Mounting. Micro Motion Liquified Natural Gas Meter

Add to my manuals
32 Pages

advertisement

Mounting. Micro Motion Liquified Natural Gas Meter | Manualzz

Installation Manual

MMI-20032351

3

3.1

3.2

Mounting

August 2019

Mounting

Provide for maintenance accessibility

Mount the electronics enclosure in a location and orientation that satisfies the following conditions:

• Allows sufficient clearance to open the enclosure cover. Micro Motion recommends

7.88 in (200 mm) to 9.85 in (250 mm) clearance at the rear of the electronics enclosure.

• Provides clear access for installing cabling to the enclosure.

Mount the LNG sensors

Use best practices to minimize torque and bending load on process connections.

CAUTION

Do not lift the sensor by the electronics or cable as this can damage the device.

Procedure

1. Mount the gas return sensor (the LNGS06).

• Do not use the sensor to support the piping.

• The sensor does not require external supports. The flanges will support the sensor in any orientation.

2. Mount the filling sensor (the LNGM10).

Installation Manual 9

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What should be considered if I plan to mount the LNG meter in a hazardous area?
Ensure that the hazardous area specified on the approval tag is suitable for the environment.
What are the temperature limits for the LNG meters?
Verify that the local ambient and process temperatures are within the limits specified for the LNG meters.
What type of power is required for the core processor?
Low-voltage DC power is required for the core processor. Excess voltage can damage the core processor.
How should the LNG electronics be mounted?
Mount the LNG electronics in any orientation as long as the conduit openings do not point upward to avoid condensation entering the housing and damaging the electronics.
How should the sensors be installed?
Install the sensors so that the flow direction arrow on the case matches the actual forward flow of the process.