BFT Argo, ARGO G Telepítési útmutató
PDF
Dokumentum
Hirdetés
Hirdetés
027908 D811627 00100_04 28-01-11 8 347060 ISTRUZIONI DI INSTALLAZIONE INSTALLATION MANUAL INSTRUCTIONS D’INSTALLATION Montageanleitung INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN ARGO ARGO G AUTOMAZIONI PER PORTE SEZIONALI INDUSTRIALI OPERATORS FOR INDUSTRIAL SECTIONAL DOORS AUTOMATISMES POUR PORTES MULTI-LAMES INDUSTRIELLES AUTOMATISCHE ANTRIEBE FÜR INDUSTRIE-SEKTIONALTORE AUTOMATISMOS PARA PUERTAS SECCIONALES INDUSTRIALES AUTOMATISERINGEN VOOR INDUSTRIËLE OPDRACHTGERICHTE DEUREN A 2 V1 5 mm 10 mm V2 (Fig. C4) 1 20 mm 10 mm V1 C B M 1 230Volt PHOT PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT, INSTALLATION DES TUBES, VORBEREITUNG DER LEITUNGEN, DISPOSICIÓN DE TUBOS, VOORINSTELLING BUIZEN V2 3 4 2 7 5 2- ARGO-ARGO G 6 8 D811627 00100_04 INSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE D811627 00100_04 ITALIANO D E 1,6 AT Led presenza alimentazione, Power ON LED, Voyant LED présence d'alimentation, Led Vorhandensein Stromversorgung, Led Presencia de Alimentación, Led Aanwezigheid voeding Display + tasti programmazione Display plus programming keys Afficheur et touches de programmation Display und Programmierungstasten Pantalla más botones de programación Display meerdere toetsen programmeur 16 17 11 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PARZ./CLOSE Connettore scheda opzionale Optional board connector Connecteur carte facultative Steckverbinder Zusatzkarte Conector de la tarjeta opcional Connector optionele kaart. 24V MAX 180mA BAR ANT 14 15 12 13 16 17 SCA / 2CH (NO) 1 2 3 4 5 6 7 fine-end-fin ARGO-ARGO G - 3 NEDERLANDS FAULT PHOT Modulo opzionale SCS-I0, Optional SCS-IO module Module en option SCS-IO, Optional module SCS-IO Módulo opcional SCS-IO, Zusatzmodul SCS-IO AUTOSET COPPIA APERTURA-CHIUSURA OPENING-CLOSING TORQUE AUTOSETTING RÉGLAGE AUTOMATIQUE COUPLE OUVERTURE-FERMETURE AUTOSET DREHMOMENT ÖFFNUNG-SCHLIESSUNG AJUSTE AUTOMATICO DEL PAR EN FASE DE APERTURA-CIERRE AUTOSET DRAAIMOMENT OPENING - SLUITING. G 8888 A OK OK x2 B PArAM logic C OK D radio OK AGG.START-adjouter startzufueg.start-anad.start tasto nascosto-hidden buttontouche cachee-verst.taste rilascia-release relache-loslassen suelte tasto desiderato desidered button-touche desiree gevue taste-tecla deseada x2 o end 4- ARGO-ARGO G 01 D811627 00100_04 F D811627 00100_04 226.5 min 226.5 65.5 min. H 86 341 max 292 351 378 77 59 86 22 115 180 max Ingresso cavi dall'alto, Cable entry from above, Entrée câbles du haut, Kabeleingang von oben, Entraa cables desde arriba, Ingang kabels van de hoogte I APERTURA (inv.mot.=OFF) TO OPEN (change mot.=OFF) OUVERTURE (inv.mot.=OFF) ÖFFNUNG (mot.tausch=OFF) APERTURA (inv.mot.=OFF) OPENING (change mot.=OFF) Ingresso cavi dalla parete, Cable entry from wall, Entrée câbles du réseau, Kabeleingang von Wand, Entrada cables desde la pared, Ingang kabels van de wand Ingresso cavi dal basso, Cable entry from below, Entrée câbles du bas, Kabeleingang von unten, Entrada cables desde abajo, Ingang kabels van beneden 230V 24V J ø 250 350 [Numero manovre / giorno] [Number of operations/day] [Nombre manœuvres / jour] [Anzahl Manöver / Tag] [Número maniobras / día] [Aantal manoeuvres / dag] ø 225 300 ø 200 ø 175 250 ø 150 200 ø 125 150 ø 100 100 50 0 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 ARGO-ARGO G - 5 Reeds gememoriseerde afstandsbediening Reeds gememoriseerde afstandsbediening Te memoriseren afstandsbediening COSTE LEISTEN Te memoriseren afstandsbediening L 1 2 TX1 RX1 1-PHOT 12 13 12 13 1 2 TX1 RX1 6 1 2 3 10 11 3 5 6 3 11 10 1 2 3 4 5 10 11 12 7 3 1 2 3 4 5 10 11 4 1 2 TX1 RX1 2-PHOT 12 13 5 4 1-PHOT 3 10 11 3 1 2 TX2 RX2 3 11 10 1-BAR B 6 5 4 3 2 1 Bar 1 12 7 1-BAR C 6 5 4 3 2 1 Bar 1 11 10 3 6 A 6 5 4 3 2 1 Bar 1 7 1 2 3 2-BAR 6 5 4 3 2 1 Bar 2 2 SCS-IO 3 11 10 TEST BAR= OFF 10 11 1 2 3 4 5 6 7 16 17 TEST BAR = ON 1 24V~ (+) 24V~ (-) V SAFE (+) V SAFE (-) PHOT BAR COM TEST PHOT= OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 TEST PHOT = ON FAULT PHOT Combinazioni possibili, Possible combinations, Combinaisons possibiles, Mögliche Kombinationen, Combinaciones posibles, Mogelijke combinaties CANTOS LINTEAUX SAFETY EDGES RANDEN COSTE LEISTEN A B C A B C A B C 1 1 1 2 2 2 3 3 3 PHOTOCELLULES PHOTOCELLS Connessione Seriale Mediante Scheda Scs1 , Serial Connection Via Scs1 Card, Connexion Série À Travers La Carte Scs1, Serielle Verbindung Mit Karte Scs1, Conexión Serial Mediante Tarjeta Scs1, Seriële Verbinding Middels Kaart Scs1 6- ARGO-ARGO G M D811627 00100_04 K PROGRAMMAZIONE TRASMETTITORI REMOTA, REMOTE TRANSMITTER PROGRAMMING, PROGRAMMATION ÉMETTEURS A DISTANCE, FERNPROGRAMMIERUNG DER SENDER, PROGRAMACION DE TRANSMISORES REMOTA, REMOTE PROGRAMMERING TRANSMITTERS D811627 00100_04 ITALIANO param. 1 param. 2 fine param. . . . logic logic. 1 logic. 