Expanded Cooling Data. GOODMAN GSX13
PDF
سند
تبلیغات
تبلیغات
GSX13 Energy-Efficient Split System Air Conditioner 13 SEER / 1½ to 5 Tons Cooling Capacity: 18,000 - 60,000 BTU/h Contents Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data.......................... 4 Wiring Diagrams .................................. 20 Dimensions........................................... 22 Accessories........................................... 22 Standard Features Cabinet Features • • • • • Heavy-gauge galvanized-steel cabinet with louvered sound control top • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • Steel louver coil guard • Single-panel access to controls with space provided for field-installed accessories Energy-efficient compressor Factory-installed filter drier Copper tube/aluminum fin coil Service valves with sweat connections and easy-access gauge ports • Contactor with lug connection • Ground lug connection • AHRI Certified; ETL Listed * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 2-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GSX13 www.goodmanmfg.com 7/20 Supersedes 6/20 . Nomenclature G S X 13 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand G Engineering Major & Minor Revisions Goodman® Brand (not used for inventory or ordering) Product Category S Electrical Split System 1 208/230 V, 1 Phase, 60 Hz 2 220/240 V, 1 Phase, 50 Hz Unit Type 3 208/230 V, 3 Phase, 60 Hz X Condenser R-410A Z Heat Pump R-410A Efficiency 2 Nominal Capacity 018 1½ Tons 030 2½ Tons 042 3½ Tons 019 1½ Tons 031 2½ Tons 043 3½ Tons 13 13 SEER 16 16 SEER 024 2 Tons 036 3 Tons 048 4 Tons 14 14 SEER 18 18 SEER 025 2 Tons 037 3 Tons 060 5 Tons www.goodmanmfg.com SS-GSX13 Product Specifications GSX13 0181E* GSX13 0181EH GSX13 0181EJ GSX13 0241E* GSX13 0301B* GSX13 0301L* GSX13 0361E* GSX13 0421B* GSX13 0481B* GSX13 0601B* GSX13 0611A* Nominal Cooling (BTU/h) 18,000 18,000 18,000 23,000 SEER / EER 13/11 13/11 13/11 13/11 30,000 30,000 36,000 42,000 48,000 60,000 60,000 13/11 13 / 11 13/11 13/11 13/11 13/11 13/11 Decibels 75 75 75 75 73 74 74 75 76 77 72 RLA 6.7 6.7 6.0 7.7 12.8 10.5 13.6 17.9 19.9 25.0 26.4 LRA 41 37.5 37.5 37 64 47 79 112 109 134 134 Horsepower 1/8 1/8 1/8 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 FLA 0.7 0.65 0.65 0.65 0.65 0.7 1.4 1.4 1.4 1.4 1.3 Liquid Line Size (“O.D.) ⅜" ⅜” ⅜” ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Line Size (“O.D.) ¾" ¾” ¾” ¾" ¾" ¾" ⅞" 1⅛" 1⅛" 1⅛" ⅞" Liquid Valve Size (“O.D.) ⅜" ⅜” ⅜” ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Valve Size (“O.D.) ⁴ ⁵ ¾" ¾” ¾” ¾" ¾" ¾" ¾" ⁴ ⅞" ⁵ ⅞" ⁵ ⅞" ⁵ ¾" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 44 58 58 60 60 68 62 80 91 94 111 Shipped with Orifice Size 0.051 0.051 0.051 0.055 0.061 0.067 0.070 0.076 0.080 0.086 0.086 208/230 208/230-60 208/230 208/230 208/230 208/230 208/230 Capacities Compressor Condenser Fan Motor Refrigeration System Refrigerant Line Size ¹ Refrigerant Connection Size Electrical Data Voltage (60 Hz) Minimum Circuit Ampacity ² 208/230 208/230-60 208/230-60 208/230 9.1 8.2 10.3 16.7 13.8 19.0 23.8 26.3 32.7 34.3 Max. Overcurrent Protection ³ 15 amps 9.1 15 amps 15 amps 15 amps 25 amps 20 30 amps 40 amps 45 amps 50 amps 60 amps Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size ½" or ¾" ½” or ¾” ½” or ¾” ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" Equipment Weight (lbs) 102 102 102 103 115 138 118 171 175 184 211 Ship Weight (lbs) 117 117 117 120 132 153 135 189 193 202 233 ¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to the installation & Operating instructions and/or the long line-set guidelines. ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. ⁴ Installer will need to supply ¾” to ⅞” adapters for suction line connections. ⁵ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. Notes • Always check the S&R plate for electrical data on the unit being installed. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • This product may not be installed in the Southeast (including Hawaii) or Southwest Regions as of Jan. 1, 2015. SS-GSX13 www.goodmanmfg.com 3 4 www.goodmanmfg.com 650 600 525 650 600 525 15.9 0.80 22.3 1.03 4.3 205 104 16.7 0.81 20.8 1.04 4.4 208 105 17.2 0.83 20.2 1.06 4.4 211 107 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 59 15.6 0.70 19.3 1.02 4.3 203 102 16.4 0.71 18.0 1.03 4.3 206 104 16.9 0.73 17.5 1.05 4.4 209 106 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR Airflow 63 16.4 0.72 20.5 1.05 4.4 221 110 17.2 0.73 19.1 1.07 4.5 224 112 17.7 0.74 18.6 1.08 4.5 228 114 16.2 0.59 16.7 1.04 4.4 219 109 17.0 0.60 15.6 1.06 4.4 221 110 17.6 0.61 15.1 1.07 4.5 225 112 67 17.7 0.54 16.8 1.09 4.6 233 120 18.6 0.55 15.7 1.10 4.6 236 122 19.2 0.56 15.2 1.12 4.7 240 124 17.7 0.41 12.7 1.08 4.5 231 119 18.7 0.41 11.8 1.09 4.6 234 121 19.2 0.42 11.5 1.11 4.6 238 123 19.0 0.35 11.6 1.13 4.7 243 128 20.0 0.35 10.8 1.14 4.8 246 130 20.6 0.36 10.5 1.16 4.9 251 132 - 71 15.5 0.83 22.5 1.12 4.7 230 109 16.3 0.84 21.0 1.13 4.7 233 111 16.8 0.86 20.4 1.15 4.8 237 113 59 15.3 0.73 19.5 1.11 4.6 228 108 16.0 0.74 18.2 1.12 4.7 231 110 16.5 0.76 17.7 1.14 4.7 235 112 63 16.0 0.74 20.7 1.14 4.8 248 116 16.8 0.75 19.4 1.16 4.8 251 118 17.3 0.77 18.8 1.17 4.9 255 120 15.8 0.61 16.9 1.13 4.7 245 115 16.6 0.62 15.8 1.14 4.8 248 117 17.1 0.63 15.3 1.16 4.9 253 119 67 17.3 0.56 17.0 1.18 4.9 262 127 18.2 0.57 15.9 1.20 5.0 265 129 18.7 0.58 15.4 1.21 5.1 270 131 17.3 0.42 12.8 1.17 4.9 259 126 18.2 0.43 12.0 1.18 4.9 262 127 18.8 0.44 11.6 1.20 5.0 267 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 18.6 0.36 11.7 1.22 5.1 273 135 19.5 0.37 11.0 1.24 5.2 276 137 20.1 0.37 10.7 1.26 5.3 281 139 - 71 63 15.6 0.76 20.8 1.22 5.2 282 121 16.4 0.77 19.4 1.23 5.2 285 123 16.9 0.79 18.8 1.25 5.3 290 125 15.4 0.62 16.9 1.21 5.1 279 120 16.2 0.63 15.8 1.22 5.2 283 121 16.7 0.65 15.3 1.24 5.3 287 123 67 16.9 0.58 17.0 1.26 5.4 297 132 17.8 0.58 15.9 1.28 5.4 301 134 18.3 0.60 15.4 1.30 5.5 307 136 16.9 0.43 12.8 1.25 5.3 294 131 17.8 0.44 12.0 1.27 5.4 298 132 18.3 0.45 11.6 1.29 5.5 304 135 18.1 0.37 11.7 1.31 5.6 310 141 19.1 0.38 11.0 1.32 5.6 314 142 19.6 0.38 10.7 1.34 5.7 320 145 - 71 59 14.8 0.88 22.7 1.26 5.4 298 119 15.5 0.89 21.2 1.27 5.5 302 121 16.0 0.91 20.6 1.29 5.6 307 123 14.5 0.77 19.6 1.25 5.4 295 118 15.3 0.78 18.4 1.26 5.4 299 120 15.8 0.80 17.8 1.28 5.5 304 122 Shaded area reflects ACCA (TVA) conditions 15.2 0.85 22.6 1.19 5.1 262 114 15.9 0.86 21.1 1.21 5.1 265 115 16.4 0.88 20.5 1.22 5.2 270 117 59 14.9 0.75 19.5 1.18 5.0 259 113 15.7 0.76 18.2 1.19 5.1 263 114 16.1 0.78 17.7 1.21 5.2 267 116 16.5 0.59 17.1 1.33 5.7 339 139 17.3 0.60 16.0 1.35 5.8 343 141 17.9 0.62 15.5 1.37 5.9 349 143 15.2 0.78 20.9 1.29 5.5 321 127 16.0 0.80 19.5 1.30 5.6 325 129 16.5 0.81 19.0 1.32 5.7 331 131 67 16.5 0.45 12.9 1.32 5.7 335 137 17.4 0.45 12.1 1.34 5.7 340 139 17.9 0.46 11.7 1.36 5.8 346 142 63 15.1 0.64 17.0 1.28 5.5 318 126 15.8 0.65 15.9 1.29 5.6 322 127 16.3 0.67 15.4 1.31 5.6 327 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 17.7 0.38 11.8 1.38 5.9 353 148 18.6 0.39 11.1 1.40 6.0 358 150 19.2 0.40 10.7 1.42 6.1 364 152 - 71 14.0 0.91 22.4 1.32 5.8 335 125 14.8 0.92 20.9 1.33 5.8 340 127 15.2 0.94 20.3 1.35 5.9 346 129 59 13.8 0.80 19.4 1.30 5.7 332 124 14.5 0.81 18.1 1.32 5.8 336 126 15.0 0.83 17.6 1.34 5.9 342 128 14.5 0.81 20.6 1.35 5.9 361 133 15.2 0.83 19.3 1.36 6.0 366 135 15.7 0.84 18.7 1.38 6.1 372 137 63 14.3 0.67 16.8 1.33 5.8 357 132 15.0 0.68 15.7 1.35 5.9 362 134 15.5 0.69 15.2 1.37 6.0 368 136 15.7 0.62 16.9 1.39 6.1 381 145 16.5 0.63 15.8 1.41 6.2 386 147 17.0 0.64 15.3 1.43 6.3 393 150 67 15.7 0.46 12.7 1.38 6.0 377 144 16.5 0.47 11.9 1.40 6.1 382 146 17.0 0.48 11.6 1.42 6.2 389 148 105ºF 13.0 0.92 20.9 1.36 6.1 371 129 13.7 0.93 19.5 1.38 6.2 376 131 14.1 0.95 19.0 1.40 6.3 382 133 59 12.8 0.81 18.1 1.35 6.0 367 128 13.4 0.82 16.9 1.37 6.1 372 130 13.9 0.84 16.4 1.39 6.2 378 132 13.4 0.82 19.3 1.40 6.3 399 138 14.1 0.83 18.0 1.41 6.3 404 140 14.5 0.85 17.5 1.44 6.4 411 142 63 13.3 0.67 15.7 1.38 6.2 395 136 13.9 0.69 14.6 1.40 6.3 400 138 14.4 0.70 14.2 1.42 6.4 407 141 14.5 0.62 15.8 1.45 6.5 421 150 15.2 0.63 14.7 1.46 6.5 427 152 15.7 0.64 14.3 1.49 6.6 434 155 67 14.5 0.47 11.9 1.43 6.4 417 149 15.3 0.47 11.1 1.45 6.5 422 151 15.7 0.48 10.8 1.47 6.6 430 153 15.6 0.40 10.9 1.50 6.7 439 160 16.4 0.41 10.2 1.52 6.8 445 162 16.9 0.41 9.9 1.54 6.9 453 165 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 16.8 0.40 11.7 1.44 6.3 398 155 17.7 0.40 10.9 1.46 6.4 403 157 18.2 0.41 10.6 1.48 6.5 410 160 - 71 115ºF Expanded Cooling Data — GSX130181E* / CAPF1824B6DB SS-GSX13 SS-GSX13 www.goodmanmfg.com 650 600 525 650 600 525 16.5 0.92 26.5 1.05 4.4 209 106 17.3 0.93 24.8 1.06 4.4 212 107 17.8 0.95 24.1 1.08 4.5 216 109 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 59 16.2 0.88 24.8 1.04 4.3 207 105 17.0 0.89 23.2 1.05 4.4 210 106 17.5 0.91 22.5 1.07 4.5 214 108 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR Airflow 63 16.8 0.89 26.1 1.07 4.5 225 112 17.6 0.90 24.3 1.08 4.5 228 114 18.2 0.92 23.7 1.10 4.6 232 116 16.5 0.82 23.8 1.06 4.4 223 111 17.4 0.84 22.2 1.08 4.5 226 113 17.9 0.85 21.6 1.09 4.6 230 115 67 17.6 0.80 24.6 1.11 4.6 238 123 18.5 0.81 23.0 1.12 4.7 241 124 19.0 0.83 22.4 1.14 4.8 245 126 17.7 0.67 20.7 1.10 4.6 235 121 18.6 0.68 19.3 1.11 4.7 239 123 19.1 0.69 18.8 1.13 4.7 243 125 18.7 0.65 21.3 1.15 4.8 248 131 19.7 0.66 19.9 1.16 4.9 251 132 20.3 0.67 19.4 1.18 4.9 256 135 71 18.9 0.50 16.5 1.14 4.8 246 129 19.8 0.51 15.5 1.15 4.8 249 131 20.5 0.52 15.0 1.17 4.9 253 133 16.1 0.95 26.8 1.14 4.7 235 112 16.9 0.97 25.1 1.15 4.8 238 113 17.4 0.99 24.3 1.17 4.9 242 115 59 15.8 0.91 25.2 1.13 4.7 232 110 16.6 0.92 23.5 1.14 4.8 236 112 17.1 0.94 22.8 1.16 4.8 240 114 63 16.4 0.92 26.4 1.16 4.9 253 119 17.2 0.93 24.6 1.18 4.9 256 120 17.8 0.95 23.9 1.19 5.0 261 122 16.1 0.85 24.1 1.15 4.8 250 118 17.0 0.87 22.5 1.17 4.9 254 119 17.5 0.88 21.9 1.18 4.9 258 121 67 17.2 0.83 24.9 1.20 5.0 267 130 18.0 0.84 23.3 1.22 5.1 270 131 18.6 0.86 22.6 1.23 5.2 275 134 17.3 0.69 21.0 1.19 5.0 264 128 18.1 0.70 19.6 1.21 5.0 268 130 18.7 0.72 19.0 1.22 5.1 272 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 18.3 0.67 21.6 1.24 5.2 278 138 19.2 0.68 20.2 1.26 5.3 282 140 19.8 0.70 19.6 1.28 5.4 287 142 71 18.4 0.52 16.7 1.23 5.2 276 137 19.4 0.53 15.6 1.25 5.2 279 138 20.0 0.54 15.2 1.27 5.3 284 141 63 16.0 0.94 26.4 1.24 5.3 287 123 16.8 0.96 24.7 1.26 5.3 291 125 17.3 0.98 24.0 1.28 5.4 296 127 15.8 0.87 24.1 1.23 5.2 285 122 16.6 0.89 22.5 1.25 5.3 288 124 17.1 0.91 21.9 1.26 5.4 293 126 67 16.8 0.85 25.0 1.28 5.5 303 135 17.6 0.86 23.3 1.30 5.5 308 136 18.2 0.88 22.7 1.32 5.6 313 139 16.8 0.71 21.0 1.27 5.4 300 133 17.7 0.72 19.6 1.29 5.5 304 135 18.2 0.74 19.0 1.31 5.6 310 137 71 17.9 0.69 21.6 1.33 5.7 317 143 18.8 0.70 20.2 1.35 5.7 321 145 19.4 0.72 19.6 1.37 5.8 326 148 18.0 0.53 16.8 1.32 5.6 313 142 18.9 0.54 15.7 1.33 5.7 318 144 19.5 0.55 15.2 1.36 5.8 323 146 Shaded area reflects AHRI conditions 15.7 0.98 26.9 1.21 5.2 267 116 16.5 0.99 25.1 1.23 5.2 271 118 17.0 1.00 24.1 1.25 5.3 275 120 59 15.4 0.93 25.2 1.20 5.1 264 115 16.2 0.95 23.5 1.22 5.2 268 116 16.7 0.97 22.8 1.24 5.2 273 118 59 15.3 1.00 26.8 1.28 5.5 304 122 16.1 1.00 24.7 1.30 5.6 308 123 16.6 1.00 23.5 1.32 5.7 314 126 15.0 0.96 25.4 1.27 5.5 301 121 15.8 0.98 23.7 1.28 5.5 305 122 16.3 1.00 23.1 1.30 5.6 310 124 63 15.6 0.97 26.6 1.31 5.6 327 130 16.4 0.99 24.8 1.33 5.7 332 131 16.9 1.00 23.9 1.35 5.8 337 134 15.4 0.90 24.3 1.30 5.6 324 128 16.2 0.92 22.7 1.32 5.7 328 130 16.7 0.94 22.0 1.34 5.8 334 132 67 16.3 0.88 25.1 1.36 5.8 346 141 17.2 0.89 23.5 1.37 5.9 350 143 17.7 0.91 22.8 1.40 6.0 356 146 16.4 0.73 21.1 1.35 5.8 342 140 17.3 0.75 19.7 1.36 5.9 347 142 17.8 0.76 19.2 1.38 5.9 353 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 17.4 0.71 21.8 1.41 6.1 361 151 18.3 0.72 20.3 1.42 6.1 365 153 18.9 0.74 19.7 1.45 6.2 372 155 71 17.6 0.55 16.9 1.39 6.0 357 149 18.5 0.56 15.8 1.41 6.1 362 151 19.0 0.57 15.3 1.43 6.2 368 154 14.5 1.00 25.5 1.34 5.9 342 128 15.3 1.00 23.4 1.36 5.9 347 129 15.8 1.00 22.3 1.38 6.0 353 132 59 14.3 1.00 25.0 1.33 5.8 339 126 15.0 1.00 23.0 1.34 5.9 343 128 15.5 1.00 21.9 1.36 6.0 349 130 14.8 1.00 26.0 1.37 6.0 368 136 15.6 1.00 23.9 1.39 6.1 373 138 16.1 1.00 22.7 1.41 6.2 380 140 63 14.6 0.94 24.0 1.36 6.0 365 134 15.4 0.95 22.4 1.38 6.0 369 136 15.8 1.00 22.4 1.40 6.1 376 139 15.5 0.91 24.8 1.42 6.2 389 148 16.3 0.93 23.2 1.44 6.3 394 150 16.8 0.95 22.5 1.46 6.4 401 153 67 15.6 0.76 20.8 1.41 6.2 385 147 16.4 0.77 19.5 1.42 6.2 390 149 16.9 0.79 18.9 1.45 6.3 397 151 105ºF 13.5 1.00 23.6 1.39 6.2 378 132 14.2 1.00 21.7 1.41 6.3 383 134 14.6 1.00 20.6 1.43 6.4 390 136 59 13.2 1.01 23.4 1.38 6.2 374 131 13.9 1.00 21.3 1.39 6.2 379 132 14.3 1.00 20.3 1.42 6.3 386 135 13.7 1.00 24.1 1.42 6.4 407 140 14.4 1.00 22.1 1.44 6.4 412 142 14.9 1.00 21.0 1.46 6.6 419 145 63 13.5 0.94 22.4 1.41 6.3 403 139 14.2 0.96 20.9 1.43 6.4 408 141 14.7 1.00 20.7 1.45 6.5 415 143 14.4 0.92 23.2 1.47 6.6 430 153 15.1 0.93 21.6 1.49 6.7 435 155 15.6 0.95 21.0 1.51 6.8 443 158 67 14.5 0.77 19.5 1.46 6.5 425 152 15.2 0.78 18.2 1.48 6.6 431 154 15.7 0.80 17.7 1.50 6.7 439 157 15.3 0.75 20.0 1.53 6.8 448 163 16.1 0.76 18.7 1.54 6.9 454 166 16.6 0.77 18.2 1.57 7.0 462 168 71 15.5 0.57 15.5 1.51 6.8 444 162 16.2 0.58 14.5 1.53 6.9 450 164 16.7 0.60 14.1 1.55 7.0 457 167 Amps = outdoor unit amps (comp.+fan) kW = Total system power 16.6 0.74 21.5 1.47 6.4 406 158 17.4 0.75 20.0 1.49 6.5 411 160 18.0 0.77 19.5 1.51 6.6 418 163 71 16.7 0.57 16.6 1.46 6.4 402 156 17.5 0.58 15.5 1.48 6.5 407 158 18.1 0.59 15.1 1.50 6.6 414 161 115ºF Expanded Cooling Data — GSX130181E* / CAPF1824B6DB (cont.) 5 6 www.goodmanmfg.com 700 800 900 700 800 900 22.9 0.83 19 1.64 5.9 231 106 22.3 0.79 20 1.63 5.8 228 105 20.5 0.76 21 1.59 5.7 222 102 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 59 22.5 0.73 17 1.63 5.8 228 105 21.9 0.70 18 1.62 5.8 226 104 20.2 0.67 18 1.58 5.6 219 101 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR Airflow 63 23.6 0.74 18 1.67 6.0 248 113 22.9 0.71 19 1.66 6.0 246 112 21.1 0.68 19 1.62 5.8 238 108 23.4 0.61 15 1.66 6.0 246 112 22.7 0.58 15 1.65 5.9 243 111 20.9 0.56 15 1.61 5.7 236 107 67 25.5 0.56 15 1.72 6.2 262 123 24.8 0.54 15 1.71 6.2 260 122 22.9 0.52 16 1.67 6.0 252 118 25.6 0.42 11 1.71 6.2 259 122 24.8 0.40 12 1.70 6.1 257 121 22.9 0.39 12 1.66 5.9 249 117 27.4 0.36 10 1.77 6.4 273 131 26.6 0.34 11 1.76 6.4 271 130 24.6 0.33 11 1.72 6.2 263 126 - 71 22.4 0.86 20 1.76 6.3 259 112 21.7 0.82 20 1.75 6.3 256 111 20.1 0.79 21 1.71 6.1 249 108 59 22.0 0.76 17 1.75 6.3 256 111 21.4 0.72 18 1.73 6.2 254 110 19.7 0.70 18 1.69 6.1 246 106 63 23.0 0.77 18 1.79 6.5 279 119 22.4 0.73 19 1.78 6.4 276 118 20.7 0.71 19 1.74 6.3 267 114 22.8 0.63 15 1.78 6.4 276 118 22.2 0.60 15 1.77 6.4 273 117 20.4 0.58 16 1.73 6.2 265 113 67 24.9 0.58 15 1.85 6.7 294 130 24.2 0.56 15 1.84 6.7 291 129 22.4 0.54 16 1.79 6.5 282 125 25.0 0.44 11 1.83 6.7 291 129 24.3 0.42 12 1.82 6.6 288 127 22.4 0.40 12 1.78 6.4 280 124 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 26.8 0.37 10 1.91 7.0 307 139 26.0 0.36 11 1.89 6.9 304 137 24.0 0.34 11 1.85 6.7 295 133 - 71 24.4 0.60 15 1.96 7.3 334 135 23.6 0.57 15 1.95 7.2 331 134 21.8 0.55 16 1.90 7.0 321 130 22.5 0.79 18 1.90 7.1 317 124 21.8 0.75 19 1.89 7.0 314 123 20.2 0.73 19 1.84 6.8 304 119 67 24.4 0.45 11 1.95 7.2 331 134 23.7 0.43 12 1.93 7.2 328 132 21.9 0.41 12 1.89 7.0 318 129 63 22.3 0.65 15 1.89 7.0 314 123 21.6 0.62 15 1.87 6.9 310 121 20.0 0.60 16 1.83 6.7 301 118 26.1 0.38 10 2.02 7.6 349 144 25.4 0.37 11 2.01 7.5 345 143 23.4 0.35 11 1.96 7.3 335 138 - 71 59 21.3 0.91 20 1.96 7.4 335 122 20.7 0.87 21 1.94 7.3 332 121 19.1 0.84 21 1.90 7.1 322 117 21.0 0.80 17 1.94 7.3 332 121 20.4 0.76 18 1.93 7.2 329 120 18.8 0.74 18 1.88 7.0 319 116 Shaded area reflects ACCA (TVA) conditions 21.9 0.88 20 1.86 6.9 294 116 21.2 0.84 21 1.85 6.8 291 115 19.6 0.81 21 1.81 6.6 283 112 59 21.5 0.78 17 1.85 6.8 291 115 20.9 0.74 18 1.84 6.8 288 114 19.3 0.71 18 1.79 6.6 280 111 63 22.0 0.81 18 2.00 7.5 361 130 21.3 0.78 19 1.98 7.5 357 129 19.7 0.75 19 1.94 7.3 346 125 21.7 0.67 15 1.98 7.5 357 129 21.1 0.64 15 1.97 7.4 354 127 19.5 0.62 16 1.92 7.2 343 124 67 23.8 0.62 15 2.06 7.8 381 142 23.1 0.59 16 2.04 7.7 377 141 21.3 0.57 16 2.00 7.5 366 136 23.8 0.46 11 2.04 7.7 377 141 23.1 0.44 12 2.03 7.7 373 139 21.3 0.43 12 1.98 7.4 362 135 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 25.5 0.40 10 2.13 8.1 397 151 24.8 0.38 11 2.11 8.0 393 150 22.9 0.36 11 2.06 7.8 382 145 - 71 20.3 0.95 20 2.04 7.8 377 128 19.7 0.90 20 2.02 7.8 373 127 18.2 0.87 21 1.97 7.6 362 123 59 19.9 0.83 17 2.02 7.8 373 127 19.3 0.79 18 2.00 7.7 370 126 17.8 0.76 18 1.96 7.5 359 122 20.9 0.85 18 2.08 8.0 406 136 20.2 0.81 19 2.06 8.0 402 135 18.7 0.78 19 2.01 7.7 390 131 63 20.6 0.69 15 2.06 8.0 402 135 20.0 0.66 15 2.05 7.9 398 134 18.5 0.64 16 2.00 7.7 386 130 22.6 0.64 15 2.15 8.3 429 149 21.9 0.61 15 2.13 8.2 424 147 20.2 0.59 16 2.08 8.0 412 143 67 22.6 0.48 11 2.13 8.2 424 147 22.0 0.46 12 2.11 8.1 420 146 20.3 0.44 12 2.06 7.9 407 141 105ºF 18.8 0.95 18 2.10 8.3 417 133 18.2 0.91 19 2.09 8.2 413 131 16.8 0.88 19 2.04 8.0 400 127 59 18.4 0.84 16 2.09 8.2 413 131 17.9 0.80 16 2.07 8.2 408 130 16.5 0.77 17 2.02 7.9 396 126 19.3 0.85 17 2.15 8.5 448 141 18.8 0.81 18 2.13 8.4 444 140 17.3 0.78 18 2.08 8.2 431 135 63 19.1 0.70 14 2.13 8.4 444 140 18.6 0.67 14 2.11 8.4 440 138 17.1 0.64 14 2.06 8.1 426 134 20.9 0.65 14 2.22 8.8 474 154 20.3 0.62 14 2.20 8.7 469 152 18.7 0.59 15 2.15 8.5 455 148 67 21.0 0.49 10 2.20 8.7 469 152 20.3 0.46 11 2.18 8.6 464 151 18.8 0.45 11 2.13 8.4 450 146 22.4 0.42 10 2.29 9.1 494 164 21.8 0.40 10 2.27 9.1 489 162 20.1 0.38 10 2.22 8.8 474 157 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 24.2 0.41 10 2.21 8.6 447 158 23.5 0.39 11 2.20 8.5 443 157 21.7 0.38 11 2.14 8.3 429 152 - 71 115ºF Expanded Cooling Data — GSX130241E* / CA*F3030*6D* SS-GSX13 SS-GSX13 www.goodmanmfg.com 700 800 900 700 800 900 23.7 0.95 23 1.66 6.0 235 108 23.0 0.91 24 1.65 5.9 233 107 21.3 0.88 25 1.61 5.8 226 104 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 59 23.3 0.91 22 1.65 5.9 233 107 22.6 0.87 23 1.64 5.9 231 106 20.9 0.84 23 1.60 5.7 224 103 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR Airflow 63 24.2 0.92 23 1.70 6.1 253 115 23.5 0.88 24 1.69 6.1 251 114 21.7 0.85 24 1.65 5.9 243 110 23.8 0.85 21 1.69 6.1 251 114 23.1 0.81 22 1.67 6.0 248 113 21.4 0.79 22 1.63 5.9 241 109 67 25.3 0.83 22 1.75 6.3 267 126 24.6 0.79 22 1.74 6.3 265 124 22.7 0.76 23 1.70 6.1 257 121 25.5 0.69 18 1.74 6.3 265 124 24.7 0.66 19 1.72 6.2 262 123 22.8 0.64 19 1.68 6.0 254 119 27.0 0.67 19 1.80 6.6 279 134 26.2 0.64 19 1.79 6.5 276 132 24.2 0.62 20 1.75 6.3 268 128 71 27.2 0.52 14 1.79 6.5 276 132 26.4 0.50 15 1.78 6.4 273 131 24.4 0.48 15 1.73 6.3 265 127 23.2 0.99 23 1.79 6.5 264 114 22.5 0.94 24 1.77 6.4 261 113 20.8 0.91 25 1.73 6.2 254 110 59 22.8 0.94 22 1.77 6.4 261 113 22.1 0.90 23 1.76 6.3 259 112 20.4 0.87 23 1.72 6.2 251 109 63 23.6 0.95 23 1.82 6.6 284 122 22.9 0.91 24 1.81 6.6 281 120 21.2 0.88 24 1.77 6.4 273 117 23.3 0.88 21 1.81 6.6 281 120 22.6 0.84 22 1.79 6.5 279 119 20.9 0.81 22 1.75 6.3 270 116 67 24.8 0.86 22 1.88 6.8 300 133 24.0 0.82 23 1.86 6.8 297 131 22.2 0.79 23 1.82 6.6 288 127 24.9 0.72 18 1.86 6.8 297 131 24.2 0.69 19 1.85 6.7 294 130 22.3 0.66 19 1.81 6.5 285 126 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 26.4 0.70 19 1.94 7.1 313 141 25.6 0.67 20 1.92 7.0 310 140 23.7 0.64 20 1.88 6.8 301 136 71 26.6 0.54 15 1.92 7.0 310 140 25.8 0.51 15 1.91 7.0 307 139 23.8 0.50 15 1.86 6.8 298 134 63 23.1 0.98 23 1.93 7.2 323 126 22.4 0.93 24 1.92 7.1 320 125 20.7 0.90 24 1.87 6.9 310 121 22.7 0.91 21 1.92 7.1 320 125 22.1 0.87 22 1.90 7.1 317 124 20.4 0.83 22 1.86 6.9 307 120 67 24.2 0.88 22 1.99 7.4 341 138 23.5 0.84 23 1.98 7.4 338 137 21.7 0.81 23 1.93 7.2 328 132 24.3 0.74 18 1.98 7.4 338 137 23.6 0.70 19 1.96 7.3 335 135 21.8 0.68 19 1.92 7.1 324 131 71 25.8 0.72 19 2.06 7.7 356 147 25.0 0.68 20 2.04 7.6 352 145 23.1 0.66 20 1.99 7.4 342 141 26.0 0.55 15 2.04 7.6 352 145 25.2 0.53 15 2.02 7.6 349 144 23.3 0.51 16 1.98 7.4 338 140 Shaded area reflects AHRI conditions 22.6 1.00 23 1.89 7.0 300 119 22.0 0.97 24 1.88 7.0 297 118 20.3 0.93 25 1.83 6.8 288 114 59 22.2 0.97 22 1.88 7.0 297 118 21.6 0.92 23 1.86 6.9 294 116 19.9 0.89 23 1.82 6.7 286 113 59 22.1 1.00 23 1.99 7.5 342 125 21.4 1.00 25 1.97 7.4 339 123 19.8 0.96 25 1.93 7.2 328 120 21.7 1.00 22 1.97 7.4 339 123 21.1 0.95 23 1.96 7.4 335 122 19.4 0.92 23 1.91 7.2 325 119 63 22.5 1.00 23 2.03 7.7 368 