- No category
advertisement
▼
Scroll to page 2
of 23
Thermozone AD Corinte W - ADCS SE ...20 GB ...23 NO ...26 FR ...29 RU ...32 DE ...35 NL ...38 ES ...41 PL ...44 FI ...47 IT ...50 DK ...53 2 Fig 1 Min 180 225 116 72 M8 Bottom (seen from above) Top Wall VL - B VL - A Doorway VR - B VR - A Bottom (seen from above) M8 Top Wall 116 72 Min 180 225 Cu ø22 Thermozone AD Corinte W - ADCS 125 125 Fig 2 2200/2450 500 350 Fig 3 2 1 2 Ø22 Cu Ø22 Cu 3 1 80 60 PH2 / 1/4” 60 80 Thermozone AD Corinte W - ADCS 3 Thermozone AD Corinte W - ADCS 6 3 1 2 B C A 5 7 10 9 4 Fig 4 4 8 Thermozone AD Corinte W - ADCS Fig 5 5 Thermozone AD Corinte W - ADCS 1700/2200 75 1670/2170 Wall Right connection 100 126 Left connection Ø31.5 (2x) Ø20 (3x) Fig 6a 75 376 Fig 6b 6 Thermozone AD Corinte W - ADCS 35 80 180 35 ø1 2 25 40 Fig 6c Fig 6d 360 0 Ø22 5 15 10 243 Ø1 Fig 7 7 Thermozone AD Corinte W - ADCS ADCEH Ø8 Ø12 (2x) } 2 alternatives for securing at the top.*1 A B C Ø8 for securing at the air curtain.*2 A B C SE / NO / FR / RU / DE / NL / ES / PL / FI / IT / DK *1) 2 alt. för stagning i toppen. / 2 muligheter for montering på toppen. / 2 possibilités de fixation par le haut. / 2 варианта крепления верхней части / Zwei Befestigungsmöglichkeiten an der Oberseite / 2 alternatieven voor bevestiging aan de bovenkant. / 2 opciones de sujeción a la parte superior. / 2 opcje montażu w części górnej. / 2 vaihtoehtoista kiinnitystapaa. / 2 alternative per il montaggio sulla parte superiore. / 2 alternativer til fastgørelse foroven. *2) Ø8 för stagning i luftridån. / Ø8 for montering på luftporten. / Ø8 pour fixation du rideau d’air. / Для крепления к завесе / Ø 8 zur Befestigung am Luftschleier / Ø8 voor bevestiging aan het luchtgordijn. / Ø8 para sujeción a la cortina de aire. / Ø8 do zamocowania kurtyny powietrznej. / Ø8 ilmaverhokojeen kiinnitykseen. / Ø8 per il montaggio sulla barriera d’aria. / Ø8 til fastgørelse af lufttæppet. 8 Thermozone AD Corinte W - ADCS ADCS - SIRe Fig 8 SIRe 9 Thermozone AD Corinte W - ADCS Regulations alternatives This aircurtain is supplied with an intelligent and well designed low voltage control system SIRe which can be customized for each unique application and environment. The control system is pre-installed in the aircurtain with an integrated control card. Type SIReB SIReAC SIReAA SIReRTX SIReUR* SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 SIReCC615 SIReCC403 SIReCC405 SIReCC410 SIReCC415 RSK-nr 673 09 22 673 09 21 673 09 23 673 09 24 673 09 25 673 09 26 673 09 27 673 09 28 673 09 29 673 09 30 SIRe is supplied pre-programmed with quickrelease connections and is very easy to use and install. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Description Control system Basic Control system Competent Control system Advanced External room temperature sensor Kit for recessed installation Clamp-on sensor Joint piece for two pcs. RJ11 (4p/4c) Joint piece for two pcs. RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (4p/4c) Modular cable RJ11 (4p/4c) Modular cable RJ11 (4p/4c) Modular cable RJ11 (4p/4c) HxWxD [mm] L [m] 70x33x23 114x70x50 3 5 10 15 3 5 10 15 Water regulation Type Description VOS15LF VOS15NF VOS20 VOS25 VOSP15LF VOSP15NF VOSP20 VOSP25 VMO15LF VMO15NF VMO20 VMO25 VMOP15LF VMOP15NF VMOP20 VMOP25 VOT15 VOT20 VOT25 