Manuale utente - User Guide Sistema domotico By-me By


Add to My manuals
71 Pages

advertisement

Manuale utente - User Guide Sistema domotico By-me By | Manualzz
Manuale utente - User Guide
Sistema domotico By-me
By-me home automation system
ITALIANO ...................................................................................................................................................... 1
ENGLISH ..................................................................................................................................................... 33
Nome Utente
Nome Utente
2
1
2
Indice
1. CONOSCERE LA CENTRALE................................................................................................... 4
2. IMPOSTAZIONI ......................................................................................................................... 7
3. CLIMA ....................................................................................................................................... 9
4. AUDIO ..................................................................................................................................... 14
5. GESTIONE LAMPADE RGB ................................................................................................... 20
6. SCENARI ................................................................................................................................. 22
7. EVENTI .................................................................................................................................... 25
8. IMPIANTO ANTINTRUSIONE ................................................................................................. 27
9. GESTIONE ENERGIA ............................................................................................................. 29
10. PULIZIA DELLA CENTRALE................................................................................................. 31
3
SIMBOLO ASSOCIATO

oppure
o di
.
4
<
o destra
>
5
Fig. 2
Setup
Fig. 3
per
7
Esci.
Imposta; la
8
Menu
Setup
Fig. 4
);
Salva.
9
10
Menu
Menu
Setup
Fig. 5
Menu
Setup
Indietro
oppure un
Salva.
:
Radio FM
98.25 MHz
Deejay
Scan
Fig. 8
98.25 MHz
Deejay
Scan
Deejay
98.25 M
Deejay
Scan
e
15
Dockingstation 1
Queen
Best of Queen...
We will rock
Fig. 11
16
Audio
Dockingstation
1
Dockingstation
1
Queen
Queen
BestI of
Queen...
Best
of
Queen...
tasti attraverso i quali si
We will rock We will rock
•
e
Dockingstation 1
Fig. 12
controllato
localmente localmente
,
e
17
Dal menù Playback, toccando
Fig. 13
Fig. 14
• Dockingstation
Effettuare dei 1
a sx
< e a dx >
Queen
Dockingstation
1 per selezionare una categoria o un suo elemento specifico.
of Queen...
• Best
e
We
Queenwill rock Dockingstation 1
Dockingstation
1 Menù di Playback.
Best• of Queen...
per ritornare alQueen
We will rock BestQueen
of Queen...
Best of Queen...
•
per riprodurre
We will rockla categoria selezionata.
We will rock
oppure
•
•
•
18
•
•
per tornare alla Playlist.
•
Interfaccia IR
COMANDO
Play
COMANDI
Sel. Sorgente 1
Sel. Sorgente 2
Sel. Sorgente 3
COMANDI
Pausa
Riprendi
COMANDO
Skip +
Fig. 15
19


Gruppi
Dimmer dx
1
2
1
Aggiungi
Indietro
Esci
Fig. 16
Dimmer dx
Scorrere
Indietro
Salva
Fig. 17
20
>
00:12
00:33
Salva
Salva.
21
, una ad una, le
Mem ed infine confermare con Salva.
23
 Pulsanti
Chiudi.
24
Setup
Fig. 19
Toccando
Setup
Menu
25
Salva.
la voce
26
Durata ON [h:min]
Salva per confermare.
27
•
28
12:00
KW
10.2
10.2 KW
Setup
Indietro
Fig. 22
29
 Reset
Indietro
Indietro
Indietro
Indietro
Indietro
Indietro
Indietro
Indietro
Indietro
Fig. 23
30
Reset
Reset
Reset
31
User Name
User Name
32
Space reserved for noting down the password (from 5 to 8 digits)
Space reserved for noting down the anti-theft system
keypad codes (5 digits)
CONGRATULATIONS on choosing the Vimar By-me system!
The By-me home automation system is a byword for technological evolution that enables you to make
your home comfortable and functional, simply and safely.
Vimar, always attentive to people's needs and constantly searching for innovative solutions that make
everyday life comfortable and secure, is proud to offer you a home automation system that is recognized as one of the most advanced and reliable systems currently on the market.
Before beginning to use the system please take a few minutes of your time to read this manual that
will allow you to get familiar with the functions of the control panel and system.
Always ask your local installer to give you all the documents and information that can come in useful
for the support service and, for this purpose, keep the receipt of purchase and all the documentation
supplied.
For any information on system operation or its parameters always refer to your local installer.
Thank you for choosing to let Vimar into your home with our By-me system.
33
34
Table of Contents
1. GETTING TO KNOW THE CONTROL PANEL................................................ 36
2. SETTINGS ..................................................................................... 39
3. HVAC ........................................................................................... 41
4. AUDIO ......................................................................................... 46
5. MANAGING RGB LAMPS ..................................................................... 52
6. SCENARIOS ................................................................................... 54
7. EVENTS ........................................................................................ 57
8. INTRUSION DETECTION ALARM SYSTEM .................................................. 60
9. POWER MANAGEMENT....................................................................... 62
10. CLEANING THE CONTROL PANEL.......................................................... 64
35
Getting to know the control panel
1. GETTING TO KNOW THE CONTROL PANEL.
The control panel is the nerve centre of the system.
With no buttons thanks to the innovative touch screen display, it enables accessing the system functions and the
menus that govern them by simply touching the icons or the words displayed.
1.1 Navigating through the control panel menus.
As said before, to navigate through the control panel menus simply touch the words or the icons displayed
till you reach the desired screen.
The control panel moreover also displays step by step indications of the operations to perform to reach the desired
menu or function.
Depending on the type of option to select, the touch can be made in four different ways:
MODE
ASSOCIATED SYMBOL

Brief and single touch
or
Prolonged pressure
Quick tap, movement in which the point of release is not significant; it is
equivalent to the action of pushing a virtual object with a finger to move it
quickly in a specific direction.
Dragging, movement in which the finger is released only after establishing
the final position for a certain fraction of time; it is equivalent to the action
of dragging a virtual object with a finger.
If you want to make a single movement it is advised to release the finger
only after seeing the movement.
If instead you want to make repeated movements you need to maintain the
pressure on the display.
The symbols shown in the table above are the ones used in this manual to indicate the method of selecting the
various menus of the control panel.
In general:
• To select an option in a list, it is necessary to highlight the desired item performing vertical
actions and then do a
or
in the central zone (it is not necessary for it to be above the element under focus, the
important thing is that it is not over a button or an icon).
