Radiance Direct Vent Gas Heater
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
PILO
T
OFF
Fuel Conversion Instructions
Gas Supply Inlet
Main
Gas Line
ST226a
Fig. 60 Attach the gas line to the right side of the valve.
2. Allow the valve to cool to room temperature.
3. Remove the black protection cap by hand.
(Fig. 61)
Figure 61
��
4. Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (Fig. 62), rotate it counterclockwise until it is free and extract it.
�����
������������
����
��
Figure 63
5. Check that the screw is clean and if necessary remove dirt.
6. Flip the screw.
(Fig. 63)
��
��
7. Using the Allen wrench as shown in Figure 64, rotate the screw clockwise and tighten until snug.
WARNING: Do not overtighten the
Conversion Precautions
Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
Figure
62
Figure 64
�����
������������
����
��
��
��
�� short side.
����������
�����
������������
���� screw must be reassembled with the red o-ring visible. (Fig. 65)
Conversion Procedure
Figure 65
LP Configuration
Natural Gas
Configuration 1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 26, Fig. 46)
2. Undo the right and left latches at the top of the glass frame. (Page 26, Fig. 47)
3. Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel.
4. Remove the logset from the firebox.
Valve Conversion
RADVT Series Models
1. Turn control knob to the OFF position, and shut off the gas supply to the valve.
Red O-ring Visible
Red O-ring NOT Visible
9. Replace the black protection cap.
WARNING: Check that also the pilot and main burner injectors are appropriate for the gas type.
CO141 orifice.
��
�
6/07
��
�
CO141
20012697 37
Radiance Direct Vent Gas Heater
2. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 32,
Fig. 57)
3. Remove motor top cap using a standard slotted screwdriver. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 66)
Motor Top Cap
Center
Plunger
Valve PILO
T
•
OFF
O
N
Pilot Hood
Pilot
Bracket
Fig. 68 Remove pilot hood.
Index Tab
Blue - NG
Red - LP
FP1037b
Fig. 66 Depress and turn center plunger.
4. Insure manifold pressure remains between 3.2” - 3.5” w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a Torx #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP.
5. Replace motor top cap.
Pilot Orifice Conversion comfort valve convert
3/6/01 djt
1. Locate pilot. (Fig. 67)
Pilot
Allen Wrench
CO105a
LED
Snap Ring
CO105a gas conversion
Pilot
1/28/00 djt
CO106a
Fig. 69 Remove pilot orifice.
Pilot type 2 (Honeywell Pilot)
• Loosen pilot hood turning counterclockwise using a up.
CO106a
DV360/580
Pilot2
1/28/00 djt
Pilot Hood
ST916
Fig. 67 Locate pilot.
2. Replace pilot orifice.
Pilot Type 1 (SIT Pilot)
•
NOTE: It is not necessary to remove the pilot tube
•
Remove pilot hood by lifting up. (Fig. 68) Do not remove the snap ring to remove the pilot hood. for conversion.
Jefferson air shutter adj
Remove pilot orifice with Allen wrench. (Fig. 69)
• Install the conversion orifice.
• Reinstall pilot hood. Be sure to align hood with index tab.
Index
Marks
Pilot Bracket
CO143
Fig. 70 Remove pilot hood. (Your pilot may have a different appearance.)
• Remove pilot orifice with needlenose pliers. (Fig.
•
Rf pilot Conversion
Install the conversion orifice.
• Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket.
38 38 20012697
Radiance Direct Vent Gas Heater
3. Remove injector orifice from left burner bracket with a 1/2” wrench. Use a back up wrench to prevent damage to the manifold. (Fig. 74)
Pilot
Orifice
CO1044
Fig. 71 Remove pilot orifice.
Burner Orifice Conversion
1. Remove three (3) 3/8” nuts on bottom side of burner pan. (Fig. 72)
(Fig. 73)
CO144
RF Pilot conversion
CO145
Fig. 74 Use two wrenches to avoid damage to manifold.
4. Install conversion orifice. (Refer to Table 2)
5. The air shutter is factory set according to Table 3 and should not need adjustment. The air shutter
�����
Figure 75. ��������������
Orifice
Bracket
Air Shutter
Bottom View
Remove Nuts
ST918
Fig. 72 Remove three (3) nuts securing ember bed in place.