2 fine logic. . . . radio Agg. start tasto nascosto tasto desiderato o 01 Agg 2ch tasto nascosto tasto desiderato o 01 fine 01 t1 Leggi Elimina 64 PRG. +/COD RX 1A9C OK 22FD OK 01 OK v lingua ITA OK - + FRA OK - + fine DEU OK - + ENG OK - + esp default OK PRG PED STRe STOP PHOT BAR CLOS OPEN Suo Suc A P SET fine (Fig. F) autoset fine REGOLAZIONE FINECORSA fine ARGO-ARGO G - 7 8- ARGO-ARGO G AVVERTENZE PER L’INSTALLATORE D811766_02 D811627 00100_04 D811627 00100_04 230V ±10%, 50/60Hz (*) 240W Lampada 24V~ 25W max, E14 ARGO: 20mq ARGO G: 35mq ARGO: 55Nm ARGO G: 80Nm ARGO: 30 min ARGO G: 18 min-1 Manovra manuale: IP 40 <70dBA 10 kg Dimensioni : Vedi Fig. H 24V~ (180 mA) 24V max 25W Fusibili: Radioricevente Rolling-Code incorporata: SEQUENZA DI REGOLAZIONI CONSIGLIATA: -1 10.2) MENU’ LOGICHE (logic) (TABELLA “B” LOGICHE) 10.3) MENU RADIO (RADIO) Logica Agg start Agg 2ch Leggi elim. 64 . cod RX uk 6) INSTALLAZIONE OPERATORE Fig. C 7) Ingresso Cavi Fig. I 8) SBLOCCO MANUALE (Vedi MANUALE D’USO -FIG.1-). ---------------------------------------------------------9) COLLEGAMENTI MORSETTO JP2 JP10 1-2 3-4 Ingresso START / OPEN (N.O.) 3-5 3-6 3-7 8-9 10-11 12-13 14-15 16-17 Ingresso APERTURA PARZIALE / CLOSE (N.O.) 1-3 (SCS-IO) ARGO-ARGO G - 9 TABELLA “A” - MENU PARAMETRI - (PARAM) Logica tca c. ap c. ch min. max. 0 120 40 1 1 ARGO 10 vel. ap ARGO G 18 ARGO 10 ARGO G 18 99 99 99 75 75 99 99 99 5 99 10 10 99 40 Apertura parziale zone 0 129 0 Zona 1 99 50 1 99 50 10 - ARGO-ARGO G D811627 00100_04 D811627 00100_04 min. max. default tca --- --- OFF bl.i p. ap. --- --- OFF Blocca Impulsi 3 Passi --- --- OFF 3 Passi --- --- OFF uomo pres. --- --- OFF Uomo presente OFF Fotocellule in apertura fotoc. ap --- --- --- --- OFF Test fotocellula test bar --- --- OFF Test costa --- --- OFF Master/Slave --- --- OFF aster cod. fisso ON prog. radio --- --- ON --- --- OFF start-open --- --- OFF ped-close --- --- OFF inv. --- --- OFF ot. ARGO-ARGO G - 11 Press the OK key Scroll up Scroll down Control unit software version N. total manoeuvres (in tens) Cancel/return to main menu Confirm/Switch on display param. 1 param. 2 end param. . . . logic logic. 1 logic. 2 end logic. . . . radio add. start hidden button release desired button o 01 Add. 2ch hidden button release desired button o 01 end 01 t1 read PRG. erase 64 +/COD RX 1A9C OK 22FD OK 01 OK v lingua ITA OK - + FRA OK - + end DEU OK - + ENG OK - + esp default OK PRG end (Fig. F) autoset end l.sw adj LIMIT SWITCH ADJUSTMENT end 12 - ARGO-ARGO G Logic PED STRe STOP PHOT BAR CLOS OPEN Suo Suc A P partial opening input activated Set autoset function is running WARNING! Obstacle detection function is not active photocell test error START input activated STOP input activated PHOT input activated SAFETY EDGE input activated CLOSE input activated OPEN input activated opening limit switch activated closing limit switch activated reverse due to obstacle safety edge test error mosfet test error shunt test error encoder test error thermal cutout error optional module communication error 35.40 Set torque threshold % Maximum motor torque % D811627 00100_04 ACCESS TO MENUS D811627 00100_04 INSTALLER WARNINGS WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property. The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference. GENERAL SAFETY This product has been designed and built solely for the purpose indicated herein. Uses other than those indicated herein might cause damage to the product and create a hazard. - The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2004/108/EC, 2006/95/ EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in addition to any national standards in force, to achieve a good level of safety. - The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use. - Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with Good Practice and current code. - Before commencing installation, check the product for damage. - Before installing the product, make all structural changes required to produce safety gaps and to provide protection from or isolate all crushing, shearing and dragging hazard areas and danger zones in general. Check that the existing structure meets the necessary strength and stability requirements. - The Firm is not responsible for failure to apply Good Practice in the construction and maintenance of the doors, gates, etc. to be motorized, or for deformation that might occur during use. - Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed. - Do not install this product in an explosive atmosphere: the presence of flammable fumes or gas constitutes a serious safety hazard. - Disconnect the electricity supply before performing any work on the system. Also disconnect buffer batteries, if any are connected. - Before connecting the power supply, make sure the product’s ratings match the mains ratings and that a suitable residual current circuit breaker and overcurrent protection device have been installed upline from the electrical system. Have the automated system’s mains power supply fitted with a switch or omnipolar thermal-magnetic circuit breaker with a contact separation of at least 3.0mm and any other equipment required by code. - Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A as well as any other equipment required by code. - Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal. - Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453. - Impact forces can be reduced by using deformable edges. - In the event impact forces exceed the values laid down by the relevant standards, apply electro-sensitive or pressure-sensitive devices. - Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazards. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of the system and forces generated by the automated system. - Apply all signs required by current code to identify hazardous areas (residual risks). All installations must be visibly identified in compliance with the provisions of standard EN 13241-1. - This product cannot be installed on leaves incorporating doors (unless the motor can be activated only when the door is closed). - If the automated system is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected. - Install any fixed controls in a position where they will not cause a hazard, away from moving parts. More specifically, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot be reached by the public. - Apply at least one warning light (flashing light) in a visible position, and also attach a Warning sign to the structure. - Attach a label near the operating device, in a permanent fashion, with information on how to operate the automated system’s manual release. - Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more specifically, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding parts. - Once installation is complete, make sure the motor automation settings are correct and that the safety and release systems are working properly. - Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used. - Do not make any modifications to the automated system’s components unless explicitly authorized by the Firm. - Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manually in an emergency. give the user guide to the end user. - Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children. WIRING WARNING! For connection to the mains power supply, use a multicore cable with a cross-sectional area of at least 4x1.5mm2 of the kind provided for by the regulations mentioned above (by way of example, type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm2). To connect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm2. - Only use pushbuttons with a capacity of 10A-250V or more. - Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts. - During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible. The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose. WARNING! safety extra low voltage wires must be kept physically separate from low voltage wires. Only qualified personnel (professional installer) should be allowed to access live parts. CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE Before the automated system is finally put into operation, and during maintenance work, perform the following checks meticulously: - Make sure all components are fastened securely. - Check starting and stopping operations in the case of manual control. - Check the logic for normal or personalized operation. - For sliding gates only: check that the rack and pinion mesh correctly with 2 mm of play; keep the track the gate slides on clean and free of debris at all times. - Check that all safety devices (photocells, safety edges, etc.) are working properly and that the anti-crush safety device is set correctly, making sure that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453. - Make sure that the emergency operation works, where this feature is provided. - Check opening and closing operations with the control devices applied. - Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands are undamaged. - While performing maintenance, clean the photocells’ optics. - When the automated system is out of service for any length of time, activate the emergency release (see “EMERGENCY OPERATION” section) so that the operated part is made idle, thus allowing the gate to be opened and closed manually. SCRAPPING Materials must be disposed of in accordance with the regulations in force. There are no particular hazards or risks involved in scrapping the automated system. For the purpose of recycling, it is best to separate dismantled parts into like materials (electrical parts - copper - aluminium - plastic - etc.). DISMANTLING If the automated system is being dismantled in order to be reassembled at another site, you are required to: - Cut off the power and disconnect the whole electrical system. - Remove the actuator from the base it is mounted on. - Remove all the installation’s components. - See to the replacement of any components that cannot be removed or happen to be damaged. Anything that is not explicitly provided for in the installation manual is not allowed. The operator’s proper operation can only be guaranteed if the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein. While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly. AVVERTENZE PER L’INSTALLATORE D811766_02 ARGO-ARGO G - 13 2) GENERAL INFORMATION Actuator for motorizing residential and industrial sectional doors. Its compact design and mounting versatility mean the drive can be applied in different ways. 3) TECHNICAL SPECIFICATIONS Power supply: 230V ±10%, 50/60Hz (*) Max. power input: 240W Limit switch: Electronic ENCODER model Output shaft MAX. 18 rpm Courtesy light (ARGO): 24V bulb ~ max. 25W, E14 Operating temperature range: Max. door size: ARGO: 20 m2 ARGO G: 35 m2 ARGO: 55 Nm ARGO G: 80 Nm ARGO: 30 min-1 ARGO G: 18 min-1 Lifetime greased Manual operation: Knob-operated mechanical release Protection rating: IP 40 <70dBA Operator weight: 10 kg Dimensions: Accessories power supply: 24V~ (180 mA) Flashing light connection: 24V max 25W Fuses: Built-in Rolling-Code radio-receiver: 9.1) SAFETY DEVICES When using the SCS-IO board with the photocell test feature, the Fault must be connected. Note: only use receiving safety devices with free changeover contact. 1-A: Connection of 1 untested device (photocell or safety edge). Fig. L2-B:Connection of 1 tested device (photocell or safety edge). Fig. L3-C:Connection of 2 tested devices (photocells or safety edges). This connection is made possible via the SCS-IO optional module only. 10) ADJUSTMENTS RECOMMENDED ADJUSTMENT SEQUENCE: Adjusting the limit switches (Fig. E) Autoset (Fig. F) Programming remote controls (Fig. G) Setting of parameters/logic, where necessary 10.1) PARAMETERS MENU (param) (TABLE “A” PARAMETERS) 10.2) LOGIC MENU (logic) (TABLE “B” LOGIC) 10.3) RADIO MENU (RADIO) Logic add start . 