Parameter List for Orientation Control. Mitsubishi Electric FR-A7AP, FR-A740-0.4K
Add to My manuals42 Pages
The Mitsubishi Electric FR-A740-0.4K is a versatile and reliable frequency inverter that offers precise control of AC induction motors. With its compact design and easy-to-use interface, it's ideal for a wide range of industrial applications, including pumps, fans, and conveyors. The FR-A740-0.4K boasts advanced features such as orientation control, encoder feedback control, and vector control, making it suitable for even the most demanding applications.
advertisement
![Parameter List for Orientation Control. Mitsubishi Electric FR-A7AP, FR-A740-0.4K | Manualzz Parameter List for Orientation Control. Mitsubishi Electric FR-A7AP, FR-A740-0.4K | Manualzz](http://s2.manualzz.com/store/data/059136511_1-e6b679499946a5d4cce72f48f599e3b9-360x466.png)
ORIENTATION CONTROL
3.3
Parameter List for Orientation Control
Fitting the FR-A7AP adds the following parameters for orientation control.
Refer to the inverter manual (applied) for details of parameter.
Parameter
Number
358
359
360
361
362
363
364
365
366
369
350
351
352
353
354
355
356
357
376
393
396
397
398
399
Name Setting Range Increments Initial Value
Stop position command selection
Orientation speed
Creep speed
Creep switchover position
Position loop switchover position
DC injection brake start position
Internal stop position command
In-position zone
Servo torque selection
Encoder rotation direction
16 bit data selection
Position shift
Orientation position loop gain
Completion signal output delay time
Encoder stop check time
Orientation end time
Double check time
Number of encoder pulses
Encoder signal loss detection enable/disable selection
Orientation selection
Orientation speed gain (P term)
Orientation speed integral time
Orientation speed gain (D term)
Orientation deceleration ratio
0, 1, 9999
0 to 30Hz
0 to 10Hz
0 to 16383 *
0 to 8191
0 to 255
0 to 16383 *
0 to 255
0 to 13
0, 1
0 to 127
0 to 16383 *
0.1 to 10
0 to 5s
0 to 5s
0 to 60s, 9999
0 to 5s, 9999
0 to 4096
0, 1
0, 1, 2
0 to 1000
0 to 20s
0 to 100
0 to 1000
1
0.01Hz
0.01Hz
1
1
1
1
1
1
1
1
1
0.1
0.1s
0.1s
1s
0.1s
1
1
1
1
0.001
0.1
1
* When an operation panel (FR-DU07) is used, the maximum setting is 9999. When a parameter unit is used, up to the maximum value within the setting range can be set.
0
0
1
1
1
0.5s
0.5s
9999
9999
1024
9999
2Hz
0.5Hz
511
96
5
0
5
0
0
60
0.333
1
20
22
advertisement
Related manuals
advertisement
Table of contents
- 6 Unpacking and Product Confirmation
- 6 Packing confirmation
- 7 SERIAL number check
- 8 Parts
- 9 Pre-Installation Instructions
- 10 Installation Procedure
- 12 Switches
- 14 Wiring
- 18 Encoder Cable
- 20 Encoder
- 21 Parameter for Encoder
- 23 Wiring Example
- 25 Terminals
- 27 Parameter List for Orientation Control
- 28 Specifications
- 29 Wiring Examples
- 30 Terminals
- 31 Encoder Feedback Control Parameter List
- 33 Wiring Examples
- 37 Terminals
- 38 Vector Control Extended Parameter List
- 41 Specifications