Quick Install Guide

3-9000-780 Rev A

September 2014

3410/3810 Series Local Display Field Install Kit

Local Display Field Install Kit

September 2014

Daniel customer service

Quick Install Guide

3-9000-780 Rev A

Location

North America/Latin America

Daniel Customer Service

USA (toll free)

Asia Pacific (Republic of Singapore)

Europe (Sterling Scotland, UK)

Middle East Africa (Dubai, UAE)

E-mail

Customer Service:

• Customer Support:

• Asia-Pacific:

• Europe:

Telephone number

+1.713.467.6000

+1.713.827.6413

+1.888.356.9001

+65.6777.8211

+44 (0)1786.433400

+971 4 8118100

Fax number

+1.713.827.4805

+1.713.827.6312

+1.713.827.3380

+65.6777.0947.0743

+44 (0)1786.433401

+971 4 8865465

[email protected] [email protected] [email protected]

[email protected]

Return Material Authorization (RMA)

A Return Material Authorization (RMA) number must be obtained prior to returning any equipment for any reason.

Download the RMA form from the Support Services web page by selecting the link below. www2.emersonprocess.com/EN-US/BRANDS/DANIEL/SUPPORT-SERVICES/Pages/Support-Services.aspx?

3

Local Display Install Kit

Local Display Field Install Kit

September 2014

Signal words and symbols

Pay special attention to the following signal words, safety alert symbols and statements:

Quick Install Guide

3-9000-780 Rev A

This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

Notice is used to address safety messages or practices not related to personal injury.

Important

Important is a statement the user needs to know and consider.

Tip

Tip provides information or suggestions for improved efficiency or best results.

Note

Note is a “general by-the-way” content not essential to the main flow of information.

4

Local Display Install Kit

Local Display Field Install Kit

September 2014

Component disassembly

Quick Install Guide

3-9000-780 Rev A

1. Local Display Field Install Kit Includes.

5 4

8

2 1

3

• Preassembled assemblies and parts:

-

LCD Display Board, Shroud, LCD Module

-

Cover – Housing (glass end cap) with O-Ring

-

Backplane board

-

Pan HD Screws #6-32 X .88

2. Local Display Field Install Kit Parts List.

ITEM * QTY DESCRIPTION

5

6

7

1

2

3

4

1

1

1

1

1

2

1

Preassembled:

LCD Display Field Install Kit

LCD Display Board

LCD Display Shroud

Pan HD Screw PH SEMS #6-32 X .38 M/S W/410 EXT 18-8 SST

LCD Module

Preassembled:

Cover – HSG LCD Type FB100

O-Ring #2-245

Backplane Board 3410/3810

8 4 Pan HD Screw PH SEMS #6-32 X .88

*

Note:

Item numbers correlate with DMC-009079 - 3410/3810 Series LCD Module

Local Display Install Kit

5

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

3. Check firmware version before powering off the meter.

Application options:

Daniel MeterLink™

AMS® Device Manager

Field Communicator

Requirements: Firmware Version 1.06 and Uboot Version January 31, 2013 or later.

If necessary to upgrade firmware,

-

Open Daniel MeterLink and connect to the meter.

-

Open an Internet browser.

-

Navigate to the Daniel website:

www.Daniel.com

.

-

Use Quick Links and click MeterLink Registration and Download to access the latest firmware.

Local Display Install Kit

-

Go to Daniel MeterLink and use the Tools|Program Download menu to download a file to the meter. Click Open to display an Open Download File dialog. Select the desired file and click Open. Daniel MeterLink™ only downloads components that are different than what is currently installed in the meter.

6

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

CPU

TB-2

4. Remove power to the equipment and remove transmitter electronics enclosure endcaps.

Remove endcap security seals, if installed, and security latches.

Remove power from equipment before removing endcaps if possible and/or ensure explosive atmosphere is not present before opening the transmitter electronics enclosure.

Unplug CPU Module terminal board connectors (TB-1 and TB-2).

Unplug I/O Module, and Power Supply terminal board connectors.

Pull the CPU and I/O Modules from the enclosure.

24V Loop

Power

10.4VDC - 36VDC

Power

CPU

TB-1

I/O Module

Connectors

Local Display Install Kit

7

Local Display Field Install Kit

September 2014

5. Remove the Backplane board.

Backplane

Board

Remove four screws with lock washers.

Pull Backplane from housing.

Remove Power Supply and I.S. Barrier boards from Backplane.

6. Disconnect the Acquisition cable.

Acquisition

Cable

Quick Install Guide

3-9000-780 Rev A

I.S. Barrier

Board

Power Supply

Board

7. Components disassembly complete.

Local Display Install Kit

8

Local Display Field Install Kit

September 2014

Component assembly

Quick Install Guide

3-9000-780 Rev A

1. Backplane Board with 14 pin connector.

14 Pin

Connector

Backplane

Board

Note:

Check existing 3410/3810 Series Backplane board (P/N 1-360-03-007) Rev D minimum for 14 pin connector (J8).