• It is possible to quickly scroll through the elements of a list by performing an action of
.
The initial scrolling speed is slow enough so as to allow reading the words; if you want to increase the speed it is
necessary to do a subsequent
while scrolling.
36
Getting to know the control panel
• During navigation, arrows pointing left
or
actions.
< or right >
identify the possibility of performing horizontal
• The sensitive area for
and
actions is equivalent to all the display of the control panel and acts
on the element that has the active focus on the page.
• Being a touch screen display, it is advised to use a fingertip with a light pressure that however is more than just
skimming over it; performance increases if you press with a fingertip or even better with a nail.
• It is permissible to use a specific stylus for a touchscreen; whereas it is recommended not to use any sharp
object such as a pen, screwdriver, electric cable, etc., to avoid damaging the display.
Each action carried out on the display is associated with a different acoustic signal that is only played if the action
is permissible.
1.2 Control panel main screen.
The control panel's main screen displays the list relating to the main menus:
• HVAC;
• Temperature Probe;
• Scenarios;
• Events;
• Alarm System;
• Audio;
• Power Management.
Main Menu
Climate
Temperature Probe
Scenarios
Events
Audio
Logout
Setup
Fig. 1
The main menu is selected by touching the name of the one you want; the selection is highlighted by the black
band and by the name that becomes white in colour.
The Alarm System, Audio and Power Management menus are displayed in the second part of the screen which is
accessed by simply touching the white cursor on the right and moving it downwards
(Fig. 2-3).
37
Getting to know the control panel
Main Menu
Climate
Temperature Probe
Scenarios
Events
Audio
Logout
Setup
Fig. 2
Main Menu
Events
Alarm System
Audio
Power Management
Logout
Setup
Fig. 3
If, after a time-out of approximately 90 s, no operation is carried out, the control panel display switches off, activating a stand-by screen that displays the time, day and date.
If personal security codes have been set (installer PIN, different users, etc.), access to the menus is only possible
after entering the code permitting use, by the user, only of the menus for which the user has been enabled (see
paragraph 4.5.4).
The control panel moreover enables creating different users (up to 17 users), each one of which is assigned a
specific password that associates the functions of the system that can be managed.
The types of user are the following:
• Administrator: your local installer who has full access to the parameters and to the configuration of the
system (he can therefore carry out any operation).
• Ev. Prog. User: a reserved system user (for the Events).
•G
uest: a generic user without a password that can only use some functions but cannot change them (for
example he cannot operate on the anti-theft system).
IMPORTANT: Always ask the installer to create your profile and assign it with privileges.
38
Settings
2. SETTINGS MENU.
The Settings menu is used to set the control panel's clock, select the current language, set the colour of the
display and the tones of the buttons, the preferred applications to display on the start-up screen, the time-out for
activating the screen saver, displaying the temperature measured by the probe (where applicable) and the unit of
measurement of the temperature.
2.1 Setting the clock.
Used to set the date and time.
Main Menu  Setup  Settings  Date and Time  Select Master or Slave
• Select Master  Automatic EU or Daylight Saving or Solar and by
you go to set up respectively:
to view and select the values,
- Automatic EU; once entered manually current date and time, the control panel will automatically switch from
daylight saving time (last Sunday in March at 2:00) and from daylight savings time (last Sunday in October at 2:00).
- Daylight Saving; to be used in non-European countries, this option allows you to enable daylight saving time
manually inserting it.
- Solar; to be used in non-European countries, this option allows you to enable solar time manually inserting it.
• If you select Slave the date and time cannot be entered with the control panel (the display will show the pop-up)
but will be set automatically by the web server (where applicable).
Confirm with Save; in both cases, the control panel will confirm the operation has been completed.
Important: The control unit can be Slave only to a Web Server Master.
The touch screens can be Master only in a By-me system without control unit and only one Master
touch screen can be set in the entire system.
A deviation from the correct time occurs in case of settings other than the above.
2.2 Setting the language.
Used to set the national language in which the menus are displayed. The available languages are Italian, English,
German, Spanish, French and Greek.
Note: If the user does not have the necessary privileges you will be asked to change user.
Main Menu  Setup  Settings  Language
The active language is signalled by the symbol ; perform
and touch
to scroll through the list of available languages
the one you want. Confirm with Save; the control panel will display the confirmation of the operation.
2.3 Display and Tones.
Used to set the parameters of contrast and backlighting of the display, the tones of the icons for using and programming the control panel and performing the touch screen calibration function.
Main Menu  Setup  Settings  Display and Tones
It is then possible, by touching
- Contrast of the Display  Use
the desired one, to set the following parameters:
to select the desired value  Save
39
Settings
- Backlighting  Use
to select the desired value  Save
- Keyboard tones  Use
to select the desired value  Save
- Touch calibration (a pop-up will be displayed to illustrate the procedure to follow)  Next
NOTICE: It is not possible to stop the touch calibration function. Once started it must be completed.
Exit.
To exit the menu touch
2.4 Favourite Application.
Used to set the start-up screen you want to be displayed.
Main Menu  Setup  Settings  Favourite Application
Scroll with
upwards or downwards through the menu items and select the desired application; confirm
lastly by touching
Save.
The control panel confirms the operation has been completed.
2.5 Screen saver.
Used to set the time of inactivity at the end of which the control panel activates the screen saver and cuts off the
display backlighting.
Main Menu  Setup  Settings  Screensaver
-Touching
Off disables the screen saver.
-Touching
saver.
Delay enables setting the inactivity time at the end of which the control panel activates the screen
With
upwards or downwards select the desired value then touch
the operation carried out.
Set; the control panel confirms
The activation time of the screen saver set by default is equal to 1 and a half minutes.
NB: If the screen saver is disabled, after 1 and a half minutes only the display backlighting is cut off.
2.6 Temperature Probe
Once the installer has correctly configured, connected and enabled the probe, it is possible to view the measured
temperature.
Main Menu  Temperature Probe
The display will show a screen that shows and periodically updates the current temperature measured by the
sensor. The temperature value is given in the unit of measurement configured on the device (see the following
paragraph 2.7).
Touching
40
Menu takes you back to view the main menu of the control panel.
HVAC
2.7 Temperature Unit
Used to select the temperature unit from degrees Celsius or degrees Fahrenheit.
Main Menu  Setup  Settings  Temperature Unit
Scroll upwards or downwards with
and select the desired unit of measurement; lastly
touch Save.
The control panel confirms the operation has been completed.
3. HVAC.
The HVAC menu allows reading off the control panel the temperature measured by the various thermostats and
changing the type of operation or the setting temperature of each single thermostat. In addition, again via the
control panel, it will be possible to make each thermostat work in a completely similar manner to that of a timerthermostat (AUTO mode) by setting the operating temperature and the related time bands. Through the climate
control menu, if the climate controller is installed in the system, also all the options associated with it are displayed.
3.1 Viewing the temperature of the thermostats in the different zones of the house.
Main menu  HVAC  View, moving
system has been divided
to the left (<) or to the right (>), the zones in which the
Climate
Zone 23
Thermostat 23 Library
Menu
Setup
Fig. 4
For each zone the display shows:
• the measured temperature;
• the state of the thermostat (On if it is working to take the HVAC to the set temperature, Off if the temperature
has been reached);
• the operating mode (Heating
or Air-Conditioning
);
• the type of operation (Manual, Automatic, Timed Manual, etc); in the presence of control of the fan coil, the
display also shows the
icon that identifies the fan speed.
Touching
Menu takes you back to view the main menu of the control panel.
3.2 Selecting the temperature zone to be displayed.
Used to set the zone to be displayed on the control panel when accessing the HVAC menu.
HVAC  Setup  Zone settings  Select the desired zone  Monitor zone  Select ing on or off
Confirm with Set and lastly touch
Save.
41
HVAC
The control panel confirms the operation performed and goes back to the settings for the temperature zones.
After defining the temperature zone the HVAC menu will be displayed as illustrated in the example of Fig. 4.
• Touching
• Touching
Menu displays the control panel's main menu;
Clima
Setup Zona
displays
the zone parameters;
23
Termostato 23 Biblioteca
• Touching Clima
Zona 23
Termostato 23 Biblioteca
displays
the thermostat operating mode;
Setup
Menu
• Touching
manually forces the current temperature set point independently of the current operating
Menu
Setup
mode or, for thermostats that allow the control of the fan coil, you can set the fan speed.
3.3 Operating modes.
As mentioned in par. 3.1, it is possible to select the desired thermostat to view the read temperature and check
whether the zone is active; in addition it is possible to change the type of operation. Depending on the installed
thermostat (display with buttons or touch screen) modes of operation are as follows:
Thermostat with buttons (art. 20513, 20514, 19513, 19514, 16953, 16954, 14513, 14514)
• OFF = off.
•T
IMED OFF = off for a selectable number of hours (then it switches back on returning to the previous operation).
•A
NTIFREEZE = the thermostat switches on in HEATING mode only if the ambient drops under the set antifreeze
temperature (e.g. 6°C).
• REDUCTION = manual temperature typically used at night (e.g. 18°C in winter).
•T
IMED REDUCTION = as above, for a selectable number of hours (then it returns to the previous operation).
•M
ANUAL = is the classic operation of traditional thermostats (the desired temperature is set manually with no
time limit).
•T
IMED MANUAL = as above, for a selectable number of hours (then it returns to the previous operation).
• AUTOMATIC = activates a weekly programming that has been configured in the control panel.
• OVERRIDE = this option, which can be used when the timer-thermostat is operating on Automatic with daily or
weekly programming, is used for temporarily changing a previously set temperature value within the program.
This function is useful when, at a certain time, the desired temperature is different to the programmed one; in
particular, it is possible to define a different temperature value to the one set in the program and for a time interval
that can also be set.
Thermostat with touch screen (art. 02951)
• OFF = off.
• PROTECTION = Depending on the heating mode (winter) or cooling (summer), the thermostat activates respectively Antifreeze or Too hot protections to prevent the risk of damage to the system.
• REDUCTION = manual temperature typically used at night (e.g. 18°C in winter).
•M
ANUAL = is the classic operation of traditional thermostats (the desired temperature is set manually with no
time limit).
•T
IMED MANUAL = as above, for a selectable number of hours (then it returns to the previous operation).
42
HVAC
• AWAY = lets you set the set-point in order to achieve significant energy savings during periods when the user
is away.
• AUTOMATIC = activates a weekly programming that has been configured in the control panel.
Note.
If a Timed mode is selected, the control panel stores the previous mode and returns to this mode after the set
time has elapsed.
HVAC  Select, moving
Clima
Zona 23
to set the mode Termostato
23 Biblioteca
Touching
to the left (<) or to the right (>), the zone in which you want
displays
the list with the operating modes; select the desired one by touching
Setup
Menu
the corresponding word.
Climate controller for heating systems (art. 01465)
Climate
Zone 24
Climate regulator
48.0°C
Delivery water
temperature
Menu
N.B. In case of temperature probe
failure the dashes --- will be displayed instead of the temperature
value.
Setup
Fig. 5
• Touching
• Touching
Menu displays the control panel's main menu.
Clima
Setup Zona
displays
the zone parameters (Zone settings, Zone programming, Monitor zone).
23
Termostato 23 Biblioteca
• Touching
displays
the thermostat operating mode:
Setup
Menu
- AUTOMATICO = activates weekly programming that has previously been configured on the control panel.
- COMFORT = is the classic operation of traditional thermostats (the desired temperature is set manually with
no time limit).
- ECONOMY = manual temperature typically used at night.
Clima
24
- OFF Zona
= off.
• Touching
the set point is manually forced; according to the type of operation mode set in the climate
Menu
Setup
controller it may be:
- Fixed Mode: delivery temperature set point.
- Modulating Mode: desired ambient temperature set point.
IMPORTANT: The incorrect setting of this value may prevent the controller delivery valve from opening.
43
HVAC
3.3.1 Setting the speed of the fan coils
The thermostats for controlling the fan coils permit adjusting the speed of the fans via a specific menu that can be
shown on the display of the device or on the control panel.
There are two methods of adjustment: manual and automatic.
• on selecting manual mode the user sets the desired speed;
• on selecting automatic mode the speed is adjusted
Clima by the thermostat according to the difference between the
Zona 23
ambient temperature and the set point; theTermostato
greater
difference the greater the speed.
23the
Biblioteca
HVAC  Select the desired zone and touch
Menu
Setup
 Fan coil speed  Select the desired speed:
- Minimum
- Medium
- Maximum
- Automatic
Touch
lastly Save to confirm; after a time out the selected speed will be set.
