The Center EHE0200361 RF Programmable Room Thermostat is a modern wireless programmable thermostat that communicates with the relay box on an 868MHz Radio Frequency band to control a single heating system component, such as a boiler, pump, or zone valve. The thermostat includes a large LCD display with backlighting, making it easy to use during daily operation. The RF link between the individual room thermostat and the relay box in system packs is pre-configured at the factory and should be installed at the same site, making the installation process easy and fast.

PDF
Document
Center EHE0200361 Installation Guide | Manualzz

Advertisement

Advertisement

50039990-011 A
Installation Guide

RF Programmable Room

Thermostat & Relay Box

This product has been designed with your

environment in mind!

Please respect this by disposing of all

packaging, used parts and eventually

the product itself in an environmentally

friendly manner.

The EHE0200361 is a modern wireless

programmable room thermostat. To improve

the ease of use, this product includes a

large LCD display with backlighting to assist

customers during daily use.

The room thermostat communicates with the

relay box on an 868MHz Radio Frequency

(RF) band to control a single heating system

component such as a boiler, pump or zone

valve. Neither product will communicate

with other RF products that use different

frequencies or communication protocols.

Note: The RF link between the individual

room thermostat and relay box in system

packs is pre-configured at the factory and

therefore SHOULD be installed at the same

site. This makes the installation process fast

and easy, but if products from individual

system packs are separated, or mixed with

other pre-configured system packs during

installations please refer to section

4.1 Binding / Rebinding Procedure
to bind
the desired units together and allow them to

communicate with each other.

Description
The Relay Box is a RF device. For the
best performance install in an open

space. Leave at least 30cm distance

from any metal objects including wall

boxes and boiler housing.

Do not mount on metal wall boxes.

EMC compliance considerations

Keep AC mains supply/load cables

separate from signal wiring.

Refer to Code of Practice standards

EN61000-5-1 and -2 for guidance.

NOTE:
The Relay Box contains
no user serviceable parts. It

should be opened and installed

by qualified installer only.

WARNING:
Electrostatic sensitive
device! Do not touch the circuit

board.

NOTE:
All wiring must be in accordance with IEE regulations
CAUTION
: Observe ambient temperature and current limits
(see the Relay Box wiring label)

Burner (direct control)

< 7mm Ø

= M3.5

= N°6

> 7mm Ø

b.

1.5-2.5mm²

6mm max.

Combi boiler

1

2

2

1

230V

50-60Hz
<5A
BDR91
A-B:5(3)A
A-C:5(3)A

Zone valve

BDR91
A-B:5(3)A
A-C:5(3)A

230V

50-60Hz
<5A
V4043H

BDR91
A-B:5(3)A
A-C:5(3)A

230V

50-60Hz
<5A
1

4
5
6

2
3 a.
Please follow the illustrations and information below in sequence to install the relay box and

room thermostat correctly. For applications other than gas boilers, enabling special features

and to see what other system options are available refer to section
4) Installer Mode.
1) Installing the Wireless System

1.1 Installing the Relay box

1.2 Installing the Room Thermostat

1.2.1 Power Up

STEP 1:
Installing the Batteries:
a.
Lift up the front cover of the thermostat to reveal the battery cover and product controls.
b.
Remove the battery cover by pressing down and sliding out.
c.
Insert the 2 x AA LR6 Alkaline Batteries supplied with the thermostat, ensuring the correct
orientation (see
‘Controls Layout’ in User Guide).
d.
After a short pause the thermostat will display information on the screen and is now ready
for use.

e.
Replace the battery cover by sliding it firmly back into the front of the thermostat.
1.2.2 RF Communication Check (Test Mode)

To check the RF communication, hold the room thermostat about 2-3 metres from the

installed relay box. Press the
OFF button, then press the and buttons together with the
button for 3 seconds. The unit will display ‘TEST TRANSMIT’ and it will send test signals

to the relay box, flashing the green LED on every 6 seconds (relay output will remain off) for a

maximum of 10 minutes. When the green LED flashes on every 6 seconds proceed to the

next step.

NOTE:
If the green LED is not switched at specified intervals, the red LED is flashing or if you
are installing a replacement relay box or room thermostat, follow the procedures described in

section
4.1 Binding / Rebinding Procedure.
STEP 2: Setting the Time

To set the Date and Time:

a.
Press the DAY button once and the ‘day indicator’ will begin to flash.
b
. Press the DAY button until the correct day is reached (Day 1 = Monday). Press the
button to confirm.

c
. Press either of the or buttons once to enter time setting mode. The LCD screen
flashes the time digits (when the unit is powered for the first time the display shows 12:00).

d
. Use the or buttons to set the correct time then press the button to confirm.
Each press of the buttons will change the time by one minute and holding them down will

change the time slowly at first and get progressively quicker.

Note:
If this mode is entered accidentally then press the AUTO, MAN or OFF buttons to exit.
1.2.3 Locating the Room Thermostat
While still in the Test Mode, as described in section 1.2.2, the room thermostat should be

located taking the following into consideration and reviewing the illustrations below:

1
. Find a suitable location where the signal transmission is reliable. Reliable transmission is
indicated when the relay box is flashing the green LED every 6 seconds. NOTE: The relay

box relay will be off.

2
. Install the room thermostat on the wall using the wall bracket as shown in the diagram
below.

3
. Exit the Test Mode by pressing the AUTO or OFF button.
2.1 Automatic Operation

The relay box receives the heat demand

(0-100%) signal from the room thermostat.

The room thermostat will display the
symbol
on the LCD display whenever more heat is

required. Depending on the demand the relay

box will switch the heating device on to match

the current requirements of the system.

The green LED indicates the status of the relay

output:

Green LED on = relay on

Green LED off = relay off

Installer Mode is used to alter the system settings for specific applications, to use the special

features of the room thermostat in a different way or to alter the factory preset parameters.

Parameters are divided into two groups:

- Category 1 parameters – Room Thermostat Setup

- Category 2 parameters – System Setup.

These are all listed in section
3.4 Installer Parameters Table.
2.2 Temporary Manual Override

Pressing the relay box button will override the current relay position. As soon as

the next signal is received from the room thermostat the relay box will return back

to automatic operation as the automatic control has higher priority than manual

operation.

2.3 Communications Loss

If the RF communication is lost for a period of 1 hour the red LED will illuminate to

indicate that no RF messages have been received during the last hour.

The relay box will also enter the failsafe mode as selected in
Installer Mode
(see section
3.2 Relay box Fail-Safe Mode Setup). To allow manual control
of the relay box output manual override is available in fail-safe mode. When RF

communication is restored the relay box will automatically return to normal operation.

You can now use the
USER GUIDE supplied with the room thermostat to
demonstrate how it works to the home owner.

1.3 System Check

Now a simple test can be completed to check the full system has been installed correctly:

1.
Press the OFF button.
2.
Check the boiler supply is on and check that the green LED on the relay box is off.
3.
Press the MAN button.
4.
Adjust the setpoint up to the maximum (35°C) by pressing the button. The boiler
should come on (green LED ON on relay box) after a few seconds and the
symbol
appears on the room thermostat LCD display.

5.
Press the OFF button. The boiler will go off (green LED OFF on relay box) after a few
seconds and the
symbol disappears.
6.
Check the system operation by alternately pressing the MAN and OFF buttons several
times, bearing in mind the switching delay referred to above.

Now, you should have completed the installation successfully - to begin operating at the

default factory settings press the AUTO button or press PROG to modify the built-in heating

program accordingly.

Wall bracket

The room thermostat should be installed in an open space for best

performance as it is a radio frequency device.

Leave at least 30cm distance from any metal objects including wall boxes and at least 1 metre from any other
electrical equipment eg. radio, TV, PC etc.

Do not mount onto metal wall boxes.

• It is recommended that the relay box is fully installed.

1.2m

1

2

3

2) Basic Operation of the System

3) Installer Mode

Relay box

Push button and

relay status LED’s
3.1 Entering the Installer Mode
1.
Press the OFF button.
2.
Press and hold the button and the two
PROGRAM
and buttons together.
3.
The unit will display the first parameter
of installer parameter group category 1

(from Parameter No. 1 to 20).

4.
Press the or button to change
the factory setting. The display will flash

indicating that a change has been made.

5.
Press the button to confirm the
change. The display will stop flashing.

6.
Press the button to go to the next
parameter.

7.
Press the PROGRAM button to go to
Installer parameter group category 2 (from

Parameter No. 1 to 5).

8.
To exit installer mode, press the AUTO,
MAN
or OFF button.
3.3 Using the Room Thermostat for Specific Applications

The RF room thermostat is a versatile controller that can be used to control many different

applications. For most typical applications, like wall-hung gas fired combination boiler control

or zone valve control, no adjustments from the factory settings are required. For other

applications, like controlling an oil burner, the best system performance can be achieved by

modifying selected parameters of the room thermostat in the Installer mode. The table below

lists the most common settings used for specific applications.

