Allstar 3500 Installation and Owner's Manual

Allstar 3500 is a high-quality overhead garage door operator designed for residential use. It features a powerful motor, durable construction, and a variety of safety and convenience features. With its advanced technology, Allstar 3500 provides smooth, quiet operation and exceptional performance, making it an ideal choice for your home.

PDF
Document
Allstar 3500 Installation and Owner's Manual | Manualzz

Advertisement

Advertisement

1
INSTALLATION AND
OWNER’S MANUAL
As of date of manufacture,
meets all ANSI/UL 325
Safety Requirements for
Vehicular Garage Door
Operators
6000 SERIES
Residential Vehicular Garage Door Operator
MODELS: 6000, 6500, 6500-P & J6500
READ THIS MANUAL
CAREFULLY BEFORE
INSTALLATION OR USE
107063
Serial #:
Date Installed:
Your Dealer:
INSTALLER: Place this manual in the plastic envelope provided and permanently
attach to the wall near the pushbutton.
2
Product Features ................................................................................... 2
Component Identification/Tools Required ........................................... 4
Section A: Assembly Instructions ....................................................... 5
Section B: Installation Notes................................................................ 6
Section C: Installing the Operator ....................................................... 7
Identify Your Door Type ............................................................. 7
Mounting the Front Bracket ....................................................... 8
Mounting the Power Head.......................................................... 9
Door Arm Installation ............................................................... 10
Pushbutton Connection ........................................................... 11
Section D: Auxiliary Equipment ......................................................... 13
Installation of All-Clear ............................................................ 13
Installation of Radio Controls.................................................. 14
Installation of the Super Station .............................................. 15
Operating Parameters.......................................................................... 16
Section F: Operation and Adjustment Instructions .......................... 17
Safety Notes ............................................................................. 17
Testing the Sensitivity ............................................................. 18
Testing the Reversing System ................................................ 18
Testing the All-Clear................................................................. 19
Operating the Super Station .................................................... 19
Operator Wiring Diagram .................................................................... 20
Auxiliary Equipment Wiring Diagram ................................................. 21
Installation Checklist ........................................................................... 22
Troubleshooting Guide........................................................................ 23
TABLE OF CONTENTS
READ THESE STATEMENTS CAREFULLY AND FOLLOW THE
INSTRUCTIONS CLOSELY.
The Warning and Caution boxes throughout this manual are there to protect you and
your equipment. Pay close attention to these boxes as you follow the manual.
WARNING
Indicates a MECHANICAL
hazard of INJURY OR
DEATH. Gives instructions
to avoid the hazard.
CAUTION
Indicates a MECHANICAL hazard
of DAMAGE to your gate, gate
operator, or equipment. Gives
instructions to avoid the hazard.
Indicates an ELECTRICAL
hazard of INJURY OR
DEATH. Gives instructions
to avoid the hazard.
WARNING
Indicates an ELECTRICAL hazard
of DAMAGE to your gate, gate
operator, or equipment. Gives
instructions to avoid the hazard.
CAUTION
3
PRODUCT FEATURES
The purpose of this booklet is to provide assembly,
installation and operation information concerning the 6000
Series Residential Garage Door Openers and related Accessory
Products.
NOTICE
IT IS IMPORTANT THAT THIS INSTRUCTION
MANUAL BE READ AND UNDERSTOOD
COMPLETELY BEFORE INSTALLATION OR
OPERATION IS ATTEMPTED.
NOTICE
THE IMPORTANT SAFEGUARDS AND
INSTRUCTIONS IN THIS MANUAL CANNOT
COVER ALL POSSIBLE CONDITIONS AND
SITUATIONS WHICH MAY OCCUR DURING ITS
USE. IT MUST BE UNDERSTOOD THAT
COMMON SENSE AND CAUTION MUST BE
EXERCISED BY THE PERSON(S) INSTALLING,
MAINTAINING AND OPERATING THE
EQUIPMENT DESCRIBED HEREIN. DO NOT
USE THIS EQUIPMENT FOR ANY OTHER THAN
ITS INTENDED PURPOSE - OPERATING
OVERHEAD GARAGE DOORS.
STANDARD FEATURES:
Sensing System: A built-in sensing system detects
obstructions during door operation. If in the downward (close)
travel mode, the Opener will sense an obstruction and reverse
the direction of the door. In the open mode, the Opener will
stop. Since all doors are different, the Sensing System has
independent adjustments for customizing the level of force
required for the normal opening and closing of specified doors.
( Page 18)
Close Limit Switch: In winter months it's common for
small pieces of ice or packed snow to be trapped under the
door. Ground swelling can also effect the close limit setting of
