalize in the vaporizer. 3. Apply a small amount of soap/water solution to ALL pipe connections. 4. Check for any leaks by observing new bubble formation in the soap/water solution. Repair any leaks before continuing. 7-41 ASDI Operations and Maintenance – TX Models – P/N: 52368 APPENDIX A TECHNICAL INFORMATION ASCO Valve used by Algas-SDI SOLENOID NOISE Solenoid valves emit a sound when operated. When energized, they emit a clicking sound. Also, accompanying the operation of most AC valves, is AC hum. Whether or not AC hum is objectionable actually depends on the requirements and opinion of the user. Normal AC hum is the result of the constantly reversing magnetic field produced by alternating current. The constantly reversing magnetic field can cause vibrations in the solenoid parts. 1. Solenoid noise due to damage solenoid parts such as bent solenoid base assembly, stretched return springs, loose parts, etc. Solution: parts. Inspect valve internals and exterior. Replaced damaged 2. Solenoid noise due to foreign matter between the core and plug-nut. When foreign matter is trapped between the core and plug-nut, the core assembly will rock back and forth at 60 hertz. Eventually, the core and plug-nut face will be distorted, at which time the noise can continue even though the foreign material may have been flushed or removed from the valve. Solution: Replace damaged parts entirely, clean and reassemble. 3. Solenoid noise due to damaged coil. On rare occasions, a severe voltage spike or over voltage can potentially short a small portion of the coil winding. This shorting can cause solenoid noise and coil overheating. However, it would normally lead to rapid coil burnout. The solenoid parts, however, could be damaged enough that the noise would continue even after the coil was replaced due to the deformation produced during the peening process. 4. Missing solenoid parts can severely weaken the magnetic circuit. This can produce a solenoid noise condition. As discussed above, it will probably also result in coil burn-out. Solution: Replace damaged parts, replace lost parts, clean and reassemble. In general, when a noise condition has been encountered, the source of the problem should be determined and eliminated. The valve should then be thoroughly inspected to insure that it is yet repairable. Most times, simple installation of a spare parts kit and a solenoid base sub assembly can restore a valve to like new condition. The restored and reinstalled solenoid valve should be tested to insure proper operation, and a voltage check should be made at the solenoid valve while the valve is energized. In addition, a current reading can be obtained and compared with catalog specifications to verify normal solenoid and coil operation. Note: The coil may have been damaged due to excessive current draw of at damaged shading coil within the solenoid valve. A partial rebuilding of a valve damaged by a noise condition can prove useless as the noise condition would continue. The entire valve should be dismantled and inspected and cleaned. All parts supplied in a spare parts kit should be installed. Further, and additional solenoid parts damaged by a noise condition such as a solenoid base sub assembly, should be replaced. Examine valve seating, pistons and the valve body to verify that they have not been damaged. Damage to major portions of the valve may make repairing the valve uneconomical. Should a noise condition be encountered, immediate action may prevent any damage to the solenoid valve itself. TORREXX Vertical Electric Vaporizer Data Sheet LPG Systems Refer to Nameplate on unit for the model and voltage information then look up specific information on the tables below. General Specifications: Applies to all units Electrical: 50 – 60 Hz, NEMA 4, 1 Phase units are 2 wire, 3 Phase units are 3 wire Starting Temperature: 54 Deg. C 130 Deg. F Operating Temperature: 71-79 Deg. C 160-175 Deg. F High Temperature Limit: 171 Deg. C 340 Deg. F Connections: ¾” FNPT – Inlet; 1” FNPT – Outlet Conduits: 1” FNPT, Conduit Seal-Off by others Type of Service: Propane Vaporization ASME Pressure Vessel: 250 PSIG MAWP Heat Exchanger Area: 2.9 ft2 / 0.269 m2 Dry Weight: TX25, TX50 and TX100 4.3 ft2 / 0.399 m2 TX160 5.4 ft2 / 0.503 m2 TX240 7.1 ft2 / 0.660 m2 TX320 128 lbs / 58.1 kg TX25, TX50 and TX100 145 lbs* / 65.8 kg* TX160 155 lbs* / 70.3 kg* TX240 173 lbs* / 78.5 kg* TX320 * - Add 50 lbs / 22.7 kg if vaporizer if the Mercury Relay option is installed. Wiring: Meets NFPA Pamphlet 70 requirements for Class I Division 1 Group D Other: Meets NFPA Pamphlet 58 requirements for electric vaporizers and may be installed per indirect fired vaporizers limitations. C “TORREXX” is a trademark of Algas-SDI International LLC. TORREXX VERTICAL ELECTRIC VAPORIZER DATA SHEET FOR LPG SYSTEMS Table: LPG VAPORIZER DATA TABLE MODEL PHASE VOLTAGE CURRENT Amps. POWER kW TX-25 TX-25 TX-25 TX-25 TX-50 TX-50 TX-50 TX100 TX100 TX100 TX-50 TX-50 TX-50 TX-50 TX-50 TX-50 TX100 TX100 TX100 TX100 TX100 TX100 TX100 TX100 TX160 TX160 TX160 TX160 TX160 TX160 TX160 TX160 TX240 TX240 TX240 TX240 TX240 TX320 TX320 TX320 TX320 TX320 TX320 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 120 208 220 240 208 220 240 208 220 240 208 220 240 380 400 415 208 220 240 380 400 415 440 480 208 220 240 380 400 415 440 480 380 400 415 440 480 380 400 415 440 480 575 32.4 14.1 14.9 16.2 28.1 29.7 32.4 56.2 59.5 54.1 16.2 17.1 18.7 9.9 10.4 10.8 32.4 34.3 37.4 19.8 20.8 21.6 17.1 18.7 49.6 52.4 51.9 30.3 28.9 30.0 26.2 26.0 45.4 47.8 49.6 39.3 42.9 33.0 36.6 39.3 33.1 39.4 39.2 4 3 3 3 6 7 8 12 13 13 6 7 8 7 7 8 12 13 16 13 14 16 13 16 18 20 22 20 20 22 20 22 30 33 36 30 36 33 37 39 33 39 39 EQUIPMENT DRAWING 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 5001 - 6001 ELECTRICAL DRAWING 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 BUSSING DIAGRAM 0620 - 7007 0620 - 7003 0620 - 7003 0620 - 7003 0620 - 7004 0620 - 7004 0620 - 7004 0620 - 7007 0620 - 7007 0620 - 7008 0620 - 7005 0620 - 7005 0620 - 7005 0620 - 7028 0620 - 7028 0620 - 7028 0620 - 7009 0620 - 7009 0620 - 7009 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7009 0620 - 7009 0620 - 7012 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7010 TORREXX Electric Vaporizer Spare Parts and Accessories REFERENCE KEY SPARE PARTS TX25 120V 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID 10 11 12 13 14 15 16 17 18 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40421 40421 40421 40421 40421 REFERENCE KEY SPARE PARTS 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID TX100 380V 400V 415V 53890 52607-01 53630 TX100 440V 480V 575V 53890 52608-01 53630 TX160 208V 220V 240V 53890 52606-01 53630 TX160 380V 400V 415V 53890 52607-01 53630 TX160 440V 480V 575V 53890 52608-01 53630 5001-4009-01 5001-4009-01 5001-4009-02 5001-4009-02 5001-4009-02 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 10 11 12 13 14 15 16 17 18 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40421 40421 40421 40421 40421 53890 52605-01 53630 TX25 208V 220V 240V 53890 52606-01 53630 TX50 208V 220V 240V 53890 52606-01 53630 TX50 380V 400V 415V 53890 52607-01 53630 TX100 208V 220V 240V 53890 52606-01 53630 5001-4009-01 5001-4009-01 5001-4009-01 5001-4009-01 5001-4009-01 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 REFERENCE KEY SPARE PARTS 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID 10 11 12 13 14 15 16 17 18 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40421 40421 40421 40421 TX240 380V 400V 415V 53890 52607-01 53630 TX240 440V 480V 575V 53890 52608-01 53630 TX320 380V 400V 415V 53890 52607-01 53630 TX320 440V 480V 575V 53890 52608-01 53630 5001-4009-03 5001-4009-03 5001-4009-04 5001-4009-04 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 FIGURE 23 – TORREXX electric vaporizer major components and accessories 8 7 5 6 4 19 3 2 1 18 TORREXX Vertical Electric Vaporizer Data Sheet Ammonia Systems Refer to Nameplate on unit for the model and voltage information then look up specific information on the tables below. General Specifications: Applies to all units Electrical: 50 – 60 Hz, NEMA 4, 1 Phase units are 2 wire, 3 Phase units are 3 wire Starting Temperature: 54 Deg. C 130 Deg. F Operating Temperature: 90 Deg. C 195 Deg. F High Temperature Limit: 171 Deg. C 340 Deg. F Connections: ¾” NPT 300# Flanged SST Inlet; 1” NPT 300# Flanged SST Outlet Conduits: 1” FNPT, Conduit Seal-Off by others Type of Service: Ammonia Vaporization ASME Pressure Vessel: 250 PSIG MAWP Heat Exchanger Area: 2.9 ft2 / 0.269 m2 Dry Weight: TX19AA, TX38AA and TX75AA 4.3 ft2 / 0.399 m2 TX120AA 5.4 ft2 / 0.503 m2 TX180AA 7.1 ft2 / 0.660 m2 TX240AA 128 lbs / 58.1 kg TX19AA, TX38AA and TX75AA 145 lbs* / 65.8 kg* TX120AA 155 lbs* / 70.3 kg* TX180AA 173 lbs* / 78.5 kg* TX240AA * - Add 50 lbs / 22.7 kg if vaporizer if the Mercury Relay option is installed. Wiring: Meets NFPA Pamphlet 70 requirements for Class I Division 1 Group D Other: Meets NFPA Pamphlet 58 requirements for electric vaporizers and may be installed per indirect fired vaporizer limitations. “TORREXX” is a trademark of Algas-SDI International LLC. TORREXX VERTICAL ELECTRIC VAPORIZER DATA SHEET FOR AMMONIA SYSTEMS Table: AMMONIA VAPORIZER DATA TABLE MODEL PHASE VOLTAGE CURRENT Amps. POWER kW TX-19AA TX-19AA TX-19AA TX-19AA TX-38AA TX-38AA TX-38AA TX-75AA TX-75AA TX-75AA TX-38AA TX-38AA TX-38AA TX-38AA TX-38AA TX-38AA TX-75AA TX-75AA TX-75AA TX-75AA TX-75AA TX-75AA TX-75AA TX-75AA TX120AA TX120AA TX120AA TX120AA TX120AA TX120AA TX120AA TX120AA TX180AA TX180AA TX180AA TX180AA TX180AA TX240AA TX240AA TX240AA TX240AA TX240AA TX240AA 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 120 208 220 240 208 220 240 208 220 240 208 220 240 380 400 415 208 220 240 380 400 415 440 480 208 220 240 380 400 415 440 480 380 400 415 440 480 380 400 415 440 480 575 32.4 14.1 14.9 16.2 28.1 29.7 32.4 56.2 59.5 54.1 16.2 17.1 18.7 9.9 10.4 10.8 32.4 34.3 37.4 19.8 20.8 21.6 17.1 18.7 49.6 52.4 51.9 30.3 28.9 30.0 26.2 26.0 45.4 47.8 49.6 39.3 42.9 33.0 36.6 39.3 33.1 39.4 39.2 4 3 3 3 6 7 8 12 13 13 6 7 8 7 7 8 12 13 16 13 14 16 13 16 18 20 22 20 20 22 20 22 30 33 36 30 36 33 37 39 33 39 39 EQUIPMENT DRAWING 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 5001 - 6002 ELECTRICAL DRAWING 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 BUSSING DIAGRAM 0620 - 7007 0620 - 7003 0620 - 7003 0620 - 7003 0620 - 7004 0620 - 7004 0620 - 7004 0620 - 7007 0620 - 7007 0620 - 7008 0620 - 7005 0620 - 7005 0620 - 7005 0620 - 7028 0620 - 7028 0620 - 7028 0620 - 7009 0620 - 7009 0620 - 7009 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7009 0620 - 7009 0620 - 7012 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7011 0620 - 7011 0620 - 7010 TORREXX Electric Vaporizer Spare Parts and Accessories (Ammonia) REFERENCE KEY SPARE PARTS TX19AA TX19AA TX38AA TX38AA TX75AA 120V 208V 208V 380V 208V 220V 220V 400V 220V 240V 240V 415V 240V 1 TEMPERATURE CONTROL BOARD 53890 53890 53890 53890 53890 2 3 TRANSFORMER CONTACTOR 52605-01 53630 52606-01 53630 52606-01 53630 52607-01 53630 52606-01 53630 4 THERMOCOUPLE 5001-4009-01 5001-4009-01 5001-4009-01 5001-4009-01 5001-4009-01 5 Liqui-SAFE VALVE 5001-3004 5001-3004 5001-3004 5001-3004 5001-3004 6 PRESSURE RELIEF VALVE 30749 30749 30749 30749 30749 35379 7 RAIN CAP 35379 35379 35379 35379 8 FUSIBLE LINK 33139 33139 33139 33139 33139 9 INLET SOLENOID 36111 36111 36111 36111 36111 10 FUSE KIT 52222 52222 52222 52222 52222 11 ECONOMY VALVE FIELD INSTALL KIT 41053 41053 41053 41053 41053 12 MERCURY RELAY CONTACTOR 53325 53325 53325 53325 53325 13 TRANSFORMER (MERCURY RELAY) TBD TBD TBD TBD TBD 14 WIRE HARNESS (MERCURY RELAY) 5001-5033 5001-5033 5001-5033 5001-5033 5001-5033 15 PIPE AWAY ADAPTOR 30967 30967 30967 30967 30967 16 VALVE, GAUGE AND STRAINER KIT 36925 36925 36925 36925 36925 17 STAND 20437 20437 20437 20437 20437 18 WIRE HARNESS (MAIN) 53820 53820 53820 53820 53820 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40422 40422 40422 40422 40422 REFERENCE KEY SPARE PARTS 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID TX75AA 380V 400V 415V 53890 52607-01 53630 TX75AA 440V 480V 575V 53890 52608-01 53630 TX120AA 208V 220V 240V 53890 52606-01 53630 TX120AA 380V 400V 415V 53890 52607-01 53630 TX120AA 440V 480V 575V 53890 52608-01 53630 5001-4009-01 5001-4009-01 5001-4009-02 5001-4009-02 5001-4009-02 5001-3004 30749 35379 33139 36111 5001-3004 30749 35379 33139 36111 5001-3004 30749 35379 33139 36111 5001-3004 30749 35379 33139 36111 5001-3004 30749 35379 33139 36111 10 11 12 13 14 15 16 17 18 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 52222 41053 53325 TBD 5001-5033 30967 36925 20437 53820 52222 41053 53325 TBD 5001-5033 30967 36925 20437 53820 52222 41053 53325 TBD 5001-5033 30967 36925 20437 53820 52222 41053 53325 TBD 5001-5033 30967 36925 20437 53820 52222 41053 53325 TBD 5001-5033 30967 36925 20437 53820 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40422 40422 40422 40422 40422 REFERENCE KEY SPARE PARTS TX150AA TX150AA TX200AA TX200AA 380V 440V 380V 440V 400V 480V 400V 480V 415V 575V 415V 575V 1 TEMPERATURE CONTROL BOARD 53890 53890 53890 53890 2 TRANSFORMER 52607-01 52608-01 52607-01 52608-01 3 CONTACTOR 53630 53630 53630 53630 4 THERMOCOUPLE 5001-4009-03 5001-4009-03 5001-4009-04 5001-4009-04 5 Liqui-SAFE VALVE 5001-3004 5001-3004 5001-3004 5001-3004 6 PRESSURE RELIEF VALVE 30749 30749 30749 30749 7 RAIN CAP 35379 35379 35379 35379 8 FUSIBLE LINK 33139 33139 33139 33139 9 INLET SOLENOID 36111 36111 36111 36111 10 FUSE KIT 52222 52222 52222 52222 11 ECONOMY VALVE FIELD INSTALL KIT 41053 41053 41053 41053 12 MERCURY RELAY CONTACTOR 53325 53325 53325 53325 13 TRANSFORMER (MERCURY RELAY) TBD TBD TBD TBD 14 WIRE HARNESS (MERCURY RELAY) 5001-5033 5001-5033 5001-5033 5001-5033 15 PIPE AWAY ADAPTOR 30967 30967 30967 30967 16 VALVE, GAUGE AND STRAINER KIT 36925 36925 36925 36925 17 STAND 20437 20437 20437 20437 18 WIRE HARNESS (MAIN) 53820 53820 53820 53820 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40422 40422 40422 40422 TORREXX Vertical Electric Vaporizer Data Sheet NEMKO LPG Systems Refer to Nameplate on unit for the model and voltage information then look up specific information on the tables below. General Specifications: Applies to all units Electrical: 50 – 60 Hz, NEMA 4, 1 Phase units are 2 wire, 3 Phase units are 3 wire Starting Temperature: 54 Deg. C 130 Deg. F Operating Temperature: 71-79 Deg. C 160-175 Deg. F High Temperature Limit: 171 Deg. C 340 Deg. F Connections: ¾” FNPT – Inlet; 1” FNPT – Outlet Conduits: 1” FNPT, Conduit Seal-Off by others Type of Service: Propane Vaporization ASME Pressure Vessel: 250 PSIG MAWP Heat Exchanger Area: 2.9 ft2 / 0.269 m2 Dry Weight: TX25, TX50 and TX100 4.3 ft2 / 0.399 m2 TX160 5.4 ft2 / 0.503 m2 TX240 7.1 ft2 / 0.660 m2 TX320 128 lbs / 58.1 kg TX25, TX50 and TX100 145 lbs / 65.8 kg TX160 155 lbs / 70.3 kg TX240 173 lbs / 78.5 kg TX320 Hazardous Area Rating: NEMKO 04 ATEX 1026X EEx d IIB T3 TO AVOID POTENTIAL ELECTROSTATIC CHARGING HAZARD, ALWAYS USE A DAMP CLOTH FOR CLEANING THE INSULATION JACKET. AVOID DRY RUBBING OF THE INSULATION JACKET. “TORREXX” is a trademark of Algas-SDI International LLC. TORREXX VERTICAL ELECTRIC VAPORIZER DATA SHEET FOR LPG SYSTEMS (NEMKO) Table: NEMKO LPG VAPORIZER DATA TABLE MODEL PHASE VOLTAGE CURRENT Amps. POWER kW TX-25 TX-25 TX-50 TX-50 TX100 TX100 TX-50 TX-50 TX-50 TX-50 TX-50 TX100 TX100 TX100 TX100 TX100 TX160 TX160 TX160 TX160 TX160 TX240 TX240 TX240 TX320 TX320 TX320 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 220 240 220 240 220 240 220 240 380 400 415 220 240 380 400 415 220 240 380 400 415 380 400 415 380 400 415 14.9 16.2 29.7 32.4 59.5 54.1 17.1 18.7 9.9 10.4 10.8 34.3 37.4 19.8 20.8 21.6 52.4 51.9 30.3 28.9 30.0 45.4 47.8 49.6 33.0 36.6 39.3 3 3 7 8 13 13 7 8 7 7 8 13 16 13 14 16 20 22 20 20 22 30 33 36 33 37 39 EQUIPMENT DRAWING 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 5001 - 6003 ELECTRICAL DRAWING 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 5001-7008 BUSSING DIAGRAM 0620 - 7003 0620 - 7003 0620 - 7004 0620 - 7004 0620 - 7007 0620 - 7008 0620 - 7005 0620 - 7005 0620 - 7028 0620 - 7028 0620 - 7028 0620 - 7009 0620 - 7009 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7009 0620 - 7012 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 TORREXX Electric Vaporizer Spare Parts and Accessories (NEMKO) REFERENCE KEY SPARE PARTS TX25 120V 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID 10 11 12 13 14 15 16 17 18 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40421 40421 40421 40421 40421 REFERENCE KEY SPARE PARTS 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID TX100 380V 400V 415V 53890 52607-01 53630 TX100 440V 480V 575V 53890 52608-01 53630 TX160 208V 220V 240V 53890 52606-01 53630 TX160 380V 400V 415V 53890 52607-01 53630 TX160 440V 480V 575V 53890 52608-01 53630 5001-4009-01 5001-4009-01 5001-4009-02 5001-4009-02 5001-4009-02 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 8 10 11 12 13 14 15 16 17 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 18 CORROSION INHIBITING TAPE 60806 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40421 40421 40421 40421 40421 53890 52605-01 53630 TX25 208V 220V 240V 53890 52606-01 53630 TX50 208V 220V 240V 53890 52606-01 53630 TX50 380V 400V 415V 53890 52607-01 53630 TX100 208V 220V 240V 53890 52606-01 53630 5001-4009-01 5001-4009-01 5001-4009-01 5001-4009-01 5001-4009-01 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 REFERENCE KEY SPARE PARTS 1 2 3 4 5 6 7 8 9 TEMPERATURE CONTROL BOARD TRANSFORMER CONTACTOR THERMOCOUPLE Liqui-SAFE VALVE PRESSURE RELIEF VALVE RAIN CAP FUSIBLE LINK INLET SOLENOID 10 11 12 13 14 15 16 17 18 FUSE KIT ECONOMY VALVE FIELD INSTALL KIT MERCURY RELAY CONTACTOR TRANSFORMER (MERCURY RELAY) WIRE HARNESS (MERCURY RELAY) PIPE AWAY ADAPTOR VALVE, GAUGE AND STRAINER KIT STAND WIRE HARNESS (MAIN) 19 CORROSION INHIBITING TAPE 60806 60806 60806 60806 20 INLET SOLENOID KIT 40287 40287 40287 40287 21 Liqui-SAFE VALVE O-RING KIT 40421 40421 40421 40421 TX240 380V 400V 415V 53890 52607-01 53630 TX240 440V 480V 575V 53890 52608-01 53630 TX320 380V 400V 415V 53890 52607-01 53630 TX320 440V 480V 575V 53890 52608-01 53630 5001-4009-03 5001-4009-03 5001-4009-04 5001-4009-04 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 5001-3003 35009 35379 33139 36111 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 52222 41051 53325 TBD 5001-5033 30752 36922 20437 53820 TORREXX Vertical Electric Vaporizer Data Sheet Ammonia Systems (NEMKO) Refer to Nameplate on unit for the model and voltage information then look up specific information on the tables below. General Specifications: Applies to all units Electrical: 50 – 60 Hz, NEMA 4, 1 Phase units are 2 wire, 3 Phase units are 3 wire Starting Temperature: 54 Deg. C 130 Deg. F Operating Temperature: 90 Deg. C 195 Deg. F High Temperature Limit: 171 Deg. C 340 Deg. F Connections: ¾” NPT 300# Flanged SST Inlet; 1” NPT 300# Flanged SST Outlet Conduits: 1” FNPT, Conduit Seal-Off by others Type of Service: Ammonia Vaporization ASME Pressure Vessel: 250 PSIG MAWP Heat Exchanger Area: 2.9 ft2 / 0.269 m2 Dry Weight: TX19AA, TX38AA and TX75AA 4.3 ft2 / 0.399 m2 TX120AA 5.4 ft2 / 0.503 m2 TX180AA 7.1 ft2 / 0.660 m2 