Termination Clearances. Vermont Castings Stardance SDV30


Add to My manuals
44 Pages

advertisement

Termination Clearances. Vermont Castings Stardance SDV30 | Manualzz

Stardance Direct Vent/Natural Vent Gas Heater

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner Outside Corner Alcove Applications*

D

C

G

V

G =

Combustible

6" (152 mm)

Noncombustible

2" (51 mm)

V

F

F =

Combustible

6" (152 mm)

Noncombustible

2" (51 mm)

O

V

E

C

Balcony - with no side wall

Balcony - with perpendicular side wall

E = Min. 6” (152 mm) for non-vinyl sidewalls

Min. 12” (305 mm) for vinyl sidewalls

O = 8’ (2.4 m) Min.

M

V

M =

Combustible &

Noncombustible

12" (305 mm)

M

Combustible &

Noncombustible

M = 24" (610 mm)

P = 20” (508 mm)

V

P

No.

of Caps D

Min.

1

C

Max.

3’ (914 mm) 2 x D

2

3

4

6’ (1.8 m)

9’ (2.7 m)

1 x D

Actual

Actual

2/3 x D

12’ (3.7 m) 1/2 x D

Actual

Actual

D

Min.

C

Max.

= # of Termination caps x 3

= (2 / # termination caps) x D

Actual

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.

Fig. 10 Termination clearances.

584-15

Venting Requirements - Natural Vent Only

��

��

��

��

��

��

��

��

��

��

��

��

��

��

A

B

������������������������������������������������������

Horizontal Run (in feet)

Fig. 11 Vent termination window - Natural Vent ONLY.

20007065

Venting Runs

NOTE: When venting staight vertical, without any elbow, a minimum of 8 ft. vertical is required off the top of the stove.

= Acceptable venting configuration

= Unacceptable venting configuration

A: Vertical installations up to 36 feet (12m) in

height. Up to an 18 ft. horizontal vent run can be

installed within the vent system using a

maximum of two 90-degree elbows or four

45-degree elbows.

B: Vertical installations up to 36 feet (12m) in

height. Up to a 24 ft. horizontal vent run can be

installed within the vent system using a

maximum of two 45-degree elbows.

(Ratio = 2/3, Hor./Vert.)

NOTE: When using the FSDHAG, the restrictor plate supplied with the stove is not used.

FP567

NVBR/NVBC VENTING RUNS

11/12/97

11