ALTERNATE ON/OFF SWITCH INSTALLATION FOR MILLIVOLT SYSTEMS

WIRING THE FIREPLACE

WARNING

Electrical wiring must be installed by a licensed electrician.

WARNING

DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT

FOR EXTENDED TIME PERIODS. THIS WILL PREVENT AC-

CIDENTAL FIREPLACE OPERATION.

Installation of Alternate Surround Panel ON/OFF Switch on the millivolt control valve only.

An ON/OFF switch and wire assembly are provided. They are included in the instruction packet.

Do not cut wire or insulation on metal edges.

Notice: Refer to surround panel installation section in the

Installation Instructions supplied with the surround for additional information on attachment.

DF(20,28)MBL or DF(20,28)LBL Surround

1. Find the coiled low voltage wire assembly and ON/OFF switch located in the instruction packet.

2. Attach the flag terminal ends to the “TH/TP” and “TH” terminals on the front terminal block of the gas valve. See Figure

19.

3. Run the low voltage alternate switch wires up the back of the right or left surround panel. Then secure the wires with wire clips provided. See Figure 18.

4. Remove the switch knockout on the DF(20,28)BL surround, then install the ON/OFF switch into the switch bracket.

5. Connect the low voltage wires from the gas valve to the

ON/OFF switch.

Note: The minimum clearance to the floor when using a

DF(20,28)MBL surround is 2 inches. This clearance allows access to the ON/OFF switch.

6. Attach the surround panel assembly to the insert. Place the surround panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides. Lift the surround panel assembly slightly until the bottom return flange (top panel) is positioned over the top flange on the insert. This secures the surround panel assembly to the insert without screws.

Figure 19

Figure 18 (DF20MBL Shown)

Insert ON/OFF switch into side panel then attach wire assembly from valve terminals.

Page 20 31385-6-0714

advertisement

Key Features

  • Variable flame height control for customized heat output
  • Built-in oxygen depletion sensor (ODS) for safety
  • Uses air (oxygen) from the room in which it is installed
  • No need for a chimney or flue
  • Can be installed in an aftermarket, permanently located, manufactured (mobile) home

Related manuals

Frequently Answers and Questions

What type of gas does the VFL20IN92(N,P)-1 use?
The VFL20IN92(N,P)-1 is designed to use natural gas.
What are the dimensions of the VFL20IN92(N,P)-1?
The VFL20IN92(N,P)-1 has overall dimensions of 20" W x 19" D x 23" H.
What is the BTU output of the VFL20IN92(N,P)-1?
The VFL20IN92(N,P)-1 has a BTU output of 20,000.
Does the VFL20IN92(N,P)-1 come with a remote control?
No, the VFL20IN92(N,P)-1 does not come with a remote control.
Can the VFL20IN92(N,P)-1 be used in a mobile home?
Yes, the VFL20IN92(N,P)-1 can be installed in an aftermarket, permanently located, manufactured (mobile) home.