TX240AA 128 lbs / 58.1 kg TX19AA, TX38AA and TX75AA 145 lbs / 65.8 kg TX120AA 155 lbs / 70.3 kg TX180AA 173 lbs / 78.5 kg TX240AA Hazardous Area Rating: NEMKO 04 ATEX 1026X EEx d IIB T3 TO AVOID POTENTIAL ELECTROSTATIC CHARGING HAZARD, ALWAYS USE A DAMP CLOTH FOR CLEANING THE INSULATION JACKET. AVOID DRY RUBBING OF THE INSULATION JACKET. “TORREXX” is a trademark of Algas-SDI International LLC. TORREXX VERTICAL ELECTRIC VAPORIZER DATA SHEET FOR AMMONIA SYSTEMS (NEMKO) Table: NEMKO AMMONIA VAPORIZER DATA TABLE EQUIPMENT CURRENT POWER MODEL PHASE VOLTAGE Amps. kW DRAWING 1 220 14.9 3 5001 - 6004 TX-19AA 1 240 16.2 3 5001 - 6004 TX-19AA 1 220 29.7 7 5001 - 6004 TX-38AA 1 240 32.4 8 5001 - 6004 TX-38AA 1 220 59.5 13 5001 - 6004 TX-75AA 1 240 54.1 13 5001 - 6004 TX-75AA 3 220 17.1 7 5001 - 6004 TX-38AA 3 240 18.7 8 5001 - 6004 TX-38AA 3 380 9.9 7 5001 - 6004 TX-38AA 3 400 10.4 7 5001 - 6004 TX-38AA 3 415 10.8 8 5001 - 6004 TX-38AA 3 220 34.3 13 5001 - 6004 TX-75AA 3 240 37.4 16 5001 - 6004 TX-75AA 3 380 19.8 13 5001 - 6004 TX-75AA 3 400 20.8 14 5001 - 6004 TX-75AA 3 415 21.6 16 5001 - 6004 TX-75AA 3 220 52.4 20 5001 - 6004 TX120AA 3 240 51.9 22 5001 - 6004 TX120AA 3 380 30.3 20 5001 - 6004 TX120AA 3 400 28.9 20 5001 - 6004 TX120AA 3 415 30.0 22 5001 - 6004 TX120AA 3 380 45.4 30 5001 - 6004 TX180AA 3 400 47.8 33 5001 - 6004 TX180AA 3 415 49.6 36 5001 - 6004 TX180AA 3 380 33.0 33 5001 - 6004 TX240AA 3 400 36.6 37 5001 - 6004 TX240AA 3 415 39.3 39 5001 - 6004 TX240AA ELECTRICAL DRAWING 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 5001 - 7008 BUSSING DIAGRAM 0620 - 7003 0620 - 7003 0620 - 7004 0620 - 7004 0620 - 7007 0620 - 7008 0620 - 7005 0620 - 7005 0620 - 7028 0620 - 7028 0620 - 7028 0620 - 7009 0620 - 7009 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7009 0620 - 7012 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 0620 - 7010 ...Innovative liquid vaporizing and gas mixing solutions EC Declaration of Conformity WE, Algas-SDI 151 South Michigan Seattle, WA 98108 USA Declare, solely under own responsibility, that the product Model: TX Series, LPG vaporizer for converting liquefied petroleum to vapor by means of an electric heater/heat exchanger. Mentioned in this declaration, complies with the following standards and/or normative documents: Requirements Remarks Certificates No. 94/9/EC, Annex VII Product Quality Assurance ATEX Directive DNV-2006-OSL-ATEX-0166Q Notified Body: Det Norske Veritas AS Veritasveien 1 N-1322 Hovik, Norway 0575 CE NEMKO 04ATEX1026X EN 50014: June 1997 February 1999 February 1999 EN 50018: November 2000 September 2002 II 2 G EEx d IIB T3 Electrical Apparatus for Potentially Explosive Atmospheres – General Requirements Amendment 1 Amendment 2 Electrical Apparatus for Explosive Gas Atmospheres – Flame proof Enclosures “d” Amendment 1 Type Examination Body: NEMKO P.O. Box 73 Blindern N-0314 OSLO, Norway 0470 97/23/EC Pressure Equipment Directive Module H PED-H-40065-2008-CE-USA-NA Technical Standards Applied: ASME B&PV Code, Section VIII, Div. 1 Notified Body: Det Norske Veritas AS Veritasveien 1 N-1322 Hovik, Norway 0575 1 of 2 ...Innovative liquid vaporizing and gas mixing solutions CE Declaration of Conformity Continued: Requirements Remarks Certificates No. 89/336/EEC EMC Directive ETL/017/1998 EN 50082-2 Electromagnetic Compatibility – Generic Immunity Standard, Part 2. Industrial Environment Electrostatic Discharge Radiated Electromagnetic Field Radiated Electromagnetic Field from Digital Radio Telephones Electrical Fast Transient/Burst Conducted Disturbances Induced By RadioFrequency Fields Power Frequency Magnetic Field Immunity EN 61000-4-2 ENV 50140 ENV 50204 EN 61000-4-4 ENV 50141 EN 61000-4-8 Conformity Assessment: Quest Engineering Solutions 7 Sterling Road, PO Box 125 N. Billerica, MA 01862 US0030 _________________________ Mike Zimmer, PE Director of Engineering May 15, 2009 2 of 2 Installation & Maintenance Instructions SERIES 8003G 8202G OPEN-FRAME, GENERAL PURPOSE, WATERTIGHT/EXPLOSIONPROOF SOLENOIDS INSTALLATION Ċ SERVICE NOTICE Ċ ASCO solenoid valves with design change letter G" or H" in the catalog number (ex. 8210G 1) have an epoxy encapsulated ASCO Red Hat II solenoid. This solenoid replaces some of the solenoids with metal enclosures and open-frame constructions. Follow these installation and maintenance instructions if your valve or operator uses this solenoid. See separate instructions for basic valve. Check nameplate for correct catalog number, service, and wattage. Check front of solenoid for voltage and frequency. WARNING: Electrical hazard from the accessibility of live parts. To prevent the possibility of death,Ăserious injury or property damage, install the open - frame solenoid in an enclosure. FOR BLACK ENCLOSURE TYPES 7 AND 9 ONLY DESCRIPTION Catalog numbers 8003G and 8202G are epoxy encapsulated pull-type solenoids. The green solenoid with lead wires and 1/2Ăconduit connection is designed to meet Enclosure Type 1-General Purpose, Type 2-Dripproof, Types 3 and 3S-Raintight, and Types 4 and 4X-Watertight. The black solenoid on catalog numbers prefixed EF" or EV" is designed to meet Enclosure Types 3 and 3S-Raintight, Types 4 and 4X-Watertight, Types 6 and 6P-Submersible, Type 7 (A, B, C & D) Explosionproof Class I, Division 1 Groups A, B, C, & D and Type 9 (E, F, & G)-Dust-Ignitionproof Class II, Division 1 Groups E, F & G. The Class II, Groups F & G Dust Locations designation is not applicable for solenoids or solenoid valves used for steam service or when a class H" solenoid is used. See Temperature Limitations section for solenoid identification and nameplate/retainer for service. When installed just as a solenoid and not attached to an ASCO valve, the core has a 0.250-28 UNF-2B tapped hole, 0.38 or 0.63 minimum full thread. NOTE: Catalog number prefix EV" denotes stainless steel construction. Catalog numbers 8202G1, 8202G3, 8202G5 and 8202G7 are epoxy encapsulated push-type, reverse-acting solenoids having the same enclosure types as previously stated for Catalog numbers 8003G1 and 8003G2. Series 8003G and 8202G solenoids are available in: Open-Frame Construction: The green solenoid may be supplied with 1/4 spade, screw or DIN terminals. (Refer to Figure 4) Panel Mounted Construction: These solenoids are specifically designed to be panel mounted by the customer through a panel having a .062 to .093 maximum wall thickness. Refer to Figure 1 and section on Installation of Panel Mounted Solenoid. Optional Features For Type 1 - General Purpose Construction Only Junction Box: This junction box construction meets Enclosure Types 2,3,3S,4, and 4X. Only solenoids with 1/4 spade or screw terminals may have a junction box. The junction box provides a 1/2 conduit connection, grounding and spade or screw terminal connections within the junction box (See Figure 5). DIN Plug Connector Kit No.K236034:Ă Use this kit only for solenoids with DIN terminals. The DIN plug connector kit provides a two pole with grounding contact DIN Type 43650 construction (See Figure 6). OPERATION Series 8003G - When the solenoid is energized, the core is drawn into the solenoid base sub-assembly. IMPORTANT: When the solenoid is de-energized, the initial return force for the core, whether developed by spring, pressure, or weight, must exert a minimum force to overcome residual magnetism created by the solenoid. Minimum return force for AC construction is 11 ounces, and 5 ounces for DC construction. Series 8202G - When the solenoid is energized, the disc holder assembly seats against the orifice. When the solenoid is de-energized , the disc holder assembly returns. IMPORTANT: Initial return force for the disc or disc holder assembly, whether developed by spring, pressure, or weight, must exert a minimum force to overcome residual magnetism created by the solenoid. Minimum return force is 1 pound, 5 ounces. MM Form No.V6584R8 All Rights Reserved. 50 Hanover Road, Florham Park, New Jersey 07932 CAUTION: To prevent fire or explosion, do not install solenoid and/or valve where ignition temperature of hazardous atmosphere is less than 165 C. On valves used for steam service or when a class H" solenoid is used, do not install in hazardous atmosphere where ignition temperature is less than 180C. See nameplate/retainer for service. NOTE: These solenoids have an internal non-resetable thermal fuse to limit solenoid temperature in the event that extraordinary conditions occur which could cause excessive temperatures. These conditions include high input voltage, a jammed core, excessive ambient temperature or a shorted solenoid, etc. This unique feature is a standard feature only in solenoids with black explosionproof/dust-ignitionproof enclosures (Types 7 & 9). CAUTION: To protect the solenoid valve or operator, install a strainer or filter, suitable for the service involved in the inlet side as close to the valve or operator as possible. Clean periodically depending on service conditions. See ASCO Series 8600, 8601, and 8602 for strainers. Temperature Limitations For maximum valve ambient temperatures, refer to chart. The temperature limitations listed, only indicate maximum application temperatures for field wiring rated at 90C. Check catalog number prefix and watt rating on nameplate to determine maximum ambient temperature. See valve installation and maintenance instructions for maximum fluid temperature. NOTE: For steam service, refer to Wiring section, Junction Box for temperature rating of supply wires. Temperature Limitations For Series 8003G or 8202G Solenoids for use on Valves Rated at 10.1, 11.6, 17.1, or 22.6 Watts Watt Rating Catalog Number Coil Prefix