3.3.2 Temperature zone setting
The following menu is used to set some parameters of the selected temperature zone.
Climate control  Setup  Zone settings  Select the zone tapping the
associated name
The following parameters can be set:
• Type of control (heating/air-conditioning): Sets the operation in heating or air conditioning system.
If the zone is provided with thermostat or the temperature probe, also the following parameters (not shown in the
case of the climate controller) can be set:
• Aux. heat threshold: It is used to set the difference between the measured temperature and the setpoint temperature after which the auxiliary heating (if configured) starts operating.
• Aux. cond. threshold: It is used to set the difference between the measured temperature and the setpoint
temperature after which the auxiliary air-conditioning (if configured) starts operating.
• Ecometer: Enables the ecometer function. If this function is disabled, the backlighting is fixed and turns to the
colour set in the Backlight Colour parameter; otherwise the backlighting varies according to the set setpoint.
• Backlight colour: Sets the backlight colour of the thermostat.
• Temperature unit: Sets the unit of measurement [°C or °F] used to show the temperature on the display.
3.4 Creating or modifying the automatic program of a thermostat.
To access this menu it is necessary to enter the password of an enabled user (enabled by the installer when he
creates the various users).
Programming the HVAC zones is subdivided into two phases; selecting the desired temperature levels and the
subsequent time programming.
T1/T2/T3 are the 3 temperature levels you want to use during the day; for example, T1 can indicate the minimum
temperature in the night, T2 the average temperature when no one is at home and T3 the “comfort” temperature.
The time programming moreover enables setting a temperature value T every 20 minutes for each day of the week
obtaining the utmost in terms of comfort and savings.
44
HVAC
3.4.1 Setting the automatic program
The By-me system can be used to create personalized programs for automatic heating or air-conditioning control.
The personalization consists of setting the value of a temperature level - that can be selected from between three
different ones (T1, T2 and T3) - every 20 minutes; in the heating and air-conditioning programs the values T1, T2
and T3 are differentiable.
Select the zone to be programmed.
HVAC  Setup  Programming zones  Select the HVAC zone  Programs
Select the program to be created:
Heating prog.
Air-conditioning prog.
Select the day associated with the program to make then touch
Edit program (Fig. 6).
Edit Programme
Mon
Back
Set
Fig. 6
- With
or
, set the time slot when to change the temperature level.
- With
upwards or downwards, select the desired level of temperature from the three available ones
(icons T1, T2 and T3); the histogram will be updated.
Touch
C if you want to expand the set level T1,T2 or T3 forwards or backwards; if C is not selected/activated
each movement will not alter the current setting.
- Repeat the procedure for all time slots to be changed, then confirm with Set.
Move onto another day of the week and proceed as above; using Copy from....., it is possible to assign the selected day with the program of any other day of the week; then select the day to copy and touch
the configuration with Save.
Set. Save
3.4.2 Setting temperature levels.
HVAC  Setup  Programming zones  Select the HVAC zone  Temperature levels
Select:
Heat. T1 [°C], Heat. T2 [°C], Heat. T3 [°C] or Air-con. T1 [°C], Air-con. T2 [°C], Air-con. T3 [°C]
Insert the desired value and confirm with Set; at the end of the operation touch
Save.
The control panel confirms the operation carried out and returns to displaying the page with the settings of the
programs relating to the previously selected temperature zone.
45
Audio
4. AUDIO.
The Audio menu, only active if the By-me speaker system is also installed, allows managing the functions of the
Hi-Fi system; from the control panel it will then be possible to select the audio source (radio, iPod, etc.) and the
song to listen to, save the favourite radio station, activate/deactivate the audio zones and actuate the wake-up
function.
Audio
Zone 23
Audio Library 2° Floor
FM Radio
102.5 MHz
Menu Setup
Fig. 7
4.1 Functions on the audio zone.
After creating the groups and then the audio zones, the main menu shows the zones created, that can be scrolled
through by moving
to the left (<) or to the right (>).
For each zone the display shows the number and the description, the description of the group of the transmitter
module and, where applica-
Audio
module
Zona
23 associated with the channel (audio source), the description of the transmitter
Audio Biblioteca
2° Piano
ble, some
supplementary information (in this case the frequency for the FM tuner).
Radio FM
102.5 MHz
the
icon a submenu is displayed in which touching
:
MenuWith
Setup
- Switch off zone (dynamics depending on the status) switches off the zone;
- Change sound source selects the sound source to play.
When the same icon corresponds to the speaker symbol with ON written above, it means that the zone is off;
On touching it
will switch on.
4.2 Radio management.
The radio can only be managed if the system is equipped with an FM tuner.
FM Radio
98.25 MHz
Deejay
Scan
Fig. 8
46
Save
Audio
Figure 8 illustrates the screen for controlling the FM tuner transmitter module.
In the middle zone there is the frequency being used, the related signal strength (RSSI) and, only if enabled, the
RDS text is displayed.
The word Scan indicates how it activates one of the three selectable setting modes, namely Mem, Scan and
Freq.
Radio FMRadio FM
The icons
In Mem
and
98.25 MHz
98.25 MHzperform the action of increasing and decreasing according to the selected
Deejay Deejay
Scan
Scan
mode the frequency
being used corresponds to the value of one of the station memories.
98.25 MHz
Deejay
Scan
 Saving the radio stations
In the Scan or Freq modes it is possible, by touching
the icon
in one of the 8 available station memories.
Set the desired station number, select Next and confirm with Yes.
mode.
, to save the current frequency
Save Station
2
3
4
5
Next
Back
Fig. 9
 Selecting stations in memory
Touching
Mem activates the mode for calling up previously saved stations; with icons
and
you can call up one of the 8 saved FM stations.
The number alongside Mem is the selected station number.
 Automatic search for radio stations
Touching
Scan activates the automatic radio station search mode; with icons
move in one of the two directions.
Radio FM
Radio FM
98.25 MHz
and
98.25 MHz
Deejay Deejay
Scan Scan
you
The parameters affecting the search can be changed via the menu for the device parameters.
 Frequency selection
Touching
Freq activates the mode for setting the current frequency; with icons
and
you
move in one of the two directions. Keep the icons pressed for scrolling faster.
47
Audio
4.3 Managing the Docking Station
The Docking Station is controlled with two menus:
- the track playback menu (Playback) that is accessed from the Zone Menu;
- the database navigation menu in the Docking Station that is accessed from the Playback Menu.
