Lotus Service Notes Section PN
PN.1 - GENERAL DESCRIPTION
The heating, ventilation and air conditioning (HVAC) main unit comprises a plastic casing secured to the front face of the main chassis tub, housing the fan blower, a.c. evaporator and heater matrix, with a fresh air inlet adaptor on its top face, a re-circulation intake port on the rear face, and an outlet to the air distribution chamber on the top rear of the unit.
Heater Circuit
The heating system uses engine coolant to provide a heat source transferred to the interior airstream via a heat exchanger matrix mounted within the HVAC unit. Hot coolant is directed from an offtake on the engine outlet housing at the rear of the cylinder head, via a re-circulation pump (see below), into pipework running through the LH sill, and connecting to the heater matrix. The outlet from the matrix connects to return pipwork routed alongside the supply line to the LH end of the heater return rail. This rail runs down the 'V' of the cylinder block, alongside the by-pass pipe, and connects to the engine side of the thermostat housing at the front of the engine.
In conditions of 'heat soak', after stopping a hot engine, the electric re-circulation pump mounted in the heater supply line at the LH side of the engine bay, is energised under engine ECU control, to pump coolant around the heater circuit and limit the potential for localised boiling within the cylinder head.
Air Conditioning - Basic Principles
The air conditioning unit uses a variable displacement compressor system with a thermostatic expansion valve to provide refrigerated air to the vehicle interior. The system comprises:
- a closed circuit containing refrigerant R134a;
- a variable displacement compressor mounted on the front side of the engine, driven by multi-vee belt from the front end of the crankshaft via an electromagnetic clutch;
- a condenser fixed to the front of the engine cooling radiator, between the front subframe longerons and tilted forwards at 45°;
- an evaporator unit (cooler) contained within the HVAC housing ahead of the cabin footwell bulkhead;
- a thermostatic expansion valve fitted at the inlet connection to the evaporator;
- a refrigerant receiver-drier unit mounted on the outside of the front subframe RH longeron, ahead of the
RH front wheel.
Closed Circuit
The closed refrigerant circuit should not be opened unless absolutely necessary, and only then using appropriate refrigerant recovery equipment. Never allow the refrigerant to vent to atmosphere. Refer to subsection PN.5. Failure to observe these precautions may result in personal injury.
The discharge hose from the engine driven compressor connects to a rigid aluminium pipe at the RH side of the engine bay, with the junction supported on an vibration isolator plate. The high pressure discharge pipe is routed through the RH body sill via foam support blocks clamped to the outside of the chassis main siderail. At the rear of the RHF wheelarch, the pipe rises to another junction plate secured to the outside of the subframe longeron, where it connects to the condenser supply pipe/hose assembly which runs over the wheelarch area to the RH side of the condenser, to which it connects on the topside. The condenser outlet union is sited alongside the inlet union, and supplies a rigid aluminium pipe running to the receiver-drier unit mounted ahead of the RHF wheelarch. From here, another pipe, incorporating the trinary switch, connects to the expansion valve mounted on the evaporator inlet pipe at the RH side of the HVAC unit. Refrigerant leaving the evaporator passes through the expansion valve into a pipe/hose assembly which connects to a sill pipe and then continues to run in parallel to the supply line back to the compressor.
Page 3
Lotus Service Notes Section PN
Compressor
The variable displacement compressor is mounted on the front side of the engine, and is driven by the multi-rib auxiliary belt. The compressor operates to discharge refrigerant vapour at high pressure and temperature into the condenser and is lubricated by a quantity of special refrigerant oil, most of which is retained in the compressor, with the remainder being circulated with the refrigerant. The compressor contains a ring of cylinders with axes parallel to the compressor drive shaft, and whose pistons are driven up and down the bores by a rotating 'swash plate', the angle of which, in relation to the drive shaft, is variable. With a small swash plate angle, a short piston stroke is produced for a low refrigerant flow; a high swash plate angle results in greater piston stroke for a higher flow of refrigerant. The angle of the swashplate is determined by the pressure differential between that on top of the pistons, and that within the housing, applying a force to the underside of the pistons, in conjunction with a coil spring around the drive shaft.
This differential is controlled by a solenoid valve under ECU control, using pulse width modulation. When the valve is open, the output from the cylinders is bled off to the compressor housing to result in no pressure differential. The angle of the swashplate is then determined by the coil spring which pushes the plate to a near neutral position to provide minimal flow. As the valve is progressively closed, the pressure differential increases, with the pressure on top of the pistons pushing the swashplate to a greater angle, and producing an increased refrigerant flow.
The engine ECU is programmed to minimise refrigerant flow until an a.c. request is made, thus allowing the compressor to be run at all times in the interests of system lubrication, and the reduction of inactivity damage.
To safeguard the drive system in the event of compressor seizure, an electromagnetic clutch in the pulley hub is used to disengage the drive as signalled by a sensor in the compressor nose. The clutch will also be disengaged by the ECU if a loss of refrigerant is detected by the trinary switch (see below).
Hot refrigerant vapour from the compressor is fed via flexible hoses and alloy pipwork routed through the body RH sill, to the front mounted condenser.
Condenser
The aluminium condenser is a 'parallel flow' heat exchanger, configured with side mounted collector tanks interconnected by 40 oval shaped, horizontal tubes, all provided with generous finning. The unit is fixed to the front of the engine cooling radiator, sited between the longerons of the front subframe, and angled forwards at
45°. The hot vapour received from the compressor, is admitted into the top section of the RH condenser tank, and flows through 32 tubes to the LH tank before returning to the lower section of the RH tank via the bottom
8 tubes. In so doing, heat is released to the surrounding air via the condenser finning, with airflow boosted by two electric fans mounted on top of the engine radiator, and ram air flow caused by vehicle movement.
A union at the bottom of the RH tank directs the condensed, liquid refrigerant into pipework connecting with the receiver-drier.
Receiver-Drier
The receiver-drier unit is fitted into the refrigerant line between the condenser and evaporator expansion valve, and houses a screen sack filled with desiccant to absorb traces of moisture and other contaminants from the refrigerant. The unit is mounted on the outside of the subframe RH longeron, ahead of the RHF wheel.
A trinary switch fitted into the pipe between the receiver-drier and expansion valve supplies a pressure signal to the engine ECU, which then allows system operation only within a pressure range of 2 to 32 bar in order to prevent system damage from too high a pressure, or from compressor oil starvation damage caused by too low a pressure. This data is also used by the ECU to engage the two condenser fans at half speed at pressures over 17.5 bar (see also sub-section KJ.5).
Expansion Valve
The expansion valve block is fitted into the high and low pressure pipes at the evaporator connection, and provides a variable restriction to the flow of high pressure liquid into the evaporator, such that the consequent pressure drop causes a change of state to a low pressure, low temperature atomised liquid.
By sensing the temperature and pressure of refrigerant leaving the evaporator, the expansion acts to modulate the flow of refrigerant into the unit to optimise the cooling performance.
Page 4