INSTALLATION MANUAL
Thank you for buying this product, our company is sure that you will
be more than satisfied with the product’s performance. The product is
supplied with a “Warnings” leaflet and an “Instruction booklet”. These
should both be read carefully as they provide important information about
safety, installation, operation and maintenance. This product complies with
the recognised technical standards and safety regulations. We declare
that this product is in conformity with the following European Directives:
89/336/EEC and 73/23/EEC (and subsequent amendments).
3.2) Recessed mounting on metal pillar (SELETTO)
Make a hole by means of a ø 60 milling cutter where the supplied plastic
container is to be inserted. To fix the container, drill three ø 3.6 holes
for the three self-tapping screws.
3.3) External container mounting (SELETTO E)
Use the box as a drilling template and drill 4 holes. Fix by means of
self-tapping screws or expansion plugs, depending on the surface the
box is being fixed on. (Fig. 1b).
GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
•
Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon
or polystyrene bags out of children’s reach.
•
Keep the instructions together with the technical brochure for future
reference.
•
This product was exclusively designed and manufactured for the
use specified in the present documentation. Any other use not
specified in this documentation could damage the product and be
dangerous.
•
The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is different
from that expected and specified in the present documentation.
•
Do not install the product in explosive atmosphere.
•
Disconnect the electrical power supply before carrying out any work
on the installation. Also disconnect any buffer batteries, if fitted.
•
Only use original parts for any maintenance or repair operation.
•
Instruct the product user about the control systems provided and
the manual opening operation in case of emergency.
•
Do not allow persons or children to remain in the automation operation
area.
•
Keep radio control or other control devices out of children’s reach,
in order to avoid unintentional automation activation.
•
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
•
Anything which is not expressly provided for in the present instructions, is not allowed.
•
Fit an omnipolar or magnetothermal switch on the mains power
supply, having a contact opening distance equal to or greater than
3,5 mm.
•
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
The subsequent phases are identical for all types of mounting:
1) Proceed to wiring and fixing the electronic board by means of the 2
screws supplied as standard, as shown in Fig. 2-”A”. Fully tighten the
screws, and correct any centring errors using the slots in the board.
Correct board positioning is obtained by means of the connection
terminal bar, positioned as shown in Fig. 2-”A”.
2) Position the gasket and metal ring nut, as shown in Fig. 2-”B”,
and proceed to fixing using the 3 screws supplied. Ensure that the
gasket and ring nut are correctly positioned, the ring nut must have
its anti-break-in dowel positioned as shown in Fig. 2-”C”.
3) Attach the metal button unit after rotating it by about 30° anticlockwise,
as shown in Fig. 2.”C”, then rotate it by 30° clockwise (Fig. 2.”D”).
4) Use the special anti-break-in setscrew wrench supplied and loosen
the dowel until it is secured to the bottom of the push-button board
(Fig. 2.”E”).
1) GENERAL OUTLINE
Programmable digital pushbutton panel for controlling pedestrian and
vehicle access points using two operating methods:
1 - Serial connection:
Manages control panels provided with serial connection.
Up to 16 different codes can be memorised. Each valid code sends
a start command through the serial line.
2 - Interfaced with a Compass system:
The pushbutton panel is integrated in the Compass access control
system.
Provided with an anti-break-in metal container, the Seletto pushbutton panel does not directly control access point opening. Therefore,
it can also be safely installed in unprotected areas.
2) TECHNICAL SPECIFICATIONS
Power supply: ........................................... 12/24 Va.c./d.c. ±10% 50Hz
Absorption: ................................................................................. 60 mA
Working temperature: ........................................................ -10 / +55°C
No. codes (serial connection): ...........................................................16
Dimensions: ............................................................................ see fig. 1
Degree of protection: .................................................................... IP 44
3) INSTALLATION
Various types of mounting are possible:
3.1) Recessed mounting on wall (SELETTO)
Make a hole where the supplied plastic container is to be inserted, this
will be held in place by concrete filling (Fig. 1a).
3 fixing clips are supplied (Fig. 1a “G”) to be screwed on the container
before carrying out concrete filling.
After the concrete has set, the 3 screws must be removed to allow the
gasket and metal ring nut to be subsequently fitted.
4) CONNECTION DIAGRAM
WARNING! In case the power is supplied by an external generator, it
should feature a very low safety voltage and the generator be protected
against short-circuit and overloading.
JP1
1-2
3-4
5-6
Power supply input 12/24 Va.c./d.c. ±10% 50Hz
1 - + 12/24 Va.c./d.c.
