advertisement
Figure 10: PCB View of Expansion Modules
24
DN2003-1202 v01.11
KT-400 Ethernet Four-Door Controller Installation Manual
Figure 11: Example of KT-400 Ethernet Four-Door Controller Interconnection with Expansion Modules
DN2003-1202 v01.11
25
Figure 12: Expansion Modules Cabinets for North America and European Union
26
DN2003-1202 v01.11
KT-400 Ethernet Four-Door Controller Installation Manual
Troubleshooting
Jumpers Heartbeats
Continuous quick flashing
3 short pulses
3 long pulses
Continuous long pulses
Table 3: Reset Types and Descriptions
Patterns Resets
Soft Reset:
When JP2 and JP3 are ON, the controller will reset on a) power up, b) pushbutton, or c) EntraPass software 'Manual operator soft reset':
• All controller's memory definitions and parameters are verified and kept intact if still valid.
• With a corporate gateway, the internal event buffer is maintained if still valid.
• With a global gateway, the internal event buffer is cleared.
• IP address is kept if valid.
• Controller generates the appropriate message: a) 'Power ON Soft Reset' b) 'Manual Pushbutton
Soft Reset' c) 'Operator Soft Reset'.
Hard Reset:
When JP2 is OFF and JP3 is ON:
• All controller's memory is settled to default values.
• Internal event buffer is cleared.
• IP address is kept if valid.
• Controller generates the message, 'Controller
Hard Reset'.
• Internal RTC (Real Time Clock) and clock are settled to the default time and date values
January 1st 2005, 00:00:00, Saturday.
Forced Default Static:
When JP2 is ON and JP3 is OFF:
• Same as 'Soft Reset' condition, except IP address is forced to the default static
IP: 192.168.1.2.
Factory Default DHCP:
When JP2 and JP3 are OFF:
• All controller's memory is settled to default values.
• Internal event buffer is cleared.
• Controller generates the message 'Controller
Factory Default Reset'.
• The Ethernet port reverts to DHCP configuration and waits for an IP address from the local DHCP server.
• Internal RTC and clock are settled to the default time and date values January 1st 2005,
00:00:00, Saturday.
DN2003-1202 v01.11
27
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 8 Pre-Installation Information
- 8 Copyright Information
- 8 Safety Instructions
- 9 Technical Support
- 10 Overview
- 10 Compatible with all EntraPass Special, Corporate and Global Editions
- 10 IP Devices
- 10 Four Onboard doors
- 10 Communication Ports
- 10 IP Connectivity
- 11 Inputs
- 11 Lock Outputs
- 11 Relay Outputs
- 11 Reader Outputs
- 11 Reader Interfaces
- 11 Elevator Interface
- 11 Alarm Panel Interface
- 11 Automatic Port Detection
- 12 Downloadable Firmware
- 12 Trouble and Reporting
- 12 Visual Status Indicators (LEDs)
- 12 Built-in SPI Expansion
- 16 System Architecture
- 19 Heartbeat LED Patterns
- 20 Technical Specifications
- 21 Electrical Specifications
- 21 Miscellaneous Items
- 23 Models Information
- 24 Installing the KT-400 Ethernet Four-Door Controller
- 24 Preparing to Install the KT-400 Ethernet Four-Door Controller
- 24 Physical Installation
- 24 Earth Grounding
- 24 Door Locking Devices
- 25 Hooking Up Inputs
- 25 Connect readers and keypads
- 26 Relay Controlled Outputs
- 26 Auxiliary Outputs
- 26 Tamper Protection
- 27 Connecting the KT-400 Ethernet Four-Door Controller
- 27 Connecting the VC-485 or the USB-485 to the RS-485 Bus
- 28 Connecting over Corporate Network (LAN)
- 28 Powering the KT-400 Ethernet Four-Door Controller
- 30 SPI Expansion Port
- 31 Important Installation Rules about Expansion Modules
- 35 Troubleshooting
- 36 Default Initialization
- 36 How to reset the KT-400 Ethernet Four-Door Controller for Factory Default DHCP mode
- 37 KT-400 Ethernet Four-Door Controller Maintenance Recommendations
- 38 Configuring the KT-400 Ethernet Four-Door Controller with the Web Configuration Page
- 38 Optional Documentation
- 39 Configuring the KT-400 Ethernet Four-Door Controller with the KT-Finder
- 43 Installation Checklist
- 44 Inputs and Outputs Assignments Sheet
- 46 Appendix A
- 46 Compliance Specifications
- 46 UL 294 Compliance Notice
- 46 UL 1076 Compliance Notice
- 47 FCC & IC