Microlife NC 100, NC 150 Instruction manual
Add to my manuals
11 Pages
Microlife NC 150: The Non-Contact thermometer reliably measures body temperature and the temperature of objects. Get accurate results in just one second, with a reading accuracy of ±0.2°C. Choose Celsius or Fahrenheit, and switch between body and object mode. Store up to 30 measurements.
advertisement
▼
Scroll to page 2
of 11
Guarantee Card Hypertension NC 100 Human Fever Asthma Europe / Middle-East / Africa Microlife AG Espenstrasse 139 9443 Widnau / Switzerland Tel. +41 / 71 727 70 30 Fax +41 / 71 727 70 39 Email [email protected] www.microlife.com Asia Microlife Corporation. 9F, 431, RuiGang Road, NeiHu Taipei, 11492, Taiwan, R.O.C. Tel. 886 2 8797-1288 Fax.886 2 8797-1283 Email [email protected] www.microlife.com North / Central / South America Microlife USA, Inc. 1617 Gulf to Bay Blvd., 2nd Floor Ste A Clearwater, FL 33755 / USA Tel. +1 727 442 5353 Fax +1 727 442 5377 Email [email protected] www.microlife.com Flexible Heating IB NC 100 EN-PL 2313 Microlife NC 100 EN Ä 2 PL Ä 8 Microlife NC 100 1 2a 2b 3 Microlife Non Contact Thermometer NC 100 Microlife NC 100 1 8 AN 9 AO AT AP AK AQ AL AR AM AS 1 2 3 4 5 6 7 8 9 AT AK AL AM AN AO AP AQ AR 2 Measuring sensor Tracking light START button Display ON/OFF button Mode switch Battery compartment cover All segments displayed Memory Ready for measuring Measurement complete Body mode Object mode Low battery indicator Changing between Celsius and Fahrenheit Recall mode Recall the last 30 readings Measured temperature too high AS BT BK BL BM BN BO Measured temperature too low Ambient temperature too high Ambient temperature too low Error function display Blank display Flat battery Replacing the battery Read the instructions carefully before using this device. Type BF applied part EN This Microlife thermometer is a high quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, this device can provide a stable, heat-interference-free reading with each measurement. The device performs a self-test every time it is switched on to always guarantee the specified accuracy of any measurement. This Microlife thermometer is intended for the periodic measurement and monitoring of human body temperature. This thermometer has been clinically tested and proven to be safe and accurate when used in accordance to the operating instruction manual. Please read through these instructions carefully in order for you to understand all functions and safety information. Guarantee Card Name of Purchaser / Imię i nazwisko nabywcy Serial Number / Numer seryjny Date of Purchase / Data zakupu Specialist Dealer / Przedstawiciel NC 100 vated blue tracking light will indicate the area being measured. After 3 seconds a long beep will verify the completion of measurement. If the temple area hasn’t been reached before the long beep is heard, repeat the measurement as described above, but move the thermometer a little faster. 6. Read the recorded temperature from the LCD display. Measuring in object mode 1. Follow steps 1-3 above, then aim the thermometer at the center of the object you want to measure with a distance of no more than 5 cm. Press the START button 3. After 3 seconds a long beep will verify the completion of measurement. 2. Read the recorded temperature from the LCD display. NOTE: Patients and thermometer should stay in similar room condition for at least 30 minutes. Don't take a measurement while or immediately after nursing a baby. Don't use the thermometer in high humidity environments. Patients should not drink, eat or exercise before/while taking the measurement. Don't move the measurement device from the measuring area before hearing the termination beep. NC 100 Use an alcohol swab to carefully clean the probe and wait for 15 minutes before taking a measurement on another patient. 10 short beeps and a red LCD backlight alerts the patient that he/she may have a temperature equal to or higher than 37.5 °C. Always take the temperature in the same location, since temperature readings may vary according to locations. Doctors recommend rectal measurement for newborn infants within the first 6 months, as all other measuring methods might lead to ambiguous results. If using a non contact thermometer on those infants, we always recommend verifying the readings with a rectal measurement. In the following situations it is recommended that three temperatures are taken with the highest one taken as the reading: 1. Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical. 2. When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/ herself with the device and obtains consistent readings. 3. If the measurement is surprisingly low. Readings from different measuring sites should not be compared as the normal body temperature varies by measuring site and time of day, being highest in the evening and lowest about one hour before waking up. Normal body temperature ranges: - Axillar: 34.7 - 37.3 °C / 94.5 - 99.1 °F - Oral: 35.5 - 37.5 °C / 95.9 - 99.5 °F - Rectal: 36.6 - 38.0 °C / 97.9 - 100.4 °F - Microlife NC 100: 35.4 - 37.4 °C / 95.7 - 99.3 °F 7. Changing between Celsius and Fahrenheit This thermometer can display temperature readings in either Fahrenheit or Celsius. To switch the display between °C and °F, simply turn OFF the unit, press and hold the START button 3 for 5 seconds; after 5 seconds, the current measurement scale («°C» or «°F» icon) will flash on the display AO. Change the measurement scale between °C and °F by pressing the START button 3. When the measurement scale has been chosen, wait for 5 seconds and the unit will automatically enter the «ready for measuring» mode. 8. How to recall 30 readings in Memory Mode This thermometer can recall the last 30 readings. Recall mode AP: Press the START button 3 to enter Recall mode when power is off. The memory icon «M» will flash. 