Warranty. Eaton 700VA, 1500VA, 1000VA, RT 2000VA, RT 3000VA
Add to my manuals
19 Pages
Eaton 700VA is designed to back up the computer or sensitive electronics during a power outage. Connected equipment will receive consistent and clean power while avoiding damage from power surges. The device also safeguards against voltage fluctuations, brownouts, and other power irregularities.
advertisement
9. Warranty
Warranty on this product is valid against defects in material and workmanship for a period of 24 months from its original date of purchase.
10. Technical Specifications
10.1 Power Range 700-3000 VA (LV)
GENERAL
Rated power
Technology
700VA, 1000 VA, 1500 VA, 2000 VA, 3000 VA at p.f 0.7
On-line, double conversion topology with automatic bypass
INPUT
Phase:
Bypass Voltage
Input Voltage range:
Input Power factor:
Single phase with ground
96--138 VAC (user selectable)
60/70/80VAC-144 VAC
Frequency: 50/60 Hz. Auto selection
Frequency window from mains 45-65 Hz
Synchronization window
Input current
± 3Hz.
700 VA 5.8A, 1000 VA 8.2A, 1500 VA 12.4A, 2000 VA 16.5A
3000 VA 24.7A
0.97
OUTPUT
Output Voltage:
Voltage regulation:
Voltage distortion:
100/110/115/120/127 VAC, selectable from LCD panel
± 2%
< 5% THD at full non-linear load, < 3% THD at full linear load
Frequency regulation ± 0.25 Hz (battery or free running mode)
* 60V at 40% load, 70V at 70%, 80V at 100%.
10.2 Power Range 700-3000 VA (HV)
GENERAL
Rated power
Technology
700VA, 1000 VA, 1500 VA, 2000 VA, 3000 VA at p.f 0.7
On-line, double conversion topology with automatic bypass
INPUT
Phase
Bypass Voltage:
Input Voltage range:
Frequency:
Single phase with ground
184-265 VAC (user selectable)
120/140/160 VAC-276 VAC
50/60 Hz. Auto selection
Frequency window from mains 45-65 Hz
Synchronization window ± 2.5Hz.
Input current 700 VA 3A, 1000 VA 4A, 1500 VA 5.7A, 2000 VA 7.7A, 3000 VA
12A
Input Power factor: 0.97
28
OUTPUT
Output Voltage:
Voltage regulation:
Voltage distortion:
208/220/230/240 VAC, selectable from LCD panel
± 2%
< 5% THD at full non-linear load, < 3% THD at full linear load
Frequency regulation ± 0.25 Hz (battery or free running mode)
* 120V at 40% load, 140V at 70%, 160V at 100%.
Dynamic response:
Overload capacity:
± 9 % max from 100% to 20 % or from 20% to 100 % linear load
100-125% 1 min, 125-150% 10 sec
Efficiency: greater than 86%
10.3 Power Range 700-3000 VA (19” Rack-mount model)
GENERAL
Rated power
Technology
INPUT
Phase
Bypass Voltage:
Input Voltage range:
Frequency:
Single phase with ground
184-265 VAC (user selectable)
120/140/160 VAC-276 VAC
50/60 Hz. Auto selection
Frequency window from mains 45-65 Hz
Synchronization window ± 3Hz.
Input current 700 VA 3A, 1000 VA 4A, 1500 VA 5.7A, 2000 VA 7.7A, 3000 VA
12A
Input Power factor: 0.97
OUTPUT
700VA, 1000 VA, 1500 VA, 2000 VA, 3000 VA at p.f 0.7
On-line, double conversion topology with automatic bypass
Output Voltage:
Voltage regulation:
Voltage distortion:
Frequency regulation
208/220/230/240 VAC, selectable from LCD panel
± 2%
< 5% THD at full non-linear load, < 3% THD at full linear load
± 0.25 Hz (battery or free running mode)
* 120V at 40% load, 140V at 70%, 160V at 100%.
Dynamic response: ± 9 % max from 100% to 20 % or from 20% to 100 % linear load
Overload capacity:
Efficiency:
100-125% 1 min, 125-150% 10 sec greater than 86%
ENVIRONMENTAL
Ambient temperature:
Recommended temperature:
Storage temperature:
+0 °C to +40 °C
+15 °C to +25 °C
-15 °C to +50 °C
Audible noise: < 45 db normal and battery mode (700-1000 VA)
< 50 db normal and battery mode (1500-3000 VA)
29
STANDARDS
Safety:
Emissions:
Immunity:
HV Model
EN50091-1-1
EN50091-2
EN50091-2 B(700-1500VA), A (2K/3KVA)
OUTPUT
POWER
Connection
Input
700VA/490 W 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W
IEC 320 (10A) IEC 320 (10A) IEC 320 (10A) IEC 320 (10A) IEC 320 (16A)
Connection
Output
4 x IEC 320
(10A)
4 x IEC 320
(10A)
4 x IEC 320
(10A)
8 x IEC 320
(10A), 1 x IEC
320 (16A)
8 x IEC 320
(10A), 1 x IEC
320 (16A)
4 x 5-15R (US) 4 x 5-15R (US) 4 x 5-15R (US) 12 x 5-15R (US) 12 x 5-15R (US)
2 x Europe 2 x Europe 2 x Europe
6 x Europe, 1 x
IEC 320 (16A)
6 x Europe, 1 x
IEC 320 (16A)
Battery type
Lead-acid
7.2Ah/12V
Number of batteries
Backup time/full load
Recharge time
Dimensions
W x D x H mm
Lead-acid
7.2Ah/12V
Lead-acid
9Ah/12V
Lead-acid
7.2Ah/12V
Lead-acid
9Ah/12V
2 3 3 6 6
5 min 6 min 5 min 6 min 5 min
<4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90%
152 x 420 x 238 152 x 420 x 238 152 x 420 x 238 225 x 425 x 360 225 x 425 x 360
19” Rack-mount Model (2U)
OUTPUT
POWER
Connection
Input
700VA/490 W 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W
IEC 320 (10A) IEC 320 (10A) IEC 320 (10A) IEC 320 (10A) IEC 320 (16A)
Connection
Output
Battery type
Number of batteries
Backup time/full load
Recharge time
4 x IEC 320
(10A)
4 x IEC 320
(10A)
4 x IEC 320
(10A)
8 x IEC 320
(10A), 1 x IEC
320 (16A)
8 x IEC 320
(10A), 1 x IEC
320 (16A)
4 x 5-15R (US) 4 x 5-15R (US) 4 x 5-15R (US) 12 x 5-15R (US) 12 x 5-15R (US)
2 x Europe
Lead-acid
7.2Ah/12V
2 x Europe
Lead-acid
7.2Ah/12V
2 x Europe
Lead-acid
9Ah/12V
6 x Europe, 1 x
IEC 320 (16A)
Lead-acid
7.2Ah/12V
6 x Europe, 1 x
IEC 320 (16A)
Lead-acid
9Ah/12V
2 3 3 6 6
5 min 6 min 5 min 6 min 5 min
<4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90%
30
Dimensions
W x D x H mm
428 x 425 x 84 428 x 425 x 84 428 x 425 x 84 428 x 610 x 84 428 x 610 x 84
19” Rack-mount Model (1U)
OUTPUT POWER
Connection Input
Connection Output
Battery type
Number of batteries
Backup time/ full load
Recharge time
Dimensions W x D x H mm
Weight kg
700VA/ 490 W
IEC 320 (10A)
4 x IEC 320 (10A)
3 x 5-15R (US)
Lead-acid 7 Ah/ 6V
4
6 min
<4 hours to 90%
428 x 525 x 44
15.5
1000VA/ 700W
IEC 320 (10A)
4 x IEC 320 (10A)
3 x 5-15R (US)
Lead-acid 7 Ah/ 6V
4
4 min
<4 hours to 90%
428 x 525 x 44
15.5
LV Model
OUTPUT
POWER
Connection
Input
Connection
Output
Battery type
Number of batteries
700VA/490 W
Attached power cord
6 x 5-15R (US)
Lead-acid
7.2Ah/12V
1000VA/700W
6 x 5-15R (US)
Lead-acid
7.2Ah/12V
1500VA/1050W 2000VA/1400W 3000VA/2100W
6 x 5-15R (US)
Lead-acid
9Ah/12V
12 x 5-15R (US) 12 x 5-15R (US)
Lead-acid
7.2Ah/12V
Lead-acid
9Ah/12V
2 3 3 6 6
Backup time/full load
Recharge time
Dimensions
W x D x H mm
5 min 6 min 5 min 6 min 5 min
<4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90%
152 x 420 x 238 152 x 420 x 238 152 x 420 x 238 225 x 425 x 360 225 x 425 x 360
19” Rack-mount Model (2U)
OUTPUT
POWER
Connection
Input
700VA/490 W 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W
Attached power cord
31
Connection
Output
Battery type
Number of batteries
Backup time/full load
Recharge time
Dimensions
W x D x H mm
6 x 5-15R (US) 6 x 5-15R (US) 6 x 5-15R (US)
Lead-acid
7.2Ah/12V
Lead-acid
7.2Ah/12V
Lead-acid
9Ah/12V
4 x 5-15R (US)
Lead-acid
7.2Ah/12V
4 x 5-15R (US)
Lead-acid
9Ah/12V
2 3 3 6 6
5 min
<4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90% <4 hours to 90%
428 x 425 x 84
6 min 5 min
428 x 425 x 84 428 x 425 x 84
6 min
428 x 610 x 84
5 min
428 x 610 x 84
19” Rack-mount Model (1U)
OUTPUT POWER
Connection Input
Connection Output
Battery type
Number of batteries
Backup time/ full load
Recharge time
Dimensions W x D x H mm
Weight kg
700VA/ 490 W 1000VA/ 700W
Attached power cord
4 x IEC 320 (10A)
3 x 5-15R (US)
4 x IEC 320 (10A)
3 x 5-15R (US)
Lead-acid 7 Ah/ 6V
4
6 min
<4 hours to 90%
428 x 525 x 44
15.5
Lead-acid 7 Ah/ 6V
4
4 min
<4 hours to 90%
428 x 525 x 44
15.5
Battery Cabinets
Battery type
700 VA
Lead-acid
7 Ah/12 V
1000 VA
Lead-acid
7 Ah/12 V
1500 VA
Lead-acid
7 Ah/12 V
2000 VA
Lead-acid
7 Ah/12 V
3000 VA
Lead-acid
7 Ah/12 V
Number of batteries
6 6 6 12 12
Backup time/ full load
Recharge time
Approx. 45 min Approx. 33 min Approx. 15 min Approx. 33 min Approx. 15 min
<12 h to 90% <9 h to 90% <8 h to 90% <8 h to 90% <8 h to 90%
Dimensions
W x D x H mm
Tower
152 x 420 x
238
152 x 420 x
238
152 x 420 x
238
225 x 425 x
360
225 x 425 x
360
RM2U 428 x 425 x 84 428 x 425 x 84 428 x 425 x 84 428 x 610 x 84 428 x 610 x 84
Weight Kg
32
Terminal Block (optional)
Please refer to the terminal block connection diagram to connect and use No. 10 AWG, 90°C
copper wire and 20 lb-in torque force when connecting.
CAUTION :
To reduce the risk of fire, connect only to a circuit provided with 30 amperes maximum branch circuit overcurrent protection in accordance with the National
Electrical Code, ANSI/NFPA 70.
33
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Consistent and clean power during outages
- Protection from surges, brownouts, and voltage irregularities
- Automatic voltage regulation (AVR) to correct voltage fluctuations
Related manuals
Frequently Answers and Questions
What type of power does the Eaton 700VA provide?
What is the purpose of the Eaton 700VA?
What are the benefits of using the Eaton 700VA?
advertisement
Table of contents
- - Introduction
- - System description
- - 2.1 General description
- - 2.2 System Configuration
- - Safety Information
- - Storage
- - Installation
- - 5.1 Environment
- 3 5.2 Rear panel views
- 8 5.3 Connection to mains and loads (700 - 3000 VA)
- 9 5.4 Default settings at the factory
- 10 Computer and Alarm connections
- 11 6.1 EPO port (emergency power off)
- 11 6.2 Load segments (700 - 3000 VA)
- 12 User’s guide to operations
- 12 7.1 Starting and shutting down the UPS
- 12 7.2 Button Operation
- 13 7.3 Control Panel functions
- 18 7.4 Interpreting UPS messages
- 19 7.5 Trouble shooting
- 16 Maintenance
- 16 8.1 Replacing batteries
- 17 Warranty
- 17 Technical Specifications
- 17 10.1 Power Range 700-3000 VA (LV)
- 17 10.2 Power Range 700-3000 VA (HV)
- 17 10.3 Power Range 700-3000 VA (19” Rack-mount model)