Indel B TB55A, TB51A Navodila za uporabo
PDF
Dokument
Oglas
Oglas
INDEL B S.p.A. Via Sarsinate, 27 47866 S. Agata Feltria (RN) ITALY Tel.: +39 0541 848 711 - Fax: +39 0541 848 741 www.indelb.com [email protected] TB SERIES TB_SERIES_27-04-2018 380mm TB31A 350mm 585mm 350mm 585mm 350mm 585mm 445mm TB41A 530mm TB51A 189A0469 189A1183 CAVO DI COLLEGAMENTO IN AC TB_SERIES_27-04-2018 CAVO DI COLLEGAMENTO IN DC 1 TB SERIES ITALIANO TB45A 567 mm 475 mm 552 mm 470 mm 189A0666 TB55A 683 mm 678 mm 530 mm 515 mm 189A0669 189A0469 189A1183 CAVO DI COLLEGAMENTO IN AC 2 CAVO DI COLLEGAMENTO IN DC TB_SERIES_27-04-2018 TB SERIES ITALIANO DATI TECNICI MODELLO TB31A 380 x 350 x 585 16 Kg 30 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB41A 445 x 350 x 585 17 Kg 40 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB45A 470 x 552 (567 with hooks) x 475 19 Kg 45 L DC 12/24V & R134a 0,065 kg AC 100-240V (CO2 eq. 0,093 t) 50/60 Hz TB51A 530 x 350 x 585 18,5 Kg 50 L DC 12/24V & R134a 0,045 kg AC 100-240V (CO2 eq. 0,064 t) 50/60 Hz TB55A 22,5 Kg 55 L DC 12/24V & R134a 0,085 kg AC 100-240V (CO2 eq. 0,122 t) 50/60 Hz 3 4 TB_SERIES_27-04-2018 TB SERIES ITALIANO ALLACCIAMENTO DEL FRIGORIFERO IN UN VEICOLO TB45A-TB55A - TB31A-TB41A-TB51A TB_SERIES_27-04-2018 24V 2,5 (AWG 13) 2,5 (8 FT) 5 (16FT) 4 (AWG 11) 4 (13 FT) 8 (26 FT) 6 (AWG 9) 6 (20 FT) 12 (40 FT) 5 TB SERIES ITALIANO HIG HM ED DC 50HZ/60HZ 12 V/ 24 V FU SE 15 12 V/ 24 15 15A DC V W 15 LO TB31A-TB41A-TB51A 15 TB45A-TB55A 15 A 50 HZ /6 0H Z 189A0757 - Cut-out 12V Cut-in 12V Cut-in 24V LOW 9.6 10.9 21.3 22.7 MED 10.1 11.4 22.3 23.7 HIGH 11.1 12.4 24.3 25.7 6 TB_SERIES_27-04-2018 TB SERIES ITALIANO INSTALLAZIONE MANIGLIA (OPTIONAL) TB31A-TB41A-TB51A 3 1 2 4 3 4 TB_SERIES_27-04-2018 7 TB SERIES ITALIANO TEMPERATURE ECO MAX 189A0674 TEMPERATURE ECO MAX TB31A TB41A TB51A 189A0746 CONSIGLI UTILI TB_SERIES_27-04-2018 TB SERIES ITALIANO PULIZIA CONSIGLI UTILI E1 E2 E3 E4 E5 TB_SERIES_27-04-2018 9 TB SERIES ENGLISH Please read these instructions and the Safety section carefully before using your refrigerator. 380 mm 14,96 in TB31A 350 mm 13,78 in 585 mm 23,03 in 350 mm 13,78 in 585 mm 23,03 in 350 mm 13,78 in 585 mm 23,03 in 445 mm 17,52 in TB41A 530 mm 20,87 in TB51A 189A0469 189A1183 AC CONNECTION CABLE 10 DC CONNECTION CABLE TB_SERIES_27-04-2018 TB SERIES ENGLISH TB45A 567 mm (22,32 in) 475 mm 552 mm (18,70 in) (21,73 in) 470 mm (18,50 in) 189A0666 TB55A 683 mm (26,88 in) 678 mm (25,20 in) 530 mm (20,87 in) 189A0469 189A1183 AC CONNECTION CABLE TB_SERIES_27-04-2018 DC CONNECTION CABLE 11 TB SERIES ENGLISH TECHNICAL FEATURES MODEL Net weight Product class Voltage Refrigerant gas and charge TB31A 380 x 350 x 585 (mm) 16 Kg 14,96 x 13,78 x 23,03 (in) 35,27 lbs 30 L DC 12/24V & R134a 0,040 kg 1,059 ft3 AC 100-240V (CO2 eq. 0,057 t) 31,7 Quarts 50/60 Hz TB41A 445 x 350 x 585 (mm) 17 Kg 17,52 x 13,78 x 23,03 (in) 37,48 lbs 40 L DC 12/24V & R134a 0,040 kg 1,413 ft3 AC 100-240V (CO2 eq. 0,057 t) 42,3 Quarts 50/60 Hz TB45A 470 x 552 (567 with 45 L DC 12/24V & 19 Kg R134a 0,065 kg hooks) x 475 (mm) 1,589 ft3 AC 100-240V 41,89 lbs (CO2 eq. 0,093 t) 18,50 x 21,73 x 18,70 (in) 47,6 Quarts 50/60 Hz TB51A 530 x 350 x 585 (mm) 18,5 Kg 20,87 x 13,78 x 23,03 (in) 40,79 lbs TB55A 515 x 678 (683 with 55 L DC 12/24V & 22,5 Kg R134a 0,085 kg hooks) x 530 (mm) 1,942 ft3 AC 100-240V 49,60 lbs (CO2 eq. 0,122 t) 20,28 x 25,20 x 20,87 (in) 58,1 Quarts 50/60 Hz 50 L DC 12/24V & R134a 0,045 kg 1,766 ft3 AC 100-240V (CO2 eq. 0,064 t) 52,8 Quarts 50/60 Hz This appliance contains fluorinated greenhouse gas R134a within an hermetically sealed system and its operations depends on the presence of this gas. INSTRUCTIONS WARNING! Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. WARNING! Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. WARNING! Do not damage the refrigerant circuit. WARNING! Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer. WARNING! Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. WARNING! Risk of fire and electrical shock or fire. 12 TB_SERIES_27-04-2018 TB SERIES ENGLISH WARNING! Do not let hot items to touch the plastic parts of the appliance WARNING! Do not store flammable gas and liquid in the appliance. WARNING! Do not put flammable products or items that are wet with flammable products in, near or on the appliance. WARNING! Do not touch the compressor or the condenser. They are hot. Caution! • The cooler is suitable for cooling and freezing foods. • Use the travel box exclusively for cooling and storing closed beverages and snacks. • Do not store any perishable food in the travel box. • Food may only be stored in its original packaging or in suitable containers. • The travel box is not intended to be brought into contact with food. • The travel box is not intended for the proper storage of medicines. See the instructions in the package leaflet for the medicinal product. TB_SERIES_27-04-2018 13 INSTALLATION - Place the refrigerator on a dry, sheltered, flat surface and away from any edges. The refrigerator must not be used unsheltered, in the open air or exposed to splashing or rain. - Your refrigerator requires good ventilation, especially around the back of the refrigerator, allow a gap of at least 15 cm around the sides, back and top. Never use your refrigerator in the boot of a car or against. - Do not install the refrigerator near heat sources, sunlight. - Should you need to leave the device under the sun for long periods, eg. in a car or in other vehicles, make sure you protect it, to prevent the cover plastic materials from getting damaged or warped. - To fix it inside the car and to avoid damages during transport, we suggest to secure the fridge trough metal brackets placed on the sides - Avoid introducing liquids or ice not inserted in containers - Do not put hot food items into the refrigerator. - Avoid using the refrigerator under the rain or in presence of water. USING THE REFRIGERATOR IN A VEHICLE TB45A-TB55A - 14 TB31A-TB41A-TB51A Connect the feeding cable to a direct current 12 or 24 V DC power source. Make sure the polarity is right. The supply line is protected by a 15 A fuse located on the box. If connected to an existing cigarette plug, carefully check up that power supply is sufficient. If the supplied power cable is not used, see the table containing the information related to the cable section: CABLE AREA mm2 (AWG) MAX CABLE LENGHT METRES (ft) 12V 24V 2,5 (AWG 13) 2,5 (8 FT) 5 (16FT) 4 (AWG 11) 4 (13 FT) 8 (26 FT) 6 (AWG 9) 6 (20 FT) 12 (40 FT) TB_SERIES_27-04-2018 USING THE REFRIGERATOR AT HOME HIG HM ED DC 50HZ/60HZ 12 V/ 24 V FU SE 15 12 V/ 15 15A DC 24 V W 15 LO TB31A-TB41A-TB51A 15 TB45A-TB55A 15 A 50 HZ /6 0H Z 189A0757 - This model can be fed equally using 12/24V or mains power (100V - 240V AC). It is equipped with 2 sockets to connect the two different cables for DC respectively AC. The refrigerator is provided with automatic switch over from one kind of feeding to the other. Should both be present at the same time, the device will always set itself on mains power priority feeding by 100V~240V AC. ELECTRONIC CONTROL Compressor station Functions and features. This is an electronic device which has the function of piloting the motor of the compressor and carrying out all the controls and electrical protection of the system. Its main features are as follows: a) Protection of the battery through automatic turning off of the compressor when the feeding voltage reaches the minimum threshold. The compressor will start up again automatically when the voltage goes back to normal values. Note: these values have been measured at control unit input and/or on the DC socket. Battery protection Cut-out 12V Cut-in 12V Cut-in 24V LOW 9.6 10.9 21.3 22.7 MED 10.1 11.4 22.3 23.7 HIGH 11.1 12.4 24.3 25.7 (SWITCH POSITION) TB_SERIES_27-04-2018 15 HANDLE INSTALLATION (OPTIONAL) TB31A-TB41A-TB51A Handle kit The handle installation kit consists of: 1 - washer No. 4 pcs 2 - split spring washer No. 4 pcs 3 - round tubular component No. 1 pc 4 - stand No. 2 pcs 4 3 1 2 Kit mounting mount the stands (4) on the circular component (3) 4 3 4 Handle Installation Remove the screws (5) from the trunk. Fit washer (1) to the end of the handle (4). Insert the screw (5) on the handle (4) and at its end insert the split spring washer (2). Tighten the screws (5) to the trunk. 2 1 5 4 16 TB_SERIES_27-04-2018 USE TB45A TB55A ECO MAX TEMPERATURE ECO MAX 189A0674 TEMPERATURE ECO MAX TB31A TB41A TB51A 189A0746 - Plug in the DC or AC power. Press the button `ON/OFF` to run the refrigerator. The LED display on the control panel would be lighted and the interior temperature would be displayed. - Press the button and to adjust the temperature. Press the button to increase while the button to decrease the temperature. When press the above two buttons at the same time, it would switch the display between °C and °F. - Press the ECO key to enter the "ECONOMY" operating mode: the ECO light turns on and the compressor runs at minimum speed by keeping a fresh temperature inside the refrigerator. By pressing the ECO key again, the light turns off and the refrigerator enters in MAX mode (mode (maximum number of compressor turns). MAX light will be switched on until having achieved the temperature set. USEFUL ADVICE 1) Use the product in MAX mode in these cases: - use of the product as refrigerator with high ambient temperature; - when the suitable temperature need to be achieved in few time. 2) Use the product in ECO mode in these cases: - use of the product as refrigerator and, in particular, with low ambient temperature; - when the vehicle is parked for long time (with engine switched off) Do not put hot food items into the refrigerator. Place the products in such a way as to avoid them hitting against each other or breaking because of the movement of the vehicle. Make sure that the lid is always well closed and open it for as short a time as possible. Defrosting is needed when the layer of frost is thicker than 4 mm. To carry out this operation, turn off the refrigerator. Do not use sharp or cutting tools to remove the layer of frost or ice. Wait until complete unfreezing and then turn on again. TB_SERIES_27-04-2018 17 MAINTENANCE Before carrying out any maintenance operation on the refrigerator, take the power cable out of its socket. CLEANING • Regularly clean the inside and outside of the refrigerator using only warm water and a neutral detergent. • Subsequent to washing, rinse with clean water and dry thoroughly using a soft cloth. • Do not use the following: special glass and mirror cleaning products, liquid, powder, or spray detergents, alcohol, ammonia or abrasive products. • If you are not using the refrigerator, we suggest cleaning it well inside and leaving the door ajar to ventilate the interior. Should the device fail to work or work badly, before referring to our after-sales service, make sure that: a) the feeding voltage is not missing; b) the voltage is the same as the one shown on the plate; c) the connections and the polarities are right; d) the airing grids are not covered over; e) the refrigerator unit is not near any heat source; f) the fuse of the feeding line is not blown. The power supply cable must be replaced only by qualified technical personnel and in any case by an after sales service authorised by the Manufacturer.. Indel B is not liable in any way if you do not comply strictly with all the previsions in this manual. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. FAULTS Number of flashes 18 Error type E1 Battery protection cut-out (The voltage is outside the cut-out setting). E2 Fan over-current cut-out (The fan loads the electronic unit with more than 1Apeak). E3 Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)). E4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed 1,850 rpm). E5 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). TB_SERIES_27-04-2018 380mm TB31A 350mm 585mm 350mm 585mm 350mm 585mm 445mm TB41A 530mm TB51A 189A0469 189A1183 CABLE DE CONEXIÓN CA TB_SERIES_27-04-2018 CABLE DE CONEXIÓN CC 19 TB SERIES ESPAÑOL TB45A 567 mm 475 mm 552 mm 470 mm 189A0666 TB55A 683 mm 678 mm 530 mm 515 mm 189A0669 189A0469 189A1183 CABLE DE CONEXIÓN CA 20 CABLE DE CONEXIÓN CC TB_SERIES_27-04-2018 TB SERIES ESPAÑOL CARACTERÍSTICAS TÉCNICAS MODELO TB31A 380 x 350 x 585 16 Kg 30 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB41A 445 x 350 x 585 17 Kg 40 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB45A 470 x 552 (567 with hooks) x 475 19 Kg 45 L DC 12/24V & R134a 0,065 kg AC 100-240V (CO2 eq. 0,093 t) 50/60 Hz TB51A 530 x 350 x 585 18,5 Kg 50 L DC 12/24V & R134a 0,045 kg AC 100-240V (CO2 eq. 0,064 t) 50/60 Hz TB55A 22,5 Kg 55 L DC 12/24V & R134a 0,085 kg AC 100-240V (CO2 eq. 0,122 t) 50/60 Hz 21 22 TB_SERIES_27-04-2018 INSTALACIÓN USO DE LA NEVERA EN UN VEHÍCULO TB45A-TB55A - TB31A-TB41A-TB51A TB_SERIES_27-04-2018 LONGITUD MÁXIMA DEL CABLE- METROS (pies) 12V 24V 2,5 (AWG 13) 2,5 (8 FT) 5 (16FT) 4 (AWG 11) 4 (13 FT) 8 (26 FT) 6 (AWG 9) 6 (20 FT) 12 (40 FT) 23 HIG HM ED DC 50HZ/60HZ 12 V/ 24 V FU SE 15 12 V/ 24 15 15A DC V W 15 LO TB31A-TB41A-TB51A 15 TB45A-TB55A 15 A 50 HZ /6 0H Z 189A0757 - BAJO 9.6 10.9 21.3 22.7 MEDIO 10.1 11.4 22.3 23.7 ALTO 11.1 12.4 24.3 25.7 (POSICIÓN INTERRUPTOR) 24 TB_SERIES_27-04-2018 INSTALACIÓN DEL TIRADOR (OPCIONAL) TB31A-TB41A-TB51A 3 1 2 4 3 4 TB_SERIES_27-04-2018 25 USO TB45A TB55A ECO MAX TEMPERATURE ECO MAX 189A0674 TEMPERATURE ECO MAX TB31A TB41A TB51A 189A0746 CONSEJOS ÚTILES 26 TB_SERIES_27-04-2018 E1 E2 E3 E4 E5 TB_SERIES_27-04-2018 27 380mm TB31A 350mm 585mm 350mm 585mm 350mm 585mm 445mm TB41A 530mm TB51A 189A0469 189A1183 CABLE DE CONNEXION CA 28 CABLE DE CONNEXION CC TB_SERIES_27-04-2018 TB SERIES FRANÇAIS TB45A 567 mm 475 mm 552 mm 470 mm 189A0666 TB55A 683 mm 678 mm 530 mm 515 mm 189A0669 189A0469 189A1183 CABLE DE CONNEXION CA TB_SERIES_27-04-2018 CABLE DE CONNEXION CC 29 Poids net TB31A 380 x 350 x 585 16 Kg 30 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB41A 445 x 350 x 585 17 Kg 40 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB45A 19 Kg 45 L DC 12/24V & R134a 0,065 kg AC 100-240V (CO2 eq. 0,093 t) 50/60 Hz TB51A 530 x 350 x 585 18,5 Kg 50 L DC 12/24V & R134a 0,045 kg AC 100-240V (CO2 eq. 0,064 t) 50/60 Hz TB55A 515 x 678 (683 with hooks) x 530 22,5 Kg 55 L DC 12/24V & R134a 0,085 kg AC 100-240V (CO2 eq. 0,122 t) 50/60 Hz Tension TB_SERIES_27-04-2018 TB_SERIES_27-04-2018 31 INSTALLATION - 32 TB31A-TB41A-TB51A LONGUEUR MAX DU CABLE EN METRES (pieds) 12V 24V 2,5 (AWG 13) 2,5 (8 FT) 5 (16FT) 4 (AWG 11) 4 (13 FT) 8 (26 FT) 6 (AWG 9) 6 (20 FT) 12 (40 FT) TB_SERIES_27-04-2018 HIG HM ED DC 50HZ/60HZ 12 V/ 24 V FU SE 15 12 V/ 24 15 15A DC V W 15 LO TB31A-TB41A-TB51A 15 TB45A-TB55A 15 A 50 HZ /6 0H Z 189A0757 BASSE 9.6 10.9 21.3 22.7 MOYENNE 10.1 11.4 22.3 23.7 HAUTE 11.1 12.4 24.3 25.7 (POSITION INTERRUPTEUR) TB_SERIES_27-04-2018 33 INSTALLATION DE LA POIGNÉE (FACULTATIVE) TB31A-TB41A-TB51A 3 1 2 4 3 4 34 TB_SERIES_27-04-2018 UTILISATION TB45A TB55A ECO MAX TEMPERATURE ECO MAX 189A0674 TEMPERATURE ECO MAX TB31A TB41A TB51A 189A0746 CONSEILS PRATIQUES 35 NETTOYAGE 36 E1 E2 E3 E4 E5 TB_SERIES_27-04-2018 380mm TB31A 350mm 585mm 350mm 585mm 350mm 585mm 445mm TB41A 530mm TB51A 189A0469 189A1183 NETZKABEL TB_SERIES_27-04-2018 TB SERIES DEUTSCH TB45A 567 mm 475 mm 552 mm 470 mm 189A0666 TB55A 683 mm 678 mm 530 mm 515 mm 189A0669 189A0469 189A1183 NETZKABEL 38 TB_SERIES_27-04-2018 Kühlvolumen TB31A 380 x 350 x 585 16 Kg 30 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB41A 445 x 350 x 585 17 Kg 40 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB45A 470 x 552 (567 with hooks) x 475 19 Kg 45 L DC 12/24V & R134a 0,065 kg AC 100-240V (CO2 eq. 0,093 t) 50/60 Hz TB51A 530 x 350 x 585 18,5 Kg 50 L DC 12/24V & R134a 0,045 kg AC 100-240V (CO2 eq. 0,064 t) 50/60 Hz TB55A 515 x 678 (683 mit Haken) x 530 22,5 Kg 55 L DC 12/24V & R134a 0,085 kg AC 100-240V (CO2 eq. 0,122 t) 50/60 Hz 39 40 TB_SERIES_27-04-2018 INSTALLATION TB31A-TB41A-TB51A - KABELQUERSCHNITT mm2 (AWG) TB_SERIES_27-04-2018 24V 2,5 (AWG 13) 2,5 (8 FT) 5 (16FT) 4 (AWG 11) 4 (13 FT) 8 (26 FT) 6 (AWG 9) 6 (20 FT) 12 (40 FT) 41 HIG HM ED DC 50HZ/60HZ 12 V/ 24 V FU SE 15 12 V/ 24 15 15A DC V W 15 LO TB31A-TB41A-TB51A 15 TB45A-TB55A 15 A 50 HZ /6 0H Z 189A0757 - LOW 9.6 10.9 21.3 22.7 MED 10.1 11.4 22.3 23.7 HIGH 11.1 12.4 24.3 25.7 42 TB_SERIES_27-04-2018 GRIFF INSTALLIEREN (OPTIONAL) TB31A-TB41A-TB51A 3 1 2 4 3 4 TB_SERIES_27-04-2018 43 BEDIENUNGSHINWEISE TB45A TB55A ECO MAX TEMPERATURE ECO MAX 189A0674 TEMPERATURE ECO MAX TB31A TB41A TB51A 189A0746 HILFREICHE TIPPS TB_SERIES_27-04-2018 E1 E2 E3 E4 E5 TB_SERIES_27-04-2018 45 380mm TB31A 350mm 585mm 350mm 585mm 350mm 585mm 445mm TB41A 530mm TB51A 189A0469 189A1183 CABO DE ALIMENTAÇÃO CC TB_SERIES_27-04-2018 TB SERIES PORTUGUÊS TB45A 567 mm 475 mm 552 mm 470 mm 189A0666 TB55A 683 mm 678 mm 530 mm 515 mm 189A0669 189A0469 189A1183 TB_SERIES_27-04-2018 47 TB SERIES PORTUGUÊS CARACTERÍSTICAS TÉCNICAS MODELO TB31A 380 x 350 x 585 16 Kg 30 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB41A 445 x 350 x 585 17 Kg 40 L DC 12/24V & R134a 0,040 kg AC 100-240V (CO2 eq. 0,057 t) 50/60 Hz TB45A 470 x 552 (567 with hooks) x 475 19 Kg 45 L DC 12/24V & R134a 0,065 kg AC 100-240V (CO2 eq. 0,093 t) 50/60 Hz TB51A 530 x 350 x 585 18,5 Kg 50 L DC 12/24V & R134a 0,045 kg AC 100-240V (CO2 eq. 0,064 t) 50/60 Hz TB55A 22,5 Kg 55 L DC 12/24V & R134a 0,085 kg AC 100-240V (CO2 eq. 0,122 t) 50/60 Hz TB_SERIES_27-04-2018 TB_SERIES_27-04-2018 49 TB45A-TB55A - TB31A-TB41A-TB51A 50 24V 2,5 (AWG 13) 2,5 (8 FT) 5 (16FT) 4 (AWG 11) 4 (13 FT) 8 (26 FT) 6 (AWG 9) 6 (20 FT) 12 (40 FT) TB_SERIES_27-04-2018 HIG HM ED DC 50HZ/60HZ 12 V/ 24 V FU SE 15 12 V/ 24 15 15A DC V W 15 LO TB31A-TB41A-TB51A 15 TB45A-TB55A 15 A 50 HZ /6 0H Z 189A0757 A 12 V desliga A 12 V liga A 24 V desliga A 24 V liga BAIXO 9,6 10,9 21,3 22,7 MÉDIO 10,1 11,4 22,3 23,7 ALTO 11,1 12,4 24,3 25,7 TB_SERIES_27-04-2018 51 INSTALAÇÃO DA PEGA (OPCIONAL) TB31A-TB41A-TB51A 3 1 2 4 3 4 52 TB_SERIES_27-04-2018 UTILIZAÇÃO TB45A TB55A ECO MAX TEMPERATURE ECO MAX 189A0674 TEMPERATURE ECO MAX TB31A TB41A TB51A 189A0746 CONSELHOS ÚTEIS TB_SERIES_27-04-2018 53 54 E1 E2 E3 E4 E5 TB_SERIES_27-04-2018 TB31A TB41A TB51A 189A0469 189A1183 470 mm 552 mm 189A0666 TB55A 683 mm 678 mm 515 mm 530 mm 189A0669 189A0469 189A1183 56 TB31A 350 × 585 × 380 24/12فولت تيار مباشر -100 240فولت تيار متردد 60/50هرتز R134a 0,040 kg )(CO2 eq. 0,057 t TB41A 350 × 585 × 445 24/12فولت تيار مباشر -100 240فولت تيار متردد 60/50هرتز R134a 0,040 kg )(CO2 eq. 0,057 t TB45A 24/12فولت تيار مباشر -100 240فولت تيار متردد 60/50هرتز R134a 0,065 kg )(CO2 eq. 0,093 t TB51A 350 × 585 × 530 24/12فولت تيار مباشر -100 240فولت تيار متردد 60/50هرتز R134a 0,045 kg )(CO2 eq. 0,064 t TB55A 24/12فولت تيار مباشر -100 240فولت تيار متردد 60/50هرتز R134a 0,085 kg )(CO2 eq. 0,122 t 57 • • • • • • تنبيه 58 - - TB45A-TB55A TB31A-TB41A-TB51A - 59 )AWG 9( 6 50HZ/60HZ FUSE AC110-120V/220-240V V 50HZ/60HZ 24 SE 15 15 15A 15 DC12V/24V DC12V/24V 15A DC12V/24V 15 V 12 V/ 24 A Z HZ /6 0H 50 189A0757 - 9.6 10.9 21.3 22.7 10.1 11.4 22.3 23.7 11.1 12.4 24.3 25.7 60 DC12V/24V AC 11 012 0V /22 024 0V V/ FUSE AC110-120V/220-240V 15 12 15 W HM LOW HIGH MED HM 15 W TB31A-TB41A-TB51A 4 3 1 2 4 3 4 61 TEMPERATURE MAX 189A0674 TB31A TB41A TB51A TEMPERATURE MAX 189A0746 62 63 E1 E2 E3 E4 E5 TB SERIES 64 TB_SERIES_27-04-2018">
/
Prenesi
Samo prijazen opomnik. Dokument si lahko ogledate tukaj. Najpomembneje pa je, da ga je naša umetna inteligenca že prebrala. Lahko razloži zapletene stvari na preprost način, odgovori na vaša vprašanja v katerem koli jeziku in vam pomaga hitro krmariti tudi po najdaljših ali najbolj zapletenih dokumentih.
Oglas