Class of Insulation Maximum Ambient Temp. 10.1 & 17.1 None, FB, KF, KP SC, SD, SF, & SP, F 125F (51.7C) 10.1 & 17.1 HB, HT, KB, KH, SS, ST, SU, H 140F (60C) 11.6 & 22.6 None, FB,KF, KP, SC, SD, SF, & SP. F 104F (40C) 11.6 & 22.6 HP, HT, KB, KH, SS, ST, SU, & SV H 104F (40C) Minimum ambient temperature -40 F (-40 C). Positioning This solenoid is designed to perform properly when mounted in any position. However, for optimum life and performance, the solenoid should be mounted vertically and upright to reduce the possibility of foreign matter accumulating in the solenoid base sub-assembly area. Wiring Wiring must comply with local codes and the National Electrical Code. All solenoids supplied with lead wires are provided with a grounding wire which is green or green with yellow stripes and a 1/2 conduit connection. To Printed in U.S.A. www.ascovalve.com Page 1 of 4 facilitate wiring, the solenoid may be rotated 360. For the watertight and explosionproof solenoid, electrical fittings must be approved for use in the approved hazardous locations. CAUTION: Cryogenic Applications - Solenoid lead wire insulation should not be subjected to cryogenic temperatures. Adequate lead wire protection and routing must be provided. Additional Wiring Instructions For Optional Features: Open-Frame solenoid with 1/4 spade terminals. For solenoids supplied with screw terminal connections use #12-18 AWG stranded copper wire rated at 90C or greater. Torque terminal block screws to 10 ± 2 in-lbs [1,0 ± 1,2 Nm]. A tapped hole is provided in the solenoid for grounding, use a #10-32 machine screw. Torque grounding screw to 15 - 20 in-lbs [1,7 - 2,3 Nm]. On solenoids with screw terminals, the socket head screw holding the terminal block to the solenoid is the grounding screw. Torque the screw to 15 - 20 in-lbs [1,7 - 2,3 Nm] with a 5/32 hex key wrench. Junction Box The junction box is used with spade or screw terminal solenoids only and is provided with a grounding screw and a 1/2 conduit connection. Connect #12-18 AWG standard copper wire only to the screw terminals. Within the junction box use field wire that is rated 90C or greater for connections. For steam service use 105C rated wire up to 50 psi or use 125C rated wire above 50 psi. After electrical hookup, replace cover gasket, cover, and screws. Tighten screws evenly in a crisscross manner. DIN Plug Connector Kit No.K236034 1. The open-frame solenoid is provided with DIN terminals to accommodate the plug connector kit. 2. Remove center screw from plug connector. Using a small screwdriver, pry terminal block from connector cover. 3. Use #12-18 AWG stranded copper wire rated at 90C or greater for connections. Strip wire leads back approximately 1/4 for installation in socket terminals. The use of wire-end sleeves is also recommended for these socket terminals. Maximum length of wire-end sleeves to be approximately 1/4.ĂTinning of the ends of the lead wires is not recommended. 4. Thread wire through gland nut, gland gasket, washer and connector cover. NOTE: Connector housing may be rotated in 90 increments from position shown for alternate positioning of cable entry. 5. Check DIN connector terminal block for electrical markings. Then make electrical hookup to terminal block according to markings on it. Snap terminal block into connector cover and install center screw. 6. Position connector gasket on solenoid and install plug connector. Torque center screw to 5 ± 1 in-lbs [0,6 ± 1,1 Nm]. NOTE: Alternating current (AC) and direct current (DC) solenoids are built differently. To convert from one to the other, it may be necessary to change the complete solenoid including the core and solenoid base sub-assembly, not just the solenoid. Consult ASCO. Installation of Solenoid Solenoids may be assembled as a complete unit. Tightening is accomplished by means of a hex flange at the base of the solenoid. Installation of Panel Mounted Solenoid (See Figure 1) 1. Disassemble solenoid following instruction under Solenoid Replacement then proceed. 2. Install solenoid base sub-assembly through customer panel. 3. Position spring washer on opposite side of panel over solenoid base sub-assembly. 4. Replace solenoid, nameplate/retainer and red cap. 5. Make electrical hookup, see Wiring section. Solenoid Temperature Standard solenoids are designed for continuous duty service. When the solenoid is energized for a long period, the solenoid becomes hot and can be touched by hand only for an instant. This is a safe operating temperature. MAINTENANCE WARNING: To prevent the possibility of death, serious injury or property damage, turn off electrical power, depressurize solenoid operator and/or valve, and vent fluid to a safe area before servicing. Cleaning All solenoid operators and valves should be cleaned periodically. The time between cleaning will vary depending on medium and service conditions. In general, if the voltage to the solenoid is correct, sluggish valve operation, excessive noise or leakage will indicate that cleaning is required. Clean strainer or filter when cleaning the valve. Preventive Maintenance Keep the medium flowing through the solenoid operator or valve as free from dirt and foreign material as possible. While in service, the solenoid operator or valve should be operated at least once a month to insure proper opening and closing. Depending on the medium and service conditions, periodic inspection of internal valve parts for damage or excessive wear is recommended. Thoroughly clean all parts. Replace any worn or damaged parts. Causes of Improper Operation Faulty Control Circuit: Check the electrical system by energizing the solenoid. A metallic click signifies that the solenoid is operating. Absence of the click indicates loss of power supply. Check for loose or blown fuses, open-circuited or grounded solenoid, broken lead wires or splice connections. Burned-Out Solenoid: Check for open-circuited solenoid. Replace if necessary. Check supply voltage; it must be the same as specified on nameplate/retainer and marked on the solenoid. Check ambient temperature and check that the core is not jammed. Low Voltage: Check voltage across the solenoid leads. Voltage must be at least 85% of rated voltage. Solenoid Replacement 1. Disconnect conduit, coil leads, and grounding wire. NOTE: Any optional parts attached to the old solenoid must be reinstalled on the new solenoid. For 3-way construction, piping or tubing must be removed from pipe adapter. 2. Disassemble solenoids with optional features as follows: Spade or Screw Terminals Remove terminal connections, grounding screw, grounding wire, and terminal block (screw terminal type only). NOTE: For screw terminals, the socket head screw holding the terminal block serves as a grounding screw. Junction Box Remove conduit and socket head screw (use 5/32 hex key wrench) from center of junction box. Disconnect junction box from solenoid. DIN Plug Connector Remove center screw from DIN plug connector. Disconnect DIN plug connector from adapter. Remove socket head screw (use 5/32 hex key wrench), DIN terminal adapter, and gasket from solenoid. 3. Snap off red cap from top of solenoid base sub-assembly. For 3-way construction with pipe adapter (Figure 3), remove pipe adapter, nameplate and solenoid. Omit steps 4 and 5. 4. Push down on solenoid. Then using a suitable screwdriver, insert blade between solenoid and nameplate/retainer. Pry up slightly and push to remove. NOTE: Series 8202G solenoids have a spacer between the nameplate/ retainer and solenoid. 5. Remove solenoid from solenoid base sub-assembly. 6. Reassemble in reverse order of disassembly. Use exploded views for identification and placement of parts. 7. Torque pipe adapter to 90 inch-pounds maximum [10,2 Nm maximum]. Then make up piping or tubing to pipe adapter on solenoid. Disassembly and Reassembly of Solenoids 1. Remove solenoid, see Solenoid Replacement. 2. Remove spring washer from solenoid base sub-assembly. For 3-way construction, remove plugnut gasket. 3. Unscrew solenoid base sub-assembly from valve body. 4. Remove internal solenoid parts for cleaning or replacement. Use exploded views for identification and placement of parts. 5. If the solenoid is part of a valve, refer to basic valve installation and maintenance instructions for further disassembly. 6. Torque solenoid base sub-assembly and adapter to 175±25 in-lbs [19,8±2,8 Nm]. ORDERING INFORMATION FOR ASCO SOLENOIDS When Ordering Solenoids for ASCO Solenoid Operators or Valves, order the number stamped on the solenoid. Also specify voltage and frequency. Page 2 of 4 Form No.V6584R8 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Torque Chart Part Name solenoid base sub-assembly & adapter pipe adapter Torque Value Inch-Pounds 175 ± 25 90 maximum Remove red cap and push solenoid down. Then pry here to lift nameplate/retainer and push to remove. Remove red cap and push solenoid down. Then pry here to lift nameplate/retainer and push to remove. red cap nameplate/ retainer grounding wire green or green with yellow stripes solenoid with 1/2 NPT finger washer .062 to .093 maximum thickness of panel for mounting core (AC) Torque Value Newton-Meters 19,8 ± 2,8 10,2 maximum 0.69 diameter mounting hole core (DC) Side View finger washer solenoid base sub-assembly Tapped hole in core 0.250-28 UNF-2B 0.63 minimum full thread (AC) 0.38 minimum full thread (DC) collar to face valve body 0.9375-26 UNS -2A thread Alternate Construction Panel Mount Figure 1. Series 8003G solenoids red cap Remove red cap and push solenoid down. Then pry here to lift nameplate/retainer and push to remove. nameplate/ retainer pipe adapter spacer plugnut gasket grounding wire green or green with yellow stripes solenoid with 1/2 NPT spring washer solenoid base sub-assembly bonnet washer core(small end up) solenoid base gasket plugnut assembly cutaway view to show positioning of retainer in gasket recess Without Adapter retainer gasket retainer adapter gasket stem disc disc holder assembly disc spring disc holder spring Figure 2. Series 8202G solenoids adapter Air Only Construction Vent to Atmosphere With Adapter Figure 3. 3-Way Construction Form No.V6584R8 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Page 3 of 4 Torque Chart Part Name terminal block screws socket head screw center screw Torque Value in Inch-Pounds 10 ± 2 15 - 20 5±1 Open-Frame Solenoid with Screw Terminals. Socket head screw is used for grounding. Open-Frame Solenoid with 1/4 Spade Terminals See torque chart above Open-Frame Solenoid with DIN Terminals screw terminal adapter Indicates parts supplied in Termination Module Kit No. K256104 terminal block screw tapped hole for #10-32 grounding screw (not included) Torque Value in Newton-Meters 1,1 ± 0,2 1,7 - 2,3 0,6 ± 0,1 gasket DIN terminal adapter socket head grounding screw (5/32 hex key wrench) socket head screw (5/32 hex key wrench) Figure 4. Open-frame solenoids Junction Box Solenoid with 1/4 Spade Terminals or Screw Terminals screw terminal block (see note) cover screw See torque chart above cover cover gasket grounding screw and cup washer junction box gasket Note: Junction box with screw terminals shown. With screw terminal block removed, remaining parts comprise the junction box for spade terminal construction. junction box with 1/2 conduit connection and grounding terminal socket head screw (5/32 hex key wrench) Figure 5. Junction box (optional feature) Open-Frame Solenoid with DIN Terminal Plug Conector DIN terminal adapter See torque chart above connector gland nut gasket gland gasket socket head screw (5/32 hex key wrench) Notes: 1. Connector cover may be rotated in 90 increments from position shown for alternate position of cable entry. 2. Refer to markings on DIN connector for proper electrical connections. Page 4 of 4 Indicates that these parts are included in DIN plug connector Kit No. K236034 gasket DIN connector terminal block (see note 2) washer center screw connector cover (see note 1) Figure 6. DIN plug connector kit No. K236034 (optional feature) 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Form No.V6584R8 50 Hanover Road Florham Park, New Jersey 07932 Tel. (973) 966-2000 Fax (973) 966 2628 1561 Columbia Highway Aiken, South Carolina 29801 Tel. (803) 641-9200 Fax (803) 641-9290 SCIENTIFIC 50 Hanover Road MMIl All Rights Reserved. Printed in U.S.A. Form No. V6950R5 Florham Park, New Jersey 07932 Tel. (973) 236-6160 Fax (973) 966 6461 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Page 1 of 2 ASCOMATICA S.A. de C.V. Bosques de Duraznos No. 65-1003A Fraccionamiento Bosques de las Lomas Delegacion Miguel Hildago Mexico, D.F. CP11700 Tel: (52)-55-5596-7741 Fax: (52)-55-5596-7719 ASCO Valve Canada P.O. Box 160 (Airport Road) Brantford, Ontario N3T 5M8 Tel: (519) 758-2700 Fax: (519)758-5540 ASCOTECH S.A. de C.V. Circuito Del Progreso No.27 Parque Industrial Progreso Mexicali, B.C. Mexico Tel: (011)-52-686-559-8500 Fax: (011)-52-686-559-8548 MMIl All Rights Reserved. 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Printed in U.S.A. Form No. 6950R5 Page 2 of 2 UNDERWRITERS LABORATORIES, INC. LISTED Pressure Switches UL LISTINGS This sheet is a listing of switch unit and transducer unit combinations that are Listed by Underwriters Laboratories, Inc. The table below is provided to enĆ sure that the proper switch unit (section) is assembled to the proper transducĆ er (section), thus providing a complete, UL Listed pressure switch. Only completely assembled combinations are UL Listed. See table and notes beĆ low for UL complementary product category listing and guide card numbers. SWITCH UNITS See Notes and Form No. P7022R4 INSTALLATION INSTRUCTIONS To determine the proper switch and transducer combinations, first locate the switch unit catalog number in the table below. Then going to the right on the same line (as the switch unit catalog number) find the transducer unit catalog number which may be used with this particular switch unit. IMPORTANT: The third digit in both the switch unit and transducer unit catalog numbers must be identical. For example, a switch unit Catalog No. SC41D can be used with transducer unit Catalog No. TD40A11. The mating produces a complete pressure switch Catalog No. SC41D/TD40A11. PRESSURE TRANSDUCER UNITS See Notes , , and Series: SA, SB, SC, SD, & SE Followed by nos. below Air NonHazardous Oil & Gas Aluminum/ Buna N Construction Air-Water NonHazardous Oil & Steam 303 Stainless Steel & Buna N Construction 42D TA40A11 TA40A31 - - - TA40A32,-42 32D TA30A11 TA30A31 - TA31A11 - TA30A32,-42 21D 22D TA20A11 TA20A31 - TA21A11 - TA20A32,-42 20D 21D 22D TB20A11 TB20A31 - TB21A11 - TB20A32,-42 10D 11D 12D TB10A11 TB10A31 - TB11A11 - TB10A32,-42 10D 11D 12D TC10A11 TC10A31 - TC11A11 - TC10A32,-42 - - TV34A32,-42 General Purpose Enclosure Type 1 Watertight Enclosure Types 3, 3S, 4, & 4X ExplosionĆ proof Enclosure Types 3, 3S, 4, 4X, 7 & 9 40D 41D 30D 31D 20D Applicable Options Corrosive Fluids Air-Water Non-Hazardous Gas & Oil 303 or 316 Stainless Steel & VITON* Construction Fuel Gas Aluminum/Buna N Construction - - Brass & Buna N 32D TV34A11 TV34A21 - 20D 21D 22D TV24A11 TV24A21 - - - TV24A32,-42 40D 41D 42D TD40A11 TD40A21 - TK42A21 - TD40A32,-42 30D 31D 32D TD30A11 TD30A21 TF32A21 TK32A21 TN32B21 TD30A32,-42 20D 21D 22D TD20A11 TD20A21 TF22A21 TK22A21 TN22B21 TD20A32,-42 10D 11D 12D - - TF12A21 TK12A21 TN12B21 - - - - - 316 St. St.& VITON* - - - - 10D 11D 12D - TH13A42 - - - - 10D 11D 12D - TG13A42 - - - - 20D 21D 22D - TG23A42 - - - - 30D 31D 32D - TG33A42 - - - - - - - - - 30D 31D 32D - - - - TN32B42 - 20D 21D 22D - - - - TN22B42 - 10D 11D 12D - - - - TN12B42 - 10D 11D 12D - - - - TQ12B42 - - - - - - 40D 41D 42D - - - TE40A44 - 30D 31D 32D - - - TE30A44 - - 20D 21D 22D TE20A11 TE20A21 - - - TE20A32,-42 10D 11D 12D TE10A11 TE10A21 - TE10A44 - TE10A32,-42 10D 11D 12D TF10A11 TF10A21 - TF10A44 - TF10A32,-42 10D 11D 12D TG10A11 TG10A21 - TG10A44 - TG10A32,-42 10D 11D 12D TH10A11 TH10A21 - TH10A44 - TH10A32,-42 10D 11D 12D TJ10A11 TJ10A21 - TJ10A44 - TJ10A32,-42 10D 11D 12D - TK10A21 - - - TK10A32,-42 10D 11D 12D - TL10A21 - - - TL10A32,-42 10D 11D 12D - TM10A21 - - - TM10A32,-42 10D 11D 12D - TN10B21 - - - TN10B42 10D 11D 12D - - - - - TQ10B42 Switc Sw tch u unit it op ption on su suffixxess 1 or 2. Su Suffix ix K K" 31D ption on iss app cable ble to Se Series es SA a and d SB B onl opt pplica nly. 30D NOTES: All transducers with general purpose and watertight switch units are UL Listed as Industrial Control Equipment-Enclosed, Motor ControllersPressure Operated, Guide NKPZ. Transducers which end in -11, -21, -22, -31, -32, -42 or -44 and used with general purpose and watertight switch units are also UL Listed as switches for Heating and Cooling ApĆ pliances, Guide MFHX. When used with explosionproof switch units, they are UL Listed Industrial Control Equipment for Hazardous Locations Guide NOWT. Brass & Buna N - 316 Stainless Steel & VITON* Fuel Oil-316 Stainless Steel - - When used for steam service, these transducers with general purpose and watertight switch units are also UL Listed as Limit Controls, Guide MBPR. *DuPont's Registered Trademark 50-60 Hanover Road, Florham Park, New Jersey 07932 Switch units with explosionproof enclosures are UL Listed for Class I, Groups B, C, and D (Types 7B, 7C, and 7D) and Class II, Groups E, F, and G (Types 9E, 9F, and 9G) Hazardous Locations. Suffix B is an applicable option. UL Listing also includes transducers TF_2A series with suffix 22, 31, or 32, and TK_2A series with suffix 22. MCMXCII All Rights Reserved. Page 1 of 2 UL approval includes revisions identified by Fifth (V) character letter in industrial switch unit catalog number as follows: General Purpose and Watertight Enclosures Explosionproof Enclosures A - First Construction B - SC switch units redesigned D - Steel balance plate construction B - Class I, Group B (Hydrogen) C - SC switch units redesigned D - Steel balance plate construction UNDERWRITERS LABORATORIES, INC. LISTED Temperature Switches UL LISTINGS This sheet is a listing of switch unit and transducer unit comĆ binations that are Listed by Underwriters Laboratories, Inc. The table below is provided to ensure that the proper switch unit (section) is assembled to the proper transducer (secĆ tion), thus providing a complete, UL Listed pressure switch. Only completely assembled combinations are UL Listed. See table and notes below for UL complementary product category listing and guide card numbers. INSTALLATION INSTRUCTIONS To determine the proper switch and transducer combinaĆ tions, first locate the switch unit catalog number in the table below. Then going to the right on the same line (as the switch unit catalog number) find the transducer unit catalog number which may be used with this particular switch unit. IMPORTANT: The third digit in both the switch unit and transducer unit catalog numbers must be identical. For exĆ ample, a switch unit Catalog No. SA10D can be used with transducer unit Catalog No. QB10A4. The mating produces a complete temperature switch Catalog No. SA10D/QB10A4. TEMPERATURE TRANSDUCER UNITS See Notes and Copper 316 Stainless Steel Cooper (Armored Capillary) 316 Stainless Steel (Plain Capillary) 11D 12D QA10A1 QA10A4 QA11A1 QA11A4 10D 11D 12D QB10A1 QB10A4 QB11A1 QB11A4 10D 11D 12D QD10A1 QD10A4 QD11A1 QD11A4 10D 11D 12D QF10A1 QF10A4 QF11A1 QF11A4 10D 11D 12D QJ10A1 QJ10A4 QJ11A1 QJ11A4 10D 11D 12D QL10A1 QL10A4 QL11A1 QL11A4 10D 11D 12D - - QN11A1 QN11A4 10D 11D 12D - - QT11A1 QT11A4 10D 11D 12D - - QU11A1 QU11A4 O onal Suffi Optio ffixess 1 or 2. S Suffixx K" K" forr Serie ries S SA or SB ly. B only 10D NOTES: All transducers with general purpose and watertight switch units are UL Listed as Temperature - Indicating and Regulating Equipment, Guide XAPX. When used with explosionproof switch units, they are UL Listed Temperature-Indicating and Regulating Equipment for use in Hazardous Locations, Guide XBDV. Optional features, armored capillary and capillary length identified by the seventh, eighth, and ninth digit codes respectively of the transducer catalog number are also UL Listed. Switch units with explosionproof enclosures are UL Listed for Class I, Groups B, C and D (Types 7B, 7C, and 7D) and Class II, Groups E, F, and G (Types 9E, 9F, and 9G) Hazardous Locations. Page 2 of 2 Applicable Options For Capillary & Bulb Only Suf uffixes es C, D, E, E F, & G SWITCH UNITS See Notes and Series: SA, SB, SC, SD, & SE Followed by numbers below ExplosionĆ General Watertight proof Purpose Enclosure Enclosure Applicable Types 3, Options Enclosure Types 3, Type 1 3S,4, & 4X 3S, 4, 4X, 7 &9 Form No. P7022R4 UL approval includes revisions identified by Fifth (V) character letter in industrial switch unit catalog number as follows: General Purpose and Watertight Enclosures A - First Construction B - SC switch units redesigned D - Steel balance plate construction Explosionproof Enclosures B - Class I, Group B (Hydrogen) C - SC switch units redesigned D - Steel balance plate construction 50-60 Hanover Road, Florham Park, New Jersey 07932 Form No.P7022R4 Installation & Maintenance Instructions SWITCH UNITS ADJUSTABLE DEADBAND SWITCH UNIT WITH GENERAL PURPOSE, WATERTIGHT, OR EXPLOSIONPROOF SWITCH ENCLOSURE DESCRIPTION The SA---Series Adjustable Deadband Switch Units are used with transducer units to make Tripoint Pressure Switches or Temperature Switches. The switch units are made of aluminum alloy and designed for rugged industrial use. Switches are provided with a general purpose, watertight, or explosionproof enclosure. All wiring terminals, adjustments, and visual scales are accessible from the front of the switch. The switch may be supplied as a complete unit or with the switch assembly unit and transducer completely assembled. The components may be separate units to be assembled upon installation. The actuation (set) point and the reactuation (reset) point are each independently adjustable over the full range of the switch. The switch assembly can be mated with a wide selection of pressure or temperature transducers to cover a broad range of pressures, fluids, or temperatures. The switch will control electrical circuits in response to changes in pressure or temperature. IMPORTANT: These instructions cover the installation and use of this switch on pressure and temperature transducers. Select the paragraphs that apply to your particular installation and application. The word signal is used in place of pressure, or temperature changes. SA---SERIES Form No.V5720R2 Assembly of Switch and Transducer Units IMPORTANT: The switch unit and transducer unit may be provided as a complete assembly or as separate units. If separate units are provided refer to Form No. V5771 for a complete listing of switch unit and transducer unit combinations. Form No.V5771 is provided to ensure that the proper switch unit is assembled to the proper transducer unit. Pay careful attention to exploded views provided in Figure 3 for assembly of switch unit and transducer unit. Proceed in the following manner: CAUTION: The third digit in the catalog number on both the switch unit and transducer unit must be identical. If not, do not assemble to each other. If the same proceed. 1. Remove special instructions label and switch range scales from transducer unit. 2. For watertight and explosionproof construction place gasket on base of switch unit. 3. Place transducer unit on base of switch unit and assemble. Insert four bolts and torque bolts in a crisscross manner to 80 ± 10 in---lbs [9,0 ± 1,1 Nm]. 4. Remove backing paper from range scale and install scale on the switch body behind adjusting nut. The scale is slotted to fit over a raised boss on the body. See Figure 1. Positioning INSTALLATION Check the nameplate for the correct catalog number, pressure range, temperature range, media, and proof pressure or temperature. Never apply incompatible fluids or exceed the pressure or temperature rating of the switch. Installation and inspection to be performed by qualified personnel. Nameplates are located on cover and on the bottom of the transducer. Check to be sure the third digit in each number is the same. If not, the unit should not be used. (Refer to Figure 3). IMPORTANT: All internal adjustments have been made at the factory. Any adjustment, alteration or repair to the internal parts of the switch other than stated herein voids all warranties. The signal setting adjustments required are made by the adjusting nut on the outside of the switch. Temperature Limitations Ambient temperature limits are — 4_F(—20_C) to 140_F (60_C). To determine fluid temperature limitations, see form No.V5771 for Pressure Transducer catalog numbers and construction materials, then refer to chart below. TRANSDUCER CONSTRUCTION MATERIALS RATINGS FLUID TEMPERATURE Buna N or Neoprene --- 4_ F(--- 20_ C) to 179_ F(82_ C) VITON* --- 4_ F(--- 20_ C) to 250_ F(121_ C) 316 Stainless Steel --- 50_ F(--- 45_ C) to 300_ F(149_ C) For steam service, the fluid temperature with a pigtail (siphon tube or condensate loop) installed directly into the transducer will be below 179_F (82_C). e ASCO Valves Switch may be mounted in any position. Mounting Figure 1 shows partial view of switch body for mounting dimensions. 8,1 .32 Dia. for mounting, 2 places 68 2.69 Figure 1. Mounting locations Piping/Tubing (Pressure Transducer) Adequate support of piping and proper mounting of switch should be made to avoid excessive shock or vibration. To minimize the effect of vibration on a switch, mount perpendicular to vibration. Connect piping or tubing to switch at base of transducer. It is recommended that flexible tubing be used whenever possible. Apply pipe compound sparingly to male pipe threads only. If applied to female threads, it may enter the transducer and cause operational difficulty. Avoid pipe strain on switch by properly supporting and aligning piping. When tightening pipe, do not use switch as a lever. Wrenches applied to transducer body or piping are to be located as close as possible to connection point. IMPORTANT: For steam service, install a condensate loop (pigtail or steam syphon tube) directly into the pressure transducer. CAUTION: To avoid damage to the transducer body, DO NOT OVERTIGHTEN PIPE CONNECTIONS. If TEFLON* tape, paste or similar lubricant is used, use extra care due to reduced friction. IMPORTANT: To eliminate undesirable pressure fluctuations in the system, install a surge suppressor. *DuPont’s Registered Trademark MCMXCI All Rights Reserved. Page 1 of 4 50--- 60 Hanover Road, Florham Park, New Jersey 07932 Wiring Thermal Well (Optional Feature) Wiring must comply with local codes and the National Electrical Code. All switch enclosures are provided with two 3/4I NPT conduit hubs with one plugged when not in use. It is recommended that a flexible conduit connection be used. If rigid conduit is used, do not consider it or use it as a means of support (mounting). For general purpose and watertight constructions, the switch cover is removed by loosening two screws then twisting slightly and lifting. For explosionproof construction, the cover unscrews. When explosionproof cover is replaced, torque cover to 135 ± 10 in---lbs [10,7 ± 1,1 Nm]. Use No. 14 AWG copper wire rated for 60_C minimum. All switches have a grounding screw and clamp in the enclosure. For factory wired switch, black lead is common, red lead is normally open, blue lead is normally closed, and the green lead wire is a ground. IMPORTANT: Electrical load must be within range stated on nameplate. Failure to stay within the electrical range of the switch rating may result in damage to or premature failure of electrical switch. CAUTION: Do not exert excessive screw driver force on snap switch when making terminal connections. When connections are made, be sure there is no stress on the wire leads. Either condition may cause malfunction of switch. ELECTRICAL RATINGS Switch Unit Standard Switch Rating Option K Switch Rating Ratings for Limit Controls and Pressure Operated Switches Ratings for Industrial Controls and Temperature Indicating and Regulating Equipment 5 Amps Res.,125/250 VAC 1/8 HP 125 VAC 1/4 HP 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC 15 Amps Res., 125 VAC 10 Amps Res., 250 VAC 1/4 HP 125 VAC 1/2 HP 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC 5 Amps Res., 125/250 VAC 1/8 HP 125 VAC 1/4 HP 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC 5 Amps Res., 125/250 VAC 1/8 HP 125 VAC 1/4 HP 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC Schematics SPDT DPDT N.O. N.O. C C N.C. N.O. N.C. C A thermal well may be used for capillary and bulb (remote) or direct probe (local) temperature transducers. The thermal well affords protection for the sensing bulb and allows removal of the sensing bulb while maintaining a pressure tight vessel. When installing sensing bulb in thermal well, be sure that it is fully inserted. Where a