7.3.9

Chart Object

The chart object is used to display values of connected array tags.

Settings for the chart object are available from the General ribbon tab while the object is selected:

Chart Settings Group

Parameter

Edit Series

Chart Types

Header

3D View

Description

Add, remove and edit the current series for this chart

Choose chart type. Available types are:

Area

Area Horizontal

Bar

Bar Join

Donut

Histogram

Kagi

Line

Line Fast

Line Horizontal

Line Point

Pie

Points

Radar

Set the name that is displayed above the chart

Set a 3D look and feel for the chart

X Axis Settings Group

Parameter

Visible

Grid Visible

Automatic

Minimum

Maximum

Description

Set the visibility of the X axis

Set the visibility of the X axis grid lines.

Automatically calculates the minimum and maximum

X axis values. Overrides the Minimum and Maximum properties

Set the minimum value of the X axis. If automatic is set, this value is ignored

Set the maximum value of the X axis. If automatic is set, this value is ignored

Objects

Beijer Electronics, MAEN831H

186

Y1 Axis Settings Group

Parameter

Visible

Grid Visible

Automatic

Minimum

Maximum

Description

Set the visibility of the Y1 axis

Set the visibility of the Y1 axis grid lines.

Automatically calculates the minimum and maximum

Y1 axis values. Overrides the Minimum and Maximum properties.

Set the minimum value of the Y1 axis. If automatic is set, this value is ignored.

Set the maximum value of the Y1 axis. If automatic is set, this value is ignored. When using charts with visible labels on curves the maximum value is extended to make room for label.

Y2 Axis Settings Group

Parameter

Visible

Grid Visible

Automatic

Minimum

Maximum

Description

Set the visibility of the Y2 axis

Set the visibility of the Y2 axis grid lines.

Automatically calculates the minimum and maximum

Y2 axis values. Overrides the Minimum and Maximum properties.

Set the minimum value of the Y2 axis. If automatic is set, this value is ignored.

Set the maximum value of the Y2 axis. If automatic is set, this value is ignored. When using charts with visible labels on curves the maximum value is extended to make room for label.

Style Group

Style

Parameter Description

Set the style of the chart

Visibility Group

Parameter

Scale

Transparent

Header

Legend

Description

Set the visibility of the scale

Make the chart transparent

Set the header visibility

Set the legend visibility

Objects

Beijer Electronics, MAEN831H

187

The Edit Series Dialog

Clicking the

Edit Series

control in the Chart Settings Group will open the Edit

Series Dialog. The Edit Series Dialog contains the following settings:

Name

Parameter

X Tag

Y Tag

Size

Labels

Color

Thickness

Axis Type

Description

The name of the Series, as shown in the legend in the chart.

The X Tag values.

The tag must be an array tag.

The number of elements shown will be the lowest common denominator of the X Tag array size and the Y Tag array size.

Optional: The Y Tag values for the chart.

The tag must be an array tag.

If this value is not chosen, the X Tag Values will still be visible and the Y Axis will be set automatically. The number of elements shown will be the lowest common denominator of the X Tag array size and the Y Tag array size.

Optional: The number of elements in the tag arrays. This property overrides the sizes of the X Tag array size and Y

Tag array size. If this value is not set, the lowest common denominator of the X Tags array size and the Y Tags array size will be chosen as size.

Set a label for each point in the chart. There is one label for each available tag value.

Choose the color of the series.

Set the thickness of the series. This applies for the chart types Line, Line Fast, Line Horizontal and Line Point.

Select the Y Axis that this series will use.

Objects

Note:

Chart objects with large arrays where values are frequently changing may affect performance.

Related information

Array Tags

Beijer Electronics, MAEN831H

188

7.3.10

Database Viewer Object

The Database Viewer can be used to display database contents in runtime.

For operator panel projects, only databases included in the current project are available. For PC targets, it is possible to access databases from anywhere in the network environment.

Settings for the database viewer object are available from the General ribbon tab while the object is selected:

Settings Group

Parameter

Show Controls

Database

Description

When the box is checked, the user is able to select database and database table in runtime

Path to database to be loaded automatically in runtime*

Table Name

Browse Data Table

The table in the selected database to be loaded automatically in runtime*

Opens a browse dialog for selection of database and database table in design time. The path and table name will be added to the

Database

and

Table Name

fields.

* If the entered database or table does not exist or is not valid, an empty database viewer is displayed in runtime.

Note:

Simulation of the object on the development PC is supported only for PC targets.

Related information

Database

Objects

Beijer Electronics, MAEN831H

189

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents