User's Manual Rev A / November 2015 / M600/M400 Helium Compressor
6.3.5.1.
Compressor Front Panel Fault Errors
For the Model 600/ Model 400 compressors that have digital electrical box configurations as shown in Figure 3 and Figure 4 the following errors can be displayed:
•
System Error
•
Compressor Overload
•
Low Pressure
•
High Temperature
•
AC Power Phase Error
•
F13-F15 Fuse Blown
•
F16-F18 Fuse Blown
•
3PH Detected in 1PH Mode
•
1PH Detected in 3PH Mode
6.3.6.
Compressor System Shut Down
Manual shut-down
Push the OFF button or the Main Power Switch
Automatic shut-down
The following system indication will cause the compressor to automatically shut down:
1.
Low Helium pressure (not standard)
2.
High Helium pressure (not standard)
3.
High Helium temperature
4.
High Oil Return temperature
5.
Contactor Overload
6.
Loss of Power
If an automatic shut down occurs, refer to Table 6-5 to identify and remove the fault. Once the fault has been corrected, the user can restart the system by pressing the “ON” button.
6.3.7.
Compressor Interfaces
For the Model 600 / Model 400 compressors that have digital electrical box configurations shown in Figure 1 and Figure 2 a connector is provided for serial communication.
6.3.7.1.
Serial Port Interface (J2-RS232)
For the Model 600/ Model 400 compressors that have digital electrical box configurations as shown in Figure 1 and Figure
2 , a DB9 Male connector is provided for serial port communications. A “straight through” serial cable, as shown in Table
6-6 and Table 6-7 , is necessary for interfacing to the serial port. Only pins 2, 3, and 5 are required.
Table 6-6 – Serial Port Interface Pin Assignments
DB9 Female (to Compressor) DB9 (to Controller)
1
2(TxD)
3(RxD)
4
5(Gnd)
6
7
-------------
-------------
-------------
-------------
-------------
-------------
-------------
1
2(TxD)
3(RxD)
4
5(Gnd)
6
7
97-00046-000 23
advertisement
Related manuals
advertisement
Table of contents
- 7 PREFACE
- 9 SAFETY WARNINGS
- 9 High Voltage and Electrical Shock Warnings
- 9 High Pressure Related Warnings
- 9 Helium Gas-Related Warnings
- 10 Heat-Related Warnings
- 10 INTRODUCTION
- 10 Model 600 / Model 400 Features
- 10 Overview of Model 600 / Model 400 Compressor Design and Operation
- 11 Description of Subsystems
- 12 Operational Flow
- 18 INSTALLATION
- 18 Unpacking and Inspection
- 19 Mounting the Compressor
- 19 Preparing the Compressor for Operation
- 19 Installation
- 19 Ambient Conditions and Coolant Connection
- 20 Verifying and/or Refilling Compressor with Helium Gas
- 21 Connecting the Helium Flex Lines
- 21 Electrical Connection
- 24 OPERATION
- 24 Cycle Times
- 24 Remote Interface
- 26 D-Sub User Controls
- 27 D-Sub User Status
- 27 Compressor Front Panel User Interface
- 28 Compressor Front Panel User Interface Revised
- 28 Compressor Operational Checks
- 29 Compressor Front Panel Fault Errors
- 29 Compressor System Shut Down
- 29 Compressor Interfaces
- 29 Serial Port Interface (J2-RS232)
- 30 USB Interface (J1-Maintenance)
- 30 Serial Communications via RS
- 30 Serial Port Commands
- 32 Communications via USB
- 33 USB Payload Formats
- 37 TROUBLESHOOTING
- 39 MAINTENANCE
- 40 Remove the Compressor Adsorber
- 44 Install Replacement Adsorber
- 44 Removing Helium Contamination