thermal well already exists, jam nuts may be obtained to adapt the capillary and bulb to the existing thermal well. The existing thermal well must be for a 3/8I diameter sensing bulb. Union Connector (Optional Feature) A union connector will allow direct mounting of the sensing bulb in the fluid being controlled. Install union into piping connection before tightening union onto bulb. For maximum performance, the bulb should be inserted in the union connection so that the end of the sensing bulb is even with the end of the union connector nut. Do not apply excessive torque when tightening union connector nut. Adjustment (Signal Setting) of Adjustable Deadband Switch To make adjustments, (signal setting) a 7/16I wrench and a pressure or temperature gage (within suitable range) are required. If electrical connection (to line of final application) of the switch is not desirable, a battery powered test lamp or ohm meter may be used. Pressure or temperature range scales should be used for initial signal setting. These will be accurate within 5%. Loosen lock ring and turn adjusting nut until red line is even with the desired range. For exact signal setting, proceed as follows: WARNING: To prevent the possibility of personal injury or property damage, turn off electrical power when making permanent electrical connections to switch. Adjustment (Signal Setting) of Normally Closed or Normally Open Switch, Increasing Signal (Refer to Figure 2) 1. If the switch is in the line of final application when adjustment (signal setting) is made, be sure switch can be test operated without affecting other equipment. 2. Loosen lock ring on adjustment nut and turn low signal adjustment nut full upwards and high signal adjustment full down using a 7/16I wrench. CAUTION: Adjusting nut will turn easily until it hits a stop. Do not over torque; over torquing may cause internal damage resulting in malfunction. 3. Remove switch cover to gain access to snap switch. See section on Wiring for cover removal. 4. Follow the steps in the chart below to make signal setting: N.C. NORMALLY CLOSED Standard Switch Suffix K Switch INSTALLATION OF TEMPERATURE TRANSDUCERS Direct Probe The direct probe (local) temperature transducer is provided with 1/2I NPT connection. When installing, do not use switch unit as a lever for tightening. Use wrenching flats provided at base of transducer for tightening. Capillary and Bulb The capillary and bulb (remote) temperature transducers are provided with a length of capillary and a 3/8I diameter sensing bulb. CAUTION: Do not bend capillary at sharp angles. For proper operation, be sure sensing bulb is completely immersed in fluid and not in contact with heating element or anything that would directly affect the temperature of the fluid being sensed. NORMALLY OPEN Adjustment Procedure Switch Terminal Test Lamp On--- Off Switch Terminal Test Lamp On--- Off 1. Starting at zero signal, connect test lamp to common . NC On (Closed Circuit) NO Off (Open Circuit) 2. Apply desired actuation signal. Then back off high signal adjusting nut until switch actuates. NC Off (Open Circuit) NO On (Closed Circuit) 3. Lower signal to desired reactuation signal. Then advance low signal adjusting nut until switch reactuates. NC On (Closed Circuit) NO Off (Open Circuit) 5. Cycle between signal settings and make minor adjustments to adjusting nuts as required to achieve the exact signal setting. 6. After setting has been made, make permanent electrical connections. Page 2 of 4 ASCO Valves Form No.V5720R2 50--- 60 Hanover Road, Florham Park, New Jersey 07932 Adjustment (Signal Setting) of Normally Closed or Normally Open Switch, Decreasing Signal Preventive Maintenance S 1. If the switch is in the line of final application when adjustment (signal setting) is made, be sure switch can be test operated without affecting other equipment. While in service, operate the switch (cycle between desired signals) at least once a month to insure proper operation. If necessary, electrical wiring and pipe connection should be made so that switch can be test operated without affecting other equipment. S 2. Loosen lock ring on adjustment nuts and turn low signal adjustment nut full upwards and high signal adjustment nut slightly beyond desired actuation setting using a 7/16I wrench. Periodic inspection of the switch, external surfaces only, should be carried out. Switch should be kept clean and free from paint, foreign matter, corrosion, icing, and freezing conditions. S Keep the medium entering the transducer as free as possible from dirt and foreign material. (Refer to Figure 2) CAUTION: Adjustment nut will turn easily until it hits a stop. Do not over torque; over torquing may cause internal damage resulting in malfunction. 3. Remove switch cover to gain access to snap switch. See section on Wiring for cover removal. 4. Follow steps in chart below to make signal setting. NORMALLY CLOSED Adjustment Procedures Switch Terminal 1. Starting with initial signal above desired actuation signal, connect test lamp to common . NC NC 2. Decrease signal to desired actuation signal. Then advance low signal adjusting nut until switch actuates. 3. Apply desired reactuation signal. Then back off high signal adjusting nut until switch reactuates. Test Lamp On--- Off NC Causes of Improper Operation Switch will not actuate or actuates and reactuates undesirable. S Incorrect Electrical Connection: Check leads to switch. Be sure they are properly connected. Switch is marked NO for Normally Open, NC for Normally Closed and C for Common. S Faulty Control Circuit: Check electrical power supply to switch. Check for loose or blown fuses, open---circuited or grounded wires, loose connections at terminal block or switch. See nameplate for electrical rating and range. S Incorrect Pressure: Check pressure in system with suitable pressure gage. Pressure must be within range specified on nameplate. S Incorrect Adjustment: Check adjustment nuts for proper setting. Refer to adjustment instructions. S External Leakage: Check to see that bolts (4) holding transducer to pressure switch are properly torqued to 80 ± 10 in---lbs [9,0 ± 1,1 Nm]. If bolts are tight and leakage is still evident, replace transducer. Refer to paragraph on Assembly of Switch Unit and Transducer Unit. S Excessive Vibration or Surges Causing Switch to Actuate and Reactuate: Check for fluctuations in system and install pressure surge suppressor. Check switch mounting and be sure there is no excessive vibration. S Incorrect Temperature: Check temperature in system with suitable thermometer. Temperature must be within range specified on nameplate. Check location of capillary and bulb for incorrect mounting. Refer to paragraphs on Installation of Temperature Transducers. NORMALLY OPEN Switch Terminal Test Lamp On--- Off Off (Open Circuit) NO On (Closed Circuit) On (Closed Circuit) NO Off (Open Circuit) NO Off (Open Circuit) On (Closed Circuit) 5. Cycle between actuation and reactuation signals and make minor adjustment to adjusting nuts as required to achieve the exact signal settings. If the operation of the switch cannot be corrected by the above means, the entire switch unit should be replaced or an authorized factory representative consulted. 6. After settings have been made, tighten lock rings and make permanent electrical connections. Color Code Identification Testing of Installation If the adjustment of the switch has been made outside of the line of final application, the switch should be retested when installed in the line of final application. Follow adjustment instructions. Be sure switch can be test operated without affecting other equipment. MAINTENANCE WARNING: To prevent the possibility of personal injury or property damage, turn off electrical power and depressurize switch unit before inspection or removal. IMPORTANT: Switch is not field repairable. The switch must be returned to the factory (Automatic Switch Company, Florham Park, New Jersey) or serviced only by an authorized factory representative. Address all service inquiries to Automatic Switch Company, 50 ---60 Hanover road, Florham Park, New Jersey 07932, Valve Service Department. The only maintenance which may be performed on the adjustable deadband switch is changing the setting of the adjusting nuts and replacement of the transducer unit. Replacement of transducer should be done only if external leakage is evident. Form No.V5720R2 ASCO Valves When the switch cover is removed, the switch unit may be identified by the color of the sealant used on the locknuts of the snap switch. The color of the sealant will correspond directly to the third digit of the switch catalog number. Third Digit In Catalog Number Sealant Color Used On Snap Switch Locknuts 1 Yellow 2 Green 3 Red 4 Blue Example: If the sealant color on the snap switch was red, this would mean that the third digit in the pressure switch catalog number would be 3, possibly SA 0D. It would not be, for example: SA 0D, SA 0D, or SA 0D. FOR SERVICE, REPLACEMENT, OR NEW TRANSDUCER Consult Factory, or Authorized Factory Representative or Distributors ORDERING INFORMATION For Adjustable Deadband Switch or New Transducer When Ordering, Specify Catalog Numbers, Fluid, Pressure Range, Temperature Range, Serial Numbers, and Proof Pressure or Rated Overrange Temperature. NAMEPLATES ARE LOCATED ON SWITCH COVER AND BOTTOM OF TRANSDUCER. Page 3 of 4 50--- 60 Hanover Road, Florham Park, New Jersey 07932 Enlarged Isometric View Showing Adjusting Nut And Lock Ring Right side, high signal adjusting nut set at 80 psig CAUTION Adjusting nut will turn easily until it hits a stop. DO NOT OVERTORQUE