5) TUBE ARRANGEMENT Fig. B 6) INSTALLING THE OPERATOR Fig. C 7) Cable entry Fig. I 8) MANUAL RELEASE (See USER GUIDE -FIG. 1-). ---------------------------------------------------------9) WIRING TERMINAL JP2 Transformer wiring JP10 Motor wiring 1-2 Antenna input for built-in radio-receiver board (1:BRAIDING 2: SIGNAL) 3-4 START/OPEN INPUT (N.O.) 3-5 STOP input (N.C.) If not used, leave jumper inserted 3-6 PHOTOCELL input (N.C.) If not used, leave jumper inserted 3-7 SAFETY EDGE input (N.C.) If not used, leave jumper inserted 8-9 24 V~ output for flashing light (max. 25 W) 10-11 24V~ max. 180mA output - power supply to photocells or other devices. 12-13 24V~ Vsafe max. 180mA output - power supply to transmitters photocells with test. 14-15 (NO contact) / Output 1 height programmable 16-17 PARTIAL OPENING/CLOSE input (N.O.) PHOT-FAULT input (NO). Input for photocells equipped with NO test contact. BAR-FAULT input (NO). Input for safety edges equipped with NO test contact. (NO contact) / Output 2 Height programmable Gate open light/2nd radio channel output (NO contact) 14 - ARGO-ARGO G Add Start Key associates the desired key with the Start command add 2ch Add 2ch Key associates the desired key with the 2nd radio channel command read Read Checks a key of a receiver and, if memorized, returns the number of the receiver in the memory location (from 01 to 64) and number of the key (T1-T2-T3 or T4). erase 64 Erase List WARNING! Erases all memorized remote controls from the receiver’s memory. cod RX Read receiver code Displays receiver code required for cloning remote controls. (*) Special supply voltages to order. Usable transmitter versions: All ROLLING CODE transmitters compatible with 4) REMOVING THE COVER Fig. A ON = Enables remote programming of cards via a previously memorizedW LINK transmitter. It remains enabled for 3 minutes from the time the W LINK remote control is last pressed. OFF=W LINK programming disabled. - IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER). In the event of manual programming, the first transmitter assigns the RECEIVER’S KEY CODE: this code is required to subsequently clone the radio transmitters. The Clonix built-in on-board receiver also has a number of important advanced features: • Cloning of master transmitter (rolling code or fixed code) • Cloning to replace transmitters already entered in receiver • Transmitter database management • Receiver community management To use these advanced features, refer to the universal handheld programmer’s instructions and to the CLONIX Programming Guide, which come with the universal handheld programmer device. uk 10.4) LANGUAGE MENU (language) Used to set the programmer’s language on the display. 10.5) DEFAULT MENU (default) Restores the controller’s default factory settings. 10.6) AUTOSET MENU (Autoset) (Fig. F) • Move the door to the closed position. • Launch an autoset operation by going to the relevant menu on the VENERE D panel. • As soon as you press the OK button, the “.... .... ....” message is displayed and the control unit commands the door to perform a full cycle (opening followed by closing), during which the minimum torque value required for the door to move is set automatically. During this stage, it is important to avoid breaking the photocells’ beams and not to use the START and STOP commands or the display. Once this operation is complete, the control unit will have automatically set the optimum torque values. Check them and, where necessary, edit them as described in the programming section. WARNING: Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453. D811627 00100_04 INSTALLATION MANUAL D811627 00100_04 INSTALLATION MANUAL Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s movements and keep people and property out of range of the automated system. 10.7) LIMIT SWITCH ADJUSTMENT MENU (l.sw adj) (fig . E) Limit switch adjustment procedure: 1)Go to L.SW ADJ and confirm with OK. 2) The display reads CLOSE. Use the UP and DOWN keys to move the door to the closing limit switch position. Confirm with OK. The display reads PRG. 3) If prompted by the display, turn the adjustment ring: anticlockwise if the display reads UP; clockwise if the display reads DOWN. Once you have reached the correct position, the display reads OK. Confirm with the OK key. The display reads PRG. 4) The display reads OPEN. Use the UP and DOWN keys to move the door to the opening limit switch position. Confirm with OK. The display reads PRG. If the display reads KO, it means adjustment was not successful. This may be caused by: - the ESC key being pressed before adjustment was completed - stored travel being too short 11) SCS OPTIONAL MODULES 11.1) SERIAL CONNECTION VIA SCS1 CARD (Fig. O) The VENERE D control panel’s special serial inputs and outputs (SCS1) make the centralized connection of a number of automated devices possible. That way, all the automated devices connected can be opened or closed with a single command. Connect all VENERE D control panels using twisted pair cabling only, proceeding as shown in the diagram in Fig. O. When using a telephone cable with more than one pair, it is essential to use wires from the same pair. The length of the telephone cable between one unit and the next must not be greater than 250 m. At this point, each VENERE D control panel needs to be configured appropriately, starting by entering a MASTER control panel that will have control over all the others, which therefore have to be set as SLAVE units (see logic menu). Also set the Zone number (see parameters menu) in the range 0 to 127. The zone number allows you to create groups of automated devices, each of which answers to the Zone Master. Each zone can have only one Master: the Master of zone 0 also controls the Slaves of the other zones. 11.2) Interface with WIEGAND systems via SCS-WIE module. Refer to the SCS-WIE module’s instructions. 11.3) Expanding inputs and outputs via the SCS-IO optional module. The SCS-IO optional module can be used to add 2 inputs and 2 outputs to the VENERE-D board (Fig. D). To activate the connection between SCS-IO and VENERE-D, you need to plug the SCS-IO module into the relevant connector and then set the ZONE parameter to 129. At this point, the 2 boards are synchronized and the SCS-IO board’s inputs/outputs are managed by the VENERE-D board. TABLE “A” - PARAMETERS MENU - (PARAM) Logic min. max. default tca 0 120 op. t 1 cls. t 1 cl speed ARGO 10 ARGO G 18 ARGO 10 ARGO G 18 Definition Description 40 Automatic Closing Time Automatic closing time [s] 99 75 Opening motor torque Opening torque [%] Sets sensitivity to obstacles during opening (1=max., 99=min.) The autoset feature sets this parameter automatically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to obstacles. 99 75 Closing motor torque Closing torque [%] Sets sensitivity to obstacles during closing (1=max., 99=min.) The autoset feature sets this parameter automatically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to obstacles. Speed during opening Running speed during opening [%] Sets the running speed that the door must reach during opening, as a percentage of the maximum speed the actuator can reach. Should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled. 99 99 99 99 Speed during closing Running speed during closing [%] Sets the running speed that the door must reach during closing, as a percentage of the maximum speed the actuator can reach. Should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled. dist.sloud 5 99 10 Slow-down distance Slow-down distance [%] Sets the approach distance to reach the travel limit. This distance is travelled at low speed. partial opening 10 99 40 Partial opening Partial opening [%] Adjusts partial opening percentage compared to total opening in “Partial open” mode. zone 0 129 0 Zone Zone [] Sets the zone number of the door included in the serial connection for commands via central controllers. Zona=128 not used. Zone=129 Use of optional SCS -I0 module. 1 99 50 Output 1 height programmable 1 99 50 Output 2 height programmable The output between terminals 14-15 is activated when the door exceeds the opening percentage set with this parameter (1% = door closed, 99% = door open). The output between terminals 4-5 on the SCS-IO optional module is activated when the door exceeds the opening percentage set with this parameter (1% = door closed, 99% = door open). ARGO-ARGO G - 15 TABLE “B” - LOGIC MENU - (logic) Logic min. max. default Definition ON Switches automatic closing on OFF Switches automatic closing off ON The start pulse has no effect during opening. OFF The start pulse has effect during opening. tca --- --- OFF Automatic Closing Time ibl. open --- --- OFF Block Pulses ON 3 step --- --- OFF 3 Step pre-alar --- --- OFF Pre-alarm hold-to-run --- --- OFF Deadman Switches to 3-step logic. A start pulse has the following effects: door closed: opens during opening: stops and switches on TCA (if configured). door open: closes during closing: stops and opens again OFF Switches to 4-step logic. A start pulse has the following effects: door closed: opens during opening: stops and switches on TCA (if configured) door open: closes during closing: stops and does not switch on tca (stop) ON The flashing light comes on approx. 3 seconds before the motors start. OFF The flashing light comes on at the same time as the motors start ON Deadman mode during closing: opening operation performed in automatic mode; closing operation continues as long as the control key is held down. (CLOSE). OFF Pulse operation (standard) photoc. open --- --- OFF Photocells during opening ON: When beam is broken, operation of the photocell is switched off during opening. During closing, movement is reversed immediately. OFF: When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared. --- --- OFF ON Switches photocell testing on OFF Switches photocell testing off If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not equipped with supplementary test contacts. ON Switches safety edge testing on OFF Switches safety edge testing off If disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not equipped with supplementary test contacts ON Control panel is set up as the Master unit in a centralized connection system. OFF Control panel is set up as a Slave unit in a centralized connection system. test bar aster fixed code --- --- OFF Safety edge testing --- --- OFF Master/Slave --- --- OFF Fixed code ON Receiver is configured for operation in fixed-code mode. OFF Receiver is configured for operation in rolling-code mode. ON Enables wireless memorizing of transmitters: (Fig. K) 1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu. 2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized. The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters. This