COPY

DAY

DATE/

DAY

1..4

AUTO

MAN

OFF

PROGRAM

MANAUTO

Mon
Tue Wed Thu Fri Sat Sun
COPY

DAY

DATE/

DAY

1..4

Mon
Tue Wed Thu Fri Sat Sun
AUTO

MAN

OFF

1
2
PROGRAM

1

2

2

3.2 Relay box Fail-Safe Mode Setup

The failsafe mode defines the relay box output relay status if the RF communication is lost

(e.g. when the room thermostat stops communicating due to discharged batteries). The

factory setting keeps the relay permanently off when communications is lost. If this factory

setting needs to be changed follow the instructions below:

1.
Enter Installer mode as described above.
2.
Press the button to enter category 2 parameters.
3.
Select the parameter 7:LC by pressing the button.
4.
Select the fail-safe mode by pressing or buttons:
0 - when RF communication is lost the relay will be held in
OFF position.
1 - when RF communication is lost the relay output will cycle at 20% on 80% off.

5.
Press the button to accept the change.
6.
Attach appropriate label to the relay box to indicate the selected fail-safe mode.
IMPORTANT:
To enable the frost protection when RF communication is lost, select the fail-safe
mode 1. For systems with separate frost protection thermostat or where frost protection is not

required select fail-safe mode 0.

Specific Application:
Setting: What to change:
Cycle/

Hour

Minimum ON

Time
Note: All parameters listed below belong to
category 2
- System Settings (see Installer
Parameters Table
)
HEATING
Gas Boiler
(<30kW)
6 1 No changes required
Oil Boiler
3 4 Set 1:Ot parameter to 4
Set 2:Cr parameter to 3

Thermal Actuator
12 1 Set 2:Cr parameter to 12
Zone Valve
6 1 No changes required
Parameter
Parameter
No.

Factory Default Setting
Optional Setting
Category 1 Parameters – Room Thermostat Settings

Display
Description Display Description
AM-PM / 24hr

Display
1:CL 24 24 hr clock display
format
12 12hr - AM/PM clock display format
Reset Time/ Temp

Program
2:rP 1 Time / Temp profile
set to factory default

Changes to 0 when

one of the time/temp

profiles are changed

0
Time / Temperature are as
programmed

To restore the factory profile set to 1

LCD Backlighting
5:bL 1 Backlighting Enabled 0 Backlighting Disabled
Upper Temp Limit
6:uL 35 35°C Upper Temp.
Limit
21 to
34
21°C to 34°C adjustment in 1°C
steps

Lower Temp Limit
7:LL 5 5°C Lower Temp.
Limit
5 to 21 6°C to 21°C adjustment in 1°C
steps

Temperature Offset
12:tO 0 No temperature offset -3 to
+3
-3°C to +3°C adjustment in 0.1°C
steps

Proportional Band

Width
13:Pb 1.5 Proportional band of
1.5 degrees
1.6 to
3.0
1.6°C to 3.0°C adjustment in 0.1°C
steps

Reset Parameters

to Factory Defaults
20:FS 1 All settings at factory
defaults

Changes to 0 when

one of the parameter

is changed

0
Settings are as modified above
To restore the factory profile set to 1

3.4 Installer Parameters Table

3.4.1 Category 1 - Room Thermostat Settings

Note:
Remember to always press the button to confirm that you want to store your new
Installer Set-Up setting. To exit the Installer Mode press the
AUTO or MAN button.
5
6
/

Advertisement

Key features

  • Wireless programmable thermostat

  • Large LCD display with backlighting

  • 868MHz Radio Frequency communication

  • Controls single heating system component

  • Pre-configured for easy installation

  • Binding/rebinding procedure for system configuration

  • Diagnostic mode for troubleshooting

Frequently asked questions

To bind or rebind the thermostat and relay box, follow the steps outlined in section 4.1 Binding / Rebinding Procedure in the Installation Guide.

Communication loss can be caused by several factors, including incorrect placement of the thermostat, interference from other electrical devices, or depleted batteries. Refer to the troubleshooting guide in section 5.1 of the Installation Guide for possible solutions.

If the relay box does not respond to setpoint changes, you may need to bind the thermostat and relay box. Reset the relay box and follow the binding procedure as described in section 4.1 of the Installation Guide.

The green LED on the relay box indicates the status of the relay output. A green LED indicates that the relay is on, and a green LED off indicates that the relay is off.