7. Set the PICC Operating Parameter. Advanced Card Systems V5MACR1222U, ACR1222 U
Advanced Card Systems V5MACR1222U is a versatile and feature-rich device that seamlessly integrates contact and contactless smart card technologies. With its dual-interface capabilities, it supports a wide range of applications, including secure authentication, financial transactions, loyalty programs, and access control systems.
광고
광고
7.
Set the PICC Operating Parameter
This command is used to control the PICC Operating Parameter of the reader.
Read the existing status:
Command = {20 00}
Response = {E1 00 00 00 01 “PICC Operating Parameter”}
Setting the PICC Operating Parameter:
Command = {20 01 “CMD”}
Response = {E1 00 00 00 01 “PICC Operating Parameter”}
PICC Operating Parameter. Default Value = FF
CMD
Bit0
Parameter
ISO14443 Type A
#To detect the MIFARE
Tags, the Auto ATS
Generation must be disabled first.
Description Option
1 = Detect
0 = Skip
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
ISO14443 Type B
Topaz
FeliCa 212K
FeliCa 424K
Polling Interval
Auto ATS Generation
Auto PICC Polling
The Tag Types to be detected during
PICC Polling.
To set the time interval between successive PICC Polling.
To issue ATS Request whenever an
ISO14443-4 Type A tag is activated
To enable the PICC Polling
1 = Detect
0 = Skip
1 = Detect
0 = Skip
1 = Detect
0 = Skip
1 = Detect
0 = Skip
1 = 250 ms
0 = 500 ms
1 = Enable
0 = Disable
1 = Enable
0 = Disable
Advanced Card Systems Ltd. `Page 24 of 46