2-0V
Serial output towards control panels:
3-TX1
Data output for connection to Compass: 5-DØ
4-TX2
6-D1
5) DIP-SWITCHES
DIP 1
ON
- Connected to COMPASS system
The code is transmitted through outputs 5/6 to a COMPASS system for
subsequent check and activation.
OFF
- Serial operation
The entry of a valid code, programmed in the pushbutton panel internal memory, causes a Start signal to be sent through serial output
TX1-TX2.
DIP 2 (only for serial operation)
ON
- Normal operation, wait for code entry.
OFF
- Activates the code programming mode.
JP2
Power supply selection at 12Va.c./d.c. or 24 Va.c./d.c.
JP2 open
Power supply 24Va.c./d.c. (Fig. 3)
JP2 closed
Power supply 12Va.c./d.c. (Fig. 4).
6) SELETTO PUSHBUTTON PANEL IN A COMPASS SYSTEM
(DIP1 ON)
Proceed to connect the SELETTO pushbutton panel, with reference to
Fig. 4 and the specific instructions for the Compass system.
In this type of installation, the pushbutton panel transmits the code
typed by the user to the Compass control logic, which will recognise
and control the access point.
Therefore, no programming is required for the pushbutton panel.
The codes are exclusively managed by the COMPASS system, if necessary supported by the SECURBASE access management software.
The limit of the codes recognised depends on the characteristics of the
Compass system where the pushbutton panel is incorporated.
Notes:
•
Enter the code quickly during memorisation(within the time allowed
by the Compass 485).
•
The code typed, equivalent to a Compass system card code, must
necessarily include 6 figures.
•
The configuration of the 485/232 Compass system requires 3 Codes
composed of 6 figures (Code+, Code-, Jolly Code) equivalent to
the MasterCards (+, -, Jolly). During the MasterCards generation
procedure, type 6-figure codes instead of inserting the card.
SELETTO - Ver. 04 - 5
•
•
INSTALLATION MANUAL
The 12Va.c./d.c. power supply can be obtained from outputs 13-16
of the 485/232 Compass system, which can supply up to 2 Seletto
pushbutton panels.
For further information, refer to the specific instructions for Compass
use.
EXAMPLE FOR ENTERING A CODE INTO A COMPASS 485 SYSTEM:
Enter the required code, i.e. 741258.
1) turn ON dip switch n.6 of the COMPASS 485 board.
2) type a 6-figure number of your choice, i.e. 123456 (this becomes the master card +).
3) turn OFF dip switch n.6.
4) type code 123456 (card +) then immediately afterwards the
required code 741258 (within the time allowed by Compass
485 (5s)).
5) now just type code 741258 to energise the opening contact
for the COMPASS 485 board. (terminals DOOR 3-4 JP1).
Proceed as described in point 2 for entering any further code.
For the other functions described in the instructions for COMPASS 485, also produce the MASTER CARD and MASTER
CARD JOLLY, repeating from steps 1-2-3 in the example, and
turning ON dip switches 7 and 8 respectively.
7)SELETTO PUSHBUTTON PANEL IN A SERIAL SYSTEM (DIP1 OFF)
7.1) Preliminary checks
•
The access point to be controlled by means of the pushbutton panel
must necessarily be provided with a control panel having serial inputs
and outputs.
•
Moreover, the control panel must be set to SLAVE, and have a
Zone address other than 0.
•
In the case where it is necessary to control more than one access
point by means of the pushbutton panel, connect the other control
units, still set to SLAVE and still having a Zone address other than
0, by means of the serial line. Control units with an identical zone
address answer to the same code,
•
The 24Va.c./d.c. power supply can be drawn from outputs “24Va.
c./d.c. – Power supply for accessories” on the control panel.
Check maximum absorption of the devices connected.
•
The entry of a valid code causes a START command to be sent
along the serial line. Further entries of the same code will cause
further START commands to be sent.
The operator will behave differently depending on the function logic
set on the control panel (2/3/4 steps),
•
For further information, refer to the specific instructions for control
panel use.
Following the diagram in Fig. 3, proceed to wire the serial line of the
control panels managed by the SELETTO pushbutton panel, exclusively
using a telephone-type line.
In the case where a telephone cable has several pairs of wires, it is
indispensable to use the wires from the same pair.
The length of the telephone cable between one appliance and the
next must not exceed 250 m.
7.2) Programming of activation codes (DIP2 OFF)
The Enter function is obtained by simultaneously pressing key 0 and
key 8. Programming can only be carried out when the pushbutton panel
is supplied with power.
1 Press Enter (0+8) N times, where N represents the number of figures
wanted to make up the activation code (from 3 to 6 figures).
2 Type the memory location used by the code (from 0 to 15) and
press Enter (0+8). A maximum of 16 different codes are therefore
possible.
3 Type the number of the serial zone be controlled with the code (from
1 to 127) and press Enter (0+8). Do not enter value 0.
4 Enter the activation code, having 3 to 6 figures (see point 1), and
press Enter (0+8).
5 If Enter (0+8) is pressed again within 10s, the procedure is resumed
from point 2 (entering position⇒zone⇒code).
For example. to attribute code 88776 to position 12, in order to activate
serial zone address 2, proceed as follows:
1 Press Enter (0+8) 5 times
2 Type 12 (location number) and press Enter (0+8)
3 Type 2 (zone number) and press Enter (0+8)
4 Type 88776 (access code) and press Enter (0+8)
5 To end programming, press any key or wait for 10s.
At the end of programming, reposition DIP2 to ON.
6 - SELETTO- Ver. 04
7.3) Making changes to a pushbutton panel already programmed
(DIP2 OFF)
Note: To be able to add codes and/or change pushbutton panel
programming, it is indispensable to know at least one valid code
number.
7.3.1) Addition of new codes
1 Press Enter (0+8) 3 times.
2 Type a valid code number entered in the memory and press Enter
(0+8).
3 Type the memory location taken up by the code to be added (from
0 to 15) and press Enter (0+8). Using a location already taken up
causes the previous code to be cancelled.
4 Type the number of the serial zone to be controlled with the code
(from 1 to 127) and press Enter (0+8). Do not enter value 0.
5 Enter the activation code, having 3 to 6 figures, depending on the
number of figures set in the first programming phase (par. 7.2), and
press Enter (0+8).
6 If Enter is pressed again, the procedure is resumed from point 3
(entering position⇒zone⇒code).
7 To end programming, press any key or wait for 10s.
7.3.2) Cancellation of codes
This operation is used to cancel all the previously programmed codes
and settings from the memory.
1 Press Enter (0+8) 4 times.
2 Type a valid code number.
3 Press Enter (0+8) and keep it pressed for at least 10s.
4 It is now possible to proceed to a new programming procedure (see
par. 7.2).
At the end of programming, reposition DIP2 to ON.
8)
1)
2)
3)
4)
WARNING
Waiting over 10s between typing one figure and the next causes
the entry to be cancelled, and therefore it must be repeated.
The acoustic signal can emit 3 types of sounds:
brief single sound
= number entered
long sound
= Enter (0+8) typed
brief continuous sound = error (function not valid)
After consecutive entry of 5 invalid codes, the acoustic signal emits
the error sound for 60s, during which time no other attempts at access
can be made. Any further incorrect code causes other error signals
to be emitted, with consequent waiting time.
Record the code numbers entered, especially in the case of installations having numerous access codes. The table in Fig. 5 can be
filled in and given to the user. Keep these instructions and the access
codes in a safe place which is only known to authorised persons.
9) MAINTENANCE
Installation maintenance must exclusively be carried out by qualified personnel.
10) DISPOSAL
ATTENTION: disposal should only be carried out by qualified
personnel.
Materials must be disposed of in conformity with the current regulations.
In case of disposal, the system components do not entail any particular
risks or danger. In case of recovered materials, these should be sorted
out by type (electrical components, copper, aluminium, plastic etc.).
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and
commercial improvement of the product, while leaving its essential
features unchanged, at any time and without undertaking to update
the present publication.
D811409_04
D811409_04
•
•
MANUEL D’INSTALLATION
1
2
3
4
5
3)
4)
D811409_04
D811409_04
•
•
•
•
MONTAGEANLEITUNG
4
D811409_04
D811409_04
•
•
•
MANUAL DE INSTALACIÓN
1
2
3
4
5
D811409_04
D811409_04
PORTUGUÊS
•
•
•
MANUAL PARA A INSTALAÇÃO
3)
4)
D811409_04
PORTUGUÊS
D811409_04
D811409_04
Fig. 3
D811409_04
Fig. 5
SELETTO
ZONE
CODE
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SELETTO + COMPASS
CODE
MASTER CARD +
MASTER CARD MASTER CARD JOLLY">