133 21.9 0.96 24 2.01 7.6 364 131 20.2 0.93 25 1.97 7.4 353 127 22.2 0.94 21 2.01 7.6 364 131 21.5 0.89 22 2.00 7.5 361 130 19.9 0.86 22 1.95 7.3 350 126 67 23.6 0.91 22 2.09 7.9 389 145 22.9 0.87 23 2.08 7.9 385 143 21.1 0.84 23 2.03 7.7 373 139 23.7 0.76 18 2.08 7.9 385 143 23.0 0.73 19 2.06 7.8 381 142 21.2 0.70 20 2.01 7.6 370 138 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 25.1 0.74 19 2.16 8.2 405 154 24.4 0.71 20 2.14 8.2 401 153 22.5 0.68 20 2.09 7.9 389 148 71 25.3 0.57 15 2.14 8.2 401 153 24.6 0.54 15 2.13 8.1 397 151 22.7 0.52 16 2.08 7.9 385 147 21.0 1.00 21 2.07 8.0 385 131 20.4 1.00 23 2.05 7.9 381 129 18.8 1.00 25 2.00 7.7 370 126 59 20.6 1.00 21 2.05 7.9 381 129 20.0 0.99 23 2.04 7.8 377 128 18.5 0.95 23 1.99 7.6 366 124 21.4 1.00 22 2.11 8.2 414 139 20.8 1.00 24 2.10 8.1 410 138 19.2 0.96 24 2.05 7.9 398 134 63 21.1 1.00 22 2.10 8.1 410 138 20.5 0.93 22 2.08 8.0 406 136 18.9 0.89 22 2.03 7.8 394 132 22.4 0.95 22 2.18 8.5 437 152 21.7 0.90 23 2.16 8.4 433 150 20.1 0.87 23 2.11 8.1 420 146 67 22.5 0.79 18 2.16 8.4 433 150 21.9 0.75 19 2.15 8.3 429 149 20.2 0.73 19 2.09 8.1 416 144 105ºF 19.4 1.00 20 2.14 8.5 425 135 18.9 1.00 22 2.12 8.4 421 134 17.4 1.00 23 2.07 8.2 408 130 59 19.1 1.00 20 2.12 8.4 421 134 18.5 1.00 21 2.10 8.3 417 133 17.1 0.96 22 2.05 8.1 404 129 19.8 1.00 20 2.18 8.7 457 144 19.2 1.00 22 2.17 8.6 453 142 17.7 0.97 23 2.11 8.4 439 138 63 19.5 1.00 20 2.17 8.6 453 142 18.9 0.93 20 2.15 8.5 448 141 17.5 0.90 21 2.10 8.3 435 137 20.7 0.95 20 2.25 9.0 483 157 20.1 0.91 21 2.24 8.9 478 155 18.6 0.88 21 2.18 8.6 464 151 67 20.8 0.80 17 2.24 8.9 478 155 20.2 0.76 18 2.22 8.8 474 154 18.7 0.73 18 2.16 8.6 459 149 22.1 0.77 17 2.33 9.3 504 167 21.5 0.74 18 2.31 9.2 499 166 19.8 0.71 19 2.25 9.0 484 161 71 22.3 0.60 14 2.31 9.2 499 166 21.6 0.57 14 2.29 9.1 494 164 20.0 0.55 14 2.23 8.9 479 159 Amps = outdoor unit amps (comp.+fan) kW = Total system power 23.9 0.77 19 2.25 8.8 456 162 23.2 0.73 20 2.23 8.7 452 160 21.4 0.71 20 2.18 8.5 438 155 71 24.1 0.59 15 2.23 8.7 452 160 23.4 0.56 15 2.21 8.6 447 158 21.6 0.54 15 2.16 8.4 434 154 115ºF Expanded Cooling Data — GSX130241E* / CA*F3030*6D* (cont.) 7 8 www.goodmanmfg.com 25.4 0.82 22 1.62 6.7 211 104 27.5 0.85 20 1.66 6.9 217 107 27.8 0.86 20 1.67 6.9 218 107 MBh S/T ∆T 875 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 1125 kW Amps Hi PR Lo PR 59 24.9 0.72 19 1.60 6.6 209 103 27.0 0.74 18 1.65 6.8 215 106 27.3 0.76 17 1.65 6.9 216 106 MBh S/T ∆T 875 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 1125 kW Amps Hi PR Lo PR Airflow 63 26.1 0.73 20 1.66 6.9 227 110 28.3 0.76 19 1.70 7.1 234 114 28.6 0.77 18 1.71 7.1 234 114 25.8 0.60 16 1.64 6.8 224 109 28.0 0.62 15 1.69 7.0 231 113 28.3 0.63 15 1.69 7.0 232 113 67 28.3 0.55 16 1.72 7.1 239 121 30.6 0.57 15 1.76 7.3 247 124 30.9 0.58 15 1.77 7.4 248 125 28.3 0.42 12 1.70 7.0 237 119 30.7 0.43 12 1.75 7.3 244 123 31.0 0.44 11 1.75 7.3 245 123 30.3 0.36 11 1.78 7.4 250 128 32.9 0.37 11 1.83 7.6 257 132 33.2 0.38 10 1.83 7.7 258 133 - 71 24.8 0.85 22 1.76 7.3 236 110 26.8 0.88 21 1.81 7.5 244 113 27.1 0.89 20 1.81 7.5 245 113 59 24.4 0.74 19 1.74 7.2 234 109 26.4 0.77 18 1.79 7.4 241 112 26.7 0.79 17 1.80 7.5 242 112 63 25.5 0.76 20 1.80 7.5 254 117 27.6 0.78 19 1.85 7.7 262 120 27.9 0.80 18 1.86 7.7 263 121 25.2 0.62 16 1.78 7.4 252 116 27.4 0.64 15 1.83 7.6 260 119 27.6 0.66 15 1.84 7.7 260 119 67 27.6 0.57 17 1.87 7.7 269 127 29.9 0.59 16 1.92 8.0 277 131 30.2 0.61 15 1.92 8.0 278 132 27.7 0.43 13 1.85 7.7 266 126 30.0 0.45 12 1.90 7.9 274 130 30.3 0.45 11 1.91 7.9 275 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 29.6 0.37 11 1.93 8.1 280 136 32.1 0.38 11 1.99 8.3 289 140 32.4 0.39 10 1.99 8.3 290 140 - 71 63 24.9 0.78 20 1.93 8.2 289 121 27.0 0.80 19 1.98 8.4 298 125 27.2 0.82 18 1.99 8.5 299 125 24.6 0.64 16 1.91 8.1 286 120 26.7 0.66 15 1.97 8.3 295 124 27.0 0.67 15 1.97 8.4 296 124 67 26.9 0.59 17 2.00 8.5 306 132 29.2 0.61 16 2.06 8.7 315 136 29.5 0.62 15 2.06 8.8 316 137 27.0 0.44 13 1.98 8.4 303 131 29.3 0.46 12 2.04 8.6 312 135 29.5 0.47 11 2.04 8.7 313 136 28.9 0.38 11 2.07 8.8 319 141 31.3 0.39 11 2.13 9.1 329 145 31.6 0.40 10 2.14 9.1 330 146 - 71 59 23.6 0.89 22 1.99 8.6 306 120 25.6 0.93 21 2.05 8.8 316 123 25.8 0.95 20 2.06 8.9 317 124 23.2 0.79 19 1.97 8.5 303 119 25.1 0.82 18 2.03 8.7 313 122 25.4 0.83 17 2.04 8.8 314 123 Shaded area reflects ACCA (TVA) conditions 24.2 0.87 22 1.88 8.0 269 114 26.2 0.90 21 1.94 8.2 277 118 26.5 0.92 20 1.94 8.2 278 118 59 23.8 0.76 19 1.87 7.9 266 113 25.8 0.79 18 1.92 8.1 274 116 26.0 0.81 17 1.92 8.2 275 117 26.3 0.61 17 2.12 9.1 348 139 28.5 0.63 16 2.18 9.4 359 143 28.8 0.64 15 2.18 9.4 360 144 24.3 0.80 20 2.04 8.8 330 127 26.3 0.83 19 2.10 9.1 340 131 26.6 0.85 18 2.11 9.1 341 132 67 26.3 0.46 13 2.10 9.0 345 138 28.5 0.47 12 2.16 9.3 355 142 28.8 0.48 11 2.16 9.3 356 142 63 24.0 0.66 17 2.02 8.7 326 126 26.1 0.68 16 2.08 9.0 336 130 26.3 0.70 15 2.09 9.0 337 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 28.2 0.39 12 2.19 9.5 363 148 30.6 0.40 11 2.26 9.8 374 153 30.9 0.41 10 2.26 9.8 375 153 - 71 22.4 0.93 22 2.09 9.2 345 125 24.3 0.96 20 2.15 9.4 355 129 24.5 0.98 20 2.15 9.5 356 130 59 22.0 0.82 19 2.07 9.1 341 124 23.9 0.85 18 2.13 9.3 352 128 24.1 0.86 17 2.13 9.4 353 128 23.1 0.83 20 2.14 9.4 371 134 25.0 0.86 19 2.20 9.7 382 138 25.3 0.88 18 2.21 9.7 383 138 63 22.8 0.68 16 2.12 9.3 367 132 24.7 0.71 15 2.18 9.6 378 136 25.0 0.72 15 2.18 9.6 380 137 25.0 0.63 16 2.22 9.7 392 146 27.1 0.65 15 2.28 10.0 404 150 27.3 0.66 15 2.29 10.1 405 151 67 25.0 0.47 12 2.20 9.6 388 144 27.1 0.49 12 2.26 9.9 400 149 27.4 0.50 11 2.26 10.0 401 149 105ºF 20.8 0.94 20 2.17 9.7 381 130 22.5 0.97 19 2.23 10.0 393 134 22.7 0.99 18 2.24 10.1 394 134 59 20.4 0.82 18 2.15 9.6 377 128 22.1 0.85 17 2.21 9.9 389 132 22.3 0.87 16 2.21 10.0 390 133 21.4 0.84 19 2.22 10.0 410 138 23.2 0.87 18 2.28 10.3 422 142 23.4 0.89 17 2.29 10.3 424 143 63 21.2 0.69 15 2.20 9.9 406 137 22.9 0.71 14 2.26 10.2 418 141 23.2 0.73 14 2.27 10.2 419 141 23.1 0.63 15 2.30 10.4 433 151 25.1 0.66 14 2.37 10.7 446 155 25.3 0.67 14 2.37 10.7 447 156 67 23.2 0.48 12 2.28 10.2 428 149 25.1 0.49 11 2.35 10.6 442 154 25.4 0.50 10 2.35 10.6 443 154 24.8 0.41 11 2.39 10.8 451 161 26.9 0.42 10 2.46 11.1 465 166 27.2 0.43 10 2.46 11.1 467 166 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 26.8 0.40 11 2.30 10.1 408 155 29.0 0.42 11 2.36 10.4 421 160 29.3 0.43 10 2.37 10.5 422 161 - 71 115ºF Expanded Cooling Data — GSX130301L* / CA*F3030*6D*+EEP SS-GSX13 SS-GSX13 www.goodmanmfg.com 26.3 0.94 26 1.65 6.8 215 106 28.5 0.97 24 1.69 7.0 222 109 28.7 0.99 23 1.70 7.1 222 110 MBh S/T ∆T 875 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 1125 kW Amps Hi PR Lo PR 59 25.8 0.89 24 1.63 6.8 213 105 28.0 0.93 23 1.68 7.0 219 108 28.2 0.95 22 1.68 7.0 220 108 MBh S/T ∆T 875 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 1125 kW Amps Hi PR Lo PR Airflow 63 26.8 0.90 25 1.69 7.0 231 113 29.0 0.94 24 1.73 7.2 239 116 29.3 0.96 23 1.74 7.2 239 117 26.4 0.84 23 1.67 6.9 229 112 28.6 0.87 22 1.72 7.2 236 115 28.9 0.89 21 1.72 7.2 237 115 67 28.0 0.82 24 1.75 7.3 244 123 30.4 0.85 23 1.80 7.5 252 127 30.7 0.86 22 1.80 7.5 253 127 28.2 0.68 20 1.73 7.2 242 122 30.5 0.71 19 1.78 7.4 249 126 30.8 0.72 18 1.78 7.4 250 126 29.9 0.66 21 1.81 7.6 255 131 32.4 0.69 19 1.86 7.8 263 135 32.7 0.70 19 1.87 7.8 263 135 71 30.1 0.5 16 1.8 7.5 252.3 129.7 32.6 0.5 15 1.8 7.7 260.1 133.7 33.0 0.5 15 1.8 7.7 260.9 134.1 25.7 0.97 26 1.79 7.4 241 112 27.8 1.00 24 1.84 7.7 249 115 28.1 1.00 23 1.85 7.7 249 116 59 25.2 0.93 25 1.77 7.4 239 111 27.3 0.96 23 1.82 7.6 246 114 27.6 0.98 22 1.83 7.6 247 115 63 26.1 0.94 26 1.83 7.6 260 119 28.3 0.97 24 1.89 7.9 268 123 28.6 0.99 23 1.89 7.9 268 123 25.8 0.87 24 1.82 7.6 257 118 27.9 0.90 22 1.87 7.8 265 122 28.2 0.92 21 1.87 7.8 266 122 67 27.4 0.85 24 1.90 7.9 274 130 29.7 0.88 23 1.95 8.1 283 134 30.0 0.90 22 1.96 8.2 283 134 27.5 0.71 20 1.88 7.8 271 129 29.8 0.73 19 1.94 8.1 280 133 30.1 0.75 18 1.94 8.1 281 133 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 29.2 0.69 21 1.97 8.2 286 138 31.7 0.71 20 2.03 8.5 295 143 32.0 0.73 19 2.03 8.5 296 143 71 29.4 0.53 16 1.95 8.1 283 137 31.9 0.55 15 2.01 8.4 292 141 32.2 0.56 15 2.01 8.4 293 142 63 25.5 0.96 26 1.96 8.3 295 124 27.7 1.00 24 2.02 8.6 304 128 27.9 1.00 23 2.03 8.6 305 128 25.1 0.89 24 1.95 8.3 292 123 27.2 0.92 22 2.00 8.5 301 126 27.5 0.94 21 2.01 8.5 302 127 67 26.7 0.87 24 2.04 8.6 312 135 29.0 0.90 23 2.09 8.9 321 139 29.3 0.92 22 2.10 8.9 322 140 26.9 0.73 20 2.02 8.6 309 134 29.1 0.75 19 2.07 8.8 318 138 29.4 0.77 18 2.08 8.8 319 138 71 28.5 0.70 21 2.11 9.0 325 144 30.9 0.73 20 2.17 9.3 335 148 31.2 0.74 19 2.18 9.3 336 149 28.7 0.5 16 2.1 8.9 322.0 142.4 31.1 0.6 15 2.2 9.2 331.9 146.8 31.4 0.6 15 2.2 9.2 332.9 147.3 Shaded area reflects AHRI conditions 25.0 1.00 26 1.92 8.1 274 116 27.1 1.00 24 1.97 8.4 283 120 27.4 1.00 22 1.98 8.4 284 120 59 24.6 0.95 25 1.90 8.1 272 115 26.7 0.99 23 1.95 8.3 280 119 26.9 1.00 22 1.96 8.3 281 119 59 24.4 1.00 26 2.03 8.7 312 122 26.5 1.00 23 2.09 9.0 322 126 26.7 1.00 22 2.09 9.0 323 126 24.0 0.98 25 2.01 8.7 309 121 26.0 1.00 23 2.07 8.9 319 125 26.3 1.00 21 2.07 8.9 320 125 63 24.9 0.99 26 2.08 9.0 336 130 27.0 1.00 24 2.14 9.2 347 134 27.3 1.00 22 2.15 9.3 348 134 24.5 0.92 24 2.06 8.9 333 129 26.6 0.95 22 2.12 9.1 343 133 26.8 0.97 21 2.13 9.2 344 133 67 26.1 0.90 25 2.16 9.3 355 142 28.3 0.93 23 2.22 9.6 366 146 28.5 0.95 22 2.22 9.6 367 147 26.2 0.75 21 2.14 9.2 352 140 28.4 0.78 19 2.20 9.5 362 145 28.7 0.79 19 2.20 9.5 364 145 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 27.8 0.73 21 2.24 9.7 370 151 30.1 0.75 20 2.30 10.0 382 156 30.4 0.77 19 2.31 10.0 383 156 71 28.0 0.56 16 2.21 9.6 367 150 30.4 0.58 15 2.28 9.9 378 154 30.7 0.59 15 2.28 9.9 379 155 23.2 1.00 24 2.13 9.3 352 128 25.1 1.00 22 2.19 9.6 362 132 25.4 1.00 21 2.19 9.7 364 132 59 22.8 1.02 24 2.11 9.2 348 127 24.7 1.00 22 2.17 9.5 359 131 25.0 1.00 20 2.17 9.6 360 131 23.7 1.00 25 2.18 9.6 378 136 25.6 1.00 22 2.24 9.9 390 140 25.9 1.00 21 2.25 9.9 391 141 63 23.3 0.96 23 2.16 9.5 375 135 25.3 0.99 22 2.22 9.8 386 139 25.5 1.00 21 2.23 9.8 387 139 24.8 0.93 24 2.26 9.9 399 149 26.8 0.96 23 2.32 10.2 412 153 27.1 0.98 22 2.33 10.3 413 154 67 24.9 0.78 20 2.24 9.8 396 147 27.0 0.81 19 2.30 10.1 408 152 27.2 0.82 18 2.31 10.2 409 152 105ºF 21.5 1.00 23 2.21 9.9 388 132 23.3 1.00 20 2.27 10.2 400 137 23.5 1.00 19 2.28 10.3 402 137 59 21.1 1.03 23 2.19 9.8 385 131 22.9 1.00 20 2.25 10.1 396 135 23.1 1.00 19 2.26 10.2 398 136 21.9 1.00 23 2.26 10.2 418 141 23.7 1.00 21 2.33 10.5 431 145 24.0 1.00 20 2.33 10.5 432 146 63 21.6 0.96 22 2.24 10.1 414 139 23.4 1.00 20 2.31 10.4 427 144 23.6 1.00 19 2.31 10.4 428 144 23.0 0.94 23 2.35 10.6 441 154 24.9 0.97 21 2.41 10.9 455 159 25.1 0.99 20 2.42 10.9 456 159 67 23.1 0.78 19 2.32 10.5 437 152 25.0 0.81 18 2.39 10.8 451 157 25.2 0.83 17 2.40 10.8 452 157 24.5 0.76 20 2.43 11.0 460 164 26.5 0.79 18 2.50 11.3 475 169 26.8 0.80 18 2.51 11.4 476 169 71 24.7 0.59 15 2.41 10.9 456 162 26.7 0.61 14 2.48 11.2 470 167 27.0 0.62 14 2.49 11.2 471 168 Amps = outdoor unit amps (comp.