CIRCUIT CHECKS
HIGH VOLTAGE CHECK
CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below.
1. Connect an accurate high voltage meter to the anode of the picture tube.
2. Turn on the receiver. Set the BRIGHTNESS and CON-
TRAST to minimum (zero beam current).
3. High voltage must be measured below (B) kV.
Refer to table-1 for high voltage (B).
(See SETTING & ADJUSTING DATA on page 19)
4. Vary the BRIGHTNESS to both extremes to be sure the high voltage does not exceed the limit under any conditions.
CAUTION:
When the following parts fail, check the High Voltage after replacing.
Location
No.
T461
C407
C408
C441
C432
C433
Name
Flyback
Capacitor
Capacitor
Capacitor
Capacitor
Capacitor
Descriptions
50", 65"
TFB3092AD
4700pF,
±3%
8200pF, ±5%
4700pF, ±3%
8200pF, ±5%
1200pF, ±3%
FS CIRCUIT CHECK
The Fail Safe (FS) circuit check is indispensable for the final check in servicing. Checking should be done following the steps below.
1. Turn the receiver on.
2. Temporarily short TP- (R) and TP- (X) on the DEF/POWER
Board with a jumper wire.
Raster and sound will disappear.
3. The receiver must remain in this state even after removing the jumper wire. This is the evidence that the FS circuit is functioning properly.
4. To obtain a picture again, temporarily turn the receiver off and allow the FS circuit more than 5 seconds to reset. Then turn the receiver on to produce a normal picture.
Troubleshooting Guide for Fail Safe Circuit
Check that the set returns to normal operation when pin 12 of Z801 is grounded with jumper wire.
YES NO
Check the voltage across
Capacitor C419 is approximately ( C) volts.
Refer to table –3 for fall safe voltage ( C) .
YES
Faulty power circuit or horizontal circuit.
(See SETTING & ADJUSTING
DATA on page 19)
ANODE VOLTAGE MEASURING METHOD
CAUTION: Take extra precaution when measuring this high voltage. High voltages are also present in surrounding circuit boards (CRT DRIVE assembly, DEFLECTION assembly, and POWER
SUPPLY assembly).
1. Disconnect the FBT anode cable as outlined below. Measure high voltage at the point where the cable enters the
FBT.
2. Holding the rubber cover firmly, turn it counterclockwise and check that the lock has been disengaged. (See Fig. b on page 9.)
3. Determine the extent of the rubber cover before disconnecting the cable.
4. Pull straight up the anode cable to disconnect.
5. When reconnecting the cable, proceed in the reverse order.
After reconnecting, tug on the cable to check that it is secure.
Defective Fail Safe Circuit
NO
– 18 –
advertisement
Related manuals
advertisement
Table of contents
- 3 SAFETY INSTRUCTIONS
- 4 CRT ASSEMBLY REPLACEMENT AND MOUNTING
- 6 PICTURE TUBE COMPONENTS ADJUSTMENT
- 9 REPLACEMENT OF THE CRT
- 10 SERVICE MODE
- 12 ELECTRICAL ADJUSTMENT
- 14 CONVERGENCE ADJUSTMENT
- 17 SCREEN AND MIRROR ALIGNMENTS
- 18 CIRCUIT CHECKS
- 19 SETTING & ADJUSTING DATA
- 20 LOCATION OF CONTROLS (Representative: 50H82)
- 22 PROGRAMMING CHANNEL MEMORY
- 23 MECHANICAL DISASSEMBLY
- 25 CHASSIS REPLACEMENT PARTS LIST
- 45 PC BOARDS BOTTOM VIEW
- 55 TERMINAL VIEW OF TRANSISTORS
- 57 CIRCUIT BLOCK DIAGRAM
- 58 SPECIFICATIONS