2 | CC880 Solution 16 Control Panel
Day Alarm
Day alarm monitors a group of zones when the system is disarmed. For example, the front door of a shop has a pressure mat or electronic beam that customers turn on as they enter or exit. The codepad beeps each time the mat or beam turns on.
Duress Alarm
A codepad duress alarm can work as a silent hold-up alarm and is useful when the system reports to a monitoring station or pocket pager.
Codepad Tamper Alarm
Codepad tamper limits the number of times that someone can try to enter the wrong user code. When someone exceeds the limit, the system starts an alarm and sends a report to a security monitoring station.
Telephone Line Fault Monitor Option
The optional CC887 Telephone Line Fault Module creates a telephone line fault when a telephone line fails. Users can program the system to sound an alarm if the telephone line is cut while the control panel is armed.
Automatic Battery Testing
The system performs a battery test each time a user arms the system, and automatically every four hours. When the system detects a low capacity back-up battery, it creates a low battery fault.
Event Memory Recall
Event Memory Recall plays the last 40 system events, including all alarms, system arming, and system disarming.
If the control panel is partitioned, Event Memory Recall plays the last 10 system events.
End-Of-Line (EOL) Resistor Value Choice
Users can choose from different EOL resistor values when programming the control panel. The selected value applies to all eight programmable zones at once. Users can add a control panel into an existing system without changing the
EOL resistors.
For 16 zones, use zone doubling or add an eight zone expansion board. With zone doubling, zones one to eight are 3 K3, and zones nine to 16 are 6 K8. The CC883 Eight
Zone Expansion Board supports adjustable EOL resistor values.
Functions for CC880 Models
Call Forwarding
The telecommunications provider must offer a call forwarding option. Users can program call forwarding modes to operate when the system is armed in the AWAY
Mode.
Call Forward Modes
• Immediate On: Redirects all incoming calls to another number, including mobile phones, pagers, and answering services. The telephone called first does not ring.
•
No Answer: Redirects all incoming calls to another number when the telephone that was called first is not answered within 20 seconds. Outgoing calls can still be made from the first telephone.
Functions for CC880PSP Models
Programmable Ring Burst Time
Telephone ring times might be longer or shorter depending on the technology in a system. Different timing can cause control panels to answer calls that should answered by an answering machine, fax, or a person. Users can program the control panel for the correct ring burst time. Adjust the ring time from 0 ms to 1200 ms in 5 ms increments.
Certifications and Approvals
Region
Europe
Certification
CE
A-Tick Supplier Code
New Zealand Telepermit
N663
PTC 211/95/246
Installation/Configuration Notes
Compatibility Information
RF Receivers RE005E RF Receiver with Outputs
RF Transmitters RE012E Two-channel Hand-held Transmitter
RE013E Four-channel Hand-held Transmitter
Codepads • CP105A Night Arm Station
CP500AW LED Area Addressable
• CP500ALW LCD Area Addressable
CP500PW LED Partitionable
• CP516LW LCD
CP516W LED
Modules MO144 Universal Timer Module
Technical Specifications
Enclosure
Dimensions (case, packed in carton):
Weight:
Environmental Considerations
Relative Humidity:
Temperature Range:
30.6 cm x 26.2 cm x 8.4 cm
(12 in. x 10.3 in. x 3.3 in.)
2.5 kg (5.5 lb)
10% to 95% non-condensing
0°C to +45°C (+32°F to +113°F)