+fan) kW = Total system power 26.4 0.75 21 2.34 10.3 417 158 28.6 0.78 20 2.41 10.6 430 163 28.9 0.80 19 2.42 10.7 431 164 71 26.6 0.6 16 2.3 10.2 412.5 156.8 28.8 0.6 15 2.4 10.5 425.3 161.6 29.1 0.6 15 2.4 10.6 426.6 162.1 115ºF Expanded Cooling Data — GSX130301L* / CA*F3030*6D*+EEP (cont.) 9 10 www.goodmanmfg.com 33.5 0.88 20 2.46 9.8 185 96 32.5 0.84 21 2.44 9.7 183 95 30.0 0.81 21 2.39 9.6 178 92 MBh S/T ∆T 1350 kW /anos Hi PR Lo PR MBh S/T ∆T 1200 kW /anos Hi PR Lo PR MBh S/T ∆T 1050 kW /anos Hi PR Lo PR 59 32.9 0.77 17 2.44 9.7 183 95 32.0 0.74 18 2.42 9.7 181 94 29.5 0.71 18 2.37 9.6 176 91 MBh S/T ∆T 1350 kW /anos Hi PR Lo PR MBh S/T ∆T 1200 kW /anos Hi PR Lo PR MBh S/T ∆T 1050 kW /anos Hi PR Lo PR Airflow 34.5 0.79 18 2.50 9.9 199 102 33.5 0.75 19 2.49 9.9 197 101 30.9 0.72 20 2.43 9.7 191 98 63 34.1 0.65 15 2.49 9.9 197 101 33.1 0.62 16 2.47 9.8 195 100 30.6 0.59 16 2.42 9.7 189 97 37.3 0.60 15 2.57 10.1 210 112 36.2 0.57 16 2.56 10.0 208 110 33.4 0.55 16 2.50 9.9 202 107 67 37.4 0.45 11 2.55 10.0 208 110 36.3 0.43 12 2.54 10.0 206 109 33.5 0.41 12 2.48 9.8 200 106 40.0 0.38 10 2.65 10.3 219 119 38.9 0.37 11 2.63 10.2 217 118 35.9 0.35 11 2.57 10.1 211 114 - 71 32.7 0.91 20 2.62 10.2 208 101 31.8 0.87 21 2.61 10.1 206 100 29.3 0.84 21 2.55 10.0 199 97 59 32.2 0.80 18 2.61 10.1 205 100 31.2 0.76 18 2.59 10.1 203 99 28.8 0.74 19 2.53 10.0 197 96 33.7 0.81 19 2.67 10.3 223 108 32.7 0.78 19 2.66 10.3 221 107 30.2 0.75 20 2.60 10.1 215 104 63 33.3 0.67 15 2.65 10.3 221 107 32.4 0.64 16 2.64 10.2 219 106 29.9 0.62 16 2.58 10.1 212 103 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 75 36.4 0.62 15 2.75 10.5 236 118 35.4 0.59 16 2.73 10.5 234 117 32.7 0.57 16 2.67 10.3 227 113 67 36.5 0.46 12 2.73 10.5 234 117 35.5 0.44 12 2.71 10.4 231 116 32.7 0.43 12 2.65 10.3 224 112 39.1 0.40 11 2.83 10.7 246 126 38.0 0.38 11 2.81 10.7 244 124 35.1 0.36 11 2.75 10.5 236 121 - 71 31.9 0.93 20 2.77 10.7 236 105 31.0 0.89 21 2.75 10.6 234 104 28.6 0.86 22 2.69 10.5 227 101 59 31.4 0.82 18 2.75 10.6 234 104 30.5 0.78 18 2.73 10.6 231 103 28.1 0.76 19 2.67 10.4 224 100 63 67 35.6 0.63 15 2.91 11.0 268 123 34.5 0.60 16 2.89 11.0 266 121 31.9 0.58 16 2.82 10.8 258 118 35.7 0.48 12 2.88 11.0 266 121 34.6 0.45 12 2.86 10.9 263 120 31.9 0.44 12 2.80 10.7 255 116 38.2 0.41 11 2.99 11.3 280 130 37.1 0.39 11 2.97 11.2 277 129 34.2 0.37 11 2.90 11.0 269 125 - 71 59 31.1 0.96 20 2.90 11.1 269 111 30.2 0.92 21 2.88 11.0 266 110 27.9 0.89 22 2.81 10.8 258 106 30.6 0.85 18 2.88 11.0 266 110 29.7 0.81 18 2.86 11.0 264 109 27.4 0.78 19 2.79 10.8 256 105 34.7 0.65 15 3.04 11.4 306 129 33.7 0.62 16 3.02 11.4 303 127 31.1 0.60 16 2.95 11.2 293 124 32.1 0.86 19 2.96 11.2 289 118 31.1 0.82 20 2.94 11.2 287 117 28.7 0.79 20 2.87 11.0 278 113 67 34.8 0.49 12 3.02 11.4 302 127 33.8 0.47 12 3.00 11.3 299 126 31.2 0.45 12 2.93 11.1 291 122 63 31.7 0.71 15 2.94 11.2 286 117 30.8 0.68 16 2.91 11.1 284 116 28.4 0.65 16 2.85 10.9 275 112 Shaded area reflects ACCA (TVA) conditions kW = Total system power 32.9 0.84 19 2.82 10.8 254 112 31.9 0.80 19 2.80 10.8 252 111 29.5 0.77 20 2.74 10.6 244 108 32.5 0.69 15 2.80 10.8 252 111 31.6 0.65 16 2.78 10.7 249 110 29.2 0.63 16 2.72 10.5 242 107 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 29.6 1.00 20 3.01 11.5 303 116 28.7 0.95 21 2.99 11.4 300 115 26.5 0.92 21 2.92 11.2 291 112 59 29.1 0.88 17 2.99 11.4 299 115 28.2 0.84 18 2.96 11.4 296 114 26.1 0.81 18 2.90 11.2 288 110 63 30.5 0.90 19 3.07 11.7 326 124 29.6 0.85 19 3.05 11.6 322 122 27.3 0.82 20 2.98 11.4 313 119 30.2 0.74 15 3.05 11.6 322 122 29.3 0.70 16 3.02 11.5 319 121 27.0 0.68 16 2.96 11.3 309 117 67 33.0 0.68 15 3.16 11.9 344 135 32.0 0.65 16 3.14 11.8 340 134 29.6 0.62 16 3.07 11.6 330 130 33.0 0.51 11 3.14 11.8 340 134 32.1 0.49 12 3.11 11.8 337 132 29.6 0.47 12 3.04 11.6 327 128 35.4 0.44 11 3.26 12.2 359 144 34.4 0.42 11 3.23 12.1 355 142 31.7 0.40 11 3.16 11.9 344 138 - 71 27.4 1.00 19 3.10 11.9 334 120 26.6 0.96 20 3.08 11.8 331 119 24.6 0.93 20 3.01 11.6 321 115 59 27.0 0.89 16 3.08 11.8 331 119 26.2 0.85 17 3.06 11.8 328 118 24.2 0.82 17 2.99 11.6 318 114 63 28.2 0.90 17 3.17 12.1 360 128 27.4 0.86 18 3.14 12.0 356 127 25.3 0.83 18 3.07 11.8 345 123 27.9 0.74 14 3.14 12.0 356 126 27.1 0.71 15 3.12 11.9 353 125 25.0 0.68 15 3.05 11.7 342 121 67 30.5 0.68 14 3.26 12.3 380 139 29.7 0.65 15 3.24 12.2 376 138 27.4 0.63 15 3.16 12.0 365 134 30.6 0.51 11 3.24 12.2 376 138 29.7 0.49 11 3.21 12.2 372 137 27.4 0.47 11 3.14 12.0 361 133 115 32.8 0.44 10 3.36 12.6 396 149 31.8 0.42 10 3.34 12.5 392 147 29.4 0.40 10 3.26 12.3 380 143 - 71 Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 37.3 0.42 11 3.14 11.7 319 137 36.2 0.40 11 3.11 11.6 316 136 33.4 0.39 11 3.04 11.4 306 132 - 71 105 Expanded Cooling Data — GSX130361E* / CA*F3636*6D* SS-GSX13 SS-GSX13 www.goodmanmfg.com 34.7 1.00 24 2.49 9.9 189 98 33.7 0.96 25 2.48 9.8 187 97 31.1 0.93 25 2.42 9.7 181 94 MBh S/T ∆T 1350 kW /anos Hi PR Lo PR MBh S/T ∆T 1200 kW /anos Hi PR Lo PR MBh S/T ∆T 1050 kW /anos Hi PR Lo PR 59 34.1 0.96 22 2.48 9.8 187 97 33.1 0.92 23 2.46 9.8 185 96 30.5 0.89 24 2.41 9.7 179 93 MBh S/T ∆T 1350 kW /anos Hi PR Lo PR MBh S/T ∆T 1200 kW /anos Hi PR Lo PR MBh S/T ∆T 1050 kW /anos Hi PR Lo PR Airflow 63 35.3 0.98 23 2.54 10.0 203 104 34.3 0.93 24 2.52 10.0 201 103 31.7 0.90 25 2.47 9.8 195 100 34.8 0.90 21 2.52 10.0 201 103 33.8 0.86 22 2.50 9.9 199 102 31.2 0.83 23 2.45 9.8 193 99 67 37.0 0.88 22 2.61 10.2 214 114 35.9 0.84 23 2.59 10.1 212 113 33.2 0.81 24 2.54 10.0 206 109 37.2 0.74 19 2.59 10.1 212 113 36.1 0.70 19 2.57 10.1 210 112 33.3 0.68 20 2.52 9.9 204 108 39.5 0.71 19 2.68 10.4 224 121 38.3 0.68 20 2.67 10.3 221 120 35.4 0.66 20 2.61 10.2 215 116 71 39.8 0.6 15 2.7 10.3 221.5 120.0 38.6 0.5 16 2.6 10.3 219.3 118.8 35.6 0.5 16 2.6 10.1 212.7 115.3 33.9 1.00 23 2.66 10.3 212 104 32.9 1.00 25 2.64 10.2 210 103 30.3 0.96 26 2.59 10.1 203 99 59 33.3 1.00 23 2.64 10.2 210 103 32.3 0.95 24 2.62 10.2 208 102 29.8 0.92 24 2.57 10.0 201 98 63 34.5 1.00 24 2.71 10.4 228 110 33.5 0.96 25 2.69 10.4 226 109 30.9 0.93 25 2.64 10.2 219 106 34.0 0.94 22 2.69 10.4 226 109 33.0 0.89 23 2.67 10.3 223 108 30.5 0.86 23 2.62 10.2 217 105 67 36.2 0.91 22 2.79 10.6 241 120 35.1 0.87 23 2.77 10.6 238 119 32.4 0.84 24 2.71 10.4 231 115 36.3 0.76 19 2.77 10.6 238 119 35.3 0.73 20 2.75 10.5 236 118 32.6 0.70 20 2.69 10.4 229 114 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 38.6 0.74 19 2.87 10.8 251 128 37.5 0.71 20 2.85 10.8 249 127 34.6 0.68 21 2.79 10.6 241 123 71 38.8 0.57 15 2.85 10.8 249 127 37.7 0.54 16 2.83 10.7 246 126 34.8 0.52 16 2.77 10.6 239 122 33.1 1.00 23 2.81 10.8 241 108 32.1 1.00 25 2.79 10.7 238 107 29.6 0.99 26 2.73 10.6 231 103 59 32.5 1.00 22 2.79 10.7 238 107 31.5 0.98 24 2.77 10.7 236 105 29.1 0.94 24 2.71 10.5 229 102 63 67 35.3 0.94 22 2.95 11.1 274 125 34.3 0.89 23 2.93 11.1 271 124 31.6 0.86 24 2.86 10.9 263 120 35.5 0.78 19 2.93 11.1 271 124 34.4 0.75 20 2.91 11.0 268 123 31.8 0.72 20 2.84 10.8 260 119 71 37.7 0.76 19 3.04 11.4 285 133 36.6 0.72 20 3.02 11.3 283 132 33.7 0.70 21 2.95 11.1 274 128 37.9 0.6 15 3.0 11.3 282.7 131.8 36.8 0.6 16 3.0 11.3 279.9 130.5 34.0 0.5 16 2.9 11.1 271.5 126.6 59 32.3 1.00 22 2.94 11.2 274 113 31.3 1.00 24 2.92 11.1 272 112 28.9 1.00 25 2.86 11.0 263 109 31.7 1.00 22 2.92 11.1 272 112 30.8 1.00 24 2.90 11.1 269 111 28.4 0.97 24 2.84 10.9 261 107 Shaded area reflects AHRI conditions kW = Total system power 33.7 1.00 23 2.87 10.9 259 114 32.7 0.99 25 2.85 10.9 257 113 30.2 0.95 25 2.78 10.7 249 110 33.2 0.96 22 2.85 10.9 257 113 32.2 0.92 23 2.82 10.8 254 112 29.8 0.88 23 2.76 10.6 246 109 63 32.9 1.00 22 3.00 11.4 295 120 31.9 1.00 24 2.98 11.3 292 119 29.5 0.98 25 2.91 11.1 284 115 32.4 1.00 22 2.98 11.3 292 119 31.4 0.95 23 2.96 11.2 289 118 29.0 0.91 23 2.89 11.1 281 114 67 34.4 0.97 23 3.09 11.6 312 131 33.4 0.92 24 3.07 11.5 309 130 30.9 0.89 24 3.00 11.3 299 126 34.6 0.81 19 3.07 11.5 309 130 33.6 0.77 20 3.05 11.5 306 129 31.0 0.74 20 2.98 11.3 296 125 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 30.6 1.00 21 3.06 11.6 309 118 29.7 1.00 23 3.03 11.5 306 117 27.5 1.00 24 2.96 11.4 296 114 59 30.1 1.00 21 3.03 11.5 306 117 29.2 1.00 22 3.01 11.5 303 116 27.0 1.01 24 2.94 11.3 293 113 31.2 1.00 21 3.12 11.8 332 126 30.3 1.00 23 3.09 11.7 329 125 28.0 1.00 25 3.02 11.5 319 121 63 30.8 1.00 21 3.09 11.7 329 125 29.9 0.98 22 3.07 11.7 326 124 27.6 0.95 23 3.00 11.5 316 120 32.7 1.00 22 3.21 12.0 351 138 31.8 0.96 23 3.19 12.0 347 136 29.3 0.92 24 3.11 11.7 337 132 67 32.9 0.84 19 3.19 12.0 347 136 31.9 0.80 20 3.16 11.9 344 135 29.5 0.77 20 3.09 11.7 333 131 34.9 0.81 19 3.31 12.3 366 147 33.9 0.78 20 3.28 12.2 362 145 31.3 0.75 20 3.21 12.0 351 141 71 35.1 0.6 15 3.3 12.2 362.2 145.1 34.1 0.6 16 3.3 12.2 358.6 143.6 31.5 0.6 16 3.2 11.9 347.8 139.3 28.4 1.00 19 3.15 12.0 341 123 27.6 1.00 21 3.13 12.0 338 121 25.4 1.00 22 3.06 11.8 327 118 59 27.9 1.00 19 3.13 12.0 338 121 27.1 1.00 21 3.10 11.9 334 120 25.0 1.02 22 3.03 11.7 324 117 28.9 1.00 20 3.22 12.2 367 130 28.1 1.00 22 3.19 12.1 363 129 25.9 1.00 23 3.12 11.9 352 125 63 28.5 1.00 19 3.19 12.1 363 129 27.7 0.99 21 3.17 12.1 360 128 25.5 0.95 21 3.10 11.9 349 124 30.3 1.00 21 3.31 12.5 387 142 29.4 0.96 22 3.29 12.4 384 141 27.2 0.93 22 3.21 12.2 372 137 67 30.5 0.84 18 3.29 12.4 384 141 29.6 0.81 18 3.26 12.3 380 140 27.3 0.78 19 3.19 12.1 368 135 115ºF 32.3 0.82 18 3.42 12.7 404 152 31.4 0.78 19 3.39 12.7 400 150 29.0 0.75 19 3.31 12.5 388 146 71 32.6 0.63 14 3.39 12.7 400 150 