the Opener. The 6000 Series Close Limit Switch overrides the
Sensing System during the last one inch of closing travel and
prevents the door from reversing if it encounters an obstruction
at this point.
Alternating Action Operation: The mechanical wall
pushbutton functions in an Open/Stop/Close/Stop & Reverse
mode in normal operation. (Page 16)
Emergency Release: A pull cord allows separation of the
drive mechanism and manual operation of the door when
desired, as in the event of a power failure. (Page 11)
Automatic Reconnection: Once power is restored, or
automatic operation of the door is again desired, initiating
operation in the normal manner (Push Button, Radio Control,
etc.) will effect automatic reconnection of the Emergency
Release Mechanism. (Page 11)
Connections For Continuously Monitored Auxiliary
Entrapment Protection Devices: The 6000 Series
All-Clear™ Photosystem (light beam across the door
opening) can be easily connected to the Opener. Control
circuitry monitors the device continuously for proper
operation. (Page 20) Consult the factory for
compatibility of other auxiliary entrapment protection
devices.
Constant Contact To Close: For utmost safety, the
standard operation mode requires constant contact on the
mechanical Push Button to close the door if an Auxiliary
Entrapment Protection Device (see above) IS NOT
installed or if the Device fails. In this mode of
operation, a Radio Transmitter cannot be used to close
the door. (Page 13 & 14)
Momentary Contact To Close: After installing an
All-Clear™ Photosystem Auxiliary Entrapment
Protection Device the close operation mode is
automatically converted to momentary contact of the
mechanical Push Button, and a portable Radio
Transmitter can be used to close the door. (PageZ16)
All-Clear™ Photosystem: An invisible infrared
beam of light guards the door opening and reverses a
downward moving door if the beam is broken by a
stationary or moving object. The 6000 Series motor
control circuitry constantly monitors the All-Clear
Photosystem for proper operation.
OPTIONAL FEATURES:
Digital Radio Controls: The 6000 Series Openers
covered in this Manual can be fitted with optional Radio
Controls. Up to 19,683 private codes can be easily
selected without use of tools. (PageZ15)
Super Station (Deluxe Wall Push Button): A
feature-packed accessory unit, the Super Station allows
access to all of the Opener's functions. Independent
Open, Close, and Stop buttons permits full control of the
door’s operation. The Opener's built-in light can be
turned on or off independent of door operation. A
Security Switch allows the Opener to be deactivated for
extended periods of time. A Security Disable switch is
provided if the garage door is the only entryway into the
garage. Lighted Push Buttons enhance nighttime use.
(Page 16)
Keyless Entry System: A tamper resistant outdoor
keypad, the optional Keyless Entry System permits entry
to the garage without use of key or radio transmitter.
Easily programmable, it accommodates four separate
access codes of 4 digits. Lighted Buttons enhance
nighttime use.
4
DOOR ARMS
DOOR MOUNTING
BRACKETS
SECTIONAL
DOORS
ONE-PIECE
DOORS
FRONT IDLER
TROLLEY
OUTER HALF
CHAIN
GUARD
WALL
MOUNTING
BRACKET
RELEASE ROPE
AND HANDLE
OPENER
HARDWARE
BAG
DRIVE
CHAIN
MASTER
LINKS
STEPLADDER
TAPE MEASURE
WOOD
BLOCK
HAMMER
TEE RAIL
HACKSAW
1/2” OPEN END
WRENCH
SOCKET WRENCH
3/8” SOCKET
7/16” SOCKET
LEVEL
DRILL
DRILL & BITS
RUBBER BUMPER
WALL PUSHBUTTON
!!!!
Child can be pinned under automatic garage
door. Death or serious injury can result.
• Never let child walk or run under moving door.
• Never let child use door opener controls.
• Always keep moving door in sight.
• If person is pinned, push control button or use
emergency release.
• Test door opener monthly:
Refer to your owner’s manual
Place one-inch object (or 2x4 laid flat) on floor.
If door fails to reverse on contact, adjust opener.
If opener still fails to reverse door, repair or replace opener.
W AR N I N G
PUSHBUTTON
“WARNING” LABEL
OPENER HEAD UNIT
SCREW DRIVER
SMALL SCREW DRIVER
(1/8” HEAD)
ALL-CLEAR HARDWARE
ALL-CLEAR
PHOTOSYSTEM
CHAIN LIMIT
CAM
COMPONENT IDENTIFICATION
TOOLS REQUIRED
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
/

Advertisement

Key features

  • Powerful motor for smooth and quiet operation

  • Durable construction for long-lasting performance

  • Entrapment protection devices for added safety

  • Constant Contact To Close for utmost safety

  • Momentary Contact To Close for convenience

  • All-Clear™ Photosystem for reliable obstruction detection

  • Sensing System for customizable force adjustment

  • Close Limit Switch for precise door positioning

  • Radio Transmitter compatibility for remote control

  • Easy installation and maintenance

Frequently asked questions

The Allstar 3500 features a variety of safety features, including entrapment protection devices, a constant contact to close feature, and an All-Clear™ Photosystem.

The Sensing System detects obstructions during door operation and adjusts the force required for opening and closing based on the specific door.

Yes, the Allstar 3500 is compatible with Radio Transmitters, allowing you to control the door remotely.

Preparing document for printing…
0%