VMT15 VMT20 VMT25 VAT Valve kit on/off Valve kit on/off Valve kit on/off Valve kit on/off Pressure independent valve kit Pressure independent valve kit Pressure independent valve kit Pressure independent valve kit Modulating valve kit Modulating valve kit Modulating valve kit Modulating valve kit Pressure independent and modulating valve kit Pressure independent and modulating valve kit Pressure independent and modulating valve kit Pressure independent and modulating valve kit Three way valve and actuator on/off Three way valve and actuator on/off Three way valve and actuator on/off Three way valve and modulating actuator Three way valve and modulating actuator Three way valve and modulating actuator Adjustment tool for valve kit VOS, VOSP, VMO, VMOP 10 Voltage [V] 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 230 V 230 V 230 V 24 V 24 V 24 V Thermozone AD Corinte W - ADCS Wiring diagrams Internal wiring diagram ADCS W 230V~ SIReB1 C2 Internal Motor sensor protection Yellow Orange Red Brown Black Green Blue 230V 200V 170V 145V 120V 100V N Transformer ROOM Transformer C1 230V 200V 170V 145V 120V 100V N Blue Actuator 230V~ Black Supply 230V~ N L 230V~ 11 Thermozone AD Corinte W - ADCS Wiring diagrams Basic SIReB1 SIReRTX (optional) SD230 Basic - parallell SIReB1 SIReB1 SIReB1 12 SD230 SD230 SD230 SIReRTX (optional) SIReRTX (optional) Thermozone AD Corinte W - ADCS Competent 13 14 SIReB1 SIReB1 SIReB1 SD230 SD230 SD230 SIReC1X (optional) Thermozone AD Corinte W - ADCS Competent - parallell SIReB1 SIReWTA (optional) SIReA1X SIReRTX (optional) Thermozone AD Corinte W - ADCS Advanced 15 16 SIReB1 SIReB1 SIReB1 SIReWTA (optional) SDM24 SDM24 SDM24 ST23024 ST23024 ST23024 SIReA1X SIReRTX (optional) Thermozone AD Corinte W - ADCS Advanced - parallell Thermozone AD Corinte W - ADCS AD Corinte W - ADCS Low temperature coil Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 In- / outlet water temperature 70/40 °C Inlet air temp. +15 °C Incoming air temp. +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow flow position out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] max 3000 21.8 36 0.17 18.5 38 0.14 min 1400 13.5 43 0.10 11.5 44 0.09 max 4000 30.7 37 0.24 26.2 39 0.20 min 1800 18.4 45 0.14 15.8 45 0.12 max 4500 35.1 38 0.27 30.0 39 0.23 min 2050 21.2 45 0.16 18.2 46 0.14 Incoming / outgoing water temperature 60/40 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output flow flow position out out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] max 3000 19.4 34 0.23 16.2 36 0.19 min 1400 12.0 40 0.14 10.1 41 0.12 max 4000 27.0 35 0.32 22.8 37 0.27 min 1800 16.1 41 0.19 13.7 42 0.16 max 4500 30.8 35 0.36 26.0 37 0.31 min 2050 18.5 42 0.22 15.7 43 0.18 Incoming / outgoing water temperature 60/30 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 14.4 29 0.11 10.9 31 0.08 min 1400 9.2 34 0.07 7.1 35 0.05 max 4000 20.7 30 0.16 15.9 32 0.12 min 1800 12.8 36 0.10 10.0 36 0.07 max 4500 23.8 31 0.18 18.5 32 0.14 min 2050 14.8 36 0.11 11.6 37 0.09 Incoming / outgoing water temperature 55/35 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 16.1 31 0.19 12.9 33 0.15 min 1400 10.0 36 0.11 8.1 37 0.09 max 4000 22.6 32 0.27 18.2 33 0.21 min 1800 13.6 37 0.16 11.1 38 0.13 max 4500 25.9 32 0.30 21.0 34 0.25 min 2050 15.7 38 0.18 