If equipped, use this board. If not, use board included with the Local Display Field

Install Kit.

Acquisition

Cable

Attach Acquisition cable to Backplane.

Tighten connector screws.

Local Display Install Kit

9

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

2. Plug Power Supply Board and I.S. Barrier Module onto Backplane

Board with 14 pin connector.

I.S. Barrier Board

Backplane Board

Power Supply Board

3. Plug Local Display Board into the Backplane 14 Pin connector.

14 Pin Connector

Local Display Board

Make sure LCD Board is fully seated to Backplane 14 pin connector.

Local Display Install Kit

10

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

4. Slide Backplane, Power Supply, I.S. Barrier Module and Local

Display Module assembly into transmitter enclosure and fasten with 4 Pan Head screws.

Make sure boards are aligned in the enclosure and I.S. Barrier Board is inside the guide plate key retainer.

Use the long Pan HD Screws #6-32 X .88 provided with the kit.

5. Install endcap with sight glass.

Make sure endcap O-ring is installed.

Local Display Install Kit

11

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

6. Reinstall CPU Module and I/O Module in the enclosure.

7. Install CPU Module TB-1 and TB-2 and I/O Module terminal connectors.

CPU

TB-2

CPU

TB-1

I/O Module

Connectors

Local Display Install Kit

12

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

8. If explosive atmosphere is not present, connect the Power

Supply terminal connectors and apply power to the unit.

24V Loop

Power

10.4VDC - 36VDC

Power

Ensure all CPU LEDs are green.

CPU LEDs

Observe Local Display startup sequence (see

Step 10 ).

Local Display Install Kit

13

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

9. If explosive atmosphere is present, install endcaps and apply site power to equipment.

Endcap security latch

Reinstall endcap security latches.

Apply site power.

Note:

If explosive atmosphere is present and site power initializes the unit, a Service technician should observe the Local Display startup sequence (see

Step 10

).

10. Observe Local Display startup sequence.

Local Display

Startup sequence –

All segments displayed

2 seconds after power up, the “DANIEL” logo appears at the bottom of the LCD screen.

The Checksum displays.

Make sure all segments are displayed (all the segments will come on and stay on for about 4 seconds). Pay careful attention and make sure that all segments are functioning and no segments are missing.

The Wait command displays, and then the four default Display Items scroll on the display.

Local Display Install Kit

14

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

11. Configure display items, measurement units and scroll delay.

Configuration applications options:

Daniel MeterLink™ - Field Setup Wizard (see image above)

AMS® Device Manager

Reference manuals:

(

AMS Suite: Intelligent Device Manager

Field Communicator

(

Field Communicator

)

)

-

3-9000-761 Rev 4 HART® Field Device Specification 3410 Series Gas Ultrasonic Meters

-

3-9000-762 Rev 4 HART® Field Device Specification 3810 Series Liquid Ultrasonic Meters

-

3-9000-759 Rev D 3410 Series Gas Ultrasonic Meters Installation Manual

-

3-9000-760 Rev C 3810 Series Liquid Ultrasonic Meters Installation Manual

-

3-9000-765 Rev C 3812 Liquid Ultrasonic Meters Installation Manual

12. Reinstall wire security seals on the endcaps, if necessary.

13. Installation complete.

3410/3810 Series

Transmitter with Local

Display

Local Display Install Kit

15

Local Display Field Install Kit

September 2014

Quick Install Guide

3-9000-780 Rev A

Local Display Install Kit

16

P/N 3-9000-780

Rev A

2014

Daniel Measurement and Control, Inc.

11100 Brittmoore Park Drive

Houston, TX 77041 USA

T+1 713-467-6000

F+1 713-827-4805

USA Toll Free 1 888-356-9001

Daniel Measurement Services, Inc.

T +1 713-827-6413

www.Daniel.com

Europe: Sterling, Scotland, UK

T + 44-1786-433400

Middle East: Africa: Dubai, UAE

T +971-4-811-8100

Asia Pacific: Singapore

T +65-677-8211

This product is a core component of the PlantWeb® digital plant architecture.

© 2014 Daniel Measurement and Control, Inc., All rights reserved

The Emerson logo is a trademark and service mark of Emerson Electric Co. Daniel

Measurement and Control, Inc. (Daniel) are Emerson Process Management business units.

The Daniel name and logo are trademarks of Daniel Industries, Inc. The Senior, Junior,

Simplex, MeterLink SeniorSonic, JuniorSonic, and DanPac are trademarks of Daniel

Industries, Inc. All other trademarks are property of their respective owners.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement