Software Developer Guide, 5326-903, Rev A.0
The plain command APDU for HF media (iCLASS), supported by the SIO Processor is:
FF 70 07 6B 15 A0 13 A1 11 80 01 04 84 0C 2B 06 01 04 01 81 E4 38 01 01 02 04 00
FF 70 07 6B 30 { Enc(plain APDU + PADDING, S-ENC) + C-MAC } 00
The command to send is encrypted according to clause 4.2.2.3.
Response:
9D
xx
// Tag = Response (1D)
// length of PAC Bits
PAC BIT STRING 1) // UNIVERSAL BIT_STRING TAG (1st byte) = 03
// Length of UNIVERSAL BIT_STRING (2nd byte) = nn
// Unused Bits (3rd byte) is the number of trailing 0s in the last byte
// PAC bits (ex 4th byte, nn-1 bytes) including required trailing zeros
Example response for 35bit PAC bit string 1):
9D
08
03 06 05 81 ED BE 15 60
1) Note: In use case of a secure channel is the PAC BIT STRING a server cryptogram (see
4.3 Update Reader Key
Update the reader key with the Load Keys (see chapter Error! Reference source not
found.) command. Establish a secure channel and transmit the following command:
Example: Updating the reader key
FF 82 // Load Keys
20 80
10
11 22 33 44 55 66 77 88 99 00 AA BB CC DD EE FF
Response:
90 00
// Reader key slot number 80
// Le
// New reader key
// SW1 SW2