The 9145E is a second generation Network Interface Device (NID) that can be used by a Service Provider (SP) to provide Layer 1 and Layer 2 termination of Ethernet services. This device comes in a variety of configurations to meet the needs of different applications. The 9145E offers features and functions that enable SPs to deliver Metro Ethernet Forum (MEF) compliant Ethernet services with end-to-end Quality of Service (QoS) guarantees and Operation, Administration, Maintenance and Provisioning (OAM&P) capabilities.

PDF
Document
9145E Ethernet Network Interface Device Hardware User's Manual | Manualzz

Advertisement

Advertisement

9145E
Ethernet Network
Interface Device
Hardware User’s Manual
NOTICE
Canoga Perkins has prepared this users manual for use by customers and Canoga Per-
kins personnel as a guide for the proper installation, operation and/or maintenance of
Canoga Perkins equipment. The drawings, specifications and information contained in
this document are the property of Canoga Perkins and any unauthorized use or disclo-
sure of such drawings, specifications and information is prohibited.
Canoga Perkins reserves the right to change or update the contents of this manual and
to change the specifications of its products at any time without prior notification. Every
effort has been made to keep the information in this document current and accurate as of
the date of publication or revision. However, no guarantee is given or implied that the
document is error free or that it is accurate with regard to any specification.
CANOGA PERKINS CORPORATION
20600 Prairie Street
Chatsworth, California 91311-6008
Business Phone: (818) 718-6300
(Monday through Friday 7 a.m. - 5 p.m. Pacific Time)
FAX: (818) 718-6312 (24 hrs.)
Web Site: www.canoga.com
E-mail: [email protected]
Copyright © 2004, 2005 Canoga Perkins Corporation
All Rights Reserved
EdgeAccess®
9145E Ethernet Network Interface Device
User Manual
Model Number 9145E
Part Number 6913650
Rev. A 04/2008
s2.1
TG
EdgeAccess and Canoga Perkins are registered trademarks of Canoga Perkins Corp.
To reference Technical Advisories and Product Release Notes, go to the Canoga Perkins
web site at http://www.canoga.com.
9145E Ethernet Network Interface Device User’s Manual
i
CAUTION!
This product may contain a laser diode emitter operating at a wavelength of 1300 nm - 1600 nm.
Use of optical instruments (for example: collimating optics) with this product may increase eye
hazard. Use of controls or adjustments or performing procedures other than those specified
herein may result in hazardous radiation exposure.
Under normal conditions, the radiation levels emitted by this product are under the Class 1 limits
in 21 CFR Chapter 1, Subchapter J.
ATTENTION!
Ce produit peut contenir un émetteur de diode de laser fonctionnant à une longueur d'onde 1300
de nm - nm 1600. Utilisation des instruments optiques (par exemple: la collimation du système
optique) avec ce produit peut augmenter le danger. L'utilisation des commandes ou des ajuste-
ments ou les procédures d'exécution autre que ceux indiquées ci-dessus peut avoir comme
conséquence l'exposition de la radiation dangereuse.
Dans des conditions normales, les niveaux de rayonnement émis par ce produit sont sous les
limites de la classe 1 en chapitre 1, Subchapter J de 21 CFR.
NOTICE!
This device contains static sensitive components. It should be handled only with proper Electros-
tatic Discharge (ESD) grounding procedures.
AVIS!
Ce dispositif contient les composants sensibles statiques. Il devrait être manipulé seulement
avec la Décharge Electrostatique (DES) appropriée procédures.
9145E Ethernet Network Interface Device User’s Manual
ii
General Safety Considerations
Installation
The 9145E is suitable for installation in Network telecommunication facilities and locations where
the National Electric Code (NEC) applies.
Cabling
The 9145E has been designed and tested and has passed all the pertinent sections of GR-1089
and GR-63 for Type 2 and Type 4 equipment. This equipment does not have direct electrical
connection to outside plant equipment.
The Copper (RJ45) ports of the 9145E are not intended for direct connection to “Outside Plant”
metallic conductors and shall be isolated (by channel banks or office repeaters) from any
connections to network or terminal equipment that lie outside of the same building. The telecom-
munication interface connections are considered to be, and meet the requirements of, SELV cir-
cuits (not TNV).
Power
WARNING: The 9145E with redundant power supplies must have both power supply cords
disconnected before servicing.
Wiring methods used for the connection of the equipment to the AC or DC MAINS SUPPLY shall
be in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical
Code, Part I, CSA C22.1.
The 9145E AC and DC units do not incorporate a disconnect device. The plug on the power sup-
ply cord is intended to serve as the disconnect device. It is also recommended that the AC soc-
ket-outlet shall be installed near the equipment and shall be easily accessible.
The 9145E DC has a nominal operating DC voltage of -48 VDC and passes the minimal steady
state DC operating voltage of -40 VDC in accordance with GR-1089 Issue 4 which References
American National Standards Institute (ANSI) T1.315, Table 1. Additionally, Canoga Perkins
design allows for a minimal steady state of -36VDC.
The 9145E DC model is configured for a DC-I, Isolated DC return.
Fuses
The 9145E is equipped with internal fuses. The AC model is fused at 2A and the DC at 1.5A.
Surge Protection
The AC powered 9145E does not contain an internal Surge Protective Device. An external Surge
Protective Device (SPD) should be used at the AC input of the network equipment according to
facilities procedures and as defined by the National Electric Code (NEC).
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
/

Advertisement

Key features

  • MEF compliant Ethernet services

  • QoS guarantees

  • OAM&P capabilities

  • Layer 1 and Layer 2 termination

  • SFP and UTP connectors

  • Single and redundant AC and DC power options

  • Remote management capabilities

  • Console port communication

  • ESD protection

Frequently asked questions

The 9145E is a Network Interface Device (NID) from Canoga Perkins that provides Layer 1 and Layer 2 termination of Ethernet services.

The 9145E offers single and redundant AC and DC power options, as well as a mix of AC and DC power.

The 9145E has both SFP and UTP connectors for Ethernet connectivity.

The 9145E can be remotely managed through an Ethernet management port and locally through a console port.

The 9145E incorporates safety features such as ESD protection and compliance with relevant safety standards.

The 9145E is used by Service Providers to deliver Ethernet services with QoS guarantees and OAM&P capabilities.

User questions

Z K

Linda Z.

What are the general power and amperage requirements for the 9145E device?

The device operates with 100 VAC to 240 VAC (auto-ranging), 50/60 Hz, 0.5 Amps, or 36 VDC to 72 VDC, 1.0 Amps.