DIAGNOSTIC: Automatic
Performs a five-minute automatic test with water functions to check major washer functions
(door can be open). Press the same button used in step 2 to advance through automatic test steps.
NOTE: Basket must be floating in order to agitate. Step C1 must be allowed to complete before advancing to step C5.
Two-Digit
Indicator
C0
C1
C2
C3
C4
Machine Function
Slow spin to 23 rpm.
Warm water fills through
Fresh and Detergent valves, then Fresh valve until basket floats
(disengages); then washer continues filling through Fresh and
Detergent valves to minimum water level.
Cold water fill through
Bleach valve for
10 seconds.
Hot water fill through
Fabric Softener valve for 10 seconds.
NOTE: Step will occur but no water can be dispensed with models that do not have a
fabric softener valve.
Warm water fill through
Detergent valve for
10 seconds.
C5
C6
Recirculate for
10 seconds.
C7
C8
C9
(none)
(Test ends)
Recommended Procedure
If no spin go to Manual: Motor,
Spin.
If no water or fill temperature is wrong, go to Manual: Water
Valves.
If basket does not float or disengage, determine cause of friction.
If no water in bleach cup go to
Manual: Water Valves.
If no water in fabric softener cup go to Manual: Water Valves.
If no water in detergent cup go to Manual: Water Valves.
Drain to basket engaged plus timed drain for
10 seconds.
Drain & slow spin
23 rpm.
Coast to 0 rpm.
End of cycle beep.
If water is not being re-circulated go to Manual: Pumps.
If water is not draining go to
Manual: Pumps.
If basket does not engage determine cause of friction.
If drain pump is not on go to
Manual: Pumps.
If basket is not turning go to
Manual: Motor.
If basket does not stop spinning within 5 seconds, press STOP and restart test.
If no end of cycle beep, make sure cycle signal is on. From Setting
Mode, pressing buttons should sound valid key press beep.
DIAGNOSTIC: Unsuccessful Entry
If entry into diagnostic mode is unsuccessful
(see steps 1 and 2 of Activation of Automatic
Diagnostic Test Mode), refer to the following indications and actions:
6-5
Indication 1: None of the indicators or display turns on.
Action: Press POWER button to enter setting mode.
•
•
If indicators come on, try to change the function for the button used to activate the diagnostic test mode. If that button fails to change the function, something is faulty with the button, and it is not possible to enter the diagnostic mode.
If no indicators come on after pressing
POWER button, go to TEST #1.
Indication 2: Fault code flashes from the display.
Action: Review the Display Fault/Error Codes table for the recommended procedure.
DIAGNOSTIC: Saved Fault Codes
If there are saved fault codes (as indicated in step 3 of Activation of Automatic Diagnostic
Test Mode), the most recent fault code will be displayed and alternately show “F” and “XX” where XX is the fault code, and all the cycle selector indicators flash.
Press and release the same button used to activate Diagnostics
Repeat
Repeat
Repeat
•
•
•
• Second most recent fault code is displayed.
Third most recent fault code is displayed.
Fourth most recent fault code is displayed.
All indicators momentarily turn off, then stay on. After 5 seconds, Automatic test cycle begins.
NOTE: Fault codes are retained.
ACTIVATION OF MANUAL
DIAGNOSTIC TEST MODE
1. Carefully read and perform steps 1 and 2 under Activation of Automatic Diagnostic
Test Mode, and press the same button once during the 5 second display time of the 88.
NOTE: If the button is not pressed within
5 seconds, the Automatic test will start
(after saved fault codes).