If no iPod/iPhone is connected to the Docking Station or a jack connector is connected to the socket of the auxiliary source, the Zone Menu will show the notice Dockingstation? and it will not be possible to use the Playback
Menu or play back songs (the button at bottom left is inhibited).
Audio
Zone 23
Audio Library 2° Floor
Docking station
?
Menu Setup
Fig. 10
If an iPod/iPhone is connected, the Docking Station sends a message to the control panel and it is then possible
to open the Playback Menu by touching the Details icon (the button at bottom left that is now enabled).
4.3.1 Playback Menu
The Playback menu of the Docking Station is composed of a main screen on which the middle part is used for a
full display of the relevant information on the tracks being played.
Docking station 1
Queen
Best of Queen...
We will rock
Fig. 11
48
Audio
Dockingstation
1
Dockingstation
1
Queen Queen
Best
of
Queen...
Best
of
Queen...
The buttons used to manage
We will rockWe will rock
•
and
the iPod/iPhone are the following:
to play the previous or next song.
Dockingstation 1
ockingstation
1to access
Queen
•Dockingstation
Best of Queen...
1 the Navigation Menu of the Docking Station.
Dockingstation
1
Queen
We
will rock
Queen
Dockingstation
1
Queen...
BestBestofQueen
pause song playback and restart it at the point where it was stopped.
of Queen...
Queen...• Best ofto
We will rock
Queen
will rock
WeWewill
rock
Dockingstation
1
1
Best of•Queen...toDockingstation
return to the Zone Menu.
Queen
Queen
We will rock
Best
oforQueen...
Best ofofQueen...
•
to set repetition
a single
track
of a group of tracks.
We
will
rock
We
will
rock
•
to set random repetition of a group of tracks.
kingstation 1
Dockingstation 1
Queen Touching
the twoQueen
icons
and
opens a new page for selecting playback mode; the 4 options
Best of Queen...
Best
of
Queen...
shown below are displayed and by touching
each one you can enable/disable the related playback mode.
We will rock
We will rock
The icons corresponding to the selection made will then be on the Playback menu selection button.
no repetition
random group of tracks
single track
ordered playback
group of tracks
random group of albums
If the Docking Station is controlled Locally (that is to say directly from the iPod/iPhone) the Playback Menu will
not display the song being played and the tracks will be managed with the three command and playback icons.
Docking station 1
I-Pod
locally
controlled
Fig. 12
4.3.1.1 Operation
The main screen of the Playback Menu shows the relevant information on the Artist, Album, and Song being
played.
Dockingstation
Dockingstation
1
1
This information will always be displayedI-Pod
whenI-Pod
the iPod/iPhone is on Play or Pause while if it is on Stop the
controllato
controllato
displayed fields will be empty. Dockingstation
Dockingstation
1localmente
1
localmente
I-Pod
I-Pod
In the case of Stop and Pause icons
and
will not be displayed.
controllatocontrollato
Dockingstation 1
I-Pod
Pressing each ofcontrollato
the icons
localmentelocalmente
,
and
of the main screen changes song playback as preferred.
localmente
49
Audio
The information on the song being played is continually updated: when the iPod/iPhone starts playing a track the
control panel immediately displays the relevant information.
Dockingstation 1
Song playback
canI-Pod
also be changed by the events generated by By-me rocker switches configured in audio
Groups or by thecontrollato
rocker switches of the receivers.
Touching
Dockingstation 1
I-Pod
Touching
controllato
localmente
Touching
Dockingstation
localmente 1
I-Pod
within
3 s of the
controllato
localmente
start of the song will play the previous song.
after 3 s of the start of the song will play the current song from the start
plays the next track.
4.4 Docking Station Database Navigation
Menu
Dockingstation 1
From the Playback menu, touching
Queen
accesses
the Navigation menu.
Best of Queen...
We will rock
The Docking Station database navigation menu is composed of a main screen on which the middle part is used
for a full display of the navigation information.
The icons and procedures with which the Database is navigated are the following:
Music Archive
Select
Brano:
by Artist
Music Archive
Select by Playlist
Fig. 13
Fig. 14
•Dockingstation
Move
1 to the left
< and to the right >
to display the categories or elements.
Queen
Dockingstation
1
of Queen...
• Best
and
to select a category or one of its specific elements.
We
will rock
Queen
Dockingstation 1
Dockingstation
Best• of Queen...
to returnQueen
to the1 Playback Menu.
Queen
We will rockBestBest
of Queen...
of Queen...
•
to play
selected
category.
We the
will rock
We will rock
Touching
or
when a specific category has been selected takes you back to the Playback menu.
The docking station navigation menu is composed of different screens depending on the categories and the
selected elements; as a result the icons that can be displayed are the following:
•
to return to the selection menu of the Artists/Playlists category.
•
to select an artist and display his or her albums.
•
to return to the selection menu of the Artists category.
•
to select the album and display the songs it contains.
50
to return to the list of artists.
•
to return to the list of albums.
•
to return to the Playlist.
•
to return to the previous menu.
Dockingstation 1
The database of the iPod/iPhone can be browsed by Playlist or Artist and navigation is permissible also while
Queen
playing a song.
Best of Queen...
Dockingstation
1 type of category currently selected is highlighted by the relevant identifying image.
During
navigation, the
We will rock
Queen
After selecting
the
desired
type of category, it is possible to send it to playback with the
icon thus returning
Best of Queen...
We willto
rock
automatically
the Playback screen.
With
you go back to the Playback menu.
4.5 Details menu of the sound source connected to the RCA port and controlled by the respective infrared remote control.
From the zone menu, it is possible to access the menu of commands associated with the IR interface.
Each command can be associated with a sequence of 1, 2, 3 or 4 actions and this corresponds to consecutively
pressing up to 4 buttons on the remote control of the controlled device.
More precisely, the association of the commands with the 4 menu buttons is the following:
IR Interface
COMMAND
Play
COMMANDS
Sel. Source 1
Sel. Source 2
Sel. Source 3
COMMANDS
Pause
Resume
COMMAND
Skip +
Fig. 15
Important:
All the commands
are cyclic; for example:
Dockingstation
1
I-Pod
controllato
• Touching
1 time activates the Pause
localmente
control; touching it again activates Resume; touching the icon yet
again activates Pause and so on.
Interfaccia IR
• Touching the
button 1 time activates Sel. Source 1; touching the icon again activates Sel. Source 2;
touching the icon yet again activates Sel. Source 3; touching the icon again activates Sel. Source 1 and so on.
51
Notice
NO
Speed
Norm
Duration of absolute 00:02
Switch on value
>
Fadingshow
>
Switch on duration
00:04
Switch off duration
00:02
Back
Save
Preavviso
Back
Save
Durata
reg.
assoluta
Velocità RGB lamps
Norm...
Managing
Fadingshow
Valore
accensione
25%
Durata accensione
>
5. MANAGING
RGB LAMPS.
Devicespegnimento
parameters
Durata
00:02
Opzioni
Notice
NO only be used if the By-me
This lights
management mode, which can
home automation system is equipped
Dispositivi
associati
Duration
of
absolute
00:02
with dimmers and dedicated lamps, by switching on/off and controlling
brightness,
provides efficient
Fadingshow
>
lighting
in the rooms while ensuring optimization
of energy savings.Informazione gruppo
nome
The new RGB functions (patented by Vimar) enable creating colourModifica
changes and
elegant, sophisticated light
Rimuovi
effects.
You can also call up scenarios
involving different functions in
the homegruppo
automation system.
Back
Save
Back
Esc
5.1 Setting the function of Fading Show.
The function of Fading Show allows to choose the color of the light and to set the cyclic transitions between the
different colors by adjusting the speed with which the illumination changes
from one devices
color to the next.
Associated
1
2
0xAFC1 Taste 01
gruppo
SetupInformazione
Configuration
Groups  Automation groups 
Select the
group by scrolling1
0x0123
IR Sensor


Modifica nome
through
the listgruppo
Rimuovi
 Associated devices  Select the functional unit (for example right Dimmer) by
Back
Add
Back
scrolling
through the list Esc
Device parameters
right Dimmer
SelectDispositivi
the device with
which you activate the Fading Show that you0x001C
want to set:
associati
Associated devices
0x001C right Dimmer
0xAFC1 Taste 01
0x0123 IR Sensor
Back
right Dimmer
1
2
1
Device parameters
Remove device
Add
Back
Esc
Fig. 16
right Dimmer
Select Fading Show by scrolling
Velocità
Device
parameters Norm...
Valore accensione
25%
Remove
device
Durata accensione
>
Devicespegnimento
parameters00:02
Durata
Back
Esc
Notice
NO
Duration of absolute 00:02
Fading Show
>
Back
through the paramters list
Device parameters
Fading Show colors
Transition [min:s]
Persistance [min:s]
Back
Save
Fig. 17
52
>
00:12
00:33
Save
Managing RGB lamps
Set the parameters of Fading Show in order to obtain the play of light you want:
• Fading Show colors: select the colors to be reproduced (Red, Orange, Yellow, Green, etc.) up to a maximum
of 6;
• Tansition [min:s]: set the time that elapses between the passage of one color to the next;
• Persistance [min:s]: set the time in which each color is played.
Duration
persistence
Duration of transition
Duration of transition
Fig. 18
Finally confirm the settings by touching
Save.
53
Scenarios
6. SCENARIOS.
This menu is used to create, change and activate the scenarios of the home automation system.
The scenario can be compared to a "photograph" of the house (or part of it) in a specific situation and can include
lights (on/off), dimmer (level of brightness), roller shutters (up/down), thermostats (temperature settings and mode)
and audio (source and volume).
After being configured, the scenarios are saved in the control panel and in the devices involved; they can be called
up from the control panel, with the buttons, the remote controls and also with simple SMS text messages (in this
case there must be the GSM communicator).
The scenarios can only be activated and take the system into the previously saved situation; naturally, after activating a scenario, you can operate on the devices to vary their status manually.
The control panel is able to save up to 32 scenarios of which 4, at your choice, can be activated from the
main screen of the scenarios menu; in this connection ask your installer to associate the four scenarios
you will use most often with the first screen of the menu.
NB: If no association is made, the control panel automatically assigns the main screen with the first 4 scenarios
of the list of the 32 available ones.
Bear in mind that each function (called a "group" on the control panel) can be associated with at most 4
different scenarios; if this limit is exceeded the control panel will display an error message. It is therefore
useful to note down the functions associated with scenarios so as not to run into this eventuality. Lastly,
bear in mind that in the scenarios it is not possible to set roller shutters that remain half open.
6.1 Activating a scenario.
Scenarios  Select and touch
the scenario to activate  Proceed?  Yes
6.2 Creating a new scenario.
A scenario is normally created by the installer or by a user he has enabled.
The procedure is as follows:
1. Select the functional groups involved (this is done at the control panel);
2. Set the users of the groups concerned in the desired state (load ON, load OFF, load dimmed, roller shutter up,
roller shutter down, etc.). This operation must be carried out directly on the actuators and related controls;
3. Store the scenario in memory (this is done at the control panel);
4. Rename the scenario (this is done at the control panel).
Notice: The order in which the first operations 1 and 2 are performed is not important; it is necessary to remember
that the scenario will call up the state of all the actuators in the groups involved.
Scenarios  Setup  Add Normal scenario or Global scenario
Important:
•Select normal when the scenario is composed of functional groups belonging to a single control panel.
•Select global only when the scenario must be composed of functional groups belonging to a number of lines. In
this case, the “Create Scenario” operation must be performed on all the systems and the same Global scenario
must be selected on each of them.
54
Scenarios
Assign the name to the scenario setting:
• Index of new Scenario (1-32) that identifies the number of the scenario in the list of all the configured ones;
touch Next to confirm.
• Scenario name scrolling through
the list of characters displayed and moving
one, the desired letters to form the name; touch
Scroll
, one by
Next to confirm.
through the list of configured groups and select, touching them
one by one, the ones in-
volved in the scenario; the selection will be highlighted by the icon .
Touch Options
 Next to confirm.
In the scenario it is possible to add or remove all the configured groups by touching Select All and Deselect All
respectively.
The control panel asks you to set the state that the actuators will take on when the scenario is activated; using the
buttons of the groups involved set the users positioning them in the desired state (ON or OFF, roller shutter
raised or lowered, thermostat ON, etc.).
For the temperature/thermostated zones select the desired operating mode (for example Automatic, Manual
22.5°C) on the thermostats involved in the scenario.
Finally, for the audio zones select the desired source (RCA input, dock station for the iPod, etc.) and in the case
of FM radio select the desired FM station too and then the listening volume.