mode does not require access to the control panel. OFF Disables wireless memorizing of transmitters. Transmitters are memorized only using the relevant Radio menu. radio prog --- --- ON --- --- OFF Gate open light or 2nd radio channel start - open --- --- OFF Selection START - OPEN ON Input between terminals 3-4 works as OPEN. OFF Input between terminals 3-4 works as START ped-close --- --- OFF Selection PEDESTRIAN CLOSE ON Input between terminals 16-17 works as CLOSE. OFF Input between terminals 16-17 works as PEDESTRIAN change --- --- OFF Reversing motion 16 - ot. ARGO-ARGO G ON The output between terminals 6-7 on the optional SCS-10 module is set as Gate open light: in this case, the 2nd radio channel controls pedestrian opening. OFF The output between terminals 6-7 on the optional SCS-10 module is set as 2nd radio channel ON Reverses motion of standard rotation (See Fig.I). OFF Standard rotation (See Fig.I). D811627 00100_04 INSTALLATION MANUAL D811627 00100_04 ACCES AUX MENUS Appuyer sur la touche OK Annuler/revenir au menu principal Confirmation/Allumage afficheur Voir MENU PARAMÈTRES param. 1 param. 2 fin param. . . . logic logic. 1 Voir MENU LOGIQUES logic. 2 fin logic. . . . adj start touche cachee relacher touche desiree o 01 adj 2ch touche cachee relacher touche desiree o 01 radio fin 01 t1 Voir MENU RADIO lire effacer 64 PRG. +/COD RX 1A9C OK 22FD OK 01 OK v langue ITA OK - + FRA PED STRe STOP PHOT BAR CLOS OPEN Suo Suc A P OK - + fin DEU OK - + ENG OK - + esp default OK PRG set fin (Fig. F) autoset RÉGLAGE FIN DE COURSE fin 17 18 - ARGO-ARGO G AVVERTENZE PER L’INSTALLATORE D811766_02 D811627 00100_04 D811627 00100_04 230V ±10%, 50/60Hz (*) 240W Dimensions max. vantail: ARGO: 20 m2 ARGO G: 35 m2 ARGO: 55 Nm ARGO G: 80 Nm ARGO: 30 min-1 ARGO G: 18 min-1 IP 40 Bruit: <70dBA 10 kg Dimensions: 24V~ (180 mA) Branchement clignotant: 24V max 25W 3) CARACTÉRISTIQUES TECHNIQUES SÉQUENCE DE RÉGLAGES CONSEILLÉE: adj start adj 2ch JP2 JP10 1-2 3-4 3-5 3-6 3-7 8-9 10-11 12-13 14-15 16-17 effacer 64 cod RX uk lire . Description 19 min. 0 tca c. ouv c. ferv 1 1 ARGO 10 ARGO G 18 ARGO 10 vit fer ARGO G 18 max. 120 99 99 99 default 40 75 75 99 99 99 Vitesse en fermeture 5 99 10 10 99 40 zone 0 129 0 Zone 1 99 50 1 99 50 20 - ARGO-ARGO G D811627 00100_04 MANUEL D’INSTALLATION D811627 00100_04 min. max. default tca --- --- OFF bl.i p. ouv. --- --- OFF 3 Pas --- --- OFF 3 Pas preal --- --- OFF OFF ho e ort --- --- --- --- OFF --- --- OFF Test photocellule test bar --- --- OFF Test linteau aster --- --- OFF Master/Slave --- --- OFF Code fixe ON code fixe prog. radio --- --- ON ON --- --- OFF start-open --- --- OFF ped-close --- --- OFF --- --- OFF inv. ot. ARGO-ARGO G - 21 param. 1 param. 2 end param. . . . logic logic. 1 logic. 2 end logic. . . . radio verst. taste loslassen gevue. taste o 01 verst. taste loslassen gevue. taste o 01 end 01 t1 lesen PRG. +/COD RX 1A9C OK 22FD OK 01 OK v ITA OK - + FRA OK - + end DEU OK - + ENG OK - + esp default OK PRG Logik PED STRe STOP PHOT BAR CLOS OPEN Suo Suc A P set end autoset (Fig. F) EINSTELLUNG ENDSCHALTER end 22 - ARGO-ARGO G D811627 00100_04 MENÜZUGRIFF D811627 00100_04 AVVERTENZE PER L’INSTALLATORE D811766_02 ARGO-ARGO G - 23 230V ±10%, 50/60Hz (*) 240W Lampe 24V~ max. 25W, E14 Betriebstemperatur: ARGO: 20 mq ARGO G: 35 mq ARGO: 55 Nm ARGO G: 80 Nm ARGO: 30 min-1 ARGO G: 18 min-1 Manuelles Manöver: IP 40 <70dBA 10 kg Fig. H 24V~ (180 mA) 24V max 25W Fig. D cod RX JP2 Verkabelung Transformator JP10 Verkabelung Motor 1-2 3-4 3-5 3-6 3-7 8-9 10-11 12-13 14-15 16-17 Eingang PARTIELLE ÖFFNUNG / SCHLIESSEN (N.O.) 24 - uk D811627 00100_04 MONTAGEANLEITUNG D811627 00100_04 TABELLE “A” - MENÜ PARAMETER - (PARAM) Logik tca d. auf d. zu min. 0 1 1 ARGO 10 ARGO G 18 ARGO 10 ARGO G 18 max. 120 99 99 99 default Definition 40 75 75 99 99 99 dist.sloud 5 99 10 Raum Verlangsamung 10 99 40 zone 0 129 0 1 99 50 1 99 50 25 TABELLE “B” - MENÜ LOGIKEN (logic) Logik min. max. default Definition tca --- --- OFF impulsbl. auf --- --- OFF Impulse blockieren --- --- OFF voralar --- --- OFF Voralarm tot ann --- --- OFF OFF Test Fotozelle ON fotoz. auf test bar aster fest code --- --- --- --- OFF --- --- OFF --- --- OFF Master/Slave --- --- OFF prog. func --- --- ON --- --- OFF start-open --- --- OFF ped-close --- --- OFF ot. taush --- --- OFF 26 - ARGO-ARGO G ON D811627 00100_04 MONTAGEANLEITUNG D811627 00100_04 Cancelar / retorno al menú principal param. 1 param. 2 fine param. . . . logic logic. 1 logic. 2 fine logic. . . . radio anad start tecla escond suelte o 01 anad 2ch tecla escond suelte o 01 Leer PRG. canc 64 +/COD RX 1A9C OK 22FD OK 01 OK v ITA OK - + FRA OK - + fine DEU OK - + ENG OK - + default OK PRG PED STRe STOP PHOT BAR CLOS OPEN Suo Suc A P (Fig. F) fine REGULACIÓN DE LOS FINALES DE CARRERA fine esp 35.40 Umbral de par configurado % Par máximo motor % ARGO-ARGO G - 27 28 - ARGO-ARGO G AVVERTENZE PER L’INSTALLATORE D811766_02 D811627 00100_04 ADVERTENCIAS PARA LA INSTALACIÓN D811627 00100_04 230V ±10%, 50/60Hz (*) Máx. potencia absorbida: 240W Máx. Dimensiones hoja: ARGO: 20mq ARGO G: 35mq 10.1) MENÚ PARÁMETROS (param) (TABLA “A” PARÁMETROS) ARGO: 55Nm ARGO G: 80Nm 10.2) MENÚ LÓGICAS (logic) (TABLA “B” LÓGICAS) ARGO: 30 min-1 ARGO G: 18 min-1 10.3) MENU RADIO (RADIO) Grasa permanente IP 40 <70dBA Peso operador: 10 kg Dimensiones: Véase Fig. H 24V~ (180 mA) 24V max 25W Fusibili: Véase Fig. D . 