I D811224 06-06-98 Ver. 01 CENTRALINA DI COMANDO GB CONTROL UNIT F UNITÉ DE COMMANDE D E CENTRAL DE MANDO ELMEC2 ISTRUZIONI INSTRUCTIONS INSTRUCTIONS MONTAGEANLEITUNG INSTRUCCIONES BFT U.K. SWIFT Automation Ltd Hindley Street, Stockport SK1 3LF England Tel. 0 161 480 6677 Fax. 0 161 477 6675 BFT Parc Club des Aygalades 35 bd capitaine GEZE 13333 MARSEILLE Cedex 14 Tel. Fax 04 91.98.13.82 04 91.98.11.27 BFT BERMATIC BFT S.L. Poligono GARONA NAVE Q 19200 AZUQUECA DE HENARES (GUADALAJARA) Tel. 949/263200 Fax 949/262451 BFT S.r.l. ITALIA I GB Thank you for buying this product, our company is sure that you will be more than satisfied with the product’s performance. The product is supplied an “INSTRUCTION MANUAL” which provides important information about safety, installation, operation and maintenance. This product complies with the recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 89/336/EEC and 73/23/EEC (amended by RL 91/263/EEC, 92/31/EEC and 93/68/EEC). IMPORTANT NOTE For wiring and installation operations, refer to the current standards and follow the main technical principles ensuring good performance. 400V±10% 50Hz. > 2MOhm 500Vdc 3750Vac per 1 minuto 0.05A max 24Vac 8VA max 1.6A 750W contatto N.C. 183x225x120 -20/+55 °C 2 - ELMEC2 1) General outline The ELMEC2 control unit has been designed to control one three-phase motor with a power up to 750 W. The control unit is equipped with Dip-FIX which allow configuration of the unit. The functions of the Dip-FIX are described in the following paragraphs while the connection to the terminals is shown in the diagram of fig. 1. 2) Technical specifications Three-phase main power supply Mains insulation/low voltage Dielectric strength/low voltage No-load current Power supply to accessories Relay max current Max power absorbed by motor Limit switches Control board dimensions Working temperature 400V±10% 50Hz. > 2MOhm 500Vdc 3750Vac per 1 minute 0.05A max 24Vac 8VA max 1.6A 750W N.C. contact 183x225x120 -20/+55 °C 3) Terminal board connection JP1 1-2-3 Three-phase power supply: 400V ±10% 50/60 Hz. WARNING: break the line upstream and fit three 2A fuses. 4-5-6 Motor connections JP3 7 Common wire 7-8 STOP push button (N.C.). If not used, leave jumped. 7-9 Opening limit switch (SWO) 7-10 Closing limit switch (SWC) 9-11 Opening push button 10-12 Closing push button 13-14 Output 24Vac 0.3A max (8VA) JP4 (on request) 15-16 Antenna (15 signal, 16 braid) JP2 17-18 WARNING: Mains current to terminals EMERGENCY push button (N.C.). Use a stop hold-to-run push button and two N.C. contacts having at least 8 mm air distance. If not used, leave jumped. JP5 (on request). 1-2 channel receiver connector. Channel 1 - Opens Channel 2 - Closes DIP-FIX J1 ON Automatic closing control. OFF Hold-to-run closing control. DIP-FIX J2 ON Automatic opening control. OFF Hold-to-run opening control. F D 400V±10% 50Hz (triphasé). > 2MOhm 500Vdc 3750Vac pendant 1 minute 0,05A maxi 24Vac 8VA maxi 1,6A 750W contact N.F. 183x225x120 -20/+55 °C 400 V±10% 50Hz. > 2MOhm 500Vdc 3750Vac pro Minute 0.05A max 24Vac 8VA max 1,6 A 750W Ruhekontakt (N.C.) 183x225x120 -20/+55 °C ELMEC2 - 3 T1 Cavallotto di messa a terra U-link for earth connection Crampillon de mise à la terre Erdanschlussklemmen Perno de U de toma de tierra La centralina viene fornita completa di cablaggi e pulsanti su coperchio di OPEN - CLOSE - STOP. The control unit is supplied with cables and OPEN - CLOSE - STOP push buttons on the cover. La centrale est fournie équipée de câblage et de boutons sur le couvercle de OPEN - CLOSE - STOP. Die Steuerung wird komplett mit verkabelten OPEN - CLOSE - STOP Taster geliefert. La central se suministra provista de cableados y botones en la tapa de OPEN - CLOSE - STOP. Fig.1 4 - ELMEC2 K4 F1 K1 JP4 K3 ELMEC2 OFF Open D. M. ON Open J2 J2 J1 J1 JP2 JP3 3 4 5 6 7 T M JP2 17 18 STOP JP4 15 16 ANT. Disponibilità di raccordi tubo - cassetta: CRTR (raccordo con tubo rigido) CRTL (raccordo con guaina flessibile) Available couplings connecting the pipes to the box: CRTR (coupling with rigid pipe) CRTL (coupling with flexible sheath) Disponibilité de raccords tube - boîte: CRTR (raccord avec tube rigide) CRTL (raccord avec tuyau souple) Erhältliche Rohrverschraubungen für Steuerungsgehäuse: CRTR (Verbindungsstück für starres Rohr) CRTL (Verbindungsstück für flexibles Rohr) Disponibilidad de uniones tubo - caja: CRTR (unión con tubo rígido) CRTL (unión con vaina flexible) 6 7 8 9 9 10 11 12 13 14 10 11 12 13 14 SWC S 5 SWO R 4 COM 3 2 STOP 1 8 JP3 JP1 OPEN 2 CLOSE 1 24Vac NO NO NC NC NC EMERGENCY 18 K1 400V±10% 50Hz. > 2MOhm 500Vdc. 3.750Vac por 1 minuto. 0,05A máx. 24Vac 8VA máx. 1,6A 750W contacto N.C. 183x225x120 -20/+55 °C 17 JP1 230V T 0.1A JP5 DL1 Dip-Fix: ON Dip-Fix: OFF ELMEC2 OP ST E OS CL EN OP">
/
Atsisiųsti
Tiesiog draugiškas priminimas. Dokumentą galite peržiūrėti tiesiog čia. Bet svarbiausia, kad mūsų AI jau jį perskaitė. Jis gali paaiškinti sudėtingus dalykus paprastais terminais, atsakyti į jūsų klausimus bet kuria kalba ir padėti greitai naršyti net ilgiausius ar sudėtingiausius dokumentus.
Reklama