Left side, low signal adjusting nut set at 20 psig scale lines adjusting nut (7/16I wrench) lock ring (tighted securely) line of sight Front View Looking Directly At Adjustable Deadband Switch (Pressure Scales Shown) Figure 2. Adjustment (Signal Setting) of Adjustable Deadband Switch Explosionproof Switch Enclosure Shown IMPORTANT The third digit in Catalog No. on the switch unit and transducer unit must be identical. See example below. switch cover Torque switch cover to _ 1,1 Nm] +10 in---lbs [15,3+ 135 _ adjustable deadband switch unit example Catalog No. SA 2D 3/4I NPT for conduit connection both ends adjusting nut cover (optional) transducer gasket (used on Watertight or Explosionproof Construction only) Torque bolts(4) in a crisscross manner to _ 1,1 Nm] _10 in---lbs [9,0+ 80 + transducer unit example Catalog No. TE 0A42 bolts (4) Figure 3. Switch Unit and Pressure Transducer Unit to be Assembled. Page 4 of 4 ASCO Valves Form No.V5720R2 50--- 60 Hanover Road, Florham Park, New Jersey 07932 SA-SERIES Pressure Switches ADJUSTABLE DEADBAND SWITCH UNIT AND TRANSDUCER UNIT COMBINATIONS DESCRIPTION This sheet is a listing of switch unit and transducer unit combinations. The table below is provided to ensure that the proper switch unit is assembled to the proper transducer unit, thus providing a complete adjustable deadband pressure switch. In the table below locate the switch unit catalog number beĆ ing used. Then going to the right on the same line (as the switch unit catalog number) find the transducer unit catalog number which may be used with this particular switch unit. IMPORTANT: The third digit in both the switch unit and transducer unit catalog numbers must be identical. For example, a switch unit Catalog No. SA41D can be used with transducer unit Catalog No. TD40A11. The mating produces a complete adjustable deadband pressure switch, Catalog No. SA41D/TD40A11. If the third digit is not identical it is an incorrect mate and the units should not be assembled. NOTE: Switch units listed to left may be used with any transducer units listed to right provided they are on the same horizontal line. SPECIFICATIONS SWITCH UNITS Form No.V5771R2 PRESSURE TRANSDUCER UNITS General Purpose Enclosure Type 1 Watertight Enclosure Types 3, 3S, 4, & 4X ExplosionĆ proof Enclosure Types 3, 3S, 4, 4X, 7&9 Adjustable Operating Range (psig) Proof Pressure (psig) Air NonHazardous Oil & Gas Aluminum/ Buna N Construction SA40D SA41D SA42D 0 - 12 W.C. 25 TA40A11 SA30D SA31D SA32D 0 - 27 W.C. 25 TA30A11 SA20D SA21D SA22D 0 - 65 W.C. 25 SA20D SA21D SA22D 15 - 140 W.C. 40 SA10D SA11D SA12D 15 - 250 W.C. 40 SA10D SA11D SA12D 25 - 400 W.C. 40 Air-Water NonHazardous Oil & Steam 303 Stainless Steel & Buna N Construction Fuel Gas Aluminum/ Buna N Construction Corrosive Fluids Air-Water Non-Hazardous Gas & Oil 303 or 316 Stainless Steel & VITON* Construction TA40A31 - TA40A32 TA30A31 TA31A11 TA30A32 TA20A11 TA20A31 TA21A11 TA20A32 TB20A11 TB20A31 TB21A11 TB20A32 TB10A11 TB10A31 TB11A11 TB10A32 TC10A11 TC10A31 TC11A11 TC10A32 TV34A32 - - - - - - Brass & Buna N SA30D SA31D SA32D 0 - 30 Hg 50 TV34A11 TV34A21 - - SA20D SA21D SA22D 15 psi - 30 Hg 50 TV24A11 TV24A21 - TV24A32 SA40D SA41D SA42D 0.4 - 4.5 100 TD40A11 TD40A21 - TD40A42 SA30D SA31D SA32D 0.7 - 9.0 100 TD30A11 TD30A21 - TD30A42 SA20D SA21D SA22D 1.0 - 18 100 TD20A11 TD20A21 - TD20A42 - - - - - - 316 St. St.& VITON* - - SA10D SA11D SA12D 10 - 300 3000 - TH13A42 - - SA10D SA11D SA12D 5 - 200 3000 - TG13A42 - - SA20D SA21D SA22D 5 - 120 3000 - TG23A42 - - SA30D SA31D SA32D 5 - 60 3000 - TG33A42 - - - - - - - - - 316 St. St. & VITON* SA30D SA31D SA32D 200 - 1000 5000 - - TN32B42 - SA20D SA21D SA22D 200 - 2100 5000 - - TN22B42 - SA10D SA11D SA12D 200 - 3500 5000 - - TN12B42 - SA10D SA11D SA12D 500 - 8000 9000 - - TQ12B42 - - - - - - - Brass & Buna N Fuel Oil316 St. St. - SA40D SA41D SA42D 0.8 - 9.0 150 - - TE40A44 - SA30D SA31D SA32D 1.0 - 18 150 - - TE30A44 - SA20D SA21D SA22D 1.5 - 36 150 TE20A11 TE20A21 - TE20A42 SA10D SA11D SA12D 2 - 60 150 TE10A11 TE10A21 TE10A44 TE10A42 SA10D SA11D SA12D 3 - 100 200 TF10A11 TF10A21 TF10A44 TF10A42 SA10D SA11D SA12D 6 - 200 400 TG10A11 TG10A21 TG10A44 TG10A42 SA10D SA11D SA12D 13 - 300 600 TH10A11 TH10A21 TH10A44 TH10A42 SA10D SA11D SA12D 15 - 400 600 TJ10A11 TJ10A21 TJ10A44 TJ10A42 SA10D SA11D SA12D 30 - 600 900 - TK10A21 - TK10A42 SA10D SA11D SA12D 50 - 1000 1500 - TL10A21 - TL10A42 SA10D SA11D SA12D 75 - 1500 2300 - TM10A21 - TM10A42 SA10D SA11D SA12D 200 - 3500 5000 - TN10B21 - TN10B42 SA10D SA11D SA12D 500 - 8000 9000 - - - TQ10B42 - - - - - - - Brass & Buna N - SA30D SA31D SA32D 1.5 - 30 200 - - TF32A21 - SA20D SA21D SA22D 2.0 - 60 200 - - TF22A21 - SA10D SA11D SA12D 3.0 - 100 200 - - TF12A21 - SA40D SA41D SA42D 10 - 75 200 - - TK42A21 - SA30D SA31D SA32D 10 - 150 400 - - TK32A21 - SA20D SA21D SA22D 10 - 300 400 - - TK22A21 - SA10D SA11D SA12D 30 - 600 900 - - TK12A21 - SA30D SA31D SA32D 200 - 1000 5000 - - TN32B21 - SA20D SA21D SA22D 200 - 2100 5000 - - TN22B21 - SA10D SA11D SA12D 200 - 3500 5000 - - TN12B21 - Proof pressure TA_1A_ 15 psig/TB_1A_+ TC_1A_ 25 psig. ASCO Valves MCMXCIII All Rights Reserved. *DuPont's Registered Trademark Printed in U.S.A. Page 1 of 2 50-60 Hanover Road, Florham Park, New Jersey 07932 SA-SERIES Temperature Switches ADJUSTABLE DEADBAND SWITCH UNIT AND TRANSDUCER UNIT COMBINATIONS DESCRIPTION This sheet is a listing of switch unit and transducer unit comĆ binations. The table below is provided to ensure that the proper switch unit is assembled to the proper transducer unit, thus providing a complete adjustable deadband temĆ perature switch. In the table below locate the switch unit catalog number being used. Then going to the right on the same line (as the switch unit catalog number) find the transĆ ducer unit catalog number which may be used with this parĆ ticular switch unit. SWITCH UNITS WaterĆ tight g General E l EncloĆ P Purpose sure Enclosure Types 3, 3 T Type 1 3S, 4, 4X IMPORTANT: The third digit in both the switch unit and transducer unit catalog numbers must be identical. For exĆ ample, a switch unit Catalog No. SA10D can be used with transducer unit Catalog No. QD10A1. The mating produces a complete temperature switch Catalog No. SA10D/QD10A1. If the third digit is not identical it is an inĆ correct mate and the units should not be assembled. NOTE: Switch units listed to left may be used with any transducer units listed to right provided they are on the same horizontal line. SPECIFICATIONS Explosion proof Enclosure Types 3, 3S, 4, 4X, 7&9 SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D SA10D SA11D SA12D Page 2 of 2 ASCO Valves Adjustable j O Operating i Range g (_F and d _C) -30 to 60_F -34 to+16_C 0 to 90_F -18 to+32_C 50 to 160_F 10 to 71_C 100 to 220_F 38 to 104_C 160 to 260_F 71 to 127_C 225 to 340_F 107 to 171_C 300 to 450_F 149 to 232_C 350 to 510_F 177 to 266_C 425 to 640_F 218 to 337_C TRANSDUCER UNITS Maximum Rated Overrange Temperature (_F and _C) Direct Mount 250_F 121_C 260_F 127_C 260_F 127_C 260_F 127_C 260_F 127_C - Form No.V5771R2 Capillary Copper S.S. 250_F 121_C 300_F 149_C 350_F 177_C 450_F 232_C 500_F 260_C 550_F 287_C 550_F 287_C 550_F 287_C - 250_F 121_C 300_F 149_C 350_F 177_C 450_F 232_C 500_F 260_C 600_F 316_C 700_F 371_C 800_F 427_C 890_F 477_C 6' Capillary and Bulb Direct Mount Copper 316 S.S. Copper Armored Capillary 316 S.S. Plain Capillary Catalog No. Catalog No. Catalog No. Catalog No. QB10A1 QB10A4 QB11A1 QB11A4 QD10A1 QD10A4 QD11A1 QD11A4 QF10A1 QF10A4 QF11A1 QF11A4 QJ10A1 QJ10A4 QJ11A1 QJ11A4 QL10A1 QL10A4 QL11A1 QL11A4 - - QN11A1 QN11A4 - - QT11A1 QT11A4 - - QU11A1 QU11A4 - - - QW11A4 Form No.V5771R2 50-60 Hanover Road, Florham Park, New Jersey 07932 Innovative Liquid Vaporizing and Gas Mixing Solutions WARRANTY REGISTRATION Type of Equipment: Serial Number: ASDI Sales Order #: Order Date: Purchased By: To help us give you better service, please fill out this warranty registration form and return it to ASDI to register your purchase and for follow up on the performance of ASDI equipment. We are dedicated to producing a quality product and if a problem occurs, ASDI wants to know about it. Please help us with a small amount of information about your company and how the equipment will be used. When contacting ASDI, please have the type of equipment and the serial number handy so we can give you accurate information. If you have had any kind of problem with this equipment, or you have any comments, please attach a separate sheet to this form. Keep a copy for your records. End Customer/Company Name: Address: Tel: City: Fax: State: Zip: Name of individual to contact for follow up information: Title: Usage - Circle one: Base Load Standby System Peak Shaving Other: In what application is the equipment being used? When was the equipment put in service? Note: If you have more than one piece of ASDI equipment, fill out one warranty sheet and staple the others to it, ASDI will do the rest. 151 South Michigan Street, Tel: 206.789..5410 E-mail: [email protected] Seattle, Washington, 98108, USA Fax: 206.789.5414 Internet: www.algas-sdi.com Power Equipment Company Manufacturers’ Representative & Distributor 2011 Williamsburg Road Richmond, Virginia 23231 T: 804-236-3800 F: 804-236-3882 [email protected] www.peconet.com ">
/
Descarcă
Doar o reamintire prietenoasă. Poți vizualiza documentul chiar aici. Dar cel mai important, AI-ul nostru l-a citit deja. Poate explica lucruri complexe în termeni simpli, poate răspunde la întrebările tale în orice limbă și te poate ajuta să navighezi rapid chiar și prin cele mai lungi sau mai complicate documente.
Publicitate