5) DISPOSICIÓN DE TUBOS Fig. B 6) INSTALACIÓN OPERADOR Fig. C 7) Entraa cables Fig. I 8) DESBLOQUEO MANUAL (Véase MANUAL DE USO -Fig. 1-). ---------------------------------------------------------9) CONEXIONES BORNE JP2 JP10 1-2 3-4 Entrada START / OPEN (N.O.) 3-5 3-6 3-7 8-9 Salida 24 V~ para indicador parpadeante (25 W máx.) 10-11 12-13 14-15 16-17 Entrada APERTURA PARCIAL / CLOSE (N.O.) Entrada FAULT-PHOT (NO). Entrada para fotocél. con contacto N.O. de control. 4-5(SCS-IO) 29 TABLA “A” - MENÚ PARÁMETROS - (PARAM) Lógica tca min. máx 0 120 40 1 p. apert 1 99 99 75 75 ARGO 10 99 99 ARGO 18 Par motores apertura 99 99 5 99 10 apert.parcial 10 99 40 zone 0 129 0 Zona 1 99 50 1 99 50 30 - ARGO-ARGO G D811627 00100_04 MANUAL DE INSTALACIÓN D811627 00100_04 MANUAL DE INSTALACIÓN min. máx. default tca --- --- OFF bl.i p. ap. --- --- OFF Bloquea Impulsos 3 Pasos --- --- OFF 3 Pasos prealar a --- --- OFF Prealarma ho bre pres --- --- OFF fotoc.ap. --- --- OFF --- --- OFF Prueba de fotocélula test bar --- --- OFF aster --- --- OFF Master/Slave cod. fijo --- --- OFF Código Fijo prog. radio --- --- ON --- --- OFF start - open --- --- OFF ped-close --- --- OFF inv. --- --- OFF ot. ON ARGO-ARGO G - 31 Doorloop op Doorloop neer Versie software centrale param. 1 param. 2 end param. . . . logic logic. 1 logic. 2 end logic. . . . radio add. start hidden button release desired button o 01 Add. 2ch hidden button release desired button o 01 end 01 t1 read PRG. erase 64 +/COD RX 1A9C OK 22FD OK 01 OK v language ITA OK - + FRA OK - + end DEU OK - + ENG OK - + esp default OK PRG Logic Description PED STRe STOP PHOT BAR CLOS OPEN Suo Suc A P partial opening input activated set end autoset (Fig. F) end l.sw adj REGELING EINDAANSLAGEN end 32 - ARGO-ARGO G START input activated STOP input activated PHOT input activated SAFETY EDGE input activated CLOSE input activated OPEN input activated opening limit switch activated closing limit switch activated reverse due to obstacle zelfinstelling OPGELET! Functie van opname hindernissen niet actief photocell test error safety edge test error mosfet test error shunt test error encoder test error thermal cutout error optional module communication error 35.40 Set torque threshold % Maximum motor torque % D811627 00100_04 D811627 00100_04 AVVERTENZE PER L’INSTALLATORE D811766_02 ARGO-ARGO G - 33 NEDERLANDS 230V ±10%, 50/60Hz (*) 240W Eindaanslag: Elektronisch met ENCODER MAX 18 toeren Uitgangsas Waaklicht (ARGO): Lamp 24V~ 25W max, E14 Max afmetingen luik: ARGO: 20 mq ARGO G: 35 mq Max koppel: ARGO: 55 Nm ARGO G: 80 Nm ARGO: 30 min-1 ARGO G: 18 min-1 Smering: Mechanische deblokkering met knop IP 40 Lawaai: <70dBA Gewicht operator: 10 kg Afmetingen: 24V~ (180 mA) 24V max 25W 3) TECHNISCHE GEGEVENS (*) Speciale voedingsspanningen op aanvraag. Versies bruikbare transmitters: Alle transmitters ROLLING CODE compatibel met 10.1) MENU PARAMETERS (param) (TABEL “A” PARAMETERS) 10.2) MENU’S LOGICA’S (logic) (TABEL “B” LOGICA) Agg start Agg 2ch Leggi . 6) INSTALLATIE OPERATOR Fig. C 7) Ingang kabels Fig. I 8) MANUELE DEBLOKKERING (Zie GEBRUIKSHANDLEIDING -Fig. 1-). ---------------------------------------------------------9) VERBINDINGEN BESCHRIJVING Bekabeling transformateur JP10 Bekabeling motor 1-2 3-4 Ingang START / OPEN (N.O.) 3-5 Ingang STOP (N.C.) Indien niet gebruikt de brug ingevoerd laten. 3-6 Ingang FOTOCEL (N.C.) Indien niet gebruikt de brug ingevoerd laten. 3-7 Ingang BOORD (N.C.) Indien niet gebruikt de brug ingevoerd laten. 8-9 10-11 Uitgang 24V~180mA max-Voeding fotocellen of andere inrichtingen. 12-13 Uitgang24V~Vsafe 180mA max-Voeding transmitters fotocell. met nazicht. 14-15 16-17 Ingang GEDEELTELIJKE OPENING / CLOSE (N.O.) 34 - ARGO-ARGO G elim. 64 JP2 10.3) MENU RADIO (RADIO) Logica KLEM Regeling van de eindaanslagen (Fig. E) Autoset (Fig. F) Programmering afstandsbediening (Fig. G) Eventuele regelingen van de parameters / logica’s D811627 00100_04 MONTAJ KILAVUZU D811627 00100_04 TABEL “A” - MENU PARAMETERS - (PARAM) min. max. default tca 0 120 40 Tijd Automatische Sluiting op. t 1 99 75 Koppel motoren opening cls. t 1 99 75 Koppel motoren sluiting Snelheid in opening ARGO 10 99 op speed 99 ARGO G 18 99 99 Snelheid in sluiting ARGO 10 cl speed ARGO G 18 dist. sloud 5 99 10 Ruimte vertraging partial opening 10 99 40 zone 0 129 0 Zone 1 99 50 Uitgang 1 programmeerbaar in de hoogte 1 99 50 Uitgang 2 programmeerbaar in de hoogte 35 min. max. default tca --- --- OFF ibl. open --- --- OFF Blokkeer impulsen 3 step --- --- OFF 3 Stappen pre-alar --- --- OFF Prealarm hold-to-run --- --- OFF photoc. open test bar aster fixed code --- --- --- --- OFF OFF Test fotocel --- --- OFF Test boord --- --- OFF Master / Slave --- --- OFF Vaste Code radio prog --- --- ON Programmering afstandsbedieningen --- --- OFF Seinlamp hek open of II° radiokanaal start - open --- --- OFF Selectie START - OPEN ped-close --- --- OFF Selectie VOETGANGERS CLOSE change ot. --- --- OFF Omkering van de beweging ON Keert de beweging van de standaard rotatie om (Zie Fig.I). OFF Standaard rotatie (Zie Fig.I). 36 - ARGO-ARGO G D811627 00100_04 MONTAJ KILAVUZU D811627 00100_04 FIG.1 MANUALE D’USO: MANOVRA MANUALE - USER’S MANUAL: MANUAL OPERATIONMANUEL D’UTILISATION: MANŒUVRE MANUELLE - BEDIENUNGSANLEITUNG: MANUELLES MANÖVERMANUAL DE USO: ACCIONAMIENTO MANUAL - GEBRUIKSHANDLEIDING: MANUEEL MANOEUVRE ARGO A C B Se le porte non sono correttamente bilanciate e l’apertura/chiusura, risultano perticolarmente difficoltose, è necessario utilizzare lo sblocco di emergenza RCA/RCAL. If doors are not correctly balanced and opening/closing is especially difficult, use the RCA/RCAL emergency release. Si les portes ne sont pas équilibrées correctement et que l’ouverture et/ou la fermeture s’avèrent particulièrement difficiles, utilisez le déverrouillage d’urgence RCA/RCAL. Falls die Türen nicht korrekt ausgewogen sind und das Öffnen/Schließen Schwierigkeiten bereitet, muss die Notfallentsperrung RCA/RCAL verwendet werden. Si las puertas no están correctamente balanceadas y las fases de apertura/cierre son demasiado dificultosas, es necesario utilizar el desbloqueo de emergencia RCA/RCAL. Se as portas não estiverem correctamente equilibradas e a abertura/fecho, forem particularmente dificultosos, é necessário utilizar o desbloqueio de emergência RCA/RCAL. ARGO G Usare SEMPRE lo sblocco di emergenza RCA/RCAL. ALWAYS use the RCA/RCAL emergency release. Utilisez TOUJOURS le déverrouillage d’urgence RCA/RCAL. Verwenden Sie IMMER die Notfallentsperrung RCA/RCAL . Usar SIEMPRE el desbloqueo de emergencia RCA/RCAL. ALTIJD de RCA/RCAL -nooddeblokkering gebruiken. ARGO-ARGO G - 37 USER WARNINGS (GB) WARNING! Important safety instructions. Carefully read and comply with the Warnings and Instructions that come with the product as improper use can cause injury to people and animals and damage to property. Keep the instructions for future reference and hand them on to any new users. This product is meant to be used only for the purpose for which it was explicitly installed. Any other use constitutes improper use and, consequently, is hazardous. The manufacturer cannot be held liable for any damage as a result of improper, incorrect or unreasonable use. GENERAL SAFETY Thank you for choosing this product. The Firm is confident that its performance will meet your operating needs. This product meets recognized technical standards and complies with safety provisions when installed correctly by qualified, expert personnel (professional installer). If installed and used correctly, the automated system will meet operating safety standards. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided: -Keep adults, children and property out of range of the automated system, especially while it is moving. -Do not allow children to play or stand within range of the automated system. -This automated system is not meant for use by children or by people with impaired mental, physical or sensory capacities, or people who do not have suitable knowledge. -Do not work near hinges or moving mechanical parts. -Do not hinder the leaf’s movement and do not attempt to open the door manually unless the actuator has been released with the relevant release knob. -Keep out of range of the motorized door or gate while they are moving. -Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently. -The manual release’s activation could result in uncontrolled door movements if there are mechanical faults or loss of balance. -When using roller shutter openers: keep an eye on the roller shutter while it is moving and keep people away until it has closed completely. Exercise care when activating the release, if such a device is fitted, as an open shutter could drop quickly in the event of wear or breakage. - The breakage or wear of any mechanical parts of the door (operated part), such as cables, springs, supports, hinges, guides…, may generate a hazard. Have the system checked by qualified, expert personnel (professional installer) at regular intervals according to the instructions issued by the installer or manufacturer of the door. -When cleaning the outside, always cut off mains power. -Keep the photocells’ optics and illuminating indicator devices clean. Check that no branches or shrubs interfere with the safety devices. -Do not use the automated system if it is in need of repair. In the event the automated system 38 - ARGO-ARGO G breaks down or malfunctions, cut off mains power to the system; do not attempt to repair or perform any other work to rectify the fault yourself and instead call in qualified, expert personnel (professional installer) to perform the necessary repairs or maintenance. To allow access, activate the emergency release (where fitted). -If any part of the automated system requires direct work of any kind that is not contemplated herein, employ the services of qualified, expert personnel (professional installer). -At least once a year, have the automated system, and especially all safety devices, checked by qualified, expert personnel (professional installer) to make sure that it is undamaged and working properly. -A record must be made of any installation, maintenance and repair work and the relevant documentation kept and made available to the user on request. - Failure to comply with the above may result in hazardous situations. D811627 00100_04 AVVERTENZE PER L’UTILIZZATORE ( I ) Anything that is not explicitly provided for in the user guide is not allowed. The operator’s proper operation can only be guaranteed if the instructions given herein are complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein. While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly. ADVERTENCIAS PARA EL USUARIO (E)">
/
Letöltés
Csak egy baráti emlékeztető. A dokumentumot itt is megtekintheti. De ami a legfontosabb, a mi AI-nk már elolvasta. Egyszerűen el tudja magyarázni a bonyolult dolgokat, bármilyen nyelven megválaszolja kérdéseit, és segít gyorsan navigálni a leghosszabb vagy legbonyolultabb dokumentumokban is.
Hirdetés