Backplane Traffic Monitoring. Cisco Catalyst 6800ia Switch , Catalyst 6503-E Switch , Catalyst 6807-XL Switch , Catalyst 6504-E Switch , Catalyst 6840-X Switch , Catalyst 6506-E Switch , Catalyst 6880-X Switch , EOL Details, Catalyst 6509-E Switch , Catalyst C6816-X-LE Switch  | Manualzz

C H A P T E R

57

Backplane Traffic Monitoring

Prerequisites for Backplane Traffic Monitoring, page 57-1

Restrictions for Backplane Traffic Monitoring, page 57-2

Information About Traffic Monitoring, page 57-2

Default Settings for Backplane Traffic Monitoring, page 57-2

How to Configure Backplane Traffic Monitoring, page 57-3

Note •

For complete syntax and usage information for the commands used in this chapter, see these publications: http://www.cisco.com/en/US/products/ps11846/prod_command_reference_list.html

Cisco IOS Release 15.4SY supports only Ethernet interfaces. Cisco IOS Release 15.4SY does not support any WAN features or commands.

Tip For additional information about Cisco Catalyst 6500 Series Switches (including configuration examples and troubleshooting information), see the documents listed on this page: http://www.cisco.com/en/US/products/hw/switches/ps708/tsd_products_support_series_home.html

Participate in the Technical Documentation Ideas forum

Prerequisites for Backplane Traffic Monitoring

None.

Supervisor Engine 2T Software Configuration Guide, Release 15.4SY

57-1

Chapter 57 Backplane Traffic Monitoring

Restrictions for Backplane Traffic Monitoring

Restrictions for Backplane Traffic Monitoring

The syslog message buffer is limited in size. To reduce false alarms and the number of syslog messages, use the following guidelines:

• Traffic can occur in bursts. If a small number of bursts occur in a monitoring interval, it does not represent a capacity overload issue for the system; the hardware buffers are able to absorb the effects and not cause packet drops. For an example, if you set a monitoring interval to 10 seconds and the threshold to 80 percent, there are a total of 10 traffic utilization readings. Assume only 2 of the readings reached 90 percent and the other 8 readings are 20 percent. If the peak threshold of

90 percent is used to compare with the threshold, an unwanted warning syslog message is generated.

It is better to use the average 34 percent of the 10 readings to compare with the threshold and not generate warning messages in this case. If the peak value comparison is really needed, you can set the interval to 1 second. Setting the interval to 1 second compares the reading directly with the threshold.

• The number of syslog messages that generate syslog messages are from below the threshold and above the threshold.

Information About Traffic Monitoring

Backplane Traffic Monitoring can monitor the backplane and fabric-channel traffic utilization at a configured interval and threshold.

Traffic monitoring allows the switch to monitor the backplane and fabric channel traffic utilization at a configured interval and threshold. Syslog messages are generated when the traffic utilization is above or below the configured threshold. The following examples show several types of syslog messages:

00:08:03: %TRAFFIC_UTIL-SP-4-MONITOR_BACKPLANE_REACH_THR: Backplane traffic utilization is 26%, reached threshold(20%) within 10 second interval

00:08:13: %TRAFFIC_UTIL-SP-4-MONITOR_BACKPLANE_BELOW_THR: Backplane traffic utilization is 18%, below threshold(20%) within 10 second interval

00:08:44: %TRAFFIC_UTIL-SP-4-MONITOR_FABRIC_IG_REACH_THR: Module 1, Channel 0 ingress traffic utilization is 5%, reached threshold(3%) within 30 second interval

00:08:44: %TRAFFIC_UTIL-SP-4-MONITOR_FABRIC_EG_REACH_THR: Module 1, Channel

0 egress traffic utilization is 5%, reached threshold(3%) within 30 second interval

00:09:14: %TRAFFIC_UTIL-SP-4-MONITOR_FABRIC_IG_BELOW_THR: Module 1, Channel 0 ingress traffic utilization is 1%, below threshold(3%) within 30 second interval

00:09:14: %TRAFFIC_UTIL-SP-4-MONITOR_FABRIC_EG_BELOW_THR: Module 1, Channel

0 egress traffic utilization is 1%, below threshold(3%) within 30 second interval

Default Settings for Backplane Traffic Monitoring

The default threshold is 80 percent.

Traffic monitor is off by default.

57-2

Supervisor Engine 2T Software Configuration Guide, Release 15.4SY

Chapter 57 Backplane Traffic Monitoring

How to Configure Backplane Traffic Monitoring

How to Configure Backplane Traffic Monitoring

To configure the Backplane Traffic Monitoring feature, perform one or more of the following tasks:

Command

Router(config)# monitor traffic-util backplane interval interval threshold percentage

Router(config)# monitor traffic-util fabric module

{ mod-num | all } { channel { 0 | 1 | both }} { direction

{ egress | ingress | both }} [ interval interval threshold percentage ]

Router(config)# monitor traffic-util fabric logging interval second

Router(config)# monitor traffic-util backplane logging interval second

Router# show catalyst6000 traffic-meter

Purpose

Configures the backplane utilization traffic monitoring.

Configures the fabric channel utilization traffic monitoring.

Configures the fabric channel utilization traffic monitor

SYSLOG interval when the traffic utilization is in the crossed state.

Configures the traffic monitor backplane SYSLOG interval when the traffic utilization is in the crossed state.

Displays the percentage of the backplane (shared bus) utilization and traffic monitor status information.

When configuring a range of interfaces, you can enter the mod-num as a list or a range. Separate each entry with a comma and each range with a hyphen (-). For example, 1,3,5-9,12.

The following example shows how to enable backplane traffic utilization monitoring:

Router(config)# monitor traffic-util backplane logging interval 50 threshold 100

The following example shows how to disable backplane traffic utilization monitoring:

Router(config)# no monitor traffic-util backplane

The following example shows how to specify the fabric channel traffic utilization monitor interval and threshold for a fabric channel on a specific module:

Router(config)# monitor traffic-util fabric module 8 channel both direction both interval

50 threshold 60

The following example shows how to specify the fabric channel traffic utilization monitor threshold for a specific fabric channel and for egress traffic only:

Router(config)# monitor traffic-util fabric module 6 channel 0 direction egress interval

100 threshold 90

Tip For additional information about Cisco Catalyst 6500 Series Switches (including configuration examples and troubleshooting information), see the documents listed on this page: http://www.cisco.com/en/US/products/hw/switches/ps708/tsd_products_support_series_home.html

Participate in the Technical Documentation Ideas forum

Supervisor Engine 2T Software Configuration Guide, Release 15.4SY

57-3

How to Configure Backplane Traffic Monitoring

Chapter 57 Backplane Traffic Monitoring

57-4

Supervisor Engine 2T Software Configuration Guide, Release 15.4SY

advertisement

Key Features

  • High port density, with up to 48 Gigabit Ethernet ports or 24 10 Gigabit Ethernet ports per switch
  • Advanced QoS features, including traffic shaping, priority queuing, and congestion management
  • Modular architecture, allowing for easy expansion of ports and features as needed
  • Layer 2 and Layer 3 switching, providing flexibility for a wide range of network topologies
  • Comprehensive security features, including access control lists, firewall, and intrusion detection
  • Network management tools, including SNMP, Telnet, and CLI, for easy configuration and monitoring

Related manuals

Frequently Answers and Questions

What are the key benefits of using Cisco Catalyst 6800 Series Switches?
The key benefits of using Cisco Catalyst 6800 Series Switches include high port density, advanced QoS features, modular architecture, Layer 2 and Layer 3 switching, comprehensive security features, and network management tools.
What types of networks are Cisco Catalyst 6800 Series Switches ideal for?
Cisco Catalyst 6800 Series Switches are ideal for supporting a wide variety of applications, including voice, video, and data, in enterprise and data center networks.
How do I configure a Cisco Catalyst 6800 Series Switch?
You can configure a Cisco Catalyst 6800 Series Switch using SNMP, Telnet, or the CLI.

advertisement

Table of contents