31.6 0.60 15 3.36 12.6 396 149 29.2 0.58 15 3.29 12.4 384 144 Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 36.7 0.78 20 3.19 11.8 325 140 35.7 0.75 20 3.16 11.8 322 138 32.9 0.72 21 3.09 11.6 312 134 71 37.0 0.60 15 3.16 11.8 322 138 35.9 0.58 16 3.14 11.7 319 137 33.2 0.55 16 3.07 11.5 309 133 105ºF Expanded Cooling Data — GSX130361E* / CA*F3636*6D* (cont.) 11 12 www.goodmanmfg.com 36.6 0.78 21 2.80 10.8 212 102 39.7 0.81 21 2.87 11.0 218 105 40.9 0.85 20 2.89 11.1 220 106 MBh S/T ∆T 1225 kW Amps Hi PR Lo PR MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1575 kW Amps Hi PR Lo PR 59 36.0 0.69 19 2.78 10.7 209 101 39.0 0.71 18 2.84 10.9 216 104 40.2 0.75 18 2.87 11.0 218 105 MBh S/T ∆T 1225 kW Amps Hi PR Lo PR MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1575 kW Amps Hi PR Lo PR Airflow 63 37.7 0.70 20 2.86 11.0 228 108 40.8 0.72 19 2.92 11.3 235 112 42.1 0.76 19 2.94 11.4 237 113 37.3 0.57 16 2.84 10.9 225 107 40.4 0.59 16 2.90 11.2 232 111 41.6 0.62 15 2.92 11.3 235 112 67 40.8 0.53 16 2.94 11.3 240 118 44.2 0.55 16 3.01 11.7 248 122 45.5 0.57 15 3.03 11.8 250 123 40.9 0.40 12 2.92 11.2 238 117 44.3 0.41 12 2.98 11.6 245 121 45.6 0.43 11 3.01 11.7 248 122 43.8 0.34 11 3.03 11.8 251 126 47.4 0.35 11 3.10 12.1 259 130 48.9 0.37 11 3.12 12.2 261 131 - 71 35.8 0.81 22 3.00 11.6 237 108 38.7 0.84 21 3.07 11.9 245 111 39.9 0.88 20 3.09 12.0 247 112 59 35.2 0.71 19 2.98 11.5 235 106 38.1 0.74 18 3.05 11.8 242 110 39.2 0.77 18 3.07 11.9 245 111 63 36.8 0.72 20 3.06 11.9 256 114 39.9 0.75 20 3.13 12.2 263 118 41.1 0.79 19 3.15 12.3 266 119 36.4 0.59 16 3.04 11.8 253 113 39.5 0.62 16 3.11 12.1 261 117 40.7 0.65 15 3.13 12.2 263 118 67 39.9 0.55 16 3.15 12.2 270 125 43.2 0.57 16 3.22 12.6 278 129 44.5 0.60 15 3.25 12.7 281 130 39.9 0.41 12 3.13 12.1 267 124 43.3 0.43 12 3.20 12.5 275 127 44.6 0.45 12 3.22 12.6 278 129 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 42.8 0.35 11 3.24 12.7 281 133 46.3 0.37 11 3.32 13.0 290 137 47.7 0.38 11 3.35 13.2 293 139 - 71 63 35.9 0.74 20 3.24 12.9 291 119 38.9 0.77 20 3.31 13.2 300 123 40.1 0.81 19 3.34 13.3 303 124 35.6 0.61 16 3.21 12.7 288 118 38.5 0.63 16 3.29 13.1 297 121 39.7 0.66 15 3.31 13.2 300 123 67 38.9 0.56 16 3.33 13.3 307 130 42.2 0.58 16 3.41 13.6 316 134 43.4 0.61 15 3.44 13.8 320 135 39.0 0.42 12 3.31 13.2 304 129 42.2 0.44 12 3.39 13.5 313 132 43.5 0.46 12 3.41 13.6 316 134 41.8 0.36 11 3.44 13.8 320 138 45.2 0.37 11 3.52 14.1 330 143 46.6 0.39 11 3.55 14.3 333 144 - 71 59 34.1 0.86 22 3.33 13.4 308 117 36.9 0.89 22 3.41 13.8 317 121 38.0 0.93 21 3.43 13.9 320 122 33.5 0.75 19 3.30 13.3 304 116 36.3 0.78 19 3.38 13.7 314 120 37.4 0.82 18 3.41 13.8 317 121 Shaded area reflects ACCA (TVA) conditions 34.9 0.83 22 3.17 12.6 270 112 37.8 0.86 21 3.25 12.9 278 115 39.0 0.90 21 3.27 13.0 281 116 59 34.3 0.73 19 3.15 12.5 267 111 37.2 0.76 18 3.22 12.8 276 114 38.3 0.79 18 3.25 12.9 278 115 38.0 0.58 17 3.50 14.2 350 136 41.1 0.60 16 3.58 14.6 360 141 42.4 0.63 16 3.61 14.7 364 142 35.1 0.77 20 3.39 13.7 331 125 38.0 0.79 20 3.48 14.1 341 129 39.1 0.83 19 3.50 14.2 345 130 67 38.0 0.44 12 3.47 14.0 346 135 41.2 0.45 12 3.55 14.4 357 139 42.4 0.47 12 3.58 14.6 360 141 63 34.7 0.63 16 3.37 13.6 328 124 37.6 0.65 16 3.45 14.0 338 127 38.7 0.68 15 3.48 14.1 341 129 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 40.7 0.37 11 3.61 14.7 365 145 44.1 0.39 11 3.70 15.1 376 150 45.5 0.41 11 3.72 15.2 380 151 - 71 32.4 0.89 22 3.46 14.2 346 123 35.1 0.92 21 3.54 14.6 357 127 36.1 0.97 20 3.57 14.8 360 128 59 31.8 0.78 19 3.43 14.1 343 122 34.5 0.81 18 3.51 14.5 353 126 35.5 0.85 18 3.54 14.6 357 127 33.3 0.79 20 3.53 14.6 372 131 36.1 0.82 20 3.61 15.0 384 135 37.2 0.86 19 3.64 15.1 388 136 63 33.0 0.65 16 3.50 14.5 369 130 35.7 0.68 16 3.58 14.9 380 134 36.8 0.71 15 3.61 15.0 384 135 36.1 0.60 16 3.64 15.1 393 143 39.1 0.62 16 3.73 15.5 405 147 40.2 0.65 15 3.76 15.6 409 149 67 36.1 0.45 12 3.61 14.9 389 141 39.1 0.47 12 3.70 15.3 401 146 40.3 0.49 12 3.73 15.5 405 147 105ºF 30.0 0.90 20 3.57 15.1 382 127 32.5 0.93 20 3.66 15.5 394 131 33.4 0.97 19 3.68 15.6 398 133 59 29.5 0.79 17 3.54 14.9 378 126 31.9 0.82 17 3.63 15.4 390 130 32.9 0.86 16 3.66 15.5 394 131 30.9 0.80 19 3.64 15.4 411 135 33.4 0.83 18 3.73 15.9 424 140 34.4 0.87 18 3.76 16.0 428 141 63 30.5 0.66 15 3.61 15.3 407 134 33.1 0.68 15 3.70 15.7 420 138 34.1 0.72 14 3.73 15.9 424 140 33.4 0.61 15 3.76 15.9 434 148 36.2 0.63 15 3.85 16.4 448 152 37.3 0.66 14 3.88 16.5 452 154 67 33.5 0.46 11 3.73 15.8 430 146 36.3 0.47 11 3.82 16.2 443 151 37.3 0.50 11 3.85 16.4 448 152 35.8 0.39 10 3.88 16.5 453 157 38.8 0.40 10 3.97 17.0 467 162 40.0 0.42 10 4.00 17.2 472 164 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 38.7 0.39 11 3.75 15.6 410 152 41.9 0.40 11 3.84 16.1 423 157 43.2 0.42 11 3.87 16.2 427 158 - 71 115ºF Expanded Cooling Data — GSX130421B* / CA*F3642*6B* SS-GSX13 SS-GSX13 www.goodmanmfg.com 37.9 0.90 26 2.84 10.9 216 104 41.1 0.93 25 2.91 11.2 223 107 42.3 0.98 24 2.93 11.3 225 108 MBh S/T ∆T 1225 kW Amps Hi PR Lo PR MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1575 kW Amps Hi PR Lo PR 59 37.3 0.86 24 2.82 10.8 214 103 40.4 0.89 24 2.89 11.1 220 106 41.6 0.93 23 2.91 11.2 223 107 MBh S/T ∆T 1225 kW Amps Hi PR Lo PR MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1575 kW Amps Hi PR Lo PR Airflow 63 38.6 0.87 25 2.90 11.2 232 110 41.9 0.90 25 2.96 11.5 240 114 43.1 0.94 24 2.99 11.6 242 115 38.1 0.80 23 2.88 11.1 230 109 41.3 0.83 23 2.94 11.4 237 113 42.5 0.87 22 2.96 11.5 240 114 67 40.5 0.78 24 2.98 11.6 245 121 43.9 0.81 23 3.05 11.9 253 124 45.2 0.85 22 3.07 12.0 255 126 40.7 0.65 20 2.96 11.4 243 119 44.1 0.68 20 3.03 11.8 250 123 45.4 0.71 19 3.05 11.9 253 124 43.2 0.63 21 3.07 12.0 256 128 46.8 0.66 20 3.14 12.3 264 132 48.2 0.69 19 3.17 12.4 266 134 71 43.5 0.49 16 3.05 11.9 253 127 47.1 0.51 16 3.12 12.2 261 131 48.5 0.53 15 3.14 12.3 264 132 37.0 0.93 26 3.04 11.8 242 110 40.1 0.96 25 3.11 12.1 250 113 41.3 1.00 24 3.14 12.2 252 114 59 36.4 0.89 24 3.02 11.7 240 109 39.4 0.92 24 3.09 12.0 247 112 40.6 0.96 23 3.11 12.1 250 113 63 37.7 0.90 25 3.11 12.1 261 117 40.9 0.93 25 3.18 12.4 269 120 42.1 0.98 24 3.20 12.5 271 122 37.2 0.83 23 3.08 12.0 258 116 40.3 0.86 23 3.15 12.3 266 119 41.5 0.90 22 3.18 12.4 269 120 67 39.5 0.81 24 3.20 12.5 275 127 42.8 0.84 24 3.27 12.8 284 131 44.1 0.88 23 3.30 12.9 287 133 39.7 0.68 20 3.17 12.4 273 126 43.1 0.70 20 3.25 12.7 281 130 44.3 0.74 19 3.27 12.8 284 131 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 42.2 0.66 21 3.29 12.9 287 136 45.7 0.68 20 3.37 13.3 296 140 47.1 0.71 20 3.40 13.4 299 141 71 42.5 0.51 16 3.27 12.8 284 134 46.0 0.52 16 3.35 13.2 293 139 47.4 0.55 15 3.37 13.3 296 140 63 36.9 0.92 25 3.29 13.1 297 121 39.9 0.95 25 3.36 13.5 306 125 41.1 1.00 24 3.39 13.6 309 126 36.3 0.85 23 3.26 13.0 294 120 39.3 0.88 23 3.34 13.3 303 124 40.5 0.93 22 3.36 13.5 306 125 67 38.6 0.83 24 3.39 13.5 313 132 41.8 0.86 24 3.47 13.9 323 137 43.1 0.90 23 3.49 14.0 326 138 38.8 0.69 20 3.36 13.4 310 131 42.0 0.72 20 3.44 13.8 320 135 43.3 0.75 19 3.47 13.9 323 137 71 41.2 0.67 21 3.49 14.0 327 141 44.6 0.70 20 3.58 14.4 337 145 45.9 0.73 20 3.60 14.5 340 147 41.5 0.52 16 3.46 13.9 323 140 44.9 0.54 16 3.55 14.3 333 144 46.3 0.56 15 3.58 14.4 337 145 Shaded area reflects AHRI conditions 36.2 0.95 26 3.22 12.8 276 114 39.2 0.99 25 3.30 13.1 284 118 40.3 1.00 24 3.32 13.3 287 119 59 35.5 0.91 24 3.20 12.7 273 113 38.5 0.94 24 3.27 13.0 281 116 39.6 1.00 23 3.30 13.1 284 118 35.3 0.98 26 3.38 13.6 314 120 38.2 1.00 25 3.46 14.0 324 123 39.4 1.00 23 3.49 14.2 327 125 34.7 0.94 24 3.35 13.5 311 119 37.6 0.97 24 3.43 13.9 320 122 38.7 1.00 23 3.46 14.0 324 123 59 36.0 0.95 26 3.45 14.0 338 127 39.0 0.98 25 3.53 14.4 348 131 40.1 1.00 23 3.56 14.5 352 133 35.4 0.88 23 3.42 13.8 334 126 38.4 0.91 23 3.50 14.2 345 130 39.5 0.96 22 3.53 14.4 348 131 63 37.7 0.86 24 3.55 14.4 357 139 40.8 0.89 24 3.64 14.8 368 143 42.0 0.93 23 3.67 15.0 371 145 37.8 0.72 20 3.53 14.3 353 138 41.0 0.74 20 3.61 14.7 364 142 42.2 0.78 19 3.64 14.8 368 143 67 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 40.2 0.70 21 3.66 15.0 372 148 43.5 0.72 21 3.75 15.4 383 153 44.8 0.76 20 3.78 15.5 387 154 71 40.5 0.54 16 3.64 14.8 368 147 43.8 0.56 16 3.72 15.2 380 151 45.1 0.58 15 3.75 15.4 383 153 33.5 1.00 25 3.51 14.5 353 126 36.3 1.00 24 3.60 14.9 364 129 37.4 1.00 22 3.62 15.0 368 131 59 32.9 0.97 24 3.48 14.4 350 124 35.7 1.00 23 3.57 14.8 360 128 36.7 1.00 21 3.60 14.9 364 129 34.2 0.99 25 3.58 14.9 380 134 37.0 1.00 24 3.67 15.3 392 138 38.1 1.00 22 3.70 15.4 396 139 63 33.6 0.91 23 3.56 14.7 376 132 36.5 0.95 23 3.64 15.1 388 136 37.6 1.00 22 3.67 15.3 392 138 35.8 0.89 24 3.70 15.3 401 146 38.8 0.92 23 3.79 15.8 414 150 39.9 0.97 23 3.82 15.9 418 152 67 36.0 0.74 20 3.67 15.2 397 144 39.0 0.77 20 3.76 15.6 410 149 40.1 0.81 19 3.79 15.8 414 150 105ºF 31.0 1.00 23 3.63 15.4 390 130 33.6 1.00 22 3.71 15.8 402 134 34.6 1.00 20 3.74 15.9 406 135 59 30.5 0.98 22 3.60 15.2 386 129 33.0 1.00 22 3.68 15.6 398 133 34.0 1.00 20 3.71 15.8 402 134 31.6 0.99 24 3.70 15.7 420 138 34.3 1.00 23 3.79 16.2 433 142 35.3 1.00 21 3.82 16.3 437 144 63 31.2 0.92 22 3.67 15.6 416 137 33.8 0.96 21 3.76 16.0 428 141 34.8 1.00 20 3.79 16.2 433 142 33.1 0.90 22 3.82 16.2 443 151 35.9 0.93 22 3.91 16.7 457 155 37.0 0.98 21 3.94 16.9 462 157 67 33.3 0.75 19 3.79 16.1 439 149 36.1 0.78 18 3.88 16.5 452 154 37.2 0.82 18 3.91 16.7 457 155 35.4 0.73 19 3.94 16.8 462 161 38.3 0.75 19 4.04 17.3 477 166 39.4 0.79 18 4.07 17.5 481 167 71 35.6 0.56 15 3.91 16.7 458 159 38.6 0.58 15 4.01 17.2 472 164 39.7 0.61 14 4.04 17.3 477 166 Amps = outdoor unit amps (comp.+fan) kW = Total system power 38.2 0.72 21 3.81 15.9 418 155 41.3 0.75 20 3.91 16.4 431 160 42.6 0.78 20 3.94 16.5 436 162 71 38.4 0.56 16 3.78 15.8 414 154 41.6 0.58 16 3.88 16.2 427 158 42.9 0.60 15 3.91 16.4 431 160 115ºF Expanded Cooling Data — GSX130421B* / CA*F3642*6B* (cont.) 13 14 www.goodmanmfg.com 41.1 0.81 22 3.19 11.7 217 105 44.5 0.84 21 3.26 12.1 223 109 45.8 0.88 21 3.29 12.2 226 110 MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR MBh S/T ∆T 1800 kW Amps Hi PR Lo PR 59 40.4 0.71 19 3.17 11.6 215 104 43.8 0.73 18 3.24 12.0 221 108 45.1 0.77 18 3.26 12.1 223 109 MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR MBh S/T ∆T 1800 kW Amps Hi PR Lo PR Airflow 63 42.3 0.72 20 3.25 12.0 233 112 45.8 0.75 20 3.33 12.4 240 116 47.2 0.78 19 3.35 12.5 243 117 41.9 0.59 16 3.23 11.9 231 111 45.4 0.61 16 3.30 12.3 238 114 46.7 0.64 15 3.33 12.4 240 116 67 45.8 0.55 16 3.35 12.4 246 122 49.6 0.57 16 3.42 12.8 254 126 51.1 0.59 15 3.45 12.9 256 127 45.9 0.41 12 3.32 12.3 244 121 49.7 0.43 12 3.40 12.7 251 125 51.2 0.45 12 3.42 12.8 254 126 49.1 0.35 11 3.45 12.9 257 130 53.2 0.36 11 3.53 13.2 265 134 54.8 0.38 11 3.55 13.4 267 136 - 71 40.1 0.83 22 3.42 12.7 243 111 43.5 0.87 22 3.50 13.1 251 115 44.8 0.91 21 3.52 13.2 253 116 59 39.5 0.73 19 3.39 12.6 241 110 42.7 0.76 19 3.47 12.9 248 114 44.0 0.80 18 3.50 13.0 251 115 63 41.3 0.75 20 3.49 13.0 262 118 44.8 0.77 20 3.57 13.4 270 122 46.1 0.81 19 3.59 13.5 272 123 40.9 0.61 16 3.46 12.9 259 117 44.3 0.64 16 3.54 13.2 267 121 45.6 0.67 16 3.57 13.4 270 122 67 44.7 0.56 17 3.59 13.4 276 129 48.4 0.59 16 3.68 13.8 285 133 49.9 0.61 16 3.70 13.9 288 135 44.8 0.42 12 3.56 13.3 274 128 48.5 0.44 12 3.65 13.7 282 132 50.0 0.46 12 3.67 13.8 285 133 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 48.0 0.36 11 3.70 13.9 288 138 52.0 0.38 11 3.79 14.3 297 142 53.6 0.40 11 3.82 14.5 300 143 - 71 63 40.3 0.77 20 3.69 14.1 298 123 43.7 0.79 20 3.78 14.5 307 127 45.0 0.83 19 3.81 14.7 310 128 39.9 0.63 16 3.66 14.0 295 122 43.2 0.65 16 3.75 14.4 304 126 44.5 0.68 16 3.78 14.5 307 127 67 43.7 0.58 17 3.80 14.6 314 134 47.3 0.60 16 3.90 15.0 324 139 48.7 0.63 16 3.93 15.1 327 140 43.7 0.44 13 3.77 14.5 311 133 47.4 0.45 12 3.87 14.9 321 137 48.8 0.47 12 3.90 15.0 324 139 46.8 0.37 11 3.92 15.1 328 143 50.8 0.39 11 4.02 15.6 338 148 52.3 0.41 11 4.05 15.7 341 149 - 71 59 38.2 0.88 22 3.79 14.7 315 122 41.4 0.92 22 3.89 15.2 325 125 42.6 0.96 21 3.92 15.3 328 127 37.6 0.78 19 3.77 14.6 312 120 40.7 0.81 19 3.86 15.0 321 124 41.9 0.85 18 3.89 15.2 325 125 Shaded area reflects ACCA (TVA) conditions 39.2 0.86 22 3.62 13.8 277 116 42.4 0.89 22 3.70 14.2 285 119 43.7 0.93 21 3.73 14.3 288 120 59 38.5 0.75 19 3.59 13.7 274 115 41.7 0.78 19 3.67 14.1 282 118 43.0 0.82 18 3.70 14.2 285 119 42.6 0.60 17 3.99 15.6 358 141 46.1 0.62 16 4.09 16.1 369 146 47.5 0.65 16 4.12 16.2 373 147 39.3 0.79 20 3.87 15.1 339 129 42.6 0.82 20 3.97 15.5 349 133 43.9 0.86 19 4.00 15.7 353 135 67 42.7 0.45 13 3.96 15.5 354 140 46.2 0.47 12 4.06 15.9 365 144 47.6 0.49 12 4.09 16.0 369 146 63 38.9 0.65 17 3.84 15.0 336 128 42.2 0.67 16 3.94 15.4 346 132 43.5 0.71 16 3.97 15.5 349 133 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 45.7 0.38 12 4.12 16.2 373 150 49.5 0.40 11 4.22 16.7 385 155 51.0 0.42 11 4.26 16.8 389 157 - 71 36.3 0.92 22 3.95 15.7 354 127 39.3 0.95 21 4.04 16.1 365 131 40.5 1.00 21 4.07 16.3 369 133 59 35.7 0.81 19 3.91 15.5 351 126 38.7 0.84 19 4.01 16.0 362 130 39.8 0.88 18 4.04 16.1 365 131 37.4 0.82 20 4.03 16.1 381 136 40.5 0.85 20 4.13 16.5 393 140 41.7 0.89 19 4.16 16.7 397 141 63 37.0 0.67 16 4.00 15.9 377 134 40.1 0.70 16 4.09 16.4 389 138 41.3 0.73 15 4.13 16.5 393 140 40.5 0.62 16 4.15 16.6 403 148 43.8 0.64 16 4.26 17.1 415 153 45.1 0.67 16 4.29 17.2 419 154 67 40.5 0.47 12 4.12 16.5 399 146 43.9 0.48 12 4.22 16.9 411 151 45.2 0.51 12 4.26 17.1 415 152 105ºF 33.6 0.92 20 4.08 16.6 391 132 36.4 0.96 20 4.18 17.1 404 136 37.5 1.00 19 4.21 17.3 408 137 59 33.1 0.81 18 4.04 16.5 388 130 35.8 0.84 17 4.14 16.9 400 134 36.9 0.88 17 4.18 17.1 404 136 34.6 0.83 19 4.16 17.0 421 140 37.5 0.86 18 4.26 17.5 434 145 38.6 0.90 18 4.30 17.7 439 146 63 34.3 0.68 15 4.13 16.9 417 139 37.1 0.70 15 4.23 17.4 430 143 38.2 0.74 14 4.26 17.5 434 144 37.5 0.63 15 4.29 17.6 445 153 40.6 0.65 15 4.40 18.1 459 158 41.8 0.68 15 4.44 18.3 463 159 67 37.5 0.47 12 4.26 17.4 440 151 40.7 0.49 11 4.36 17.9 454 156 41.9 0.51 11 4.40 18.1 459 158 40.2 0.40 11 4.43 18.3 464 163 43.6 0.42 10 4.54 18.8 478 168 44.9 0.44 10 4.58 19.0 483 170 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 43.4 0.40 11 4.29 17.2 420 158 47.0 0.41 11 4.39 17.7 433 162 48.5 0.43 11 4.43 17.9 437 164 - 71 115ºF Expanded Cooling Data — GSX130481B* / CA*F4860*6B* SS-GSX13 SS-GSX13 www.goodmanmfg.com 42.5 0.93 26 3.24 12.0 221 108 46.1 0.96 25 3.31 12.3 228 111 47.5 1.00 24 3.34 12.4 230 112 MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR MBh S/T ∆T 1800 kW Amps Hi PR Lo PR 59 41.8 0.88 24 3.21 11.9 219 106 45.3 0.92 24 3.29 12.2 226 110 46.7 0.96 23 3.31 12.3 228 111 MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR MBh S/T ∆T 1800 kW Amps Hi PR Lo PR Airflow 63 43.4 0.89 25 3.30 12.2 238 114 47.0 0.93 25 3.38 12.6 245 118 48.4 0.97 24 3.40 12.7 248 119 42.7 0.83 23 3.28 12.1 236 113 46.3 0.86 23 3.35 12.5 243 117 47.7 0.90 22 3.38 12.6 245 118 67 45.4 0.81 24 3.40 12.6 251 125 49.2 0.84 24 3.48 13.0 259 129 50.7 0.88 23 3.50 13.1 262 130 45.6 0.67 20 3.37 12.5 249 124 49.5 0.70 20 3.45 12.9 256 127 50.9 0.73 19 3.48 13.0 259 129 48.5 0.65 21 3.50 13.1 262 133 52.5 0.68 20 3.58 13.5 270 137 54.1 0.71 20 3.61 13.6 273 138 71 48.8 0.50 16 3.47 13.0 259 132 52.9 0.52 16 3.56 13.4 267 136 54.4 0.55 15 3.58 13.5 270 137 41.5 0.96 26 3.47 12.9 248 114 45.0 1.00 26 3.55 13.3 256 117 46.4 1.00 24 3.58 13.4 258 118 59 40.8 0.92 25 3.44 12.8 246 112 44.2 0.95 24 3.52 13.2 253 116 45.6 1.00 23 3.55 13.3 256 117 63 42.4 0.93 26 3.54 13.2 267 121 45.9 0.96 25 3.62 13.6 275 125 47.3 1.00 24 3.65 13.7 278 126 41.7 0.86 24 3.51 13.1 264 120 45.2 0.89 23 3.59 13.5 272 123 46.6 0.93 22 3.62 13.6 275 125 67 44.4 0.84 24 3.65 13.7 282 132 48.1 0.87 24 3.73 14.1 291 136 49.5 0.91 23 3.76 14.2 294 137 44.6 0.70 20 3.62 13.6 279 131 48.3 0.72 20 3.70 13.9 288 135 49.7 0.76 19 3.73 14.1 291 136 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 47.3 0.68 21 3.76 14.2 294 140 51.3 0.70 21 3.85 14.6 303 145 52.8 0.74 20 3.88 14.7 306 146 71 47.7 0.52 16 3.73 14.1 291 139 51.6 0.54 16 3.82 14.5 300 143 53.2 0.57 15 3.85 14.6 303 145 63 41.3 0.95 26 3.75 14.4 304 126 44.8 0.98 25 3.84 14.8 313 129 46.1 1.00 24 3.87 14.9 316 131 40.7 0.88 24 3.72 14.3 301 124 44.1 0.91 23 3.81 14.7 310 128 45.5 0.96 22 3.84 14.8 313 129 67 43.3 0.86 24 3.86 14.9 321 137 46.9 0.89 24 3.96 15.3 331 141 48.3 0.93 23 3.99 15.4 334 143 43.5 0.72 20 3.83 14.7 317 136 47.2 0.74 20 3.93 15.2 327 140 48.6 0.78 19 3.96 15.3 331 141 71 46.2 0.70 21 3.99 15.4 334 146 50.1 0.72 21 4.08 15.9 345 151 51.6 0.76 20 4.11 16.0 348 152 46.5 0.54 16 3.95 15.3 331 145 50.4 0.56 16 4.05 15.7 341 149 51.9 0.58 15 4.08 15.9 345 151 Shaded area reflects AHRI conditions 40.6 0.98 26 3.67 14.0 282 118 43.9 1.00 25 3.76 14.4 291 122 45.3 1.00 23 3.79 14.6 294 123 59 39.9 0.94 25 3.65 13.9 279 117 43.2 0.97 24 3.73 14.3 288 120 44.5 1.00 23 3.76 14.4 291 122 59 39.6 1.00 26 3.85 15.0 321 124 42.9 1.00 25 3.95 15.4 331 128 44.2 1.00 23 3.98 15.6 335 129 38.9 0.97 25 3.82 14.9 318 123 42.1 1.00 24 3.92 15.3 328 127 43.4 1.00 22 3.95 15.4 331 128 63 40.3 0.98 26 3.94 15.4 346 132 43.7 1.00 25 4.03 15.8 356 136 45.0 1.00 23 4.06 16.0 360 137 39.7 0.91 24 3.90 15.2 342 131 43.1 0.94 23 4.00 15.7 353 135 44.3 1.00 23 4.03 15.8 356 136 67 42.2 0.88 25 4.06 15.9 365 144 45.8 0.92 24 4.16 16.4 376 148 47.1 0.96 23 4.19 16.5 380 150 42.5 0.74 21 4.03 15.8 362 143 46.0 0.77 20 4.12 16.2 373 147 47.4 0.80 19 4.16 16.4 376 148 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 45.1 0.72 21 4.19 16.5 381 153 48.8 0.74 21 4.29 17.0 393 158 50.3 0.78 20 4.32 17.1 397 160 71 45.4 0.55 16 4.15 16.3 377 152 49.2 0.57 16 4.26 16.8 389 157 50.6 0.60 16 4.29 17.0 393 158 37.6 1.00 25 4.01 16.0 361 130 40.7 1.00 23 4.11 16.4 373 134 42.0 1.00 21 4.14 16.6 376 135 59 36.9 1.01 24 3.98 15.8 358 129 40.0 1.00 23 4.07 16.3 369 133 41.2 1.00 21 4.11 16.4 373 134 38.3 1.00 25 4.09 16.4 389 138 41.5 1.00 24 4.19 16.8 401 143 42.8 1.00 22 4.23 17.0 405 144 63 37.8 0.94 23 4.06 16.2 385 137 40.9 0.98 23 4.16 16.7 397 141 42.1 1.00 22 4.19 16.8 401 143 40.1 0.92 24 4.22 16.9 411 151 43.5 0.95 24 4.33 17.4 423 156 44.8 1.00 23 4.36 17.6 428 157 67 40.3 0.77 20 4.19 16.8 407 149 43.7 0.80 20 4.29 17.3 419 154 45.0 0.83 19 4.33 17.4 423 156 105ºF 34.8 1.00 23 4.14 16.9 399 134 37.7 1.00 22 4.24 17.4 412 139 38.9 1.00 20 4.28 17.6 416 140 59 34.2 1.01 23 4.11 16.8 395 133 37.1 1.00 21 4.21 17.3 408 137 38.2 1.00 20 4.24 17.4 412 139 35.5 1.00 23 4.23 17.4 430 143 38.5 1.00 22 4.33 17.9 443 147 39.6 1.00 20 4.37 18.0 448 149 63 35.0 0.95 22 4.20 17.2 426 142 37.9 0.99 21 4.30 17.7 439 146 39.0 1.00 20 4.33 17.9 443 147 37.2 0.93 23 4.36 17.9 454 156 40.3 0.96 22 4.47 18.5 468 161 41.5 1.00 21 4.51 18.6 473 163 67 37.4 0.77 19 4.33 17.8 449 155 40.5 0.80 19 4.44 18.3 463 159 41.7 0.84 18 4.47 18.5 468 161 39.7 0.75 20 4.50 18.6 473 166 43.0 0.78 19 4.62 19.2 488 171 44.3 0.82 18 4.65 19.3 493 173 71 39.9 0.58 15 4.47 18.5 469 165 43.3 0.60 15 4.58 19.0 483 170 44.6 0.63 14 4.62 19.2 488 171 Amps = outdoor unit amps (comp.+fan) kW = Total system power 42.8 0.74 21 4.36 17.6 428 161 46.4 0.77 21 4.47 18.1 442 166 47.8 0.81 20 4.50 18.2 446 167 71 43.1 0.57 16 4.32 17.4 424 159 46.7 0.60 16 4.43 17.9 437 164 48.1 0.62 15 4.47 18.1 442 166 115ºF Expanded Cooling Data — GSX130481B* / CA*F4860*6B* (cont.) 15 16 www.goodmanmfg.com 50.9 0.76 24 3.90 14.6 231 103 55.1 0.79 23 3.99 15.0 238 106 56.8 0.83 22 4.02 15.1 241 107 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR 59 50.1 0.67 21 3.87 14.4 229 101 54.2 0.69 20 3.96 14.8 236 105 55.9 0.73 19 3.99 15.0 238 106 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR Airflow 63 52.4 0.68 22 3.98 14.9 249 109 56.8 0.71 21 4.07 15.3 256 112 58.5 0.74 20 4.11 15.5 259 114 51.9 0.56 18 3.95 14.8 246 108 56.2 0.58 17 4.04 15.2 254 111 57.9 0.61 16 4.07 15.3 256 112 67 56.7 0.51 18 4.10 15.4 263 119 61.5 0.53 17 4.20 15.8 271 123 63.3 0.56 16 4.23 16.0 274 124 56.8 0.39 13 4.07 15.3 260 118 61.6 0.40 13 4.17 15.7 268 122 63.4 0.42 12 4.20 15.8 271 123 60.9 0.33 12 4.23 16.0 274 127 66.0 0.34 12 4.33 16.4 282 131 67.9 0.36 11 4.37 16.6 285 132 - 71 49.7 0.79 24 4.19 15.8 259 108 53.9 0.82 23 4.29 16.2 267 112 55.5 0.86 22 4.33 16.4 270 113 59 48.9 0.69 21 4.16 15.6 257 107 53.0 0.72 20 4.26 16.1 265 111 54.6 0.75 19 4.29 16.2 267 112 63 51.2 0.70 22 4.28 16.1 279 115 55.5 0.73 21 4.38 16.6 288 119 57.1 0.77 20 4.42 16.8 291 120 50.7 0.58 18 4.24 16.0 276 114 54.9 0.60 17 4.35 16.4 285 118 56.5 0.63 16 4.38 16.6 288 119 67 55.4 0.53 18 4.41 16.7 295 126 60.0 0.55 17 4.52 17.2 304 130 61.8 0.58 16 4.56 17.3 307 131 55.5 0.40 14 4.38 16.5 292 125 60.1 0.42 13 4.48 17.0 301 128 62.0 0.44 12 4.52 17.2 304 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 59.5 0.34 13 4.55 17.3 307 134 64.4 0.36 12 4.66 17.8 317 138 66.4 0.37 11 4.70 18.0 320 139 - 71 63 50.0 0.72 22 4.54 17.6 317 120 54.1 0.75 21 4.65 18.1 327 123 55.8 0.79 20 4.69 18.2 331 125 49.5 0.59 18 4.50 17.4 314 119 53.6 0.62 17 4.62 17.9 324 122 55.2 0.65 16 4.65 18.1 327 123 67 54.1 0.55 18 4.68 18.1 335 131 58.6 0.57 17 4.80 18.7 346 135 60.4 0.59 16 4.84 18.8 349 136 54.2 0.41 14 4.65 18.0 332 129 58.7 0.43 13 4.76 18.5 342 133 60.5 0.45 12 4.80 18.7 346 135 58.1 0.35 13 4.84 18.8 350 139 62.9 0.36 12 4.96 19.4 360 144 64.8 0.38 11 5.00 19.6 364 145 - 71 59 47.3 0.83 24 4.67 18.3 336 118 51.3 0.86 23 4.79 18.9 346 122 52.8 0.91 22 4.83 19.0 350 123 46.6 0.73 21 4.63 18.2 333 117 50.4 0.76 20 4.75 18.7 343 121 52.0 0.80 19 4.79 18.9 346 122 Shaded area reflects ACCA (TVA) conditions 48.5 0.81 24 4.45 17.1 295 113 52.6 0.84 23 4.56 17.6 304 116 54.2 0.88 22 4.59 17.8 307 117 59 47.7 0.71 21 4.41 17.0 292 111 51.7 0.74 20 4.52 17.5 301 115 53.3 0.77 19 4.56 17.6 304 116 52.8 0.56 18 4.93 19.4 382 137 57.2 0.59 18 5.05 20.0 394 142 58.9 0.61 17 5.09 20.2 398 143 48.8 0.75 22 4.77 18.8 362 126 52.8 0.77 21 4.89 19.3 373 130 54.4 0.81 20 4.93 19.5 376 131 67 52.9 0.42 14 4.89 19.2 378 136 57.3 0.44 13 5.01 19.8 390 140 59.0 0.46 13 5.05 20.0 394 142 63 48.3 0.61 18 4.73 18.6 358 125 52.3 0.64 17 4.85 19.1 369 128 53.9 0.67 16 4.89 19.3 373 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 56.6 0.36 13 5.09 20.2 398 146 61.4 0.38 12 5.22 20.8 411 151 63.2 0.39 11 5.26 20.9 415 152 - 71 45.0 0.87 24 4.86 19.5 378 124 48.7 0.90 23 4.99 20.1 390 128 50.2 0.94 22 5.03 20.3 394 129 59 44.2 0.76 21 4.82 19.3 374 123 47.9 0.79 20 4.95 19.9 386 126 49.4 0.83 19 4.99 20.1 390 128 46.3 0.77 22 4.97 20.0 407 132 50.2 0.80 21 5.10 20.6 419 136 51.7 0.84 20 5.14 20.8 424 137 63 45.8 0.64 18 4.93 19.8 403 130 49.7 0.66 17 5.05 20.4 415 135 51.2 0.69 16 5.10 20.6 419 136 50.1 0.59 18 5.13 20.7 430 144 54.3 0.61 17 5.26 21.3 443 148 55.9 0.64 16 5.31 21.5 447 150 67 50.2 0.44 14 5.09 20.5 425 142 54.4 0.46 13 5.22 21.1 438 147 56.1 0.48 12 5.26 21.3 443 148 105ºF 41.7 0.87 22 5.03 20.7 418 128 45.1 0.91 21 5.16 21.3 431 132 46.5 0.95 20 5.20 21.5 435 133 59 41.0 0.77 19 4.99 20.5 413 127 44.4 0.80 19 5.12 21.1 426 131 45.7 0.83 18 5.16 21.3 430 132 42.9 0.78 21 5.14 21.2 449 136 46.5 0.81 20 5.27 21.8 463 141 47.9 0.85 19 5.32 22.0 468 142 63 42.5 0.64 17 5.10 21.0 445 135 46.0 0.66 16 5.23 21.6 459 139 47.4 0.70 15 5.27 21.8 463 141 46.4 0.59 17 5.31 21.9 475 149 50.3 0.61 16 5.44 22.6 489 153 51.8 0.64 15 5.49 22.8 494 155 67 46.5 0.44 13 5.26 21.7 470 147 50.4 0.46 12 5.40 22.4 484 152 51.9 0.48 12 5.44 22.6 489 153 49.8 0.38 12 5.48 22.8 495 159 54.0 0.39 11 5.63 23.5 510 163 55.6 0.41 11 5.67 23.7 515 165 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 53.8 0.38 12 5.30 21.5 448 153 58.3 0.39 12 5.44 22.1 462 158 60.0 0.41 11 5.48 22.3 466 160 - 71 115ºF Expanded Cooling Data — GSX130601B* / CA*F4961*6A* SS-GSX13 SS-GSX13 www.goodmanmfg.com 52.7 0.87 28 3.96 14.8 236 105 57.1 0.91 27 4.05 15.2 243 108 58.8 0.95 26 4.09 15.4 246 109 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR 59 51.8 0.83 26 3.93 14.7 234 104 56.1 0.86 25 4.02 15.1 241 107 57.8 0.91 24 4.05 15.2 243 108 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR Airflow 63 53.7 0.84 28 4.04 15.2 254 111 58.2 0.87 27 4.14 15.6 262 115 60.0 0.92 25 4.17 15.8 264 116 52.9 0.78 25 4.01 15.1 251 110 57.4 0.81 24 4.11 15.5 259 114 59.1 0.85 23 4.14 15.6 262 115 67 56.3 0.76 26 4.17 15.7 268 121 61.0 0.79 25 4.27 16.1 276 125 62.8 0.83 24 4.30 16.3 279 126 56.6 0.64 22 4.13 15.6 265 120 61.3 0.66 21 4.23 16.0 274 124 63.1 0.69 20 4.27 16.1 276 125 60.0 0.62 23 4.30 16.3 280 129 65.0 0.64 22 4.40 16.7 288 133 67.0 0.67 21 4.44 16.9 291 135 71 60.5 0.48 18 4.26 16.1 277 128 65.5 0.49 17 4.37 16.6 285 132 67.5 0.52 16 4.40 16.7 288 133 51.5 0.91 29 4.26 16.0 265 110 55.8 0.94 28 4.36 16.5 273 114 57.5 0.99 26 4.39 16.7 276 115 59 50.6 0.86 27 4.22 15.9 262 109 54.8 0.90 26 4.33 16.4 270 113 56.5 0.94 24 4.36 16.5 273 114 63 52.5 0.87 28 4.35 16.4 285 118 56.9 0.91 27 4.45 16.9 294 121 58.6 0.95 26 4.49 17.1 297 122 51.7 0.81 26 4.31 16.3 282 116 56.0 0.84 25 4.42 16.8 291 120 57.7 0.88 23 4.45 16.9 294 121 67 55.0 0.79 27 4.48 17.0 301 128 59.6 0.82 26 4.59 17.5 310 132 61.3 0.86 24 4.63 17.6 313 134 55.2 0.66 22 4.45 16.8 298 127 59.9 0.68 22 4.56 17.3 307 131 61.6 0.72 20 4.59 17.5 310 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 58.6 0.64 23 4.62 17.6 314 137 63.5 0.66 22 4.74 18.1 323 141 65.4 0.70 21 4.78 18.3 327 142 71 59.1 0.49 18 4.59 17.5 311 135 64.0 0.51 17 4.70 18.0 320 140 65.9 0.54 16 4.74 18.1 323 141 63 51.2 0.90 28 4.61 17.9 324 122 55.5 0.93 27 4.73 18.4 334 126 57.2 0.97 26 4.77 18.6 337 127 50.5 0.83 26 4.58 17.7 321 121 54.7 0.86 25 4.69 18.2 331 125 56.3 0.90 23 4.73 18.4 334 126 67 53.7 0.81 27 4.76 18.5 342 133 58.1 0.84 26 4.88 19.0 353 137 59.9 0.88 24 4.92 19.2 356 139 53.9 0.68 22 4.72 18.3 339 132 58.4 0.70 22 4.84 18.8 349 136 60.2 0.74 20 4.88 19.0 353 137 71 57.2 0.66 23 4.92 19.2 357 142 62.0 0.68 22 5.04 19.8 368 146 63.9 0.71 21 5.08 19.9 371 148 57.6 0.51 18 4.88 19.0 353 141 62.5 0.52 17 5.00 19.6 364 145 64.3 0.55 16 5.04 19.8 368 146 Shaded area reflects AHRI conditions 50.3 0.93 29 4.52 17.5 301 115 54.5 0.96 28 4.63 18.0 310 118 56.1 1.00 26 4.67 18.1 313 120 59 49.4 0.89 27 4.48 17.3 298 114 53.5 0.92 26 4.59 17.8 307 117 55.1 0.96 24 4.63 18.0 310 118 49.0 0.96 29 4.75 18.7 343 121 53.1 0.99 28 4.87 19.2 353 124 54.7 1.00 25 4.91 19.4 357 126 48.2 0.91 27 4.71 18.5 339 119 52.2 0.95 26 4.83 19.0 350 123 53.8 1.00 25 4.87 19.2 353 124 59 50.0 0.93 28 4.85 19.1 369 128 54.2 0.96 27 4.97 19.7 380 132 55.8 1.00 26 5.01 19.9 384 134 49.2 0.86 26 4.81 19.0 365 127 53.4 0.89 25 4.93 19.5 377 131 55.0 0.93 24 4.97 19.7 380 132 63 52.3 0.83 27 5.01 19.8 390 140 56.7 0.87 26 5.13 20.4 402 144 58.4 0.91 24 5.18 20.6 406 146 52.6 0.70 23 4.97 19.6 386 139 57.0 0.72 22 5.09 20.2 398 143 58.7 0.76 20 5.13 20.4 402 144 67 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 55.8 0.68 23 5.17 20.5 406 149 60.5 0.70 22 5.30 21.1 419 154 62.3 0.74 21 5.35 21.3 423 155 71 56.2 0.52 18 5.13 20.4 402 148 60.9 0.54 17 5.26 20.9 415 152 62.8 0.57 16 5.30 21.1 419 154 46.6 1.00 28 4.94 19.9 386 126 50.5 1.00 27 5.07 20.5 398 130 52.0 1.00 24 5.11 20.7 402 132 59 45.8 0.95 27 4.90 19.7 382 125 49.6 0.98 26 5.03 20.3 394 129 51.1 1.00 23 5.07 20.5 398 130 47.5 0.96 28 5.05 20.4 415 134 51.4 1.00 27 5.18 21.0 428 139 53.0 1.00 24 5.22 21.2 432 140 63 46.8 0.89 26 5.01 20.2 411 133 50.7 0.92 25 5.14 20.8 424 137 52.2 0.97 23 5.18 21.0 428 139 49.7 0.87 26 5.22 21.1 438 147 53.9 0.90 25 5.35 21.7 452 151 55.5 0.94 24 5.39 21.9 456 153 67 50.0 0.72 22 5.17 20.9 434 145 54.2 0.75 21 5.31 21.5 447 150 55.8 0.79 20 5.35 21.7 452 151 105ºF 43.1 1.00 26 5.11 21.1 426 131 46.7 1.00 25 5.24 21.7 439 135 48.2 1.00 22 5.29 21.9 444 136 59 42.4 0.96 25 5.07 20.9 422 129 45.9 0.99 24 5.20 21.5 435 133 47.3 1.00 22 5.24 21.7 439 135 44.0 0.97 26 5.23 21.6 459 139 47.7 1.00 25 5.36 22.3 473 143 49.1 1.00 23 5.40 22.5 477 145 63 43.3 0.90 24 5.18 21.4 454 138 46.9 0.93 23 5.32 22.0 468 142 48.4 1.00 22 5.36 22.3 473 143 46.1 0.87 25 5.40 22.4 484 152 49.9 0.91 24 5.54 23.0 499 157 51.4 0.95 22 5.58 23.2 504 158 67 46.3 0.73 21 5.35 22.2 479 150 50.2 0.76 20 5.49 22.8 494 155 51.7 0.79 19 5.54 23.0 499 157 49.1 0.71 21 5.58 23.2 505 162 53.2 0.74 21 5.72 23.9 521 167 54.8 0.77 19 5.77 24.1 526 168 71 49.5 0.55 17 5.53 23.0 500 160 53.6 0.57 16 5.67 23.7 515 165 55.2 0.59 15 5.72 23.9 521 167 Amps = outdoor unit amps (comp.+fan) kW = Total system power 53.1 0.70 23 5.39 21.9 457 156 57.5 0.73 22 5.53 22.5 471 161 59.2 0.76 21 5.57 22.7 476 163 71 53.4 0.54 18 5.34 21.7 453 155 57.9 0.56 17 5.48 22.3 467 160 59.6 0.59 16 5.53 22.5 471 161 115ºF Expanded Cooling Data — GSX130601B* / CA*F4961*6A* (cont.) 17 18 www.goodmanmfg.com 54.7 0.75 25 4.00 15.5 230 99 56.3 0.78 23 4.03 15.7 233 100 56.6 0.79 21 4.06 15.8 235 101 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR 59 53.8 0.66 22 3.97 15.4 228 98 55.4 0.69 20 4.00 15.5 230 99 55.6 0.70 18 4.03 15.7 233 100 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR Airflow 56.3 0.67 23 4.09 15.9 248 105 58.0 0.70 21 4.12 16.1 250 106 58.3 0.71 19 4.15 16.2 253 107 63 55.7 0.55 19 4.05 15.8 245 104 57.4 0.57 17 4.09 15.9 248 105 57.7 0.58 15 4.12 16.0 250 106 60.9 0.50 19 4.22 16.4 262 115 62.7 0.53 17 4.25 16.6 264 116 63.1 0.54 16 4.28 16.7 267 117 67 61.0 0.38 14 4.18 16.3 259 114 62.9 0.40 13 4.21 16.4 262 115 63.2 0.40 12 4.25 16.6 264 116 65.4 0.32 13 4.35 17.1 273 122 67.3 0.34 12 4.39 17.2 276 123 67.7 0.35 11 4.42 17.4 278 125 - 71 53.4 0.77 25 4.31 16.8 258 104 55.0 0.81 23 4.34 17.0 261 105 55.3 0.82 21 4.38 17.1 264 106 59 52.5 0.68 22 4.27 16.7 256 103 54.1 0.71 20 4.31 16.8 258 104 54.3 0.72 18 4.34 17.0 261 105 55.0 0.69 23 4.40 17.2 278 111 56.6 0.72 22 4.44 17.4 281 112 56.9 0.73 19 4.48 17.6 284 113 63 54.4 0.57 19 4.37 17.1 275 110 56.1 0.60 18 4.40 17.2 278 111 56.3 0.60 16 4.44 17.4 281 112 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 75 59.5 0.52 19 4.55 17.8 294 121 61.3 0.55 18 4.58 18.0 297 122 61.6 0.56 16 4.62 18.1 300 124 67 59.6 0.39 14 4.51 17.6 291 120 61.4 0.41 13 4.54 17.8 294 121 61.7 0.42 12 4.58 18.0 297 122 63.9 0.34 13 4.69 18.5 306 129 65.8 0.35 12 4.73 18.7 309 130 66.1 0.36 11 4.77 18.8 312 132 - 71 52.1 0.79 25 4.58 18.3 294 108 53.7 0.83 23 4.62 18.5 297 110 53.9 0.84 21 4.66 18.7 300 111 59 51.3 0.70 22 4.54 18.1 291 107 52.8 0.73 20 4.58 18.3 294 108 53.0 0.74 18 4.62 18.5 297 110 63 67 58.1 0.54 19 4.84 19.4 334 126 59.8 0.56 18 4.88 19.6 337 127 60.1 0.57 16 4.92 19.8 341 129 58.2 0.40 14 4.80 19.2 331 125 59.9 0.42 13 4.84 19.4 334 126 60.2 0.43 12 4.88 19.6 337 127 62.3 0.35 13 5.00 20.2 348 134 64.2 0.36 12 5.04 20.3 352 136 64.5 0.37 11 5.08 20.5 355 137 - 71 59 50.9 0.82 26 4.82 19.6 335 114 52.4 0.86 24 4.86 19.8 338 115 52.6 0.87 21 4.90 20.0 341 116 50.0 0.72 22 4.78 19.4 331 113 51.5 0.75 20 4.82 19.6 335 114 51.8 0.77 18 4.86 19.8 338 115 56.7 0.55 19 5.09 20.8 380 132 58.4 0.58 18 5.14 21.0 384 134 58.7 0.59 16 5.18 21.2 388 135 52.4 0.73 23 4.93 20.1 360 121 53.9 0.77 22 4.97 20.3 364 122 54.2 0.78 19 5.01 20.5 367 124 67 56.8 0.42 14 5.05 20.6 377 131 58.5 0.44 13 5.09 20.8 380 132 58.8 0.44 12 5.13 21.0 384 134 63 51.8 0.60 19 4.89 19.9 357 120 53.4 0.63 18 4.93 20.1 360 121 53.6 0.64 16 4.97 20.3 364 122 Shaded area reflects ACCA (TVA) conditions 53.7 0.71 23 4.68 18.8 316 115 55.3 0.74 22 4.72 18.9 320 117 55.5 0.75 19 4.76 19.1 323 118 53.1 0.58 19 4.64 18.6 313 114 54.7 0.61 18 4.68 18.8 316 115 55.0 0.62 16 4.72 18.9 319 117 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 60.8 0.36 13 5.26 21.6 397 141 62.6 0.37 12 5.31 21.8 401 142 63.0 0.38 11 5.35 22.0 405 144 - 71 48.3 0.85 25 5.03 20.9 377 119 49.8 0.89 23 5.07 21.1 380 121 50.0 0.90 21 5.11 21.3 384 122 59 47.5 0.75 22 4.99 20.7 373 118 48.9 0.78 20 5.03 20.9 377 119 49.2 0.79 18 5.07 21.1 380 121 63 49.7 0.76 23 5.14 21.4 405 127 51.2 0.80 21 5.18 21.6 409 128 51.5 0.81 19 5.23 21.8 413 130 49.2 0.62 19 5.10 21.2 401 126 50.7 0.65 17 5.14 21.4 405 127 51.0 0.66 16 5.18 21.6 409 128 67 53.8 0.57 19 5.31 22.2 428 139 55.5 0.60 18 5.36 22.4 432 140 55.7 0.61 16 5.40 22.6 437 141 53.9 0.43 14 5.27 21.9 424 137 55.6 0.45 13 5.31 22.2 428 139 55.8 0.46 12 5.36 22.4 432 140 105 44.7 0.86 23 5.20 22.2 416 124 46.1 0.90 22 5.25 22.4 420 125 46.3 0.91 19 5.29 22.6 424 126 59 44.0 0.75 20 5.16 22.0 412 122 45.3 0.79 19 5.20 22.2 416 124 45.5 0.80 17 5.25 22.4 420 125 63 46.1 0.77 22 5.32 22.7 448 131 47.5 0.80 20 5.37 22.9 452 133 47.7 0.81 18 5.41 23.2 457 134 45.6 0.63 18 5.28 22.5 443 130 47.0 0.66 16 5.32 22.7 448 131 47.2 0.67 15 5.37 22.9 452 133 67 49.9 0.58 18 5.50 23.5 473 143 51.4 0.61 16 5.55 23.7 478 145 51.6 0.62 15 5.59 24.0 482 146 50.0 0.44 13 5.45 23.3 468 142 51.5 0.46 12 5.50 23.5 473 143 51.7 0.46 11 5.55 23.7 477 145 53.5 0.37 12 5.69 24.4 493 153 55.1 0.39 11 5.74 24.7 498 154 55.4 0.40 10 5.78 24.9 503 156 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 57.8 0.37 13 5.49 23.0 446 148 59.5 0.39 12 5.54 23.2 451 149 59.8 0.39 11 5.59 23.5 455 151 - 71 115 Expanded Cooling Data — GSX130611**/CA*F4961*6D*+EEP SS-GSX13 SS-GSX13 www.goodmanmfg.com 56.6 0.86 30 4.07 15.8 235 101 58.3 0.90 28 4.10 16.0 237 102 58.6 0.91 25 4.13 16.1 240 103 MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR 59 55.6 0.82 28 4.03 15.7 233 100 57.3 0.86 26 4.07 15.8 235 101 57.6 0.87 23 4.10 16.0 237 102 MBh S/T ∆T kW 1500 Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2000 kW Amps HI PR LO PR Airflow 57.7 0.83 29 4.15 16.2 253 107 59.4 0.87 27 4.19 16.4 255 108 59.7 0.88 24 4.22 16.5 258 109 63 56.9 0.77 27 4.12 16.1 250 106 58.6 0.80 25 4.15 16.2 253 107 58.8 0.82 22 4.19 16.4 255 108 60.4 0.75 28 4.28 16.7 267 117 62.2 0.78 26 4.32 16.9 270 118 62.5 0.79 23 4.35 17.1 272 119 67 60.7 0.62 23 4.25 16.6 264 116 62.6 0.65 22 4.28 16.7 267 117 62.9 0.66 19 4.32 16.9 270 118 64.5 0.61 24 4.42 17.4 279 125 66.4 0.64 22 4.46 17.6 281 126 66.7 0.64 20 4.50 17.7 284 127 71 64.9 0.47 19 4.39 17.2 276 123 66.9 0.49 17 4.42 17.4 279 125 67.2 0.50 15 4.46 17.6 281 126 55.3 0.89 30 4.38 17.1 264 107 56.9 0.93 28 4.42 17.3 266 108 57.2 0.94 25 4.45 17.5 269 109 59 54.3 0.85 28 4.35 17.0 261 105 56.0 0.89 26 4.38 17.1 264 107 56.2 0.90 23 4.42 17.3 266 108 56.4 0.86 30 4.48 17.6 284 113 58.1 0.90 27 4.51 17.7 287 114 58.3 0.91 24 4.55 17.9 289 116 63 55.5 0.80 27 4.44 17.4 281 112 57.2 0.83 25 4.48 17.6 284 113 57.5 0.85 22 4.51 17.7 287 114 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 75 59.0 0.77 28 4.62 18.2 300 124 60.8 0.81 26 4.66 18.3 303 125 61.1 0.82 23 4.70 18.5 306 126 67 59.3 0.65 24 4.58 18.0 297 122 61.1 0.68 22 4.62 18.2 300 124 61.4 0.69 19 4.66 18.3 303 125 63.0 0.63 24 4.77 18.9 313 132 64.9 0.66 22 4.81 19.0 316 133 65.2 0.67 20 4.85 19.2 319 134 71 63.4 0.48 19 4.73 18.7 309 130 65.3 0.51 17 4.77 18.9 313 132 65.6 0.51 16 4.81 19.0 316 133 63 55.0 0.88 30 4.76 19.1 323 118 56.7 0.92 27 4.80 19.3 326 119 56.9 0.93 24 4.84 19.5 329 120 54.2 0.82 27 4.72 18.9 320 117 55.8 0.85 25 4.76 19.1 323 118 56.1 0.87 22 4.80 19.3 326 119 67 57.6 0.79 28 4.92 19.8 341 129 59.4 0.83 26 4.96 20.0 344 130 59.6 0.84 23 5.00 20.1 348 131 57.9 0.66 24 4.88 19.6 337 127 59.6 0.70 22 4.92 19.8 341 129 59.9 0.71 19 4.96 20.0 344 130 71 61.5 0.64 24 5.08 20.5 355 137 63.3 0.68 22 5.12 20.7 359 138 63.6 0.68 20 5.17 20.9 363 140 61.9 0.50 19 5.04 20.3 352 136 63.8 0.52 17 5.08 20.5 355 137 64.1 0.53 16 5.12 20.7 359 138 Shaded area reflects AHRI conditions 54.0 0.91 30 4.66 18.7 300 111 55.6 0.96 28 4.70 18.8 303 112 55.9 0.97 25 4.74 19.0 306 113 59 53.0 0.87 28 4.62 18.5 297 110 54.6 0.91 26 4.66 18.7 300 111 54.9 0.92 23 4.70 18.8 303 112 52.7 0.94 30 4.90 20.0 342 116 54.2 0.99 28 4.95 20.2 345 117 54.5 1.00 25 4.99 20.4 348 119 51.8 0.90 28 4.86 19.8 338 115 53.3 0.94 26 4.90 20.0 342 116 53.6 0.95 23 4.94 20.2 345 117 59 53.7 0.91 30 5.01 20.5 368 124 55.3 0.95 28 5.06 20.7 371 125 55.6 0.96 25 5.10 20.9 375 126 52.9 0.84 27 4.97 20.3 364 122 54.5 0.88 25 5.01 20.5 368 124 54.7 0.89 23 5.06 20.7 371 125 63 56.2 0.82 28 5.18 21.2 388 135 57.9 0.86 26 5.22 21.4 392 136 58.2 0.87 23 5.27 21.6 396 138 56.5 0.69 24 5.14 21.0 384 134 58.2 0.72 22 5.18 21.2 388 135 58.5 0.73 20 5.22 21.4 392 136 67 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 60.0 0.66 24 5.35 22.0 405 144 61.8 0.70 23 5.40 22.2 409 145 62.1 0.71 20 5.45 22.4 413 147 71 60.4 0.51 19 5.31 21.8 401 142 62.2 0.54 18 5.35 22.0 405 144 62.5 0.54 16 5.40 22.2 409 145 50.0 0.98 30 5.11 21.3 384 122 51.5 1.00 27 5.16 21.5 388 123 51.8 1.00 24 5.20 21.7 392 124 59 49.2 0.93 28 5.07 21.1 380 121 50.6 1.00 27 5.11 21.3 384 122 50.9 1.00 23 5.16 21.5 388 123 63 51.0 0.94 29 5.23 21.8 414 130 52.5 0.99 27 5.27 22.0 418 131 52.8 1.00 24 5.32 22.2 422 132 50.2 0.87 27 5.18 21.6 409 128 51.7 0.92 25 5.23 21.8 414 130 52.0 0.93 22 5.27 22.0 418 131 67 53.4 0.85 28 5.40 22.6 437 142 55.0 0.89 26 5.45 22.8 441 143 55.3 0.90 23 5.49 23.0 445 144 53.7 0.71 23 5.36 22.4 432 140 55.3 0.75 22 5.40 22.6 437 142 55.6 0.76 19 5.45 22.8 441 143 105 46.3 0.98 28 5.29 22.6 425 126 47.7 1.00 25 5.34 22.8 429 127 48.0 1.00 22 5.38 23.0 433 129 59 45.5 0.94 26 5.25 22.4 420 125 46.9 1.00 25 5.29 22.6 425 126 47.1 1.00 22 5.34 22.8 429 127 63 47.2 0.95 28 5.41 23.2 457 134 48.7 1.00 25 5.46 23.4 461 135 48.9 1.00 22 5.50 23.6 466 137 46.5 0.88 25 5.37 22.9 452 133 47.9 0.92 23 5.41 23.2 457 134 48.2 0.94 21 5.46 23.4 461 135 67 49.5 0.86 26 5.59 24.0 482 146 51.0 0.90 24 5.64 24.2 487 148 51.2 0.91 21 5.69 24.4 492 149 49.7 0.72 22 5.55 23.7 478 145 51.2 0.75 20 5.59 24.0 482 146 51.5 0.76 18 5.64 24.2 487 148 52.8 0.70 23 5.79 24.9 503 156 54.4 0.73 21 5.84 25.1 508 157 54.6 0.74 19 5.89 25.4 513 159 71 53.2 0.54 17 5.74 24.7 498 154 54.7 0.56 16 5.79 24.9 503 156 55.0 0.57 14 5.84 25.1 508 157 Amps = outdoor unit amps (comp.+fan) kW = Total system power 57.0 0.69 24 5.59 23.5 455 151 58.7 0.72 22 5.63 23.7 460 152 59.0 0.73 20 5.68 23.9 465 154 71 57.4 0.53 19 5.54 23.2 451 149 59.1 0.56 17 5.59 23.5 455 151 59.4 0.56 15 5.63 23.7 460 152 115 Expanded Cooling Data — GSX130611**/CA*F4961*6D*+EEP (cont.) 19 20 www.goodmanmfg.com YL T2 L2 T1 L1 1 SR BL IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR 2 5 BK BK BR PU BK IO C MAIN R AUX BL S BL/PK COMP BL/PK BL/PK Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. YL RD CONTROL BOX C RD RCCF F HERM RD SA (IF USED) NOTE 2 BR RD RD YL YL YL BL CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR HPS ----------- HIGH PRESSURE SWITCH IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE L1 C M AI N X AU HPS CM IO IO Y SR S AI N R COMP X AU M 5 C 2 F H 1 ⚡ USE N.E.C. CLASS 2 WIRE SC C C (IF USED) SA RCCF OUTDOOR POWER SUPPLY SEE RATING PLATE T2 0140R00258-B NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. T1 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. YL EQUIPMENT GROUND RD PU RD RD ⚠ WARNING HPS C L2 T2 T1 L1 BK BK BK SC C BL NOTE 1 COLOR CODE BK --------------- BLACK BL --------------- BLUE BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL ---------------- YELLOW Y BL/PK ALTERNATE DOUBLE POLE CONTACTOR ONLY LVJB C L2 Wiring Diagram— GSX130(181E*/241E*/301L*) SS-GSX13 SS-GSX13 www.goodmanmfg.com YL T2 L2 T1 L1 1 SR BL IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR 2 5 BK BK BR PU BK C R AUX MAIN COMP YL BL S Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. YL RD CONTROL BOX T1 RD YL RCCF RD SA (IF USED) NOTE 2 RD YL C BL RD BR F RD CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE SEE NOTE 1 L1 C CM IO IO Y M AI N X AU SR S 2 SEE NOTE 1 C R COMP X AU M AI N 5 C F H 1 ⚡ USE N.E.C. CLASS 2 WIRE SC C (IF USED) SA RCCF 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. NOTES: C T1 OUTDOOR POWER SUPPLY SEE RATING PLATE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. EQUIPMENT GROUND SEE NOTE 3 H PU RD RD ⚠ WARNING C L2 T2 L1 BK BK BK SC C BL COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL ---------------- YELLOW Y YL ALTERNATE DOUBLE POLE CONTACTOR ONLY LVJB C L2 0140R00015P-C T2 Wiring Diagram— GSX130(30-61)1** 21 Dimensions Dimensions Model W D W” D” H” GSX130181E* 23 23 25¾ GSX130241E* 26 26 27½ GSX130301B* 26 26 27½ GSX130361E* 26 26 27½ GSX130421B* 29 29 36¼ GSX130481B* 29 29 36¼ GSX130601B* 29 29 40 GSX130611A* 35½ 35½ 38¼ H Goodman Manufacturing Company, L.P. GSX13 Accessories Model # Description ABK-20 ABK-21 ASC-01 CSR-U-1 CSR-U-2 CSR-U-3 FSK01A¹ LSK02A² 0130R00000S LAKT01A TX2N4A² TX3N4² TX5N4² Anchor Bracket Kit ^ Anchor Bracket Kit ^ Anti-Short Cycle Kit Hard-start Kit Hard-start Kit Hard-start Kit Freeze Protection Kit Liquid Line Solenoid Kit Low-Pressure Switch Kit Low-Ambient Kit TXV Kit TXV Kit TXV Kit ^ ¹ ² GSX13 018E* X X X X X X X X GSX13 GSX13 024E*/F* 030B*/L* GSX13 036E* EGSX13 042** GSX13 048** GSX13 060** GSX13 061** X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Field-installed, non-bleed, expansion valve kit: Condensing units and heat pumps with reciprocating or rotary compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. All AHRI system ratings are accessible in the System Configurator tool via PartnerLink. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2020 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 22 www.goodmanmfg.com SS-GSX13 ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات