![Installing SAS controllers or controller enclosures. HP D3600 Enclosure | Manualzz Installing SAS controllers or controller enclosures. HP D3600 Enclosure | Manualzz](http://s1.manualzz.com/store/data/003221414_1-3195c5228c6c4069471be91c9936f9e2-360x466.png)
Installing SAS controllers or controller enclosures
When installing controllers or controller enclosures, be sure to do the following.
•
Record information about the controller or controller enclosure that will connect to the disk enclosure.
•
Depending on your deployment, do one of the following:
◦ For server connect deployments, install one or more Smart Array controllers in the server that will access the disk enclosure.
◦ For controller enclosure connect deployments, install or locate the controller enclosure to which the disk enclosure will connect.
NOTE: For detailed installation and configuration information about controller cards or controller enclosures, see the documentation provided with the controller card or controller enclosure.
Preparing the server
When preparing servers for the disk enclosure, be sure to do the following.
•
Record information about the server and environment (server connect or controller enclosure connect) that will connect to the disk enclosure.
•
Verify that the servers, controllers, operating system version, and service packs are supported for use with the disk enclosure. For more information, see the QuickSpecs for the disk enclosure, available on the D3000 website.
•
Install all operating-system-specific service packs, patch kits, or other required tools.
•
Install HP system management and monitoring tools, such as HP Systems Insight Manager
(HP-SIM) and the Array Configuration Utility (ACU).
NOTE: For detailed installation and configuration information about the server or the software tools, see the documentation provided with the server or software.
Installing SAS controllers or controller enclosures 31
advertisement
Related manuals
advertisement
Table of contents
- 7 Overview
- 7 D3600 Large Form Factor disk enclosure chassis
- 8 LFF Front view
- 8 Drive bay numbering
- 8 Rear view
- 9 D3700 Small Form Factor disk enclosure chassis
- 9 SFF Front view
- 10 Drive bay numbering
- 10 Rear view
- 11 Disk drives
- 11 Disk drive LEDs
- 11 Disk drive blanks
- 12 Front status and UID module
- 12 Front UID module LEDs
- 13 Unit identification (UID) button
- 13 Power supply module
- 13 Power supply module LED
- 14 Fan module
- 14 Fan module LEDs
- 15 I/O module
- 15 I/O module LEDs
- 16 Rear power and UID module
- 16 Unit identification (UID) button
- 16 Powering on
- 16 Cables
- 16 Cables to connect HP D3600/D3700 to any HP 6Gb SAS initiator
- 16 Cables to connect HP D3600/D3700 with any HP Smart Array 12Gb SAS initiator
- 17 Physical specifications
- 17 Power and environmental specifications
- 17 Acoustic noise levels
- 19 Installation overview
- 19 Required items
- 20 Preliminary tasks
- 20 Determining who will install and configure the disk enclosure
- 20 Confirming support for your hardware and software components
- 21 Signing up to automatically receive advisories, notices, and other messages
- 21 Confirming warranty support and finding out about related services
- 21 Gathering and recording information
- 21 Planning the storage configuration
- 22 System and performance expectations
- 22 Striping methods
- 22 RAID levels
- 23 Disk drive sizes and types
- 23 Spare disks
- 24 Array sizing
- 25 Preparing the site
- 26 Racking the disk enclosure
- 26 Rack installation best practices
- 26 Rack Installation procedures
- 29 Installing disk drives in the enclosure
- 29 Disk drive options
- 29 Disk drive guidelines
- 29 Installing a disk drive
- 31 Installing SAS controllers or controller enclosures
- 31 Preparing the server
- 32 Connecting SAS cables and power cords
- 32 Overview
- 32 Cabling best practices
- 33 Connecting SAS cables to the server or controller enclosure
- 34 Connecting SAS cables to cascaded disk enclosures
- 35 Connecting power cords
- 36 Powering on the disk enclosure
- 36 Power on best practices
- 36 Power on procedures
- 37 Verifying the operating status of the disk enclosures
- 38 Configuration overview
- 38 Supported software tools
- 39 Powering on disk enclosures
- 39 Power on procedures
- 39 Powering off disk enclosures
- 39 Updating disk enclosure firmware
- 42 Single-domain example
- 43 Dual domain example
- 44 If the enclosure does not initialize
- 44 Diagnostic steps
- 44 Is the enclosure front fault LED amber?
- 45 Is the enclosure rear fault LED amber?
- 45 Is the System Health LED amber?
- 45 Is the power supply LED amber?
- 45 Is the I/O module fault LED amber?
- 46 Is the fan LED amber?
- 47 Recognizing disk drive failure
- 47 Effects of a disk drive failure
- 47 Compromised fault tolerance
- 47 Factors to consider before replacing disk drives
- 48 Automatic data recovery (rebuild)
- 48 Time required for a rebuild
- 49 Failure of another drive during rebuild
- 49 Handling disk drive failures
- 50 Customer self repair (CSR)
- 50 Parts-only warranty service
- 50 Best practices for replacing hardware components
- 50 Verifying component failure
- 50 Identifying the spare part
- 50 Replaceable parts
- 51 Replacing the failed component
- 51 Replacement instructions
- 52 Hardware components
- 54 Contacting HP
- 54 Before you contact HP
- 54 HP contact information
- 54 Subscription service
- 54 Documentation feedback
- 55 Related information
- 55 Websites
- 55 Document conventions and symbols
- 55 Customer self repair
- 56 Rack stability
- 57 Regulatory compliance identification numbers
- 57 Federal Communications Commission notice
- 57 FCC rating label
- 57 Class A equipment
- 57 Modifications
- 57 Cables
- 58 Battery replacement notices
- 60 RoHS material content declarations
- 60 China RoHS material content declaration
- 60 India RoHS material content declaration
- 60 Turkey RoHS material content declaration
- 60 Ukraine RoHS material content declaration
- 60 Regulatory notices
- 60 Canadian notice (Avis Canadien)
- 60 Class A equipment
- 60 European Union notice
- 61 Japanese notices
- 61 VCCI-A notice
- 61 Japanese power cord statement
- 61 Korean notices
- 61 Class A equipment
- 61 Taiwanese notices
- 61 BSMI Class A notice
- 61 Chinese notice
- 62 Recycling notices
- 62 English notice
- 62 Bulgarian notice
- 62 Czech notice
- 62 Danish notice
- 62 Dutch notice
- 63 Estonian notice
- 63 Finnish notice
- 63 French notice
- 63 German notice
- 63 Greek notice
- 64 Hungarian notice
- 64 Italian notice
- 64 Latvian notice
- 64 Lithuanian notice
- 64 Polish notice
- 65 Portuguese notice
- 65 Romanian notice
- 65 Slovak notice
- 65 Spanish notice
- 65 Swedish notice
- 66 Turkish notice