Orifice
Bracket
Venturi Bracket
�����
�����������
����
Pem Studs
ST919
Fig. 73 Tilt ember bed slightly to correctly place on venturi and air shutter.
�����
��������������
����
20012697
CO142
Fig. 75 The air shutter setting is 1/2” (13 mm) from the orifice bracket to the edge of the air shutter.
������
All Models
����������������
1. Replace burner making sure venturi on bottom of ember bed aligns with orifice and is seated properly on air shutter assembly. (Fig. 73) Make sure burner is slid into place at a slight angle and opposite to how it was removed. When burner is slid into place, the three (3) pem studs should slide down through clearance holes into the bottom of the control panel.
2. Thread and tighten 3/8” nuts back onto pem studs on underneath side of control panel, reversing Step
1 shown in Figure 72.
3. Reinstall logs as per instructions on Page 26.
4. Place conversion label on valve.
39
Radiance Direct Vent Gas Heater
5. Replace glass and stove front.
6. Restore gas to system and relight appliance according to Lighting Instructions on Page 31.
7. Leak check the system using a gas leak detector solution.
8. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation.
Conversion is complete.
Model
RADVT
RADVTC
Model
RADVT
RADVTC
Table 2. Injector Orifice Size Matrix
Conversion to LP
Kit # Orifice Part #
Input (BTU/h)
Minimum Maximum
25,000 36,000
20012729
20012900
Kit #
Conversion to Natural Gas
Orifice Part #
20012899
#31 / 0.120” 20006927
20012902
1.75 mm 20012946
Input (BTU/h)
Minimum Maximum
25,000 38,000
Table 3. Air Shutter Adjustment
Model
RADVT/RADVC
Natural Gas Natural Gas
High Altitude
1/2” Open 1/2” Open
LP
1/2” Open
Table 4. High Altitude Orifice
[Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)]
Input (BTU/h)
Model Orifice Part # Minimum Maximum
RADVT/RADVTC #33 / 0.113” 20012554 25,000 36,000
(Natural gas only)
*LP models do not need re-orificed up to 4500’ (1,370 m) above sea level.
40 40 20012697
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 General Information
- 4 Installation Requirements for the Commonwealth of Massachusetts
- 5 Stove Dimensions
- 6 Installation Requirements
- 6 Locating the Stove
- 6 Clearance Requirements
- 7 Parallel Installation
- 7 Corner Installation
- 7 Wall and Ceiling Clearances
- 7 Hearth Requirements
- 8 Gas Specifications
- 8 Gas Inlet and Manifold Pressures
- 8 High Elevations
- 8 Horizontal Termination
- 9 Vertical Termination
- 9 Restrictor Plate Adjustment for Extended Pipe Runs
- 10 Vent Termination Clearances
- 11 General Venting Information - Termination Location
- 12 Termination Clearances
- 13 Venting Requirements and Options
- 15 Tools Required
- 15 Parts Bag Contents
- 15 Unpack and Assemble Legs
- 16 Install Optional Fan
- 17 Venting System Assembly - Direct Vent
- 17 Install Vent Adapter Pipe (CFM Corporation Components)
- 17 Install Vent Adapter Pipe (Simpson Dura-Vent Components)
- 18 Install Vent Adapter Pipe (Selkirk Corporation Components)
- 18 Side Wall Termination Assembly
- 20 Vent Termination Below Grade
- 20 Vertical (Through the Roof) Vent Assembly
- 21 Selkirk Direct-Temp Metalbestos Direct Vent System
- 26 Install Log Set
- 28 Connect Gas Supply Line
- 28 Burner Information
- 29 Install ON/OFF Switch
- 29 Thermostat Connection (Optional)
- 29 Install the Mesh and Grille
- 29 Your First Fire
- 29 Pilot and Burner Inspection
- 30 Flame & Temperature Adjustment
- 30 Flame Characteristics
- 31 Lighting and Operating Instructions
- 32 Troubleshooting - SIT NOVA 820 (RADVT Series)
- 33 Instructions for RF Comfort Control Valve
- 37 Fuel Conversion Instructions
- 41 Annual System Inspection
- 41 Logset and Burner/Cleaning and Inspection
- 41 Care of Cast Iron
- 41 Cleaning the Glass
- 41 Glass Replacement
- 42 Gasket Replacement
- 42 Inspect the Vent System Annually
- 42 Check the Gas Flame Regularly
- 43 Wiring Diagrams