5 EN Reading 1 - the last reading AQ: Press and release the START button 3 to recall the last reading. Display 1 alone with memory icon. Reading 30 - readings in succession: Press and release the START button 3 consecutively to recall the last 30 readings in succession. Pressing and releasing the START button 3 after the last 30 readings have been recalled will resume the above sequence from reading 1. Error function display BL: The system has a malfunction. Batteries and electronic devices must be dis Blank display BM: Check if the batteries have been posed of in accordance with the locally applicable inserted correctly. Also check polarity (<+> and <->) of regulations, not with domestic waste. the batteries. Flat battery indicator BN: If only «» icon is shown on 12.Guarantee the display, the batteries should be replaced immediately. This device is covered by a 2 year guarantee from the date of purchase. The guarantee is valid only on presentation of 10.Cleaning and Disinfecting the guarantee card completed by the dealer (see back) Use an alcohol swab or cotton tissue moistened with confirming date of purchase or the receipt. alcohol (70% Isopropyl) to clean the thermometer casing The guarantee covers the device. Batteries and pack9. Error Messages and the measuring sensor. Ensure that no liquid enters the aging are not included. Measured temperature too high AR: Displays «H» interior of the device. Never use abrasive cleaning agents, Opening or altering the device invalidates the guarantee. when measured temperature is higher than 42.2 °C / thinners or benzene for cleaning and never immerse the The guarantee does not cover damage caused by 108.0 °F in body mode or 100 °C / 212 °F in object mode. device in water or other cleaning liquids. Take care not to improper handling, discharged batteries, accidents or Measured temperature too low AS: Displays «L» scratch the surface of the sensor lens and the display. non-compliance with the operating instructions. when measured temperature is lower than 34.0 °C / Please contact Microlife-service. 11.Battery Replacement 93.2 °F in body mode or 0 °C / 32 °F in object mode. Ambient temperature too high BT: Displays «H» This device is supplied with 2 new, long-life 1.5V, size AAA 13.Technical Specifications and when ambient temperature is higher than batteries. Batteries need replacing when this icon «» BN Type: Non Contact Thermometer NC 100 40.0 °C / 104.0 °F. is the only symbol shown on the display. MeasureBody mode: 34.0-42.2 °C / 93.2-108.0 °F Ambient temperature too low BK: Displays «L» and Use a screwdriver to open the battery cover BO. when ambient temperature is lower than 16.0 °C / Replace the batteries – ensure correct polarity as shown by ment range: Object mode: 0-100.0 °C / 32-212.0 °F 60.8 °F in body mode or lower than 5.0 °C / 41.0 °F in the symbols in the compartment. Resolution: 0.1 °C / °F object mode. 6 Measurement accuracy: Display: Acoustic: Memory: NC 100 Laboratory: 0.2 °C, 36.0 39.0 °C (0.4 °F, 96.8 102.2 °F) Liquid Crystal Display, 4 digits plus special icons The unit is turned ON and ready for the measurement: 1 short beep Complete the measurement: 1 long beep (1 sec.) if the reading is less than 37.5 °C / 99.5 °F, 10 short «beep» sounds, if the reading is equal to or greater than 37.5 °C / 99.5 °F. System error or malfunction: 3 short «bi» sounds Auto-Display the last measured temperature 30 readings recall in the memory mode Backlight: The display light will be GREEN for 4 seconds, when the unit is turned ON. The display light will be GREEN for 5 seconds, when a measurement is completed with a reading less than 37.5 °C / 99.5 °F. The display light will be RED for 5 seconds, when a measurement is completed with a reading equal to or higher than 37.5 °C / 99.5 °F. Operating Body mode: 16-40.0 °C / 60.8-104.0 °F temperature: Object mode: 5-40.0 °C / 41-104.0 °F Storage -20 - +50 °C / -4 - +122 °F temperature: 15-95 % relative maximum humidity Automatic Approx. 1 minute after last measurement Switch-off: has been taken. Battery: 2 x 1.5 V Batteries; size AAA Dimensions: 150 x 40 x 39 mm Weight: 81 g (with batteries), 56 g (w/o batteries) Reference to ASTM E1965; standards: IEC 60601-1; IEC 60601-1-2 (EMC) This device complies with the requirements of the Medical Device Directive 93/42/EEC. Technical alterations reserved. According to the Medical Product User Act a biennial technical inspection is recommended for professional users. Please observe the applicable disposal regulations. 14.www.microlife.com Detailed user information about our thermometers and blood pressure monitors as well as services can be found at www.microlife.com. 7 EN 1 2 3 4 5 6 7 8 9 AT AK AL AM AN AO AP 8 AR AS BT BK BL BM BN BO NC 100 9 PL 10 4. Symbole kontrolne NC 100 11 PL 12 NC 100 Akustyka: 13 PL
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project