WHALE Gulper 320 Installation instructions
WHALE Gulper 320 is a high-capacity shower/galley waste and bilge pump designed for boats up to 12 meters. It can pump waste water from the shower tray/galley sink (either overboard or from a holding tank) or be used as a small bilge pump. The pump has a self-priming feature and can be mounted on a horizontal or vertical surface. It comes with an in-line fuse assembly for protection against system blockages and requires a minimum wire size of 1.5mm2 (16 AWG).
PDF
Document
Advertisement
Advertisement
Gulper 320 High Capacity Shower/Galley Waste and Bilge Pump Installation Guidelines for: Model Number BP2052 Gulper 320 (12 volts) BP2054 Gulper 320 (24 volts) This booklet should be read before installation 1 Pages Contents 3-4 English 5-6 French 7-8 Italian 9-10 Spanish 11-12 Swedish 13-14 German 15 Warranty 2 Gulper 320 High Capacity Shower/Galley Waste and Bilge Pump To the Fitter the screw that holds the clamping rings, and rotating the pump head. Once you have marked the position for the three mounting feet, drill pilot holes of 3.2mm (1/8"). Use the three No.8 self tappers and washers to secure the pump. Use 19mm (3/4") or 25mm (1”) smooth bore reinforced hose to connect to the pump. Ensure all relevant personnel read the points listed below and that a copy is passed on to the end user. To the User Read the points listed below before installation and use of equipment. Application The Gulper 320 self-priming pump has been specifically designed to pump waste water from the shower tray/galley sink, (either overboard or from a holding tank) or as a small bilge pump. Output capacity depends on installation and operating conditions. The polarity is indicated by coloured cable (Positive - red, Negative - black). The pump is protected against reverse polarity connection. Minimum wire size is 1.5mm2 (16 AWG). (Note: undersized wire reduces voltage under load at the pump, thus giving poor performance and potential motor failure). The in-line fuse assembly supplied (see details below) must be fitted to the positive side of the pump. Note: 1. If it is intended for use for any other purpose or with any other liquid, it is the user’s responsibility to ensure that the pump is suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used. 2. With all applications it is important that a system of safe working practice is applied to Installation, use and maintenance. 3. When used as a bilge pump users should be aware that capacity may not be sufficient to cope with rapid influx of water. 4. Suitable for a bilge pump for boats smaller than 12 metres/39.4 ft (designed to ISO15083). Purpose The purpose of this fuse is to protect the pump from serious damage in the event of system blockages, therefore please ensure all valves are fully open before operating the pump. Connection Instructions Insert this fuse assembly between the positive terminal on the pump and the positive feed wire. Note: 1. If the fuse blows check: a) all system valves/stop cocks are open. b) the inlet and outlet nipples are not blocked c) the remainder of the system is not blocked in any way. 2. Fuse rating for BP2052 (12v DC) pumps 10 amp automotive. Fuse rating for BP2054 (24v DC) pumps 5 amp automotive To control the pump an in-line switch should be fitted between the positive live terminal on the battery and the positive lead on the pump. If using an automatic switch (such as a float switch) an isolator switch should be fitted. Choose a position to mount the pump that is dry and away from casual water. The pump may be mounted on a horizontal or vertical surface. When mounted vertically ensure that the pump head is lower most (see diagram below). X The Gulper 320 is switched on by either a remote on/off switch or an automatic float switch. When used to drain a shower or galley, the flow rate should be sufficient to take away the waste faster than the delivery from either the shower or galley tap. When mounting, position the pump on the intended surface and work-out the best angles for the hose, then mark the 3 hole positions using the pump feet. The pump head may be rotated to suit the hose connections, this is done by loosening 3 in the grooves between the head & gear housing (failure to do this will cause the pump NOT to prime). Refit clamping rings and tighten screw. Dimensional drawing of Gulper 320 112 mm 156 mm 280 mm 198 mm The electric motor runs but no water is pumped ? Check: a) that inlet hose connection is airtight, free from blockages, and does not collapse. b) that the shower/sink drain is not clogged. c) that the valves in the pump are not blocked & are seating properly in the pump head. d) that the diaphragm has not split - replace if damaged. 63 mm Typical Installation as a High Capacity Grey Waste Pump Galley Sink Dishwasher Gulper 320 Shower tray Shower tray The motor will not operate ? Check: a) the isolator switch is on. b) there is 12/24 volts from the battery. c) the in-line fuse & ensure all electrical connections are tight and free from corrosion. (If fuse has blown check for debris in pump head and clean out if necessary. replace fuse and run pump - see previous page). Typical installation as a Remote Mounting bilge pump Gulper 320 Service Kits Before inspecting or replacing the diaphragm disconnect the electrical supply. The user must then remove the pump head clamping rings, this is done by unscrewing the clamping screw. This will release the pump head, and allow easy access to the valves & diaphragm. The diaphragm and valves should be checked for any excessive wear, damage or cracks. The valves should be replaced if necessary by replacing the pump head (service kit AK2050). If the diaphragm needs to be replaced, undo the nut in the centre of the diaphragm and remove the diaphragm plate & diaphragm. Note: The centre pin may be in one of several positions, this will not affect replacement of the diaphragm). When replacing the diaphragm this can be fitted either cup up or down. Replace clamping plate making sure the rounded edge faces the diaphragm, also ensure that the outer sealing edge of the diaphragm is located securely 4 Installation X 5 156 mm 280 mm 198 mm 63 mm Gulper 320 Gulper 320 Kits d'entretien X 156 mm 280 mm 198 mm 63 mm Gulper 320 Lavabo Lavastoviglie Gulper 320 156 mm 280 mm 198 mm 63 mm Gulper 320 10 X 156 mm 198 mm 63 mm Diskho Diskmaskin Gulper 320 Gulper 320 X 156 mm 63 mm 198 mm Gulper 320 14 EC Declaration of Conformity We hereby declare, under our sole responsibility, that the enclosed equipment complies with the provisions of the following EC Directives. Electromagnetic Compatibility Directive 2014/30/EU on the approximation of the laws of the Member States relating to electromagnetic compatibility. CE mark affixed: 26 June 2006 Standards applied: 2013/53/EU Recreational Craft Directive EN55014-1:2006 EMC Emissions EN55014-2:1997+ A2:2008 EMC Immunity The product also conforms to the following standards: EN28846:1993 Ignition Protection ISO 8849:2003 Electrically Operated Bilge Pumps ISO 15083: 2003 Bilge Pumping Systems ISO 10133: 2012 Extra-low Voltage d.c. Installations EN60335-1:2002 Safety of household and similar electrical appliances EN60335-2-41:2003 Particular requirements for pumps Name: Richard Bovill Function: Engineering Director 15 ©Copyright Whale 2019 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE® is a registered trademark of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale’s policy is one of continuous improvement and we reserve the right to change specifications without prior notice. Illustrations are for guidance purposes only. Neither the accuracy nor completeness of the information contained in this or any product literature is guaranteed by the Company and may be subject to change at its sole discretion. Munster Simms Engineering Ltd (Whale) 2 Enterprise Road, Bangor, Co Down, N.Ireland BT19 7TA Tel: +44 (0)28 9127 0531 Web: www.whalepumps.com Email [email protected] USA Support Tel: +1 616 897 9241 Web: www.whalepumps.com Email [email protected] 182.95 v7 1119 db">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement