Changing item names. Shimadzu GC-2014

Add to My manuals
318 Pages

advertisement

Changing item names. Shimadzu GC-2014 | Manualzz

6 Basic Key Operation

6.3 Basic Key Operations

6.3.5

Changing item names

Customize file names and other names with alphanumeric characters and symbols. Change the name using the following procedure:

(1) Move the cursor to an item to be changed using the [ △ ] and [ ▽ ] keys.

(2) Move the cursor to a character to be changed using the [   ] and [   ] keys.

(3) Input a character as described in the following section on entering characters. The character input procedure described below.

(4) Press the [ENTER] key to validate the input.

(5) Repeat steps (2) to (4) to enter a name.

(6) Press the [CE] key to delete one character at the cursor’s current position.

Fig. 6.3.5

 

GC-2014 75

6 Basic Key Operation

6.3 Basic Key Operations

Q

Entering characters

Initially, the character input screen is in the upper case mode. Press [LowerChr] (PF menu) to select the lower case mode. Press [NumerChr] (PF menu) to select the numeric mode.

Alphabetic mode (upper case/lower case)

8

9

0

6

7

Key

1

2

3

4

5

Toggled characters

A/a → B/b → C/c → A/a → ・ ・ ・

D/d → E/e → F/f → F/f → ・ ・ ・

G/g → H/h → I/i → G/g → ・ ・ ・

J/j → K/k → L/l → J/j → ・ ・ ・

M/m → N/n → O/o → M/m → ・ ・ ・

P/p → Q/q → R/r → P/p → ・ ・ ・

S/s → T/t → U/u → S/s → ・ ・ ・

V/v → W/w → X/x → V/v → ・ ・ ・

Y/y → Z/z → Y/y → ・ ・ ・

0 → 1 → 2 → 3 → 4 → 5 → 6 → 7 → 8 → 9 → 0 → ・ ・ ・

(blank) → . → , → + → - → * → / → # → $ → % → & → (blank) → ・ ・ ・

& → % → $ → # → / → * → - → + → , → . → (blank) → & → ・ ・ ・

Numeric mode

Press the [0] to [9] keys to input numbers “0” to “9”.

Press the [-] and [ ・ ] keys to toggle the symbols.

76 GC-2014

advertisement

Key Features

  • Dual-column packed FID analysis
  • Single-column packed FID analysis
  • Packed TCD analysis
  • Packed analysis using the single DET
  • Dual FID analysis with detector adapter with purge
  • Dual FID analysis with makeup gas flow controller
  • Capillary TCD analysis
  • Single DET analysis

Related manuals

Frequently Answers and Questions

What types of analysis can the GC-2014 perform?
The GC-2014 can perform dual-column packed FID analysis, single-column packed FID analysis, packed TCD analysis, packed analysis using the single DET, dual FID analysis with either a detector adapter with purge or a makeup gas flow controller, capillary TCD analysis, and single DET analysis.
What types of columns can be used with the GC-2014?
The GC-2014 can be used with both packed and capillary columns.
What types of detectors can be used with the GC-2014?
The GC-2014 can be used with FID, TCD, and single DET detectors.

advertisement