12.8 38 0.15 17 Thermozone AD Corinte W - ADCS AD Corinte W - ADCS High temperature coil In- / outlet water temperature 130/65 °C Inlet air temp. +15 °C Incoming air temp. +20 °C Air temp. Water Output Air temp. Water Type Fan Airflow Output out flow flow position out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] ADCS17 max 3000 30.8 45 0.11 28.6 48 0.10 min 1400 20.0 57 0.07 18.6 59 0.06 ADCS22 max 4000 42.8 46 0.15 39.7 49 0.14 min 1800 27.1 59 0.09 25.2 61 0.09 ADCS25 max 4500 48.8 47 0.17 45.3 49 0.16 min 2050 31.1 59 0.11 29.0 61 0.10 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 18 Incoming / outgoing water temperature 90/70 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output flow flow position out out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] max 3000 26.4 40 0.31 24.3 43 0.28 min 1400 16.8 50 0.20 15.4 52 0.18 max 4000 36.0 41 0.43 33.1 44 0.39 min 1800 22.3 51 0.26 20.6 53 0.24 max 4500 40.8 41 0.48 37.6 44 0.44 min 2050 25.5 51 0.30 23.5 53 0.28 Incoming / outgoing water temperature 82/71 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 25.4 40 0.55 23.3 42 0.50 min 1400 16.0 48 0.34 14.7 51 0.31 max 4000 34.5 40 0.74 31.7 43 0.68 min 1800 21.2 49 0.46 19.5 51 0.42 max 4500 39.1 40 0.84 35.9 43 0.77 min 2050 24.2 49 0.52 22.2 52 0.48 Incoming / outgoing water temperature 80/60 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 22.0 36 0.26 19.9 39 0.23 min 1400 14.0 44 0.16 12.7 46 0.15 max 4000 30.1 37 0.35 27.3 40 0.32 min 1800 18.7 45 0.22 17.0 47 0.20 max 4500 34.2 37 0.40 31.0 40 0.36 min 2050 21.4 45 0.25 19.4 47 0.23 Thermozone AD Corinte W - ADCS Technical specifications | Thermozone AD Corinte WL with water heat, coil for low tempered water < 80/60 °C 2 Type Output*4 Airflow ∆t*3,4 Water Sound Output Voltage volume level*5 motor motor [kW] 33 46 52 [°C] 42/32 43/33 43/34 [l] 2,8 3,6 4,0 [m3/h] 1400/3000 1800/4000 2050/4500 [dB(A)] 39/59 42/60 42/61 [W] 670 990 1150 [V] 230V~ 230V~ 230V~ Amperage Length Weight motor [A] 2,9 4,3 5,0 [mm] 1700 2200 2450 [kg] 85 110 125 Technical specifications | Thermozone AD Corinte WH with water heat, coil for high tempered water ≥80/60 °C 2 Type Output*4 Airflow [kW] 1 ADCS17WH* 22 ADCS22WH 30 ADCS25WH*2 34 [m3/h] 1400/3000 1800/4000 2050/4500 ∆t*3,4 Water Sound volume level*5 [°C] 30/22 31/22 31/22 [l] 2,8 3,6 4,0 [dB(A)] 39/59 42/60 42/61 Output Voltage Amperage Length Weight motor motor motor [W] 670 990 1150 [V] 230V~ 230V~ 230V~ [A] 2,9 4,3 5,0 [mm] 1700 2200 2450 [kg] 85 110 125 *1) ADCS17 is available only for horizontal mounting. *2) ADCS25 is available only for vertical mounting. *3) Applicable at water temperature 80/60 °C, air temperature in + 15 °C. *4) Dt= temperature rise of passing air at maximum heat output and lowest/highest airflow. *5) Conditions: Distance to the unit: 5 metres. Directional factor: 2. Equivalent absorption area: 200 m2. Protection class: IP20. CE compliant. 19 Thermozone AD Corinte W - ADCS DE 35 DE Thermozone AD Corinte W - ADCS DE 37 Tel: +46 31 336 86 00 Fax: +46 31 26 28 25 [email protected] www.frico.se For latest updated information and information about your local contact: www.frico.se Main office Frico AB Box 102 SE-433 22 Partille Sweden
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project