Pre-Installation Preparation. Desa CD36M-A2, CD32M-1, CD32M-2, CD36M-A, CD42M-A2, CD36M-A1


Add to my manuals
24 Pages

advertisement

Pre-Installation Preparation. Desa CD36M-A2, CD32M-1, CD32M-2, CD36M-A, CD42M-A2, CD36M-A1 | Manualzz

SELECTING LOCATION

Continued

• Do not locate appliance close to where gasoline or other flammable liquids may be stored. The appliance must be kept clear and free from combustible materials.

• Do not use this appliance if any part has been under water. Immediately contact a local service technician to examine the appliance and to replace any part(s) of the control ignition system and other related components that have been submerged under water.

PRE-INSTALLATION

PREPARATION

CAUTION: Do not block required air spaces with insulation or any other material. Do not obstruct the effective opening of the appliance with any type of facing material.

CLEARANCES TO COMBUSTIBLES

Minimum clearances to combustibles for the fireplace are:

• Back and Sides of Fireplace . . . . . . . . . . . . 0"

• Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0"

• Perpendicular Wall . . . . . . . . . . . . . . . . . . . 6"

• Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36"

• Top of Standoffs . . . . . . . . . . . . . . . . . . . . . 0"

MANTEL CLEARANCES

Woodwork, such as wood trims, mantles and other combustible materials should be placed within the required clearance specified in Figure 2.

Mantel

Depth

(1) 14"

(2) 12"

(3) 10"

(4) 8"

(5) 6"

(6) 4"

(7) 2"

Mantel From Top of Opening

(A) 16"

(B) 14"

(C) 12"

(D) 10"

(E) 8"

(F) 6"

(G) 4"

A

B

C

D

E

F

G

1

2

3

4

5

6

7

Top of Louver Opening

Wall

Figure 2 - Mantel Clearances

4 www.desatech.com

111916-01F

PRE-INSTALLATION

PREPARATION

Continued

VENT TERMINATION CLEARANCES

The final position of your fireplace depends on the location of the vent termination in relation to the clearances that must be observed as shown in

Figure 5 on page 6.

The vent system serves as the “chimney” as well as the combustion air supply (air intake). The horizontal run must have a rise of 1/4" (.6 cm) for every 12" (30.48 cm) of horizontal run towards the termination. The maximum horizontal run depends on the vertical rise from the fireplace adapter collar to the vent termination (see table below).

VERTICAL

0 to

HORIZONTAL

1 ft (30.48 cm)

1 ft (30.48 cm) to 4 ft (121.92 cm)

2 ft (60.96 cm) to 8 ft (243.84 cm)

3 ft (91.44 cm) to 12 ft (365.76 cm)

4 ft (121.92 cm) to 16 ft (487.68 cm)

5 ft (152.40 cm) to 15 ft (457.20 cm)

6 ft (182.88 cm) to 14 ft (426.72 cm)

7 ft (213.36 cm) to 13 ft (396.24 cm)

8 ft (243.84 cm) to 12 ft (365.76 cm)

FRAMING

Once the final location has been determined, observing height clearances for vent termination, you may construct framing using dimensions shown in

Figures 3 and 4, depending on your installation.

If the appliance is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

A

B

C

CD32M CD36M-A CD42M-A

32 3 /

8

" 36 1 /

8

" 40 1 /

8

"

34 5 /

8

"

19"

41

23 1

1 /

4

/

2

"

" 48

25 5

1 /

4

/

8

"

"

B

A

C

Figure 3 - Framing Dimension

WARNING: Never allow the vent to run downward as this may cause excessive temperatures which could cause a fire.

A

B

D C

WARNING: Horizontal sections of this vent system require a minimum clearance of 2" from the top of the pipe and 1" minimum to the sides and bottom.

Vertical sections of this system require a minimum of 1" clearance to combustible materials on all sides of the pipe.

111916-01F

E

F

G

H

Nailing Tabs

CD32M CD36M-A CD42M-A

A 28 1 /

2

" 35 3 /

4

" 41 5 /

8

"

B 13 5 /

8

" 15" 21 5 /

8

"

C 39 3 /

8

"

D 9 1 /

2

"

49 5 /

8

"

10 3 /

8

"

58 1 /

2

"

13 1 /

2

"

E 9 7

F 34 1

/

8

"

/

2

"

13

41 1

3 /

4

/

8

"

" 16 3 /

4

"

48"

G 35 1 /

2

" 42 1 /

8

" 48 1 /

4

"

H 54 3 /

8

" 68 1 /

4

" 81 1 /

2

"

Figure 4 - Corner Installation www.desatech.com

5

6

PRE-INSTALLATION PREPARATION

Continued

N

N

D

H

E

V

B

L

C

Fixed

Closed

V

B

Openable Fixed

Closed

V

I

F V

Openable

B

G

B

B

V

A

J X G

M G

V

V K X V

A

V TERMINATION CAP X

A = clearance above grade, veranda, porch, deck, or balcony

[*12 inches (30.5cm) minimum]

B = clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches

(30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal

within a horizontal distance of 24 inches (61cm) from the

center-line of the terminal [18 inches (45.7cm) minimum]

E = clearance to unventilated soffit [12 inches (30.5cm) minimum]

F = clearance to outside corner (see below)

G = clearance to inside corner (see below)

H = *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

AIR SUPPLY INLET G GAS METER RESTRICTED AREA

(TERMINATION PROHIBITED)

I = clearance to service regulator vent outlet [*72 inches (182.9cm)

minimum]

J = clearance to non-mechanical air supply inlet to building or the

combustion air inlet to any other fireplace [*12 inches (30.5cm)

minimum]

K = clearance to a mechanical air supply inlet [*72 inches (182.9cm)

minimum]

L = † clearance above paved side-walk or a paved driveway located on

public property [*84 inches (213.4cm) minimum]

M = clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ‡]

N = clearance above a roof shall extend a minimum of 24 inches (61cm)

above the highest point when it passes through the roof surface and

any other obstruction within a horizontal distance of 18 inches (45.7cm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between two

single family dwellings and serves both dwellings*

‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*

* as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow

the current National Fuel Gas Code, ANSI Z223.1

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner Outside Corner Recessed Location

D

C C

A A = 6" (15.2cm)

E

V

V V

B B = 6" (15.2cm)

Balcony with No Side Wall Balcony with Perpendicular Side Wall

G

V

G = Combustible 24" (61cm)

Noncombustible 18" (45.7cm)

H

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

V

J

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location -

Combustible - 38" (96.5cm)

Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location-

Combustible - 6" (15.2cm)

Noncombustible - 2" (5.1cm)

Figure 5 - Minimum Clearances for Vent Terminations www.desatech.com

111916-01F