Touch
Mem and lastly confirm with Save.
For example, if a light already is lit and in the scenario you want to keep it lit, press the button to switch it on (as if
it were off at the moment); vice versa if a light is lit and you want to associate it off in the scenario, press the button
to switch it off.
In the case of the dimmer, select the desired level of brightness with the buttons.
For the roller shutters/shutters/curtains, use the up/down buttons to select the final position they need to have in
the scenario.
During this phase the green LED of the devices in the groups involved blink to make identification easier. Touch
Next; the control panel will confirm the operation carried out and will return to display the list of configured scenarios.
6.3 Renaming a scenario.
It is possible to change the name of an existing scenario by assigning it a new one.
Scenarios  Select the scenario  Setup  Touch
the selected scenario Edit Name
Scrolling vertically
through the list of characters displayed and move horizontally
the desired letters to form the name; touch
Save to confirm.
, one by one,
55
Scenarios
6.4 Cancelling a button associated with the scenario
The procedure is as follows:
Scenarios  Select the scenario  Setup  Touch
the selected scenario  Associated Buttons  Select the button to delete  Remove Association  Yes
The control panel confirms the operation carried out; touch
Close.
6.5 Modifying groups associated with a scenario.
To modify the groups involved in a scenario, carry out the following procedure:
Scenarios  Select the scenario  Setup  Touch
the selected scenario  Associated Groups
 Add  Deselect the groups to delete and Select the ones to associate  Options  Next  Set
the actuators in the desired state Next (saving the scenario with the new settings of all the actuators).
Group selection and deselection are identified by the icons  and  respectively.
The control panel confirms the operation carried out.
Note: Saving implies deleting the previous scenario.
6.6 Saving a scenario.
The menu enables saving the configured scenarios.
Scenarios  Select the scenario  Setup  Touch
the selected scenario  Save  Yes 
Set the actuators in the desired state  Next (saving the scenario with the new settings of all the
actuators)
Note: Saving implies deleting the previous scenario.
6.7 Deleting a scenario.
To delete a scenario, follow the procedure below:
Scenarios  Select the scenario to delete  Setup  Touch
Scenario  Yes
The control panel confirms the deletion has been completed.
56
the selected scenario  Remove
Events
7. EVENTS.
The Events menu enables implementing some advanced functions using the home automation system.
For example, it is possible to switch on the garden lights for a certain length of time, switch off all the lights in the
house on activating the alarm system when going out, activate a scenario when coming back in you deactivate
it, etc.
In addition it is possible to add time conditions to activate the events only in the desired time intervals and/or on
the occurrence of certain situations.
The structure of the event is composed of at most 2 inputs and 2 outputs that can be on/off functions (groups),
scenarios and conditions of the anti-theft system (for example on/off/alarm status).
In addition it is also possible to include a condition among the inputs and a condition that allows making the events
more flexible (for example it switches on garden watering at a set time only IF it is not raining, or it lowers the roller
shutters at a set time only IF it is dark).
The Events menu enables:
- stopping and restarting the selected event manually;
- controlling the users (outputs) associated with the event even if it is not active;
- changing the event on and/or off times;
- viewing the structure of the event.
7.1 Stopping or restarting an event.
The initial screen of the Events menu, which is accessed via the Main Menu, displays one of the created programs. For example
Events
Programme 01
Garden Sprinkler
enabled
Menu
Eventi
Programma 01
Annaffiatore Giardino
attivato
Touching
Touching
Setup
Menu
Setup
Fig. 19
displays
the information on the selected program (Inputs IN, Outputs OUT, Timing, Current Status, etc.).
Menu Setup
displays the options for managing the selected program:
- Stop Program to stop the currently active selected program.
- Activate Program Outputs to activate all the outputs associated with the selected program.
- Deactivate Program Outputs to deactivate all the outputs associated with the selected program.
When the event is stopped, the wording Stop Program is automatically replaced by Restart Program; therefore,
when you want to activate an event manually, simply repeat the procedure that has just been illustrated and touch
Restart Program.
The control panel will always display a message confirming the operation carried out.
57
Events
7.2 Changing the on/off times of an event.
Events  Setup  Select the event whose time you want to change  Program Settings  Timing
 Select the desired timing Next
• No timing.
Disables every type of timing (the event is not tied to schedules/times).
Next  Set no Clock among the Inputs and Outputs ?  Yes
Lastly confirm all the settings made by touching
Save.
• Weekly clock.
Enables, for every day of the week, setting activation of the event at intervals of 10 minutes (minimum time).
Select the desired day of the week.
Select ON or OFF with
respectively upwards or downwards; do a
to the right > or to the left
< to move along the axis of 24h in steps of 10 minutes; the histogram will be updated.
The ON option activates the program for 10 minutes while OFF deactivates it; repeat the procedure for all the time
slots to change, then confirm with Set.
Touching
C expands the previously made selection ON or OFF forwards or backwards.
Select another day of the week and proceed as above; using Copy from....., it is possible to assign the selected
day with the program of any other day of the week; then select the day to copy and touch
Next.
After programming, confirm the settings made with Set.
• Period clock
Enables activating and deactivating the event at most two times each day of the week setting the time in steps
of 1 minute.
Select the desired day of the week.
Set the time for starting and ending each of the 2 events or one only, touching
confirm with Set.
the corresponding item then
N.B.: To delete an event, set the end time so it coincides with or is prior to its starting time. Deleting event 1 also
deletes event 2.
The Copy from..... button enables copying the program of a day that has already been set onto another one to set;
the procedure is similar to the one used for the weekly clock.
After programming, confirm the settings made with Set.
58
Events
• Cyclical clock
Used to cyclically repeat the activation/deactivation (On-Off) of an event according to the set duration and independently of the day, date and time.
Touch
Duration ON [h: min]
Set the duration of ON choosing the values of hours and minutes, then confirm with Set.
In a similar manner set Duration OFF [h: min]
After programming, confirm the settings made with Set.
7.3 Renaming a program.
Events  Setup  Select the program to rename  Change Name
Scrolling through the list of characters displayed, do a
form the name; touch
to the right to insert the desired letters until you
59
Burglar alarm system
8. INTRUSION DETECTION ALARM SYSTEM.
The menu that manages the alarm system is called the SAI control panel and is active only if the By-me intrusion detection alarm system is also installed.
The system is managed according to "zones" and "partitions"; the zones are associated with the alarm sensors
(for example bedroom IR sensor, kitchen window contact, etc.) while a group of zones is called a "partition" (for
example all the contacts of the day zone, etc.).
The alarms displayed/signalled can be of different types:
- Intrusion alarm (intruders in the active zones of the system).
- Tamper alarm (tampering damaging the system devices).
- Technical alarm (for example water sensor, gas sensor, etc.). This is a type of alarm that does not activate the
sirens but generates the signals via GSM (if there is the communicator), it closes the solenoid valves, etc.
- No mains (with no mains power the battery powered back-up unit triggers to power the system).
Alarm System
SAI
on
OK
No Allarm
Menu Setup
Fig. 20
Main menu  Alarm System
The control panel's main screen (Fig. 20) displays the icons relating to the options most frequently used.
Antintrusione
Impianto
: deactivates
signalling the current alarm. This option is used to silence the sirens (if there is an alarm) or
attivato
OK
to reset Nessun
a previous
Allarmealarm.
Antintrusione
Menu Setup
Impianto
Notice: Stop
Alarm silences the sirens but does not deactivate the system.
attivato
OK
Allarme
•
:Nessun
displays
all the alarms recorded by the system; it is useful to check the alarms that have occurred.
Menu Setup
ntintrusione
Impianto
attivato •
: deactivates the system (when the system is deactivated the displayed icon is ON that, if selected, actintintrusione
OK
Impianto
vates
the
intrusion detection alarm system);
essun
Allarme
attivato
enuOKSetup
essun Allarme
•
: used to obtain a quick partitioning that will involve all the connectors (done by any user or connector).
enu Setup
•
This function is useful, for example, when you want to move about freely in a zone of the house even if the partitioning of which it is a part is active or to be able to leave a window open even if it is included in a zone to activate.
60
Burglar alarm system
Notice: The zones will stay off until they are next turned on via the same menu (so the associated sensors will
not protect the excluded zones).
If the system is activated while a sensor is detecting a movement or a contact (door/window) is open, the activation is blocked and the control panel will display the device and the zone that have prevented carrying out the
operation.
In case of alarm the control panel will display the screen of Fig. 21.
Alarm System
SAI
on
SAI Alarm
Menu Setup
Fig. 21
61
Power management
9. POWER MANAGEMENT.
The power management functions of the By-me system let you control the consumption of your system and see
both instantaneous values and historical values of the electrical and other (water, gas) measurements.
The functions are grouped into three main menus:
-L
oad control: via the load control module it enables monitoring the amount of mains power being consumed in
order to prevent the meter from being tripped due to overload and disconnecting the controlled loads according
to priority, if necessary.
- Measurement control: allows your installer to configure the measuring devices that will allow you to view data
on the touch screen or the Web Server.
- Alarm control: allows you to view/reset any alarms related to the controlled loads.
9.1 Load control.
For each user, you can set how to handle the load control by choosing from the following options:
• Auto OFF/ON: automatic load connection and disconnection depending on the amount of power consumed
and the group's priority
• Forced ON: load always on, irrespective of the input conditions.
• Forced OFF: load always off, irrespective of the input conditions.
For each load, you can from the control panel or touch screen select the Auto OFF/ON and Forced ON mode
setting; with the events programmes available on the control panel you can then set one or more loads in Forced
OFF mode (typically used to time the activation/deactivation of specific loads).
9.1.1 Displaying the level of power consumed.
With the control panel you can at any time view the instantaneous power consumed by the system. Furthermore,
if the system is also monitoring a production plant, the instantaneous power generated in the system will be
displayed.
Main Menu  Power management  Load control
Load control
Consumption:
Generation:
12:00
KW
10.2
10.2 KW
Setup
Back
Fig. 22
The control panel displays the power in kW; to display load status and modify operation, tap
62
Setup 
Power management
9.1.2 Load operation control.
The load control management mode can be decided for each group by selecting Automatic, Forced ON and
Forced OFF.
• Automatic: The load is disconnected automatically depending on the priority assigned and reconnected automatically when the power consumption falls below the set threshold.
• Forced ON: The power outlet is always supplied.
• Forced OFF: The power outlet is never supplied.
Tapping
Power management  Load control  Setup  Operation displays the state of the loads
and allows you to change their operation.
By selecting the desired load, it is possible to set the type of management to carry out (Automatic, Forced ON
and Forced OFF).
9.2 Alarm control.
With this menu you can view the alarms associated with each measuring group and if necessary reset the leakage
alarm on those devices that support it.
Main Menu  Power management  Alarm control  Select the desired load  Select
the device (for example Diagnostic smart relay)  Select the alarm  Reset
Tapping
Back
Back
Back
Alarm
control
Alarm
control
Alarm
control
--No
--No
group
--- No group
group
Stair
light
8080
light
80Stair
Stair
light
380
Washing
machine
380
Washing
machine
380
Washing
machine
381
Oven
381
Oven
381
Oven
Back
Back
Back
Associated
relay
Associated
relay
Associated
relay
0x2202
Smart
relay
0x2202
relay
0x2202Smart
Smart
relay
0x2205
Diagnostic
smart
0x2205
smart
relrel
0x2205Diagnostic
Diagnostic
smart
rel
Diagnostic
smart
realy
Diagnostic
smart
realy
Diagnostic
smart
realy
OKOK
Load
failure
Load
failure
OK
Load
failure
Current
leakage
Current
leakage
Current
leakage
Back
Back
Back
Back
Back
Back
Power
management
Power
management
Power
management
Load
control
Load
control
Load
control
Measurement
control
Measurement
control
Measurement
control
Alarm
control
Alarm
control
Alarm
control
Reset
Reset
Reset
Fig. 23
63
Cleaning the control panel
10. CLEANING THE CONTROL PANEL.
To clean the control panel use a soft, dry, lint-free cloth in order to avoid scratching the display.
It is recommended not to use any solvents and/or detergents.
See our website www.vimar.com.
64
CERTIFICATO DI GARANZIA N°
SISTEMA BY-ME
CERTIFICATO DI GARANZIA N°
N°
C.A.P.
Acconsento
Non Acconsento
Viale Vicenza, 14 - 36063 Marostica VI - Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188
Fax (Export) +39 0424 488 709
www.vimar.com
49400428E0 04 1506
VIMAR - Marostica - Italy

advertisement

Related manuals

advertisement

Languages

Only pages of the document in English were displayed